Home
Adjustable Frequency Drivers
Contents
1. O e e amp 9 9 QUE OO Su 6 2 RO ien L e gt WK gt 4 ER d 9 gt dl Io dl b F3 gt H3 A DN o o o O O o o Y L 9 SH Y Je wa m lt W1 gt D1 gt Right Side Front Left Side Voltage Amps H1 H2 H3 D1 W1 W2 R1Dia 540 675 Vdc 1370 4140 36 38 1 03 3437 1535 2937 787 043 SUR Em 924 26 873 390 746 200 11 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 265 7 9 Adjustable Freguency Drives LCX9000 Drives Approximate Dimensions in Inches mm Chassis Size CH72 2 1 EE gt
2. 5 9000 Drives Approximate Dimensions Inches mm AC Choke Dimensions Choke Types Catalog Number Frame Size Choke Type Catalog Number Frame Size Choke Type Voltage Range 380 500V Voltage Range 525 690V SPX2504 FR10 CHK0400 SPX 2005 FR10 CHK0261 SPX 300 4 CHK0520 SPX 2505 CHK0400 SPX3504 CHK0520 SPX 3005 CHK0400 SPX 4004 FR11 2 x CHK0400 SPX 4005 FR11 CHK0520 SPX 5004 2 x CHK0400 SPX 4505 CHK0520 5 550 4 2 x CHK0400 SPX 500 5 2 CHK0400 SPX 600 4 FR12 2 x CHK0520 SPX5505 FR12 2 x CHK0400 SPX 650 4 2 x CHK0520 SPX 600 5 2 x CHK0400 SPK 7004 2 CHK0520 SPX 700 5 2 x CHK0400 SPX 800 4 FR13 2 x CHK0400 SPX 800 5 FR13 2 x CHK0400 SPX 900 4 3 x CHK0520 SPX 900 5 2 x CHK0400 SPX H10 4 3 x CHK0520 SPX H105 2 x CHK0400 SPX 12 4 FR14 4 x CHK0520 SPX H135 FR14 4 x CHK0400 SPX H16 4 6 x CHK0400 SPX H155 6 x CHK0400 CHK0520 1 p K 9 lol 191 jo El A 650 650 165 165 24 6 8 03 204 1 69 19 57 i 43 497 gt n 1 n 1 6 1 0 Ex Ami r 1 FEM m 79 1257 20 15 71 446 1 58 399 3 03 40 7 77 Y 3 3 3 I LJ 8 Tp 21 9 U im T U
3. 85 485 DOC 2 C D mm x 123 4 128 1 A 8 ZZ j CZE oN CI Z CSD CL 7 0 Cr DOC 2 C OCZ O Q GE ____ Y Y Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 7 Adjustable Frequency Drives PowerXL DC1 DA1 Series Adjustable Frequency AC Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Contents E Description Page ary z PowerXL DC1 Series Adjustable Frequency AC Drives 5 ENE Catalog Number Selection V6 T2 9 EE Product Selection V6 T2 10 m Accessories V6 T2 14 M e Technical Data and Specifications V6 T2 15 Dimensions V6 T2 19 asa us meu ca RR 9 s Product Description Features Eaton s PowerXL M DC1 and DA1 variable frequency drives are the next generation of drives specifically engineered for today s machinery applications The DC1 is compact with only 14 basic parameters SmartWire DT connectivity and outstanding ease of mounting and installation The DC1 is perfect for quick commissioning and is
4. w1 R2 FW o BEM o E H1 H3 Mg U 8 ome c9 SW t 545 e elle le 6 H2 usd lt D1 gt W3 R1 Bottom Side Front Voltage Amps H1 H2 H3 D1 W1 w2 W3 R1 Dia R2 Dia 540 675 Vde 460 730 26 50 2 0 23 23 14 69 9 69 3 94 5 91 0 55 0 51 710 930 Vde 375 507 673 53 590 373 246 100 150 14 13 Chassis Size CH63 ojo Bottom Right Side Left Side Weight Voltage Amps H1 H2 H3 01 W1 W2 R1 Dia Lbs kg 380 500 820 1030 36 36 0 91 34 39 15 35 19 88 13 98 0 43 264 120 525 690 Vac 590 750 923 5 23 0 873 5 390 0 505 0 355 0 11 0 V6 T2 264 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 09 LCX9000 Drives Approximate Dimensions Inches mm Liquid Cooled Inverter with Mounting Bracket Chassis Size 64 90
5. V6 T2 74 Volume 6 Solid State Motor Control Adjustable Freguency Drives 5 9000 Drives SVX9000 Enclosed Drives SVX9000 Enclosed Drives Product Description Standard Enclosed covers a wide range of the most commonly ordered options Pre engineering eliminates the lead time normally associated with customer specific options e Modified Standard Enclosed applies to specific customer requirements that vary from the standard enclosed offering such as the need for an additional indicating light or minor modifications to drawings Consult your Eaton representative for assistance in pricing and lead time Custom Engineered for those applications with more unique or complex requirements these are individually engineered to the customer s needs Consult your Eaton representative for assistance In pricing and lead time Contents Description SVX9000 Open Drives SVX9000 Enclosed Drives Product Identification Catalog Number Selection Product Selection Options Data Specifications Dimensions SVX9000 VFD Pump Panels Features e NEMA Type 1 IP21 or 12 IP54 enclosures Input voltage 208V 230 480V and 575V consult
6. lt w gt T I T z 0 d p H1 H Y Y rs w1 D1 Approximate Approximate Weight Shipping Weight H H1 w W1 D D1 Lbs kg Lbs kg 93 58 69 51 60 00 48 00 37 50 26 00 1700 771 1850 839 2376 9 1765 60 1524 0 1219 2 952 5 660 4 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 217 2 9000 Drives Approximate Dimensions Inches mm Enclosure Size 7 Adjustable Frequency Drives Cable Entry N 508 0 0 ded Y 2 00 Hinged Side 50 8 26 25 Door Clearance 10 00 666 8 at 90 254 0 4 00 101 6 Free Air Space Reguired 1 I With Circuit Breaker ee en Specifie D Operator Elements Door Handle 93 9 es optional 238 5 90 00 84 37 m m akan d GO 2 LA IHH O 4 Tup Latch o wo places Y Y lt 393 7 7 7 21 50 Front View 546 1 Side View Wenning Moles te8 8 Open
7. SVX9000 Drives 2 4 Size 5 sa ZK A A Ling RAA aces I A RR N T For Cable gt M C 5 B E APA Top View Front View Type 1 IP21 L 0 56 14 2 Dia Mounting I Y Holes F 4 ke 55 gt Side View B Bottom View 208 230V 75 100 480V 200 250 Front View NEMA Type 12 1 54 For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B 0 01 E1 G G1 H J K 40 0 1016 90 0 2286 21 3 541 36 0 914 250 51 108 2 73 84 4 2143 4 0 102 Max Approx Cable Entry Door Clearance Shipping Weight L M N P R S T U V RR Lbs kg 15 0 10 0 4 8 2 0 36 3 20 0 94 0 15 5 1275 579 381 254 122 51 921 508 2387 394 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 93 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm Size 5 1P AN A J mm E
8. 0 44 11 2 0 44 11 2 w1 Mounting 4 00 101 6 Minimum qud er 4 00 101 6 Minimum Minimum Air Space 0 65 Free Air Space Required J Minimum ir space 23 Free Air Space Required i i 4 Places D q Required Both Sides 4 Places __ PA N m Required Both Sides j Bl o Ka A F 7 e e H2 H H2 HA H3 e Y J Y lt WI gt E w gt 0 PE 7 Y lo e 01 lt D gt Approx Voltage hp hp Shipping Weight AC ly 1 H H1 H2 H3 H4 w W1 D D1 Lbs kg Three Phase 208V 30 50 40 60 52 00 50 00 48 35 72 00 71 19 30 92 29 30 16 78 2 34 230V 30 50 10 60 1320 8 1270 0 1228 1 1828 8 1808 2 785 4 744 2 426 2 59 4 480V 75 125 100 150 Single Phase 230V 25 40 52 00 50 00 48 35 72 00 71 19 30 92 29 30 16 78 2 34 1320 8 1270 0 1228 1 1828 8 1808 2 785 4 744 2 426 2 59 4 480V 40 60 Note Consult factory V6 T2 114 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Enclosure Box A NEMA Type 3R 0 44 11 2 Mounting Holes 4 Places Approx Approx Voltage hp hp Weight Shipping Weight AC lu 1 H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs k
9. 45 66 Hz input frequency Standard Setup adjustment provisions Output AC volts maximum Input voltage base Remote keypad display Standard Output frequency range 0 320 Hz Personal computer Standard Initial output current lh 250 for 2 seconds Operator control provisions Overload 1 minute 150 110 Drive mounted keypad display Standard Enclosure space heater Optiona Remote keypad display Standard Oversize enclosure Standard Conventional control elements Standard Output contactor Optiona Serial communications Optional Bypass motor starter Optiona 115 Vac control circuit Optional Listings UL cUL Speed setting inputs Protection Features Keypad Standard ncoming line fuses Optiona 0 10 potentiometer voltage signal Standard AC input circuit disconnect Optiona 4 20 mA Isolated Configurable Line reactors 3 Standard 4 20 mA Differential Configurable Phase rotation insensitive Standard Analog outputs EMI filter Standard Speed frequency Standard nput phase loss protection Standard Torque load current Programmable nput overvoltage protection Standard Motor voltage Programmable Line surge protection Optional Kilowatts Programmable Output short circuit protection Standard 0 10 signals Configurable w jumpers Output ground fault protection Standard 4 20 mA DC signals Standard Output phase protection Standard I
10. P A H2 lt H1 gt x H4 D1 H5 D f f D2 N Y E H3 gt H7 gt Dia B 1 Opening Wa FR4 to FR6 WA WS Im Y H8 gt l lt H6 gt 9 FR4 5 FR6 with Kit W1 W2 H1 H2 H3 H4 H5 D1 D2 Dia A 4 5 0 128 4 5 113 13 3 337 12 8 325 12 9 327 1 2 30 0 9 22 7 5 190 3 0 77 0 3 7 5 5 6 143 4 7 120 17 0 434 16 5 420 16 5 419 1 4 36 0 7 18 8 4 214 3 9 100 0 3 7 6 7 7 195 6 7 170 22 0 560 21 6 549 22 0 558 1 2 30 0 8 20 9 3 237 4 2 106 0 3 7 Flange Opening FR4 to FR6 W3 W4 w5 H6 H7 H8 H9 Dia B FR4 4 8 123 4 5 113 12 4 315 12 8 325 0 2 5 0 3 7 5 5 3 135 4 7 120 kani 16 2 410 16 5 420 0 2 5 0 3 7 6 7 3 185 6 7 170 6 2 157 21 2 539 21 6 549 0 3 7 0 2 5 0 3 7 V6 T2 146 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 5 SPX9000 Drives Approximate Dimensions in Inches mm Type 1 IP21 and Type 12 IP54 FR7 lt H1 gt E H2 gt 5 o ii W2 WI E A Y R2 R1 R2
11. OuarterTurn Latch of three places Y 30 00 gt 00 56 614 2 762 0 Mounting Holes five places Opening Bottom Cable Entry e 14 90 378 5 gt 10 50 18 75 4 25 266 7 476 3 1079 5 75 H 700 146 1 1778 175 44 5 24 45 621 0 28 05 lt 712 5 Bottom View CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 8 9000 Drives Approximate Dimensions in Inches mm Enclosure Size 8 200 250 hp and 150 200 hp Ih 480V 125 200 hp I and 100 150 hp Ih 575V 1 25 31 00 31 8 17 7874 gt j 8 25 7 209 6 Cable Entry t TTE T two places Top View 4 00 101 6 Minimum Free Air Space Required A LO o A e YT mm IL T Drive 228601 2374 9 IUD al a nis Bottom View Volume 6 Solid State Motor Control 08100007 2014 www eaton com 6 2 247 28 9000 Drives Approximate Dimensions Inches mm Enclosure Size 9 Adjustable Frequency Drives
12. 3 jg po D8 57 D6 2 D1 lt D2 w1 o o ah 3 H3 1 ii 4 5 M o o o E H H N Dia 2 Weight wi W W W W H H2 H H4 H5 01 02 03 D4 D 06 07 D 1 Dia 2 Dia 3 Lbs kg 18 74 5 91 1752 4 57 335 41 54 246 3986 41 34 0 69 14 69 0 51 0 73 642 256 1 06 1 57 5 91 5 24 0 35 0 59 0 51 037 295 476 150 445 116 85 1055 62 5 1012 5 1050 17 5 373 13 185 163 65 27 40 150 33 8x15 13 95 134 Number of Input Units 480V Input 690V Input Catalog Number hp Modules Catalog Number hp Modules SPX800A0 4A2N1 800 2 SPX800A0 5A2N1 800 2 SPX900A0 5A2N1 900 2 SPXH10A0 5A2N1 1000 2 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 71 2 4 5 9000 Drives Approximate Dimensions Inches mm FR13 Open Chassis Converter 900 1000 hp 480V 1 W4 W4 W4 W4 WA e a 419 0096 m o o o o o o ra
13. Operator Elements Latch When Specified ou Inside Filtered 2374 9 Locking Enclosure Door Intake Air Ventilating ss Slots lt 35 75 908 0 gt lt 48 00 1219 2 656 2 Fxhaust Air lt 29 58 Venting Slots 751 2 18 00 x 8 50 457 2 x 215 9 Bottom Access 744 7 9 08 t 1 230 5 3 11 78 9 6 82 lt 3743 950 7 gt 173 3 ke 45 32 1511 CPX9000 Enclosure Dimensions Enclosure Approx Shipping Size o Width Height Depth Weight in Lbs kg 7 30 00 762 0 90 00 2286 0 21 50 546 1 1000 454 8 48 00 1219 2 90 00 2286 0 26 14 664 0 1400 636 9 60 00 1524 0 90 00 2286 0 25 74 653 8 1800 817 10 80 00 2032 0 90 00 2286 0 31 75 806 5 2100 953 11 120 00 3048 0 90 00 2286 0 25 74 653 8 2500 1 135 60 00 1524 0 93 50 2374 9 37 50 952 5 2500 1 135 Notes Enclosure sizes accommodate drive and options including bypass and disconnect For other power options consult your Eaton representative Consult factory Limited power options available Enclosure size 11 consists of two of the enclosure size 9 AII Type 3R drives use the Size F enclosure V6 T2 250 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives LCX
14. LCX9000 Drives Approximate Dimensions in Inches mm Chassis Size CH74 ii Y ITU fi Ja 10101 Leje 2019 E HW HO OE o AA MHE S mm Wi i m i mmm mmm e O Wm 6 Ee LO iii CO COS W r FH L Boom wa gt sx R1 lt D1 gt Front Side Weight Voltage Amps H1 H2 H3 D1 W1 W2 W3 W4 R1 Dia R2 Dia Lbs kg 380 500 Vac 1370 2300 42 38 1 57 39 37 14 65 29 06 0 91 7 87 9 69 0 51 0 55 617 280 525 690 820 1500 1076 5 40 0 1000 0 372 0 738 0 23 0 200 0 246 13 0 14 0 Control Unit D1 D2 Ha _ 4 H1 H3 Lo P 4 Bottom zz Y b 9 lt WI Front Side Back H1 H2 H3 D1 D2 12 93 0 33 11 81 2 95 0 33 5 75 328 5 8 5 300 0 75 0 8 5 146 0 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 267 2 10 Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products SPA9000 SPN9000 SP19000 Common DC Bus Drive Products Product Description Eaton offers a comprehensive range of common DC bus drive products The product family covers a number of front end units and inverter units in the entire power range from 1 1 2 to 2000 horsepower at 460V
15. 2 4 00 101 6 3 00 76 2 Minimum Free Air Minimum Air n 6 Space Required 1 A Required Both Sides J H1 H2 9 H Y 0 44 11 2 Mounting Holes gt lt W1 4 Places W gt D1 lt D gt ask o Approximate Approximate Weight Shipping Weight H H1 H2 w W1 D D1 Lbs kg Lbs kg 40 00 38 00 36 35 20 92 19 30 16 76 2 34 185 84 229 104 1016 0 965 2 923 3 531 4 490 2 425 7 59 4 V6 T2 212 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 7 9000 Drives Approximate Dimensions Inches mm Enclosure Size C UL Type 12 0 44 11 2 0 44 11 2 lt W1 3 00 76 2 Mounting 00 101 6 Minimum 3 00 76 2 Mounting 4 00 101 6 Minimum Minimum Air Holes Free Air Space Required J Minimum Air Space Holes Free Air Space Required R ale 4 Places EM GA Required Both Sides 4 Places aaa JRC equired Both Sides I x Wl 6 9 q 6 Aa 2 D e e e 1 e H1 H2 H H2 H4 H3 P W1 gt lt W gt Di lt D gt a ET DA
16. W7 W5 0 gt gt W6 W6 4 lt lt lt WA leo 9 o o E 1 i oe qe ones 03 2 06 07 OJ D5 UE D4 2 lt gt lt gt lt gt lt gt I lt W3 W3 W3 W3 W2 lt W1 lt D1 gt a O lo L H1 o Operator Shown with Optional Disconnect J H3 y 5 s 5 M F Weight wi wa W W W WG W H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 Dia 1 Dia 2 Dia 3 Lbs 23 43 2 46 453 079 595 295 3011 7945 7480 2018 2370 17 44 1902 047 1122 17 60 2008 083 1 89 043 857 595 62 5 115 20 51 75 79 2018 1900 512 5 602 443 483 12 285 447 510 21 48 11 389 V6 T2 66 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Approximate Dimensions Inches mm FR10 Open Chassis lt H3 gt H5 gt Y pa a
17. Converter Power module 2 1 FR11 0590 4 ANV FR11 0460 5 ANV 1 FR11 0650 4 ANV FR11 0502 5 ANV 1 FR11 0730 4 ANV FR11 0590 5 ANV Driver board 1 S00452 00452 Driver adapter board 1 VB00330 VB00330 Shunt board 9 VB00513 VB00512 9 VB00514 VB00546 9 VB00538 VB00547 Covers Top cover 1 FR11345 FR11345 DC section Balancing resistor 3 PP13027 PP13027 DC busbars kit right 3 0000005 0000005 capacitor 18 00335 00335 Inverter Rectifier module 1 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 1 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly right 3 10847 10847 3 01080 01080 Fan fuse 4 PP20202 PP20202 Starting 3 S00530 S00530 Fan driver board AC 3 VB00299 VB00299 Isolation transformer right 3 FR10845 FR10845 Main DC fan DC fan 2 00072 00072 DC power supply 2 801017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 54 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com FR12 Spare Parts Adjustable Frequency Drives SVX9000 Drives Quantity
18. Knockouts 1 ccc Y D1 D3 Y Y Weight Knockouts at Inches mm Voltage hp ly H1 H2 H3 01 02 03 W1 W2 R1Dia R2Dia Lbs kg 0 D 230 20 30 24 8 630 242 614 23 2 590 10 1 257 3 0 77 7 3 184 9 3 237 75090 0 7 18 0 4 9 77 2 35 3 at 1 5 37 480V 40 60 575V 30 40 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 147 2 5 Adjustable Frequency Drives SPX9000 Drives Approximate Dimensions in Inches mm Type 1 1 21 and Type 12 1 54 FR8 E H2 1 WI W2 E y_ E R2 R1 gt SE E I I I I I Cs 7 01 iii 9 O SE TP Y Weight Voltage ly 01 H1 H2 H3 wi W2 R1 Dia R2 Dia Lbs kg 230V 40 60 13 5 344 300 1 764 28 8 732 28 4 721 11 5 291 10 255 0 7 18 0 4 9 127 58 480 75 125 575V 50 75 V6 T2 148 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 5 SPX9000 Drives Approximate Dimensi
19. gt sok non condensing Jump frequencies Three with adjustable width Maximum elevation 1000 meters 3300 ft Parameter security Programmable software lock Enclosure Preset speeds Two preset speeds Standard Protected chassis IP20 Reversing Keypad or terminal Frorective Features Speed setting Keypad terminal or pot Ground fault Standard RUN STOP control Keypad or terminal Overigad protectign Standard Stop modes Decel coast or DC injection Overcurrent Standard Overvoltage Standard Undervoltage Standard Reliability Overtemperature Standard Description Specification Overload limit Standard Pretested components Standard Surface mount technology Standard PCBs Computerized testing Standard Final test with full load Standard Eaton s Engineering National network of AF drive specialists Systems and Service Note The motor can be electronically stopped in the shortest possible time without using an optical external braking resistor V6 T2 4 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 9000 Drives Watts Loss Watts Loss Catalog Number Horsepower Volts 9kHz 25 0 1 1 4 115 20 NFXF50A0 1 1 2 20 NFXF25A0 2 1 4 230 Vac 20 NFXF50A0 2 1 2 20 NFX001A0 2 1 38W NFX002A0 2 2 75W Wiring Diagrams Control Terminal Wiring Factory Settings RA
20. Y v v 10 C Side View Front View gt M L For Cable Entry Y lp hp 480V 300 0 56 14 2 Dia 2 P 147 Mounting Hole AN 4 Places G 4 Bottom View For reference only dimensions are subject to change See Page V6 T2 80 notes 3 and 5 for enclosure and option selection Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 30 0 762 90 0 2286 26 0 660 26 5 673 1 8 46 17 3 438 5 5 140 84 4 2143 4 0 102 Max Approx Cable Entry Door Clearance Shipping Weight L M N P R S T U V w RR ss TT UU Lbs kg 23 5 33 45 19 3 26 2 24 8 93 9 1500 681 597 84 114 490 667 629 2386 V6 T2 96 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Size 8 T gt For Top Cable Entry S 2 Places ma B H j RR Y O b Y C E U gt lt V lt A gt Side View Front View 0 56 14 2 Dia Mounting Hole LJ 71 4 480V 300 350 400 a M L gt Bottom 4 m Cable Entry hp E L N P
21. ZK Drive Circuit Breaker Door Handle key lock optional 60 00 1524 0 Front View 8 50 x 12 00 215 9 x 304 8 32 72 831 1 gt Bottom Access 25 00 635 0 11 93 303 0 8 20 208 3 lt 46 30 1176 0 54 90 1394 5 Bottom View CA08100007E May 2014 www eaton com Approximate Shipping Weight Lbs kg 1800 817 Adjustable Freguency Drives 2 6 9000 Drives 9000 Enclosed Clean Power Drives Contents Description Page CPX9000 Enclosed Clean Power Drives Application Description V6 T2 222 Features and Benefits V6 T2 227 Catalog Number Selection V6 T2 228 Product Selection 6 2 229 6 2 237 Technical Data and Specifications V6 T2 243 Wiring Diagrams V6 T2 245 Dimensions V6 T2 246 Product Description Eaton s CPX9000 clean power drives use advanced 18 pulse clean power technology that significantly reduces line harmonics at the drive input terminals resulting in one of the purest sin
22. Extended Cards 2 RO therm B u Encoder low volt 5V 15V 24V C 4 A4 u high volt 15V 24V C OPTA5 5 u u nm Double encoder SPX only C OPTA7 7 u u 6 DI 1 DO 2 Al 1 AO A OPTA8 A8 u 6 DI 1 DO 2 Al TAO 1 10 ref A OPTA1 2 ext 24 Vdc EXT 24 3 DI encoder 10 24V out 15V 24V C OPTAE AE 2 DO pulse direction SPX only 6 DI 1 DO 2 Al TAO 1 10 ref A OPTAFA1 2 ext 24 Vdc EXT 24 6 DI 1 ext 24 Vdc EXT 24 B C D E OPTB1 B1 1 RO 1 RO NO 1 therm D E 2 B2 1 Al mA isolated 2 AO mA isolated C D E 0PTB4 4 u u u u u u 1 ext 24 Vdc EXT 24 3 RO C D E 5 B5 1 ext 24 Vdc EXT 24 3 Pt100 D 8 B8 1 RO NO 5 DI 42 240 input D E 9 9 SPI absolute encoder C 0 BB Communication Cards Modbus D E 0 2 C2 u u u u u u u Johnson Controls N2 D E OPTC2 CA Modbus TCP D E 0 Cl BACnet D E C4 EtherNet IP D E PROFIBUS DP D E LonWorks D E OPTC4 C4 m PROFIBUS 09 DE OPTC5 C5 u u u u u u u
23. SVX9000 Drives 230V Drives continued SVX9000 Enclosed Pump Panel Style Single Phase Drives NEMA Type 12 1P54 NEMA Type 3R Enclosure Frame Base Catalog Frame Base Catalog Size hp Size Number Size Number Low Overload Drive and Enclosure A 3 4 4 SVXF072JBP 4 SVXF073JBP 1 SVX0012JBP SVX0013JBP 2 5 SVX0022JBP 5 SVX0023JBP 3 SVX0032JBP SVX0033JBP 5 SVX0052JBP SVX0053JBP 1 1 2 6 SVX0072JBP 6 SVX0073JBP 10 SVX0102JBP SVX0103JBP B 15 7 SVX0152JBP 7 SVX0153JBP 20 SVX0202JAP SVX0203JAP C 25 8 SVX0252JAP 8 SVX0253JAP 30 SVX0302JAP SVX0303JAP 40 SVX0402JAP SVX0403JAP Notes Enclosure dimensions starting on Page V6 T2 112 Includes drive local remote keypad and enclosure Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 103 2 4 Adjustable Freguency Drives 5 9000 Drives 480V Drives 9000 Enclosed Enclosed Pump Panel Style Three Phase Drives Type 12 IP54 NEMA Type 3R Enclosure Frame Base Catalog Frame Base Catalog Size hp Size Number Size Number High Overload Drive and Enclosure A 1 4 SVX00124EP 4 SVX00134EP 1 1 2 SVXF1524EP SVXF1534EP 2 SVX00224EP SVX00234EP 3 SVX00324EP SVX00334EP 5 SVX00524EP SVX00534EP 7 1 2 5 SVX00724EP 5 SVX00734EP 10 SVX01024EP SVX01034EP 15 SVX01524EP SVX01534EP 20 6 SVX02024EP 6 SVX02034EP 25 SVX02524EP SVX02534EP B 30 7 SVX03024EP 7 SVX
24. Operating ambient temperature 0 to 40 Storage temperature 40 to 60 Humidity maximum non condensing 95 Altitude maximum without derate 3300 ft 1000m Line voltage variation 10 15 Line frequency variation 45 66 Hz Efficiency gt 96 Power factor displacement 0 96 V6 T2 110 Volume 6 Solid State Motor Control Two analog input configurable w jumpers Voltage 0 10V gt 200 kohms Current 0 4 20 mA 250 ohms Form C relays 250 Vac 30 2 amp resistive 0 20 mA max 500 ohms 10 bits 2 Two digital output programmable One analog output programmable configurable w jumper One digital output programmable Open collector 48 Vdc 50 mA I O Specifications for Control Communication Options Description Specification 0 10V R 2200 kohms 0 4 20 mA 250 ohms 24V 0 10V 1 218V gt 5 kohms 24V 42096 max 50 mA 10V 3 max 10 mA Analog voltage input Analog current input Digital input Auxiliary voltage Reference voltage Analog current output 0 4 20 mA R 500 kohms resolution 10 bit accuracy lt 2 Analog voltage output 0 2 10V R 21 kohms resolution 10 bit accuracy lt 2 Relay output 300 Vdc 250 Vac 8A 24 Vdc 0 4A 300 2 kVA 250 Vac Maximum continuous load 2A rms 4 7 kohms Maximum switching voltage Maximum switching lo
25. Opening W7 WS W6 FR7 FR8 Dia B o r Y PE H13 gt lt H8 gt W1 W2 W3 wa H1 H2 H3 H4 H5 H6 H7 D1 D2 Dia FR7 9 3 237 6 8 175 10 6 270 10 0 253 24 9 652 24 8 632 24 8 630 741189 7 4 189 0 9 23 0 8 20 10 1 257 4 6 117 0 3 6 FR8 11 2 285 14 0 355 13 0 330 32 8 832 29 3 745 10 2 258 10 4 265 1 7 43 2 2 57 13 5 344 4 3 110 0 4 9 Flange Opening 7 FR8 w5 W6 w H8 H9 H10 H11 H12 H13 Dia FR7 9 2 233 6 9 175 10 0 253 244 619 741189 7 4 189 1 4 35 1 3 32 1 0 25 0 3 6 FR8 11 9 301 13 0 330 31 9 810 10 2 258 10 4 265 1 3 33 0 4 9 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 63 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm NEMA 1 IP21 and NEMA Type 12 IP54 FR9 I H4 gt lt H3 gt W4 TI 11 1 ied parang ara w2 1 15 ws dnd NIA 94 e H2 H1 gt Dia R Voltage hp IH wi w2 wa H1 H2 H3 H4O D1 D2 D3 Dia 230V 75 100 18 9 15 7 0 4 21 45 3 441 0 6 74 142 134 112 0 8 321 9 146 480V 150 200
26. 1 IP21 and NEMA Type 12 IP54 FR9 6 H4 H3 gt W4 TI 11 1 ied parang ara w2 1 15 ws dnd NIA 94 e H2 H1 gt Dia R Voltage hp IH wi w2 wa H1 H2 H3 H4O D1 D2 D3 Dia 230V 75 100 18 9 15 7 0 4 21 45 3 441 0 6 74 142 134 112 0 8 321 9 146 480V 150 200 480 400 9 54 1150 1120 16 188 361 5 340 285 21 575V 100 175 Note Brake resistor terminal box H6 included when brake chopper ordered V6 T2 150 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 5 SPX9000 Drives Approximate Dimensions in Inches mm Type 1 1 21 and Type 12 1 54 FR9 with Flange Kit gt lt H7 i i W5 lo W1 9 ha 5 5 5 Dia A m 6 d D1 m D2 3 03 Y e H4 gt lt H2 gt gt H5 gt 5 H3 b H3 H3 idi H5 i W4 Flange Opening o FR w2 W4 o SY Y gt lt H1 gt 20 5 Dia W1 W2 W3 W4 5 H1 H2
27. Chassis UL Type 1 UL Type 12 UL Type 3R Frame Disconnect Only With Power Options Disconnect Only With Power Options Disconnect Only With Power Options FR4 N A N A B FR5 N A N A B C B C FR6 N A N A B C B C FR7 N A 4 C 7 C D FR8 7 7 7 7 FRO 8 8 8 8 F F Enclosure Dimension Drawings Enclosure Size UL Type 1 and UL Type 12 UL Type 3R B See Page V6 T2 212 See Page V6 T2 214 C See Page V6 T2 213 See Page V6 T2 215 D N A See Page V6 T2 216 F N A See Page V6 T2 217 1 Page 6 2 218 8 Page 6 2 219 9 See Page V6 T2 220 Notes FR5 FR7 drives not available in UL Type 1 Enclosures 7 and 8 are NEMA 12 filtered Not available for UL Type V6 T2 198 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives CFX9000 Drives 2 7 230V Drives CFX9000 Drive UL Type 1 UL Type 12 UL Type 3R and NEMA 12 Filtered EZ NEC Chassis ULType1 UL Type 12 and NEMA 12 Filtered UL Type 3R hp Current A Frame Base Catalog Number Base Catalog Number Base Catalog Number Low Overload Drive 7 1 2 22 FR5 O CFX00722BA CFX00732BA 10 28 FR5 O CFX01022BA CFX01032BA 15 42 FR6 CFX01522BA CFX01532BA 20 54 FR6 CFX02022BA CFX02032BA 25 68 FR7 CFX02522AA CFX02532AA 30 80 FR7 CFX03022AA CFX03032AA 40 104 FR7 CFX04022AA CFX04032AA 50 130 FR8 CFX05012AA CFX05062AA CFX05032AA 60 154 FR8 CFX06012AA CFX06062AA
28. Low Overload AC Current High Overload AC Current Imax Frame li cont A limin A min A lo A Catalog Number FR4 43 47 33 5 6 2 SPI003A1 4A3N1 9 9 9 7 6 11 4 14 SPI007A1 4A3N1 12 13 2 9 13 5 18 SPI009A1 4A3N1 FR6 16 17 6 12 18 24 SPI012A1 4A3N1 23 253 16 24 32 SPI016A1 4A3N1 31 34 23 35 46 SPI023A1 4A3N1 38 42 31 47 62 SPI031A1 4A3N1 46 51 38 57 76 SPI038A1 4A3N1 FRZ 72 79 61 92 122 SPI061A1 4A3N1 87 96 72 108 144 SPI072A1 4A3N1 105 116 87 131 174 SPI087A1 4A3N1 FR8 140 154 105 158 210 SPI105A0 4A3N1 9 170 187 140 210 280 SPI140A0 4A3N1 205 226 170 255 336 SPI170A0 4A3N1 261 287 205 308 349 SPI205A0 4A3N1 300 330 245 379 444 SPI245A0 4A3N1 FI10 385 424 300 450 540 SPI300A0 4A3N1 460 506 385 578 693 SPI385A0 4A3N1 520 572 460 690 828 SPI460A0 4A3N1 12 590 649 520 780 936 SPI520A0 4A3N1 650 715 590 885 1062 SPI590A0 4A3N1 730 803 650 975 1170 SPI650A0 4A3N1 820 902 730 1095 1314 SPI730A0 4A3N1 920 1012 820 1230 1476 SPI820A0 4A3N1 1030 1133 920 1380 1656 SPI920A0 4A3N1 13 1150 1265 1030 1545 1854 SPIH10A0 4A3N1 1300 1430 1150 1720 2070 SPIH11A0 4A3N1 1450 1595 1300 1950 2340 SPIH13A0 4A3N1 F114 1770 1947 1600 2400 2880 SPIH16A0 4A3N1 2150 2365 1940 2910 3492 SPIH19A0 4A3N1 Note For filter and line reactor information see Page V6 T2 274 V6 T2 272 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Common DC Drive Products 5 9000 Active Front End 57
29. h q CE eet 0909 lt D1 Side Weight Voltage Amps H1 H2 H3 D1 W1 R1 Dia R2 Dia Lbs kg 380 500 460 730 42 38 1 57 39 37 14 65 7 87 0 55 0 51 198 90 1076 5 40 0 1000 0 372 0 200 0 14 0 13 0 525 690 261 502 V6 T2 266 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 9
30. Type 1 1 21 FR11 Freestanding Drive W5 we we we wewW7 WIW6 We we W4 lt lt 600799000 gt I Dia 3 Dia 1 Dia 2 D3 E D5 a 5 W3 W3 W3 W3 We lt W1 01 a 5 H1 9 H2 Operator Shown with POR ana Y Voltage wi W W W W6 ws H1 H2 H3 01 02 03 04 05 Dia 1 Dia 2 Dia 3 Weight Lbs kg 480V 400 550 31 26 2 40 650 0 79 343 295 252 118 17945 7480 2018 23 70 11 22 1909 047 17 60 0 83 1 89 0 35x0 43 526 690V 400 500 794 61 165 20 87 75 6 30 2018 1900 512 5 602 285 485 12 447 21 48 9x11 239 V6 T2 154 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm FR11 Open Chassis W3 W3 2 W2 do Y VIE
31. 300 400 hp and 250 350 hp lj 480 250 400 hp and 200 300 hp ly 575V 150 38 1 gt s ZZ e de H ee e 77 i NS 90 R B III OK CJ E AE 90 00 1 pn LN Door Handle oles KN gt up awe wii V6 T2 248 Volume 6 Solid State Motor Control Bottom View CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 8 9000 Drives Approximate Dimensions in Inches mm Enclosure Size 10 500 600 hp and 400 500 480V 500 600 hp and 400 500 hp lj 575V lt 15 63 gt 397 0 N 7 9 03 D D D D 21 00 x 10 00 4 533 4 x 254 0 Access t j x View A 4 00 101 6 Minimum Free Air Space Required fended 4 O em isconnect E Chrouit Breaker When Specified
32. 5 9000 Drives FR8 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 CP01180 01180 01180 Control module SPX control module 1 50000000000 50000000000 50000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power board 1 VB00722 0140 2 ANV VB00636 0140 4 ANV VB00422 0062 5 ANV 1 VB00722 0170 2 ANV VB00636 0168 4 ANV VB00422 0080 5 ANV 1 VB00722 0205 2 ANV VB00636 0205 4 ANV VB00422 0100 5 ANV IGBT 2 PP01175 PP01175 PP01127 DC section Bus capacitor 4 00335 00335 01041 Inverter Diode 3 CP01268 CP01268 CP01373 Rectifier board 1 VB00227 VB00227 VB00427 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan AC 1 01123 01123 01123 Fan fuse 2 20202 20202 20202 Starting 1 500734 500734 500734 Fan driver board 1 VB00599 VB00799 VB00799 Isolation transformer fan 1 0000113 0000113 0000113 Main DC fan DC fan 1 00071 00071 00071 DC power supply 1 S01016 S01016 S01016 Other Front cover N12 1 FR08079 FR08079 FR08079 Conduit plate N12 1 FR08082 FR08082 FR08082 Front cover N 1 FR08106 FR08106 FR08106 Notes Only for NEMA Type 12 54 Type drives Factory recommended spare par S G Select one part number based on the a
33. B H D W 5 Door Clearance Y lt A gt Top View Front View NEMA Type 1 IP21 0 56 14 2 Dia Mounting Holes For Cable 4 Places Entry t lo t v Ix SS Y a 01 gt le D A RH lt M Bottom View IL hp 208 230V 75 100 480V 200 250 Front View NEMA Type 12 1 54 For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K Enclosure Size 5 2P 60 0 1524 90 0 2286 21 3 541 36 0 914 2 0 51 8 0 203 108 273 84 4 2143 4 0 102 Max Approx Cable Entry Door Clearance Shipping Weight L M N P R S T U V w RR ss TT UU Lbs kg 17 0 18 0 1 5 1 0 0 9 36 3 20 0 18 4 1 3 94 0 15 5 1585 720 432 457 38 25 23 921 508 466 32 2387 394 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 95 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm Size 6 s MT NE KEEL _ j e Keypad with Circuit Breaker When Specified Flanged Disconnect Supplied Operator Elements When Specified kak Mounted onThese Panels RR Key Locking Handle Slots TIE QuarterTurn Latch VM 2 Places
34. lt 8A 24Vdc i lt 0 4A 300 ra ita 2 kVA 250 Vac W Continuously lt 2 Arms 5 Circuit Breaker RO2 3 26 Optional Fuse To Drive Input To Drive Output U T1 V T2 W T3 Optional Output Contactor 1 V T2 U T1 eS W T3 08100007 2014 www eaton com V6 T2 111 Volume 6 Solid State Motor Control 2 4 Adjustable Freguency Drives 5 9000 Drives Dimensions Approximate Dimensions Inches mm SVX9000 Pump Application Drives Enclosure Box A NEMA 12 IP54 4 00 101 6 3 00 76 2 Minimum Free Air Minimum Air 1 Space Required 0 Space A 1 A Required r Both Sides o Qe P H1 H2 H b Y 0 44 11 2 Y 6 Mounting Holes o IY lt W1 4 Places lt w gt l D1 lt y D I E Voltage hp hp Weight Shipping Weight AC ly 1 H H1 H2 w wi D D1 Lbs kg Lbs kg Three Phase 208V 3 4 10 1 15 29 00 27 00 25 35 16 92 15 30 16 26 2 34 120 54 160 73 2307 37410 115 736 6 685 8 643 9 429 8 388 6 413 0 59 4 480V 1 25 1 30 Single Phase 230 3 4 10 29 00 27 00 25 35 16 92 15 30 16 26 2 34 120 54 160 73 1807 3 4 20 736
35. 2014 www eaton com Adjustable Freguency Drives 7 6 Series Drives Series IntelliPass 3R Two Contactor Bypass Standard HX 208 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 6 HMX4D651NA 2 75 HMX7D551NA 3 10 6 HMX01151NA 5 5 16 7 HMX01751NA 75 24 2 HMX02551NA 10 30 8 HMX03151NA 6 15 46 2 HMX04751NA 20 59 4 HMX06051NA 7 25 74 9 HMX07551NA 30 88 HMX08851NA 230 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 2 HMX4D252NA 2 6 8 HMX6D852NA 3 9 6 HMX9D652NA 5 5 15 2 HMX01652NA 75 22 HMX02252NA 10 28 HMX02852NA 6 15 42 HMX04252NA 20 54 HMX05452NA 7 25 68 HMX06852NA 30 80 HMX08052NA 480 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 2 1 HMX2D154NA 2 3 4 HMX3D454NA 3 5 6 HMX5D654NA 5 7 6 HMX7D654NA 75 11 01154 5 10 14 01454 15 21 HMX02154NA 20 27 HMX02754NA 6 25 34 HMX03454NA 30 40 HMX04054NA 40 52 HMX05254NA 7 50 65 HMX06554NA 60 77 07754 75 9 HMX09654NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for NEMA specifics Enclosure size and weight differ from NEMA 1 and 12 products Volume 6 Solid State Motor Control CA08100007E
36. 2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19 200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Communications The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a 10 Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system According to 150 11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay of nominal 5 nS m 120 ohm line termination resistors required for installation V6 T2 238 DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connec
37. 2014 www eaton com Adjustable Freguency Drives 7 6 Series Drives Wiring Diagram Control Input Output PID Application M RJ 45 Modbus TCP Transmission Control Protocol Ethernet Based DB R 771 Optional Optional Chopper R pei LL 5 DC Link ELT B Circuit Se Three Phase SE N 122 V T2 Motor I 4 Single Phase not available Output 1 43 W N 7 Slot A Terminal Factory Default Signal Resistor 1 10V Reference Output Analog Input Voltage Range 0 10 Vdc 2 Al 1 can be programmed to current 4 20 mA Vin Analog Output Common Ground Analog Input Current Range 4 20 mA 4 Al 2 can be programmed to voltage 0 10 Vdc Setpoint or Feedback Factory 5 AI 2 Analog Input Common Jumper PI Setpoint or Feedback Test 6 24Vout Control Voltage Output 0 1 max I ON WH OFF 5485 7 GND Ground CURRENT VOLTAGE AO1 I CURRENT VOLTAGE 2 E 48 DIN1 START STOP Contact closed start CURRENT M VOLTAGE AM 9 2 External Fault Closed fault p Run Interlock Permissive IP Interlock 10
38. 5 W2 W2 z Y ld Shown without terminal cover e o 0 o e 25 B H1 gt W1 Y 4 o 02 q D1 q Y Y Weight Voltage hp ly wi w2 w3 H1 H2 01 02 Lbs kg 480V 400 550 27 9 709 8 6 225 2 6 67 45 5 1155 33 5 850 19 8 503 18 4 468 833 378 575V 400 500 Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 5 V6 T2 155 2 5 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm FR13 Open Chassis Inverter W4 W4 W4 W4 W4 Dia 1 400 rie lt lt gt 4004 W1 818 wi W W 27 87 531 708 150 677 26 65 4 57 116 85 w W H H2 335 4154 246 1055 62 5 2 w2 2 H3 H5 DI D2 3986 4134 079 2177 051 1012 5 1050 20 553 13 A D3 W5 D4 0 63 1 97 16 50 D5 1 06 27 Dia 3 Dia 2 0 35x0 59 0 18 Dia 07 08 1 5 91 9 64 150 244 8 9x15 4 6 Dia 3 0 51 13 Dia Weight 4 Lbs kg 0 37 683 310 9 5 Notes 9000X FR14 is built of two FR13 modules Pleas
39. signal interface with the drive Contro The circuit board is mounted on the inside of the front enclosure panel and connects to the user s pneumatic control system via 6 ft 1 8m of flexible tubing and a 1 4 in 6 4 mm brass tube union K4 HAND OFF AUTO Switch for Non Bypass Configurations Provides a three position selector switch that allows the user to select either a HAND or AUTO mode of Control operation HAND mode is defaulted to keypad operation and AUTO mode is defaulted to control from an external terminal source These modes of operation be configured via drive programming to allow for alternate combinations of start and speed sources Start and speed sources include keypad 1 0 and fieldbus K5 MANUAL AUTO Speed Reference Switch Provides door mounted selector switch for MANUAL AUTO speed reference Contro K6 START STOP Pushbuttons Provide door mounted START and STOP pushbuttons for either bypass or non bypass configurations Contro KF Bypass Test Switch for RB and RA Allows the user to energize the AF drive for testing while operating the motor on the bypass controller The Test Switch is Addl bypass mounted on the inside of the enclosure door KO Standard Elapsed Time Meter Provides a door mounted elapsed run time meter Control Power On Run and Fault Lights Provide a white power on light that indicates power to the enclosed cabinets green run light a red faul
40. 28 Vdc Factory Default Fault Indication Main Circuit Power Terminals Control Circuit Terminals 7 Shielded Leads Note Do not plug a modem or telephone line to the RS 485 communication port permanent damage may result Terminals 1 and 2 are the power sources for the optional copy keypad and should not be used while using RS 485 communication Use power terminals R L1 5 12 for single phase connection to models NFXF25A0 1 NFXF50A0 1 NFXF25A0 2 NFXF50A0 2 or NFX001A0 2 Use power terminals R L1 S L2 and T L3 for three phase connection to models NFXF25A0 2 NFXF50A0 2 NFX001A0 2 or NFX002A0 2 Single phase power must not be used for model NFX002A0 2 V6 T2 6 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 1 9000 Drives Dimensions Approximate Dimensions in Inches mm 1 4 to 2 hp Drive 2 68 68 0 0 20 5 0 2 20 56 0 gt RLI 512 713 A A 199997 QD CO NFX9000 472 520 0 5 120 0 132 0 230V 1 PHASE ZN warning ZYC Z J5 HA RC 4W DT 02 09 04 GND RS 485 J eX Um WT2WT J
41. slave D E OPTC6 C6 u u u u u u u DeviceNet D E 7 7 m m Modbus 09 type DE OPTC8 C8 u u u u u u u Adapter SPX only D E OPTD1 D1 Adapter SPX only D E OPTD2 D2 RS 232 with 09 connection D OPTD3 D3 m m m Notes Al Analog Input AO Analog Output DI Digital Input DO Digital Output RO Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card V6 T2 128 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Modbus RTU Network Communications The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Communications The LonWorks Network Card OPTCA is used for connecting the 9000X Drive on a Lon
42. Output frequency 0 320 Hz standard 7200 Hz special software Frequency resolution Application dependent Control Characteristics Control method Frequency control V f Open loop Sensorless vector control Closed loop Frequency control Closed loop Vector control Switching frequency Adjustable with parameter 2 6 9 480V Up to and including 61 Amp size 1 16 kHz factory default 10 kHz From 72 Amp size 1 12 kHz factory default 3 6 kHz 575V 1 6kHz factory default 1 5kHz Frequency reference Analog input resolution 0 1 10 bits accuracy 1 Panel reference resolution 0 01 Hz Field weakening point 30 320 Hz Acceleration time 0 1 3000 seconds Deceleration time 0 1 3000 seconds Braking torque DC brake 30 x T without brake option V6 T2 258 Volume 6 Solid State Motor Control for applicable UPS weights Storage and shipping Max 15G 11 ms in package Enclosure class 00 open frame standard in entire kW hp range EMC Immunity Fulfils all EMC immunity requirements Emissions EMC level N EMC level T for IT networks Safety Approvals EN 50178 EN 60204 1 CE UL CUL FI GOST R IEC 61800 5 See unit nameplate for more detailed approvals Control Connections 5 alog input voltage 0 to 10V 200 kohm 10V to 10V joystick control Resolution 0 1 accuracy
43. Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan 50 mm fan 1 PP09041 PP09041 PP09041 80 mm fan 1 01068 01068 01068 Control module SVX control module 1 CSBS0000000000 CSBS0000000000 CSBS0000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power module 1 FR09 0261 2 ANV FR09 0261 4 ANV FR09 0125 5 ANV 1 FR09 0300 2 ANV FR09 0300 4 ANV FR09 0144 5 ANV 1 09 0170 5 board 1 800583 800583 00583 Shunt board 6 VB00535 VB00537 6 VB00536 VB00542 6 VB00543 DC section Balancing resistor 3 00052 00052 00052 Bus capacitor 8 00335 00335 01041 DC busbars DC 1 809043 809043 809043 DC busbars DC 1 809044 FR09044 FR09044 DC busbars connection 1 FR09045 FR09045 FR09045 DC busbars insulator 1 FR09046 FR09046 FR09046 DC busbars con insulator 1 FR09047 FR09047 FR09047 Inverter Rectifier module 1 FR09826 FR09822 FR09823 Diode 3 01268 CP01268 CP01268 Rectifier board 1 VB00459 VB00460 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan AC 1 01080 01080 01080 Fan fuse 2 PP20202 PP20202 PP20202 Starting 1 00465 00465 00465 Fan driver board 1 VB00899 VB00399 VB00299 Isolation transformer fan 1 PP09056 PP09055 PP09055 Main DC fan DC fan 1 PP00072 PP00072 PP00072 DC power s
44. RS 485 Modbus as standard PID controller as standard Several fieldbus options EMC At Default Settings EMC Category C2 C3 and C4 Level H With an internal RFI filter option Note See unit nameplate for more detailed approvals V6 T2 23 Adjustable Freguency Drives Series Adjustable Freguency Drives Catalog Number Selection Description Base catalog number Phase V6 T2 24 1 Single phase 3 Three phase Option Enclosure Class 0 Full version 0 0 or IP20 Voltage Software Output Current EMC Filter 1 120V 4 480V Designation Series 106 1 6 Filter 2 230 5 575 010 10 N filter Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Product Selection M Max Basic Controller Adjustable Frequency Drives M Max Series Adjustable Frequency AC Drives 2 3 100 Continuous Nominal Input Frame hp O Volts Current ly Current A Size Catalog Number 1 4 100 120 single phase in 12 92 FS2 MMXTIAATD7NO 0 12 24 11 6 MMX11AA2D4N0 0 3 4 28 12 4 MMX11AA2D8N0 0 1 37 1
45. Second Wave Volts v f x Combine the two waves result is 60 Hz supply rich fifth harmonics Resulting Supply Volts v Time f x sin x sinta Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 7 CFX9000 Drives What Causes Harmonics Harmonics are the result of nonlinear loads that convert AC line voltage to DC Examples of equipment that are non linear loads are listed below AC variable frequency drives DC drives Fluorescence lighting computers UPS systems Industrial washing machines punch presses welders etc How Can Harmonics Due to VFDs Be Diminished By applying drives from the Eaton Clean Power Drives Family The HCX9000 CFX9000 and CPX9000 What Are Linear Loads Linear loads are primarily devices that run across the line and do not add harmonics Motors are prime examples The downside to having large motor linear loads is that they draw more energy than a VFD because of their inability to control motor speed In most applications there is a turn down valve used with the motor which will reduce the flow of the material without significantly reducing the load to the motor While this provides some measure of speed control it is extremely inefficient Why Be Concerned About Harmonics Installation and utility costs increase Harmonics cause da
46. 2 is a multi protocol option card 6 2 106 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Modbus RTU Network Communications The Modbus Network Card 2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Communications The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a 10 Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system According to 15011898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay
47. 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power board 1 VB00722 0140 2 ANV VB00636 0140 4 ANV VB00422 0062 5 ANV 1 VB00722 0170 2 ANV VB00636 0168 4 ANV VB00422 0080 5 ANV 1 VB00722 0205 2 ANV VB00636 0205 4 ANV VB00422 0100 5 ANV IGBT 2 PP01175 PP01175 PP01127 DC section Bus capacitor 4 00335 00335 01041 Inverter Diode 3 CP01268 CP01268 CP01373 Rectifier board 1 VB00227 VB00227 VB00427 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan AC 1 01123 01123 01123 Fan fuse 2 20202 20202 20202 Starting 1 500734 500734 500734 Fan driver board 1 VB00599 VB00799 VB00799 Isolation transformer fan 1 0000113 0000113 0000113 Main DC fan DC fan 1 00071 00071 00071 DC power supply 1 S01016 S01016 S01016 Other Front cover N12 1 FR08079 FR08079 FR08079 Conduit plate N12 1 FR08082 FR08082 FR08082 Front cover N 1 FR08106 FR08106 FR08106 Notes Only for NEMA Type 12 54 Type drives Factory recommended spare par S G Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 4 V6 T2 51 2 4 Adjustable Freguency Drives SVX9000 Drives 9 5 Parts
48. Analog input voltage 0 to 10V R 200 kohms differential Resolution 0 1 Accuracy 1 DIP switch selection voltage current Analog input current 014 to 20 mA 250 ohms differential Digital inputs 6 Positive or negative logic 18 to 30 Auxiliary voltage 24V 10 max 250 mA Output reference voltage 10V 3 max load 10 mA Analog output 0 10V 0 4 to 20 mA R max 500 ohms Resolution 10 bit Accuracy 2 DIP switch selection voltage current Relay outputs 3 programmable 2 Form C 1 Form A relay outputs Switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Hard wire jumper Between terminal 6 and 10 factory default DIP switch setting default RS 485 off A01 current A12 current A11 voltage Protections Overcurrent protection Yes Overvoltage protection Yes DC bus regulation anti trip Yes accelerates or decelerates the load Undervoltage protection Yes Earth fault protection Yes in case of earth fault in motor or motor cable only the frequency converter is protected nput phase supervision Yes trips if any of the input phases are missing Air quality Chemical vapors 60721 3 3 unit in operation Class 3C2 otor phase supervision Yes trips if any of the output phases are missing Mechanical particles IEC 60721 3 3 unit in operation Class 352 Overtem
49. CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency Drives Technical Data and Specifications DC1 Series Ratings Specifications PowerXL DC1 Basic Controller IP20 Standard Ratings PowerXL DC1 Series Drives Description Specification Description Specification Protections Input Ratings Overload protection 150 for 60s for every 600 seconds Input voltage Vin 10 Overvoltage protection Yes Input frequency fin 50 60 Hz variation up to 48 62 Hz Undervoltage protection Yes Connection to power Maximum of one time every 30 seconds Ground fault protection Yes Output Ratings Overtemperature Yes Output voltage 0 to V protection Continuous output Continuous rated current In at ambient temperature max Motor overload protection Yes current 22 F 50 C 150 for 60 seconds 175 for 2 seconds D Motor stall protection Yes Output frequency 010 500 Hz Frequency resolution 0 1 Hz Initial output current lu 175 for 25 for every 20 seconds Programmable Parameters orque depends on motor Description Control Characteristics Built in Help card Operation mode U f control slip compensation 14 Standard operation parameters Switching frequency 4 to 32 kHz Reference scaling Voltage reference 10 Vdc 10 mA Programmable start and stop functions Field weakening point to 5
50. PROFIBUS DP D E C3 LonWorks D E OPTC4 C4 m PROFIBUS DP 09 connector D OPTC5 C5 slave D E 6 C6 DeviceNet D E OPTC7 C7 Modbus 09 type D OPTC8 C8 m RS 232 with D9 connection D E OPTD3 D3 m Notes Al Analog Input AO Analog Output DI Digital Input DO Digital Output RO Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card V6 T2 204 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Modbus RTU Network Communications The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19 200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Commu
51. sh t Adjustable Frequency Drives w3 gt Dia 4 d 9 o e le Y 3 D lo y D7 D6 W1 gt L 151 LLL H 1 H YL T 1 r J los wi W W W W H H2 H3 H5 01 02 03 D4 2787 5 91 26 65 457 3 35 41 54 2 46 3986 41 34 0 69 14 69 0 51 0 73 6 4 708 150 677 116 85 1055 62 5 1012 5 1050 17 5 373 13 185 16 03 05 06 07 2 2 56 1 06 1 57 3 65 27 40 5 91 150 09 2 5 24 0 35 0 59 0 18 133 9x15 4 6 3 0 51 13 Dia Weight 4 Lbs kg 0 37 443 95 201 Number of Input Units 480V Input Catalog Number hp Modules SPX900A0 4A2N1 900 3 SPXH10A0 4A2N1 1000 3 V6 T2 72 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4
52. 10 2 1x Al 2 x AO isolated 10 4 3x Form A 10 5 Form A 501 42 240 Vac input 10 9 LonWorks XMX COM C4 A 1 1 x DO 1 x R 10 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 6 V6 T2 179 2 6 Adjustable Freguency Drives Series Drives Extended Options Slot and Description Suffix Number 6 x DI DO Each digital input can be individually programmed as digital output B1 1R0 NC NO 1RO 1 Thermistor B2 1xAl 2x AO isolated B4 3x RO B5 NO 5 DI 42 240 Vac input 9 Expander IO 1 AO 1 DO 1 RO BF Optional Communications in Slot D and E Description Suffix Number LonWorks C4 IntelliDisconnect Options Description Pilot lights Power ON RUN Fault Suffix Number Fused drive isolation cannot used with P3 Output contactor cannot be used with P3 PE Space heater w transformer Type 3R only SA IntelliPass Bypass Options Description Pilot lights Power ON RUN Fault Suffix Numher L4 Fused drive isolation can not be used with P6 P3 Third contactor drive isolation cannot be used with or 15 P6 Manual bypass switch located on front door Space heater w transformer only SA
53. 12 control fan O 1 PP01049 PP01049 01049 Control module 9 SVX control module 1 CSBS0000000000 CSBS0000000000 CSBS0000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 2 2 2 Converter Power board 1 VB00319 0075 2 VB00619 0072 5 VB00419 0041 6 1 00319 0088 2 00619 0087 5 00419 0052 6 1 VB00319 0114 2 VB00619 0105 5 DC section Bus capacitor 2 01041 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main fan DC fan main 1 PP01063 PP01063 PP01063 Other Mounting kit fixing kit 1 FRO7071 FRO7071 FRO7071 Mounting kit fixing kit N12 O 1 FRO7072 FRO7072 FRO7072 Control cover plastic N1 1 FR07011 FRO7011 FRO7011 Notes Only for NEMA Type 12 IP54 Type drives Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 50 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives SVX9000 Drives FR8 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 CP01180 CP01180 01180 Control module SVX control module 1 CSBS0000000000 CSBS0000000000 CSBS0000000000 Standard slot A 1 0 card 1 9 9
54. Auxiliary contacts K9 Isolation switch IS Standard Onboard Communications Description Suffix Number RS 485 Communications BACnet MS TP Master slave token protocol Universal BACnet RS 485 BACnet Modbus RTU RS 485 ASCII or RTU remote terminal unit 32 nodes Modbus Johnson Controls Metasys N2 network N2 Onboard Ethernet Based Communications port left side of keypad BACnet IP Ethernet industrial protocol BACnet Modbus TCP Transmission control protocol Ethernet based Modbus V6 T2 180 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives Technical Data and Specifications Primary Design Features Series Drives 2 6 Description IntelliPass IntelliDisconnect Description IntelliPass IntelliDisconnect Standard Standard Isolation switch Optional N A 2 contactor bypass Standard N A Top entry power Standard Standard Electrical interlock Standard N A Bottom entry power Standard Standard Third contactor isolation Optional N A Output contactor Standard Optional H Max Series Drives Description Specification Description Specification Input Ratings Standards Input voltage Vin 208 230 480 Vac 10 10 EMC mmunity Fulfills all EMC immunity requirements Input frequency fin 50 60 Hz variation up to 47 66 Hz Emissions EN 61800 3 LEVEL H EMC
55. Digital outputs Open collector output 50 mA 48V Relay outputs 2 programmable change over relay outputs Switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Min switching load 5V 10 mA V6 T2 276 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 7 0 SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products 5 9000 5 9000 5 19000 continued Description Specification Protections Overvoltage protection 480V 911 575 1200 Vdc Undervoltage protection 480V 333 575V 460 fault protection In case of ground fault in motor or motor cable only the inverter is protected Motor phase supervision Trips if any of the output phases is missing Overcurrent protection Yes Unit overtemperature protection Yes Motor overload protection Yes Motor stall protection Yes Motor underload protection Yes Short circuit protection of 24V and 10 reference voltages Yes Input Fuses SHT fuses can be assembled into same size DIN fuse base SPA9000 SPN9000 SPI9000 Module Component Frame Bussman Fuse Type aR Size V In A 0ty Inverter Units SPI003A1 4 FR4 170M1560 0 690 20 2 SPI007A1 4 FRA 170M1562 0 690 63 2 SPI009A1 4 FRA 170M1562 0 690 63 2 SPI012A1 4 FR6 170M1565 0 690 63 2 SPI016A1 4 FR6 170
56. ti Knockouts D2 Weight Knockouts at Inches mm Voltage hp In H1 H2 H3 D1 D2 D3 W1 W2 R1Dia R2 Dia Lbs kg 1 0 D FR4 230V 3 4 3 12 9 12 3 11 5 7 5 30 4 9 5 0 3 9 0 5 13 0 3 7 11 0 5 3 1 1 28 480V 1 5 327 313 292 190 77 126 128 100 FR5 230V 5 7 1 2 16 5 16 0 15 3 8 4 3 9 5 8 5 6 3 9 0 5 13 0 3 7 17 9 8 29 1 5 37 480V 7 1 2 15 419 406 389 214 100 148 143 100 1 1 1 28 FR6 230V 10 15 22 0 21 3 20 4 9 3 4 2 6 5 7 6 5 8 0 6 15 5 0 4 9 40 8 19 3 1 5 37 480V 20 30 558 541 519 237 105 165 195 148 575 2 25 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 59 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions in Inches mm NEMA 1 IP21 and NEMA Type 12 IP54 with Flange Kit FR4 FR5 and FR6 P A H2 lt H1 gt x H4 D1 H5 D f f D2 N Y lt H3 gt H7 gt Dia B 1 Opening Wa FR4 to FR6 WA WS Im Y H8 gt l lt H6 gt 9 FR4 5 FR6 with Kit W1 W2 H1 H2 H3 H4 H5 D1 D2 Dia A 4 5 0 128 4 5 113 13 3 337 12 8 325 12 9 327 1 2 30 0 9 22 7 5 190 3 0 77 0 3 7 5 5 6 143 4 7 120
57. 1 IP21 N No brake chopper circuit 2 NEMA 12 254 Internal brake circuit Voltage Rating Input Options 2 230V 208 240 1 Three phase EMC H 4 480V 380 500 Keypad 2 Three phase N 5 575V 525 690 Alphanumeric 4 Three phase L Notes All 230V drives and 480V drives up to 200 hp lh are only available with input option 1 EMC level 480V drives 250 hp ly or larger available with input option 2 EMC level 575V drives 200 hp or larger are available with input option 2 575V drives up to 150 hp ly are available with input option 4 level L 480V and 690V freestanding drives are available with input option 4 level 1 480V drives up to 30 hp 14 are only available with brake chopper option 480V drives 40 hp ly or larger come standard with brake chopper option N 230V drives up to 15 hp I are only available with brake chopper option B 230V drives 20 hp and larger come standard with brake chopper option N All 575V drives come standard without brake chopper option N N No brake chopper 480V drives 250 350 hp li and 690V drives 200 300 hp are available with enclosure style 0 chassis 480V and 690V FR10 freestanding drives are available with 1 NEMA Type 1 IP21 or 2 NEMA 12 IP54 FR11 freestanding drives are only available with enclosure style 1 NEMA Type 1 21 F
58. 25 NFXF50A0 1 Em 1 4 200 240 49 16 NFXF25A0 2 4 1 2 6 57 2 5 NFXF50A0 2 1 97 42 NFX001A0 2 e 2 9 0 NFX002A0 2 Notes Horsepower ratings are based on the use of a 240V 480V NEMA B four or six pole squirrel cage induction motor and are for reference only Units are to be selected such that the motor current is less than or equal to the NFX9000 rated continuous output current For 208V 380V or 415V applications select the unit such that the motor current is less than or equal to the NFX9000 rated continuous output current Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 3 2 1 9000 Drives Technical Data and Specifications General Specifications 9000 Drives Description Specification Output Ratings Adjustable Frequency Drives Set Up Adjustments Performance Features Operator Control and External Interface Keypad Description Specification Alphanumeric display Standard 1 x 4 character Horsepower 90V 132V 1 4 1 2 hp 200 240V 1 2 2 hp Frequency range 0 1 400 Hz Overload rating 15096 for 60 seconds Frequency resolution Digital 0 1 Hz RUN STOP and FORWARD REVERSE Last three trips with cause Four RUN STOP and FORWARD REVERSE RUN STOP speed control digital or potentiometer RESET MODE keys and ENTER Digital indications Diagnostics LED status indicators Operator function
59. 4 1 Al mA isolated 2 AO mA isolated B9 1 NO 5 DI 42 240 Vac input 1 ext 24 Vdc EXT 24 Engineered Options Varnished boards Local remote keypad is included as the standard control panel Brake chopper is a factory installed option only see drive options on Page V6 T2 37 External dynamic braking resistors not included Consult factory Includes local remote speed reference switch Some options are voltage and or horsepower specific Consult your Eaton representative for details See Pages V6 T2 84 and V6 T2 85 for descriptions See Pages V6 T2 82 and V6 T2 83 for complete descriptions Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 77 V6 T2 78 2 4 SVX9000 Drives Product Selection When Ordering Select a base catalog number that meets the application requirements nominal horsepower voltage and enclosure rating the enclosed drives continuous output amp rating should be equal to or Adjustable Frequency Drives greater than the motor s full load amp rating The base enclosed package includes a standard drive door mounted local remote keypad and enclosure If dynamic brake chopper or control communication option is desired change the appropriate code in the base catalog number For brake chopper options see Page V6 T2 46 See enclosure dimension
60. 45 66 Hz input frequency Standard Setup adjustment provisions Output AC volts maximum Input voltage base Remote keypad display Standard Output frequency range 0 320 Hz Personal computer Standard Initial output current ly 250 for 2 seconds Operator control provisions Overload 1 minute 150 110 Drive mounted keypad display Standard Enclosure space heater Optiona Remote keypad display Standard Oversize enclosure Standard Conventional control elements Standard Output contactor Optiona Serial communications Optional Bypass motor starter Optiona 115 Vac control circuit Optional Listings UL cUL 508C Speed setting inputs Protection Features Keypad Standard Incoming line fuses Standard 200 rating 0 10 Vdc potentiometer voltage signal Standard AC input circuit disconnect Optional 4 20 mA isolated Configurable Phase rotation insensitive Standard 4 20 mA differential Configurable EMI filter Standard FR6 thru FR9 3 15 psig Optional Input phase loss protection Standard Analog outputs Input overvoltage protection Standard Speed frequency Standard Line surge protection Standard Torque load current Programmable Output short circuit protection Standard Motor voltage Programmable Output ground fault protection Standard Kilowatts Programmable Output phase protection Standard 0 10 Vdc signals Configurable w jumpers Overtemperature protection Standard 4 20 mA DC signals Standard DC overvoltage protection Standard Isolated signals Stand
61. A A i L2A LUW zm Input Reactor A A 100 hp CFX9000 480V Drive with Integrated Passive Filter Passive Filter Current harmonics 1 10096 1 0 2490 lg 0 50 15 3 7696 lj 1 196 1 3 0 55 1 65 117 0 80 los 0 80 Power 100 hp 8 6 Amps Advantages Disadvantages e Low cost for smaller horsepower applications e More effective harmonic attenuation than 12 pulse drives e Provides increased input protection for AFD from line transients CA08100007E May 2014 www eaton com Capacitors age over time unlike magnetics Not as effective as 18 pulse drives Challenging to retrofit with bypass applications 3 12 Pulse Converters A 12 pulse converter incorporates two separate AFD input semiconductor bridges which are fed from 30 phase shifted power sources with identical impedance The sources may be two isolation transformers where one is a delta wye design which provides the phase shift and Adjustable Frequency Drives the second a delta delta design which does not phase shift The 12 pulse arrangement allows the harmonics from the first converter to cancel the harmonics of the second Up to approximately 8596 reduction of harmonic current and voltage distortion may be achieved over standard 2 7 9000 Drives six pulse converter This permits a facility to use a larger percentage of AFD loa
62. C1 gi 02 Ibs kg FS2 4 21 107 0 2 95 75 0 9 09 231 0 8 46 215 0 0 31 8 0 7 32 186 0 0 20 5 0 0 24 6 0 0 47 12 0 3 97 1 8 253 5 16 131 0 3 94 100 0 10 75 273 0 10 04 255 0 0 33 8 5 8 03 204 0 0 20 5 0 0 24 6 0 0 47 12 0 7 72 3 5 Sizes FS2 and 253 Degree of Protection 66 4 lt 01 02 I A1 gt Frame Weight Size A Al B B1 B2 C1 1 02 Ibs kg FS2 7 40 188 0 6 93 176 0 10 12 257 0 7 87 200 0 0 79 20 0 9 42 239 3 0 14 3 5 0 16 4 2 0 33 8 5 10 4 4 5 FS3 8 29 211 0 7 78 198 0 12 20 310 0 9 90 252 0 0 98 25 0 10 48 266 3 0 14 3 5 0 16 4 2 0 33 8 5 15 9 7 0 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 21 2 2 Adjustable Freguency Drives PowerXL DC1 DA1 Series Adjustable Frequency Drives Approximate Dimensions in Inches mm DA1 Sizes FS2 and FS3 Degree of Protection IP66 NEMA 4 with Local Controls B1 lt 1 A gt lt Frame Weight Size A B B1 B2 1 02 Ibs kg FS2 7 40 188 0 6 93 176 0 10 12 257 0 7 87 200 0 0 79 20 0 9 42 239 3 0 14 3 5 0 16 4 2 0 33 8 5 10 6 4 8 253 8 29 211 0 7 78 198 0 12 20 310 0 9 90 252 0 0 98 25 0 10 48 266 3 0 14 3 5 0 16 4 2 0 33 8 5 16 1 7 3 V6 T2 22 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequen
63. CFX05024DA CFX05034DA 60 77 FR7 CFX06014DA CFX06024DA CFX06034DA 75 96 FR8 CFX07514DA CFX07564DA CFX07534DA 100 124 FR8 CFX10014DA CFX10064DA CFX10034DA 125 156 FR8 CFX12514DA CFX12564DA CFX12534DA 150 180 FR9 CFX15014DA CFX15064DA CFX15034DA 200 240 FR9 CFX20014DA CFX20064DA CFX20034DA 250 302 FR10 CFX25014DA CFX25064DA 300 361 FR10 CFX30014DA CFX30064DA 350 414 FR10 CFX35014DA CFX35064DA 2 Notes The integrated filter clean power assembly includes a standard drive door mounted local remote keypad and enclosure FR4 FR6 drives not available in UL Type 1 This catalog number is used only with power options Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 7 9000 Drives 9000 Enclosure Chassis 1 UL Type 12 UL Type 3R Frame Disconnect Only With Power Options Disconnect Only With Power Options Disconnect Only With Power Options FR4 N A N A B C B FR5 N A N A B C B C FR6 N A N A B C B C FR7 N A 7 C 7 C D FR8 7 7 7 7 F F FRO 8 8 8 8 F F FR10 9 9 9 9 Enclosure Dimension Drawings Enclosure Size UL Type 1 and UL Type 12 UL Type 38 B See Page V6 T2 212 See Page V6 T2 214 See Page 6 2 213 See Page V6 T2 215 D Page 6 2 216 Page 6 2 217 12 See Page 6 2 218 82 See Page V6 T2 219 9 See Page V6 T2 220
64. Input circuit breaker Input Input line fuses 200 kAIC Input 1 NEMA Type 1 21 P8 SPD 50 per phase Input NEMA Type 12 54 PA SPD 100 per phase Input 6 12 1P54 filtered PE Output contactor Output PF Output filter 100 300 ft Output PG MotoRx 300 600 ft 1000 V uS DV DT filter Output Voltage Rating PH Single overload relay Output 1 208V Dual overload relays Output 2 230V PN Dual overloads for bypass Addl bypass 4 480V RA Manual bypass controller Bypass RB Manual IOB bypass controller Bypass RC Auto transfer HOA bypass controller Bypass Application Torque Braking RD Auto transfer IOB bypass controller Bypass S5 Floor stand 22 in Enclosure A brake chopper S6 Floor stand 12 in Enclosure internal brake chopper 7 10 in expansion Enclosure D lu no brake chopper S8 20inexpansion Enclosure internal brake chopper 9 Space heater Enclosure SA Space heater with CPT Enclosure EL Style Communication Options Enclosed drive C2 Modbus C6 CANopen slave CI Modbus TCP C3 PROFIBUS DP C7 DeviceNet CJ BACnet C4 LonWorks C8 Modbus D9 type CQ EtherNet IP C5 PROFIBUS DP connector C3 RS 232 with 09 D9 connector Johnson Controls connection Control Options B1 6 DI 1 ext 24 Vdc EXT 24 B5 3 NO B2 1 RO 1 RO NO 1 therm B8 1 ext 24 Vdc EXT 24 Vdc 3 Pt100
65. Inverter Inverter Inverter e Low harmonics Pmains Low total mains power Common DC bus Pmains Pmains lt PINu lt X PINU components are used in a Suitable foral e Suitabl multitude of combinations ultable Tor almost every uitable e g Tor sma Drives which are braking can application processing line with transfer the energy directly to un and recoiler em stop the drives in motoring mode coasting Product Comparison Advantages over Conventional Front Ends Eaton Front Ends vs Conventional Non Regenerative Active Conventional Front End Front End Regenerative Front End Input device Choke 1 Filter LCL Choke or auto transformer L Bridge type Diode thyristor bridge IGBT bridge two level type Anti parallel connected thyristor bridge Type of operation Controlled half bridge High frequency modulation Firing angle controlled 1 5 to 3 6 kHz Direction of power Motoring Motoring and regenerating Motoring and regenerating Charging Constant current External required Usually internal DC voltage Nominal approx 1 35 Stable at 10 of nominal Lowered DC voltage for commutation margin alternative Uy approx 110 of 1 35 e g 17 fi approx 83 of 1 35 alternative or alternative Uy autotransformer on regenerative bridge THD Similar to six pulse bridge Very low Similar to six pulse bridge or worse normal 4096 Note Conventional regenerative front end a k a anti parallel thyris
66. Lifting Eyes 2 Places Q 9 NA RR i For Cable Entry h WEE UL D LL LS Y gt View FrontView NEMA Type 1 IP21 0 56 14 2 Dia Mounting Holes For Cable 4 Places Entry 1 n G ss lt D1 m Bottom View 208 230V 75 100 480V 200 250 FrontView NEMA Type 12 1P54 For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 50 0 1270 90 0 2286 21 3 541 36 0 914 2 0 51 8 0 203 10 8 273 84 4 2143 4 0 102 Max Approx Cable Entry Door Clearance Shipping Weight L M N P R S T U V w RR ss TT UU Lbs kg 171 8 0 1 3 1 0 36 3 20 0 18 4 13 94 0 15 5 1375 624 435 203 33 25 921 508 466 32 2387 394 V6 T2 94 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 5 9000 Drives Approximate Dimensions Inches mm Size 5 2P W x A Lifting Eyes ER 2 PR 9 RR Entry N 0 Y T 0 ar L TMT EE
67. nm Encoder high volt 15V 24V SPX only C OPTA5 A5 nm Double encoder SPX only C 7 7 u u 6 DI 1 DO 2 Al 1 AO SPX only A OPTA8 A8 3 DI encoder 10 244 out 15V 24V C OPTAE AE u u u u u u u 2 DO pulse direction SPX only 6 DI 1 ext 24 Vdc EXT 24 B C D E 1 B1 1 RO NC NO 1 RO NO 1 therm B C D E OPTB2 B2 1 Al mA isolated 2 AO mA isolated C D E 0PTB4 4 u u u u u u u 1 ext 424 Vdc EXT 24 3 RO C D E OPTB5 B5 1 ext 24 Vdc EXT 24 3 Pt100 0 8 B8 1 NO 5 DI 42 240 Vac input B C D E 0 9 9 Communication Cards Modbus D E OPTC2 cz u u u u u u u Modbus TCP D E Cl BACnet D E u u u EtherNet IP D E OPTCQ co Johnson Controls N2 D E OPTC2 CA PROFIBUS DP D E LonWorks D E OPTC4 C4 u m m PROFIBUS 09 connector D OPTC5 C5 u u u u u u u CANopen slave DE OPTC6 C6 u u u u u u u DeviceNet D E 7 C7 Modbus 09 type D OPTC8 C8 u u u u Adapter SPX only D E OPTD1 D1 Adapter SPX only D E OPTD2 D2 u u RS 232 with 09 connection D E OPTD3 D3 m Notes Al Analog Input AO Analog Output DI Digital Input DO Digital Output Relay Ou
68. 0 8 39 213 11 81 300 6 30 160 44 20 0087 6 0 9 13 232 11 81 300 6 69 170 57 26 0145 6 0 11 50 292 11 81 300 7 28 185 82 37 CHKO220N6A0 12 05 306 13 86 352 7 28 185 119 54 0325 6 0 13 66 347 13 86 352 7 28 185 132 60 CHK0460N6A0 16 54 423 13 70 348 9 41 239 203 92 0520 6 0 17 60 447 15 51 394 10 71 272 231 105 0590 6 0 20 43 519 15 51 394 10 71 272 276 125 0650 6 0 20 51 521 15 51 394 10 71 272 276 125 0750 6 0 24 72 628 15 51 394 11 10 282 331 150 0820 6 0 24 72 628 15 51 394 11 10 282 331 150 CHK1000N6A0 22 68 576 19 57 497 11 85 301 441 200 CHK1150N6A0 22 83 580 19 57 497 11 85 301 441 200 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 261 Adjustable Freguency Drives LCX9000 Drives 2 9 Approximate Dimensions Inches mm LCX9000 Drives x22 Chassis Size CH3 WI 3 R2 OJ o P oeeleeeleso
69. 0 to 95 RH noncondensing non corrosive no dripping water Air quality Chemical vapors IEC 721 3 3 unit in operation class 3C2 Mechanical particles IEC 721 3 3 unit in operation class 352 Altitude 100 load capacity no derating up to 3280 ft 1000m 1 derating for each 328 ft 100m above 3280 ft 1000m max 9842 ft 3000m Vibration EN 50178 EN 60068 2 6 5 to 50 Hz displacement amplitude 1 mm peak at 3 to 15 8 Hz max acceleration amplitude 1G at 15 8 to 150 Hz Shock EN 50178 EN 60068 2 27 UPS Drop test for applicable UPS weights Storage and shipping max 15G 11 ms in package Enclosure class NEMA 1 IP21 or NEMA 12 IP54 open chassis IP20 V6 T2 144 Volume 6 Solid State Motor Control High Performance Features Speed error 0 0196 depending on the encoder Encoder support Incremental or absolute Encoder voltages 5V RS 422 15V or 24V depending on the option card Torque control Full torque control at all speeds including zero Torque accuracy 296 lt 5 down to zero speed Starting torque 220096 depending on motor and drive sizing Master slave configurations Full capability System analysis Integrated data logger PC communication Fast multiple drive monitoring with PC Inter drive communication High speed bus 12 Mbits s High speed applications Up to 7200 Hz CA08100007E
70. 110 overload for one functions minute Ethernet BACnet and Modbus Eaton Electrical Services amp Systems national network of AF drive specialists Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 169 2 6 Dimensions Approximate Dimensions Inches mm Adjustable Frequency Drives H Max Series Drives H Max Series Frames FS4 FS7 W2 2 lt W3 Hole Center to Center Weight in Voltage hp kw Amps D H1 H2 H3 W1 W2 W3 Lbs kg FS4 230 Vac 075 4 0 55 3 0 3 7 12 5 77 12 89 12 32 11 22 5 04 3 94 3 94 13 2 180 Vac 1575 11 55 3412 197 3 327 5 313 0 285 0 128 0 100 0 100 0 6 FS5 230 Vac 5 10 4 15 18 31 8 73 16 50 15 98 15 04 5 67 4 53 3 94 22 0 480 10 20 75 15 16 31 221 6 419 0 406 0 382 0 144 0 115 0 100 0 10 56 230 15 20 11 15 48 62 9 29 21 93 21 28 20 24 7 68 5 83 5 83 44 1 480 Vac 25 40 185 30 38 61 236 0 557 0 540 5 514 0 195 0 148 0 148 0 20 FS7 230 Vac 25 30 18 5 30 75 105 10 49 25 98 25 39 24 29 9 06 7 48 7 48 82 6 480 Vac 5075 37 55 72 105 266 5 660 0 645 0 617 0 230 0 190 0 190 0 37 5 H Max Series Frames FS8 and FS9 lt WI W2 W3 H2 D EE Hole Center to Center Weight in Voltage hp kW Amps D H1 H2 H3 W2 W3 Lbs
71. 17 0 434 16 5 420 16 5 419 1 4 36 0 7 18 8 4 214 3 9 100 0 3 7 6 7 7 195 6 7 170 22 0 560 21 6 549 22 0 558 1 2 30 0 8 20 9 3 237 4 2 106 0 3 7 Flange Opening FR4 to FR6 W3 W4 w5 H6 H7 H8 H9 Dia B FR4 4 8 123 4 5 113 12 4 315 12 8 325 0 2 5 0 3 7 5 5 3 135 4 7 120 kani 16 2 410 16 5 420 0 2 5 0 3 7 6 7 3 185 6 7 170 6 2 157 21 2 539 21 6 549 0 3 7 0 2 5 0 3 7 V6 T2 60 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Type 1 IP21 and Type 12 IP54 FR7 lt H1 E H2 5 o o ii W2 WI E A Y R2 R1 R2 Knockouts 1 Y D1 Weight Knockouts Inches mm Voltage lu H1 H2 H3 01 02 03 wi w2 R1Dia R2Dia Lbs kg N1 0 D 230V 20 30 24 8 630 242 614 23 2 590 10 1 257 3 0 77 7 3 184 9 3 237 75090 0 7 18 0 4 9 77 2 35 3 at 1 5 37 480V 40 60 575V 30 40 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 61 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm 1 IP2
72. 2014 www eaton com Adjustable Freguency Drives 7 6 Series Drives H Max Series IntelliDisconnect NEMA Type 12 Main Disconnect Standard HMK 208 Vac FS Drive Rated Frame Size Horsepower Amps Catalog Number 4 1 4 6 HMX4D6B1NA 2 75 HMX7D5B1NA 3 11 HMX011B1NA 5 5 17 HMX017B1NA 75 25 HMX025B1NA 10 31 HMX031B1NA 6 15 47 HMX047B1NA 20 60 HMX060B1NA 7 25 75 HMX075B1NA 30 88 HMX088B1NA 230 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 2 402 2 2 6 8 HMX6D8B2NA 3 9 6 HMX9D6B2NA 5 5 15 2 HMX016B2NA 75 22 HMX022B2NA 10 28 HMX028B2NA 6 15 42 HMX042B2NA 20 54 HMX054B2NA 7 25 68 HMX068B2NA 30 80 HMX080B2NA 480 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 2 1 HMX2D1B4NA 2 3 4 HMX3D4B4NA 3 5 6 HMX5D6B4NA 5 7 6 HMX7D6B4NA 75 11 HMX011B4NA 5 10 14 HMX014B4NA 15 21 HMX021B4NA 20 27 HMX027B4NA 6 25 34 HMX034B4NA 30 40 HMX040B4NA 40 52 HMX052B4NA 7 50 65 HMX065B4NA 60 77 077 4 75 96 HMX096B4NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for specifics Enclosure size and weight differ from NEMA 1 and 12 products Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 177 2
73. 22 gauge with 7 pin connector on each end Should be used in conjunction with the 9000XDrive option to avoid damage to the SVX9000 or computer The same cable can be used for downloading specialized applications to the drive SVDRIVECABLE External Dynamic Braking Resistors Used with the dynamic braking chopper circuit to absorb motor regenerative energy for stopping the load and to dissipate the energy flowing back into the drive Resistors are separated into standard duty and heavy duty Standard duty is defined as 20 duty or less with 10096 braking torque while heavy duty is defined as 50 duty or less with 15096 braking torque See Page V6 T2 131 V6 T2 130 Volume 6 Solid State Motor Control 08100007 2014 www eaton com SPX9000 Drive Options Brake Chopper Options The brake chopper circuit option is used for applications that require dynamic braking Dynamic braking resistors are not included with drive purchase Consult the factory for additional dynamic braking resistor selections that are supplied separately A list of common resistors are listed Adjustable Frequency Drives Duty Cycle The duty cycle rating is based on a 60 second period For example the 20 duty cycle resistor can carry 100 current for 12 seconds out of every 60 seconds while the 50 duty cycle resistor can carry 150 current for 30 seconds out of every SPX9000 Drives Torque If the braking torque required is
74. 30 A B 4 Default Signal 22 RO1 Bypass Run 24Vdc GND 1 1 24 Vdc RS 485 RS 485 out in Data Data 23 EA 24Vdc 8A 1 2 7 8 9 10 11 290 gt 10 An Al2 Al2 24vac GND DM COM 25 P RO2 Drive Run 125 Vdc 0 4A 2 out DI1 6 26 sa EM Fault Factory Jumper External Interlock Standards Includes Reliability Digital inputs D1 D6 relay Six digital input Pretested components out analog in out are freely Two analog input Conformal coated programmed One analog output varnished boards The user can assign a single input to multiple functions V6 T2 182 Volume 6 Solid State Motor Control Three relay output RS 485 Ethernet 40 rated 110 overload for one minute Eaton Electrical Services amp Systems national network of AF drive specialists CA08100007E May 2014 www eaton com Series IntelliPass Incoming Power Li 2 p Bypass 9 Circuit 5 a Breaker Optional Fuse or Drive Input Contactor To Drive Input To Drive Output U T1 v T2 W T3 Output Bypass Contactor Contactor Overload Relay Volume 6 Solid State Motor Control Adjustable Frequency Drives H Max Series Drives H Max Series Intell
75. 480 400 9 54 1150 1120 16 188 361 5 340 285 21 575V 100 175 Note Brake resistor terminal box H6 included when brake chopper ordered V6 T2 64 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 5 9000 Drives Approximate Dimensions in Inches mm Type 1 1 21 and Type 12 1 54 FR9 with Flange Kit gt lt H7 W5 lo W1 ha 5 5 5 Dia A Q ___ I d s 5 5 03 Y He H4 gt lt H2 gt lt 4 gt H5 gt lt H3 lt H3 gt lt H3 gt H5 E i W4 Flange Opening o FR w2 W4 o SY Y lt H1 gt 20 5 Dia W1 W2 W3 W4 5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 Dia 20 9 530 20 0 510 19 1 485 7 9 200 0 2 55 51 7 1312 45 3 1150 16 5 420 33000 1 4 35 0 4 9 0 1 2 24 9 362 13 4 340 4 3 109 0 8 21 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 65 2 4 Adjusta ble Freguency Drives 5 9000 Drives Approximate Dimensions in Inches mm 1 IP21 and Type 12 IP54 FR10 Freestanding
76. 730 730 45 61 850 0730 6 0 20604 2 8204 750A N A N A N A CHK0820N6A0 2300A 920 to 1030A 1000 30 41 950 CHK1030N6A0 1150A 1150 26 36 1000 1150 6 0 Dimensions see Page V6 T2 261 Notes nductances for different supply voltages A 400 480 Vac 500 690 Vac Drives require three chokes of the designated catalog number with six pulse supply Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 9 V6 T2 257 Adjustable Frequency Drives LCX9000 Drives 2 9 Technical Data and Specifications LCX9000 Products Description Specification General Specifications Description Specification Ambient Conditions Line voltage 400 to 500 525 to 690 10 to 10 Ambient operating temperature 14 F 10 C no frost to 122 F 50 C at ly 465 to 800 640 to 1100 Vdc 0 to 0 122 to 158 F 50 to 70 C derating required Frequency 50 60 Hz Storage temperature 40 F to 158 F 40 to 70 C Line voltage variation 10 to 10 Ni liquidiin heatsink under F 0 0 m um Input frequency variation 45 66 Hz Relative humidity 5 96 RH noncondensing no dripping water Conti Rated ling liquid Air quality Chemical vapors ontinuous output current iis 2 2 cooling ligui EC 721 3 3 unit in operation class 302 0 particles Out
77. 9 Disconnect H3 Y Y Weight Voltage 16 WI wa 3 W W 7 WS H1 H2 H3 01 02 03 04 05 Dia 1 Dia 2 Dia 3 Lbs kg 480 400 550 31 26 2 40 650 0 79 343 295 252 118 79 45 7480 2018 2370 11 22 1909 0 47 17 60 0 83 1 89 0 35x0 43 526 794 61 165 20 87 75 64 30 2018 1900 512 5 602 285 485 12 447 21 48 9x11 239 V6 T2 68 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives SVX9000 Drives Approximate Dimensions in Inches mm FR11 Open Chassis W3 W3 2 W2 do Y VIE 5 W2 W2 Yd Shown without terminal cover e o 0 o e 25 B H1 gt W1 Y 4 o 02 q D1 q Y Y Weight Voltage hp ly wi w2 w3 H1 H2 01 02 Lbs kg 480V 400 550 27 9 709 8 86 225 2 6 67 45 5 1155 33 5 850 19 8 503 18 4 468 833 378 575V 400 500 Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 4 V6 T2 69 2 4 Adjustable Frequency Drives 5 9000 Drives Appro
78. 95 Number of Input Units 480V Input 690V Input Catalog Number hp Modules Catalog Number hp Modules SPX800A0 4A2N1 800 2 SPX800A0 5A2N1 800 2 SPX900A0 5A2N1 900 2 SPXH10A0 5A2N1 1000 2 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 157 2 5 5 9000 Drives Approximate Dimensions Inches mm FR13 Open Chassis Converter 900 1000 hp 480V 1 W4 W4 W4 W4 WA e a 419 0096 m o o o o o o ra sh t Adjustable Frequency Drives w3 gt Dia 4 d 9 o e le Y 3 D lo y D7 D6 W1 gt L 151 LLL H 1 H YL T 1 r J los wi W W W W H H2 H3 H5 27 87 5 91 2665 457 335 41 54 246 3986 41 34 0 69 1469 051 0 73 6 42 01 02 03 D4 03 05 06 07 2 56 1 06 1 57 708 150 677 116 85 1055 62 5 1012 5 1050 17 5 373 13 18 5 163
79. Cover Plates Over Louvers For Cable Entry Top View Adjustable Frequency Drives SVX9000 Drives NEMA Type 1 IP21 NEMA Type 12 IP54 with 22 in Floor Stand la J FX AK 0 E 7 mmm A 33860 n 2 Places a bx a 7 B e gt lt 5 aj NEMA Type 1 IP21 NEMA Type 12 IP54 with 12 in Floor Stand For Cable For Cable For Cable Entry Entry Entry 4 0 44 11 2 Mounting pH Holes 6 Places A MM 1 0 0 V R gt gt JJ A Bottom View GG f lt ke LL HH Bottom View NEMA Type 1 IP21 Type 12 IP54 with Floor Stand For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G1 H J K 26 4 669 59 0 1499 19 4 492 24 8 630 57 0 1448 55 4 1406 4 0 102 3 0 76 Max Approx Cable Entry Door Clearance CB Handle Shipping Weight L M N P R S T V w Lbs kg 5 9 149 124 315 9 5 241 26 4 669 1 5 38 4 8 121 5 9 151 380 173 Stand X Y 2 BB CC DD EE FF GG HH JJ KK LL MM NN PP RR ss TT U
80. DIN3 Closed OK I 11 DIN1 DIN6 Common 12 24 Control Voltage Output 0 1 max 1 13 GND Ground 414 DINA Speed Select 0 100 Preset speed 415 DIN5 Fire Mode Contact closed fire mode 1 27 16 DING Force Bypass Contact closed bypass 17 CMB DIN1 DIN6 Common Terminal Block Layout 18 AO 1 Output Frequency 0 20 mA 19 1 Analog Output Common Ground EN 30 24Vdcin Auxiliary Input Voltage 21 22 23 32 33 o Analog RO1 RO1 2 A DATA RS 485 DATA Programmable BACnet d Modbus FLN N2 DATA RS 485 DATA 21 2 Slot B 12 13 14 15 16 17 18 19 3 A B efault Signa 22 RO1 24Vdc GND 1 AO1 24 Vdc RS 485 RS 485 __ DI1 6 in Data Data 23 24 Vdc 8A 1 2 3 4 5 6 7 8 9 10 11 DONGA 2 10 An Al2 Al2 24vde GND 25177 802 Drive Run 125 Vdc 0 4A 2 Vdc out DI1 6 26 32 33 RO3 Fault Factory Jumper External Interlock Standards Includes Reliability Digital inputs D1 D6 relay e Six digital input Pretested components out analog in out are freely Two analog input e Conformal coated programmed One analog output varnished boards The ae ue 1 Three output 40 rated Sg e INPUT tO mu pie RS 485
81. May 2014 www eaton com Adjustable Frequency Drives 2 5 SPX9000 Drives Dimensions Approximate Dimensions in Inches mm 9000X Drives Type 1 IP21 and Type 12 IP54 FR4 FR5 and FR6 lt W1 P lt D1 j 82 Tuo 3 gt e o AO AO H1 e H3 H2 I 5 J y R2 46 op Knockouts 97 9 03 2 Weight Knockouts at Inches mm Voltage hp ly H1 H2 H3 D1 D2 D3 wi w2 R1 Dia R2 Dia Lbs kg 0 D FR4 230V 3 4 3 12 9 12 3 11 5 75 3 0 5 0 5 04 3 9 0 5 0 3 11 0 5 3 at 10 1 28 1807 15 327 313 292 190 77 126 128 100 13 7 5 230V 5 7 1 2 16 5 16 0 15 3 8 4 3 9 5 8 5 7 3 9 0 5 0 3 17 9 8 2 at 1 5 37 480V 7 1 2 15 419 406 389 214 100 148 144 100 13 7 1 at 10 1 28 FR6 230V 10 15 22 0 21 3 20 4 9 3 4 2 6 5 77 5 8 0 6 0 4 40 8 19 3at 1 5 37 d 558 541 519 237 105 165 195 148 15 5 9 575V 2 25 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 145 2 5 Adjustable Frequency Drives SPX9000 Drives Approximate Dimensions in Inches mm NEMA 1 IP21 and NEMA Type 12 IP54 with Flange Kit FR4 FR5 and FR6
82. May 2014 www eaton com V6 T2 175 2 6 Adjustable Freguency Drives Series Drives H Max Series IntelliDisconnect 1 Disconnect Standard FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 6 HMX4D6A1NA 2 75 HMX7D5A1NA 3 11 HMX011A1NA 5 5 17 HMX017A1NA 75 25 HMX025A1NA 10 31 6 15 47 HMX047A1NA 20 60 HMX060A1NA 7 25 75 7 30 88 230 FS Drive Rated Frame Size Horsepower Amps Catalog Number 4 1 42 HMX4D2A2NA 2 6 8 HMX6D8A2NA 3 9 6 HMX9D6A2NA 5 5 15 2 HMX016A2NA 75 22 022 2 10 28 028 2 6 15 42 HMX042A2NA 20 54 HMX054A2NA 7 25 68 HMX068A2NA 30 80 080 2 480 FS Drive Rated Frame Size Horsepower Amps Catalog Number 4 1 21 HMX2D1A4NA 2 3 4 HMX3D4A4NA 3 5 6 HMX5D6A4NA 5 7 6 HMX7D6A4NA 75 1 HMX011A4NA 5 10 14 HMX014A4NA 15 21 HMX021A4NA 20 27 HMX027A4NA 6 25 34 HMX034A4NA 30 40 HMX040A4NA 40 52 HMX052A4NA 7 50 65 HMX065A4NA 60 77 HMX077A4NA 75 96 HMX096A4NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for specifics Enclosure size and weight differ from NEMA 1 and 12 products V6 T2 176 Volume 6 Solid State Motor Control 08100007
83. OOOOO Jl FS3 0 28 in 7 mm Y 3 0 ca O o Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 29 2 3 Adjustable Freguency Drives Series Adjustable Freguency Drives Approximate Dimensions Inches mm z Dimensions and Frame Sizes FS4 and FS5 FS Frame Size a 0 28 a1 20 0 A X ze 5e a OOOOOOOOO LS oft i 5 01 1 28 O 02 b1 V6 T2 30 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 3 Series Adjustable Freguency Drives Dimensions and Frame Sizes Approximate Dimensions inches mm Installation Part Number a al b b1 b2 c 0 01 02 Size 12 107 _ 2 60 1 50 6 30 5 79 1 26 4 02 0 18 FS1 12 204_ 66 38 160 147 32 102 4 5 MMX12AA2D8_ MMX32AA1D7_ MMX32AA2D4_ MMX32AA2D8_ MMX34AA1D3_ MMX34AA1D9_ MMX34AA2D4_ MMX11AA1D7_ 3 54 2 46 7 68 7 11 1 26 4 14 2 17 FS2 MMX11AA2D4_ 90 62 5 195 182 32 105 5 5 MMX11AA2D8_ MMX11AA3D7_ MMX12AA3D7_ MMX12AA4D8_ MMX12AA7D0_ MMX32AA3D7_ MMX32AA4D8_ MMX32AA7D0_ MMX34AA3D3_ MMX34
84. Ohms Catalog Number Dimensions Inches Catalog Number Dimensions Inches 0 75 30 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 2W x 7D x 5H 1 30 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 2W x 7D x 5H 15 30 0 DBR R100 W0400 12W x 5D x 5H DBR R036 W1200 2W x 10D x 5H 2 30 0 DBR R100 W0400 12W x 5D x 5H DBR R036 W1200 2W x 10D x 5H 3 30 0 DBR R036 W0800 12W x 7D x 5H DBR R036 W2000 2W x 16D x 5H 4 30 0 DBR R036 W0800 12W x 7D x 5H DBR R030 W2400 9W x 10D x 5H 5 30 0 DBR R036 W0800 12W x 7D x 5H DBR R030 W2800 9W x 13D x 5H 75 20 0 DBR R020 W1200 12W x 10D x5H DBR R020 W4800 26 5W x 13D x 5H 10 10 0 DBR R015 W1600 12W x 13D x5H DBR R112 W6000 26 5W x 13D x 5H 15 10 0 DBR R012 W2400 19W x 10D x5H DBR R010 W9000 28W x 10D x 10H 20 3 3 DBR R9D3 W3200 19W x 10D x5H DBR R3D4 W012K 28W x 10D x 10H 25 3 3 DBR R5D5 W4000 26 5W x 10D x 5H DBR R5D1 W015K 28W x 16D x 10H 30 3 3 DBR R4D8 W4800 26 5W x 10D x 5H DBR R4D1 W020K 28W x 16D x 10H 40 14 DBR R004 W6000 26 5W x 13D x 5H DBR R3D4 W025K 30W x 18D x 16H 50 14 DBR R3D1 W7500 26 5W x 16D x 5H DBR R2D1 W030K 30W x 18D x 24H 60 14 DBR R2D8 W9000 26 5W x 16D x 5H DBR R002 W036K 30W x 18D x 24H 75 14 DBR R2D6 W012K 28W x 10D x 10H DBR R1D5 W045K 30W x 18D x 32H 100 14 DBR R002 W015K 28W x 16D x 10H DBR R1D4 W060K 30W x 18D x 40H V6 T2 46 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 480 Brake Resistors 20 Duty 100 Torgue Drive hp Minimum Ohms
85. P P e e H1 e e p H3 R1 01 gt Front Side Weight Voltage Amps H1 H2 H3 01 wi w2 W3 R1 Dia R2 Dia Lbs kg 380 500 Vac 16 61 16 97 0 53 0 59 9 69 6 30 4 80 4 80 0 39 0 35 66 30 431 0 13 5 15 0 246 0 160 0 122 0 122 0 10 0 9 0 Chassis Size lt W1 H2 Wee ka RE o A 1 N R e e H1 OL TO X TOL To To Jo H3 9 9 6 5 W3 R1 D1 Right Side Front Left Side Borom Weight Voltage Amps H1 H2 H3 D1 wi W2 W3 R1 Dia R2 Dia Lbs kg 380 500 72 140 19 41 0 49 1 77 10 14 7 60 3 35 5 24 0 39 77 35 493 0 12 5 45 0 257 5 193 0 85 0 133 0 10 0 V6 T2 262 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 09 LCX9000 Drives Approximate Dimen
86. R rw im 2 2 o 2 e e 1 H2 H2 H3 H H3 H5 H4 yy a lt W2 lt W1 gt ke gt lt D1 gt W3 D2 LA in m E D1 s e 7 BUT Approximate Approximate Weight Shipping Weight H H1 H2 H3 H4 H5 w W1 W2 w3 D D1 D2 Lbs kg Lbs kg 58 09 56 45 54 77 48 35 78 09 77 64 37 73 30 92 29 30 3 34 17 74 16 77 3 31 370 168 485 220 1475 5 14338 1391 2 12281 19835 19721 9583 7854 7442 848 450 6 426 0 84 1 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 215 2 7 Adjustable Freguency Drives 9000 Drives Approximate Dimensions in Inches mm Enclosure Size D UL Type 3R wi 0 44 11 2 D1 w2 gt Mounting Holes Ti two places 4 a H1 e e le Y Approximate Shipping Weight H H1 w W1 W2 D D1 Lbs kg 76 27 96 00 30 92 37 73 29 30 16 76 17 74 1000 454 1937 3 2438 4 784 4 958 3 744 2 424 7 450 6 Shown with optional floor stands V6 T2 216 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 7 CFX9000 Drives Approximate Dimensions in Inches mm Enclosure Size F
87. Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 6 2 9 2 2 Adjustable Freguency Drives PowerXL DC1 DA1 Series Adjustable Frequency Drives Product Selection 2 ro _ _DC1 Series IP20 Enclosure Drives 100 Continuous Frame hp O kW Volts Current In A Size 9 Catalog Number 05 037 115V single phase in 7 1 DC1 S17DONN A20N 075 055 J SV single phase out 105 2 DC1 S1011NB A20N 05 037 200 240V single phase in 43 1 DC1 S24D3NN A20N 1 075 200 2301 single phase out 7 1 DC1 S27DONN A20N 15 1 1 10 2 DC1 S2011NB A20N LOS 0 5 0 37 115V single phase in 23 1 DC1 1D2D3NN A20N 1 05 43 1 DC1 1D4D3NN A20N 15 11 58 2 DC1 1D5D8NB A20N 05 037 200 240V single phase in 23 1 DC1 122D3NN A20N 1 0 75 43 1 DC1 124D3NN A20N 2 15 7 1 DC1 127D0NN A20N 2 15 7 2 DC1 127D0NB AZ0N 3 22 105 2 DC1 12011NB A20N 5 4 15 3 DC1 12015NB A20N 05 0 37 200 240V three phase in 23 1 DC1 322D3NN A20N to agp 43 1 DC1 324D3NN A20N 2 15 7 1 DC1 327D0NN A20N 2 15 7 2 DC1 327D0NB A20N 3 22 105 2 DC1 32011NB A20N 5 4 18 3 DC1 32018NB A20N 1 0 75 380 480 three phase in 22 1 DC1 342D2NN A20N 2 15 41 1 DC1 344D1NN A20N 2 15 41 2 DC1 344D1NB A20N 3 22 58 2 DC1 345D8NB A20N 5 4 95 2 DC1 349D5NB A20N 75 55 14 3 DC1 34014NB A20N 10 75 18 3 DC1 34018NB A20N 15 11 24 3
88. Y P 5 lt w gt D1 1 lt D gt Approximate Approximate Weight Shipping Weight H H1 H2 H3 H4 w W1 D D1 Lbs kg Lbs kg 52 00 50 00 48 35 72 00 71 19 30 92 29 30 16 78 2 34 320 145 435 197 1320 8 1270 0 1228 1 1828 8 1808 2 785 4 744 2 426 2 59 4 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 213 2 7 Adjustable Freguency Drives 9000 Drives Approximate Dimensions Inches mm Enclosure Size B UL Type 3R 2 w 0 44 11 2 Mounting Holes 4 Places Approximate Approximate Weight Shipping Weight H H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs kg Lbs kg 46 09 44 45 42 77 36 35 26 31 20 92 19 30 2 69 17 74 16 76 3 31 235 107 290 132 1170 7 1129 0 1086 4 923 3 668 3 531 4 490 2 68 3 450 6 425 7 84 1 V6 T2 214 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 7 CFX9000 Drives Approximate Dimensions in Inches mm Enclosure Size C UL Type 3R 0 44 11 2 Mounting Holes Ma le 4 Places 5 w gt 4 Places lt w gt D wa D a gt Tl i
89. factory Complete range of control network and power options Horsepower range e 208V 3 4 to 100 hp ly 1 to 100 hp lj e 230V 3 4 to 100 hp ly 1 to 100 hp lj e 480V 1 to 700 hp lp 1 1 2 to 800 hp Padlockable disconnect 2 4 V6 T2 36 V6 T2 76 V6 T2 77 V6 T2 78 V6 T2 82 V6 T2 86 V6 T2 88 V6 T2 99 Standards and Certifications UL Listed cUL Listed W W Listed Volume 6 Solid State Motor Control 08100007 2014 www eaton com Listed V6 T2 75 2 4 Adjustable Freguency Drives 9000 Drives Product Identification Enclosed 9000 Series Drive 1 1 Door mounted keypad included as standard with bypass option 2 5 9000 variable frequency drive 3 Input disconnect Output contactor Option PE included as standard with bypass option Bypass contactor Option RA 5 Option Option RB 4 Input line fuses Overload relay tion P3 Option PH 5 Input contactor included as e Option PI standard with bypass option V6 T2 76 Volume 6 Solid State Motor Control 9 115V control transformer Option KB 10 Bypass pilot lights and selector switches Option RA Option RB Option L2 Option KF 11 Customer control and signal connection terminal block 12 Control relay CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Catalog Number Selection SVX9000 Enclosed NEMA Type 1 IP21 an
90. kg FS8 230 Vac 50 75 37 55 140 205 13 76 38 02 37 26 37 26 11 2 9 29 1 42 154 3 180 Vac 100 150 75 110 349 6 965 7 946 4 946 4 290 1 236 0 36 0 70 FS9 230 Vac 100 120 75 90 261 310 14 63 33 09 31 89 31 89 18 90 15 75 1 57 238 1 180 Vac 200 250 132 160 371 6 890 4 810 0 810 0 480 0 400 0 40 0 108 Note For flange dimension please reference User Manual V6 T2 170 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives IntelliPass and IntelliDisconnect Drives H Max IntelliPass and IntelliDisconnect Drives Product Description The IntelliPass electronic bypass is a two or optional three contactor design using a 24 Vdc XT Series contactor with an optional manual override switch that allows the unit to run in bypass without the H Max Series drive The IntelliPass software parameters utilize engineering units common to the HVAC industry Onboard startup wizard guarantees flawless commissioning with plug and play screen entry Avallable in NEMA UL Type 1 Type 12 and Type 3R with optional pre engineered operator devices to meet all customized specification requirements The IntelliPass construction features allow for easy installation reliable operation and serviceability with additional onboard wire space and removable conduit plates with knockouts Features and Benefits Industry leading energy savi
91. of nominal 5 nS m 120 ohms line termination resistors required for installation Adjustable Frequency Drives SVX9000 Drives DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The N2 fieldbus is available as a factory installed option and as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable over Ethernet using a supplied software tool Volume 6 Solid State Motor Control 08100007 2014 www eaton com BACnet Network Communications The B
92. right 1 0000005 0000005 Bus capacitor 12 00335 00336 Inverter Rectifier module 1 FR10823 FR10823 Charging resistor 1 00066 00066 Diode 3 01177 01177 Rectifier board 1 00591 00592 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 1 FR10846 FR10846 Fan assembly right 1 FR10847 FR10847 Fan AC 2 01080 01080 Fan fuse 4 PP20202 PP20202 Starting cap 2 S00528 S00528 Fan driver board AC 2 VB00299 VB00299 solation transformer left 1 FR10844 FR10844 solation transformer right 1 FR10845 FR10845 Main DC fan DC fan 2 PP00072 00072 DC power supply 2 01017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 53 Adjustable Freguency Drives SVX9000 Drives 2 4 FR11 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 1 00451 00451 ASIC board 1 00457 00457 Control ASIC fan 1 PP01096 PP01096 Control module SVX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2
93. 1 Analog input current 0 4 20 mA 250 ohm differential Digital inputs 6 positive or negative logic 18 24 Auxiliary voltage 24V 15 max 250 mA Output reference voltage 10V 3 max load 10 mA Analog output 0 4 20 mA R max 500 ohm Resolution 10 bits accuracy 2 Digital outputs Open collector output 50 mA 48V Relay outputs Two programmable change over relay outputs Switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Min switching load 5V 10 mA Note Derating required if higher switching frequency than the default is used CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 9 LCX9000 Drives LCX9000 Products continued Description Specification Description Specification Protections Protections continued Overvoltage protection Overcurrent protection Yes 480V 911V Motor overload protection Yes 575V 1200V Motor stall protection Yes Undervoltage protection Motor underload protection Yes 480V 333V Short circuit protection Yes 24V and 10V reference voltages 575V 461V Liquid Cooling Ground fault protection In case of ground fault in motor or motor cable Allowed cooling agents Drinking water only the drive is protected Water glycol mixture Mains supervision Trips if any of the input phases are missing drives only Temperature of cooling agent 32 to 86 F 0 to 30 C at
94. 1 110V 110 115 10 2 230V 200 240V 10 4 460 380 480V 10 Brake D 110V input 230V output voltage doubler N No internal brake chopper B Brake chopper Rated Operational Current EMC Radio Interference Suppression Filter Examples 2D2 2 2A N internal filter 4D1 4 1A F Internal filter 024 24A DA1 Series Adjustable Frequency AC Drives DAT 1 2 4D1 F B A 20 Sm Device Series Type DA1 Variable frequency drive compact Series 1 C Coated printed circuit boards D Drives A Advanced 1 Series 1 Degree of Protection Connection in Power Section 20 IP20 NEMA 0 1 Single phase mains connection three phase motor connection 66 IP66 NEMA 4 3 Three phase mains connection three phase motor connection 6S IP66 with disconnect NEMA 4 Mains Voltage Category Display Unit Display 2 230V 200 240V 10 LED display 4 400V 380 480V 10 5 575V 500 600V 10 Rated Operational Examples EMC Radio Interference Suppression Filter 2D2 2 2A F Internal RFI filter 4D1 4 1A 024 24A
95. 1 Opening for m Bottom Cable Entry 12 50 22 47 570 74 3175 t 9 773 5 48 139 19 EJ 196 34 Approximate Construction UL Type 1 Oversize lt 3 01 76 45 Shipping Weight Finish Enclosure ANSI 61 Gray Light lt 3147 951 74 Lbs kg 45 22 1148 59 _ gt Bottom View 1400 636 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 219 2 Adjustable Freguency Drives 9000 Drives Approximate Dimensions Inches mm Enclosure Size 9 1 50 38 1 two 93 50 2374 9 90 00 2286 0 Access Plate ak O lt 24 00 609 6 gt I 25 14 638 6 gt Side View 00 56 514 2 Dia Mounting Hole five places 18 84 478 5 Finish Enclosure ANSI 61 Gray light Material Enclosure and Backplate 12 ga 0 1046 Cold Rolled Steel V6 T2 220 2 00 50 8 gt lt 22 90 581 7 gt Volume 6 Solid State Motor Control 5 43 50 1104 9 gt lt T b 7 46 x 15 00 S 189 5 3810 NG Access 8 75 222 3 4 90 Max Door Opening 4 a 737 4 00 101 6 Minimum Free Air Space Required
96. 10 135 SPX007A2 5A4N1 10 135 15 18 SPX010A2 5A4N1 15 18 20 22 SPX015A2 5A4N1 20 22 25 27 SPX020A2 5A4N1 25 27 30 34 SPX025A2 5A4N1 FRZ 30 34 40 4 SPX030A2 5A4N1 40 4 50 52 SPX040A2 5A4N1 FRB 50 52 60 62 SPX050A2 5A4N1 60 62 75 80 SPX060A2 5A4N1 75 80 100 100 SPX075A2 5A4N1 FR 100 100 125 125 SPX100A2 5A4N1 125 125 150 144 SPX125A2 5A4N1 150 144 170 SPX150A2 5A4N1 170 200 208 SPX175A2 5A4N1 525 690 Type 12 1 54 Freestanding Drives Frame Size hp 16 Current ly hp 1 Current 11 Catalog Number FR10 200 208 250 261 SPX200A2 5A4N1 250 261 300 325 SPX250A2 5A4N1 300 325 400 385 SPX300A2 5A4N1 525 690 Open Chassis Drives Frame Size hp ly Current ly hp 1 Current I Catalog Number FR10 200 208 250 261 SPX200A0 5A2N1 250 261 300 325 SPX250A0 5A2N1 300 325 400 385 SPX300A0 5A2N1 FR11 400 385 450 460 SPX400A0 5A2N1 450 460 500 502 SPX450A0 5A2N1 500 502 590 SPX500A0 5A2N1 FR12 590 600 650 SPX550A0 5A2N1 600 650 700 750 SPX600A0 5A2N1 700 750 800 820 SPX700A0 5A2N1 FR13 800 820 900 920 SPX800A0 5A2N1 900 920 1000 1030 SPX900A0 5A2N1 1000 1030 1250 1180 SPXH10A0 5A2N1 FR14 1350 1300 1500 1500 SPXH13A0 5A2N1 1500 1500 2000 1900 SPXH15A0 5A2N1 2000 1900 2300 2250 SPXH20A0 5A2N1 Notes Integrated fuses as standard Limited option selection available 115V transformer KB light kit L1 HOA speed potentiometer
97. 100 FRO CPX10015DA 125 125 FRO CPX12515DA 150 144 FRO CPX15015DA 9 200 208 FR10 20015 250 261 FR10 CPX25015DA 300 325 FR10 CPX30015DA 10 400 385 FR11 40015 450 460 FR11 45015 500 502 FR11 CPX50015DA 11 600 590 FR12 CPX60015DA 650 650 FR12 CPX65015DA 700 750 FR12 CPX70015DA Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure V6 T2 234 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 8 9000 Drives GPX9000 Drive 9000 Base Drive NEMA 12 Filtered Enclosure Current Chassis Base Catalog Size hp O A Frame Number Low Overload Drive 7 25 27 FR6 CPX02565AA 30 34 FR6 CPX03065AA 40 41 FR7 CPX04065AA 50 52 FR7 CPX05065AA 60 62 FR8 CPX06065AA 75 80 FR8 CPX07565AA 100 100 FR8 CPX10065AA 8 125 125 FRO CPX12565AA 150 144 FRO CPX15065AA 200 208 FRO CPX20065AA 9 250 261 FR10 CPX25065AA 300 325 FR10 CPX30065AA 400 385 FR10 CPX40065AA 10 500 502 FR11 CPX50065AA 600 590 FR11 CPX60065AA 11 650 650 FR12 CPX65065AA 700 750 FR12 CPX70065AA 800 820 FR12 CPX80065AA High Overload Drive 7 25 27 FR6 CPX
98. 12 in Converts a Size C or D normally wall mounted enclosure to a floor standing enclosure with a height of 12 in 304 8 mm Enclosure S9 Space Heater Prevents condensation from forming in the enclosure when the drive is inactive or in storage Includes a thermostat for variable temperature control Enclosure Heater requires a customer supplied 115V remote supply source Enclosed Drive Options Conformal Varnished Coating Control Options Chassis Delivery Chassis Delivery Catalog Frame Code Frame Code Description Number Suffix FR6 FP FR9 FP Door mounted speed potentiometer K1 FR7 FP FR10 FP Door mounted speed potentiometer with HOA selector switch K2 FR8 FP FR11 FP 3 15 psig follower K3 FR12 FP selector switch K4 MANUAL AUTO reference switch K5 o START STOP pushbuttons Light Options 9 p Type D2 control relay SD Catalog Description Number Suffix On delay relay SE Power on run fault LED lights 22 mm L1 Off delay relay SF Power on fault LED lights 22 mm 13 Additional terminal blocks per 4 points 0 Green LED run light 22 LA Note Green LED stop light 22 mm LD See catalog number description to order Red LED run light 22 mm LE Red LED stop light 22 mm LF Red LED fault light 22 mm LG Power on white LED light 22 mm LJ Miscellaneous LED light 22 mm LU Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 207 2 7 9000 Drives Bypass Control Options Adjustable
99. 125 125 FRO CPX12535DA 150 144 FRO CPX15035DA Notes All Type drives use the Size F enclosure See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure V6 T2 236 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 8 9000 Drives Options 9000 Series Option Board Kits 9000 Series drives accommodate wide selection of adapter option boards to customize the drive for your application needs drive s control unit is designed to accept total of five option boards see figure below The CPX9000 Series factory installed standard board configuration includes A9 I O board 2 relay output board which are installed in slots and 9000X Series 0ption Board Kits Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard I O Cards 2 RO NC NO B OPTA2 6 DI 1 DO 2 Al TAO 1 10 ref
100. 1992 transients guidelines Cannot retrofit for most AFDs Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 193 2 9000 Drives 4 Clean Power Drives When the total load is comprised of non linear load such as drives and the ratio is lsc l_ the greatest harmonic mitigation is required Under these conditions the currents drawn from the supply need to be sinusoidal and clean such that system interference and additional losses are negligible Eaton s CPX9000 clean power drive uses a phase shifting auto transformer with delta connected winding that carries only the ampere turns caused by the difference in load currents This results in nine separate phases In this type of configuration the Basic 18 Pulse Rectifier with Phase Shifting Auto Transformer 18 Pulse SCR Bridge Rectifier Converter Section Adjustable Frequency Drives total kVA rating of the transformer magnetic system was only 48 that of the motor load A traditional isolated transformer system with multipulse windings would require the full kVA rating to be supported which is more common in an MV step down transformer Inverter Section Pre charge Circuit 18 Pulse Phase Shifting 3 Phase AC Input Diode Rectifiers Auto Transformer The integrated 18 pulse clean power drive with near sine w
101. 1992 Harmonic Distortion Limits What Are Linear Loads Linear loads are primarily devices that run across the line and do not add harmonics Motors are prime examples The downside to having large motor linear loads is that they draw more energy than a VFD because of their inability to control motor speed In most applications there is a turn down valve used with the motor that will reduce the flow of the material without significantly reducing the load to the motor While this provides some measure of speed control it is extremely inefficient Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Why Be Concerned About Harmonics 1 Installation utility costs increase Harmonics cause damage to transformers and lower efficiencies due to the loss These losses can become significant and can have a dramatic effect on the HVAC systems that are controlling the temperatures of the building where the transformer and drive equipment reside Downtime and loss of productivity Telephones and data transmissions links may not be guaranteed to work on the same power grids polluted with harmonics Downtime and nuisance trips of drives and other equipment Emergency generators have up to three times the impedance that is found in a conventional utility source Thus the harmonic voltage distortion can be up to three times as large causing risk of operation problems Large
102. 3 5 0 16 4 2 0 33 8 5 10 36 4 7 253 8 29 210 5 7 78 197 5 12 20 310 0 9 90 251 5 1 31 33 4 9 21 234 0 0 14 3 5 0 16 4 2 0 33 8 5 17 42 7 9 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 19 2 2 Adjustable Frequency Drives PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Approximate Dimensions in Inches mm Sizes FS1 FS3 Degree of Protection IP66 NEMA 4 with Local Controls lt 01 02 B B1 B1 Y B2 lt A1 gt lt C1 gt lt c Weight Size A A1 B B1 B2 C1 01 02 Ibs kg FS1 6 34 161 0 5 85 148 5 9 13 232 0 7 44 189 0 0 98 25 0 7 24 184 0 0 14 3 5 0 15 4 0 0 31 8 0 6 17 2 8 FS2 7 40 188 0 6 93 176 0 10 12 257 0 7 87 200 0 1 12 28 5 7 58 192 0 0 14 3 5 0 16 4 2 0 33 8 5 11 02 5 0 253 8 29 210 5 7 78 197 5 12 20 310 0 9 90 251 5 1 31 33 4 9 21 234 0 0 14 3 5 0 16 4 2 0 33 8 5 18 08 8 2 V6 T2 20 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency Drives Approximate Dimensions in Inches mm DA1 Sizes FS2 and FS3 Degree of Protection 20 0 4 01 lt 02 Weight Size A A1 B B1 B2
103. 31 SVX01012BA SVX01022BA 1 15 48 6 SVX01512BA 6 SVX01522BA 20 61 SVX02012BA SVX02022BA 2 25 75 7 SVX02512AA 7 SVX02522AA 30 88 SVX03012AA SVX03022AA 40 114 SVX04012AA SVX04022AA 3 50 140 8 SVX05012AA 8 SVX05022AA 4 60 170 8 SVX06012AA 8 SVX06022AA 5 75 205 8 SVX07512AA 8 SVX07522AA 100 261 9 SVX10012AA 9 SVX10022AA Notes For brake chopper options see Page V6 T2 46 See enclosure dimensions starting on Page V6 T2 88 Includes drive local remote keypad and enclosure This unit is current rated 100 hp 100 amps 261 Ii hp It is not hp rated They do not meet NEC ampere ratings Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 79 2 4 Adjustable Freguency Drives 5 9000 Drives 480V Drives SVX9000 Enclosed Enclosed Input Base Drives c Drives NEMA Type 1 IP21 NEMA Type 12 IP54 Enclosure Frame Base Catalog Frame Base Catalog Size hp Current Size Number Size Number High Overload Drive and Enclosure 0 1 2 2 4 SVX00114EA 4 SVX00124EA 1 1 2 33 SVXF1514EA SVXF1524EA 2 4 3 SVX00214EA SVX00224EA 3 5 6 SVX00314EA SVX00324EA 5 7 6 SVX00514EA SVX00524EA 7 1 2 12 5 SVX00714EA 5 SVX00724EA 10 16 SVX01014EA SVX01024EA 15 23 SVX01514EA SVX01524EA 1 20 31 6 SVX02014EA 6 SVX02024EA 25 38 SVX02514EA SVX02524EA SVXO3014EA SVX03024EA 2 40 61 7 SVX04014DA 7 SVX04024DA 50 72 SVX05014DA SVX05024DA 60 87 SVX06014DA SVX
104. 5 7 5 7 1 2 10 SPX005A1 5A4N1 7 1 2 10 10 13 5 SPX007A1 5A4N1 10 13 5 15 18 SPX010A1 5A4N1 15 18 20 22 SPX015A1 5A4N1 20 22 25 2 SPX020A1 5A4N1 25 2 30 34 SPX025A1 5A4N1 FR7 30 34 40 4 SPX030A1 5A4N1 40 41 50 52 SPX040A1 5A4N1 FR8 50 52 60 62 SPX050A1 5A4N1 60 62 75 80 SPX060A1 5A4N1 75 80 100 100 SPX075A1 5A4N1 FR9 100 100 125 125 SPX100A1 5A4N1 125 125 150 144 SPX125A1 5A4N1 150 144 170 SPX150A1 5A4N1 170 200 208 SPX175A1 5A4N1 525 690V NEMA Type 1 IP21 Freestanding Drives Frame Size hp ly Current ly hp 14 Current Catalog Number FR10 200 208 250 261 SPX200A1 5A4N1 250 261 300 325 SPX250A1 5A4N1 300 325 400 385 SPX300A1 5A4N1 FR11 400 385 450 460 SPX400A1 5A4N1 450 460 500 502 SPX450A1 5A4N1 500 502 550 590 SPX500A1 5A4N1 Note Integrated fuses as standard Limited option selection available 115V transformer KB light kit L1 HOA 4 speed potentiometer w HOA K2 disconnect switch P2 See Freestanding Option selection on Page V6 T2 134 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 125 2 5 Adjustable Frequency Drives SPX9000 Drives PX8000 Open Drives 525 690 NEMA Type 12 IP54 Drives Frame EE hp ly Current ly hp Ij Current Catalog Number Q caaaeaee a e FRG 2 33 3 45 SPX002A2 5A4N1 eu 3 45 55 SPX003A2 5A4N1 55 5 15 SPX004A2 5A4N1 5 75 71 2 10 SPX005A2 5A4N1 7 1 2 10
105. 5 Adjustable Frequency Drives SPX9000 Drives Control Panel Options Factory Options Factory Installed Description Option Code Local Remote Keypad SVX9000 Control Panel This option is standard on all drives and A consists of an RS 232 connection backlit alphanumeric LCD display with nine indicators for the RUN status and two indicators for the control source The nine pushbuttons on the panel are used for panel programming and monitoring of all SVX9000 parameters The panel is detachable and isolated from the input line potential Include LOC REM key to choose control location Field Installed NEMA Type 1 IP21 Catalog Number KEYPAD LOC REM Keypad Remote Mounting Kit This option is used to remote mount the SVX9000 keypad The footprint is compatible to the SV9000 remote mount kit Includes 10 ft cable keypad holder and mounting hardware OPTRMT KIT 9000X Keypad Blank 9000X Series select keypad for use with special and custom applications KEYPAD BLANK Miscellaneous Options Description 9000XDrive A PC based tool for controlling and monitoring of the SVX9000 Features include loading parameters that can be saved to a file or printed setting references starting and stopping the motor monitoring signals in graphical or text form and real time display To avoid damage to the drive or computer SVDrivecable must be used Catalog Number 9000XDRIVE SVDrivecable ft 1 8m RS 232 cable
106. 6 685 8 643 9 429 8 388 6 413 0 59 4 V6 T2 112 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Enclosure Box NEMA 12 IP54 2 4 00 101 6 3 00 76 2 Minimum Free Air Minimum Air X ta Space Required 6 Space 7 n Required Both Sides x 5 1 H2 9 H Y 0 44 11 2 Y 8 Mounting Holes W1 4 Places lt w gt gt D1 l lt D gt EE o Approx Approx Voltage hp hp Weight Shipping Weight AC lu I H H1 H2 w W1 D D1 Lbs kg Lbs kg Three Phase 208V 15 25 20 30 40 00 38 00 36 35 20 92 19 30 16 76 2 34 185 84 229 104 2301 15 25 20 30 1016 0 965 2 923 3 531 4 490 2 425 7 59 4 480V 30 60 40 75 Single Phase 230V 15 20 40 00 38 00 36 35 20 92 19 30 16 76 2 34 185 84 229 104 1801 25 30 1016 0 965 2 923 3 531 4 490 2 425 7 59 4 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 113 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions in Inches mm Enclosure Box C Type 12 IP54
107. 6 Adjustable Freguency Drives Series Drives H Max Series IntelliDisconnect NEMA Type 3R Main Disconnect Standard 208 Vac FS Drive Rated Frame Size Horsepower Amps Catalog Number 4 1 4 6 HMX4D6C1NA 2 75 705 1 3 1 HMX011C1NA 5 5 17 HMX017C1NA 75 25 HMX025C1NA 10 31 HMX031C1NA 6 15 47 HMX047C1NA 20 60 HMX060C1NA 7 25 75 HMX075C1NA 30 88 HMX088C1NA 230 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 2 HMX4D2C2NA 2 6 8 HMX6D8C2NA 3 9 6 HMX9D6C2NA 5 5 15 2 HMX016C2NA 75 22 022 2 10 28 028 2 6 15 42 HMX042C2NA 20 54 HMX054C2NA 7 25 68 HMX068C2NA 30 80 HMX080C2NA 480 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 21 HMX2D1C4NA 2 3 4 HMX3D4C4NA 3 5 6 HMX5D6C4NA 5 7 6 HMX7D6C4NA 75 1 HMX011C4NA 5 10 14 HMX014C4NA 15 21 HMX021C4NA 20 27 HMX027C4NA 6 25 34 HMX034C4NA 30 40 HMX040C4NA 40 52 052 4 7 50 65 HMX065C4NA 60 77 HMX077C4NA 75 96 HMX096C4NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for specifics Enclosure size and weight differ from NEMA 1 and 12 products 6 2 178 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Onboard Network Communic
108. 600 Di gt lt D gt r lt D2 gt lt E gt Bottom View For reference only dimensions are subject to change See Page V6 T2 80 notes 3 and 5 for enclosure and option selection Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 60 0 1524 90 0 2286 260 1 664 22 9 582 20 51 30 0 762 44 3 1125 10 6 270 10 6 270 8 2 208 4 0 102 Max Approx Cable Entry Shipping Weight L M N P R S T U V w RR ss TT UU Lbs kg 8 5 32 7 12 0 11 9 9 8 1 5 43 5 15 0 7 5 25 0 93 5 274 290 1 270 1 2500 1135 216 831 305 303 249 38 1105 381 191 635 2375 696 738 687 V6 T2 98 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives SVX9000 VFD Pump Panels SVX9000 VFD Pump Panels Product Description Standard Enclosed covers a wide range of the most commonly ordered options Pre engineering eliminates the lead time normally associated with customer specific options Modified Standard Enclosed applies to specific customer requirements that vary from the Standard Enclosed offering such as the need for an additional indicating light or minor modifications to drawings Consult your Eaton representative for assistance in pricing and lead time Custom Engineered for those applications with more unique or complex requirements these are individually engineered to the custo
109. 65 27 40 5 91 150 09 2 5 24 0 35 0 59 0 18 133 9x15 4 6 3 0 51 13 Dia Weight 4 Lbs kg 0 37 443 201 8 5 Number of Input Units 480V Input Catalog Number hp Modules SPX900A0 4A2N1 900 3 SPXH10A0 4A2N1 1000 3 V6 T2 158 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 5 SPX9000 Drives Approximate Dimensions in Inches mm AC Choke Dimensions Choke Types Catalog Number Frame Size Choke Type Catalog Number Frame Size Choke Type Voltage Range 380 500V Voltage Range 525 690V SPX2504 FR10 CHK0400 SPX 2005 FR10 CHK0261 SPX 300 4 CHK0520 SPX 2505 CHK0400 SPX3504 CHK0520 SPX 3005 CHK0400 SPX 4004 FR11 2 x CHK0400 SPX 4005 FR11 CHK0520 SPX 5004 2 x CHK0400 SPX 4505 CHK0520 5 550 4 2 x CHK0400 SPX 500 5 2 CHK0400 SPX 600 4 FR12 2 x CHK0520 SPX5505 FR12 2 x CHK0400 SPX 650 4 2 x CHK0520 SPX 600 5 2 x CHK0400 SPK 7004 2 CHK0520 SPX 700 5 2 x CHK0400 SPX 800 4 FR13 2 x CHK0400 SPX 800 5
110. 92 19 30 2 69 17 74 16 76 3 31 235 107 290 132 230v 15 1170 7 11290 1086 4 9233 668 3 531 4 490 2 68 3 450 6 425 7 84 1 480V 25 40 V6 T2 186 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 6 H Max Series Drives Approximate Dimensions in Inches mm Enclosure Box 0 44 11 2 Mounting Holes Mae 4 Places gt w gt 4 Places lt A D W2 1 lt D gt EE n 5 al 2 2 A 2 8 Gs P H1 H2 H2 H3 H H3 y n vy lt w2 J HW gt lt W1 gt lt 01 lt 1 gt gt lt 01 2 02 LA II ID Voltage hp Weight AC I H H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs kg Three Phase 208 20 30 58 09 56 45 54 77 48 35 37 73 30 92 29 30 3 34 17 74 16 77 3 31 230 20 30 1475 5 1433 8 1391 2 1228 1 958 3 785 4 744 2 84 8 450 6 426 0 84 1 480 50 75 Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 187 Adjustable Fre
111. A gt s lt gt Bottom View For reference only dimensions are subject to change See Page V6 T2 80 notes 3 and 5 for enclosure and option selection Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 48 0 1219 90 0 2286 24 0 610 4220072 3 0 77 5 5 139 84 4 2143 4 0 102 Max Aj pprox Cable Entry Shipping Weight L M N P R S T U V w RR ss TT UU Lbs kg 1 12 5 7 83 13 31 0 21 5 213 93 5 2000 908 241 952 318 196 210 32 787 545 541 2375 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 97 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm Size 9 Access in Top 2 Places Openings Filtered for NEMA Type 12 IP54 Design Drive Circuit Breaker Key Locking Handle WA y g Access a Biases NL r P IN _ lt gt Side View Front View HL Bottom Access 0 56 14 2 Dia w _ d EDEN P IHhp ILhp 1 480V 400 500 G1 500 550 Y 550
112. B 5 485 signal communication jom Analog signal 2 actual value P 0 4 20 mA Ri 200k ohms 5 GND 0 signal ground 13 GND signal ground 14 DI4 Digital input 4 Preset speed B1 P 0 30V Ri 12k ohms min 05 Digital input 5 Fault reset P 0 30 Ri 12k ohms min Analog L 16 DIG Digital input 6 Disable PI contr P 0 30V Ri 12k ohms min 18 AO Analog output Output frequency P 0 2 10V RL 500 ohms 20 DO Digital signal out Active READY P Open collector max load 48V 50 mA 22 011 Relay out 1 Active RUN P Max switching load 250 Vac 2A or 250 Vdc 0 4A 23 R012 24 R021 Relay out 2 Active FAULT P Max switching load 250 Vac 2A or 250 Vdc 0 4A 25 R022 26 R023 Note P Parameter selectable function V6 T2 28 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 3 M Max Series Adjustable Frequency AC Drives Dimensions Approximate Dimensions in Inches mm Dimensions and Frame Sizes FS1 FS3 FS Frame Size a a a 1 1 1 gt 0 0 0 4 AN 4 A a 2 2 D a Us Of 000 T Y OOO OOOOO FS1 FS2
113. EXT 24 Vdc B5 3 RO NO B8 1 ext 24 Vdc EXT 24 Vdc 3 Pt100 Brake Chopper Options N brake chopper circuit B Internal brake chopper circuit B9 1 RO NO 5 DI 42 240 Vac input Communication Cards CA Johnson Controls 2 CI Modbus CJ BACne CQ EtherNet IP Input Options D 1 Three phase H 2 Three phase EMC N 4 Three phase L C2 Modbus C3 PROFIBUS DP C4 LonWorks C5 PROFIBUS DP 09 connector Keypad A Alphanumeric C6 CANopen slave Enclosure Voltage Rating 0 Chassis 2 230V 208 240 1 Type 1 21 4 480 380 500 2 12 54 5 575V 525 690 C7 DeviceNet C8 Modbus 09 Type connector D3 RS 232 with D9 connection Notes All 230V drives and 480V drives up to 200 hp IH are only available wi with input option 2 EMC Level N 480V dr with input option 2 575V drives up to 150 ives are available with inpu h input option 1 EMC Level H option 4 EMC Level L 575V hp IH are only available with input option 4 EMC Level L 480V drives up to 30 hp IH are only available with brake chopper option B 480V drives 40 hp IH or N 230V drives up to 15 hp IH are only available with brake chopper option 230V drives 20 hp or No brake chopper able with encl
114. Ethernet based protocol H Max Series 0ption Board Kits Available for Slot B The factory issued relay option board can be replaced with the following option boards to customize the drive for your application needs Option Boards Mounted in Slot B Option Kit Description 1 0 expander card 2 RO and thermistor input Adjustable Frequency Drives Modbus RTU H Max Series provides communication to Modbus RTU RS 485 as a slave on a Modbus network Other communication parameters include an address range from 1 247 a parity of None Odd or Even and the stop bit is 1 The standard board provides 2 Form C RO NO NC and 1 Form A RO NO Option Kit Catalog Number Relay Board 2 H Max Series Option Board Kits Available for Slots D and E The H Max Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of two option boards Option Boards Mounted in Slots D and E The H Max Series factory installed standard board configuration includes an I O board and a relay output board NEMA Type 1 to NEMA Type 12 IP54 Conversion Kit The NEMA Type 12 IP54 option kit is used to convert a NEMA Type 1 to a NEMA Type 12 drive V6 T2 166 Option Kit Option Kit Description Catalog Number 6 x DI DO each digital input can be individually programmed as
115. FI9 FI13 575V FI9 FI14 Keypad 140 140A 730 730A 100 100A 502 502A Alphanumeric 170 170 820 820 125 125 590 590 205 205 920 920 144 144 650 650 245 245 10 10304 170 1704 820 8204 Voltage Rating 300 300 H11 1150A 208 207 920 9204 4 480V 385 385A H13 1300A 261 2614 H10 10304 5 575V 460 460A H16 1600A 325 325 H13 13004 520 520A H19 19404 385 H15 15004 Enclosure Rating 590 590A H23 2300A 460 460A 19 1900A 1 Type 1 IP21 650 6504 0 Chassis Software Series Standard Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 271 2 1 0 Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Product Selection 2 Commen 0 Bus Drive SPA9000 Active Front 480V Products Low Overload AC Current High Overload AC Current Imax Frame A A IH cont min A las A Catalog Number 9 261 287 205 308 349 SPA205A0 4A3N1 H10 460 506 385 578 693 SPA385A0 4A3N1 FI13 1300 1430 1150 1725 2070 SPAH11A0 4A3N1 SPN9000 Non Regenerative Front End 480V Low Overload AC Current High Overload AC Current Imax Frame A limin A min A lo Catalog Number 9 520 572 460 690 828 SPN460A0 4A3N1 5 9000 Inverter Unit 480V
116. Filter Horsepower range Single enclosure for both UL Clean Power Drive features 480V 7 1 2 400 hp drive and filter reduces cUL include at 480V e 230V 7 1 2 100 hp 2 0 508 e UL Type 1 UL 12 UL consult factory for 12 with details su cem U gaskets and filters 575V 15 400 hp dur 22 7 JL Input voltage 480V 230V consult factory for B 9 details drive and filter Complete range of control network and power options Product Identification CFX9000 Drive UL Type 12 40 hp SVX9000 Drive Input Reactor Optional Breaker Disconnect P1 Shunt Fusing Door Mounted Keypad Tuned Shunt Reactor Tuned Harmonic Capacitor Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 195 2 Adjustable Freguency Drives 9000 Drives Catalog Number Selection CFX9000 Enclosed Drives CFX Product Family CFX Integrated filter clean power drive Horsepower Rating Build Alphabetically and Numerically A 007 7 1 2 010 10 hp 015 15 hp 020 20 hp 025 25 hp 030 30 hp hp 040 40 150 150 hp 050 50 200 200 hp 060 60 250 250 hp 075 75 300 300 hp 100 100 350 350 hp 125 125 400 400 hp Enclosure Rating 1 UL Type 1 2 UL Type 12 3
117. Keypad and fieldbus K5 MANUAL AUTO Speed Reference Switch Provides door mounted selector switch for MANUAL AUTO speed reference Control START STOP Pushbuttons Provide door mounted START and STOP pushbuttons for either bypass non bypass configurations Contro KF Bypass Test Switch for RB and RA Allows the user to energize the AF drive for testing while operating the motor on the bypass controller The Test Switch is Addl bypass mounted on the inside of the enclosure door KO Standard Elapsed Time Meter Provides a door mounted elapsed run time meter Control Power On and Fault Power Lights Provide a white Power On light that indicates power to the enclosed cabinet and a red fault light that indicates drive fault Light has occurred 12 Bypass Pilot Lights for RB Bypass Options A green light indicates when the motor is running in Inverter mode and an amber light indicates when the motor is Addl bypass running in Bypass mode The lights are mounted on the enclosure door above the switches LE Red Run Pilot Light 0 87 Inch 22 mm Provides a red Run pilot light that indicates the drive is running Light P1 Input Circuit Breaker High interrupting circuit breaker that provides a means of short circuit protection for the power cables between it and the CPX9000 and Input protection from high level ground faults on the power cable Allows a convenient means of disconnecting the CPX9000 from the line and the operating mechanis
118. N C contact Active FAULT Maximum switching load 250 Vac 6A or 30 Vdc 5A Note Programmable function n lt lt lt 5 5 A 1 2 3 4 10 e gt s o 11 SE sj 5 B8 sg sp Z 9 A y CPU V6 T2 18 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency Drives Dimensions Approximate Dimensions in Inches mm DC1 Sizes FS1 FS3 Degree of Protection 20 0 01 lt 02 Weight Size A A1 B B1 B2 C1 01 02 Ibs kg FS1 3 19 81 0 1 97 50 0 7 24 184 0 6 69 170 0 0 28 7 0 4 88 124 0 0 16 4 0 0 24 6 0 0 47 12 0 2 43 1 1 252 4 21 107 0 2 95 75 0 9 09 231 0 8 46 215 0 0 31 8 0 5 98 152 0 0 20 5 0 0 24 6 0 0 47 12 0 5 73 2 6 253 5 16 131 0 3 94 100 0 10 75 273 0 10 04 255 0 0 33 8 5 6 89 175 0 0 20 5 0 0 24 6 0 0 47 12 0 8 82 4 0 DC1 Sizes FS1 FS3 Degree of Protection IP66 NEMA 4 gt lt 01 I 02 1 c Weight Size A A1 B B1 B2 C1 01 02 Ibs kg FS1 6 34 161 0 5 85 148 5 9 13 232 0 7 44 189 0 0 98 25 0 7 24 184 0 0 14 3 5 0 15 4 0 0 31 8 0 5 51 2 5 252 7 40 188 0 6 93 176 0 10 12 257 0 7 87 200 0 1 12 28 5 7 58 192 0 0 14
119. OPTB1 B1 1 RO NC NO 1 RO NO 1 therm D E OPTB2 B2 1 Al mA isolated 2 AO mA isolated B C D E 0PTB4 4 u u u u u u 1 ext 424 Vdc EXT 24 3 RO NO D E 0 5 B5 1 ext 424 Vdc EXT 24 3 Pt100 B C D E 8 B8 1 RO NO 5 DI 42 240 input B C D E OPTB9 B9 SPI absolute encoder C BB Communication Cards Modbus D E 0 2 cz nm Johnson Controls N2 D E OPTC2 CA PROFIBUS DP D E LonWorks D E OPTC4 C4 m PROFIBUS 09 connector D OPTC5 C5 u u u u u u u CANopen slave D E OPTC6 C6 u u u u u u u DeviceNet D E 7 C7 m m Modbus 09 Type connector D OPTC8 C8 u u u u u u u Modbus TCP D E Cl u u u Adapter SPX only D E OPTD1 D1 Adapter SPX only D E OPTD2 D2 u RS 232 with D9 connection D E OPTD3 D3 9000X Series standard keypad KEYPAD STD 9000X Series remote mount keypad unit OPTRMT keypad not included includes 10 ft cable KIT 9000X keypad holder mounting hardware Notes Analog Input AO Analog Output DI Digital Input DO Digital Output RO Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card V6 T2 256 Vol
120. OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable over Ethernet using a supplied software tool Volume 6 Solid State Motor Control 08100007 2014 www eaton com BACnet Network Communications The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It includes a 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Analog Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 127 EtherNet IP Network Communications The EtherNet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable by Static BOOTP and DHCP methods 2 5 V6 T2 129 2
121. Plates Over Louvers For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B 0 01 E1 F G G1 H J K 19 9 504 29 0 737 16 4 416 18 3 465 27 4 695 25 4 644 4 0 102 3 0 76 Cable Entry Door Clearance CB Handle Shipping Weight L M N P R s T U V w Lbs kg 5 0 127 6 0 152 9 6 245 26 4 669 1 5 38 6 3 160 4 3 108 5 3 134 200 91 V6 T2 88 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 5 9000 Drives 2 4 Approximate Dimensions in Inches mm Size 1 0 1635 2 50 63 5 D 4 Places LIN lt gt wl AA A Fa Y lo A 4 n Y B Mi H B H LLLA lt 0 44 11 2 Mounting 4 NEMA Type 1 IP21 NEMA Type 12 IP54 NEMA Type 12 IP54 Includes Cover Plates Over Louvers Y Y __ Y Z gt lt DD NEMA Type 1 IP21 NEMA Type 12 IP54 with Floor Stand 0 44 11 2 M N F
122. RC 10V AVI 012 013 04 GND gt g 2 g o Relay Sa 38 m 3 lt lt 30 T T 3 80 22 2 5 5 Ol 5 5 o o o 2 S ol ol ols ol 5 E n O 3 3 lt 9 3 o gt 5 o 2 w 3 9 8 28 3 3 5 ai e 9 e 3 5 E B 2 w go S 8 5 2 gt 5 lt e e e e Wire Gauge 22 24 AWG Torque 4 Kgf cm Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 l V6 T2 5 2 Adjustable Freguency Drives 9000 Drives Basic Wiring Diagram R L1 G R L1 SA2 Default Settings 18 Forward Stop s BURN EZ 47 KW 18 R t RE 4 everse Stop 5 5 012 O zi I SN ui sl Rese U MED Multi Step 1 U MED Signal I GND 5 Power for Potentiometer 10V 10 mA Max Master Freq Setting f 1 9 10V 3 Analog Voltage V AVI 0 10 d VR 3K H Analog Current GND 4 20 um O EU RA RC RJ 11 1 EV J 2 GND 3 SG 6831 4 56 RS 485 Communication Port Motor Relay Output Contacts 120
123. REG 12260 920 REG 920 6 0 185 REG 185 6 0 1180 REG 1180 6 0 V6 T2 274 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 0 5 9000 5 9000 5 19000 Common DC Bus Drive Products Options 9000X Series 0ption Board Kits The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes A9 I O board 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard Cards 2 RO B 2 6 DI 1 DO 2 Al 1A0 1 10 ref A 9 2 ext 24 Vdc EXT 24 Extended Cards 2 RO therm B OPTA3 A3 u Encoder low volt 5V 15V24V 4 4 Encoder high volt 15V 24V OPTA5 A5 u Double encoder C OPTA7 7 u m
124. State Motor Control SVX9000 Drives CA08100007E May 2014 www eaton com 2 4 V6 T2 35 2 4 5 9000 Drives SVX9000 Open Drives SVX9000 Open Drives Product Description SVX9000 Series Adjustable Frequency Drives from Eaton s Electrical Sector are the next generation of drives specifically engineered for today s commercial and industrial applications The power unit makes use of the most sophisticated semiconductor technology and a highly modular construction that can be flexibly adapted to the customer s needs The input and output configuration I O is designed with modularity in mind The I O is compromised of option cards each with its own input and output configuration The control module is designed to accept a total of five of these cards The cards contain not only normal analog and digital inputs but also fieldbus cards These drives continue the tradition of robust performance and raise the bar on features and functionality ensuring the best solution at the right price V6 T2 36 Features Volume 6 Solid State Motor Control Robust design proven 500 000 hours MTBF Integrated 396 line reactors standard on drives from through FR9 EMI RFI Filters H standard up to 200 hp 480V 100 hp 230V Simplified operating menu allows for typical programming changes while programming mode provides control of everything Quick Start Wizard built into the program
125. T2 108 for descriptions See Pages V6 T2 106 and V6 T2 107 for complete descriptions Bypass options applicable only in the pump panel three phase design V6 T2 100 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 7 4 5 9000 Drives Product Selection When Ordering Selecta catalog greater than the motor s If dynamic brake Select enclosed options number that meets the full load amp rating The or control communication Add the codes as suffixes application requirements base enclosed package option is desired change to the base catalog number nominal horsepower includes a standard drive the appropriate code in the in alphabetical and numeric voltage and enclosure door mounted local remote base catalog number order rating the enclosed drive s keypad and enclosure e Read all footnotes continuous output amp rating should be equal to or 208V Drives SVX9000Enclosed PUMP Panel Style Three Phase Drives NEMA 12 IP54 Enclosure Frame Base Catalog Frame Base Catalog Size hp Size Number Size Number High Overload Drive and Enclosure A 3 4 4 SVXF0721EP 4 SVXF0731EP SVX00121EP SVX00131EP 2 SVXFIS21EP 00 SVXFI5S31EP 0 2 SVX00221EP SVX00231EP 3 5 SVX00321EP 5 SVX00331EP
126. The 12 pulse arrangement allows the harmonics from the first converter to cancel the harmonics of the second Up to approximately 85 reduction of harmonic current and voltage distortion may six pulse converter This permits a facility to use a larger percentage of AFD loads under IEEE 519 1992 guidelines than allowable using line reactors or DC chokes A harmonic analysis is required to guarantee compliance with guidelines 2 8 provides the phase shift and be achieved over standard Basic 12 Pulse Rectifier with Phase Shifting Transformer 12 Pulse 12 Pulse Diode Inverter Section Phase Shifting Bridge Rectifier Transformer Converter Section 1 aj 12 L3A mi 1 AAA L1B 12 Pulse Bridge Rectifier Converter Section Bus Capacitors Dynamic Braking Transistor Output Transistors IGBT Section 500 hp 480V Drive with 12 Pulse Rectifier 500 hp 480V Drive with 12 Pulse Rectifier 12 Pulse Circuit Current Current harmonics 1000 100 111 4 19 l g 0 06 15 1 25 h3 2 9596 13 0 87 500 l 0 48 7 0 21 lg 0 73 Power 500 hp 0 He 66 2 amps Advantages Disadvantages 500 Moderate cost although Impedance matching of significantly more than phase shifted sources is 21000 r
127. and 690V The drive components are built on the SPX9000 technology V6 T2 268 Volume 6 Solid State Motor Control Front End Units The front end units convert mains AC voltage and current into a DC voltage and current The power is transferred from the mains to a common DC bus and in certain cases vice versa The SPA active front end unit is a bidirectional regenerative power converter for the front end of a common DC bus drive line up An external LCL filter is used at the input This unit is suitable in applications where low mains harmonics are required Contents Description 5 9000 5 9000 5 9000 Common DC Drive Products Application Description Product Comparison Features Standards and Certifications Catalog Number Selection Product Selection Options Technical Data and Specifications Wiring Diagrams Dimensions The SPN non regenerative front end unit is a uni directional motoring power converter for the front end of a common DC bus drive line up The device operates as a diode bridge using diode thyristor components A dedicated external choke is used at the input The unit has the capacity to charge a common DC bus This unit is suitable as a rectifying device when a normal level of harmonics is accepted and no regeneration to the mains is required CA0810000
128. catalog number that meets the application requirements nominal horsepower voltage and enclosure rating The enclosed drive s continuous output amp rating should be equal to or greater than the motor s full load amp rating The base enclosed package includes a standard drive door mounted alphanumeric panel and enclosure Adjustable Frequency Drives CFX9000 product uses the term High Overload in place of the term Constant Torque CT Likewise Low Overload is used in place of the term Variable Torque VT The new terms are a more precise description of the rating The older terms included ambient temperature ratings in addition to overload ratings In order to minimize enclosure size and offer the highest ambient temperature rating overload and temperature ratings are now treated separately Ambient temperature ratings are shown in the following table Volume 6 Solid State Motor Control CFX9000 Drives Ambient Temperature Ratings Enclosure Size I B C 9 40 C 40 C 7 8 50 C 50 C If dynamic brake chopper or control communication option is desired change the appropriate code in the base catalog number All of the programming is exactly the same as the standard SVX9000 drive Select enclosed options Add the codes as suffixes to the base catalog number in alphabetical and numeric order Note For high temperature rating select HT option code and
129. contact factory CA08100007E May 2014 www eaton com 2 7 V6 T2 197 2 9000 Drives 208V Drives 2 9000 Drive Adjustable Freguency Drives UL 1 UL Type 12 UL 12 Filtered Chassis 1 UL Type 12 and NEMA 12 Filtered UL Type 38 hp Current A Frame Base Catalog Number Base Catalog Number Base Catalog Number i Low Overload Drive 7 1 2 24 2 FR5 CFX00721BA CFX00731BA 10 30 8 FR5 CFX01021BA CFX01031BA 15 46 2 FR6 CFX01521BA CFX01531BA 20 59 4 FR6 CFX02021BA CFX02031BA 25 74 8 FR7 CFX02521AA CFX02531AA 30 88 FR7 CFX03021AA CFX03031AA 40 114 FR7 CFX04021AA CFX04031AA 50 143 FR8 CFX05011AA CFX05061AA CFX05031AA 60 169 FR8 CFX06011AA CFX06061AA CFX06031AA 75 211 FR8 CFX07511AA CFX07561AA CFX07531AA 100 273 FR9 CFX10011AA CFX10061AA CFX10031AA High Overload Drive 7 1 2 24 2 FR5 CFX00721EA CFX00731EA 10 30 8 FR6 O CFX01021EA CFX01031EA 15 46 2 FR6 CFX01521EA CFX01531EA 20 59 4 FR7 CFX02021DA CFX02031DA 25 74 8 FR7 CFX02521DA CFX02531DA 30 88 FR7 CFX03021DA CFX03031DA 40 114 FR8 CFX04011DA CFX04061DA CFX04031DA 50 143 FR8 CFX05011DA CFX05061DA CFX05031DA 60 169 FR8 CFX06011DA CFX06061DA CFX06031DA 75 211 FR9 CFX07511DA CFX07561DA CFX07531DA 100 273 FR9 CFX10011DA CFX10061DA CFX10031DA CFX9000 Enclosure
130. display Standard Enclosure space heater Optiona Remote keypad display Standard Oversize enclosure Standard Conventional control elements Standard Output contactor Serial communications Optional Bypass motor starter Optiona 115 Vac control circuit Optional Listings UL cUL Speed setting inputs Protection Features Keypad Standard ncoming line fuses Optiona 0 10 potentiometer voltage signal Standard AC input circuit disconnect Optiona 4 20 mA isolated Configurable Line reactors 3 Standard 4 20 mA differential Configurable Phase rotation insensitive Standard Analog outputs EMI filter Standard Thru Frame 9 Speed frequency Standard nput phase loss protection Standard Torque load current Programmable nput overvoltage protection Standard Motor voltage Programmable Line surge protection Optional Kilowatts Programmable Output short circuit protection Standard 0 10 Vdc signals Configurable w jumpers Output ground fault protection Standard 4 20 mA DC signals Standard Output phase protection Standard Isolated signals Optional Overtemperature protection Standard Discrete outputs DC overvoltage protection Standard Fault alarm Standard Drive overload protection Standard Drive running Standard Motor overload protection Standard Drive at set speed Programmable Programmer software Optional Optional parameters 14 Local remote keypad Standard Dry contacts 1 2 relays Form C Keypad lockout Standard Open collector outputs 1 Fault alarm output Stan
131. fieldbus K5 MANUAL AUTO Speed Reference Switch Provides a door mounted selector switch for MANUAL AUTO speed reference Contro K6 START STOP Pushbuttons Provide door mounted START and STOP pushbuttons for either bypass or non bypass configurations Contro KB 115V Control Transformer 500 VA Provides a fused control power transformer with additional 500 VA at 115V for customer use Control KF Bypass Test Switch for RB and RA Allows the user to energize the AF drive for testing while operating the motor on the bypass controller The test switch is Addl bypass mounted on the inside of the enclosure door KO Standard Elapsed Time Meter Provides a door mounted elapsed run time meter Control POWER ON RUN and FAULT Pilot Lights Provide white POWER ON light that indicates power to the enclosed cabinet a green RUN light that indicates the drive Ligh is running and a red FAULT light that indicates a drive fault has occurred L2 Bypass Pilot Lights for RA and RB Bypass Options A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber Addl bypass MOTOR ON BYPASS light indicates when the motor is running in bypass mode The lights are mounted on the enclosure door above the switches LA Green RUN Light 22 mm Provides a green RUN light that indicates the drive is running Ligh LD Green STOP Light 22 mm Provides a green STOP light that indicates the drive is stopped Ligh LE Red RUN Pilot Lig
132. ideal for panel builders This drive supports single phase motor applications and detachable terminal blocks make control wiring much easier DA1 is the perfect match for demanding OEM applications High performance processor safe torque off multiple fieldbus protocols including SmartWire DT sensorless vector control and the possibility to operate permanent magnet motors are sure to leave a lasting impression V6 T2 8 Volume 6 Solid State Motor Control Models rated at 480 volts three phase 50 60 Hz are available in sizes ranging from 1 to 15 hp Models rated at 240 volts single or three phase 50 60 Hz are available in sizes ranging from 0 5 to 7 5 hp Models rated at 115 volts single phase 50 60 Hz are available in the 0 5 to 3 hp size range Models rated at 575 volts three phase 50 60 Hz are available in sizes ranging from 1 to 20 hp Compact space saving design Rugged and reliable 200 for 4s DA1 or 17596 for 2s DC1 50 C rated DIN rail and screw mountable FS1 and FS2 Side by side installation ndustry leading efficiency delivers energy savings to the customer Integrated filters make the unit suitable for commercial and industrial networks Brake chopper as standard in frames 2 and higher Temperature controlled fan RS 485 Modbus and CANopen as standard Standards and Certifications Product Complies with EN61800 3 2004 EMC At De
133. ii Isc Impedance Source B Total Linear Motor Loads Total Non Linear Drive Loads AMPS AMPS The best way to estimate AFD harmonic contribution to an electrical system is to perform a harmonic analysis based on known system characteristics The one line in this figure would provide the data to complete the calculations Terms PCC Point of Common Coupling is defined as the electrical connecting point between the utility and multiple customers per the specifications in IEEE 519 POA Point of Analysis is defined as where the harmonic calculations are taken An oscilloscope can make all measurements at the PCC or POA to do an on site harmonic evaluation Harmonic Reduction Methods to Meet IEEE 519 1 Line Reactor A line reactor is a three phase series inductance on the line side of an AFD If a line reactor is applied on all AFDs it is possible to meet IEEE guidelines where 10 25 of system loads are AFDs depending on the stiffness of the line and the value of line reactance Line reactors are available in various values of percent impedance most typically 1 1 5 396 and 5 Note The 9000X drives come standard with a nominal 396 input impedance Volume 6 Solid State Motor Control Line Reactor udYYYYX LY YA Y f YYYYA AFD Advantages Low cost Can provide moderate reduction in vo
134. less than 15 dynamic braking is not required because the regenerated energy will be dissipated in the drive and motor losses below and are complete indoor assemblies include a pre wired terminal block and a thermal switch and are not UL Listed 60 seconds Dynamic Brake Resistor Catalog Number Selection DBR R100 0800 t Rated Watts 0800 800 Watts 8000 8000 Watts 080K 80 000 Watis Resistance 100 1 0 Ohms 100 100 Ohms Dynamic Brake Resistor 230V Brake Resistors 20 Duty Cycle 100 Torque Catalog Number Dimensions Inches 50 Duty Cycle 150 Torque Catalog Number Dimensions Inches Drive hp Minimum Ohms 0 75 30 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 2W x 7D x 5H 1 30 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 2W x 7D x 5H 1 5 30 0 DBR R100 W0400 12W x 5D x 5H DBR R036 W1200 2W x 10D x 5H 2 30 0 DBR R100 W0400 12W x 5D x 5H DBR R036 W1200 2W x 10D x 5H 3 30 0 DBR R036 W0800 12W x 7D x 5H DBR R036 W2000 2W x 16D x 5H 4 30 0 DBR R036 W0800 12W x 7D x 5H DBR R030 W2400 9W x 100 x 5H 5 30 0 DBR R036 W0800 12W x 7D x 5H DBR R030 W2800 9W x 13D x 5H 75 20 0 DBR R020 W1200 12W x 10D x5H DBR R020 W4800 26 5W x 13D x 5H 10 10 0 DBR R015 W1600 12W x 13D x5H DBR R112 W6000 26 5W x 13D x 5H 15 10 0 DBR R012 W2400 19W x 10D x5H DBR R010 W9000 28W x 10D x 1
135. ly for input Motor phase supervision Trips if any of the output phases are missing 86 to 149 F 30 to 65 C Max temperature rise during circulation 9 F 59 condensation allowed Unit overtemperature protection Alarm limit 149 F 65 C for heatsink 158 F 70 C for circuit boards 5 System working 87 psi 6 bar limit 158 70 for heatsink 185 F 85 for circuit boards System 580 40 Pressure loss at nominal flow Varies according to size Wiring Diagrams Cooling System Diagrams Example of a Typical Cooling System 30 0 Heat I 35 4 gt D 4 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 259 7 9 Adjustable Freguency Drives LCX9000 Drives Example Pl Diagram of Typical Cooling System and Connections GRZE Cooling Water Inlet O l Frequency pd gt lt 4 Converters I O We 19 Cooling Water Outlet I O M X L Y I Customer Delivery 1 0 Board Diagrams 9 Option Board Control Wiring Basic I O Board A9 10 Vier H 2 E Reference voltage 3 d Al2 a Refere
136. max 10 mA Analog current output 0 4 20 mA 500 kilohms resolution 10 bit accuracy lt 2 Analog voltage output 0 2 10V 21 kilohm resolution 10 bit accuracy lt 2 Relay output max switching voltage 300 Vdc 250 Vac Relay output max switching load 3A 24 Vdc 300 250 Vac continuous load 2A rms Thermistor input 4 7 kohms Note For applications above 3A consult instruction manual CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 8 9000 Drives Wiring Diagrams Power Diagram Up to FR9 Power Diagram Up to FR9 with Bypass Circuit HMCP Breaker Input Inverter Input i Fusing Contactor L Inverter Input Contactor Input Fusing 18 Pulse Transformer 18 Pulse Transformer IT _18 Pulse Optional um Diode Bridge 18 Pulse Reduced Diode Bridge Voltage Starter 9000X Drive 9000X Drive Mechanical Interlock Output ang Bypass Contactor M T Contactor Motor Overload Power Diagram FR10 and Larger Power Diagram FR10 and Larger with Bypass O O Circuit O 9 Inverter Input Contacto
137. otoRx up to 600 ft 1000 V uS DV DT filter Output PH Single overload relay Output PI Dual overload relays Output PN Dual overloads for bypass Addl bypass RA anual HOA bypass controller Bypass RB anual IOB bypass controller Bypass RC Auto transfer HOA bypass controller Bypass RD Auto transfer IOB bypass controller Bypass RG Reduced voltage starter for bypass Bypass S4 Floor stand 6 in Enclosure S5 Floor stand 22 in Enclosure S6 Floor stand 12 in Enclosure S9 Space heater Enclosure Communication Options C2 Modbus C8 Modbus 09 type connector C3 PROFIBUS DP CA Johnson Controls N2 C4 LonWorks Modbus C5 PROFIBUS DP D9 Connector CJ BACnet C6 CANopen Slave CQ EtherNet IP C7 DeviceNet D3 RS 232 with D9 connection Control Options Engineered Options B1 6 DI 1 ext 424 Vdc EXT 24 HT High temperature rating for 50 FR6 optional in all other drives 2 Local remote keypad is included as the standard control panel Some options are voltage and or horsepower specific Consult your Eaton representative for details See Pages V6 T2 206 and V6 T2 207 for complete descriptions Includes local remote speed reference switch See Pages V6 T2 204 and V6 T2 205 for complete descriptions Consult Eaton for availability V6 T2 196 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Product Selection When 0rdering Selecta
138. performance analysis of dynamic events ratings are rated for either applications Equipped with without the need of additional high overload Ih or low high processing power the hardware Simultaneous fast overload indicates SPX9000 can use information monitoring of several drives 11096 overload capacity for from an encoder or a resolver can be done by using the 1 minute out of 10 minutes in order to provide very 9000 tool and CAN ly indicates 150 overload precise motor control communication In capacity for 1 minute out of Sensorless vector and simple applications where reliability 10 minutes frequency control are also and quality are essential for supported Typical high performance the applications requiring high SPX9000 is the logical choice performance are master slave drives positioning applications winder tension control and synchronization The core of the SPX9000 is a fast microprocessor providing high dynamic performance for applications where good motor handling and reliability are required It can be used both in open loop applications as well as in applications requiring encoder feedback Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 119 2 5 5 9000 Drives Features and Benefits Speed error lt 0 01 depending on the encoder ncremental or absolute encoder support Encoder voltages of 5V RS 422 15V or 24V depending on the option c
139. the motor and therefore conserving power This option is used when the distance between a single motor and the drive is 300 600 ft 91 183m This option cannot be used with the brake chopper circuit The output filter option PF should be investigated as an alternative PH Single Overload Relay Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options Itis included with the bypass configurations for overload current protection in the bypass mode The overload relay is mounted within the enclosure and is manually resettable Heater pack included PI Dual Overload Relays This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors The _ Outpu standard configuration includes two bimetallic overload relays each sized to protect a motor with 50 of the drive hp rating For example a 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable Heater packs not included PN Dual Overloads for Bypass This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed Addl bypass for each of the motors The standard configuration includes two bimetallic overload relays each sized to protect a motor with 5096 of the
140. the user is allowed to inject into the utility system increases Notes TDD Total demand distortion is the harmonic current distortion in percent of the maximum demand load current 15 or 30 minute demand ls Maximum short circuit current at the PCC not counting motor contribution Maximum demand load current for all of the connected loads fundamental frequency component at the All of the limits are measured at a point of common coupling V6 T2 223 28 9000 Drives One Line Diagram for Harmonic Analysis Volts Volts Adjustable Frequency Drives Utility Side Transformer Volts kVA Isc Impedance Customer Generator Volts kVA Isc Impedance Total Linear Motor Loads Total Non Linear Drive Loads AMPS Volts Volts Source A 3 PCC Utility Side gt U ms Customer Transformer Volts kVA Isc ma ___ Impedance Motor Generator Set Source AMPS The best way to estimate AFD harmonic contribution to an electrical system is to perform analysis based on known system characteristics The one line in this figure would provide the data to complete the calculations Terms PCC Point of Common Coupling is defined as the electrical connecting point between the utility and multiple customers per the specifications in IEEE 519 POA Point of Analysis is defined as where the h
141. three phase in 22 2 DA1 342D2FB A20C 2 15 460V three phaseout 41 2 DA1 344D1FB A20C 3 22 58 2 DA1 345D8FB A20C 5 4 95 2 DA1 349D5FB A20C 75 55 14 3 DA1 34014FB A20C 10 75 18 3 DA1 34018FB A20C 15 11 24 3 DA1 34024FB A20C 1 05 500 600V three phase in 21 2 DA1 352D1NB A20C 2 45 373V three phaseout 31 2 DA1 353D1NB A20C 3 22 41 2 DA1 354D1NB A20C 5 4 65 2 DA1 356D5NB A20C 75 55 9 2 DA1 359D0NB A20C 10 75 12 3 DA1 35012NB A20C 15 11 17 3 DA1 35017NB A20C 20 15 22 3 DA1 35022NB A20C Notes These are constant torque high overload rated drives For all applications select the unit such that the motor current is less than or equal to the rated continuous output current Brake chopper circuit available as standard in frames 2 and 3 V6 T2 12 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency AC Drives IP66 DA1 Series IP66 Enclosure Drives 9 100 Continuous Frame hp kW Volts Current In A Size 9 Catalog Number 1 0 75 200 240V single phase in 43 2 DA1 124D3FB A6SC 2 15 7 2 1 12700 65 3 22 105 2 DA1 12011FB A6SC 1 075 200 240V three phase in 43 2 DA1 324D3FB A6SC 2 15 7 2 DA1 327D0FB A6SC IP66S 3 22 105 2 DA1 32011FB A6SC 5 4 18 3 DA1 32018FB A6SC 1 075 380 480V three phase in 22 2 DA1 342D2FB A6SC 2 1
142. to DC The inverter section uses 5 to convert DC power to a simulated AC sine wave that can vary in frequency from 0 400 Hz The six pulse VFD drive creates harmonic current distortion The harmonic current that is created is energy that can not be used by customers and causes external heat and losses to all components including other drives that are on the same power distribution The figure is a 100 hp drive with 45A of damaging harmonic current 100 hp Six Diode Rectifier Design Current Amps 1000 500 500 1000 0 100 0 10625 0 1125 0 11875 0 125 Time Seconds 100 hp Six Pulse Nonproductive Harmonic Current Current Amps 1000 500 500 1000 0 100 0 10625 0 1125 0 11875 0 125 Time Seconds Six Pulse Nonproductive Harmonic Current Six Pulse Circuit Current harmonics l 100 lj 6 10 19 1 77 5 22 596 lg 4 06 Ing 1 12 9 3896 17 2 26 Ins 0 86 Power 100 hp Harmonic current 45 amps V6 T2 190 Volume 6 Solid State Motor Control Adjustable Frequency Drives Guidelines of Meeting IEEE Std 519 1992 Harmonic Distortion Limits The IEEE 519 1992 Specification is a standard that provides guidelines for commercial and industrial users that are implementing medium and low voltage equipment Maximum Harmonic Current Distortion in of the Fu
143. w HOA K2 disconnect switch P2 See Freestanding Option selection on Page V6 T2 134 FR10 FR14 includes 3 line reactor but it is not integral to chassis V6 T2 126 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 5 9000 Drives 2 5 Accessories Demo Drive and Power Supply Demo Drive and Power Supply Catalog Number 9000XDEMO Description 9000X demo drive NEMA 12 IP54 Conversion Kit The NEMA Type 12 1 54 kit option is used to convert a NEMA Type 1 IP21 to a NEMA Type 12 IP54 drive The NEMA Type 12 IP54 NEMA Type 12 IP54 Conversion Kit Approximate Dimensions in Inches mm kit consists of a metal drive shroud fan kit for some frames adaptor plate and plugs Approximate Frame Size Delivery Code Length Width Height Weight Lb kg Catalog Number FRA W 13 330 7 178 4 102 4 1 8 OPTN12FR4 FR5 16 406 8 203 7 178 5 2 3 OPTN12FR5 FR6 21 533 10 254 5 127 7 3 2 OPTN12FR6 Flange Kits Flange Kit NEMA Type 12 IP54 Flange kits for NEMA Type Flange Kit NEMA Type 12 The flange kit is utilized when the power section is mounted through the back panel of an enclosure Includes flange mount brackets and NEMA Type 12 IP54 fan components Metal shroud not included Note 12 IP54 enclosure drive rating are determined by rating of drive Flange Kit NEMA Type 12 IP54 Frames 4 5 and 6 Fra
144. with a door mounted IOB selector switch For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked RC Auto Transfer HOA Bypass Controller The manual HAND OFF AUTO HOA 3 contactor bypass option provides a means of bypassing the SVX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of the load to across the line operation after a drive trip This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in either mode For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked D
145. 0 0325 5 ANV 1 FR10 0520 4 ANV FR10 0385 5 ANV 1 FR10 0416 5 ANV Driver board 1 S00450 S00450 Driver adapter board 1 VB00330 VB00330 Shunt board 6 VB00497 VB00510 6 VB00498 VB00511 6 VB00537 VB00545 Covers Top cover 1 FR10340 FR10340 Side cover 2 FR10341 FR10341 DC section Balancing resistor 2 PP13027 PP13028 DC busbars kit right 1 0000005 0000005 Bus capacitor 12 00335 00336 Inverter Rectifier module 1 FR10823 FR10823 Charging resistor 1 00066 00066 Diode 3 01177 01177 Rectifier board 1 00591 00592 Keypad D SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 1 FR10846 FR10846 Fan assembly right 1 FR10847 FR10847 Fan AC 2 01080 01080 Fan fuse 4 PP20202 PP20202 Starting cap 2 S00528 S00528 Fan driver board AC 2 VB00299 VB00299 solation transformer left 1 FR10844 FR10844 solation transformer right 1 FR10845 FR10845 Main DC fan DC fan 2 PP00072 00072 DC power supply 2 01017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 139 Adjustable Freguency Drives 5 9000 Drives 2 5 FR11 Spare Parts Quantity 230V 480V 575V Categor
146. 0 4A2N1 FR11 400 520 500 590 SPX400A0 4A2N1 500 590 650 SPX500A0 4A2N1 650 600 730 SPX550A0 4A2N1 FR12 600 730 820 SPX600A0 4A2N1 820 700 920 SPX650A0 4A2N1 700 920 800 1030 SPX700A0 4A2N1 FR13 800 1030 900 1150 SPX800A0 4A2N1 900 1150 1000 1300 SPX900A0 4A2N1 1000 1300 1200 1450 SPXH10A0 4A2N1 FR14 1200 1600 1500 1770 SPXH12A0 4A2N1 1600 1940 1800 2150 SPXH16A0 4A2N1 1900 2300 2200 2700 SPXH19A0 4A2N1 575V SVX9000 Drives 525 690V NEMA Type 1 IP21 Drives Frame Size hp ly Current ly hp 14 Current I Catalog Number FR6 2 3 3 3 4 5 SVX002A1 5A4N1 3 4 5 5 5 SVX003A1 5A4N1 5 5 5 7 5 SVX004A1 5A4N1 5 7 5 7 1 2 10 SVX005A1 5A4N1 7 1 2 10 10 13 5 SVX007A1 5A4N1 10 13 5 15 18 SVX010A1 5A4N1 15 18 20 22 SVX015A1 5A4N1 20 22 25 27 SVX020A1 5A4N1 25 27 30 34 SVX025A1 5A4N1 FR7 30 34 40 41 SVX030A1 5A4N1 40 41 50 52 SVX040A1 5A4N1 FR8 50 52 60 62 SVX050A1 5A4N1 60 62 75 80 SVX060A1 5A4N1 75 80 100 100 SVX075A1 5A4N1 FR9 100 100 125 125 SVX100A1 5A4N1 125 125 150 144 SVX125A1 5A4N1 150 144 170 SVX150A1 5A4N1 170 200 208 SVX175A1 5A4N1 Note V6 T2 40 FR10 FR14 includes 3 line reactor but it is not integral to chassis Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 SVX9000 Drives SVX9000 Open Drives 525 690V 12 I
147. 0 90 9 35 0 75 15 75 13 62 98 0 44 45 230 15 20 11450 10231 6 35 1178 6 101 6 276 9 327 5 19 1 400 0 346 0 480 25 40 FS7 208 25 30 58 32 56 30 0 25 59 46 5 00 13 98 12 35 0 75 15 50 13 55 165 0 74 84 230 25 30 1481 3 14300 6 35 1510 3 127 0 355 1 313 7 19 1 393 7 244 2 480 50 75 Note C distance is spacing required to mount multiple drives V6 T2 184 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 6 H Max Series Drives Approximate Dimensions in Inches mm Enclosure Box A NEMA Type 3R 0 44 11 2 Mounting Holes 4 Places Approx Approx Voltage hp Weight Shipping Weight AC I H H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs kg Lbs kg Three Phase 208V 1 10 33 00 31 36 29 67 25 35 21 05 16 97 15 30 2 07 17 24 16 26 3 31 170 77 215 98 20V 1000 838 2 796 5 753 6 643 9 534 7 429 8 388 6 52 6 437 9 413 0 84 1 480V 1 20 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 185 2 6 Adjustable Freguency Drives Series Drives Approximate Dimensions Inches mm Enclosure Box B NEMA Type 3R 2 w 0 44 11 2 Mounting Holes 4 Places Approx Approx Voltage hp Weight Shipping Weight AC I H H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs kg Lbs kg Three Phase 208V 15 46 09 44 45 42 77 36 35 26 31 20
148. 0 SPX400A1 4A4N1 500 590 550 650 SPX500A1 4A4N1 550 650 600 730 SPX550A1 4A4N1 Note Integrated fuses as standard Limited option selection available 115V transformer KB light kit L1 4 speed potentiometer w HOA K2 Disconnect switch P2 See Freestanding Option selection Page V6 T2 134 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 123 2 5 Adjustable Frequency Drives SPX9000 Drives SPX9000 Open Drives 380 500V Type 12 IP54 Drives Frame EE Size hp ly Current ly hp Ij Current Catalog Number Q e FRA 1 22 14 2 33 SPX001A2 4A1B1 eu 14 2 33 2 43 SPXF15A2 4A1B1 2 43 3 56 SPX002A2 4A1B1 3 56 5 76 SPX003A2 4A1B1 5 76 9 SPX005A2 4A1B1 9 7 1 2 12 SPX006A2 4A1B1 FR5 7 1 2 12 10 16 SPX007A2 4A1B1 10 16 15 23 SPX010A2 4A1B1 15 23 20 31 SPX015A2 4A1B1 FRG 20 31 25 38 SPX020A2 4A1B1 25 38 30 46 SPX025A2 4A1B1 30 46 40 61 SPX030A2 4A1B1 FRZ 40 61 50 72 SPX040A2 4A1N1 50 72 60 87 SPX050A2 4A1N1 60 87 75 105 SPX060A2 4A1N1 FRE 75 105 100 140 SPX075A2 4A2N1 100 140 125 170 SPX100A2 4A1N1 125 170 150 205 SPX125A2 4A1N1 FR9 150 205 200 261 SPX150A2 4A1N1 200 245 250 300 SPX200A2 4A1N1 380 500V NEMA Type 12 1P54 Freestanding Drives Frame Size hp 14 Current ly hp lj Current I Catalog Number FR10 250 330 300 385 SPX250A2 4A4N1 300 385 350 460 SPX3
149. 00 Hz DC brake at start and stop Acceleration time 0 1 to 600 seconds Programmable V Hz curve Deceleration time 0 1 to 600 seconds Adjustable switching frequency Brake Resistor Minimum Values Autorestart function after fault 230V Series FS2 and FS3 47 ohms Protections and supervisions 400V Series FS2 100 ohms FS3 47 ohms Power section fault indication Ambient Conditions External fault Ambient operating 14 F 10 C no frost to 122 F 50 C Rated loadability ly temperature P20 NEMA 0 Fieldbus communication Storage temperature 40 F 40 C to 140 F 60 C Second deceleration time AD EEE Relative humidity 0 to 95 RH noncondensing non corrosive no dripping water Analog input range selection signal scaling and filtering Enclosure class P20 FS1 FS3 controller Notes Skip frequencies Exception 115V single phase in 230V three phase out Only FS2 and 253 drives are equipped with brake chopper circuit Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 15 2 2 Adjustable Frequency Drives PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Standards DC1 Series 0 Specifications Reliability e Digital DI1 DI4 are Includes Pretested components programmable Four inputs two digital and Computerized testing Digital relay and analog two digital analog Final test with full load outputs are progr
150. 000000 CSBS0000000000 Standard slot A 1 0 card 1 OPTA9 OPTA9 Standard slot 1 0 card 1 2 2 Power board 1 VB00308 0004 2 VB00208 0003 5 1 VB00308 0007 2 VB00208 0004 5 1 VB00308 0008 2 VB00208 0005 5 1 VB00208 0007 5 1 VB00208 0009 5 1 VB00410 0012 5 ARV Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main fan DC fan main 1 PP01060 PP01060 Other Mounting kit fixing kit 1 FR00040 FR00040 Mounting kit fixing kit N12 1 FR00079 FR00079 Control cover plastic N1 1 FR00006 FR00006 FR5 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 PP01088 01088 Control module SVX control module 1 CSBS0000000000 CSBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 Converter Power board 1 VB00313 0017 2 VB00213 0016 5 1 VB00313 0025 2 VB00213 0022 5 1 VB00313 0031 2 VB00213 0031 5 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main fan DC fan main 1 PP01061 PP01061 Other Mounting kit fixing kit 1 FR00050 FR00050 Mounting kit fixing kit N12 O 1 FR00081 FR00081 Control cover plastic N1 1 FR05011 FRO5011 Notes Only for NEMA Type 12 IP54 Type drives Factory recommended parts Select one part number
151. 00A2 4A4N1 350 460 400 520 SPX350A2 4A4N1 380 500V Open Chassis Drives Frame Size hp ly Current ly hp Ij Current Catalog Number FR10 250 330 300 385 SPX250A0 4A2N1 300 385 460 SPX300A0 4A2N1 350 460 400 520 SPX350A0 4A2N1 FR11 400 520 500 590 SPX400A0 4A2N1 500 590 650 SPX500A0 4A2N1 650 600 730 SPX550A0 4A2N1 FR12 600 730 820 SPX600A0 4A2N1 820 700 920 SPX650A0 4A2N1 700 920 800 1030 SPX700A0 4A2N1 FR13 800 1030 900 1150 SPX800A0 4A2N1 900 1150 1000 1300 SPX900A0 4A2N1 1000 1300 1200 1450 SPXH10A0 4A2N1 FR14 1200 1600 1500 1770 SPXH12A0 4A2N1 1600 1940 1800 2150 SPXH16A0 4A2N1 Notes ntegrated fuses as standard Limited option selection available 115V transformer KB light kit L1 HOA K4 speed potentiometer w HOA K2 disconnect switch P2 See Freestanding Option selection on Page V6 T2 134 FR10 FR14 includes 3 line reactor but it is not integral to chassis V6 T2 124 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives 575V Drives 9000 Open Drives 525 690 Type 1 1 21 Drives Frame Size hp ly Current ly hp lj Current I Catalog Number e T u FR6 2 3 3 3 4 5 SPX002A1 5A4N1 o 7 3 45 5 5 SPX003A1 5A4N1 5 5 5 75 SPX004A1 5A4N1
152. 011AA SVX04021AA 3 50 8 SVX05011AA 8 SVX05021AA 4 60 170 8 SVX06011AA 8 SVX06021AA 5 759 205 8 SVX07511AA 8 SVX07521AA 100 261 9 SVX10011AA 9 SVX10021AA Notes CA08100007E May 2014 www eaton com Select enclosed options Add the codes as suffixes to the base catalog number in alphabetical and numeric order Read all footnotes Adjustable Freguency Drives 2 4 SVX9000 Drives 230V Drives SVX3000 Enclosed __ Base Drives Drives NEMA Type 1 1 21 NEMA Type 12 IP54 Enclosure Frame Base Catalog Frame Base Catalog Size hp Current A Size Number Size Number High Overload Drive and Enclosure 0 3 4 3 7 4 SVXF0712EA 4 SVXF0722EA SVX00112EA SVX00122EA 00 1 1 2 6 6 SVXF1512EA SVXF1522EA 2 7 8 SVX00212EA SVX00222EA 3 1 SVX00312EA SVX00322EA 5 17 5 5 SVX00512EA 5 SVX00522EA 7 1 2 25 SVX00712EA SVX00722EA 1 10 31 6 SVX01012EA 6 SVX01022EA 15 48 SVX01512EA SVX01522EA 2 20 61 7 SVX02012DA 7 SVX02022DA 25 75 SVX02512DA SVX02522DA 30 88 SVX03012DA SVX03022DA 3 40 114 8 SVX04012DA 8 SVX04022DA 4 50 140 8 SVX05012DA 8 SVX05022DA 5 60 170 8 SVX06012DA 8 SVX06022DA 75 205 9 SVX07512DA 9 SVX07522DA 100 261 SVX10012DA SVX10022DA Low Overload Drive and Enclosure 0 1 48 4 SVX00112BA 4 SVX00122BA 14 2 6 6 SVXF1512BA SVXF1522BA 2 78 SVX00212BA SVX00222BA 3 11 SVX00312BA SVX00322BA 5 17 5 5 SVX00512BA 5 SVX00522BA 7 1 2 25 SVX00712BA SVX00722BA 10
153. 02 Emissions EMC level dependent Connection to power Once per minute or less typical operation Short circuit withstand rating 65 kAIC combination Output Ratings Output voltage 0 to V Uj line voltage in Continuous output current Ambient temperature max 104 F 40 overload 1 1 xl 1 min 10 min Overload current 110 1 min 10 min Initial output current 150 for two seconds Output frequency 0 to 320 Hz Frequency resolution 0 01 Hz Control Characteristics Control method Frequency control V f open loop sensorless vector control Switching frequency 1 310 amps adjustable with parameter 2 6 9 FS4 FS7 default 6 kHz Frequency reference Analog input Resolution 0 1 10 bit accuracy 1 Panel reference Resolution 0 01 Hz Field weakening point 8 to 320 Hz Acceleration time 0 1 to 3000 seconds Deceleration time 0 1 to 3000 seconds Braking torque DC brake 30 x Tp Ambient Conditions Ambient operating temperature FS4 FS7 14 F 10 C no frost 1049 40 C Drive can operate at 122 F 50 C Storage temperature 40 to 158 F 40 to 70 Relative humidity 0 to 95 RH noncondensing non corrosive no dripping water 2 EN61800 3 2004 Category C2 Delivered with Class C2 EMC filtering as default Control Connections
154. 02565DA 30 34 FR7 CPX03065DA 40 41 FR7 CPX04065DA 50 52 FR8 CPX05065DA 60 62 FR8 CPX06065DA 75 80 FR8 CPX07565DA 8 100 100 FRO CPX10065DA 125 125 FRO CPX12565DA 150 144 FRO CPX15065DA 9 200 208 FR10 CPX20065DA 250 261 FR10 CPX25065DA 300 325 FR10 CPX30065DA 10 400 385 FR11 40065 450 460 FR11 CPX45065DA 500 502 FR11 CPX50065DA 11 600 590 FR12 CPX60065DA 650 650 FR12 CPX65065DA 700 750 FR12 CPX70065DA Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as guideline Drives should be sized per motor nameplate The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 235 2 8 Adjustable Frequency Drives CPX9000 Drives 9000 Drive _ CPX9000 Base Drive Type Enclosure Current Chassis Base Catalog Size hp 9 A Frame Number Low Overload Drive 7 25 27 FR6 CPX02535AA 30 34 FR6 03035 40 41 FR7 CPX04035AA 50 52 FR7 CPX05035AA 60 62 FR8 CPX06035AA 75 80 FR8 CPX07535AA 100 100 FR8 CPX10035AA 8 125 125 FR9 12535 150 144 FR9 15035 200 208 FR9 CPX20035AA High Overload Drive 7 25 27 FR6 CPX02535DA 30 34 FR7 CPX03035DA 40 41 FR7 CPX04035DA 50 52 FR8 CPX05035DA 60 62 FR8 CPX06035DA 75 80 FR8 CPX07535DA 8 100 100 FRO CPX10035DA
155. 03034EP 40 SVX04024DP SVX04034DP 50 SVX05024DP SVX05034DP 60 SVX06024DP SVX06034DP C 75 8 SVX07524DP 8 SVX07534DP 100 SVX10024DP SVX10034DP 125 SVX12524DP SVX12534DP 150 9 9 SVX15034DP 200 SVX20034DP 250 10 10 SVX25034DP 300 SVX30034DP 350 SVX35034DP 400 119 11 SVX40034DP 500 SVX50034DP Low Overload Drive and Enclosure A 1 1 2 4 SVXF1524BP 4 SVXF1534BP 2 SVX00224BP SVX00234BP 3 SVX00324BP SVX00334BP 5 SVX00524BP SVX00534BP 7 1 2 SVX00724BP SVX00734BP 10 5 SVX01024BP 5 SVX01034BP 15 SVX01524BP SVX01534BP 20 SVX02024BP SVX02034BP 25 6 SVX02524BP 6 SVX02534BP 30 SVX03024BP SVX03034BP B 40 7 SVX04024BP 7 SVX04034BP 50 SVX05024AP SVX05034AP 60 SVX06024AP SVX06034AP 75 SVX07524AP SVX07534AP 100 8 10024 8 10034 125 12524 12534 150 15024 15034 200 9 9 SVX20034AP 250 SVX25034AP 300 10 10 SVX30034AP 350 SVX35034AP 400 SVX40034AP 500 119 1 SVX50034AP 600 SVX60034AP Notes Enclosure dimensions starting on Page V6 T2 112 Includes drive local remote keypad and enclosure FR11 has limited power options available V6 T2 104 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives 480V Drives continued SVX9000 Enclosed Pump Panel Style Single Phase Drives NEMA 12 IP54 NEMA Type 3R Enclosure Frame Base Catalog F
156. 06024DA 3 75 105 8 SVX07514DA 8 SVX07524DA 100 140 SVX10014DA SVX10024DA 4 125 170 8 SVX12514DA 8 SVX12524DA 5 150 205 9 SVX15014DA 9 SVX15024DA 200 245 SVX20014DA SVX20024DA 6 899 250 300 0 SVX25014DA 10 SVX25064DA 300 385 SVX30014DA SVX30064DA 350 460 SVX35014DA SVX35064DA 8 900 400 520 1 SVX40014DA 11 SVX40064DA 500 590 SVX50014DA SVX50064DA 550 650 SVX55014DA SVX55064DA 600 730 2 SVX60014DA 12 SVX60064DA 650 820 SVX65014DA SVX65064DA 700 920 SVX70014DA SVX70064DA Notes brake chopper options see Page V6 T2 46 See enclosure dimensions starting on Page V6 T2 88 Includes drive local remote keypad and enclosure The smaller enclosure Size 6 accommodates only power options input disconnect P1 and input line fuses P3 Bypass and other options require Size 8 Adding any standard control option will not require the larger enclosure For other options consult factory The smaller enclosure Size 8 accommodates only power options input disconnect P1 and input line fuses P3 Bypass and other options require Size 9 Adding any standard control option will not require the larger enclosure Consult factory V6 T2 80 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives SVX9000Enclosei __ Base Drives continued Drives NEMA Type 1 1P21 NEMA Type 12 IP54 Enclosure Frame Base Catalog Fram
157. 075A1 2A1N1 100 261 125 300 SVX100A1 2A1N1 208 240V NEMA Type 12 1 54 Drives Frame Size hp ly Current ly hp 1 Current I Catalog Number FR4 3 4 3 7 1 4 8 SVXF07A2 2A1B1 1 4 8 1 1 2 6 6 SVX001A2 2A1B1 1 1 2 6 6 2 7 8 SVXF15A2 2A1B1 2 7 8 3 11 SVX002A2 2A1B1 3 11 12 5 SVX003A2 2A1B1 FR5 12 5 5 17 5 SVX004A2 2A1B1 5 17 5 74 2 25 SVX005A2 2A1B1 7 1 2 25 10 31 SVX007A2 2A1B1 FR6 10 31 15 48 SVX010A2 2A1B1 15 48 20 61 SVX015A2 2A1B1 FR7 20 61 25 75 SVX020A2 2A1N1 25 75 30 88 SVX025A2 2A1N1 30 88 40 114 SVX030A2 2A1N1 FR8 40 114 50 140 SVX040A2 2A1N1 50 140 60 170 SVX050A2 2A1N1 60 170 75 205 SVX060A2 2A1N1 FR9 75 205 100 261 SVX075A2 2A1N1 100 261 125 300 SVX100A2 2A1N1 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives 480V SVX9000 Drives SVX9000 Open Drives 380 500V NEMA Type 1 IP21 Drives Frame Size hp ly Current ly hp 14 Current I Catalog Number gt T a FR4 1 2 2 1 1 2 3 3 SVX001A1 4A1B1 e 2 1 1 2 33 2 43 SVXFI5A1 4A1B1 2 43 3 5 6 SVX002A1 4A1B1 3 5 6 5 7 6 SVX003A1 4A1B1 5 76 9 SVX005A1 4A1B1 9 7 1 2 12 SVX006A1 4A1B1 FR5 7 1 2 12 10 16 SVX007A1 4A1B1 10 16 15 23 SVX010A1 4A1B1 15 23 20 31 SVX015A1 4A1B1 FR6 20 31 25 38 SVX020A1 4A1B1 25 38 30 46 SVX025A1 4A1B1 30 46 40 61 SVX03
158. 0A1 4A1B1 FRZ 40 61 50 72 SVX040A1 4A1N1 50 72 60 87 SVX050A1 4A1N1 60 87 75 105 SVX060A1 4A1N1 FR8 75 105 100 140 SVX075A1 4A1N1 100 140 125 170 SVX100A1 4A1N1 125 170 150 205 SVX125A1 4A1N1 FR9 150 205 200 261 SVX150A1 4A1N1 200 245 250 300 SVX200A1 4A1N1 380 500 NEMA 12 1 54 Drives Frame Size hp ly Current 14 hp Ij Current ly Catalog Number FRA 1 22 1 1 2 33 SVX001A2 4A1B1 1 1 2 33 2 43 SVXF15A2 4A1B1 2 43 3 5 6 SVX002A2 4A1B1 3 5 6 5 7 6 SVX003A2 4A1B1 5 7 6 9 SVX005A2 4A1B1 9 7 1 2 12 SVX006A2 4A1B1 FR5 74 2 12 10 16 SVX007A2 4A1B1 10 16 15 23 SVX010A2 4A1B1 15 23 20 31 SVX015A2 4A1B1 FR6 20 31 25 38 SVX020A2 4A1B1 25 38 30 46 SVX025A2 4A1B1 30 46 40 61 SVX030A2 4A1B1 FRZ 40 61 50 72 SVX040A2 4A1N1 50 72 60 87 SVX050A2 4A1N1 60 87 75 105 SVX060A2 4A1N1 FR8 75 105 100 140 SVX075A2 4A1N1 100 140 125 170 SVX100A2 4A1N1 125 170 150 205 SVX125A2 4A1N1 FR9 150 205 200 261 SVX150A2 4A1N1 200 245 250 300 SVX200A2 4A1N1 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 39 2 4 Adjustable Freguency Drives 5 9000 Drives 380 500V Open Chassis Drives SVX9000 Open Drives Frame Size hp 1 Current ly hp Ij Current Catalog Number cza T FR10 250 330 300 385 SPX250A0 4A2N1 2 300 385 350 460 SPX300A0 4A2N1 350 460 400 520 SPX350A
159. 0H 20 33 DBR R9D3 W3200 19W x 10D x5H DBR R3D4 W012K 28W x 10D x 10H 25 3 3 DBR R5D5 W4000 26 5W x 10D x 5 DBR R5D1 W015K 28W x 16D x 10H 30 33 DBR R4D8 W4800 26 5W x 10D x 5 DBR R4D1 W020K 28W x 16D x 10H 40 14 DBR R004 W6000 26 5W x 13D x 5H DBR R3D4 W025K 30W x 18D x 16H 50 14 DBR R3D1 W7500 26 5W x 16D x 5H DBR R2D1 W030K 30W x 18D x 24H 60 14 DBR R2D8 W9000 26 5W x 16D x 5H DBR R002 W036K 30W x 18D x 24H 75 14 DBR R2D6 W012K 28W x 10D x 10H DBR R1D5 W045K 30W x 18D x 32H 100 14 DBR R002 W015K 28W x 16D x 10H DBR R1D4 W060K 30W x 18D x 40H Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 5 V6 T2 131 2 5 Adjustable Freguency Drives 5 9000 Drives 480V Brake Resistors Drive hp Minimum 20 Duty Cycle 100 Torque 50 Duty Cycle 150 Torque Ohms Catalog Number Dimensions Inches Catalog Number Dimensions Inches 1 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 12W x 7D x 5H 1 5 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 2 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 3 63 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2000 12W x 16D x 5H 5 63 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2800 19W x 13D x 5H 6 63 0 DBR R100 W1200 12W x 10D x 5H DBR R070 W4000 19W x 16D x5H 75 63 0 DBR R100 W1200 12W x 10D x5H DBR R063 W4800 26 5W x 13D
160. 0X Series RS 232 cable 13 ft 00104 Notes Analog Input AO Analog Output DI Digital Input DO Digital Output RO Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 275 2 10 Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Technical Data and Specifications SPA9000 SPN9000 SPI9000 Description Specification Supply Connection Input voltage Uj AC front end modules 380 500 525 690 10 to 10 Input voltage U DC inverter 465 800 Vdc 640 1100 Vdc 0 to 0 the waviness of the inverter supply voltage formed in rectification of the electric network s alternating voltage in basic frequency must be less than 50V peak to peak Output voltage AC inverter 3 0 U 1 4 Output voltage DC active front end module 10 10 x 1 35 x Uj factory default Output voltage DC non regenerative front end module 1 35 x Uin Ambient Conditions Ambient operating temperature 14 no frost to 122 F 10 to 50 C lh 14 frost to 104 F 10 to 40 C Ir Storage temperature 40 to 158 F 40 to 70 C Relative humidity 0 to 95 RH non condensing non corrosive no dripping wate
161. 1 and NEMA Type 12 IP54 FR8 E H1 gt lt H2 1 WI W2 E y_ E R2 R1 gt SE E I I I I I Cs 7 01 iii 9 O SE TP Y Weight Voltage ly 01 H1 H2 H3 wi w2 R1 Dia R2Dia Lbs kg 230V 40 60 13 5 344 30 1 764 28 8 732 2841721 11 5 291 10 255 0 7 18 0 4 9 127 58 480 75 125 575V 50 75 V6 T2 62 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 5 9000 Drives Approximate Dimensions in Inches mm Type 1 1 21 and Type 12 IP54 with Flange Kit FR7 and FR8 gt H6 H4 gt H4 gt lt H5 gt Dia 1 ji e lt H2 gt lt H1 lt w3 gt gt lt lt H7 lt W1 gt m im 6 i o 5 01 L O ESA V lt H3 gt H12 lt gt i lt H9 gt lt H9 oh H10 gt lt gt 11 o o o o I 1i
162. 1 gis AH 9D6 9 6A 3 hp B IntelliDi P3 Fused drive isolation _ ntelliDisconnect 12 C IntelliDisconnect NEMA Type EE Output contactor 022 22 7 5 hp SA Space heater w transformer only 028 28A 10 hp 042 42A 15 hp 2 ka AS IntelliPass Bypass Options 080 80A 30 hp Pilot lights Power ON RUN Fault Bypass P3 Fused drive isolation can not be used with P6 or MI P6 Third contactor drive isolation cannot be used with P3 IS or MI M1 Manual bypass includes isolation contactor and pilot lights not available with P3 L4 P6 or IS SA Space heater w transformer Type 3R only 9 Auxiliary contacts 1 Isolation switch cannot be used with P6 or MI Standard Onboard Communications RS 485 Communications BACnet MS TP Master slave token protocol Universal BACnet RS 485 Modbus RTU RS 485 ASCII or RTU remote terminal unit 32 nodes N2 Johnson Controls Metasys N2 network Onboard Ethernet Based Communications port left side of keypad BACnet IP Ethernet industrial protocol Modbus TCP Transmission control protocol Ethernet based Notes IntelliPass two contactor electronic bypass standard All boards are varnished Corrosion resistant Battery included in all drives for real time clock Three year lifetime Keypad kit includes HOA bypass EMI RFI filters included DC link choke included V6 T
163. 10 Reference voltage Output 10V Maximum load 10 mA Reference potential 6 Analog Input 1 Frequency reference value Analog 0 to 10V R gt 72 0 4 20 mA R 500 0 Can be switched with parameter P2 30 DI4 Digital Input 5 Frequency reference value Digital 8 30V high 7 0 Reference potential connection terminal 9 8 A01 Analog Output 1 Output frequency Analog 0 to 10V maximum 20 mA Can be switched with parameter P2 11 D01 Digital Output 1 Output frequency Digital 8 24V 9 OV Reference potential QV connection terminal 7 10 04 Digital Input 4 Fixed frequency 2 Analog 0 to 10V gt 72 0 4 20 mA R 500 0 switched with parameter 2 30 AD Analog Input 2 Fixed frequency FF2 Digital 8 30V high 1 A02 Analog output 2 Output current Analog 0 to 10V maximum 4 20 mA Can be switched with parameter P2 11 002 Digital output 2 Output current Digital 8 24V 2 STO Safe Torque mE Enable 424V 3 STO Safe Torque Off Enable 0V 4 K11 Relay 1 changeover contact Active FAULT Maximum switching load 250 Vac 6A or 30 Vdc 5A 5 K14 Relay 1 changeover contact N O Active FAULT O Maximum switching load 250 Vac 6A or 30 Vdc 5A 6 K12 Relay 1 changeover contact N C Active FAULT O Maximum switching load 250 Vac 6A or 30 Vdc 5A 7 K23 Relay 2 N O contact Active FAULT Maximum switching load 250 Vac 6A or 30 Vdc 5A 8 K24 Relay 2
164. 100007E May 2014 www eaton com Exception 115V single phase in 230V three phase out Only three phase FS2 and FS3 drives are equipped with brake chopper circuit V6 T2 27 2 3 Adjustable Freguency Drives Series Adjustable Freguency Drives Standards 1 0 Specifications e Digital DI1 DI6 are Includes freely programmable The Six digital inputs user can assign multiple Two analog inputs functions to a single input 4 20 mA Digital relay and analog Q 10V outputs are freely programmable One analog output One digital output Two relay outputs e RS 485 interface M Max I O Interface Reliability Pretested components Computerized testing Final test with full load Conformal coated boards Eaton s Electrical Services amp Systems national network of AF drive specialists Terminal Signal Factory Preset Description 1 10V Ref output voltage Maximum load 10 mA 2 Analog signal in 1 Freq reference P 0 10 Ri 200k ohms min 3 GND 0 signal ground 6 24V 24V output for Dis 20 max load 50 mA 7 GND 0 signal ground 8 D Digital input 1 Start forward P 0 30V Ri 12k ohms min 9 012 Digital input 2 Start reverse P 10 013 Digital input 3 Preset speed AUTOGEN A A RS 485 signal FB communication Ref B
165. 1032 2x9 4 2 x 239 21 7 552 441 200 FI13 40 6 1032 27 9 708 21 8 553 674 306 FI14 40 6 1032 2 27 9 2 x 708 21 8 553 1348 612 Non Regenerative Front Ends FI9 40 6 1030 9 4 239 14 6 372 148 67 Inverter Units FR4 11 5 292 5 0 128 7 5 190 11 5 FR6 20 4 519 7 7 195 9 3 237 35 16 FR7 23 3 591 9 3 237 10 1 257 64 29 FR8 29 8 758 11 4 289 13 5 344 106 48 F9 40 6 1030 9 4 239 14 6 372 148 67 FI10 40 6 1032 9 4 239 21 7 552 220 100 FI12 40 6 1032 2x9 4 2 x 239 21 7 552 441 200 FI13 40 6 1032 27 9 708 21 8 553 674 306 FI14 40 6 1032 2x21 9 2 x 708 21 8 553 1348 612 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 279
166. 10K 30W x 18D x 64H 250 2 5 DBR R2D5 W036K 30W x 18D x 24H DBR R003 W140K 30W x 180 x 72H 300 25 DBR R3D3 W045K 30W x 18D x 32H 400 17 DBR R002 W060K 30W x 18D x 48H 3 450 1 7 DBR R1D8 W070K 30W x 18D x 48H 2 500 13 DBR R002 WO080K 30W x 18D x 56H Note Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 5 V6 T2 133 2 5 Adjustable Frequency Drives SPX9000 Drives Control Communication Options Available Control Communications Options Option Description Option Type K2 Door Mounted Speed Potentiometer with HOA Selector Switch Provides the SPX9000 with the ability to start stop and adjust the speed reference from Control door mounted control devices or remotely from customer supplied inputs In HAND position the drive will start and the speed is controlled by the door mounted speed potentiometer The drive will be disabled in the OFF position When AUTO is selected the drive run and speed control commands are via user supplied dry contact and 4 20 mA signal K4 HAND OFF AUTO Switch for Non Bypass Configurations Provides a three position selector switch that allows the user to select either a HAND or AUTO Control mode of operation HAND mode is defaulted to keypad operation and AUTO mode is defaulted to control from an external terminal source These modes of operation be configured via programming to allow for alternate combinations of start and sp
167. 2 172 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 6 H Max Series Drives Product Selection H Max Series IntelliPass NEMA 1 Two Contactor Bypass Standard 208 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 6 HMX4D631NA 2 75 HMX7D531NA 3 10 6 01131 5 5 16 7 01731 75 24 2 02531 10 30 8 HMX03131NA 6 15 46 2 HMX04731NA 20 59 4 HMX06031NA 7 25 74 9 HMX07531NA 30 88 HMX08831NA 230 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 2 HMX4D232NA 2 6 8 HMX6D832NA 3 9 6 90632 5 5 15 2 HMX01632NA 75 22 HMX02232NA 10 28 HMX02832NA 6 15 42 HMX04232NA 20 54 HMX05432NA 7 25 68 HMX06832NA 30 80 HMX08032NA 480 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 2 1 HMX2D134NA 2 3 4 HMX3D434NA 3 5 6 HMX5D634NA 5 7 6 HMX7D634NA 75 11 HMX01134NA 5 10 14 HMX01434NA 15 21 HMX02134NA 20 27 HMX02734NA 6 25 34 HMX03434NA 30 40 HMX04034NA 40 52 HMX05234NA 7 50 65 HMX06534NA 60 77 HMX07734NA 75 96 HMX09634NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for specifics Enclosure size and weight differ from NEMA 1 and 12 products Volu
168. 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Enclosure Box 0 44 11 2 Mounting Holes 4 Places 5 w gt 4 Places lt gt D wa 0 y Tl i 1 rw e im 2 s o 2 e Os ba e H1H2 H2 H3 H H3 H5 H4 5 y NN A lt W2 L lt W1 gt ke lt D1 gt w3 D2 LA in E D1 DD s e 7 BULL Approx Voltage hp hp Weight AC lu I H H1 H2 H3 H4 H5 w W1 W2 W3 D D1 D2 Lbs kg Three Phase 208 30 50 40 60 58 09 56 45 54 77 48 35 78 09 77 64 37 73 30 92 29 30 3 34 17 74 16 77 3 31 230 30 1475 5 1433 8 1391 2 1228 1 1983 5 1972 1 9583 7854 7442 848 450 6 426 0 84 1 50 40 60 480 75 125 100 150 Single Phase 230V 25 40 58 09 56 45 54 77 48 35 78 09 77 64 37 73 30 92 29 30 3 34 17 74 16 77 3 31 480V 40 60 1475 5 1433 8 1391 2 1228 1 19835 19721 958 3 785 4 7442 84 8 450 6 426 0 841 Note Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 117 2 4 Adjustable Freguency Drives SVX9000 Drives Ap
169. 21 173 2018 340 19 32 660 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 91 2 4 5 9000 Drives Approximate Dimensions Inches mm NEMA Type 1 1 21 NEMA Type 12 IP54 NEMA Type 12 1 54 Includes Cover Plates Over Louvers Adjustable Frequency Drives Size 4 0 50 12 7 Lifting Eyes i 2 Places m K 9 i _ 4 M P I I gt g INI p V For Cable Entry y L E sf A F t H Top View B RR 0 44 11 2 8008 3 Mounting Holes For Cable 5 R mem fa F fi NE O Lo Es EIL NE PE PEI Bottom View For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 26 4 671 90 0 2286 19 4 493 19 5 495 3 3 83 23 0 584 1 5 38 11 7 298 5 5 140 0 9 24 89 4 2270 4 0 102 3 0 76 Cable Entry Door Clearance Handle Shipping Weight L M N P R s T U V w RR ss TT UU Lbs kg 53 23 4 13 8 1 0 11 2 26 4 1 5 8 0 4 8 9 5 08 1 3 825 375 133 594 351 25 286 669 38 204 121 2349 19 32 V6 T2 92 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives Approximate Dimensions in Inches mm
170. 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 2 00451 00451 ASIC board 2 00457 00457 Star coupler 1 00593 00593 Control ASIC fan 2 01096 01096 Control module SVX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot B 1 0 card 1 2 2 Converter Power module 1 FR12 0820 4 ANV FR12 0650 5 ANV 1 FR12 0920 4 ANV FR12 0750 5 ANV 1 FR12 1030 4 ANV FR12 0820 5 ANV Driver board 2 S00450 S00450 Driver adapter board 2 VB00330 VB00330 Shunt board 12 VB00498 VB00511 Covers Top cover 2 FR10340 FR10340 Side cover 4 FR10341 FR10341 DC section Balancing resistor 4 PP13027 PP13027 DC busbars kit right 0000005 0000005 Bus capacitor 24 00335 00336 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad D SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 2 FR10846 FR10846 Fan assembly right 2 FR10847 FR10847 Fan AC 4 01080 01080 Fan fuse 8 PP20202 PP20202 Starting 4 S00528 S00528 Fan driver board AC 4 VB00299 VB00299 solation transformer left 2 FR10844 FR10844 solation transformer right 2 FR10845 FR10845 Main DC fan DC fan 4 00072 00072 DC power supply 4 01017 01017 No
171. 3 MMX NET XA Communication adapter kit FS4 and FS5 MMX NET XA 45 PROFIBUS DP network card with serial connection XMX NET PS A PROFIBUS DP network card with Sub D connection XMX NET PD A DeviceNet network card XMX NET DN A Remote Keypad 9 Description Catalog Number Keypad bezelandcable Ua OPTRMT BP HMAX Remote copy paste keypad MMX REMKEY TEXT VFD adapter MMX ADAPTER RJ45 Notes NEMA Type 1 kit provides conduit entry plate Additional input and output reactors are available Consult Eaton representative for a complete listing All three components are required for remote keypad operation V6 T2 26 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 3 M Max Series Adjustable Frequency AC Drives Technical Data and Specifications Ratings M Max Basic Controller 20 Standard Ratings Description Specification Protections Specifications M Max Series Drives Description Specification Input Ratings Overcurrent protection Trip limit 4 0 x lu instantaneously Input voltage Vin 10 15 115 230V series 437 400V series 874 Vdc 575V series 1048 Vdc trip level 115 230V series 183 400V series 333 Vdc 575V series 460 Vdc trip level Overvoltage protection Undervoltage protection Ground fault protection Ground fault is tested before every start In case of ground fault in motor or motor cable
172. 30 x Tp Ambient Conditions A 5 alog input voltage 10V R 200 kohms differential Resolution 0 1 Accuracy 1 DIP switch selection voltage current Analog input current 0 4 to 20 mA 250 ohms differential Digital inputs 6 Positive or negative logic 18 to 30 Vdc Auxiliary voltage 24V 10 max 250 mA Output reference voltage 10V 3 max load 10 mA Analog output 0 10V 0 4 to 20 mA max 500 ohms Resolution 10 bit Accuracy 2 DIP switch selection voltage current Relay outputs 3 programmable 2 Form C 1 Form A relay outputs Switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Hard wire jumper Between terminal 6 and 10 factory default DIP switch setting default RS 485 off A01 current A12 current A11 voltage Protections Overcurrent protection Yes Overvoltage protection Yes DC bus regulation anti trip Yes accelerates or decelerates the load Undervoltage protection Yes Earth fault protection Yes in case of earth fault in motor or motor cable only the frequency converter is protected nput phase supervision Yes trips if any of the input phases are missing otor phase supervision Yes trips if any of the output phases are missing Ambient operating FS4 FS9 14 F 10 no frost to 104 F 40 C Overtemperature protecti
173. 358 261 392 470 SPI261A0 5A3N1 385 424 325 488 585 SPI325A0 5A3N1 12 460 506 385 578 693 SPI385A0 5A3N1 502 552 460 690 828 SPI460A0 5A3N1 590 649 502 753 904 SPI502A0 5A3N1 650 715 590 885 1062 SPI590A0 5A3N1 750 825 650 975 1170 SPI650A0 5A3N1 13 920 1012 820 1230 1476 SPI820A0 5A3N1 1030 1133 920 1380 1656 SPI920A0 5A3N1 1180 1298 1030 1464 1755 SPIH10A0 5A3N1 F114 1500 1650 1300 1950 2340 SPIH13A0 5A3N1 1900 2090 1500 2250 2700 SPIH15A0 5A3N1 2250 2475 1900 2782 3335 SPIH19A0 5A3N1 Note For filter and line reactor information see Page V6 T2 274 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 273 2 1 0 Adjustable Frequency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products LCL Filters Line Reactor P Line Reactor for LCL Filters for Active Front End 480 Non Regenerative Amps Catalog Number Amps Catalog Number Front 480 575VV 10 REG 1050 270 REG 27050 Watts Catalog Amps Losses Number 18 REG 1850 410 REG 41050 2 32 REG 3250 580 58050 an T E 48 REG 4850 840 REG 8405 0 75 REG 7550 1160 REG 11605 0 110 REG 1105 0 1480 REG 1480 5 0 180 REG 180 5 0 LCL Filters for Active Front End 690V Amps Catalog Number Amps Catalog Number 14 REG 146 0 287 REG 287 6 0 23 REG 236 0 390 REG 390 6 0 35 REG 35 6 0 460 REG 460 6 0 52 REG 526 0 620 REG 620 6 0 85 REG 85 6 0 780 REG 780 6 0 122
174. 40 to 60 C Humidity maximum non condensing 95 Altitude 100 load capacity derating up to 3280 ft 1000m 1 derating for each 328 ft 100m above 3280 ft 1000m max 9842 ft 3000m Line voltage variation 10 15 Line freguency variation 45 66 Hz Efficiency gt 96 Power factor displacement 0 99 V6 T2 210 Volume 6 Solid State Motor Control 10 bit accuracy lt 2 Relay output max switching voltage 300 Vdc 250 Vac Relay output max switching load 34 24 300 Vdc 250 Vac Relay output max continuous load 2A rms Thermistor input 4 7 kohms Notes Units FR10 rated 40 For applications above consult instruction manual CA08100007E May 2014 www eaton com Wiring Diagram Control Input Output Reference potentiometer 1 10 kohms AS Adjustable Freguency Drives 2 pe Remote reference 0 4 20 mA Paa A 22 READY CFX9000 Drives Basic Application Default I O Configuration Terminal Signal Description OPTA9 1 10Vref Reference output Voltage for potentiometer etc AIT Analog input voltage range 0 10 Voltage input frequency reference 3 Al 1 0 Ground Ground for reference and controls 4 Al2 Analog input current range 0 20
175. 400 CH63 LCX590A0 5A3N2 650 591 433 450 CH63 LCX650A0 5A3N2 750 682 500 500 CH63 LCX750A0 5A3N2 820 745 547 560 CH74 LCX820A0 5A3N2 920 836 613 650 CH74 LCX920A0 5A3N2 1030 936 687 700 CH74 LCXH10A0 5A3N2 1180 1073 787 800 CH74 LCXH11A0 5A3N2 1300 1182 867 900 CH74 LCXH13A0 5A3N2 1500 1364 1000 1000 CH74 LCXH15A0 5A3N2 540 675 Vdc Liquid Cooled Inverter Units Drive Output Current Motor Output Power Power Loss Thermal Rated Cont Rated Cont Optimum Motor Optimum Motor c a T ly A 1 A ly A at ly 400V kW at ly 500V kW kW Chassis Catalog Number 16 15 11 75 11 0 4 0 2 0 6 CH3 LCX016A0 4A7B2 22 20 15 11 15 0 5 0 2 0 7 CH3 LCX022A0 4A7B2 31 28 71 15 18 5 0 7 0 2 0 9 CH3 LCX031A0 4A7B2 38 35 25 18 5 22 0 8 0 2 1 0 CH3 LCX038A0 4A7B2 45 4 30 22 30 1 0 0 3 1 3 CH3 LCX045A0 4A7B2 61 55 4 30 37 1 3 0 3 1 5 CH3 LCX061A0 4A7B2 72 65 48 37 45 1 2 0 3 1 5 CH4 LCX072A0 4A7N2 87 79 58 45 55 1 5 0 3 1 8 CH4 LCX087A0 4A7N2 105 95 70 55 75 1 8 0 3 2 1 CH4 LCX105A0 4A7N2 140 127 93 75 90 2 3 0 3 2 6 CH4 LCX140A0 4A7N2 168 153 112 90 110 2 5 0 3 2 8 CH5 LCX168A0 4A7N2 205 186 137 110 132 3 0 0 4 3 4 CH5 LCX205A0 4A7N2 261 237 174 132 160 4 0 0 4 4 4 CH5 LCX261A0 4A7N2 300 273 200 160 200 4 5 0 4 4 9 CH61 LCX300A0 4A7N2 385 350 257 200 250 5 5 0 5 6 0 CH61 LCX385A0 4A7N2 460 418 307 250 315 5 5 0 5 6 0 CH62 LCX460A0 4A7N2 520 473 347 250 355 6 5 0 5 7 0 CH62 LCX520A0 4A7N2 590 536 393 315 400 7 5 0 6 8 1 CH62 LCX590A0 4A7N2 V6 T2 254 Volum
176. 46 Fan assembly right 2 FR10847 FR10847 Fan AC 4 01080 01080 Fan fuse 8 PP20202 PP20202 Starting 4 S00528 S00528 Fan driver board AC 4 VB00299 VB00299 solation transformer left 2 FR10844 FR10844 solation transformer right 2 FR10845 FR10845 Main DC fan DC fan 4 00072 00072 DC power supply 4 01017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 5 V6 T2 141 2 D Adjustable Frequency Drives SPX9000 Drives FR13 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control ASIC board 1 00457 00457 ASIC assembly 1 60501030 60501030 Control ASIC fan 1 PP01096 PP01096 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 Converter Power module 2 3 FI13 1150 4 ANV FR13 1030 5 ANV 3 FI13 1300 4 ANV FR13 1180 5 ANV 3 FI13 1450 4 ANV FR13 920 5 ANV Driver board 3 00454 00454 Driver adapter board 2 VB00330 VB00330 Shunt board 18 VB00505 00516 18 VB00514 VB0051
177. 4V C OPTAE AE 2 DO pulse direction SPX only 6 DI 1 ext 24 Vdc EXT 24 B C D E OPTB1 B1 1 1 RO NO 1 therm B C D E 0 2 B2 1 Al mA isolated 2 AO mA isolated D E 0PTB4 B4 1 ext 24 Vdc EXT 24 3 RO NO C D E 5 5 1 ext 24 Vdc EXT 24 3 Pt100 0 8 B8 1 RO NO 5 DI 42 240 Vac input C D E 9 9 Communication Cards Modbus D E 0 2 cz u u u u u u u Johnson Controls N2 D E OPTC2 CA Modbus TCP D E u BACnet D E CJ EtherNet IP DE OPTCQ ca u PROFIBUS DP D E LonWorks D E OPTC4 C4 m PROFIBUS DP 09 connector DE OPTC5 C5 u u u u u u u CANopen slave DE OPTC6 C6 u DeviceNet D E OPTC7 C7 Modbus 09 type DE OPTC8 C8 u u Adapter SPX only D E OPTD1 D1 u u Adapter SPX only BE OPTD2 D2 u RS 232 with 09 connection D E OPTD3 D3 m Notes Analog Input AO Analog Output DI Digital Input DO Digital Output Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card 5 9000 drives only FR10 and larger Volume 6 Solid State Moto
178. 5 10 63 0 DBR R063 W1600 12W x 13D 5 DBR R063 W6000 26 5W x 16D x 5H 15 42 0 DBR R042 W2400 19W x 10D x5H DBR R042 W9000 28W x 10D x 10H 20 21 0 DBR R030 W3200 19W x 13D x5H DBR R023 W012K 28W x 13D x 10H 25 21 0 DBR R030 W4000 19W x 16D x5H DBR R021 W015K 28W x 13D x 10H 30 14 0 DBR R020 W4800 26 5W x 13D x 5H DBR R014 WO020K 30W x 18D x 24H 40 6 5 DBR R112 W6000 26 5W x 13D 5 DBR R007 W025K 30W x 18D x 16H 50 6 5 DBR R013 W7500 26 5W x 16D x 5H DBR R8D5 W030K 30W x 18D x 24H 60 6 5 DBR R010 W9000 28W x 10D x 10H DBR R7D3 W036K 30W x 18D x 24H 75 3 3 DBR R009 W012K 28W x 13D x 10H DBR R3D3 W045K 30W x 18D x 32H 100 3 3 DBR R5D1 W015K 28W x 16D x 10H DBR R004 WO60K 30W x 18D x 40H 125 33 DBR R4D1 W020K 28W x 16D x 10H DBR R004 W070K 30W x 18D x 48H 150 3 3 DBR R3D4 W025K 30W x 18D x 16H DBR R3D5 WO085K 30W x 18D x 56H 200 33 DBR R3D3 W030K 30W x 18D x 24H DBR R3D3 W110K 30W x 18D x 72H 250 1 4 DBR R2D5 W036K 30W x 18D x 24H 300 1 4 DBR R1D5 W045K 30W x 18D x 32H O 350 14 DBR R1D4 WO060K 30W x 18D x 40H O 400 0 9 DBR R1D4 WO060K 30W x 18D x 40H 500 0 9 DBR R0D9 W080K 30W x 18D x 48H 550 0 9 DBR R001 W085K 30W x 18D x 56H Note Consult factory V6 T2 132 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 575 Brake Resistors 20 100 Torgue Drive hp Minimum Ohms Catalog Number Dimensions Inches Adjustable Frequency Driv
179. 5 261 310 61A 40 hp 30 kW 72 50 hp 37 kW 87A 60 hp 45 kW 105A 75 hp 55 kW 140 100 hp 75 kW 170A 125 hp 90 kW 205 150 hp 110 kW 261 200 hp 132 kW 3104 250 hp 160 kW HMK 3 4 A 304 2 1 N E Product Braking Application HMX HVAC drive N No brake chopper low overload Phase 3 Three phase Enclosure 1 Open 1 21 2 Open 12 IP54 Voltage 2 200 240V 4 380 480 Input Options Frame and Voltage Specific 2 C2 Software Series A Z Keypad G Graphical panel Amperes 200 240 Volts 380 480 Volts 307 3 7 0 75 hp 0 55 kW 062 62A 20 hp 15 kW 304 3 4 1 5 hp 1 1 kW 046 46 30 hp 22 kW Notes All boards are varnished conformed coated Corrosion resistant Battery included in all drives for real time clock Keypad kit includes bypass Keypad kit includes back reset for Europe application EMI RFI filters included DC link choke included Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 163 2 6 Adjustable Freguency Drives Series Drives Product Selection Series Drives 230 Vac NEMATypet NEMA Type 1 IP21 ra FS Drive Output Current Assigned Motor Ratings 4 Frame Low Overload Full Drive kW 230 Vac Low Overload Full Catalog Size Load Amps
180. 5 460V hice phase au 41 2 DA1 344D1FB A6SC 3 22 58 2 DA1 345D8FB A6SC 5 4 95 2 DA1 349D5FB A6SC 75 55 14 3 DA1 34014FB AGSC 10 75 18 3 DA1 34018FB AGSC 1 075 500 600V three phase in 21 2 DA1 352D1NB A6SC 2 45 SS PIPI out 31 2 DA1 353D1NB A6SC 3 22 41 2 DA1 354D1NB A6SC 5 4 65 2 DA1 356D5NB A6SC 75 55 9 2 DA1 359D0NB A6SC 10 75 12 3 DA1 35012NB A6SC 15 11 17 3 DA1 35017NB A6SC Notes These are constant torque high overload rated drives For all applications select the unit such that the motor current is less than or equal to the rated continuous output current Brake chopper circuit available as standard in frames 2 and 3 Non disconnect version available Substitute with A66C Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 13 2 2 Adjustable Frequency Drives PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Accessories DC1 and DAT Series PC Communication Kit and Copy Paste Module Remote Keypad Description Catalog Number Description Catalog Number BT communication stick DX COM STICK LED remote keypad 7 segment display IP54 rated DX KEY LED USB PC connection kit DX COM PCKIT OLED remote keypad full text display multi line text DX KEY OLED Optional Communication Modules Description DeviceNet plug in interface module Catalog Number DX NET DEVICENET PROFIBUS DP plug in interface module DX NET PROFIBUS EtherNet IP plug in interfa
181. 5 MMX11AA3D7N0 0 1 1 2 48 165 FS3 MMX11AA4D8N0 0 1 4 200 240V single phase in 17 42 FS1 MMX12AA1D7F0 0 1 2 Ze toe phase out 24 57 MMX12AA2D4F0 0 3 4 28 66 MMX12AA2D8F0 0 1 37 83 FS2 MMX12AA3D7F0 0 1 1 2 48 112 MMX12AA4D8F0 0 2 7 141 MMX12AA7D0F0 0 3 96 158 FS3 MMX12AA9D6F0 0 1 4 200 240V three phase in 17 27 FS1 MMX32AA1D7N0 0 1 2 230V thae phase ut 24 35 MMX32AA2D4N0 0 3 4 28 38 MMX32AA2D8N0 0 1 37 43 52 MMX32AA3D7N0 0 1 1 2 48 68 MMX32AA4D8N0 0 2 7 84 MMX32AA7DONO 0 3 11 134 FS3 MMX32AA011N0 0 5 17 17 FSA MMX32AA017F0 0 7 1 2 25 25 MMX32AA025F0 0 10 31 31 FS5 MMX32AA031F0 0 15 38 38 MMX32AA038F0 0 1 2 380 480 three phase in 13 22 FS1 MMX34AA1D3F0 0 3 4 19 28 MMX34AA1D9F0 0 1 24 32 MMX34AA2DAFO 0 1 1 2 33 4 FS2 MMX34AA3D3F0 0 2 43 56 MMX34AA4D3F0 0 3 56 73 MMX34AA5D6F0 0 4 76 96 FS3 MMX34AA7D6F0 0 5 9 115 MMX34AASDOFO 0 7 1 2 12 149 MMX34AA012F0 0 10 14 187 MMX34AA014F0 0 10 16 16 FS4 MMX34AA016F0 0 15 23 23 MMX34AA023F0 0 20 31 31 FS5 MMX34AA031F0 0 25 38 38 0 1 575V three phase in 1 7 2 0 FS3 MMX35AA1D7N0 0 2 SSV three phase out 27 36 20710 0 3 39 50 MMX35AA3D9N0 0 5 6 1 76 MMX35AA6D1N0 0 7 1 2 90 104 MMX35AA9DONO 0 Notes Horsepower ratings based on the use of a 240V 460V and 575V NEMA four or six pole squirrel cage induction motor and are for reference only Units are to be selected such that t
182. 5 SVX00521EP 0 SVX00531EP 0 7 2 SVX00721EP 0 SVXO0731EP 10 6 SVX01021EP 6 SVX01031EP 15 SVXO1521EP 0 SVX01531EP 0 B 20 7 SVX02021DP 7 SVX02031DP 25 SVX02521DP SVX02531DP 30 SVX03021DP SVX03031DP C 40 8 SVX04021DP 8 SVX04031DP 50 SVX05021DP SVX05031DP 60 SVX06021DP SVX060310P F 75 9 9 SVX07531DP 100 7 SVX100310P Low Overload Drive and Enclosure 1 4 SVX00121BP 4 SVX00131BP MP SVXFI521BP 0 SVXFI531BP 2 SVX00221BP SVX00231BP 4 SVX00321BP 0 SVX00331BP 0 5 5 SVX00521BP 5 SVX00531BP 7 2 SVX00721BP SVX00731BP 10 SVX01021BP SVX01031BP 0 15 6 SVX01521BP 6 SVX01531BP 20 SVX02021BP SVX02031BP B 25 7 SVX02521AP 7 SVX02531AP 30 SVX03021AP SVX03031AP 40 SVX04021AP SVX04031AP C 50 8 SVX05021AP 8 SVX05031AP 60 SVX06021AP 0 SVX06031AP 0 75 SVXO7521AP 0 SVXO7531AP F 100 9 9 SVX10031AP 125 _ SVX12531AP Notes Enclosure dimensions starting on Page V6 T2 112 Includes drive local remote keypad and enclosure Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 101 2 4 Adjustable Freguency Drives 5 9000 Drives 230V Drives SVX9000Enclosed PUMP Panel Style Three Phase 2 Drives NEMA Type 12 IP54 Type Enclosure Frame Base Catalog Frame Base Catalog Size hp Siz
183. 5014DA 200 245 FR9 CPX20014DA 9 250 300 FR10 CPX25014DA 300 385 FR10 CPX30014DA 350 460 FR10 CPX35014DA 10 400 520 FR11 CPX40014DA 500 590 FR11 CPX50014DA 550 650 FR11 CPX55014DA 11 600 720 FR12 CPX60014DA 650 820 FR12 CPX65014DA 700 840 FR12 CPX70014DA Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 231 2 8 Adjustable Frequency Drives CPX9000 Drives CPx9000 Drive CPX9000 Base Drive NEMA 12 Filtered Enclosure Current Chassis Base Catalog Size hp 2 A Frame Number Low Overload Drive 7 25 38 FR6 CPX02564BA 30 46 FR6 CPX03064BA 40 61 FR6 CPX04064BA 50 72 FR7 CPX05064AA 60 87 FR7 CPX06064AA 75 105 FR7 CPX07564AA 100 140 FR8 CPX10064AA 125 170 FR8 CPX12564AA 150 205 FR8 CPX15064AA 8 200 261 FR9 CPX20064AA 250 300 FR9 CPX25064AA 9 300 385 FR10 CPX30064AA 350 460 FR10 CPX35064AA 400 520 FR10 CPX40064AA 10 500 590 FR11 CPX50064AA 550 650 FR11 CPX55064AA 600 730 FR11 CPX60064AA 11 650 820 FR11 CPX65064AA 700 920 FR12 CPX70064AA 800 1030 FR12 CPX80064AA High Overload Drive 7 25 38 FR6 CPX02
184. 564EA 30 46 FR6 CPX03064EA 40 61 FR7 CPX04064DA 50 72 FR7 CPX05064DA 60 87 FR7 CPX06064DA 75 105 FR8 CPX07564DA 100 140 FR8 CPX10064DA 125 170 FR8 CPX12564DA 8 150 205 FR9 CPX15064DA 200 245 FR9 CPX20064DA 9 250 300 FR10 CPX25064DA 300 385 FR10 CPX30064DA 350 460 FR10 CPX35014DA 10 400 520 FR11 CPX40064DA 500 590 FR11 CPX50064DA 550 650 FR11 CPX55064DA 11 600 720 FR12 CPX60064DA 650 820 FR12 CPX65064DA 700 840 FR12 CPX70064DA Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA G The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure V6 T2 232 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Frequency Drives 2 8 9000 Drives GPX9000 Drive 9000 Base Drive Type Enclosure Current Chassis Base Catalog Size hp A Frame Number Low Overload Drive 7 25 38 FR6 CPX02534AA 30 46 FR6 CPX03034AA 40 61 FR6 CPX04034AA 50 72 FR7 CPX05034AA 60 87 FR7 CPX06034AA 75 105 FR7 CPX07534AA 100 140 FR8 CPX10034AA 125 170 FR8 CPX12534AA 150 205 FR8 CPX15034AA 8 200 261 FR9 CPX20034AA 250 300 FR9 CPX25034AA High Overload Drive 7 25 38 FR6 CPX02534DA 30 46 FR6 CPX03034DA 40 61 FR7 CPX04034DA 50 72 FR7 CPX05034DA 60 87 FR7 CPX06034DA 75 105 FR
185. 5V Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products 2 10 Low Overload AC Current High Overload AC Current Imax Frame li conc A limin A IH cont min A 15 A Catalog Number 9 144 158 125 188 713 SPA125A0 5A3N1 F110 385 424 325 488 585 SPA325A0 5A3N1 F113 1030 1133 920 1380 1656 SPA920A0 5A3N1 SPN9000 Non Regenerative Front End 575V Low Overload AC Current High Overload AC Current Imax Frame li conc A limin A IH cont min A la A Catalog Number 9 600 660 510 732 888 SPN510A0 5A3N1 SPI9000 Inverter Unit 575V Low Overload AC Current High Overload AC Current Imax Frame 1 A limin A limin A lo A Catalog Number FR6 45 5 32 5 6 4 SPI003A1 5A3N1 5 5 6 4 5 7 9 SPI004A1 5A3N1 7 5 8 5 5 8 11 SPI005A1 5A3N1 10 11 7 5 11 15 SPI007A1 5A3N1 13 5 15 10 15 20 SPI010A1 5A3N1 18 20 13 5 20 2 SPI013A1 5A3N1 22 24 18 2 36 SPI018A1 5A3N1 2 30 22 33 44 SPI022A1 5A3N1 34 37 27 41 54 SP1027A1 5A3N1 FR7 41 45 34 51 68 SPI034A1 5A3N1 52 57 41 62 82 SPI041A1 5A3N1 FR8 62 68 52 78 104 SPI052A0 5A3N1 80 88 62 93 124 SPI062A0 5A3N1 100 110 80 120 160 SPI080A0 5A3N1 9 125 138 100 150 200 SPI100A0 5A3N1 144 158 125 188 213 SPI125A0 5A3N1 170 187 144 216 245 SPI144A0 5A3N1 208 229 170 255 289 SPI170A0 5A3N1 261 287 208 312 375 SPI208A0 5A3N1 325
186. 61 25 75 SPX020A2 2A1N1 25 75 30 88 SPX025A2 2A1N1 30 88 40 114 SPX030A2 2A1N1 FR8 40 114 50 140 SPX040A2 2A1N1 50 140 60 170 SPX050A2 2A1N1 60 170 75 205 SPX060A2 2A1N1 FR9 75 205 100 261 SPX075A2 2A1N1 100 261 SPX100A2 2A1N1 V6 T2 122 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives 480V Drives SPX9000 Open Drives 380 500V NEMA Type 1 IP21 Drives Frame Size hp ly Current ly hp lj Current I Catalog Number e T u 1 22 1 1 2 33 SPX001A1 4A1B1 ev uy 2 1472 33 2 43 SPXFI5A1 4A1B1 N 2 4 3 3 5 6 SPX002A1 4A1B1 3 5 6 5 7 6 SPX003A1 4A1B1 5 7 6 9 SPX005A1 4A1B1 9 7 1 2 12 SPX006A1 4A1B1 FR5 74 2 12 10 16 SPX007A1 4A1B1 10 16 15 23 SPX010A1 4A1B1 15 23 20 31 SPX015A1 4A1B1 FR6 20 31 25 38 SPX020A1 4A1B1 25 38 30 46 SPX025A1 4A1B1 30 46 40 61 SPX030A1 4A1B1 FR7 40 61 50 32 SPX040A1 4A1N1 50 32 60 87 SPX050A1 4A1N1 60 87 75 105 SPX060A1 4A1N1 FR8 75 105 100 140 SPX075A1 4A1N1 100 140 125 170 SPX100A1 4A1N1 125 170 150 205 SPX125A1 4A1N1 FR9 150 205 200 261 SPX150A1 4A1N1 200 245 250 300 SPX200A1 4A1N1 380 500V NEMA Type 1 IP21 Freestanding Drives Frame Size hp lp Current ly hp Ij Current ly Catalog Number FR10 250 330 300 385 SPX250A1 4A4N1 300 385 350 460 SPX300A1 4A4N1 350 460 400 520 SPX350A1 4A4N1 FR11 400 520 500 59
187. 7 18 VB00541 VB00547 Covers Top cover 3 FI10001 FI10001 Side cover 3 FI10003 FI10003 DC section Balancing resistor 6 PP13034 PP13034 Bus capacitor 36 00335 00336 DC busbars kit 3 113329 113329 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 3 FI13301 FI13301 Fan AC 3 01080 01080 Fan fuse 6 PP20202 PP20202 Starting 3 S00520 S00520 Fan driver board AC 3 VB00299 VB00299 Isolation transformer 3 PP10057 PP10057 Main DC fan DC fan 4 00072 00072 DC power supply 4 01017 01017 Notes Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 142 Volume 6 Solid State Motor Control 08100007 2014 www eaton com 14 Spare Parts Adjustable Frequency Drives SPX9000 Drives Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control ASIC board 2 00457 00457 Star coupler 1 00593 00593 ASIC assembly 2 60501030 60501030 Star coupler kit 1 FR10860 FR10860 Control fan ASIC fan 2 01096 01096 Control module
188. 7E May 2014 www eaton com V6 T2 269 V6 T2 269 V6 T2 270 V6 T2 270 V6 T2 270 V6 T2 272 V6 T2 275 V6 T2 276 V6 T2 278 V6 T2 279 Inverter Unit The SPI9000 Inverter Unit is a bidirectional DC fed power inverter for the supply and control of AC motors The inverter is supplied from a common DC bus drive line up A charging circuit is needed in case a connection to a live DC bus is required The DC side charging circuit is integrated up to 75 kW FR4 FR8 and external for higher power ratings FI9 FI14 Adjustable Freguency Drives 7 0 SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Application Description The common DC bus product portfolio fulfills all solution demands with a flexible architecture Front end units are selected according to the level of harmonics and power requirements Typical drive system configurations are illustrated the following figures SPA Inverters SPN Inverters Combination Configuration Active Non regenerative Non regenerative Active Front End Front End Front End Front End SPA SPN SPN Alternative SPA Alternative N w IXY 3 13 3 3 1 Y K K 2 2 2 2 5 2 2 2 2 2 Common Bus 2 2 TH 13 1 3 3 3 3 3 1 Ny N NS N Inverter Inverter Inverter Inverter
189. 8 CPX07534DA 100 140 FR8 CPX10034DA 125 170 FR8 CPX12534DA 8 150 205 FR9 CPX15034DA 200 245 FR CPX20034DA Notes All Type drives use the Size F enclosure See enclosure dimensions beginning Page 6 2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 233 2 8 Adjustable Frequency Drives CPX9000 Drives 575V Drives GPX9000Drive 1 9000 Base Drive Type 1 a Enclosure Current Chassis Base Catalog Size hp 2 A Frame Number Low Overload Drive 7 25 27 FR6 CPX02515AA 30 34 FR6 CPX03015AA 40 41 FR7 CPX04015AA 50 52 FR7 CPX05015AA 60 62 FR8 CPX06015AA 75 80 FR8 CPX07515AA 100 100 FR8 CPX10015AA 8 125 125 FR9 12515 150 144 FR9 15015 200 208 FR9 20015 9 250 261 FR10 25015 300 325 FR10 CPX30015AA 400 385 FR10 CPX40015AA 10 500 502 FR11 CPX50015AA 600 590 FR11 CPX60015AA 11 650 650 FR12 CPX65015AA 700 750 FR12 CPX70015AA 800 820 FR12 CPX80015AA High Overload Drive 7 25 27 FR6 CPX02515DA 30 34 FR7 CPX03015DA 40 41 FR7 CPX04015DA 50 52 FR8 CPX05015DA 60 62 FR8 CPX06015DA 75 80 FR8 CPX07515DA 8 100
190. 80V 5 575V V6 T2 270 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 0 SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Non Regenerative Front End 510A0 4A3N1 Product Family Board Modifications SPN Non regenerative 1 Standard boards front end 2 Varnished boards Current Rating Brake Chopper Options 480V 575V N brake chopper circuit 510 5104 Level Software Series 3 IT network Standard Keypad A Alphanumeric Enclosure Rating _ 0 Chassis Voltage Rating 4 480V 5 575V SPI9000 Inverter Unit Product Family Board Modifications SPI Inverter unit 1 Standard boards 2 Varnished boards Current Rating 480V 4 8 575V FR6 FR8 Brake Chopper Options 003 3 3A 031 31 003 3 2A 022 22A N No brake chopper circuit 007 7 6A 038 38A 004 4 5A 027 27A 009 061 61 005 5 5A 034 34A 012 12A 071 72 007 7 5 041 41 Level 016 16 087 87 010 10A 052 52A 3 IT network 023 23A 105 105A 013 13 5A 062 62A 018 18A 080 80A 480V
191. 9 1992 small 50 horsepower Provides increased input protection for AFD and its semiconductors from line transients Up to four times the harmonic reduction of 12 pulse methods Smaller transformer than isolation transformer used in 12 pulse converter CA08100007E May 2014 www eaton com Features and Benefits CPX9000 clean power drive features include Space optimized enclosure Simple layout for power options Type 1 NEMA 12 with gaskets and filters Type 3R Input voltage 480V 208V 575V Complete range of control Adjustable Frequency Drives Horsepower range e 480V 25 800 hp consult factory for larger sizes 208 230V 25 200 hp 575V 25 800 hp consult factory for larger sizes Over 15 years of 18 pulse clean power experience 65 kAIC Standard at 480V and 208V 100 kAIC optional CPX9000 Drives Standards and Certifications UL 508C tested listed and approved 2 8 network and power options Product Identification Type 1 25 150 hp 30 x 90 x 21 50 SVX9000 Drive I Bypass Starter Assembly c option Motor Circuit Protector standard with bypass options Door Mounted Keypad Pre Charge Input Contactor 18 Pulse Diode Rectifier Input Line Fuses Pa Input 18 Pulse Auto Transformer Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 227 28 9000 Dr
192. 9000 Drives LCX9000 Liquid Cooled Adjustable Frequency Drives Product Description Features and Benefits Contents Description LCX9000 Drives Catalog Number Selection Product Selection maas dedo Technical Data and Specifications Wiring Diagrams Dimensions Standards Certifications CE mark ensures CE The LCX9000 Liquid Cooled Drive family continues Eaton s tradition of providing state of the industry products by taking advantage of liquid cooling technology in lieu of air cooling techniques The LCX9000 drives are liquid cooled products that utilize potable water or a water glycol mixture as a cooling medium Compact size and low heat transfer rates allow enclosure size to be greatly reduced which is especially beneficial in UL Type 4X applications Directive LVD Design 15 modular with Reliable drive with over control and power modules 500 000 hours MTBF independent of each other based on MIL 217 Connection between Currently supports power and control modules DeviceNet PROFIBUS DP can be direct or extended Modbus RTU and Modbus via a fiber optic cable TCP communication compliance with the Electromagnetic Compatibility Directive Same reliable control protocols module and operating Separately mounted line system as the SPX9000 reactor included with A
193. 92 170 HMX32AG20522 N 9 261 100 75 248 205 HMX32AG26122 N 310 125 90 N A 261 HMX32AG31022 N Note For sizing reference V6 T2 164 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 6 H Max Series Drives H Max Series Drives 480 Vac NEMAType1 1 IP21 FS Drive Output Current Assigned Motor Ratings Frame Low Overload Full Drive kW 480 Vac Low Overload Full Catalog Size Load Amps at 40 Horsepower 400 Vac 50 Hz Amps Load Amps at 50 C Number 4 34 1 5 1 1 21 2 6 4 630421 48 2 1 5 34 34 HMX34AG4D821 N 5 6 3 2 2 5 6 4 8 HMX34AG5D621 N 8 0 4 3 0 N A 5 6 HMX34AG8D021 N 9 6 5 4 7 6 8 HMX34AG9D621 N 12 75 5 5 11 9 6 HMX34AG01221 N 5 16 10 75 14 12 HMX34AG01621 N 23 15 11 21 16 HMX34AG02321 N 31 20 15 27 23 HMX34AG03121 N 6 38 25 18 5 34 31 HMX34AG03821 N 46 30 22 40 38 HMX34AG04621 N 61 40 30 52 46 HMX34AG06121 N 7 72 50 37 65 61 HMX34AG07221 N 87 60 45 77 72 HMX34AG08721 N 105 75 55 96 87 HMX34AG10521 N 8 140 100 75 124 105 HMX34AG14021 N 170 125 90 156 140 HMX34AG17021 N 205 150 110 180 170 HMX34AG20521 N 9 261 200 132 240 205 HMX34AG26121 N 310 250 160 302 261 HMX34AG31021 N NEMA ype 12 NEMA 12 1 54 FS Drive Output Current Assigned Motor Ratings Low Overload Full Dr
194. 96 max 50 mA Reference voltage 10V 2396 max 10 mA Analog current output 0 4 20 mA R 500 kohms resolution 10 bit accuracy lt 2 Analog voltage output 0 2 10V 21 kohms resolution 10 bit accuracy lt 2 Relay output Maximum switching voltage 300 Vdc 250 Vac Maximum switching load 8A 24 0 4 300 2 250 Maximum continuous load 2A rms Thermistor input 4 7 kohms Encoder input 24V 0 lt 10V 1 gt 18V 2 2 kohms 5V 0 lt 2V 1 23V 330 ohms Note Some horsepower units include dynamic braking chopper as standard refer to individual drive sections CA08100007E May 2014 www eaton com V6 T2 87 2 4 Dimensions Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm 9000X Enclosed Drives Size 0 1 50 38 1 For Cable Lifting Holes K K Entry 4 Places p A gt A 1 8 y fl A A U E I Y d H 5 B ooo E A F A T gt Top View For Cable DM O Y 19 Y lt hp D 0 44 11 2 Mounting Holes 4 Places NEMA Type 1 1P21 NEMA Type 12 1P54 Bottom View NEMA Type 12 1P54 Includes Cover
195. A 9 2 ext 24 Vdc ext 24 Extended 1 0 Cards 6D B C D E 1 B1 1 NC N0 1 1 therm D E 0 2 B2 1 Al mA isolated 2 AO mA isolated BCDE 0PTB4 4 u u u u u u u 30 NO B C D E OPTB5 B5 3 Pt100 RTD board D E OPTB8 B8 1 RO NO 5 DI 42 240 input C D E OPTB9 B9 Communication Cards Modbus D E OPTC2 cz Modbus TCP D E Cl u u BACnet D E EtherNet IP DE OPTCQ ca u Johnson Controls N2 D E OPTC2 CA m PROFIBUS DP D E LonWorks D E OPTC4 C4 PROFIBUS DP 09 connector D E 5 C5 u CANopen slave D E 6 C6 DeviceNet D E OPTC7 C7 u Modbus 09 type DE OPTC8 C8 RS 232 with 09 connection D E OPTD3 D3 Notes Analog Input AO Analog Output DI Digital Input DO Digital Output Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 237 2 8 9000 Drives Modbus RTU Network Communications The Modbus Network Card
196. A Build options alphabetically and numerically L L gt Product Software Series Extended 1 0 Options in Slot D and E HMX HVAC drive VT A Z B1 6 x 01 00 Each digital input can be individually low overload programmed as digital output B2 1RO NC N0 1RO NO 1 Thermistor B4 1xAI 2 isolated NEC Ampere Ratings Braking Application B5 3xRO 208 Volts 480 Volts N No brake chopper B9 180 NO 5 DI 42 240 Vac input 406 4 6A 1 hp 201 21A 1 hp low overload BF Expander IO 1 AO 1 DO 1 RO 7D5 7 5A 2 hp 304 3 4A 2 hp 011 11A 3 hp 5D6 5 6A 3 hp 017 17A 5 hp 7D6 7 6A 5 hp Voltage Optional Communications in Slot D and E 025 25A 7 5 hp 011 11A 7 5 hp 1 208V C4 LonWorks 031 31A 10 hp 014 14A 10 hp 2 230V 047 74 15 hp 021 21A 15 hp 4 480V 060 60A 20 hp 027 27A 20 hp EMC Upgrade Option Keypad Options 075 75A 25 h 034 34A 25 h ARENIE hp Enclosure Style 2 Standard None available 230 Volts 052 52A 40 hp 3 IntelliPass NEMA Type 1 402 42A 1 hp 065 65 50 hp 4 Inte liPass NEMA Type 12 IntelliDisconnect Options 608 6 8A 2 hp zc ZMP Pilot lights Power ON RUN Fault 4 096 96A 75 hp A IntelliDisconnect NEMA Type
197. A Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure All Type 3R drives use the Size F enclosure V6 T2 230 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 8 9000 Drives 480V Drives 9000 Drive CPX9000 Base Drive 1 Enclosure Current Chassis Base Catalog Size hp O A Frame Number Low Overload Drive 7 25 38 FR6 CPX02514BA 30 46 FR6 03014 40 61 FR6 04014 50 72 FR7 CPX05014AA 60 87 FR7 CPX06014AA 75 105 FR7 CPX07514AA 100 140 FR8 CPX10014AA 125 170 FR8 CPX12514AA 150 205 FR8 CPX15014AA 8 200 261 FR9 CPX20014AA 250 300 FR9 CPX25014AA 9 300 385 FR10 CPX30014AA 350 460 FR10 CPX35014AA 400 520 FR10 40014 10 500 590 FR11 CPX50014AA 550 650 FR11 CPX55014AA 600 730 FR11 CPX60014AA 11 650 820 FR11 CPX65014AA 700 920 FR12 CPX70014AA 800 1030 FR12 CPX80014AA High Overload Drive 7 25 38 FR6 CPX02514EA 30 46 FR6 CPX03014EA 40 61 FR7 CPX04014DA 50 72 FR7 CPX05014DA 60 87 FR7 CPX06014DA 75 105 FR8 CPX07514DA 100 140 FR8 CPX10014DA 125 170 FR8 CPX12514DA 8 150 205 FR9 CPX1
198. A3N2 87 79 58 45 CH4 LCX087A0 4A3N2 105 95 70 55 CH4 LCX105A0 4A3N2 140 127 93 75 CH4 LCX140A0 4A3N2 168 153 112 90 CH5 LCX168A0 4A3N2 205 186 137 110 CH5 LCX205A0 4A3N2 261 237 174 132 CH5 LCX261A0 4A3N2 300 273 200 160 CH61 LCX300A0 4A3N2 385 350 257 200 CH61 LCX385A0 4A3N2 460 418 307 250 CH72 LCX460A0 4A3N2 520 473 347 250 CH72 LCX520A0 4A3N2 590 536 393 315 CH72 LCX590A0 4A3N2 650 591 433 355 CH72 LCX650A0 4A3N2 730 664 487 400 CH72 LCX730A0 4A3N2 820 745 547 450 CH63 LCX820A0 4A3N2 920 836 613 500 CH63 LCX920A0 4A3N2 1030 936 687 560 CH63 LCXH10A0 4A3N2 1150 1045 766 600 CH63 LCXH11A0 4A3N2 1370 1245 913 700 CH74 LCXH13A0 4A3N2 1640 1491 1093 900 CH74 LCXH16A0 4A3N2 2060 1873 1373 1100 CH74 LCXH20A0 4A3N2 2300 2091 1533 1200 CH74 LCXH23A0 4A3N2 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 253 7 9 Adjustable Frequency Drives LCX9000 Drives LCX9000 Liquid Cooled 525 690 Vac Liquid Cooled Drives Drives Motor Output Current Thermal 1 A A ly A kW Chassis Catalog Number 170 155 113 110 CH61 LCX170A0 5A3N2 208 189 139 132 CH61 LCX208A0 5A3N2 261 237 174 160 CH72 LCX261A0 5A3N2 325 295 217 200 CH72 LCX325A0 5A3N2 385 350 257 250 CH72 LCX385A0 5A3N2 416 378 277 250 CH72 LCX416A0 5A3N2 460 418 307 300 CH72 LCX460A0 5A3N2 502 456 335 355 CH72 LCX502A0 5A3N2 590 536 393
199. AA4D3_ MMX34AA5D6_ MMX11AA4D8_ 3 94 2 95 9 96 953 134 441 217 FS3 MMX12AA9D6_ 100 75 253 242 34 112 5 5 MMX32AA011_ MMX34AA7D6_ MMX34AA9D0_ MMX34AA012_ MMX34AA014_ MMX35AA1D7_ MMX35AA2D7_ MMX35AA3D9_ MMX35AA6D1_ MMX35AA9D0_ MMX32AA012_ 6 50 5 51 14 57 13 82 13 27 6 61 0 28 0 55 FS4 MMX32AA017_ 165 0 140 0 370 0 351 0 337 0 168 0 7 0 14 0 MMX32AA025_ MMX34AA016_ MMX34AA023_ MMX32AA031_ 6 50 5 51 14 57 13 82 15 08 8 07 0 28 0 55 FS5 MMX32AA038_ 165 0 140 0 414 0 398 0 383 0 205 0 7 0 14 0 MMX34AA031_ MMX34AA038_ Note 1 in 25 4 mm 1 mm 0 0394 in Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 31 2 3 Adjustable Freguency Drives Series Adjustable Freguency Drives Approximate Dimensions Inches mm E NEMA 1 IP21 M Max Drives and Communication Adapter Kit W3 w2 O O O H 4 Frame Type H W1 W2 W3 D FS1 8 14 206 7 3 77 95 7 2 99 75 9 3 98 101 2 5 41 137 5 FS2 9 90 251 5 4 72 120 0 3 97 100 8 4 94 125 5 5 68 144 2 FS3 12 26 311 5 5 12 130 1 4 36 110 8 5 33 135 3 6 32 160 5 V6 T2 32 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives SVX9000 Drives Product Overvie
200. ACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It includes a 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Analog Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 127 EtherNet IP Network Communications The EtherNet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters CIP is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable by Static BOOTP and DHCP methods 2 4 V6 T2 107 2 4 Adjustable Freguency Drives 5 9000 Drives Control Communication Option Descriptions For availability see Product Selection for base drive voltage required Available Control Communications Options Option Description Option Type K1 Door Mounted Speed Potentiometer Provides the SVX9000 with the ability to adjust the frequency reference using a door mounted potentiometer This option uses Contro the 10 Vdc
201. According to 15011898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay of nominal 5 nS m 120 ohms line termination resistors required for installation Adjustable Frequency Drives SVX9000 Drives DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The N2 fieldbus is available as a factory installed option and as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable over Ethernet using a supplied softw
202. Adjustable Frequency Drives M Max 2 1 NFX9000 Drives Pr dutt EAE ERA V6 T2 2 Produit aana gkah ag V6 T2 3 2 2 PowerXL DC1 DA1 Series Adjustable Frequency AC Drives qx was 6 2 8 Product SS V6 T2 10 2 3 M Max Series Adjustable Frequency AC Drives 4 244646466 646446 4686 ees V6 T2 23 Product Selection de es s saa aaa V6 T2 25 2 4 SVX9000 Drives V6 T2 33 SVX9000 Open Drives H Max Product DEZE DOGM 22 ceed eden Qt be dud oder Seded quqa V6 T2 36 Produet V6 T2 38 SVX9000 Enclosed Drives Product V6 T2 75 FioductSSlEGNO 2225 4 as V6 T2 78 SVX9000 VFD Pump Panels PIQUE Jokes Ohad Ex I SAO DS V6 T2 99 i ue du V6 T2 101 2 5 SPX9000 Drives ZKP a EE EE de RR Edad V6 T2 119 Product bred ERR E QURE V6 T2 122 2 6 H Max Series Drives debes qe i ira REA eag eq wed dan V6 T2 161 CPX9000 H Max Drives Product DESC pun 5205 PRECII Reka V6 T2 162 Product S8IBCUGW V6 T2 164 H Max IntelliPass and IntelliDisconnect Driv
203. BR R030 W015K 28W x 16D x 10H 30 18 0 DBR R020 W4800 26 5W x 13D x 5H DBR R020 W020K 30W x 18D x 16H 40 18 0 DBR R030 W6000 26 5W x 16D x 5H DBR R184 W025K 30W x 18D x 16H 50 9 0 DBR R013 W7500 26 5W x 16D x 5H DBR R012 W030K 30W x 18D x 24H 60 9 0 DBR R010 W9000 28W x 10D x 10H DBR R010 W036K 30W x 18D x 24H 75 9 0 DBR R009 W012K 28W x 13D x 10H DBR R009 W045K 30W x 18D x 24H 100 7 0 DBR R013 W015K 28W x 16D x 10H DBR R8D4 W060K 30W x 18D x 40H 125 7 0 DBR R8D2 W020K 30W x 18D x 10H DBR R007 W070K 30W x 18D x 40H 150 7 0 DBR R007 WO25K 30W x 18D x 16H DBR R006 WO85K 30W x 18D x 56H 175 7 0 DBR R007 W030K 30W x 18D x 24H DBR R007 W100K 30W x 18D x 72H 200 25 DBR R3D3 W030K 30W x 18D 24 DBR R2D6 W110K 30W x 18D x 64H 250 25 DBR R2D5 W036K 30W x 18D x 24H DBR R003 W140K 30W x 180 x 72H 300 2 5 DBR R3D3 W045K 30W x 18D x 32H O 400 1 7 DBR R002 W060K 30W x 18D x 48H O 450 13 DBR R1D8 W070K 30W x 18D x 48H O 500 13 DBR R002 WO80K 30W x 18D x 56H O Note Consult factory V6 T2 48 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Replacement Parts FR4 Spare Parts Adjustable Freguency Drives SVX9000 Drives Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 PP01086 PP01086 Control module SVX control module 1 CSBS0000
204. C air cooled drives fed models Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com EMO and the Low Voltage 2 9 Page V6 12 252 V6 T2 253 V6 T2 256 V6 T2 258 V6 T2 259 V6 12 261 V6 T2 251 7 9 Adjustable Freguency Drives LCX9000 Drives Catalog Number Selection LCX9000 Liquid Cooled Adjustable Frequency Drives Lex 016 A 0 4A3B 2 bu Y Product Family a Options LCX High performance liquid cooled drive List options in alphabetical order Extended 1 0 Card Options 2 therm _ 4 Encoder low volt 5V 15V 24V Current Rating A5 Encoder high volt 15V 24V 480V A1 Dual encoder 15V 24V A8 6 DI 100 2 AI 016 16A 385 385A DI 022 22A 460 460A AE Encoder with 2 00 031 31A 520 5204 Software Series B1 601 1 ext 24 Vdc EXT 24 038 38A 590 590A A Standard B2 1 RO NC NO 1 RO 1 therm 045 45A 650 650A 4 1 Al mA isolated 2 AO mA isolated 061 61 730 7304 ext 24 Vdc EXT 24 Vdc 072 72A 820 820A Bee RONO 087 87 920 920A Enclosure Rating B8 1 ext 24 Vdc EXT 24 100 105 105A H10 1030A 0 Open chassis B9 1 RO 5 DI 42 240 Vac input 140 1404 H11 1150A BB SPI absolute enc
205. CFX05015DA CFX05065DA CFX05035DA 60 62 FR8 CFX06015DA CFX06065DA CFX06035DA 75 77 FR8 CFX07515DA CFX07565DA CFX07535DA 100 99 FR9 CFX10015DA CFX10065DA CFX10035DA 125 125 FR9 CFX12515DA CFX12565DA CFX12535DA 150 144 FR9 CFX15015DA CFX15065DA CFX15035DA 200 192 FR10 CFX20015DA CFX20065DA 250 242 FR10 CFX25015DA CFX25065DA 300 289 FR10 CFX30015DA CFX30065DA Notes FR6 FR7 drives not available in UL Type 1 Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 7 CFX9000 Drives CFX9000 Enclosure Chassis 1 UL Type 12 UL Type 3R Frame Disconnect Only With Power Options Disconnect Only With Power Options Disconnect Only With Power Options FR6 N A N A B FR7 N A 7 C 7 D FR8 7 7 7 7 F F FR9 8 8 8 8 F F FR10 9 9 9 9 Enclosure Dimension Drawings Enclosure Size UL Type 1 and UL Type 12 UL Type 38 B See Page V6 T2 212 See Page V6 T2 214 See Page 6 2 213 See Page V6 T2 215 D N A See Page V6 T2 216 F N A See Page V6 T2 217 70 See Page V6 T2 218 80 See V6 T2 219 9 See Page V6 T2 220 Notes Consult factory Enclosures 7 and 8 are NEMA 12 filtered Not available for UL Type Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 203 2 7 Adjustable Freguency Drives CFX9000 Drives Options CFX9000 Series Option Board Ki
206. CFX06032AA 75 192 FR8 CFX07512AA CFX07562AA CFX07532AA 100 248 FR9 CFX10012AA CFX10062AA CFX10032AA High Overload Drive 7 1 2 22 FR5 CFX00722EA CFX00732EA 10 28 FR6 CFX01022EA CFX01032EA 15 42 FR6 CFX01522EA CFX01532EA 20 54 FR7 CFX02022DA CFX02032DA 25 68 FR7 CFX02522DA CFX02532DA 30 80 FR7 CFX03022DA CFX03032DA 40 104 FR8 CFX04012DA CFX04062DA CFX04032DA 50 130 FR8 CFX05012DA CFX05062DA CFX05032DA 60 154 FR8 CFX06012DA CFX06062DA CFX06032DA 75 192 FR9 CFX07512DA CFX07562DA CFX07532DA 100 248 FR9 CFX10012DA CFX10062DA CFX10032DA CFX9000 Enclosure Chassis UL Type 1 UL Type 12 UL Type 3R Frame Disconnect Only With Power Options Disconnect Only With Power Options Disconnect Only With Power Options FR4 N A N A B FR5 N A N A B C B C FR6 N A N A B C FR7 N A 7 C 7 D FR8 7 7 7 7 F FR9 8 8 8 8 F F Enclosure Dimension Drawings Enclosure Size UL Type 1 and UL Type 12 UL Type 3R B See Page V6 T2 212 See Page V6 T2 214 See Page 6 2 213 See Page V6 T2 215 D N A See Page V6 T2 216 F N A See Page V6 T2 217 70 See V6 T2 218 8 Page 6 2 219 9 See Page V6 T2 220 Notes FR5 FR7 drives not available in UL Type 1 Enclosures 7 and 8 are NEMA 12 filtered Not available for UL Type Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton c
207. Catalog Number Dimensions Inches Adjustable Frequency Drives SVX9000 Drives 50 Duty Cycle 150 Torque Catalog Number Dimensions Inches 1 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W0800 12W x 7D x 5H 1 5 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 2 63 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 3 63 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2000 12W x 16D x 5H 5 63 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2800 19W x 13D x 5H 6 63 0 DBR R100 W1200 12W x 10D x 5H DBR R070 W4000 19W x 16D x5H 75 63 0 DBR R100 W1200 12W x 10D x 5H DBR R063 W4800 26 5W x 13D x 5H 10 63 0 DBR R063 W1600 12W x 13D x5H DBR R063 W6000 26 5W x 16D x 5H 15 42 0 DBR R042 W2400 19W x 10D x5H DBR R042 W9000 28W x 10D x 10H 20 21 0 DBR R030 W3200 19W x 13D x5H DBR R023 W012K 28W x 13D x 10H 25 21 0 DBR R030 W4000 19W x 16D x5H DBR R021 W015K 28W x 13D x 10H 30 14 0 DBR R020 W4800 26 5W x 13D x 5H DBR R014 WO20K 30W x 18D x 24H 40 6 5 DBR R112 W6000 26 5W x 13D x 5H DBR R007 WO25K 30W x 18D x 16H 50 6 5 DBR R013 W7500 26 5W x 16D x 5H DBR R8D5 W030K 30W x 18D x 24H 60 6 5 DBR R010 W9000 28W x 10D x 10H DBR R7D3 W036K 30W x 18D x 24H 75 33 DBR R009 W012K 28W x 130 x 10H DBR R3D3 W045K 30W x 18D x 32H 100 3 3 DBR R5D1 W015K 28W x 16D x 10H DBR R004 WO60K 30W x 18D x 40H 125 33 DBR R4D1 W020K 28W x 16D x 10H DBR R004 W070K 30W x 18
208. Control nput phase supervision Trips if any of the input phases are missing otor phase supervision rips if any of the output phases are missing Overtemperature protection Yes otor overload protection Yes otor stall protection Yes otor underload protection Yes Short circuit protection Yes 24 and 10V reference voltages Standard Specifications Description Six digital input programmable Specification 24V 0 10V 1 218VR gt 5 kohms Two analog input configurable w jumpers Voltage 0 10V gt 200 kohms Current 0 4 20 mA 250 ohms Two digital output programmable Form relays 250 30 Vdc 2 amp resistive One analog output programmable configurable w jumper 5 0 20 mA max 500 ohms 10 bits 2 One digital output programmable Open collector 48 Vdc 50 mA CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 SVX9000 Drives Dimensions Approximate Dimensions Inches mm 9000 Drives NEMA Type 1 IP21 NEMA Type 12 IP54 FR5 and FR6 1 lt D1 E W2 2 jg R1 Cutter Hammer AC H1 H3 d P pe y R2
209. Copy paste functionality on drive keypad allows for fast setup of multiple drives e Pre programmed 1 0 supports fast easy installation for most applications CA08100007E May 2014 www eaton com Page V6 T2 163 V6 T2 164 V6 T2 167 V6 T2 167 V6 T2 168 V6 T2 169 V6 T2 170 V6 T2 171 Standards and Certifications Product EC 61800 5 1 UL508C cUL e C Tick Mark OSHPD Seismic Certified Plenum Rated W W Adjustable Freguency Drives 2 6 Series Drives Catalog Number Selection Series Drives 4D8 4 8A 1 hp 0 75 kW 606 6 6A 1 5 hp 1 1 kW 8D0 8A 2 hp 1 5 kW 011 11A 3 hp 2 2 KW 012 12A 4 hp 3 kW 018 18A 5 hp 4 kW 024 24A 7 5 hp 5 5 kW 031 31A 10 hp 7 5 kW 048 48A 15 11 KW 075 75 25 hp 18 5 kW 088 88A 30 hp 22 kW 105 105A 40 hp 30 kW 140 140A 50 hp 37 KW 170 1704 60 hp 45 kW 205 205 75 hp 55 kW 261 261A 100 hp 75 kW 310 310A 125 hp 90 kW 408 4 8 2 hp 1 5 kW 506 5 6 3 hp 2 2 kW 800 8A 4 hp kW 906 9 6 5 hp 4 kW 012 12 7 5 hp 5 5 kW 016 16 10 hp 7 5 kW 023 23A 15 hp 11 kW 031 31 20 hp 15 kW 038 38 25 hp 18 5 kW 061 072 087 105 140 170 20
210. D x 48H 150 3 3 DBR R3D4 W025K 30W x 18D x 16H DBR R3D5 WO085K 30W x 18D x 56H 200 33 DBR R3D3 W030K 30W x 18D x 24H DBR R3D3 W110K 30W x 18D x 72H 250 1 4 DBR R2D5 W036K 30W x 18D x 24H 300 1 4 DBR R1D5 W045K 30W x 18D x 32H 2 350 14 DBR R1D4 WO060K 30W x 18D x 40H 400 0 9 DBR R1D4 W060K 30W x 18D 500 0 9 DBR R0D9 W080K 30W x 18D x 48H 550 0 9 DBR R001 WO85K 30W x 18D x 56H Note Consult factory Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 4 V6 T2 47 2 4 Adjustable Freguency Drives SVX9000 Drives 575V Brake Resistors Drive hp Minimum 20 Duty Cycle 100 Torque 50 Duty Cycle 150 Torque CT lH Ohms Catalog Number Dimensions Inches Catalog Number Dimensions Inches 2 100 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 3 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2000 12W x 16D x 5H 4 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2400 19W x 10D x 5H 5 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2800 19W x 13D x 5H 75 100 0 DBR R100 W1200 12W x 10D x 5H DBR R100 W4800 26 5W x 13D x 5H 10 30 0 DBR R063 W1600 12W x 13D x5H DBR R063 W6000 26 5W x 16D x 5H 15 30 0 DBR R042 W2400 19W x 10D x5H DBR R042 W9000 28W x 10D x 10H 20 30 0 DBR R030 W3200 19W x 13D x5H DBR R030 W012K 28W x 13D x 10H 25 30 0 DBR R030 W4000 19W x 16D x5H D
211. DC1 34024NB A20N Notes These are constant torque high overload rated drives For all applications select the unit such that the motor current is less than or equal to the rated continuous output current Brake chopper circuit available as standard in frames 2 and 3 version available Substitute with DC1 F for this option V6 T2 10 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency AC Drives IP66 DC1 Series 66 Enclosure Drives 100 Continuous Frame hp O kW Volts Current In A Size 9 Catalog Number 05 037 iVsmgephaei 7 DCI SI7DONN AGSN 075 055 put 105 2 DC1 S1011NB A6SN 05 037 200 240 single phase inf 43 1 DC1 S24D3NN A6SN 1 075 1 DC1 S27D0NN A6SN 29 15 11 10 2 DC1 S2011NB A6SN 29 1266 05 037 115V single phase in 23 1 DC1 1D2D3NN A6SN 1 075 230V three phase aut 43 1 DC1 1D4D3NN A6SN 15 11 58 2 DC1 1D5D8NB A6SN 05 0 37 200 240Vsinglephasein 23 1 DC1 122D3NN A6SN 1 075 43 1 DC1 124D3NN A6SN 5 2 15 7 1 DC1 127D0NN AGSN 2 15 7 2 DC1 127D0NB A6SN 3 22 105 2 DC1 12011NB A6SN 55 5 4 15 3 DC1 12015NB A6SN 05 037 200 240V three phase in 23 1 DC1 322D3NN A6SN 1 0 75 2908 hice 43 1 DC1 324D3NN A6SN 2 15 7 1 DC1 327D0N
212. Down NEMA Type 12 IP54 software driver disk FS4 N12 IP54 flange kit FS4 Flange N12KIT mounting N1 drive into 12 enclosure Replacement Relay Board Slot FS5 N12 IP54 flange kit FS5 Flange N12KIT Catalog mounting 1 drive into N12 enclosure Description Number FS6 N12 IP54 flange kit FS6 Flange N12KIT Replacement relay board Relay board 1 mounting N1 drive into N12 enclosure qty 2 Form C relay qty 1 Form A relay FS7 N12 IP54 flange kit FS7 Flange N12KIT mounting N1 drive into N12 enclosure Main Fan Catalog Description Number Keypad Accessories FS4 main fan FS4 Main Fan Remote Mounting Keypad Kit FS5 main fan FS5 Main Fan S S FS6 main fan FS6 Main Fan mames Tees FS7 main fan FS7 Main Fan Catalog Description Number Internal Fan Remote mounting keypad kit bezel and cable OPTRMT BP HMAX Catalog Description Number Drive Demo FS4 internal fan IP54 NEMA 12 FS4 Internal Fan FS5 internal fan IP54 NEMA 12 FS5 Internal Fan H Max Series Drive Demo FS6 internal fan IP54 NEMA 12 FS6 Internal Fan Demos and Power Supply FS7 internal fan IP54 NEMA 12 FS7 Internal Fan Catalog Description Number H Max Series bypass demo H MAX BYPASS DEMO Hand held 24V auxiliary power supply used to supply power 9000XAUX24V to the control module in order to perform keypad programming before the drive is connected to line voltage Notes For installation of a NEMA Type 1 drive into a NEMA Type 12 oversized enclosure Frame size 8 a
213. FR13 2 x CHK0400 SPX 900 4 3 x CHK0520 SPX 900 5 2 x CHK0400 SPX H10 4 3 x CHK0520 SPX H105 2 x CHK0400 SPX 12 4 FR14 4 x CHK0520 SPX H135 FR14 4 x CHK0400 SPX H16 4 6 x CHK0400 SPX H155 6 x CHK0400 CHK0520 1 p K 9 lol 191 jo El A 650 650 165 165 24 6 8 03 204 1 69 19 57 i 43 497 gt n 1 n 1 6 1 0 Ex Ami r 1 FEM m 79 1257 20 15 71 446 1 58 399 3 03 40 7 77 Y 3 3 3 I LJ 8 Tp 21 9 U im T U Y 20 o o Y Y 5 70 7 88 200 9 61 244 lt 55 14 Note Chokes are provided with all FR10 FR14 drives Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 159 2 5 Adjustable Frequency Drives SPX9000 Drives Approximate Dimensions in Inches mm CHK0400 4 72 4 72 A 42 ui
214. Frequency Drives Catalog Catalog Description Number Suffix Description Number Suffix 100 kA surge protective device P9 Bypass test switch used with RA and RB KF Inverter bypass pilot lights 12 480 and 575V Power Options 7 1 2 400 hp Meter Options Catalog Catalog Description Number Suffix Description Number Suffix nput breaker P1 Standard elapsed time meter KO nput line fusing p2 Freguency meter KS nput line fuses 200 kAIC P3 MP 3000 relay with URTD KV Output contactor PE MP 3000 relay with URTD and CTs KU Dutput filter PF otoRx 300 600 ft DV DT filter PG Enclosure Options Single overload relay PH Enclosure Catalog Size Number Suffix Dual overload relays Space D nput MOV P7 7 9 50 surge protective device 8 89 100 surge protective device P9 9 S9 B S9 C S9 208V Bypass Options 7 1 2 100 hp D S9 Catalog Description Number Suffix F S9 Plastic Nameplate Manual HOA bypass controller RA All SN 108 bypass controller RB Floor Stand Enclosure Size Auto transfer HOA bypass controller RC 6 in floor stand size F 54 Auto transfer bypass controller RD 22 in floor stand size and S5 Reduced voltage starter for bypass RG 12 in floor stand size C and D S6 Dual overloads for bypass PN 230V B
215. H3 H4 H5 H6 H7 D1 D2 D3 Dia 20 9 530 20 0 510 19 1 485 7 9 200 0 2 55 51 7 1312 45 3 1150 16 5 420 33000 1 4 35 0 4 9 0 1 2 24 9 362 13 4 340 4 3 109 0 8 21 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 151 2 5 Adjustable Frequency Drives SPX9000 Drives Approximate Dimensions in Inches mm Type 1 IP21 and NEMA Type 12 IP54 FR10 Freestanding W7 W5 0 gt gt 5 W6 W6 o o 4 lt lt lt WA len 9 o o N i 3 qe ones D3 p2 06 07 OJ D5 UE D4 2 lt gt lt gt lt gt lt gt I lt W3 W3 W3 W3 W2 lt W1 lt D1 gt Mmm o EJ EE 0 L H1 H2 Operator Shown with Optional 5 4 B Disconnect Y Y 5 5 5 E Weight Volts ly wi 2 W W W WG W H H2 H3 D1 D2 D3 D4 D5 D6 D7 Dia 1 Dia 2 Dia 3 Lbs kg 480V 250 350 2343 246 453 079 5 95 2 95 3011 7945 7480 20 18 23 70 17 44 19 00 047 11 22 17 60 20 08 0 83 1 89 043 8751389 sony onan 595 62 5 115 20 151 75 79 2018 1900 512 5 602 443 483 12 285 447 510 21 48 11 690V 200 300 V6 T2 152 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjusta
216. IGBT Section 500 hp Six Pulse Nonproductive Harmonic Current Current Amps 1000 500 500 1000 0 100 0 10625 0 1125 0 11875 0 125 Time Seconds 500 hp Six Pulse Nonproductive Harmonic Current Six Pulse Circuit Current harmonics 100 1 6 10 lige 1 77 l 22 5 lg 4 06 Ig 1 12 9 38 l 2 26 ls 0 86 Power 500 hp Harmonic current 167 amps Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 8 9000 Drives Guidelines of Meeting IEEE Std 519 1992 Harmonic Distortion Limits The IEEE 519 1992 Specification is a standard that provides guidelines for commercial and industrial users that are implementing medium and low voltage equipment Maximum Harmonic Current Distortion in of the Fundamental 120V through 69 000V Harmonic Order Odd Harmonics Isc l h lt 11 11 lt h lt 17 17 lt lt 23 23 lt lt 355 35 lt TDD lt 20 4 0 2 0 1 5 0 6 0 3 5 0 20 lt 50 7 0 3 5 2 5 1 0 0 5 8 0 50 lt 100 10 0 4 5 4 0 1 5 0 7 12 0 100 lt 1000 12 0 5 5 5 0 2 0 1 0 15 0 gt 1000 15 0 7 0 6 0 25 1 4 20 0 The ratio Isc l is the ratio of the short circuit current available at the point of common coupling PCC to the maximum fundamental load current Consequently as the size of the user load decreases with respect to the size of the system the percentage of harmonic current that
217. Keypad k Elements _ lai Elements J When IN C4 Mounted LES Panel 90 00 2286 0 84 37 2143 0 Quarter Turn Latch four places ake vertitating HI 12 In v 3575 981 lt 3575 984 lt 30 50 774 7 80 00 2032 0 gt lt 31 75 806 5 Front View Side View lt 15 64 21 00 x 10 00 533 4 x 254 0 3973 Bottom Access 29 04 737 6 17 79 4 87 451 9 123 7 l l y t oaz 38 00 965 2 6 42 02 10673 gt 78 02 9817 12 0 1046 Cold Rolled Steel Bottom View Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 249 2 8 Adjustable Frequency Drives CPX9000 Drives Approximate Dimensions in Inches mm Enclosure Size F Type 3R Drives 25 250 hp and 25 200 hp lh 480V 25 200 hp and 25 150 hp lj 575V Drives 60 00 1524 0 lt 37 50 952 5 n 18 00 x 8 50 z L 4572 x 215 9 Exhaust Air Side Access Venting Slots Enclosure Flanged Door Stop Disconnect Supplied with 4 Keypad Located Circuit Breaker Inside Locking When Specified Enclosure Door Key Locking Three Position
218. M1565 0 690 63 2 SPI023A1 4 FR6 170M1565 0 690 63 2 SPI031A1 4 FR6 170M1567 0 690 100 2 SPI038A1 4 FR6 170M1567 0 690 100 2 SPI061A1 4 FR7 170M1570 0 690 200 2 SPI072A1 4 FR7 170M1570 0 690 200 2 SPI087A1 4 FR7 170M1571 0 690 250 2 SPI105A0 4 FR8 170M3819 DIN 690 400 2 SPI140A0 4 FR8 170M3819 DIN 690 400 2 SPI170A0 4 FR8 170M3819 DIN 690 400 2 SPI205A0 4 Fig 170M6812 DIN3 690 800 2 SPI245A0 4 9 170 6812 DIN3 690 800 2 SPI300A0 4 FI10 170M8547 3SHT 690 1250 2 SPI385A0 4 FI10 170M8547 3SHT 690 1250 2 SPI460A0 4 FI10 170M8547 3SHT 690 1250 2 SPI520A0 4 12 170 8547 3SHT 690 1250 2x2 SPI590A0 4 12 170 8547 3SHT 690 1250 2x2 SPI650A0 4 12 170 8547 3SHT 690 1250 2x2 SPI730A0 4 12 170 8547 3SHT 690 1250 2x2 SPI820A0 4 12 170 8547 3SHT 690 1250 2x2 SPI920A0 4 F112 170M8547 3SHT 690 1250 2 2 SPIH10A0 4 F113 170M8547 3SHT 690 1250 6 SPIH11A0 4 170 8547 3SHT 690 1250 6 SPIH13A0 4 F113 170M8547 3SHT 690 1250 6 SPIH16A0 4 F114 170M8547 3SHT 690 1250 2x6 SPIH19A0 4 14 170 8547 3SHT 690 1250 2x6 SPIH23A0 4 F114 170M8547 3SHT 690 1250 2x6 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 277 2 1 Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products SHT fuses can be assembled into same size DIN fuse base 5 9000 5 9000 5 19000 continued Module Component Frame Bussman Fuse Type aR Size Un V In A Oty Active Front E
219. N AGSN 2 15 7 2 DC1 327D0NB A6SN 55 3 22 105 2 DC1 32011NB A6SN 55 5 4 18 3 DC1 32018NB A6SN 1 075 380 480 three phase in 22 1 DC1 342D2NN AGSN 5 2 15 41 1 DC1 344D1NN AGSN 2 15 41 2 DC1 344D1NB A6SN 3 22 58 2 DC1 345D8NB A6SN 552 5 4 95 2 DC1 349D5NB A6SN 55 75 55 14 3 DC1 34014NB A6SN 10 75 18 3 DC1 34018NB A6SN 55 Notes These are constant torgue high overload rated drives For all applications select the unit such that the motor current is less than equal to the rated continuous output current Brake chopper circuit available as standard in frames 2 and 3 Non disconnect version available Substitute with A66N version available Substitute with DC1 F for this option Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 11 2 2 Adjustable Frequency Drives PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Po Series IP20 Enclosure Drives 9 100 Continuous Frame UE hp O kW Volts Current In A Size 9 Catalog Number 1 075 200 240V single phase in 43 2 DA1 124D3FB A20C ups J 2 15 230V three phaseaut 7 2 DA1 127D0FB A20C ka 3 22 105 2 DA1 12011FB A20C P z 1 075 200 240V three phase in 43 2 DA1 324D3FB A20C 2 15 FRIES phase out 7 2 DA1 327D0FB A20C 3 22 105 2 DA1 32011FB A20C 5 4 18 3 DA1 32018FB A20C 75 55 24 3 DA1 32024FB A20C 1 075 380 480
220. Notes Consult factory Enclosures 7 and 8 are NEMA 12 filtered Not available for UL Type Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 201 2 575V Drives SA CFX9000 Drive V6 T2 202 Adjustable Frequency Drives CFX9000 Drives UL Type 1 UL Type 12 UL Type 3R and NEMA 12 Filtered NEC Chassis ULType1 UL Type 12 and NEMA 12 Filtered UL Type 3R hp Current A Frame Base Catalog Number Base Catalog Number Base Catalog Number Low Overload Drive 15 17 FR6 CFX01525AA CFX01535AA 20 22 FR6 CFX02025AA CFX02035AA 25 27 FR6 CFX02525AA CFX02535AA 30 32 FR6 CFX03025AA CFX03035AA 40 41 FR7 CFX04025AA CFX04035AA 50 52 FR7 CFX05025AA CFX05035AA 60 62 FR8 CFX06015AA CFX06065AA CFX06035AA 75 77 FR8 CFX07515AA CFX07565AA CFX07535AA 100 99 FR8 CFX10015AA CFX10065AA CFX10035AA 125 125 FR9 CFX12515AA CFX12565AA CFX12535AA 150 144 FR9 CFX15015AA CFX15065AA CFX15035AA 200 192 FR9 CFX20015AA CFX20065AA CFX20035AA 250 242 FR10 CFX25015AA CFX25065AA 300 289 FR10 CFX30015AA CFX30065AA 400 382 FR10 CFX40015AA CFX40065AA 2 High Overload Drive 10 14 FR6 CFX01025DA CFX01035DA 15 17 FR6 CFX01525DA CFX01535DA 20 22 FR6 CFX02025DA CFX02035DA 25 27 FR6 CFX02525DA CFX02535DA 30 32 FR7 CFX03025DA CFX03035DA 40 41 FR7 CFX04025DA CFX04035DA 50 52 FR8
221. P54 Drives Frame Size hp ly Current ly hp 1 Current 11 Catalog Number T a FR6 2 3 3 3 4 5 SVX002A2 5A4N1 ec 3 45 55 SVX003A2 5A4N1 55 5 7 5 SVX004A2 5A4N1 5 7 5 7 1 2 10 SVX005A2 5A4N1 7 1 2 10 10 13 5 SVX007A2 5A4N1 10 13 5 15 18 SVX010A2 5A4N1 15 18 20 22 SVX015A2 5A4N1 20 22 25 27 SVX020A2 5A4N1 25 27 30 34 SVX025A2 5A4N1 FR7 30 34 40 41 SVX030A2 5A4N1 40 41 50 52 SVX040A2 5A4N1 FR8 50 52 60 62 SVX050A2 5A4N1 60 62 75 80 SVX060A2 5A4N1 75 80 100 100 SVX075A2 5A4N1 100 100 125 125 SVX100A2 5A4N1 125 125 150 144 SVX125A2 5A4N1 150 144 170 SVX150A2 5A4N1 170 200 208 SVX175A2 5A4N1 525 690V Open Chassis Drives Frame Size hp In Current ly hp 1 Current I Catalog Number FR10 200 208 250 261 SPX200A0 5A2N1 250 261 300 325 SPX250A0 5A2N1 300 325 400 385 SPX300A0 5A2N1 11 400 385 450 460 SPX400A0 5A2N1 450 460 500 502 SPX450A0 5A2N1 500 502 590 SPX500A0 5A2N1 FR12 590 600 650 SPX550A0 5A2N1 600 650 700 750 SPX600A0 5A2N1 700 750 800 820 SPX700A0 5A2N1 FR13 800 820 900 920 SPX800A0 5A2N1 900 920 1000 1030 SPX900A0 5A2N1 1000 1030 1250 1180 SPXH10A0 5A2N1 FR14 1350 1300 1500 1500 SPXH13A0 5A2N1 1500 1500 2000 1900 SPXH15A0 5A2N1 2000 1900 2300 2250 SPXH20A0 5A2N1 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 41 2 4 Adjustable Freguency Drives 5 9000 Drives Accessories Demo Drive and Power Supply Demo Drive and Power Supply De
222. REM KEYPAD LOC REM Main AC fan Fan assembly left 3 FI13301 FI13301 Fan AC 3 01080 01080 Fan fuse 6 PP20202 PP20202 Starting 3 S00520 S00520 Fan driver board AC 3 VB00299 VB00299 Isolation transformer 3 PP10057 PP10057 Main DC fan DC fan 4 00072 00072 DC power supply 4 01017 01017 Notes Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 56 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 14 Spare Parts Adjustable Frequency Drives SVX9000 Drives Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control ASIC board 2 00457 00457 Star coupler 1 00593 00593 ASIC assembly 2 60501030 60501030 Star coupler kit 1 FR10860 FR10860 Control fan ASIC fan 2 01096 01096 Control module SVX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot B 1 0 card 1 2 2 Power module 1 FR14 1770 4 ANV FR14 1500 5 ANV 1 FR14 2150 4 ANV FR14 1900 5 ANV 1 FR14 2700 4 ANV FR14 2250 5 ANV Driver board 6 00454 00454 Driver adapter board 2 VB00330 VB00330 Sh
223. RTER OFF BYPASS I0B 3 contactor bypass option provides a means of bypassing the SVX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter with a door mounted IOB selector switch For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked S5 Floor Stand 22 in Converts a Size A or B normally wall mounted enclosure to a floor standing enclosure with a height of 22 in 558 8 mm Enclosure S9 Space Heater without CPT Prevents condensation from forming in the enclosure when the drive is inactive or in storage Includes a thermostat for variable Enclosure temperature control A 200W heater is installed in enclosures A and B and 400W heater is installed in enclosures C and D Requires a customer supplied 115V remote supply source SA Space Heater with CPT Prevents condensation from forming in the enclosure when the drive is inactive or in storage Includes a thermostat for variable temperature Enclosure control A 200W heater is installed in enclosures A a
224. SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Power module 1 FR14 1770 4 ANV FR14 1500 5 ANV 1 FR14 2150 4 ANV FR14 1900 5 ANV 1 FR14 2700 4 ANV FR14 2250 5 ANV Driver board 6 00454 00454 Driver adapter board 2 VB00330 VB00330 Shunt board 36 VB00541 VB00516 36 VB00517 Covers Top cover 6 FI10001 FI10001 Side cover 6 FI10003 FI10003 DC section Balancing resistor 6 PP13034 PP13034 Bus capacitor 72 00335 00336 DC busbars kit 6 FI13329 FI13329 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 6 FI13301 FI13301 Fan AC 6 01080 01080 Fan fuse 12 PP20202 PP20202 Starting 6 S00520 S00520 Fan driver board AC 6 VB00299 VB00299 solation transformer 6 PP10057 PP10057 Main DC fan DC fan 6 PP00072 00072 DC power supply 6 01017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 5 V6 T2 143 2 5 Adjustable Freguency Drives 5 9000 Drives Techni
225. SVX9000 with the ability to adjust the frequency reference using a door mounted potentiometer This option uses Control the 10 Vdc reference to generate 0 10V signal at the analog voltage input signal terminal When the bypass option is added the speed is controlled when the switch is in the HAND position Without the bypass option a two position switch labeled local remote is provided on the keypad to select speed reference from the speed potentiometer or a remote speed signal K2 Door Mounted Speed Potentiometer with HOA Selector Switch Provides the SVX9000 with the ability to start stop and adjust the speed reference from Contro door mounted control devices or remotely from customer supplied inputs In HAND position the drive will start and the speed is controlled by the door mounted speed potentiometer The drive will be disabled in the OFF position When AUTO is selected the drive run and speed control commands are via user supplied dry contact and 4 20 mA signal K4 HAND OFF AUTO Switch for Non Bypass Configurations Provides three position selector switch that allows the user to select either a HAND or AUTO mode of Control operation HAND mode is defaulted to k keypad operation and AUTO mode is defaulted to control from an external terminal source These modes of operation can be configured via programming to allow for alternate combinations of start and speed sources Start and speed sources include keypad 1 0 and
226. U 69 0 48 136 18 0 8 68 2 260 48 6 8 3 0 6 0 2 0 5 0 14 113 790 782 1753 121 344 46 19 1732 660 121 172 76 152 51 127 28 298 2007 1986 V6 T2 90 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm Size 3 0 50 12 7 Lifting Eyes ae 2 Places K J gt L yf f O g KON Cable EY Entry U a LY E r H s Ir 4 z zaa A View RR 0 44 11 2 6 Mounting Holes Ei 6 Places For Cable O Entry e y O y E 5 G1 D1 D gt lt A gt E1 E F N VV NEMA Type 1 IP21 NEMA Type 12 IP54 Bottom View NEMA Type 12 IP54 Includes Cover Plates Over Louvers For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 26 4 671 77 0 1956 19 4 493 19 5 495 3 3 83 23 0 584 1 5 38 11 7 298 5 5 140 0 9 24 76 4 1939 4 0 102 3 0 76 Cable Entry Door Clearance Handle Shipping Weight L M N P R s T U w RR Lbs kg 5 3 23 4 10 0 1 3 12 9 26 4 1 5 8 0 4 8 6 8 79 5 13 40 0 8 1 3 26 0 690 313 133 594 254 32 328 669 38 203 1
227. UL Type 3R 6 12 filtered Voltage Rating 1 208V 2 2300 4 480V 5 575V 575 600V Application Torque Braking brake chopper internal brake chopper D l no brake chopper y internal brake chopper Brake chopper is standard 208V 230V and 480V drives up to Enclosed Style Enclosed drive B2 1 RO 1 RO NO 1 therm B5 RO B8 1 ext 24 Vdc EXT 24 Vdc Pt100 B9 1 RO NO 5 DI 42 240 Vac input 4 1 Al mA isolated 2 AO mA isolated 1 ext 24 Vdc EXT 24 VB Varnished boards Enclosed Options Type K1 Door mounted speed potentiometer Control K2 Door mounted speed potentiometer with HOA selector Control switch K3 3 15 psig follower Control K4 HAND OFF AUTO switch 22 mm Control K5 ANUAL AUTO reference switch 22 mm Control K6 START STOP pushbuttons 22 mm Control KF Bypass test switch for RA and RB Addl bypass KO Standard elapsed time meter Control L1 Power RUN and fault pilot lights Light L2 Bypass pilot lights for RA RB bypass options Addl bypass LE Red RUN light Light P1 nput circuit breaker Input P3 nput line fuses 200 kAIC Input P7 power surge protection Input P8 TVSS surge protective device Input PE Output contactor Output PF Output filter Output PG
228. W3 __ 5 TH Ra A M 91 w2 ws W1 gum 7 kasi c o WE Y 771 J n Y H7 gt lt H6 gt W4 H2 H1 gt Weight Voltage ly wi W wa w5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 D4 Lbs kg 480V 250 350 197 16 7 1 2 2 6 12 8 45 9 44 1 34 6 33 5 0 7 24 7 10 8 19 9 17 9 16 7 16 6 518 575V 200300 _ 500 425 30 67 325 1165 1121 879 850 17 627 275 506 455 423 421 235 Note 9000X FR12 is built of two FR10 modules Please refer to SPX9000 installation manual for mounting instructions Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 67 Adjustable Freguency Drives SVX9000 Drives 2 4 Approximate Dimensions in Inches mm 1 1 21 FR11 Freestanding Drive W5 ws gt IW6 W6 W6W7 W7W6 W6 W6 W4 e 6600666066 06000 N E 3 Dia 1 Dia 2 03 D5 A Ww2 gt W3 W3 W3 W3 W2 lt W1 gt lt D1 a mmm EN o z z 1 9 o H2 Operator Shown with NA Optional e amp
229. Works network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a FTT 10A Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system According to 15011898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay of nominal 5 nS m 120 ohms line termination resistors required for installation Adjustable Frequency Drives SPX9000 Drives DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The N2 fieldbus is available as a factory installed option and as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card
230. Y 20 o o Y Y 5 70 7 88 200 9 61 244 lt 55 14 Note Chokes are provided with all FR10 FR14 drives Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 73 7 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions Inches mm o s 0 0 0 0 24 et lol v LL uy 4 72 4 72 A 425 42 9 37 238 151 13 79 350 4 A oh 1 1 59 16 58 ids 15 15 08 421 2 64 354 118 1 xn 67 j 30 jr J5 po oen 3 3 UB 59 I mrt 15 92 927 lojo 581 A 590 140 150 lt 10 30 262 gt lt 10 83 275 CHK0261 24 6 4 72 a2 F 422 472 13 79 350 8 11 206 1 54 Ed 39 joh M 101 2 OR 59 15 lt 14 06 1 18 87 gt 12 56 357 22 y 80 1 20 318 po FSE o 3 59 prl 15 cag 10 1926 Y Y Y 4 25 5 90 39 75 19 150 7 10 9 06 230 Min 10 83 275 gt 08100007 2014 www eaton com
231. a two position switch labeled local remote is provided on the keypad to select speed reference from the speed potentiometer or a remote speed signal K2 Door Mounted Speed Potentiometer with HOA Selector Switch Provides the CPX9000 with the ability to start stop and adjust the speed reference from Contro door mounted control devices or remotely from customer supplied inputs In HAND position the drive will start and the speed is controlled by the door mounted speed potentiometer The drive will be disabled in the OFF position When AUTO is selected the drive run and speed control commands are via user supplied dry contact and 4 20 mA signal K3 3 15 psig Follower Provides a pneumatic transducer that converts a 3 15 psig pneumatic signal to either 0 8 Vdc or a 1 9 signal interface with the CPX9000 Contro The circuit board is mounted on the inside of the front enclosure panel and connects to the user s pneumatic control system via 6 ft 1 8m of flexible tubing and a 1 4 inch 6 4 mm brass tube union K4 HAND OFF AUTO Switch for Non Bypass Configurations Provides a three position selector switch that allows the user to select either a HAND or AUTO mode Contro of operation HAND mode is defaulted to keypad operation and AUTO mode is defaulted to control from an external terminal source These modes of operation can be configured via drive programming to allow for alternate combinations of start and speed sources Start and speed sources include
232. abetical order l SPX Open drives Extended 1 0 Card Options 2 RO Therm Horsepower Rating 4 low volt 5V 15V24V F07 3 4 125 125 pe Encoder high volt 15V 24V 001 1 150 150 7 Double Encoder FI5 1 1 2 250 250 A8 6 DI 1 DO 2 Al 002 _ 2 300 a 300 AE 3 DI Encoder 10 24V Out 15V 24V 2 DO pulse direction 003 _ 3 350 _ 350 B1 6 01 1 ext 24 Vdc EXT 24 Vdc 004 511 400 400 B2 1 RO NC NO 1 RO 1 therm CUL 7 B4 1 Al mA isolated 2 AO mA isolated 1 ext 24 Vdc EXT 24 005 5 opa 85 3 RO 006 7 1 2 1 gt B8 1 ext 24 Vdc EXT 24 3 Pt100 007 7 1 2 650 6 B9 1 RO NO 5 DI 42 240 Vac input 010 10 650 N 700 700 BB SPI absolute encoder 015 15 020 20 800 800 Communication Cards 025 25 900 900 Johnson Controls 2 5 PROFIBUS 09 030 30 10 1000 CI Modbus TCP C6 CANopen slave 040 40 H12 1200 CJ BACnet C7 DeviceNet 050 50 1350 CQ EtherNet IP C8 Modbus D9 type connector 060 60 15 1500 C2 Modbus D1 Adapter SPX only 075 75 H16 1600 C3 PROFIBUS DP D2 Adapter SPX only H20 2000 C4 LonWorks D3 RS 232 with D9 connection 100 100 AFD Software Series Board Modifications A Standard software Standard boards me 2 Conformal varnished coating Enclosure 9 Brake Ch 0 Chassis rake opper P ions 1 NEMA
233. acceleration deceleration Standard Linear or S curve accel decel Standard Jog at preset speed Standard Thread preset speeds 7 Automatic restart Selectable Coasting motor start Standard Coast or ramp stop selection Standard Elapsed time meter Optional Carrier frequency adjustment 1 16 kHz Standard Conditions for Application and Service Maximum operating ambient temperature 0 50 C up to FR9 0 40 FR10 and larger consult factory for 50 C rating above FR9 Storage temperature 40 to 60 Humidity maximum noncondensing 95 Altitude maximum without derate 3300 ft 1000m Line voltage variation 10 15 Line frequency variation 45 66 Hz Efficiency gt 95 Power factor displacement 0 99 Power factor apparent 0 99 V6 T2 244 Volume 6 Solid State Motor Control Two analog input configurable Voltage 0 10V gt 200 kohms w jumpers Current 0 4 20 mA 250 ohms Two digital output programmable Form C relays 250 Vac 30 Vdc 2 amp resistive One analog output programmable configurable w jumper 0 20 mA max 500 ohms 10 bits 2 I O Specifications for Control Communication Options Description Specification Analog voltage input 0 10V 2200 kilohms Analog current input 0 4 20 mA 250 ohms Digital input 24V 0 10V 1 218V gt 5 kilohms Auxiliary voltage 24V 20 max 50 mA Reference voltage 10V 396
234. actory promise delivery Consult sales office for availability Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 121 2 5 Product Selection E 230V Drives 208 240V NEMA Type 1 IP21 Drives Adjustable Frequency Drives SPX9000 Drives 5 9000 Open Drives Frame Size hp ly Current ly hp lj Current I Catalog Number e a FR4 3 4 3 7 1 4 8 SPXF07A1 2A1B1 eu 2 1 48 1 1 2 6 6 SPX001A1 2A1B1 1 1 2 6 6 2 78 SPXF15A1 2A1B1 2 7 8 3 11 SPX002A1 2A1B1 3 11 12 5 SPX003A1 2A1B1 FR5 12 5 5 17 5 SPX004A1 2A1B1 5 17 5 7 1 2 25 SPX005A1 2A1B1 7 1 2 25 10 31 SPX007A1 2A1B1 FR6 10 31 15 48 SPX010A1 2A1B1 15 48 20 61 SPX015A1 2A1B1 FR7 20 61 25 75 SPX020A1 2A1N1 25 75 30 88 SPX025A1 2A1N1 30 88 40 114 SPX030A1 2A1N1 FR8 40 114 50 140 SPX040A1 2A1N1 50 140 60 170 SPX050A1 2A1N1 60 170 75 205 SPX060A1 2A1N1 FR9 75 205 100 261 SPX075A1 2A1N1 100 261 SPX100A1 2A1N1 208 240V NEMA Type 12 IP54 Drives Frame Size hp In Current ly hp 14 Current I Catalog Number FRA 3 4 3 7 1 4 8 SPXF07A2 2A1B1 1 4 8 1 1 2 6 6 SPX001A2 2A1B1 1 1 2 6 6 2 7 8 SPXF15A2 2A1B1 2 7 8 3 1 SPX002A2 2A1B1 3 1 12 5 SPX003A2 2A1B1 FR5 12 5 5 17 5 SPX004A2 2A1B1 5 17 5 1 1 2 25 SPX005A2 2A1B1 7 1 2 25 10 31 SPX007A2 2A1B1 FR6 10 31 15 48 SPX010A2 2A1B1 15 48 20 61 SPX015A2 2A1B1 FRZ 20
235. ad Thermistor input Note Some horsepower units include dynamic braking chopper as standard refer to individual drive sections CA08100007E May 2014 www eaton com Adjustable Frequency Drives SVX9000 Drives 2 4 Wiring Diagrams A9 Board Control Wiring SVX9000 Pump Panel Bypass Power Wiring Incoming Power Basic I O 10Vref 1 Tt L1 L2 L3 Board A9 9 a f Input Reference Voltage Bypass GND 3 3 2 5 Circuit Al2 4 Input Reference 44 Breaker 2 5 Current 24Vout Control Voltage Output 1 p GND DIN1 Optional Fuse 4 DIN2 DIN3 GND 24Vout 11012 13 p GND 13 W DIN4 DIN5 5 DIN6 B AN g e sN To Drive Input To Drive Output AO1 0 4 20 mA AD A A 1 RL lt 500 W Output Bypass DO1 V lt 48V Contactor Contactor g koma Indicates Connections for Inverted Signals A2 Board Control Wiring Overload Weed ee Basic Relay Board A2 RO1A 21 1 V T2 U T1 o WI T3 um RO1 2 22 1 R RO1 3 23 7 AC DC RO2 1 24 Current Voltage SVX9000 Pump Panel Disconnect Power Wiring NG Switching RO2 2 25
236. address of the board is configurable by Static BOOTP and DHCP methods 2 V6 T2 205 2 7 Adjustable Freguency Drives 9000 Drives Control Communication Option Descriptions Available Control Communications Options Option Description Option Type K1 Door Mounted Speed Potentiometer Provides the drive with the ability to adjust the frequency reference using a door mounted potentiometer This option uses the Control 10 Vdc reference to generate 0 10V signal at the analog voltage input signal terminal When the bypass option is added the speed is controlled when the switch is in the HAND position Without the bypass option a two position switch labeled local remote is provided on the keypad to select speed reference from the speed potentiometer or a remote speed signal K2 Door Mounted Speed Potentiometer with HOA Selector Switch Provides the drive with the ability to start stop and adjust the speed reference from door Contro mounted control devices or remotely from customer supplied inputs In HAND position the drive will start and the speed is controlled by the door mounted speed potentiometer The drive will be disabled in the OFF position When AUTO is selected the drive run and speed control commands are via user supplied dry contact and 4 20 mA signal K3 3 15 psig Follower Provides a pneumatic transducer which converts a 3 15 psig pneumatic signal to either 0 8 or a 1 9
237. ain fan DC fan main 1 01061 01061 Other Mounting kit fixing kit 1 FR00050 FR00050 Mounting kit fixing kit N12 O 1 FR00081 FR00081 Control cover plastic N1 1 FR05011 FR05011 Notes Only for NEMA Type 12 54 Type drives Factory recommended spare parts G Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 5 V6 T2 135 2 5 Adjustable Freguency Drives 5 9000 Drives FR6 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 controlfan 1 PP01049 PP01049 Control module SPX control module 1 50000000000 50000000000 50000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power board 1 VB00316 0048 2 VB00416 0038 5 VB00404 0004 6 1 VB00316 0061 2 VB00416 0045 5 VB00404 0005 6 1 00416 0061 5 00404 0007 6 1 00404 0010 6 1 00404 0013 6 1 00404 0018 6 1 VB00404 0022 6 1 00404 0027 6 1 00404 0034 6 DC section Bus capacitor 2 S00930 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main fan 2 DC f
238. ammable Analog inputs Conformal coated boards 4 20mA Eatons Electrical Services amp 0 10V Systems national network One output analog or digital Onerelay output e RS 485 interface DC1 Series Interface of AF drive specialists Terminal Signal Factory Preset Description 1 24 Control voltage for 011 014 Maximum load 100 mA Reference potential V 2 DH Digital Input 1 Start Enable FWD 8 to 30V High R gt 6 3 012 Digital Input 2 Start Enable REV 8 to 30V High R gt 6 4 Digital Input 3 Fixed frequency FF1 Digital 8 30V high AD Analog Input 2 Fixed frequency FF1 Analog 0 to 10V gt 72 0 4 20 mA 500 0 Can be switched with parameter P16 5 10 Reference voltage Output 10V Maximum load 10 mA Reference potential 6 Analog Input 1 Frequency reference value Analog 0 to 10V R gt 72 fixed frequency 0 4 20 mA 500 0 Can be switched with parameter P16 DI4 Digital Input 5 Frequency reference value Digital 8 30V high fixed frequency 7 ov Reference potential OV connection terminal 9 8 A01 Analog Output 1 Output frequency Analog 0 to 10V maximum 4 20 mA Can be switched with parameter P 25 D01 Digital Output 1 Output frequency Digital 8 to 24V 9 0 Reference potential QV connection terminal 7 10 K13 Relay 1 normally open contact Active RUN Ma
239. an main 1 PP01062 PP01062 Other Mounting kit fixing kit 1 FR00060 FR00060 FR00060 Mounting kit fixing kit N12 O 1 FR00082 FR00082 FR00082 Control cover plastic N1 1 FR06011 FR06011 FR06011 FR7 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 PP01049 PP01049 01049 Control module SPX control module 1 50000000000 50000000000 50000000000 Standard slot 1 0 1 9 9 9 Standard slot 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power board 1 VB00319 0075 2 VB00619 0072 5 VB00419 0041 6 1 00319 0088 2 00619 0087 5 00419 0052 6 1 VB00319 0114 2 VB00619 0105 5 DC section Bus capacitor 2 01041 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main fan DC fan main 1 PP01063 PP01063 PP01063 Other Mounting kit fixing kit 1 FRO7071 FRO7071 FRO7071 Mounting kit fixing kit N12 O 1 FRO7072 FRO7072 FRO7072 Control cover plastic N1 1 FR07011 FRO7011 FRO7011 Notes Only for NEMA Type 12 IP54 Type drives Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 136 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives
240. an wave form to the motor EMI RFI filters standard on all drives meets EMC Category 2 for commercial applications Real time clock supports calendaring and PLC functionality Graphic LCD display and keypad supports simple menu navigation as well as diagnostics and troubleshooting e HAND OFF AUTO and drive bypass selector on keypad simplifies control e Standard 1 6DI 2 2 Form RO NO NC 1 Form A RO NO supports requirements for most installations Adjustable Frequency Drives Contents Description H Max Drives Catalog Number Selection Product Selection Accessories Replacement Parts Technical Data and Specifications Wiring Diagram Dimensions H Max IntelliPass and IntelliDisconnect Drives Onboard RS 485 Modbus 2 BACnet meets needs of most communication requirements Onboard Ethernet BACnet Modbus TCP meets needs of most communication requirements Two expansion slots intended to support additional I O or communication protocols as necessary Quick disconnect terminals for I O connections supports fast easy installation Software e Active energy control minimizes energy losses in your motor resulting in industry leading energy efficiency for your application Quick Start Wizard upon initial power up supports fast easy installation
241. ard Full torque control at all speeds including zero Torque accuracy lt 2 lt 5 down to zero speed e Starting torque gt 200 depending on motor and drive sizing Integrated datalogger for system analysis Fast multiple drive monitoring with PC e Full capability for master slave configurations e High speed bus 12 Mbit s for fast inter drive communication High speed applications up to 7200 Hz possible Robust design proven 500 000 hours MTBF e Integrated 3 line reactors standard on drives from FR4 through FR9 e Line reactor is included but is separated from chassis EMI RFI Filters H standard up to 200 hp 480V 100 hp lh 230V Simplified operating menu allows for typical programming changes while programming mode provides control of everything Quick Start Wizard built into the programming of the drive ensures a smooth start up Keypad can display up to three monitored parameters simultaneously LOCAL REMOTE operation from keypad Copy paste function allows transfer of parameter settings from one drive to the next Standard NEMA Type 12 IP54 keypad on all drives Hand held auxiliary 240 power supply allows programming monitoring of control module without applying full power to the drive The SPX can be flexibly adapted to a variety of needs using our pre installed Seven in One precision application programs consisting of Basic Standard Local remote Multi st
242. ard Drive overload protection Standard Discrete outputs Motor overload protection Standard Fault alarm Standard Programmer software Optional Drive running Standard Local remote keypad Standard Drive at set speed Programmable Keypad lockout Standard Optional parameters 14 Fault alarm output Standard Dry contacts 2 Form C contacts available Built in diagnostics Standard Additional discrete outputs Optiona Surge protective device Optional Communications RS 232 Standard RS 422 485 Optiona DeviceNet Optiona Modbus RTU Optiona CANopen slave Optiona PROFIBUS DP Optiona LonWorks Optional Johnson Controls Metasys 2 Optiona EtherNet IP Modbus TCP Optiona BACnet Optiona Note Volume 6 Solid State Motor Control The EMI filter is optional FR10 and larger CA08100007E May 2014 www eaton com V6 T2 243 28 9000 Drives 9000 Drives Description Specification Performance Features Adjustable Freguency Drives Standard Specifications Description Specification Six digital input programmable 24V 0 10V 1 218VR gt 5 kohms Sensorless vector control Standard Volts hertz control Standard IR and slip compensation Standard Electronic reversing Standard Dynamic braking Optional DC braking Standard PID set point controller Programmable Critical speed lockout Standard Current torque limit Standard Adjustable
243. are tool Volume 6 Solid State Motor Control 08100007 2014 www eaton com BACnet Network Communications The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It includes a 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Analog Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 127 EtherNet IP Network Communications The EtherNet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters CIP is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable by Static BOOTP and DHCP methods 2 4 V6 T2 83 2 4 Adjustable Freguency Drives 5 9000 Drives Control Communication Option Descriptions For availability see Product Selection for base drive voltage required Available Control Communications Options Option Description Option Type K1 Door Mounted Speed Potentiometer Provides the
244. armonic calculations are taken An oscilloscope can make all measurements at the PCC or POA do an on site harmonic evaluation V6 T2 224 Volume 6 Solid State Motor Control Harmonic Reduction Methods to Meet IEEE 519 1 Line Reactor A line reactor is a three phase series inductance on the line side of an AFD If a line reactor is applied on all AFDs itis possible to meet IEEE guidelines where 10 25 of system loads are AFDs depending on the stiffness of the line and the value of line reactance Line reactors are available in various values of impedance most typically 1 1 5 3 and 5 Line Reactor NMM Nn I Nn TT AFD Advantages e Low cost e Can provide moderate reduction in voltage and current harmonics e Available in various values of impedance e Provides increased input protection for AFD and its semiconductors from line transients CA08100007E May 2014 www eaton com Disadvantages not reduce harmonic levels to below IEEE 519 1992 guidelines e Voltage drop due to IR loss 2 12 Pulse Converters A 12 pulse converter incorporates two separate AFD input semiconductor bridges which are fed from 30 phase shifted power sources with identical impedance The sources may be two isolation transformers where one is a delta wye design which Adjustable Frequency Drives 9000 Drives the second a delta delta design which does not phase shift
245. at 230 1 5 250 hp at 480 Note Available in NEMA 1 or NEMA 12 designs IntelliPass IntelliDisconnect Drives 1 30 hp at 208 Vac 1 30 hp at 230 Vac e 1 75 hp at 480 Vac Note Available in NEMA 1 NEMA 12 or NEMA 3R enclosures Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 6 H Max Series Drives Contents Description H Max Series Drives H Max Drives H Max IntelliPass and IntelliDisconnect Drives Application Description The H Max Series drive was designed specifically for HVAC pump and fluid control applications It is intended to be used on variable torque loads with the intent of moving air or liquids With this in mind the H Max drive has onboard pre programmed to meet the common needs for these applications The H Max drive supports items such as standard speed control PID functionality as well as multi motor applications The drive easily supports interlock second motor parameter set as well as fire mode functionality Page V6 T2 162 V6 T2 171 Key Feature Active Energy Control Algorithm Eaton s H Max Series drives have been designed to provide industry leading energy saving solutions Not only is the drive ultra efficient the drive seeks the most efficient operating point of the motor minimizing energy loss in the windings per the given load requirements This is an Eaton protected control algorithm e
246. at 40 C Horsepower 230 Vac 50 Hz Amps Load Amps at 50 C Number 4 37 0 75 0 55 3 2 2 6 HMX32AG3D721 N 4 8 1 0 75 4 2 3 7 HMX32AG4D821 N 6 6 1 5 1 1 6 6 4 8 HMX32AG6D621 N 8 2 15 6 8 6 6 HMX32AG8D021 N 1 3 22 96 8 HMX32AG01121 N 12 5 4 3 N A 11 HMX32AG01221 N 5 18 5 4 15 2 12 5 HMX32AG01821 N 24 75 5 5 22 18 HMX32AG02421 N 31 10 75 28 24 HMX32AG03121 N 6 48 15 11 42 31 HMX32AG04821 N 62 20 15 54 48 HMX32AG06221 N 7 75 25 18 5 68 62 HMX32AG07521 N 88 30 22 80 75 HMX32AG08821 N 105 40 30 104 88 HMX32AG10521 N 8 140 50 37 130 105 HMX32AG14021 N 170 60 45 154 140 HMX32AG17021 N 205 75 55 192 170 HMX32AG20521 N 9 261 100 75 248 205 HMX32AG26121 N 310 125 90 N A 261 HMX32AG31021 N Nema Type 1 NEMA Type 12 1 54 FS Drive Output Current Assigned Motor Ratings Frame Low Overload Full Drive kW 230 Vac Low Overload Full Catalog Size Load Amps at 40 Horsepower 230 Vac 50 Hz NEC Amps o Load Amps at 50 C Number 4 37 0 75 0 55 3 2 2 6 HMX32AG3D722 N 4 8 1 0 75 4 2 3 7 HMX32AG4D822 N 6 6 1 5 1 1 6 6 4 8 HMX32AG6D622 N 8 2 1 5 6 8 6 6 HMX32AG8D022 N 11 3 2 2 9 6 8 HMX32AG01122 N 12 5 4 3 N A 11 HMX32AG01222 N 5 18 5 4 15 2 12 HMX32AG01822 N 24 75 5 5 22 18 HMX32AG02422 N 31 10 75 28 24 HMX32AG03122 N 6 48 15 11 42 31 HMX32AG04822 N 62 20 15 54 48 HMX32AG06222 N 7 75 25 18 5 68 62 HMX32AG07522 N 88 30 22 80 75 HMX32AG08822 N 105 40 30 104 88 HMX32AG10522 N 8 140 50 37 130 105 HMX32AG14022 N 170 60 45 154 140 HMX32AG17022 N 205 75 55 1
247. ations Johnson Controls Metasys N2 H Max Series provides communication between the drive and a Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system N2 can be selected and programmed by the drive keypad Adjustable Frequency Drives BACnet H Max Series provides communication to BACnet networks Data transfer is master slave token passing MS TP RS 485 BACnet IP 100Base T interface Modbus TCP Ethernet based protocol H Max Series 0ption Board Kits Available for Slots D and E The H Max Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of two option boards Option Boards Mounted in Slots D and E H Max Series Drives Modbus RTU H Max Series provides communication to Modbus RTU RS 485 as a slave Modbus network Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 The H Max Series factory installed standard board configuration includes an I O board and a relay output board Option Kit Option Kit Description Catalog Number 6 x DI DO each digital input can be individually programmed as digital output 10 1 Form C NO NC 180 Form A 1 thermistor
248. ave input current and low harmonics will meet the requirements of IEEE 519 1992 under all practical operating conditions The comparisons with six pulse passive filter and 12 pulse systems are shown on Pages V6 T2 190 V6 T2 192 and below Dynamic Braking Transistor Bus Capacitors 100 hp 480V Drive with 18 Pulse Rectifiers Current Amps 200 100 100 200 V6 T2 194 Volume 6 Solid State Motor Control Time Output Transistors IGBT Section 100 hp 480V Drive with 18 Pulse Rectifiers 18 Pulse Clean Power Current harmonics 11 100 1 0 2490 lig 1 00 ls 0 16 lg 0 1096 Ing 0 01 0 03 17 0 86 log 0 01 Power 100 hp H 5 9 Amps Advantages Disadvantages e Effectively guarantees compliance with IEEE 519 1992 e Provides increased input protection for AFD and its semiconductors from line transients e Up to 4 times the harmonic reduction of 12 pulse methods Smaller transformer than isolation transformer used in 12 pulse converter e Minimizes ripple current in capacitors doubling expected capacitor life CA08100007E May 2014 www eaton com Notas cost effective as some other methods at small 50 horsepower Adjustable Freguency Drives 2 7 9000 Drives Standards Features and Benefits Certifications New CFX9000 Integrated
249. based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 4 V6 T2 49 2 4 Adjustable Freguency Drives SVX9000 Drives FR6 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 controlfan 1 PP01049 PP01049 Control module SVX control module 1 CSBS0000000000 CSBS0000000000 CSBS0000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power board 1 VB00316 0048 2 VB00416 0038 5 VB00404 0004 6 1 VB00316 0061 2 VB00416 0045 5 VB00404 0005 6 1 00416 0061 5 00404 0007 6 1 00404 0010 6 1 00404 0013 6 1 00404 0018 6 1 VB00404 0022 6 1 00404 0027 6 1 00404 0034 6 DC section Bus capacitor 2 S00930 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main fan 2 DC fan main 1 PP01062 PP01062 Other Mounting kit fixing kit 1 FR00060 FR00060 FR00060 Mounting kit fixing kit N12 O 1 FR00082 FR00082 FR00082 Control cover plastic N1 1 FR06011 FR06011 FR06011 FR7 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA
250. ble Freguency Drives LCX9000 Drives Options 9000X Series Option Board Kits The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes A9 I O board and 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard Cards 2 RO NC NO B OPTA2 6 DI 1 DO 2 Al TAO 1 10 ref A OPTA9 2 ext 24 Vdc EXT 24 Extended Cards 2 RO therm B OPTA3 A3 nm Encoder low Volt 5V 15V 24V C 4 4 high Volt 15V 24V C OPTA5 A5 Dual encoder 15V 24V C OPTA7 7 601 100 2 Al 1 AO A OPTA8 A8 3 DI encoder 10 24 out 15V 24V C OPTAE AE 2 DO pulse direction SPX only 6 DI 1 ext 24 Vdc EXT 24 B C D E
251. ble Freguency Drives 2 5 SPX9000 Drives Approximate Dimensions in Inches mm FR10 Open Chassis lt H3 gt H5 gt Y pa a W3 __ 5 TH Ra A M 91 w2 ws W1 gum 7 kasi c o WE Y 771 J n Y H7 gt lt H6 gt W4 H2 H1 gt Weight Voltage hp ly wi W W3 W4 w5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 D4 Lbs kg 480V 250 350 197 167 1 2 2 6 12 8 45 9 44 1 34 6 33 5 0 7 24 7 10 8 19 9 17 9 16 7 16 6 518 575V 200 300 500 425 30 67 325 1165 1121 879 850 17 627 275 506 455 423 421 235 Note SPX9000X FR12 is built of two FR10 modules Please refer to SPX9000 installation manual for mounting instructions Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 153 2 5 Adjustable Frequency Drives SPX9000 Drives Approximate Dimensions in Inches mm
252. cal Data and Specifications 9000 Drives Description Specification Input Ratings Description Specification Control Connections Input voltage Vin 10 15 Input frequency fin 50 60 Hz variation up to 45 66 Hz Connection to power Once per minute or less typical operation High withstand rating 100 Output Ratings Output voltage 0 to Vin Continuous output current Ih rated 100 at 122 F 50 C FR9 and below li rated 100 at 104 F 40 C FR9 and below 16 11 100 at 104 F 40 C FR10 and above A 5 alog input voltage 0 to 10V R 200 kohms 10 to 10V joystick control resolution 0 1 accuracy 1 Analog input current 0 4 to 20 mA 250 ohms differential Digital inputs 6 Positive or negative logic 18 to 30 Vdc Auxiliary voltage 24V 31596 max 250 mA Output reference voltage 10V 4396 max load 10 mA Analog output 0 4 to 20 mA max 500 ohms resolution 10 bit Accuracy 2 Digital outputs Open collector output 50 mA 48V Overload current 16 1 15096 lu 11096 for 1 min Output frequency 010 320 Hz Frequency resolution 0 01 Hz Initial output current ly 250 for 2 seconds Control Characteristics Control method Frequency control V f Open loop sensorless vector control Closed loop frequency control Closed loop vector control Relay output
253. cal speed lockout Standard Current torque limit Standard Adjustable acceleration deceleration Standard Linear or S curve accel decel Standard Jog at preset speed Standard Thread preset speeds 7 Standard 15 Optional Automatic restart Selectable Coasting motor start Standard Coast or ramp stop selection Standard Elapsed time meter Optional Carrier frequency adjustment 1 16 kHz Standard Conditions for Application and Service Operating ambient temperature 010 40 Storage temperature 40 to 60 Humidity maximum non condensing 95 Altitude maximum without derate 3300 ft 1000m Line voltage variation 10 15 Line frequency variation 45 66 Hz Efficiency gt 96 Power factor displacement gt 0 94 Volume 6 Solid State Motor Control Two analog input configurable w jumpers Voltage 0 10V R gt 200 kohms Current 0 4 20 mA R 250 ohms Two digital output programmable Form relays 250 30 Vdc 2 amp resistive One analog output programmable configurable w jumper 0 20 mA max 500 ohms 10 bits 2 One digital output programmable Open collector 48 Vdc 50 mA I O Specifications for Control Communication Options Description Analog voltage input Specification 0 10V 2200 kohms Analog current input 0 4 20 mA 250 ohms Digital input 24V 0 10V 1 218V R gt 5 kohms Auxiliary voltage 24V 420
254. ce module DX NET ETHERNET 2 EtherCAT plug in interface module DX NET ETHERCAT 2 PROFINET plug in interface module DX NET PROFINET 2 Modbus TCP plug in interface module DX NET MODBUSTCP 2 BACnet plug in interface module DX NET BACNETIP 2 Encoder Feedback Plug In Option Module and Miscellaneous Cards Description Local control test option card Catalog Number DXC EXT LOCSIM HVACO drive running and tripped relay output card DXC EXT 2R01A0 Relay output option module DXA EXT 3RO Dual relay output card DXC EXT 2R0 110V logic input card DXC EXT 10110 230V logic input card DXC EXT 10230 Encoder feedback plug in option module D DXA EXT ENCOD V6 T2 14 Volume 6 Solid State Motor Control multi language IP54 Extension Cables and Data Cable Splitter Description RJ45 communication cable w terminating resistor Catalog Number DX CBL TERM RS 485 data cable RJ45 0 5m DX CBL RJ45 0M5 RS 485 data cable RJ45 1 0m DX CBL RJ45 1M0 RS 485 data cable RJ45 3 0m DX CBL RJ45 3M0 RS 485 three way data cable splitter RJ45 DX SPL RJ45 3SL RS 485 data cable splitter RJ45 1 connector to 2 socket DX SPL RJ45 2SL1PL SmartWire Modules Description SmartWire DT interface for DC1 IP20 Catalog Number DX NET SWD3 SmartWire DT interface for DA1 20 DX NET SWD1 Note Only applicable for DA1
255. cludes a 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Analog Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 127 EtherNet IP Network Communications The EtherNet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters CIP is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable by Static BOOTP and DHCP methods CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 SVX9000 Drives Control Panel Options Factory Options Factory Installed Field Installed NEMA Type 1 IP21 Description Option Code Catalog Number Local Remote Keypad SVX9000 Control Panel This option is standard on all drives and A KEYPAD LOC REM consists of an RS 232 connection backlit alphanumeric LCD display with nine indicators for the RUN status and two indicators for the control source The nine pushbuttons on the panel are used for panel programming and monitoring of all SVX9000 parameters The panel is detachable and isolated from the input line p
256. ct enclosed options Add the codes as suffixes to the base catalog number in alphabetical and numeric order 2 8 V6 T2 229 2 8 Adjustable Freguency Drives 9000 Drives CPx9000 Drive 1 9000 Base Drive NEMA 12 Filtered Enclosure Current Chassis Base Catalog Size hp O A Frame Number Low Overload Drive 7 25 75 FRZ CPX02562AA 30 88 FR7 CPX03062AA 40 114 FR7 CPX04062AA 50 140 FR8 CPX05062AA 60 170 FR8 CPX06062AA 75 205 FR8 CPX07562AA 8 100 300 FRO CPX10062AA 9 125 340 FR8T CPX12562AA 150 410 FR8T CPX15052AA 10 200 522 FROT CPX20062AA High Overload Drive 7 25 75 FR7 CPX02562DA 30 88 FR7 CPX03062DA 40 114 FR8 CPX04062DA 50 140 FR8 CPX05062DA 60 170 FR8 CPX06062DA 8 75 205 FR9 CPX07562DA 9 100 300 FR8T CPX10062DA 125 340 FR8T CPX12562DA 10 150 410 FROT CPX15062DA 200 522 FROT CPX20062DA CPX9000 Base Drive Enclosure Current Chassis Base Catalog Size hp O A Frame Number Low Overload Drive 7 25 75 FR7 CPX02532AA 30 88 FR7 CPX03032AA 40 114 FR7 CPX04032AA 50 140 FR8 CPX05032AA 60 170 FR8 CPX06032AA 75 205 FR8 CPX07532AA 8 100 300 FRO CPX10032AA 9 125 340 FR8T CPX12532AA High Overload Drive 7 25 75 FR7 CPX02532DA 30 88 FR7 CPX03032DA 40 114 FR8 CPX04032DA 50 140 FR8 CPX05032DA 60 170 FR8 CPX06032DA 8 75 205 FR9 CPX07532DA 9 100 300 FR8T CPX10032D
257. ctor bypass option provides a means of bypassing the CFX9000 Bypass allowing the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of the load to across the line operation after a drive trip This option consists of an input a fused control power transformer and a full voltage bypass starter with a door mounted IOB selector switch IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 211 Door mounted pilot lights are provided that indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position RG Reduced Voltage Starter for Bypass Used in conjunction with bypass option RB RC or RD This option adds IT Series reduced voltage soft starter to bypass Bypass assembly for soft starting in bypass mode S4 Floor Stand 6 in Raises F box off the ground 6 in 152 4 mm Recommended when box is not installed on an appropriate concrete pad Enclosure S5 Floor Stand 22 in Converts a Size B or C normally wall mounted enclosure to a floor standing enclosure with a height of 22 in 558 8 mm Enclosure S6 Floor Stand
258. cy Drives 2 3 M Max Series Adjustable Frequency AC Drives M Max Series Drives for Machinery Applications Product Description Eaton s M Max Series Sensorless Vector Adjustable Frequency AC Drives are the next generation of drives specifically engineered for today s machinery applications These micro processor based drives have standard features that can be programmed to tailor the drive s performance to suit a wide variety of application requirements The M Max product line uses a 32 bit microprocessor and insulated gate bipolar transistors IGBTs that provide quiet motor operation high motor efficiency and smooth low speed performance The size and simplicity of the M Max make it ideal for hassle free installation Models rated at 575 volts three phase 50 60 Hz are available in sizes ranging from 1 to 7 1 2 hp Models rated at 480 volts three phase 50 60 Hz are available in sizes ranging from 1 2 to 25 hp Models rated at 240 volts single or three phase 50 60 Hz are available in sizes ranging from 1 4 to 15 hp Models rated at 115 volts single phase 50 60 Hz are available in the 1 4 to 1 1 2 hp size range The standard drive includes a digital display and operating and programming keys on a visually appealing efficient application programming interface The display provides drive monitoring as well as adjustment and diagnostic information The keys are used for digital adjustment an
259. d as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks using Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable over Ethernet using a supplied software tool Volume 6 Solid State Motor Control 08100007 2014 www eaton com BACnet Network Communications The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It includes 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Analog Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 to 127 Ethernet IP Network Communications The Ethernet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters CIP is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP
260. d NEMA Type 12 IP54 Drives SVX F07 14 A A Build Alphabetically and Numerically NG Enclosed Options Type Product Family Door mounted speed potentiometer Control K2 Door mounted speed potentiometer with Control Enclosed drives selector switch K4 HAND OFF AUTO switch 22 mm Control K5 MANUAL AUTO ref switch 22 mm Control Horsepower Rating START STOP pushbuttons 22 mm Control F07 3 4 hp 025 25 hp 250 250 hp KB 115V control transformer 500 Control 001 1 hp 030 30 hp 300 300 hp KF Bypass test switch for RA and RB Addl bypass F15 1 1 2hp 040 40 hp 350 350 hp Standard elapsed time meter Control 002 2 hp 050 50 hp 400 400 hp L1 POWER ON RUN and FAULT pilot lights Light 003 3 hp 060 60 hp 500 500 hp 12 Bypass pilot lights for RA RB bypass options Addl bypass 005 5 hp 075 75 550 550 LA Green RUN light 22 mm Light 007 7 2hp 100 1008 600 600 hp LD Green STOP light 22 mm Light 010 10 125 125 650 650 LE Red RUN light Light 5 15 150 150 700 700 hp LF Red STOP light 22 mm Light 020 20hp 200 200hp 00 800 hp LJ White POWER ON light 22 mm Light LU Misc light 22 mm Light P1
261. d programming of the drive as well as for operator control Separate terminal blocks for control and power wiring are provided for customer connections Volume 6 Solid State Motor Control Contents Description Page M Max Series Adjustable Frequency AC Drive Catalog Number Selection Product Selection Accessories Technical Data and Specifications Dimensions Features Ease of use preset application macros startup wizard diagnostic capabilities Compact space saving design Rugged and reliable 150 torque for one minute 50C rated conformal coated boards e DIN and screw mountable Side by side installation Industry leading efficiency delivers energy savings to the customer Integrated 5 DC choke FS4 and FS5 Standards and Certifications Product Complies with EN61800 3 2004 Safety 61800 5 1 EN60204 1 UL cUL EC RoHS compliant CEG QD Rs CA08100007E May 2014 www eaton com V6 T2 24 V6 T2 25 V6 T2 26 V6 T2 27 V6 T2 29 Integrated filters make the unit suitable for commercial and industrial networks P21 as standard option for 1 FS4 and FS5 P20 as standard option IP21 NEMA 1 FS1 FS3 e Brake chopper as standard in three phase applications of frames 2 FS2 and larger Temperature controlled fan
262. dard Additional discrete outputs Optiona Built in diagnostics Standard Communications 5 232 Standard RS 422 485 Optiona DeviceNet M Optiona odbus RTU Optiona slave Optiona PROFIBUS DP Optiona Lonworks Optiona Johnson Controls Metasys M N2 Optiona EtherNet IP Optiona Modbus TCP Optiona BACnet Optiona Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 109 2 4 5 9000 Drives 9000X Pump Panels continued Description NEMA Type 12 1P54 or NEMA Type 3R Specification Performance Features Adjustable Frequency Drives Standard Specifications Description Specification Six digital input 24V 0 10V 1 218VR gt 5 kohms programmable Sensorless vector control Standard Volts hertz control Standard IR and slip compensation Standard Electronic reversing Standard Dynamic braking Optional DC braking Standard PID setpoint controller Programmable Critical speed lockout Standard Current torque limit Standard Adjustable acceleration deceleration Standard Linear or curve accel decel Standard Jog at preset speed Standard Thread preset speeds 7 Standard 15 Optional Automatic restart Selectable Coasting motor start Standard Coast or ramp stop selection Standard Elapsed time meter Optional Carrier frequency adjustment 1 16 kHz Standard Conditions for Application and Service
263. digital output 10 1 1 0 Form NO NC 180 Form A 1 thermistor 10 2 1xAl 2 x AO isolated XMX I0 B4 A Form N0 10 5 1RO Form A 501 42 240 Vac input 10 9 1xA0 1 x DO 1 x RO XMX I0 BF A LonWorks 0 4 Kit consists drive cover plugs NEMA Type 12 1P54 Cover Option Kit Option Kit Description Catalog Number FS4 branded 12 1 54 cover with gasket plastic plug fans Eaton logos FS4 N12KIT FS5 branded 12 1 54 cover with gasket plastic plug fans Eaton logos FS5 N12KIT FS6 branded 12 1 54 cover with gasket plastic plug fans Eaton logos FS6 N12KIT Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 6 Series Drives Accessories Replacement Parts Flange Kits m a Control Board Keypad The flange kit is used when the power section heat sink is h hth k lat Catalog mounted through the back panel ofan enclosure Description Number Flange Kit NEMA Type 12 IP54 Series graphic bypass KeypadbypassH0A Includes flange mounting brackets NEMA Type 12 fan H Max Series graphic back KeypadbackHOA components air shroud screws and plugs PC Cable Frames FS4 FS7 Catalog Catalog Description Number Description Number Remote download USB to RJ 45 cable with REM USB
264. drive hp rating For example a 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable V6 T2 206 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 9000 Drives Available Control Communications Options continued 2 7 Option Description Option Type RA Manual HOA Bypass Controller The manual HAND OFF AUTO HOA three contactor bypass option provides a means of bypassing the CFX9000 allowing the Bypass AC motor to be operated at full speed directly from the AC supply line This option consists of an input HMCP a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in the inverter mode IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 211 RB Manual IOB Bypass Controller The manual INVERTER OFF BYPASS IOB three contactor bypass option provides a means of bypassing the CFX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line This option consists of an input HMCP a fused cont
265. ds under IEEE 519 1992 guidelines than allowable using line reactors or DC chokes A harmonic analysis is required to guarantee compliance with guidelines Basic 12 Pulse Rectifier with Phase Shifting Transformer 12 Pulse 12 Pulse Diode Inverter Section Phase Shifting Bridge Rectifier Transformer 1 Converter Section 1 1 LDC uA ee 1 ia L2A L3A 4 12 Pulse Bridge Rectifier Converter Section Bus Capacitors Dynamic Braking Transistor Output Transistors IGBT Section 100 hp 480V Drive with 12 Pulse Rectifier 100 hp 480V Drive with 12 Pulse Rectifier 12 Pulse Circuit Current Amps Current harmonics 200 100 1 419 lg 0 0696 lg 1 25 l3 2 95 63 0 87 100 0 48 17 0 21 lg 0 73 Power 100 hp 0 H 20 Amps Advantages Disadvantages MR Reasonable cost although mpedance matching of significantly more than phase shifted sources is 200 reactors or chokes critical to performance Time Substantial reduction up to Transformers often require approx 8596 in voltage separate mounting or and current harmonics larger AFD enclosures Provides increased input May not reduce protection for AFD and its distribution harmonic levels semiconductors from line to below IEEE 519
266. e L2 npu V T2 Motor Single Phase not available Output ___ __ X h t cdd 1 43 W T3 N Slot A Default Signal Resistor H 1 10 Reference Output Analog Input Voltage Range 0 10 Vdc 2 can be programmed to current 4 20 mA Vin Analog Output Common Ground Analog Input Current Range 4 20 mA 4 Al 2 can be programmed to voltage 0 10 Vdc PI Setpoint or Feedback Factory 5 Al 2 Analog Input Common Jumper PI Setpoint or Feedback Test 6 24Vout Control Voltage Output 0 1A max 4 ON OFF 5485 7 GND I O Ground CURRENT 8 VOLTAGE AO1 CURRENT JH VOLTAGE Al2 8 DIN1 START STOP Contact closed start CURRENT E VOLTAGE AM 9 DIN2 External Fault Closed fault DIN3 Run Interlock Permissive IP Interlock Closed OK COM DIN1 DIN6 Common 24Vout Control Voltage Output 0 1A max GND Ground DIN4 Speed Select 0 100 Preset speed DIN5 Fire Mode Contact closed fire mode DING Force Bypass Contact closed bypass 17 DIN1 DIN6 Common Terminal Block Layout 418 AO 1 Output Frequency 0 20 mA 19 AO 1 Analog Output Common Ground Analog 30 24Vdcin Auxiliary Input Voltage 21 22 23 24 25 26 32 33 o o DATA RS 485DATA Programmable BACnet do RET bad Go RZ m B DATA 85 485 DATA Modbus FLN N2 NC COM NO NC COM NO COM NO 21 Relay Board 1 Slot B 12 13 18 19
267. e 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 09 LCX9000 Drives LCX9000 Liquid Cooled 540 675 Vdc Liquid Cooled Inverter Units continued Drives Drive Output Current Motor Output Power Power Loss Thermal Rated Cont Rated Cont Optimum Motor Optimum Motor c a T 1 A 1 A at ly 400V kW at ly 500V kW kW Chassis Catalog Number 650 591 433 355 450 8 5 0 6 9 1 CH62 LCX650A0 4A7N2 730 664 487 400 500 10 0 0 7 10 7 CH62 LCX730A0 4A7N2 820 745 547 450 560 12 5 0 8 13 3 CH63 LCX820A0 4A7N2 920 836 613 500 600 14 4 0 9 15 3 CH63 LCX920A0 4A7N2 1030 936 687 560 700 16 5 1 0 17 5 CH63 LCXH10A0 4A7N2 1150 1045 766 600 750 18 4 10 1 19 5 CH63 LCXH11A0 4A7N2 1370 1245 913 700 900 15 5 1 0 16 5 CH64 LCXH13A0 4A7N2 1640 1491 1093 900 1100 19 5 1 2 20 7 CH64 LCXH16A0 4A7N2 2060 1873 1373 1100 1400 26 5 1 5 28 0 CH64 LCXH20A0 4A7N2 2300 2091 1533 1250 1500 29 6 1 7 31 3 CH64 LCXH23A0 4A7N2 2470 2245 1647 1300 1600 36 0 2 0 38 0 2 CH64 LCXH24A0 4A7N2 2950 2681 1967 1550 1950 39 0 2 4 41 4 2 CH64 LCXH29A0 4A7N2 3710 3372 2473 1950 2450 48 0 2 7 50 7 2 CH64 LCXH37A0 4A7N2 4140 3763 2760 2150 2700 53 0 3 0 66 0 2 CH64 LCXH41A0 4A7N2 710 930 Liquid Cooled Inverter Unit Drive Output Current Motor Output Power Power Loss Thermal Rated Cont Rated Cont Opti
268. e 7 12 Adjustable with parameter 2 6 9 1 16 kHz default 10 kHz 1 10 kHz default 3 6 kHz Frequency reference Analog input Resolution 0 1 10 bit accuracy 1 V Hz Panel reference Resolution 0 01 Hz Field weakening point 30 320 Hz Acceleration time 0 3000 sec Deceleration time 0 3000 sec Braking torque DC brake 30 x T without brake option Ambient Conditions Ambient operating 14 F 10 C no frost to 122 F 50 C ly FR4 FR9 temperature 14 F 10 C no frost to 104 F 40 C ly FR10 and up 14 F 10 C no frost to 10491 40 C all frames Storage temperature 40 to 1589 40 to 70 C Relative humidity 0 to 95 RH noncondensing non corrosive no dripping water Air quality Chemical vapors IEC 721 3 3 unit in operation class 302 Mechanical particles IEC 721 3 3 unit in operation class 352 Altitude 100 load capacity no derating up to 3280 ft 1000m 1 derating for each 328 ft 100m above 3280 ft 1000m max 9842 ft 3000m Vibration EN 50178 EN 60068 2 6 5 to 50 Hz displacement amplitude 1 mm peak at 3 to 15 8 Hz max acceleration amplitude 1G at 15 8 to 150 Hz Shock EN 50178 EN 60068 2 27 UPS Drop test for applicable UPS weights Storage and shipping max 15G 11 ms in package Enclosure class NEMA 1 IP21 or NEMA 12 IP54 open chassis IP20 V6 T2 58 Volume 6 Solid State Motor
269. e Base Catalog Size hp Current A Size Number 2 Size Number 2 Low Overload Drive and Enclosure 0 1 1 2 33 4 SVXF1514BA 4 SVXF1524BA 2 43 SVX00214BA SVX00224BA 3 5 6 SVX00314BA SVX00324BA 5 7 6 SVX00514BA SVX00524BA 7 1 2 12 SVX00714BA SVX00724BA 10 16 5 SVX01014BA 5 SVX01024BA 15 23 SVX01514BA SVX01524BA 20 31 SVX02014BA SVX02024BA 1 25 38 6 SVX02514BA 6 SVX02524BA 30 46 SVX03014BA SVX03024BA 40 61 SVX04014BA SVX04024BA 2 50 72 7 SVX05014AA 7 SVX05024AA 60 87 SVX06014AA SVX06024AA 75 105 SVX07514AA SVX07524AA 3 100 140 8 SVX10014AA 8 SVX10024AA 4 125 170 8 SVX12514AA 8 SVX12524AA 150 205 SVX15014AA SVX15024AA 5 200 261 9 SVX20014AA 9 SVX20024AA 250 300 SVX25014AA SVX25024AA 6 899 300 385 0 SVX30014AA 10 SVX30064AA 350 460 SVX35014AA SVX35064AA 400 520 SVX40014AA SVX40064AA 8 999 500 590 1 SVX50014AA 11 SVX50064AA 550 650 SVX55014AA SVX55064AA 600 730 SVX60014AA SVX60064AA 650 820 2 SVX65014AA 12 SVX65064AA 700 920 SVX70014AA SVX70064AA 800 1030 SVX80014AA SVX80064AA Notes For brake chopper options see Page V6 T2 46 See enclosure dimensions starting on Page V6 T2 88 Includes drive local remote keypad and enclosure The smaller enclosure Size 6 accommodates only power options input disconnect P1 and input line fuses P3 Bypass and other options require Size 8 Adding any standard control option will not require the larger enclosure For other options consult factory The smaller enclosure Size 8 acc
270. e Number Size Number High Overload Drive and Enclosure A 3 4 4 SVXF0722EP 4 SVXF0732EP 1222 SVX00122EP 0 SVX00132EP 0 1200 SVXF1522EP SVXF1532EP 00 2 SVX00222EP 0 SVX00232EP 0 3 5 SVX00322EP 5 SVX00332EP 5 SVX00522EP 0 SVX00532EP 0 MARO SVX00722EP 0 SVX00732EP 10 6 SVX01022EP 6 SVX01032EP 180000 SVX01522EP 0 SVX01532EP 0 20 7 SVX02022DP 7 SVX02032DP 2 SVX02522DP SVX02532DP 0 3232 7 SVX03022DP 0 SVX03032DP 0 40 8 SVX04022DP 8 SVX04032DP 5 7 SVX05022DP 0 SVX05032DP 0 6 7 SVX06022DP SVX060322DP F 75 9 9 SVX07532DP 10 7 SVX10032DP Low Overload Drive and Enclosure 1 4 SVX00122BP 4 SVX00132BP 12000 SVXF1522BP 00 SVXF1532BP 0 2 SVX00222BP 0 SVX00232BP 0 8 SVX00322BP SVX00332BP 5 5 SVX00522BP 5 SVX00532BP TQ SVX00722BP SVX00732BP 0 SVX01022BP 0 SVX01032BP 0 15 6 SVX01522BP 6 SVX01532BP 2 7 SVX02022BP 0 SVX02032BP 25 7 SVX02522AP 7 SVX02532AP 80 SVX03022AP SVX03032AP 0 SVX04022AP 0 SVX04032AP 0 50 8 05022 8 SVX05032AP 6 SVX06022AP SVX06032AP nG SVX07522AP SVX07532AP F 100 9 9 SVX10032AP 125 SVX12532AP Notes Enclosure dimensions starting Page V6 T2 112 Includes drive local remote keypad and enclosure V6 T2 102 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4
271. e load to across the line operation after a drive trip This option consists of an input a fused control power transformer and a full voltage bypass starter with a door mounted IOB selector switch IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 245 mounted pilot lights are provided that indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position RG Reduced Voltage Starter for Bypass Used in conjunction with bypass option RA RB RC or RD This option adds reduced voltage soft starter to bypass assembly for Bypass soft starting in bypass mode S7 10 00 Inch 254 0 mm cabinet allows for special components customer supplied components or oversized cables Enclosure NOTE Enclosure expansion rated Type 1 only S8 20 00 Inch 508 0 mm Expansion Expansion cabinet allows for special components customer supplied components or oversized cables Enclosure NOTE Enclosure expansion rated Type 1 only S9 Space Heater Prevents condensation from forming in the enclosure when the drive is inactive or in storage Includes a thermostat
272. e refer to SPX9000 installation manual for mounting instructions FR13 is built from an inverter module and a converter module Please refer to SPX9000 installation manual for mounting instructions V6 T2 156 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives Approximate Dimensions Inches mm FR13 Open Chassis Converter W3 Dia 3 D ole 5 08 07 D6 ia 1 W4 W4 W4 gt lt D1 r lt D2 lt W1 gt n q a pe 0 08 gi h m aan 8 A Sena 22 2 H3 H1 H4 Hle Q 250 C a YU T a oF ar a W2 W2 Dia 2 Weight wi W W W W H H2 H H4 H5 01 02 03 D4 D 06 07 D 1 Dia 2 Dia 3 16 18 74 591 1752 457 335 41 54 246 3986 41 34 0 69 1469 0 51 0 73 642 256 1 06 157 591 524 035x059 051 0 37 295 134 476 150 445 116 85 1055 62 5 1012 5 1050 17 5 373 13 18 5 163 65 27 40 150 133 8x15 13
273. eactors or chokes critical to performance 0 126 0 13225 0 1385 0 14475 0 151 Substantial reduction up to approx 85 in voltage and current harmonics Provides increased input protection for AFD and its semiconductors from line transients Transformers often require separate mounting or larger AFD enclosures May not reduce distribution harmonic levels to below IEEE 519 1992 guidelines Cannot retrofit for most AFDs Time in Seconds Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 225 28 9000 Drives 3 Clean Power Drives When the total load is of non linear the greatest harmonic mitigation is required Under these conditions the currents drawn from the supply need to be sinusoidal and clean such that system interference and additional losses are negligible Eaton s CPX9000 clean power drive uses a phase shifting auto transformer with delta connected winding Three of the output phases are advanced and three are retarded The remaining three phases of this nine phase supply are in phase with the incoming line This results in nine separate phases In this type of configuration the total required kVA rating of the transformer is only 4896 of a drive rate isolation transformer A traditional isolated transformer system with multipulse windings would require the full Basic 18 Pulse Rectifier with Phase Shifting Transformer 18 Pulse SCR Br
274. ed NEMA Type 12 IP54 3R Drive SVX 0102 4 E P Build Alphabetically and Numerically A Product Family Enclosed Options Type SVX Enclosed drives K1 Door mounted speed potentiometer Control K2 Door mounted speed potentiometer with selector Control switch Horsepower Rating K5 MANUAL AUTO reference switch 22 mm Control 07 3 4 hp 015 15hp 100 100 hp K6 START and STOP pushbuttons 22 mm Control 001 1 hp 020 20 hp 125 125 hp K9 2 Factory installed auxiliary contacts Power 15 1 1 2 hp 025 25 hp 150 150 hp POWER ON RUN and Fault pilot lights Light 002 2 hp 030 30 hp 200 200 hp 12 Bypass pilot lights for RA bypass option Addl bypass 003 3 hp 040 40 hp 250 250 hp LD Green STOP light Light 005 5 hp 050 50 hp 300 300 hp LE Red RUN light Light 007 7 1 2 hp 060 60 hp 350 350 hp LU Misc light 22 mm Light 010 10 hp 075 75 hp 400 400 hp LW PIT light 22 mm Light P1 Inputcircuit breaker Input P3 Input fuses 200 kAIC Input Enclosure Rating P8 SPD 50 per phase Input 2 Type 12 IP54 SPD 100 Input 3 NEMA Type 3R PE Output contactor Output PF Outputfilter Output PG MotoRX 300 600 ft 1000 V uS DV DT filter Output Voltage Rating RA Manual HOA bypass controller Bypass Three phase Single p
275. eed sources Start and speed sources include keypad 1 0 and fieldbus KB 115V Control Transformer 550 VA Provides a fused control power transformer with additional 550 VA at 115V for customer use Control Power and Fault Pilot Lights Provide white power light that indicates power to the enclosed cabinet red fault light that indicates drive fault Ligh has occurred P2 Disconnect Switch Disconnect switch option is applicable only with NEMA 1 IP21 and NEMA Type 12 IP54 Freestanding drives Allows a convenient Input means of disconnecting the SPX9000 from the line and the operating mechanism can be padlocked in the OFF position This is factory mounted in the enclosure SPX Freestanding 0ptions 480V and 690V Control Options 200 550 hp Catalog Number Description Suffix Door mounted speed potentiometer with HOA selector switch K2 HAND OFF AUTO switch 22 mm K4 115 volt control transformer 550 VA KB 480V and 690V Light Options 200 550 hp Catalog Number Description Suffix Power on fault pilot lights Input Options 200 550 hp Catalog Number Description Suffix Disconnect switch 2 Notes Consult factory for adder information Applicable with FR10 and FR11 freestanding designs only V6 T2 134 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Replacement Parts FR4 Spare Parts Adjustable Frequency D
276. ep speed control PID control Multi purpose control Pump and fan control with auto change Standards and Certifications Product at default settings IEC 61800 2 Immunity Fulfills all immunity requirements Safety Emissions EN 61800 3 UL 508C LEVEL H V6 T2 120 Adjustable Frequency Drives Additional and communication cards provide plug and play functionality I O connections with simple quick connection terminals Control logic can be powered from an external auxiliary control panel internal drive functions and fieldbus if necessary Brake chopper standard from 1 30 hp 380 500V 3 4 15 hp 208 230V NEMA 1 21 enclosures available Frame Sizes FR4 FR11 Type 12 IP54 enclosures available Frame Sizes FR4 FR10 FR10 and FR11 freestanding drives Open chassis FR10 and greater Standard option board configuration includes an A9 I O board and an 2 relay output board installed in slots A and B UL Listed CE Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives Catalog Number Selection SPX9000 Adjustable Frequency Drives VIV M E TAR 3 Z Y m W Options Product Family Options appear in alph
277. es SPX9000 Drives 50 Duty Cycle 150 Torque Catalog Number Dimensions Inches 2 100 0 DBR R100 W0400 12W x 5D x 5H DBR R100 W1200 12W x 10D x 5H 3 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2000 12W x 16D x 5H 4 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2400 19W x 10D x 5H 5 100 0 DBR R100 W0800 12W x 7D x 5H DBR R100 W2800 19W x 13D x 5H 75 100 0 DBR R100 W1200 12W x 10D x 5H DBR R100 W4800 26 5W x 13D x 5H 10 30 0 DBR R063 W1600 12W x 13D x5H DBR R063 W6000 26 5W x 16D x 5H 15 30 0 DBR R042 W2400 19W x 10D x5H DBR R042 W9000 28W x 10D x 10H 20 30 0 DBR R030 W3200 19W x 13D x5H DBR R030 W012K 28W x 13D x 10H 25 30 0 DBR R030 W4000 19W x 16D x5H DBR R030 W015K 28W x 16D x 10H 30 18 0 DBR R020 W4800 26 5W x 13D x 5H DBR R020 W020K 30W x 18D x 16H 40 18 0 DBR R030 W6000 26 5W x 16D x 5H DBR R184 W025K 30W x 18D x 16H 50 9 0 DBR R013 W7500 26 5W x 16D x 5H DBR R012 W030K 30W x 18D x 24H 60 9 0 DBR R010 W9000 28W x 10D x 10H DBR R010 W036K 30W x 18D x 24H 75 9 0 DBR R009 W012K 28W x 13D x 10H DBR R009 W045K 30W x 18D x 24H 100 7 0 DBR R013 W015K 28W x 16D x 10H DBR R8D4 WO60K 30W x 18D x 40H 125 70 DBR R8D2 W020K 30W x 18D x 10H DBR R007 W070K 30W x 18D x 40H 150 7 0 DBR R007 WO25K 30W x 18D x 16H DBR R006 WO085K 30W x 18D x 56H 175 70 DBR R007 W030K 30W x 18D x 24H DBR R007 W100K 30W x 18D x 72H 200 25 DBR R3D3 W030K 30W x 18D x 24H DBR R2D6 W1
278. es Product aaa aana ag erga Y RU eed V6 T2 171 Product Laws V6 T2 173 2 7 CFX9000 Drives FEOGQUEC DSSCHBEOD 235855556 bai V6 T2 188 Produet IB I ca y aco ep a loe ede oe pee W acid eon V6 T2 197 2 8 CPX9000 Drives Prodoot ud EE dI Ed dide ER due paq d BOs V6 T2 221 Product Selection isa darker s Waka A Ede V6 T2 229 2 9 LCX9000 Drives cuiua equ abes odd edd V6 T2 251 Product 22222222266 de 24450 E 0484 V6 T2 253 2 10 SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Prodont Ego boku Peek eee Redes Eas V6 T2 268 Product Selection cage cad idee hence V6 T2 272 57 Drawings An Eaton KW Online Green Solution Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 1 2 1 9000 Drives 9000 Drives 0000 OH 00 0 Product Description NFX9000 Adjustable Frequency AC Drives from Eaton s Electrical Sector are designed to provide adjustable speed control of three phase motors These microprocessor based drives have standard features that can be programmed to tailor the drive s performance to suit a wide variety of application requirements The NFX9000 volts per hertz product line utilizes a 32 bit microprocessor and ins
279. fault Settings EMC Category C1 C2 and C3 at default settings 1m 25m Note See unit nameplate for more detailed approvals CA08100007E May 2014 www eaton com DC1 PID controller as standard Several fieldbus options SmartWire capability Removable I O terminal blocks Contactor style power wiring Compatibility with single phase motors DC1 200 torque at zero speed DA1 Ability to run permanent magnet motors DA1 PLC programming DA1 Closed loop DA1 Conformal coated boards DA1 Safety 61800 5 1 EN 60529 UL cUL UkrSepro c Tick RoHS compliant w 0 Rots Adjustable Frequency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency AC Drives Catalog Number Selection DC1 Series Adjustable Frequency AC Drives DC1 12 401 F N A 20 N ANA Device Series Type DC1 Variable frequency drive compact Series 1 N Standard basic device 0 Drives Compact 1 Series 1 Degree of Protection Connection in Power Section 20 IP20 NEMA 0 1 Single phase mains connection three phase motor connection 66 IP66 NEMA 4 3 Three phase mains connection three phase motor connection 6S IP66 with disconnect NEMA 4 S Single phase mains connection single phase motor connection Display Unit Display Mains Voltage Category A LED display
280. fication Input Output Interface Features 45 66 Hz input frequency Standard Setup adjustment provisions Output AC volts maximum Input Voltage Base Remote keypad display Standard Output frequency range 0 320 Hz Personal computer Standard Initial output current ly 250 for 2 seconds Operator control provisions Overload 1 minute 150 110 Drive mounted keypad display Standard Enclosure space heater Optiona Remote keypad display Standard Oversize enclosure Standard Conventional control elements Standard Output contactor Optiona Serial communications Optional Bypass motor starter Optiona 115 Vac control circuit Optional Listings UL cUL 508C Speed setting inputs Protection Features Keypad Standard Incoming line fuses Optiona 0 10 potentiometer voltage signal Standard AC input circuit disconnect Optiona 4 20 mA isolated Configurable Phase rotation insensitive Standard 4 20 mA differential Configurable EMI filter Standard FR6 thru FR9 9 3 15 psig Optional Input phase loss protection Standard Analog outputs Input overvoltage protection Standard Speed frequency Standard Line surge protection Standard Torque load current Programmable Output short circuit protection Standard Motor voltage Programmable Output ground fault protection Standard Kilowatts Programmable Output pha
281. for variable temperature control Enclosure The heater requires a customer supplied 115V remote supply source Dissipated Watt Losses Horsepower 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 800 Watts 1844 2170 2540 3040 4011 4940 5730 8020 9383 11600 13600 15700 16250 17976 20393 27200 31400 Conformal Varnished Coating 480V Input Disconnect Selection Chassis Delivery Chassis Delivery P1 Input Bypass Motor Circuit Protector Frame Code Frame Code Horsepower Breaker RA RB RC RD FR6 FP FR9 FP 25 HFD3050 050 2 FR7 FP FR10 FP 30 HFD3060 HMCP100R3C FR8 FP FR11 FP 40 HFD3080 HMCP100R3C FR12 FP 50 HFD3100 HMCP100R3C 60 HFD3100 HMCP150T4C 75 HFD3125 150 4 100 HFD3150 15004 125 HFD3200 HMCP250W5C 150 HFD3225 HMCP250W5C 200 HKD3300 HMCP400X5C 250 HKD3400 HMCP400X5C 300 400 HLD3600 HMCP600L6W 500 600 HND3800 HMCP800X7W Notes 650 800 HND312 See catalog number description to order Contact factory for 208V and 575V applications Contact factory V6 T2 240 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 8 9000 Drives Enclosed Drive Options Light Options Meter Options 2 Catalog Catalog Description Number Suffix Description Number Suffix Power on run fault LED lights 22 Standard ela
282. g Lbs kg Three Phase 208V 3 4 10 1 15 33 00 2136 29 67 25 35 21 05 16 92 15 30 2 07 17 24 16 26 3 31 170 77 215 98 230V 3 A30 1 15 838 2 796 5 753 6 6430 5347 4298 388 6 52 6 437 9 4130 841 480V 1 25 1 30 Single Phase 230 3 4 10 3300 31 36 29 67 25 35 21 05 16 92 15 30 2 07 17 24 16 26 3 31 170 77 215 98 1807 3 4 20 838 2 7965 7536 643 9 5347 429 8 3886 52 6 437 9 4130 841 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 115 2 4 Adjustable Freguency Drives 5 9000 Drives Approximate Dimensions in Inches mm Enclosure Box B NEMIA Type 3R w 0 44 11 2 Mounting Holes 4 Places Approx Approx Voltage hp hp Weight Shipping Weight AC ly I H H1 H2 H3 w W1 W2 W3 D D1 D2 Lbs kg Lbs kg Three Phase 208V 15 25 20 30 46 09 4445 42 77 36 35 26 31 20 92 19 30 2 69 17 74 16 76 3 31 235 290 230 1525 20220 1170 7 1129 0 10864 9233 668 3 5314 4902 683 450 8 4257 841 107 132 480V 30 60 10 75 Single Phase 230V 15 20 46 09 4445 42 77 36 35 26 31 20 92 19 30 2 69 17 74 16 76 3 31 235 290 1170 7 1129 0 1086 4 923 3 668 3 5314 490 2 68 3 450 6 425 7 84 1 107 132 480V 25 30 V6 T2 116 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives
283. gle overload relay Output PI Dual overload relays Output Voltage Rating PN Dual overloads for bypass Addl bypass 2 230V 208 240V RA Manual HOA bypass controller Bypass 4 480V RB Manual IOB bypass controller Bypass RC Auto transfer HOA bypass controller Bypass 5 575V 575 600 RD Auto transfer bypass controller Bypass RG Reduced voltage starter for bypass Bypass Application Torque Braking S7 10 00 inch 254 0 mm expansion Enclosure 1 brake chopper 8 20 00 inch 508 0 mm expansion Enclosure li internal brake chopper s9 Space heater Enclosure D l4 no brake chopper E l internal brake chopper Communication Options C2 Modbus Johnson Controls 2 Enelosedsmie C3 PROFIBUS DP CI Modbus TCP A Enclosed drive C4 LonWorks CJ BACnet C5 PROFIBUS DP D9 connector EtherNet IP C6 CANopen slave D3 RS 232 with D9 connection C7 DeviceNet M C8 Modbus 09 Type connector Control Options B1 6 DI 1 ext 24 Vdc ext 424 B2 1 NC NO 1 RO NO 1 therm 4 1 Al mA isolated 2 AO mA isolated 1 ext 24 Vdc EXT 24 B5 3 RO NO B8 1 ext 24 Vdc ext 24 3 Pt100 B9 1 RO NO 5 DI 42 240 Vac input Engineered Options HT High temperature rating for 50 FR10 and above VB Varnished boards Notes Brake chopper is standard in drives up to 30 hp ly or 40 hp at 480V It is optional in larger drives Local rem
284. gs Output voltage 0 to Vi Continuous output current rated 100 at 1229 50 C FR9 and below li rated 100 at 10491 40 FR9 and below 16 11 100 at 1049 40 C FR10 and above A alog input voltage 0 to 10V R 200 kohms 10 to 10V joystick control resolution 0 1 accuracy 1 Analog input current 0 4 to 20 mA 250 ohms differential Digital inputs 6 Positive or negative logic 18 to 30 Vdc Auxiliary voltage 24V 31596 max 250 mA Output reference voltage 10V 4396 max load 10 mA Analog output 0 4 to 20 mA max 500 ohms resolution 10 bit accuracy 2 Digital outputs Open collector output 50 mA 48V Overload current 19 11 150 110 1 min Output frequency 0 to 320 Hz Frequency resolution 0 01 Hz Initial output current lh 250 for 2 seconds Control Characteristics Control method Frequency control V f Open loop Sensorless vector control Closed loop SPX9000 drives only Relay outputs Two programmable Form C relay outputs switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Protections Overcurrent protection rip limit 4 0 x Ih instantaneously Overvoltage protection Yes Undervoltage protection Yes Earth fault protection n case of earth fault in motor or motor cable only the requency converter is protected Switching frequency Frame 4 6 Fram
285. hase 55 Floor stand 22 in Enclosure 1 208V J 230V S9 Space heater w out CPT Enclosure 2 230V 480V SA Space heater w CPT Enclosure 4 480V SB Sockettype control relay Enclosure SE On delay timer Enclosure SF Off delay timer Enclosure Application Torque Braking 1 brake chopper brake chopper Communication Options C2 Modbus D brake chopper C3 PROFIBUS DP lh internal brake chopper C4 LonWorks C5 PROFIBUS DP D9 connector C6 CANopen slave C7 DeviceNet C8 Modbus D9 type connector CA Johnson Controls N2 CI Modbus CJ BACnet EtherNet IP 03 5 232 with 09 connection Enclosed Style P Pumping application Control Options B1 6 DI 1 ext 24 Vdc EXT 24 B2 1 RO NC NO 1 RO NO 1 therm B4 1 Al mA isolated 2 AO mA isolated 1 ext 24 Vdc EXT 24 B5 3 RO B8 1 ext 424 Vdc EXT 424 3 Pt100 B9 1 RO NO 5 DI 42 240 Vac input Local remote keypad is included as the standard control panel Brake chopper is a factory installed option only see drive options on Page V6 T2 37 External dynamic braking resistors not included See Page V6 T2 46 G Includes local remote speed reference switch Some options are voltage and or horsepower specific Consult your Eaton representative for details See Page V6
286. he motor current is less than or equal to the MMX rated continuous output current For 208V 380V or 415V applications select the unit such that the motor current is less than or equal to the MMX rated continuous output current Units are also available without EMC filters Substitute 0 0 for this option Units are also available without EMC filters and 5 DC choke Substitute 0 0 for this option Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 25 7 3 Adjustable Freguency Drives Series Adjustable Freguency Drives Accessories Copy Paste Module Description Catalog Number Module is plugged onto the front of the drive to provide upload download of all parameters MMX COM PC direct link to a PC via USB interface for parameter assignment via MaxConnect software and copying of parameters for a series of devices or when exchanging devices No PC required PC Cable Description Catalog Number Remote download USB to RJ 45 cable with software driver disk REM USB DOWN NEMA Type 1 Kits Description Catalog Number NEMA Type 1 and IP21 kit for frame 1 MMX IP21 FS1 NEMA Type 1 and IP21 kit for frame 2 MMX IP21 FS2 NEMA Type 1 and IP21 kit for frame 3 MMX IP21 FS3 NEMA Type 1 for frame 4 MMX CKIT FS4 NEMA Type 1 for frame 5 MMX CKIT FS5 Optional Communication Modules 9 Description Catalog Number Communication adapter kit F51 FS
287. hich can damage the diode bridge nput of the drive PC Capacitor Contactor This option provides contactor between the tuned reactor and capacitor to disconnect the capacitor from the circuit when desired typically at Input light or no load conditions This contactor is wired to a programmable relay output PE Output Contactor Provides a means for positive disconnection of the drive output from the motor terminals The contactor coil is controlled by the drive s run or Outpu permissive logic NO auxiliary contacts rated at 10A 600 Vac are provided for customer use Bypass options RB and RA include an output contactor as standard This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure PF Output Filter Used to reduce the transient voltage DV DT at the motor terminals The output filter is recommended for cable lengths exceeding 100 ft 30m or fora drive rated at 525 690V This option is mounted in the enclosure and may be used in conjunction with a brake chopper circuit PG MotoRx 300 600 ft 1000 V uS DV DT Filter Used to reduce transient voltage DV DT and peak voltages at the motor terminals This option is comprised of a 0 5 Outpu line reactor followed by capacitive filtering and an energy recovery clamping circuit Unlike the output filter see option PF the MotoRx recovers most of the energy from the voltage peaks resulting in a lower voltage drop to
288. ht 22 mm Provides a red RUN pilot light that indicates the drive is running Light LF Red STOP Light 22 mm Provides red STOP light that indicates the drive is stopped Ligh LJ White POWER ON Light 22 mm Provides a white POWER light that indicates power to the enclosed cabinet Ligh LU Misc Light 22 mm Provides a misc user defined pilot light User to define light function and color Ligh P1 Input Circuit Breaker Provides a means of short circuit protection for the power cables between it and the SVX9000 and protection from high level ground faults Input the power cable Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position This is factory mounted in the enclosure P3 Input Line Fuses Rated to 200 kAIC Provides high level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the nput power transistors This option consists of three 200 kA fuses which are factory mounted in the enclosure P8 SPD 50 kA per Phase Provides a surge protection device SPD connected to the line side terminals and is designed to clip line side transients nput Rated for 50 000A PA SPD 100 per Phase Provides a surge protection device SPD connected to the line side terminals and is designed to clip line side transients nput Rated for 100 000A PE Output Contactor Provides a means for posi
289. iDisconnect Power Wiring Incoming Power ci 12 2 6 Circuit Breaker Optional Fuse Input Drive Output U T1 V T2 W T3 Optional Output Contactor U T1 W T3 CA08100007E May 2014 www eaton com V6 T2 183 2 6 Adjustable Frequency Drives H Max Series Drives Dimensions Approximate Dimensions in Inches mm H Max Series IntelliPass and IntelliDisconnect Drives H3 A M PN Lx O H4 H1 H2 Ls IAI IA Y O Y Y LI l w3 lt W2 gt lt D2 gt Consult factory or use manual for final dimensions Frame Weight in Size Voltage Horsepower 11 H1 H2 H3 H4 w1 w2 W3 D1 D2 Lbs kg FS4 208 1 3 29 69 37 12 0 25 31 00 3 00 7 88 6 33 0 75 11 40 9 27 45 20 41 230 1 3 754 1 942 9 6 35 914 4 76 2 200 2 160 8 19 1 289 6 235 5 480 1 7 5 FS5 208 5 10 37 00 34 47 0 25 38 31 3 00 940 7 75 0 75 15 30 13 17 57 5 26 10 230 5 10 939 8 875 5 6 35 973 0 76 2 238 8 196 9 19 1 388 6 334 6 480 10 20 FS6 208 15 20 45 08 40 28 0 25 46 4 4 00 1
290. ic braking Optional DC braking Standard PID setpoint controller Programmable Two analog input configurable w jumpers Voltage 0 10V gt 200 kohms Current 0 4 20 mA 250 kohms Two digital output programmable Form relays 250 30 Vdc 2 Amp resistive One digital output programmable Open collector 48 Vdc 50 mA One analog output programmable configurable w jumper 0 20 mA max 500 ohms 10 bits 2 Critical speed lockout Standard I O Specifications for Control Communication Options Current torque limit Standard Description Specification Adjustable acceleration deceleration Standard Analog voltage input 0 10 R 2200 kilohms Linear or S curve accel decel Standard Analog current input 0 4 20 mA 250 ohms Jog at preset speed Standard Digital input 24V 0 lt 10V 1 218V R gt 5 kilohms Thread preset speeds 7 Auxiliary voltage 24V 20 max 50 mA Automatic restari Selectable Reference voltage 10V 3 max 10 mA Coasting motor start Standard Analog current output 0 4 20 mA R 500 kilohms resolution Coast or ramp stop selection Standard PORADE Elapsed time meter Optional Analog voltage output 0 2 10V gt 1 kohm resolution Standard Conditions for Application and Service Maximum operating ambient temperature 0 to 40 C contact factory for 50 C Storage temperatu e
291. idge Rectifier Converter Section 18 Pulse Phase Shifting 3 Phase AC Input Auto Transformer Diode Rectifiers Adjustable Frequency Drives rating to be supported which is more common in an MV step down transformer The integrated 18 pulse clean power drive with near sine wave input current and low harmonics will meet the requirements of IEEE 519 1992 under all practical operating conditions The comparisons with six pulse and 12 pulse systems are shown see Pages V6 T2 223 6 2 225 and V6 T2 226 Inverter Section DC Dynamic Braking Transistor OutputTransistors IGBT Section Bus Capacitors 500 hp 480V Drive with 18 Pulse Rectifiers Current Amps 1000 500 500 hp 480V Drive with 18 Pulse Rectifiers 18 Pulse Clean Power Current harmonics 100 l5 0 16 l1 0 24 1132 0 1096 hg 1 0096 log 0 0196 500 1000 0 126 0 13225 0 1385 0 14475 0 151 Seconds V6 T2 226 Volume 6 Solid State Motor Control 5 0 0396 Power 500 hp 17 0 86 ly 0 01 24 amps Advantages Disadvantages e Virtually guarantees e Not as cost effective as compliance with some other methods at IEEE 51
292. ing for Bottom Cable Entry 4 Places i 8 50 18 75 215 9 476 3 bi 8 00 203 2 Construction UL 1 Oversize Finish Enclosure ANSI 61 Gray Light V6 T2 218 Volume 6 Solid State Motor Control 1 1 75 44 5 24 45 621 0 28 05 712 5 Approximate Shipping Weight Lbs kg 1000 454 Bottom View CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 7 9000 Drives Approximate Dimensions Inches mm Enclosure Size 8 31 00 787 4 1 25 31 8 8 209 6 Opening for Top Cable Entry A 2 Places t T 7 4 00 101 6 Free Air Space Required Keypad Flanged Disconnect Supplied with Circuit Breaker When Specified Operator Elements When Specified Mounted onThese Panels Door Handle key lock optional s 90 00 84 37 77 2286 0 2143 0 Intake Ventilating Slots Filtered on NEMA 12 Quarter Turn Latch 2 Places to Y Y Y 24 00 609 6 lt 21 45 544 8 gt lt 21 31 541 3 gt lt n oH F y I 25 14 639 48 00 1249 2 Front View Side View 56 14 2 Dia 9 50 Mounting Holes gt 241 4 N LI
293. ion Number Suffix Description Number Suffix Input breaker P1 Manual H0A bypass controller RA Output contactor PE IOB bypass controller RB Single overload relay PH Auto transfer bypass controller RC Dual overload relays PI Auto transfer bypass controller RD MOV P7 Reduced voltage starter for bypass RG 50 kA surge protective device P8 Dual overloads for bypass PN 100 kA surge protective device P9 480 and 575V Bypass Options 25 800 hp 480 and 575V Power Options 25 800 hp Catalog Catalog Description Number Suffix Description Number Suffix Manual HOA bypass controller RA Input breaker P1 IOB bypass controller RB Output contactor PE Auto transfer bypass controller RC Output filter PF Auto transfer bypass controller RD MotoRx 300 600 Ft DV DT filter PG Reduced voltage starter for bypass RG Single overload relay PH Dual overloads for bypass PN Dual overload relays Input MOV P7 50 kA surge protective device P8 100 kA surge protective device P8 V6 T2 242 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 9000 Drives Technical Data and Specifications 9000 Drives Description Specification Primary Design Features Description Specification 2 8 Input Output Interface Features
294. is 300 600 ft 91 4 182 9m PH Single Overload Relay Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options It is included with the bypass configurations for overload current protection in the bypass mode overload relay is mounted within the enclosure and is manually resettable Heater pack included Dual Overload Relays This option is recommended when single drive is operating two motors and overload current protection is needed for each of the motors standard configuration includes two bimetallic overload relays each sized to protect a motor with 50 of the drive hp rating For example 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable Heater packs not included PN Dual Overloads for Bypass This option is recommended when a single drive is operating two motors in the Bypass mode and overload current protection is needed Addl bypass for each of the motors The standard configuration includes two bimetallic overload relays each sized to protect a motor with 5096 of the drive hp rating For example a 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton c
295. ive kW 480 Vac Low Overload Full Catalog Size Load Amps at 40 Horsepower 400 Vac 50 Hz Amps Load Amps at 50 C Number 4 34 15 1 1 21 2 6 4 630422 48 2 1 5 34 34 4 640822 5 6 3 2 2 5 6 4 8 HMX34AG5D622 N 8 0 4 3 0 N A 5 6 HMX34AG8D022 N 9 6 5 4 7 6 8 HMX34AG9D622 N 12 75 5 5 11 9 6 HMX34AG01222 N 5 16 10 75 14 12 HMX34AG01622 N 23 15 11 21 16 HMX34AG02322 N 31 20 15 27 23 HMX34AG03122 N 6 38 25 18 5 34 31 HMX34AG03822 N 46 30 22 40 38 HMX34AG04622 N 61 40 30 52 46 HMX34AG06122 N 7 72 50 37 65 61 HMX34AG07222 N 87 60 45 77 72 HMX34AG08722 N 105 75 55 96 87 HMX34AG10522 N 8 140 100 75 124 105 HMX34AG14022 N 170 125 90 156 140 HMX34AG17022 N 205 150 110 180 170 HMX34AG20522 N 9 261 200 132 240 205 HMX34AG26122 N 310 250 160 302 261 HMX34AG31022 N Note For sizing reference Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 165 2 6 Series Drives Onboard Network Communications Johnson Controls Metasys N2 Series provides communication between the drive Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system N2 can be selected and programmed by the drive keypad BACnet H Max Series provides communication to BACnet networks Data transfer is master slave token passing MS TP RS 485 BACnet 100Base T interface Modbus TCP
296. ives Catalog Number Selection 9000 Enclosed Drive Adjustable Freguency Drives C P X 1 0 0 1 4 Build options alphabetically and numerically Product Family Enclosed Options Type CPX Clean power 18 pulse K1 Door mounted speed potentiometer Control enclosed drives K2 Door mounted speed potentiometer with HOA selector switch Control K3 3 15 psig follower Control Ka HAND OFF AUTO switch 0 87 inch 22 mm Control Horsepower Rating K5 MANUAL AUTO reference switch 0 87 inch 22 mm Control 025 25hp 100 100hp 350 350 hp K6 START STOP pushbuttons 0 87 inch 22 mm Control 030 30hp 125 125hp 400 400 hp KF Bypass test switch for RA and RB Addl bypass 040 40hp 150 150hp 500 500 hp KO Standard elapsed time meter Control 050 50hp 200 200hp 600 600 hp L1 Power RUN and fault pilot lights Ligh 060 60 250 250hp 700 700 12 Bypass pilot lights for RB bypass options Addl bypass 075 75hp 300 300 800 800hp LE Red RUN light Ligh P1 Input disconnect Inpu Enclosure Rating P8 Surge protective device Inpu 1 1 Output contactor Output 3 3R PF Output filter Output DES PG MotoRx up to 600 ft 182 9m 1000 V uS DV DT filter Output 6 Type 12 filtered PH Sin
297. ller output terminals with no other equipment connected in series or parallel Motor starters disconnect switches surge absorbers DV DT suppression circuits output chokes output transformers and any other equipment under consideration for installation on the output of the controller should not be installed without first requesting Application Engineering assistance Power factor correction capacitors must never under any circumstances be connected at the output of the controller They would serve no useful purpose and they may damage the controller CA08100007E May 2014 www eaton com Enclosure Definitions NEMA Type 1 IP21 Enclosures are intended for indoor use primarily to provide a degree of protection against contact with enclosed equipment and provide a degree of protection against a limited amount of falling dirt in locations where unusual service conditions do not exist Top or side openings in the NEMA Type 1 IP21 enclosure allow for the free exchange of inside and outside air while meeting the UL rod entry and rust resistance design tests e NEMA Type 12 IP54 Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust falling dirt and dripping noncorrosive liquids To meet UL drip dust and rust resistance tests NEMA Type 12 IP54 enclosures have no openings to allow for the exchange of inside and outside air e Chassis IP00 Simila
298. lt 9 37 238 ej 39 13 79 350 n LL m A A eoh A loh olo 59 gt 16 1394 KE 421 2 64 354 8 pz 67 3 75 die 1 1 0 2 2 Oo Jl m 15 U 5 51 5 90 lt gt 690 lt 10 30 262 gt lt 10 83 275 CHK0261 fo 0 0 0 0 o 24 e for He 6 RER 4 72 4 72 42 42 lt 13 79 350 gt 8 11 206 1 54 ay 1 8 59 A 8 4 06 14 118 12 56 87 lt 357 22 y 50 120 319 3 ola 0 F 15 o 0 oh 9 Y V Y 4 25 5 90 39 lt 175 19 150 7 Per 9 06 230 Min lt 10 83 275 V6 T2 160 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives H Max Series Drives Product Overview H Max Family Introduction Eaton s H Max Series VFD is the next generation of drives specifically engineered for HVAC pump and fluid control applications The H Max family of products boasts industry leading energy efficiency algorithms for your applications Not only are the drives ultra efficient they contain software that minimizes motor winding energy loses in your applications Designed for easy installation simple startup and long life the H Max Series drive family provides exceptional value to our customers Product Range Open Style Drives 0 75 125 hp
299. ltage and current harmonics Avallable in various values of percent impedance Provides increased input protection for AFD and its semiconductors from line transients CA08100007E May 2014 www eaton com Disadvantages May not reduce harmonic levels to below IEEE 519 1992 guidelines Voltage drop due to loss V6 T2 191 2 9000 Drives 2 Passive Filters Tuned harmonic filters involve the series connection of an inductor with the shunt connection of an inductor and capacitor to form a low impedance path to ground for a specific range of frequencies This path presents an alternative to the flow of harmonic currents back into the utility source CFX9000 Drive with Integrated Passive Filter Tuned Harmonic Capacitor Three Phase Input Bus Capacitors 100 hp CFX9000 480V Drive with Integrated Passive Filter Current Amps 200 100 100 200 V6 T2 192 Time Volume 6 Solid State Motor Control Dynamic Braking Adjustable Frequency Drives Transistor Output Transistors IGBT Section AR 6 Pulse Diode Inverter Section Shunt Bridge Rectifier Fusing Converter Section 1 Shunt Reactor MIATAT 1 4 4 2 l
300. lternative PH Single Overload Relay Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options Itis included with the bypass configurations for overload current protection in the bypass mode The overload relay is mounted within the enclosure and is manually resettable Heater pack included Dual Overload Relays This option is recommended when single drive is operating two motors and overload current protection is needed for each of the motors The standard configuration includes two bimetallic overload relays each sized to protect a motor with 50 of the drive hp rating For example a 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable Heater packs not included PN Dual Overloads for Bypass This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed Addl bypass for each of the motors The standard configuration includes two bimetallic overload relays each sized to protect a motor with 5096 of the drive hp rating For example a 100 hp drive would include two overload relays sized to protect two 50 hp motors The relays are mounted within the enclosure and are manually resettable V6 T2 84 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adj
301. m 601 100 2 Al 1 AO A OPTA8 A8 3 DI encoder 10 24V out 15V 24V C OPTAE AE 2 DO pulse direction 6 DI 1 ext 24 Vdc EXT 24 B C D E 1 B1 1 1 RO NO 1 therm C D E 0 2 B2 1 Al mA isolated 2 AO mA isolated B C D E 0PTB4 4 u u u u 1 ext 24 Vdc EXT 24 3 RO B C D E OPTB5 B5 1 ext 24 Vdc EXT 24 Vdc 3 Pt100 B C D E 8 B8 1 NO 5 DI 42 240 Vac input C D E OPTB9 B9 SPI absolute encoder C 0 BB Communication Modbus D E 0 2 cz Johnson Controls N2 D E OPTC2 CA Modbus TCP D E Cl u u u BACnet D E u u EtherNet IP D E OPTCQ ca u u u PROFIBUS DP D E LonWorks D E OPTC4 C4 PROFIBUS DP 09 connector DE OPTC5 C5 u u u u u u u CANopen slave D E OPTC6 C6 u u u u u u u DeviceNet D E 7 C7 Modbus 09 type D OPTC8 C8 Adapter D E OPTD1 D1 u Adapter D E OPTD2 D2 u u RS 232 with 09 connection D E OPTD3 D3 9000 Series local remote keypad KEYPAD replacement keypad LOC REM 9000X Series remote mount keypad unit OPTRMT keypad not included includes 10 ft cable KIT 9000X keypad holder mounting hardware 900
302. m can be padlocked in the OFF position This is factory mounted in the enclosure Standard rating is 65 kAIC at 208 480V 100 kAIC is available as an option PE Output Contactor Provides a means for positive disconnection of the drive output from the motor terminals The contactor coil is controlled by the drive s run or permissive logic NC and auxiliary contacts rated at 10A 600 are provided for customer use Bypass options RB and RA include an output contactor as standard This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure PF Output Filter Used to reduce the transient voltage DV DT at the motor terminals The output filter is recommended for cable lengths exceeding 100 ft 30 5m with a drive of hp and above for cable lengths of 33 ft 10 1m with a drive of 2 hp and below for a drive rated at 525 690V This option is mounted in the enclosure PG MotoRx 300 600 Ft 1000 V uS DV DT Filter Used to reduce transient voltage DV DT and peak voltages at the motor terminals This option is comprised of a 0 5 line reactor followed by capacitive filtering and an energy recovery clamping circuit Unlike the output filter see option PF the MotoRx recovers most of the energy from the voltage peaks resulting in a lower voltage drop to the motor and therefore conserving power This option is used when the distance between a single motor and the drive
303. mA Current input frequency reference 5 6 24 Control voltage output Voltage for switches etc max 0 1A 7 GND ground Ground for reference and controls 8 DINI Start forward Contact closed start forward 9 DIN2 Start reverse Contact closed start reverse 0 DIN3 External fault input programmable Contact open no fault Contact closed fault 1 Common for DIN 1 DIN Connect to GND or 24V 2 Control voltage output Voltage for switches see terminal 6 13 GND 1 0 ground Ground for reference and controls 14 DIN4 Multi step speed select 1 DIN4 DIN5 Frequency Ref 5 DIN5 Multi step speed select 2 Open Open Ref Vin Closed Open Multi step ref 1 Open Closed Multi step ref 2 Closed Closed RefMax 16 DING Fault reset Contact open action Contact closed fault reset 7 CMB Common for DINA DING Connect to GND or 424V 18 A014 Output frequency Programmable Analog output Range 0 20 mA Ri max 500 ohms 19 01 20 Digital output Programmable READY Open collector lt 50 mA V 48 OPTA2 21 RO1 Relay output 1 RUN R01 23 RO1 24 02 Relay output 2 25 R02 26 R02 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 211 2 Dimensions Adjustable Freguency Drives 9000 Drives Approximate Dimensions Inches mm Enclosure Size B UL Type 12
304. mage to transformers and lower efficiencies due to the IR loss These losses can become significant from 16 6 21 6 which can have a dramatic effect on the HVAC systems that are controlling the temperatures of the building where the transformer and drive equipment reside Downtime and loss of productivity Telephones and data transmissions links may not be guaranteed to work on the same power grids polluted with harmonics Downtime and nuisance trips of drives and other equipment Emergency generators have up to three times the impedance that is found in a conventional utility source Thus the harmonic voltage can be up to three times as large causing risk of operation problems Larger motors must be used Motors running across the line that are connected on polluted power distribution grids can overheat or operate at lower efficiency due to harmonics Higher installation costs Transformers and power equipment must be oversized to accommodate the loss of efficiencies This is due to the harmonic currents circulating through the distribution without performing useful work V6 T2 189 2 9000 Drives How Does VFD Convert Three Phase AC to a Variable Output Voltage and Frequency The six pulse VFD The majority of all conventional drives that are built consist of a six pulse configuration The figure below represents a six diode rectifier design that converts three phase utility power
305. mber Designator Basic Remote Standard MSS PID Multi P PFC Standard Cards 6 DI 1 DO 2 Al TAO 1 10 ref 9 2 ext 24 Vdc EXT 24 2 RO NC NO B OPTA2 Extended Cards 6 DI 1 ext 24 Vdc EXT 24 B C D E 0 1 B1 1 RO 1 RO NO 1 therm B C D E 2 B2 1 Al mA isolated 2 AO mA isolated B C D E OPTB4 B4 1 ext 424 Vdc EXT 24 3 RO NO C D E OPTB5 B5 ext 24 Vdc EXT 24 Vdc 3 Pt100 B C D E 8 B8 1 RO NO 5 DI 42 240 input B C D E 0 9 9 Communication Cards Modbus D E 0 2 C2 u u u u u u u Modbus TCP D E nm u BACnet D E CJ u nm EtherNet IP DE OPTCQ ca Johnson Controls 2 D E OPTC2 CA PROFIBUS DP D C3 LonWorks D E OPTC4 C4 m m m PROFIBUS 09 connector D OPTC5 C5 u u u u u u u CANopen slave D E OPTC6 C6 u u u u u u u DeviceNet D E 7 C7 m m m m Modbus D9 type connector D E OPTC8 C8 RS 232 with 09 connection D OPTD3 D3 m Notes Al Analog Input AO Analog Output DI Digital Input DO Digital Output RO Relay Output Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location
306. me 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 173 2 6 Adjustable Freguency Drives Series Drives Series IntelliPass 12 Two Contactor Bypass Standard FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 6 HMX4D641NA 2 75 70541 3 10 6 HMX01141NA 5 5 16 7 HMX01741NA 75 24 2 HMX02541NA 10 30 8 HMX03141NA 6 15 46 2 HMX04741NA 20 59 4 HMX06041NA 7 25 74 9 HMX07541NA 30 88 HMX08841NA 230 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 4 2 HMX4D242NA 2 6 8 HMX6D842NA 3 9 6 HMX9D642NA 5 5 15 2 HMX01642NA 75 22 HMX02242NA 10 28 HMX02842NA 6 15 42 HMX04242NA 20 54 HMX05442NA 7 25 68 HMX06842NA 30 80 HMX08042NA 480 Vac FS Drive Rated Frame Size Horsepower NEC Amps Catalog Number 4 1 2 1 HMX2D144NA 2 3 4 HMX3D444NA 3 5 6 HMX5D644NA 5 7 6 HMX7D644NA 75 11 HMX01144NA 5 10 14 HMX01444NA 15 21 HMX02144NA 20 27 HMX02744NA 6 25 34 HMX03444NA 30 40 HMX04044NA 40 52 HMX05244NA 7 50 65 HMX06544NA 60 77 HMX07744NA 75 96 HMX09644NA Notes For Wiring Diagrams see Page V6 T2 183 For NEMA 12 or 3R enclosures see Catalog Number Selection on Page V6 T2 172 Call Technical Support for NEMA specifics Enclosure size and weight differ from NEMA 1 and 12 products V6 T2 174 Volume 6 Solid State Motor Control 08100007
307. me Delivery Catalog Size Code Number FR4 w OPTTHRFR4 FR5 OPTTHRFR5 FR6 IP54 Frames 4 9 Frame Size FRA FR5 FR6 FR7 FR8 FRO Delivery Catalog Code Number FP OPTTHR4 OPTTHRS OPTTHR6 OPTTHR7 OPTTHR8 OPTTHR9 For installation of an SPX9000 Type 1 IP21 drive into a NEMA Type 12 IP54 oversized enclosure Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 127 2 D Adjustable Frequency Drives SPX9000 Drives Options 9000X Series Option Board Kits 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes an A9 I O board and 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations 2 Number Designator Basic Remote Standard MSS PID Multi P PFC Standard I O Cards 6 DI 1 DO 2 Al TAO 1 10 ref A 9 2 ext 24 Vdc EXT 24 2 RO NC NO B OPTA2
308. mer s needs Consult your Eaton representative for assistance in pricing and lead time Features 12 IP54 or enclosures Input voltage 208V 230V 480V and 575V consult factory Complete range of control network and power options Horsepower range e 208V 3 4 to 100 hp ly 1 to 100 hp IL e 230V 3 4 to 100 hp ly 1 to 100 hp e 480V 1 to 350 hp ly 1 1 2 to 400 hp IL Padlockable disconnect Single phase input available Standards and Certifications UL Listed cUL Listed W 0 Listed Listed Contents Description SVX9000 Open Drives SVX9000 Enclosed Drives SVX9000 VFD Pump Panels Catalog Number Selection Product Selection SVX9000 Drives OPTIONS MCI Technical Data and Specifications Wiring Diagrams Dimensions Product Identification SVX9000 Pump Application 1 1 SVX9000 variable frequency drive 2 Input disconnect Option P1 3 Input contactor included as standard with bypass option 4 Space heater Option 9 5 Bypass contactor Option RA RB 6 Door mounted keypad included as standard Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 4 Page V6 T2 36 V6 T2 75 V6 T2 100 V6 T2 101 V6 T2 106 V6 T2 109 V6 T2 111 V6 T2 112 V6 T2 99 2 4 Adjustable Freguency Drives 5 9000 Drives Catalog Number Selection E SVX9000 Enclos
309. ming of the drive ensures a smooth start up Keypad can display up to three monitored parameters simultaneously LOCAL REMOTE operation from keypad Copy paste function allows transfer of parameter settings from one drive to the next Standard NEMA Type 12 IP54 keypad on all drives Adjustable Frequency Drives Contents Description SVX9000 Open Drives Standards and Certifications Catalog Number Selection Product Selection Accessories Options Replacement Parts Technical Data and Specifications Dimensions SVX9000 Enclosed Drives SVX9000 VFD Pump Panels Page V6 T2 37 V6 T2 37 V6 T2 38 V6 T2 42 V6 T2 43 V6 T2 49 V6 T2 58 V6 T2 59 V6 T2 75 V6 T2 99 The SVX can be flexibly adapted to a variety of needs using our pre installed Seven in One precision application programs consisting of Basic e Standard Local remote Multi step speed control PID control Multi purpose control Pump and fan control with auto change Additional I O and communication cards provide plug and play functionality I O connections with simple quick connection terminals CA08100007E May 2014 www eaton com Hand held auxiliary 24V power supply allows programming monitoring of control module without applying full power to the drive Control logic can be powered from an external auxiliary cont
310. mperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 5 V6 T2 137 2 5 Adjustable Frequency Drives SPX9000 Drives FR9 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan 50 mm fan 1 PP09041 PP09041 PP09041 80 mm fan 1 PP01068 PP01068 PP01068 Control module SPX control module 1 50000000000 50000000000 50000000000 Standard slot A 1 0 card 1 9 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 OPTA2 Converter Power module 1 FR09 0261 2 ANV FR09 0261 4 ANV FR09 0125 5 ANV 1 FR09 0300 2 ANV FR09 0300 4 ANV FR09 0144 5 ANV 1 09 0170 5 board 1 800583 800583 00583 Shunt board 6 VB00535 VB00537 6 VB00536 VB00542 6 VB00543 DC section Balancing resistor 3 00052 00052 00052 Bus capacitor 8 00335 00335 01041 DC busbars DC 1 809043 809043 809043 DC busbars DC 1 809044 FR09044 FR09044 DC busbars connection 1 FR09045 FR09045 FR09045 DC busbars insulator 1 FR09046 FR09046 FR09046 DC busbars con insulator 1 FR09047 FR09047 FR09047 Inverter Rectifier module 1 FR09826 FR09822 FR09823 Diode 3 01268 CP01268 CP01268 Rectifier board 1 VB00459 VB00460 Key
311. mum Motor Optimum Motor c a T ly A 1 A ly A at ly 400V kW at ly 500V kW kW Chassis Catalog Number 170 155 113 110 160 4 5 0 2 4 7 CH61 LCX170A0 5A7N2 208 189 139 132 200 5 5 0 3 5 8 CH61 LCX208A0 5A7N2 261 237 174 160 250 5 5 0 3 5 8 CH61 LCX261A0 5A7N2 325 295 217 200 300 6 5 0 3 6 8 CH62 LCX325A0 5A7N2 385 350 257 250 355 7 5 0 4 7 9 CH62 LCX385A0 5A7N2 416 378 277 250 355 8 0 0 4 8 4 CH62 LCX416A0 5A7N2 460 418 307 300 400 8 5 0 4 8 9 CH62 LCX460A0 5A7N2 502 456 335 355 450 10 0 0 5 10 5 CH62 LCX502A0 5A7N2 590 536 393 400 560 10 0 0 5 10 5 CH63 LCX590A0 5A7N2 650 591 433 450 600 13 5 0 7 14 2 CH63 LCX650A0 5A7N2 750 682 500 500 700 16 0 0 8 16 8 CH63 LCX750A0 5A7N2 820 745 547 560 800 16 0 0 8 16 8 CH64 LCX820A0 5A7N2 920 836 613 650 850 18 0 0 9 18 9 CH64 LCX920A0 5A7N2 1030 936 687 700 000 19 0 1 0 20 0 CH64 LCXH10A0 5A7N2 1180 1073 787 800 100 21 0 10 1 20 1 CH64 LCXH11A0 5A7N2 1300 1182 867 900 200 27 0 1 4 28 4 CH64 LCXH13A0 5A7N2 1500 1364 1000 1050 400 32 0 1 6 33 6 CH64 LCXH15A0 5A7N2 1700 1545 1133 1150 550 N A CH64 LCXH17A0 5A7N2 1850 1682 1233 1250 650 34 2 1 8 36 0 2 CH64 LCXH18A0 5A7N2 2120 1927 1413 1450 900 37 8 2 0 39 8 2 CH64 LCXH21A0 5A7N2 2340 2127 1560 1600 2100 48 6 2 5 51 1 2 CH64 LCXH23A0 5A7N2 2700 2455 1800 1850 2450 57 6 3 0 60 6 2 CH64 LCXH27A0 5A7N2 3100 2818 2066 2150 2800 N A 2 CH64 LCXH31A0 5A7N2 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 255 2 9 Adjusta
312. n the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position S5 Floor Stand 22 in Converts a Size 1 or 2 normally wall mounted enclosure to a floor standing enclosure with a height of 22 in 558 8 mm Enclosure S6 Floor Stand 12 in Converts a Size 2 normally wall mounted enclosure to a floor standing enclosure with a height of 12 in 304 8 mm Enclosure S7 10 in Expansion n a Size 5 enclosure the extension allows for bottom cable entry and additional space for customer mounted components Enclosure NOTE Enclosure expansion rated Type 1 IP21 only S8 20 in Expansion In a Size 5 enclosure the extension allows for bottom cable entry and additional space for customer mounted components When the output filter Enclosure option PF is selected for a drive using a Size 5 enclosure this expansion box is required and included in the option pricing Enclosure expansion rated NEMA Type 1 IP21 only S9 Space Heater Prevents condensation from forming in the enclosure when the drive is inactive or in storage Includes a thermostat for variable temperature control A Enclosure 200W heater is installed in enclosures 0 and 1 and a 400W heater is installed in enclosures 2 5 SA Space Heater with CPT Prevents condensation from forming in the enclosure when the drive is inacti
313. nce Al2 5 current DIN3 10 lt a 11 24 12 NE an 14 DIN5 15 DING GA qv l 1 CMB 17 lt A01 18 amp 0 4 20mA LHP now 9 20 Q V lt 48V I lt 50mA Dotted lines indicate the connections for inverted signals V6 T2 260 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 09 LCX9000 Drives A2 Option Board Wiring 2 I i 1 on G i RO1 2 22 i i i R i RO1 3 23 i AC DC i i i 1 RO2 1 29 Switching i Woo 8 A 24 i 02 2 25 lt 0 4A 125 i lt 8 A 250 Vac i 26 lt 2 Arms i Continuous Dimensions Approximate Dimensions in Inches mm Line Reactors Sizes Up To 61 Sizes Larger Than 61A ZWYVXU Mains 3 I c U H1 L w1 gt I lt D1 219 Converters lt W1 gt D1 Weight Catalog Number H1 wi D1 Lbs kg 0023 6 0 7 01 178 9 06 230 4 76 121 22 10 0038 6 0 8 23 209 10 63 270 5 71 145 33 15 0062 6
314. ncy but a hazard of personal injury or equipment damage may exist when the motor is operated above base speed Before adjusting the drive to operate above line frequency make sure that the motor and the driven machinery can safely be operated at the resulting speed V6 T2 34 Volume 6 Solid State Motor Control Features Controller Features Operator Control and Interface Requirements Since there are many possible configurations and many ways of achieving a specific end result it pays to consider the operator control and interface requirements carefully A simplified and more economical drive package can often be achieved by selecting from standard product offerings rather than specifying a custom designed configuration Installation Compatibility The successful application of an AC drive requires the assurance that the drive will be compatible with the environment in which it will be installed In planning the installation be sure to carefully consider the heat produced by the drive the altitude and temperature limits and the need for clean cooling air Other important considerations include acoustical noise vibration electromagnetic compatibility power quality controller input harmonic current and power distribution equipment requirements Adjustable Frequency Drives Auxiliary Equipment and Accessories Adjustable drives are generally designed to have a motor directly connected to the contro
315. nd 9 must be ordered from the factory a flange mount unit Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 167 2 6 Adjustable Freguency Drives Series Drives Technical Data and Specifications Series Drives Description Specification Input Ratings Description Specification Control Connections Input voltage Vin 200 240 Vac 380 480 10 10 Input frequency fin 50 60 Hz variation up to 47 66 Hz Connection to power Once per minute or less typical operation Short circuit withstand rating 100 Output Ratings Output voltage 0 to V n Ui line voltage in Continuous output current Ambient temperature max 10491 40 C overload 1 1 xl 1 min 10 min Overload current 110 1 min 10 min Initial output current 150 for two seconds Output frequency 0 to 320 Hz Frequency resolution 0 01 Hz Control Characteristics Control method Frequency control V f open loop sensorless vector control Switching frequency 1 310 amps FS4 9 default 6 kHz Frequency reference Analog input Resolution 0 1 10 bit accuracy 1 Panel reference Resolution 0 01 Hz Field weakening point 8 to 320 Hz Acceleration time 0 1 to 3000 seconds Deceleration time 0 1 to 3000 seconds Braking torque DC brake
316. nd B and 400W heater is installed in enclosures C and D Provided with CPT connected to load side of input disconnect SB Ice Cube Style Control Relay Provides misc user defined 4PDT control relay Requires user to define functionality Enclosure SE On Delay Timer Delay Make Provides misc user defined time delay relay Requires user to define functionality and time setting requirement Enclosure SF Off Delay Timer Delay on Break Provides misc user defined time delay relay Requires user to define functionality and time setting requirement Enclosure V6 T2 108 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Data and Specifications 9000 VFD Pump Panels Description Primary Design Features Type 12 IP54 or 38 Specification Adjustable Freguency Drives SVX9000 Drives Description Input Output Interface Features 2 4 NEMA Type 12 IP54 or NEMA Type 3R Specification 45 66 Hz input frequency Standard Setup adjustment provisions Output AC volts maximum Input voltage base Remote keypad display Standard Output frequency range 0 320 Hz Personal computer Standard Initial output current 16 25096 for 2 seconds Operator control provisions Overload 1 minute 19 1 150 110 Drive mounted keypad
317. ndamental 120V through 69 000V Harmonic Order Odd Harmonics Isc l h lt 11 11 lt h lt 17 17 h 23 23 lt lt 355 35 lt TDD lt 20 4 0 2 0 1 5 0 6 0 3 5 0 20 lt 50 7 0 35 2 5 1 0 0 5 8 0 50 lt 100 10 0 4 5 4 0 1 5 0 7 12 0 100 lt 1000 12 0 5 5 5 0 2 0 1 0 15 0 gt 1000 15 0 7 0 6 0 2 5 1 4 20 0 ratio Isc l is the ratio of the short circuit current available at the point of common coupling PCC to the maximum fundamental load current Consequently as the size of the user load decreases with respect to the size of the system the percentage of harmonic current that the user is allowed to inject into the utility system increases Notes TDD Total demand distortion is the harmonic current distortion in percent of the maximum demand load current 15 or 30 minute demand Maximum short circuit current at the not counting motor contribution Maximum demand load current for all of the connected loads fundamental frequency component at the PCC of the limits are measured at a point of common coupling CA08100007E May 2014 www eaton com Adjustable Frequency Drives One Line Diagram for Harmonic Analysis 2 7 9000 Drives Volts Volts Volts Volts Source A PCC Utility Side f Iu Utility Side Customer Transformer Transformer Volts Volts kVA ___ lsc lsc Impedance Impedance Customer AC Generator Motor Volts Generator
318. nds SPA205A0 4 9 170 6202 35 1250 500 3 85 0 4 H10 170M6277 3SHT 1250 1000 3 SPAH10A0 4 H13 170M6277 3SHT 1250 1000 3x3 Non Regenerative Front Ends SPN468A0 4 9 170M8547 3SHT 690 1250 3 Wiring Diagrams SPA9000 5 9000 SPI9000 Inverter Unit SPI9000 Inverter Unit Active Front End Regenerative Front End 4 8 719 2114 380 500 380 500 425 800 425 800 L1 L1 DC DC 12 L2 DC DC L3 L3 INU DC DC INU DC DC AFE NFE F1 F1 4 Fall F 1 K4 F4 L1 1 33 3 Wes L1 2 24 lt 2 A 11 mi U1 E R m PE UV Jw PE UV Jw F2 F2 425 600 Vdc 425 800 Vdc DC DC DC DC V6 T2 278 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 7 0 SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products Dimensions Approximate Dimensions in Inches mm SPA9000 SPN9000 SPI9000 Weight Frame Height Width Depth Lbs kg Active Front Ends F9 40 6 1030 9 4 239 14 6 372 148 67 FI10 40 6 1032 9 4 239 21 7 552 220 100 FI12 40 6
319. ng solution uses the Eaton H Max drive with Active Energy Control algorithm Built to be as tough as the application Eaton s robust design boasts an industrial grade enclosure and industry proven components e Industrial Power Supply XTContactors 22 mm Pilot Devices Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com H Max Series Drives Contents Description Page 5 vx ERE EDU x V6 T2 162 H Max IntelliPass and IntelliDisconnect Drives Catalog Number Selection 6 2 172 Product Selection V6 T2 173 Technical Data and Specifications V6 T2 181 Wiring Diagrams V6 T2 182 Dimensions V6 T2 184 Standards and Certifications Designed with Our Customers Product in Mind 61800 5 1 Removable top and bottom e ULBOSC entry panels cUL 4 OSHPD Seismic Certified display and keypad O e Easily accessible connection terminals with removable terminal connections Engineered Product Solution The Eaton H Max IntelliPass and IntelliDisconnect products are available with a variety of factory tested and certified options meeting or exceeding UL508C requirements 2 6 V6 T2 171 Adjustable Freguency Drives Series Drives 2 6 Catalog Number Selection Series IntelliPass and IntelliDisconnect Drives 01 3 4 N
320. nications The LonWorks Network Card OPTCA is used for connecting the 9000X Drive on a LonWorks network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a FTT 10A Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system According to 1509 11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay of nominal 5 as m 120 ohm line termination resistors required for installation Adjustable Frequency Drives CFX9000 Drives DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys N2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The 2 fieldbus is available as a factory installed option an
321. ocked see wiring diagram on Page V6 T2 245 RC Auto Transfer HOA Bypass Controller The manual HAND OFF AUTO HOA three contactor bypass option provides a means of bypassing the CPX9000 Bypass allowing the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of the load to across the line operation after a drive trip This option consists of an input a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in either mode IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 245 Door mounted pilot lights are provided that indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position RD Auto Transfer 108 Bypass Controller The auto INVERTER OFF BYPASS I0B three contactor bypass option provides a means of bypassing the 9000 Bypass allowing the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of th
322. oder 168 168A H13 1370A Communication Cards 205 205A H16 1640A Johnson Controls 2 261 261A 20 2060 _ Cl Modbus TCP 300 300A H23 2300A Voltage Rating C2 Modbus 690V 4 380 500V C3 PROFIBUS DP 5 520 690V C4 LonWorks 170 170A 590 590A 208 208A 650 650A 5 PROFIBUS DP 09 Connector 261 261A 750 750A C6 CANopen Slave 325 325A 820 820A C7 DeviceNet 385 385A H10 10304 Keypad C8 Modbus 09 Type Connector 416 416A H11 11804 Alphanumeric 01 Adapter 460 4604 13 13004 D2 Adapter 502 502A H15 15004 D3 RS 232 with 09 Connection Input Options 3 Three phase EMC T Board Modifications 7 DC Input 2 Varnished boards Brake Chopper Options brake chopper circuit B Internal brake chopper Note Brake chopper is only available in 480V CH3 drives V6 T2 252 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 09 LCX9000 Drives Product Selection LCX9000 Liquid Cooled 380 500 Vac Liquid Cooled Drives Drives Motor Output Current Thermal 1 A A ly kW Chassis Catalog Number 16 15 11 7 5 CH3 LCX016A0 4A3N2 22 20 15 11 CH3 LCX022A0 4A3N2 31 28 21 15 CH3 LCX031A0 4A3N2 38 35 25 18 5 CH3 LCX038A0 4A3N2 45 41 30 22 CH3 LCX045A0 4A3N2 61 55 41 30 CH3 LCX061A0 4A3N2 72 65 48 37 CH4 LCX072A0 4
323. og Value Objects AVOs to communicate drive parameters The card supports 9 6 19 2 and 38 4 Kbaud communication speeds and supports network addresses 1 to 127 Ethernet IP Network Communications The Ethernet IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet Industrial Protocol networks It includes an RJ 45 pluggable connector The interface uses CIP objects to communicate drive parameters CIP is Common Industrial Protocol the same protocol used by DeviceNet The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable by Static BOOTP and DHCP methods Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 9000 Drives Control Communication Option Descriptions For availability see Product Selection for base drive voltage required Available Control Communications Options 2 8 Option Option Description Type K1 Door Mounted Speed Potentiometer Provides the CPX9000 with the ability to adjust the frequency reference using door mounted potentiometer This option Control uses the 10 Vdc reference to generate a 0 10V signal at the analog voltage input signal terminal When the HOA bypass option is added the speed is controlled when the HOA switch is in the HAND position Without the HOA bypass option
324. om V6 T2 199 2 480V Drives CFX9000 Drive V6 T2 200 Adjustable Frequency Drives CFX9000 Drives CFX9000 Base Drive NEC Chassis UL Type 1 UL Type 12 and NEMA 12 Filtered UL Type 3R hp Current A Frame Base Catalog Number Base Catalog Number Base Catalog Number Low Overload Drive 74 2 11 FRA CFX00724BA CFX00734BA 10 14 FR5 CFX01024BA CFX01034BA 15 21 FR5 CFX01524BA CFX01534BA 20 27 FR5 2 CFX02024BA CFX02034BA 25 34 FR6 CFX02524BA 02534 30 40 FR6 CFX03024BA CFX03034BA 40 52 FR6 CFX04024BA CFX04034BA 50 65 FR7 CFX05014AA CFX05024AA CFX05034AA 60 77 FR7 CFX06014AA CFX06024AA CFX06034AA 75 96 FR7 CFX07514AA CFX07524AA CFX07534AA 100 124 FR8 CFX10014AA CFX10064AA CFX10034AA 125 156 FR8 CFX12514AA CFX12564AA CFX12534AA 150 180 FR8 CFX15014AA CFX15064AA CFX15034AA 200 240 FR9 CFX20014AA CFX20064AA CFX20034AA 250 302 FR9 CFX25014AA CFX25064AA CFX25034AA 300 361 FR10 CFX30014AA CFX30064AA 350 414 FR10 CFX35014AA CFX35064AA 400 477 FR10 CFX40014AA CFX40064AA High Overload Drive 1 1 2 11 FR5 CFX00724EA CFX00734EA 10 14 FR5 CFX01024EA CFX01034EA 15 21 FR5 CFX01524EA CFX01534EA 20 27 FR6 CFX02024EA CFX02034EA 25 34 FR6 CFX02524EA CFX02534EA 30 40 FR6 CFX03024EA CFX03034EA 40 52 FR7 CFX04014DA CFX04024DA CFX04034DA 50 65 FR7 CFX05014DA
325. om V6 T2 239 2 8 9000 Drives Adjustable Frequency Drives For availability see Product Selection for base drive voltage required Available Control Communications Options continued Option Option Description Type RA Manual HOA Bypass Controller The manual HAND OFF AUTO HOA three contactor bypass option provides a means of bypassing the CPX9000 allowing the Bypass AC motor to be operated at full speed directly from the AC supply line This option consists of an input HMCP a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in the inverter mode IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 245 RB Manual IOB Bypass Controller The manual INVERTER OFF BYPASS IOB three contactor bypass option provides a means of bypassing the CPX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line This option consists of an input HMCP a fused control power transformer and a full voltage bypass starter with a door mounted 10 selector switch IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interl
326. ommodates only power options input disconnect P1 and input line fuses P3 Bypass and other options require Size 9 Adding any standard control option will not require the larger enclosure 9 Consult factory Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 81 7 4 Adjustable Freguency Drives 5 9000 Drives Options 9000 Series Option Board Kits 9000 Series drives accommodate wide selection of adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes an A9 I O board and 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard Cards 6 DI 1 DO 2 Al TAO 1 10 ref 9 2 ext 24 Vdc EXT 24 2 RO NC NO B OPTA2 Extended Cards 2 RO therm SPX only B Encoder low volt 5V 15V 24V SPX only C 4 4
327. on Yes temperature Drive can operate at 12291 50 C see Pages V6 T2 164 and otor overload protection Yes V6 T2 165 tor stall protecti Y Storage temperature 40 to 158 F 40 to 70 C gt tor underload protection Relative humidity 0 to 95 RH noncondensing non corrosive no dripping water Short circuit protecti Air guality Chemical vapors IEC 60721 3 3 unit in operation Class 302 d T Mechanical particles IEC 60721 3 3 unit in operation Class 352 Surge protection Yes varistor input Altitude 100 load capacity no derating up to 3280 ft 1000m Conformed coated Yes prevents corrosion 196 derating for each 328 ft 100m above 3280 ft 1000mJ varnished boards max 9842 ft 3000m 380 480V Vibration FS4 FS9 EN 61800 5 1 EN 60068 2 6 5 to 150 Hz displacement amplitude 1 mm peak at 5 to 15 8 Hz max acceleration amplitude 1G at 15 8 to 150 Hz Shock EN 61800 5 1 EN 60068 2 27 UPS Drop test for applicable UPS weights Storage and shipping max 15G 11 ms in package Enclosure class EMA 1 IP21 or NEMA 12 IP54 keypad required for IP54 Type 12 Standards EMC mmunity Fulfills all EMC immunity requirements Emissions EN 61800 3 LEVEL H EMC C2 Emissions EMC level dependent EMC 2 EN61800 3 2004 Category C2 Delivered with Class C2 EMC filtering as default V6 T2 168 Volume 6 Solid State Motor Control 08100007
328. on resistors required for installation V6 T2 44 Volume 6 Solid State Motor Control DeviceNet Network Communications The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys 2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The N2 fieldbus is available as a factory installed option and as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The IP address of the board is configurable over Ethernet using a supplied software tool Adjustable Frequency Drives BACnet Network Communications The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It in
329. only the frequency converter is protected Overtemperature Yes protection Motor overload protection Yes Motor stall protection Yes Motor underload protection Yes Programmable Parameters Description Application macros basic pump fan and high load hoist Programmable start stop and reverse signal logic sinking or sourcing Reference scaling Programmable start and stop functions DC brake at start and stop Programmable V Hz curve Adjustable switching frequency Autorestart function after fault Protections and supervisions all fully programmable off warning fault Current signal input fault External fault Fieldbus communication Input frequency fin 50 60 Hz variation up to 45 66 Hz Connection to power Once per minute or less typical operation Output Ratings Output voltage 0 to Vin Continuous output Continuous rated current ly at ambient temperature max current 122 F 50 C overload 1 5 x ly max 1 min 10 min Output frequency 0 to 320 Hz Frequency resolution 0 01 Hz Initial output current lu Current 2 x lu for 2 seconds in every 20 second period Torque depends on motor Control Characteristics Control method Frequency control V Hz open loop sensorless vector control 1 5 to 16 kHz default 4 kHz Switching frequency Frequency reference Analog input resolution 0 1 10 bit accu
330. ons in Inches mm Type 1 1 21 and Type 12 IP54 with Flange Kit FR7 and FR8 gt H6 H4 gt H4 gt lt H5 gt Dia 1 ji e lt H2 gt lt H1 lt w3 gt gt lt lt H7 lt W1 gt m im 6 i o 5 01 L O ESA V lt H3 gt H12 lt gt i lt H9 gt lt H9 oh H10 gt lt gt 11 o o o o I 1i Opening W7 WS W6 FR7 FR8 Dia B o r Y PE H13 gt lt H8 gt W1 W2 W3 wa H1 H2 H3 H4 H5 H6 H7 D1 D2 Dia FR7 9 3 237 6 8 175 10 6 270 10 0 253 25 6 652 24 9 632 24 8 630 74189 7 4 189 0 9 23 0 8 20 10 1 257 45117 0 3 6 FR8 11 2 285 14 0 355 13 0 330 32 8 832 29 3 745 10 2 258 10 4 265 1 7 43 2 2 57 13 5 344 4 3 110 0 4 9 Flange Opening 7 FR8 w5 W6 w H8 H9 H10 H11 H12 H13 Dia FR7 9 2 233 6 9 175 10 0 253 244 619 741189 7 4 189 1 4 35 1 3 32 1 0 25 0 3 6 FR8 11 9 301 13 0 330 31 9 810 10 2 258 10 4 265 1 3 33 0 4 9 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 149 2 5 Adjustable Freguency Drives 9000 Drives Approximate Dimensions in Inches mm
331. oor mounted pilot lights are provided which indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position RD Auto Transfer 108 Bypass Controller The auto INVERTER OFF BYPASS I0B 3 contactor bypass option provides a means of bypassing the SVX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of the load to across the line operation after a drive trip This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter with a door mounted IOB selector switch For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked Door mounted pilot lights are provided which indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates whe
332. or 1 minute out of 10 minutes CFX9000 Enclosed Products Standard Enclosed covers a wide range of the most commonly ordered options Pre engineering eliminates the lead time normally associated with customer specific options Available configurations are listed on Pages V6 T2 195 to V6 T2 210 Modified Standard Enclosed applies to specific customer requirements that vary from the Standard Enclosed offering such as the need for an additional indicating light or minor modifications to drawings Contact your local sales office for assistance in pricing and lead time CA08100007E May 2014 www eaton com Custom Engineered for those applications with more unique or complex requirements these are individually engineered to the customer s needs Contact your local sales office for assistance in pricing and lead time Application Description Designed to meet the IEEE 519 1992 requirements for harmonic distortion the CFX9000 is an excellent What Are Harmonics Adjustable Frequency Drives choice for small and midsize drives applications where harmonics are a concern Take a perfect wave with a fundamental frequency of 60 Hz which is close to what is supplied by the power company Perfect Wave Volts v f x sin x Time t Add a second wave that is five times the fundamental frequency 300 Hz typical of frequency added to the line by a fluorescent light
333. or Cable Mounting Holes Entry For aces gt lt gt Cable D Entry N A For Cable For Cable m d Entry L Entry A For Cable P Entry Y Y K sj iwi U Y i j nah I Top View Bottom View LL Bottom View NEMA Type 1 IP21 NEMA Type 12 IP54 with Floor Stand For reference only dimensions are subject to change Wide High Deep Mounting Door Height Min Air Space A B D D1 E E1 F G G1 H J K 26 4 669 36 914 16 3 414 24 8 630 34 0 864 32 4 822 4 0 102 3 0 76 Cable Entry Door Clearance CB Handle Shipping Weight L M N P R s T U w Lbs kg 11 0 279 6 0 152 9 0 229 10 0 254 6 5 165 26 4 669 1 5 38 4 3 108 230 104 Stand X Y 2 BB CC DD EE FF GG HH JJ KK LL MM NN PP RR ss TT UU VV 56 0 43 11 1 1 8 0 8 55 2 260 35 5 5 3 0 6 0 2 0 5 4 1 1 8 8 5 4 1422 108 281 46 19 1402 660 90 141 76 152 51 136 28 224 137 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 89 2 4 Approximate Dimensions Inches mm Size 2 2 50 63 5 Lifting Holes k 2 Places J A RE o q H F dj YL jJ z lt 0 44 11 2 Mounting Holes 4 Places NEMA Type 1 IP21 NEMA Type 12 IP54 NEMA Type 12 IP54 Includes
334. osure style 0 chassis 690V drives 200 hp All 575V drives come standard without 480V drives 250 hp l and larger avai enclosure style 0 chassis Factory promise delivery Consult sales offi brake chopper option N N ce for availability Volume 6 Solid State Motor Control 480V drives 250 hp IH or larger are available drives 200 hp IH or larger are only available arger come standard with brake chopper option arger come standard with brake chopper option and larger are available with CA08100007E May 2014 www eaton com V6 T2 37 2 4 Adjustable Freguency Drives 5 9000 Drives Product Selection 230V SVX9000 Drives SVX9000 Open Drives e BU 5 V6 T2 38 208 240V NEMA Type 1 IP21 Drives Frame Size hp ly Current ly hp lj Current I Catalog Number FR4 3 4 3 7 1 4 8 SVXF07A1 2A1B1 1 4 8 1 1 2 6 6 SVX001A1 2A1B1 1 1 2 6 6 2 7 8 SVXF15A1 2A1B1 2 7 8 3 11 SVX002A1 2A1B1 3 11 12 5 SVX003A1 2A1B1 FR5 a 12 5 5 17 5 SVX004A1 2A1B1 5 17 5 7 1 2 25 SVX005A1 2A1B1 7 1 2 25 10 31 SVX007A1 2A1B1 FR6 10 31 15 48 SVX010A1 2A1B1 15 48 20 61 SVX015A1 2A1B1 FR7 20 61 25 75 SVX020A1 2A1N1 25 75 30 88 SVX025A1 2A1N1 30 88 40 114 SVX030A1 2A1N1 FR8 40 114 50 140 SVX040A1 2A1N1 50 140 60 170 SVX050A1 2A1N1 60 170 75 205 SVX060A1 2A1N1 FR9 75 205 100 261 SVX
335. ote keypad is included as the standard control panel Some options are voltage and or horsepower specific Consult your Eaton representative for details V6 T2 228 See Pages V6 T2 239 and V6 T2 240 for complete descriptions Includes local remote speed reference switch See Pages V6 T2 237 and 6 2 238 for complete descriptions Consult Eaton for availability Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Product Selection When 0rdering Select a base catalog number that meets the application requirements nominal horsepower voltage and enclosure rating The enclosed drive s continuous output amp rating should be equal to or greater than the motor s full load amp rating The base enclosed package includes a standard drive door mounted alphanumeric panel and enclosure Adjustable Frequency Drives The CPX9000 product uses the term High Overload lp in place of the term Constant Torque CT Likewise Low Overload is used in place of the term Variable Torque VT The new terms are a more precise description of the rating The older terms included ambient temperature ratings in addition to overload ratings In order to minimize enclosure size and offer the highest ambient temperature 9000 Drives rating overload and temperature ratings are now treated separately Ambient temperature ratings are shown in the table below Consult the factor
336. otential Include LOC REM key to choose control location Keypad Remote Mounting Kit This option is used to remote mount the SVX9000 keypad The OPTRMT KIT 9000X footprint is compatible to the SV9000 remote mount kit Includes 10 ft cable keypad holder and mounting hardware Miscellaneous Options Description Catalog Number 9000XDrive A PC based tool for controlling and monitoring of the SVX9000 Features include loading parameters that 9000XDRIVE can be saved to a file or printed setting references starting and stopping the motor monitoring signals in graphical or text form and real time display To avoid damage to the drive or computer SVDrivecable must be used SVDrivecable ft 1 8m RS 232 cable 22 gauge with a 7 pin connector on each end Should be used in conjunction SVDRIVECABLE with the 9000XDrive option to avoid damage to the SVX9000 or computer The same cable can be used for downloading specialized applications to the drive External Dynamic Braking Resistors Used with the dynamic braking chopper circuit to absorb motor regenerative See Page V6 T2 46 energy for stopping the load and to dissipate the energy flowing back into the drive Resistors are separated into standard duty and heavy duty Standard duty is defined as 20 duty or less with 10096 braking torque while heavy duty is defined as 5096 duty or less with 15096 braking torque Volume 6 Solid State Motor Control CA08100007E May 2014
337. pad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan AC 1 01080 01080 01080 Fan fuse 2 PP20202 PP20202 PP20202 Starting 1 00465 00465 00465 Fan driver board 1 VB00899 VB00399 VB00299 Isolation transformer fan 1 PP09056 PP09055 PP09055 Main DC fan DC fan 1 PP00072 PP00072 PP00072 DC power supply 1 01017 01017 01017 Other Front cover power 1 809012 809012 809012 Front cover connection 1 FR09013 FR09013 FR09013 Front power conduit 1 FR09014 FR09014 FR09014 Notes Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 138 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives 10 5 Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 1 S00451 00451 ASIC board 1 00457 00457 Control ASIC fan 1 PP01096 01096 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Power module 1 FR10 0385 4 ANV FR10 0261 5 ANV 1 FR10 0460 4 ANV FR1
338. perature protection Yes Altitude 100 load capacity no derating up to 3280 ft 1000m 1 derating for each 328 ft 100m above 3280 ft 1000m otor overload protection Yes max 9842 ft 3000m 380 480V otor stall protection Yes Vibration FS4 FS7 IEC 60068 2 6 10 150 Hz otor underload protection Yes Displacement amplitude 1 mm peak to peak from 10 15 8 Hz Max acceleration amplitude 1G peak from 15 8 150 Hz Short circuit protection Yes Shock FS4 FS7 IEC 60068 2 27 15G peak acceleration at 11 ms Surge protection Yes varistor input duration 1 2 sine ISTA 1A Certified Enclosure class NEMA Type 1 21 or NEMA Type 12 IP54 keypad required for 54 12 Volume 6 Solid State Motor Control Conformed coated varnished board Yes prevents corrosion CA08100007E May 2014 www eaton com V6 T2 181 2 6 Adjustable Freguency Drives Series Drives Wiring Diagrams Control Input Output PID Application BACnet IP Ethernet Industrial Protocol 1 RJ 45 Modbus TCPTransmission Control Protocol Ethernet Based DB FA Optional Optional Chopper R 1 Resistor LLL 5 DC Link a s Circuit a 2 put R Three Phas
339. phase motors are the only motors recommended for use in the majority of applications but other types of motors are occasionally used If the existing motor used in the application or the motor proposed for use with the drive system is a type other than NEMA Design A or B Application Engineering assistance must be requested to make certain that the drive is properly applied V6 T2 33 2 4 5 9000 Drives Product Selection Guide Controller Selection The basic requirement of controller selection is to match the output current voltage and frequency capabilities of the controller with the requirements of the connected motor Output Current The controller must be selected and applied such that the average operating motor current and horsepower do not exceed the continuous current and horsepower ratings of the controller The intermittent operating current must not exceed the intermittent current rating of the controller Motor Protection Eaton adjustable frequency drives include electronic motor overload protection circuits that are designed to meet the requirements of NEC article 430 2 provided that only one motor is connected to the output of the controller Output Voltage and Frequency When they are shipped AF controllers are adjusted to provide a maximum output voltage and frequency equivalent to the input line voltage and frequency The controllers can be adjusted to operate above line freque
340. proximate Dimensions in Inches mm Enclosure Size F EJ 93 58 2376 9 Approximate Approximate Weight Shipping Weight H1 w wi D D1 Lbs kg Lbs kg 69 51 60 00 48 00 37 50 26 00 1700 771 1850 839 1765 60 1524 0 1219 2 952 5 660 4 V6 T2 118 Volume 6 Solid State Motor Control 08100007 2014 www eaton com Adjustable Freguency Drives 2 5 5 9000 Drives SPX9000 Drives Contents Description Page SPX9000 Drives Features and Benefits 6 2 120 Standards and Certifications 6 2 120 Catalog Number Selection 6 2 121 Product Selection V6 T2 122 Accessories V6 T2 127 23 ced nette V6 T2 128 Replacement Parts 6 2 135 Technical Data and Specifications V6 T2 144 Dimensions V6 T2 145 Product Description The SPX9000 Series The SPX9000 supports fast The Eaton family of drives Adjustable Frequency Drives drive to drive communication includes DA1 DC1 H Max from Eaton s Electrical Sector It also offers an integrated M Max SVX9000 and are specifically designed data logger functionality for SPX9000 9000X Series drive for high
341. psed time meter KO Power fault LED lights 22 mm 13 Freguency meter KS Green LED run light 22 mm LA MP 3000 relay with URTD KV Green LED stop light 22 mm LD 3000 relay with URTD and CTs KU Red LED run light 22 mm LE Red LED stop light 22 mm LF Red LED fault light 22 mm LG Enclosure Options Power on white LED light 22 mm LJ ai Sii Miscellaneous LED light 22 mm LU 10 00 Inch 254 0 mm Expansion 7 7 Control Options 57 Catalog 9 57 Description Number Suffix 10 7 Door mounted speed potentiometer K1 11 7 Door mounted speed potentiometer with selector switch K2 20 00 Inch 508 0 mm Expansion 3 15 psig follower K3 7 8 selector switch K4 8 8 MANUAL AUTO reference switch K5 9 S8 START STOP pushbuttons K6 10 S8 Type D2 control relay SD 11 8 On delay SE Space Heater Off delay relay SF 7 9 Additional terminal blocks 4 points SD 8 59 9 9 10 9 Control Options a Description Kata Suffix Plastic Nameplate Bypass test switch used with RA and RB KF d sN Inverter bypass pilot lights 12 8 SN 9 SN 10 SN 11 SN Note Requires customer supplied 115 Vac supply Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 241 2 8 Adjustable Frequency Drives CPX9000 Drives 208V and 230V Power Options 25 200 hp 208V and 230V Bypass Options 25 200 hp Catalog Catalog Descript
342. put frequency 0 320 Hz EC 721 3 3 unit in operation class 352 no conductive dust allowed No corrosive gases Drive efficiency gt 95 E Altitude Up to 1 000m 100 load capacity no derating Power factor displacement 0 96 Above 1 000m Derating of 1 per each 100m required Liquid coolant pressure 87 psi 6 bar maximum Vibration EN 50178 EN 60068 2 6 5 150 Hz Liquid coolant flow rate 1 3 to 7 9 gal min 5 to 30 liter min Displacement amplitude 0 25 mm peak at 3 31 Hz minimum depending on drive size ax acceleration amplitude 1G at 31 150 Hz Shock EN 50178 EN 60068 2 27 UPS drop test Liquid coolant fittings Standard quick connect NPT Operating ambient temperature 10 50 Storage temperature 40 70 Humidity 95 maximum non condensing Altitude 3300 ft 1000 m maximum without derating Enclosure IP00 Warranty Standard terms 3 years with certified start up Mains Connection Input voltage Vin 400 500 Vac 525 690 Vac 10 10 465 800 Vdc 640 1100 Vdc 0 0 Input frequency fin 45 66Hz Connection to mains Once per minute or less normal case Motor Connection Output voltage 0 Vin Continuous output current Rated current at nominal inflow cooling water temperature of 30 Overload 2 sec 20 sec Starting current Rated current at 2 sec 20 sec if output frequency 30 Hz and temperature of heatsink lt 149 F 65 C
343. quency Drives CFX9000 Drives 2 CFX9000 Enclosed Drives Contents Description Page CFX9000 Drives Application Description 6 2 189 Features and Benefits 6 2 195 Standards Certifications 6 2 195 Product Identification V6 T2 195 Catalog Number Selection V6 T2 196 Product Selection V6 T2 197 Options 6 2 204 Technical Data Specifications V6 T2 209 Wiring Diagram V6 T2 211 Dimensions V6 T2 212 Product Description The CFX9000 Clean Power Drives from Eaton s Electrical Sector use tuned passive filters to significantly reduce line harmonics at the drive input terminals The CFX9000 drive also delivers True Power Factor in addition to reducing harmonic distortion the CFX9000 drive prevents transformer overheating and overloading of breakers and feeders which enables the application of adjustable frequency drives on generators and other high impedance power systems V6 T2 188 Volume 6 Solid State Motor Control The 9000X family of drives includes HVX9000 SVX9000 SLX9000 and SPX9000 9000X Series drive ratings are rated for either high overload or low overload indicates 110 overload capacity for 1 minute out of 10 minutes indicates 150 overload capacity f
344. r Input Fusing Input Fusing 2 UT Optional 18 Pulse 18 Pulse Reduced Transformer Transformer Voltage Starter Pre charge Pre charge _ Complete Complete Contactor Contactor 6 Pulse 6 Pulse Diode Bridge Diode Bridge 9000X 9000 12 Pulse Drive Mechanical Interlock B utput um S ECK ypass Contactor M A Contactor 1 Overload Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 245 28 9000 Drives Dimensions Approximate Dimensions in Inches mm Enclosure Size 7 Adjustable Frequency Drives 25 150 hp and 25 125 lj 480V 25 100 hp I and 25 75 hp lj 575V 84 37 2143 0 90 00 2286 0 lt 1550 393 7 21 50 546 1 Side View Finish Enclosure ANSI 61 Gray light Material V6 T2 246 Enclosure and Backplate 12 ga 0 1046 Cold Rolled Steel Volume 6 Solid State Motor Control Exhaust 51 05 0 im A fee ga 10 00 508 Clearance at 90 254 0 Top View 4 00 101 6 Minimum Free Air Space Required KE o i With Circuit Breaker When Specified E Operator Elements 93 92 quM Handle 2385 6 A key lock optional
345. r Air quality Chemical vapors IEC 721 3 3 unit in operation class 3C2 Mechanical particles IEC 721 3 3 unit in operation class 352 Altitude 100 load capacity no derating up to 1000m 1 derating for each 100m above 1000m max 3000m Vibration 5 150 Hz EN50178 EN60068 2 6 Displacement amplitude 0 25 mm peak at 3 15 8 Hz Max acceleration amplitude 1G at 15 8 150 Hz Shock EN50178 EN60068 2 27 UPS Drop Test for applicable UPS weights Storage and shipping max 15G 11 ms in package Cooling capacity required Approximately 296 Cooling air required FR4 41 cfm FR6 250 cfm FR7 250 cfm FR8 383 cfm 9 677 cfm F110 824 cfm FI12 1648 cfm FI13 2472 cfm Unit enclosure class FR4 FR7 NEMA Type 1 1 21 FR8 FI9 FI14 chassis 00 EMC at fault settings Immunity Fulfill all EMC immunity requirements Safety Approvals CE UL cUL EN 61800 5 1 2003 see unit nameplate for more detailed approvals Control Connections Analog input voltage 0 10V 200 kohms 10V to 10V joystick control Resolution 0 1 accuracy 1 Analog input current 0 4 20 mA 250 ohms differential Digital inputs 6 positive or negative logic 18 30 Auxiliary voltage 24V 15 max 250 mA Output reference voltage 10V 3 max load 10 mA Analog output 0 4 20 mA RL max 500 ohms resolution 10 bits Accuracy 2
346. r controller Enclosure class P20 FS1 FS3 Skip frequencies a Notes Exception 115V single phase in 230V three phase out Only FS2 and 253 drives are equipped with brake chopper circuit Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com V6 T2 17 2 2 Adjustable Freguency Drives PowerXL DC1 DA1 Series Adjustable Frequency Drives Standards DA1 Series 1 0 Specifications e Digital inputs 011 015 programmable Digital relay and analog outputs are programmable Two outputs analog or Includes Five inputs three digital and two digital analog Analog inputs 4 20 mA 0 10V digital Two relay outputs RS 485 interface DA1 Series Interface Reliability Pretested components Computerized testing Final test with full load e Conformal coated boards Eaton s Electrical Services amp Systems national network of AF drive specialists Terminal Signal Factory Preset Description 1 24Vdc Control voltage for 011 015 Maximum load 100 mA Reference potential V 2 DI Digital Input 1 Start Enable FWD 8 to 30V High Ry gt 6 3 012 Digital Input 2 Start Enable REV 8 to 30V High Ry gt 6 4 013 Digital Input 3 Fixed frequency FF1 FF2 8 to 30V High R4 gt 6 5
347. r Control CA08100007E May 2014 www eaton com V6 T2 43 2 4 5 9000 Drives Modbus Network Communications The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Communications The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a 10 Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system According to 15011898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms and specific line delay of nominal 5 nS m 120 ohms line terminati
348. r motors must be used Motors running across the line that are connected on polluted power distribution grids can overheat or operate at lower efficiency due to harmonics Higher installation costs Transformers and power equipment must be oversized to accommodate the loss of efficiencies This is due to the harmonic currents circulating through the distribution without performing useful work Adjustable Freguency Drives How Does a VFD Convert Three Phase AC to a Variable Output Voltage and Frequency The six pulse VFD The majority of all conventional drives that are built consist of a six pulse configuration The figure below represents a six diode rectifier design that converts three phase utility power to DC The inverter section uses IGBTs to convert DC power to a simulated AC sine wave that can vary in frequency from 0 320 Hz Six Diode Rectifier Design Six Pulse Diode Bridge Rectifier Converter Section 12 LIA L3A Inverter Section DC The six pulse VFD drive creates harmonic current distortion The harmonic current that is created is energy that can not be used by customers and causes external heat and losses to all components including other drives that are on the same power distribution See the curve below showing a 500 hp drive with 167A of damaging harmonic current Dynamic Braking Transistor Capacitors Output Transistors
349. r to Protected Chassis 20 except power terminals are protected by plastic shielding only Primarily intended to be mounted inside a surrounding protective enclosure NEMA Type 3R Similar in design to NEMA Type 12 IP54 except with more stringent design and test requirements Motor Protection Adjustable Freguency Drives DV DT Peak Motor Voltage Solutions Today s AFD products offer significantly improved performance but at the potential cost of motor insulation stress The fast switching time of the IGBT devices used in newer AFDs can cause a transmission line effect in the output power leads to the motor leading to possibly damaging voltage levels To meet this need NEMA has introduced a motor in MG1 Part 31 which provides an insulation system designed to maintain normal motor life in AFD applications For existing motors a motor protection scheme is required for longer cable runs Eaton offers three standard solutions for existing systems e MotoRx This solution provides an energy recovery system which clamps the peak motor voltage to a safe level for standard motors This option is used when the distance between a single motor and the drive is 600 ft or less Output Line Reactor This option provides an output line reactor reducing the DV DT of the AFD output voltage and lessening the transmission line effect to lower the peak voltage at the motor terminals Volume 6 Solid
350. racy 1 V Hz Panel reference resolution 0 01 Hz Field weakening point 3010320 Hz Acceleration time 0 to 3000 sec Deceleration time 0 to 3000 sec Braking torque DC brake 30 x T without brake option Brake Resistor Minimum Values 2 230V Series FS2 35 ohms and FS3 26 ohms FS4 14 ohms FS5 9 ohms 400V Series FS2 75 ohms and FS3 54 ohms FS4 28 ohms 55 17 ohms 575V Series FS3 103 ohms Ambient Conditions 14 F 10 C no frost to 122 F 50 C Rated loadability In Ambient operating temperature Storage temperature 40 F 40 to 158 F 70 C Eight preset speeds Relative humidity 0 to 95 RH noncondensing non corrosive no dripping water Analog input range selection signal scaling and filtering Air quality Chemical vapors IEC 721 3 3 unit in operation Class 302 Mechanical PID controller particles IEC 721 3 3 unit in operation Class 352 Skip frequencies Altitude 00 load capacity no derating up to 3280 ft 1000m derating for each 328 ft 100m above 3280 ft 1000m max 6560 ft 2000m Vibration EN 60068 2 6 3 to 150 Hz displacement amplitude 1 mm peak at 3 to 5 8 Hz max acceleration amplitude 1G at 15 8 to 150 Hz Shock EN 50178 IEC 68 2 27 UPS Drop test for applicable UPS weights storage and shipping max 156 11 ms in package Enclosure class IP20 FS1 FS3 IP21 FS4 and FS5 Notes Volume 6 Solid State Motor Control CA08
351. rame Base Catalog Size hp Size Number 2 Size Number 2 Low Overload Drive and Enclosure A 3 4 4 SVXF072KBP 4 SVXF073KBP 1 SVX0012KBP SVX0013KBP 2 SVX0022KBP SVX0023KBP 3 SVX0032KBP SVX0033KBP 5 5 SVX0052KBP 5 SVX0053KBP 7 1 2 SVX0072KBP SVX0073KBP 10 SVX0102KBP SVX0103KBP 15 6 SVX0152KBP 6 SVX0153KBP 20 SVX0202KBP SVX0203KBP B 25 7 SVX0252KAP 7 SVX0253KAP 30 SVX0302KAP SVX0303KAP 40 8 SVX0402KAP 8 SVX0403KAP 50 SVX0502KAP SVX0503KAP 60 SVX0602KAP SVX0603KAP Notes Enclosure dimensions starting on Page V6 T2 112 Includes drive local remote keypad and enclosure Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 105 7 4 Adjustable Freguency Drives 5 9000 Drives Options 9000 Series Option Board Kits 9000 Series drives accommodate wide selection of adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes an A9 I O board and 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Nu
352. reference to generate 0 10V signal at the analog voltage input signal terminal When the bypass option is added the speed is controlled when the switch is in the HAND position Without the bypass option a two position switch labeled local remote is provided on the keypad to select speed reference from the Speed Potentiometer or a remote speed signal K2 Door Mounted Speed Potentiometer with HOA Selector Switch Provides the SVX9000 with the ability to start stop and adjust the speed reference from Contro door mounted control devices or remotely from customer supplied inputs In HAND position the drive will start and the speed is controlled by the door mounted speed potentiometer The drive will be disabled in the OFF position When AUTO is selected the drive run and speed control commands are via user supplied dry contact and 4 20 mA signal 5 MANUAL AUTO Speed Reference Switch Provides door mounted selector switch for MANUAL AUTO speed reference Control START and STOP Pushbuttons 22 mm START green STOP red Provide door mounted START and STOP pushbuttons for either bypass Control non bypass configurations 9 2 Factory Installed Auxiliary Contacts Provide two NO NC auxiliary contacts Power 12 Bypass Pilot Lights for and RB Bypass Options A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber Addl bypass MOTOR ON BYPASS light indicates when the mo
353. rives SPX9000 Drives Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fan O 1 PP01086 01086 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Converter Power board 1 VB00308 0004 2 VB00208 0003 5 1 VB00308 0007 2 VB00208 0004 5 1 VB00308 0008 2 VB00208 0005 5 1 VB00208 0007 5 1 VB00208 0009 5 1 VB00410 0012 5 ARV Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main fan DC fan main 1 PP01060 PP01060 Other Mounting kit fixing kit 1 FR00040 FR00040 Mounting kit fixing kit N12 0 1 FR00079 FR00079 Control cover plastic N1 1 FR00006 FR00006 FR5 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control fan NEMA 12 control fano 1 PP01088 PP01088 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Converter Power board 1 VB00313 0017 2 VB00213 0016 5 1 VB00313 0025 2 VB00213 0022 5 1 VB00313 0031 2 VB00213 0031 5 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM M
354. rol panel internal drive functions and fieldbus if necessary Brake chopper standard from 1 30 hp 380 500V 3 4 15 hp 208 230V NEMA Type 1 IP21 and NEMA Type 12 IP54 enclosures available Frame Sizes FRA FR9 Open chassis FR10 and greater Standard option board configuration includes an A9 I O board and an A2 relay output board installed in slots A and B Standards and Certifications Product IEC 61800 2 Catalog Number Selection SVX9000 Adjustable Frequency Drives SVX 010 A 1 4 Product Family SVX drives Adjustable Frequency Drives At Default Settings mmunity Fulfills all immunity requirements Emissions EN 61800 3 LEVEL H SPX Open drives FR10 and greater Horsepower Rating F07 3 4 hp 800 800 hp F15 1 1 2 hp 900 900 hp 007 7 1 2 hp H10 1000 hp 010 10 hp H12 1200 hp 050 50 hp H13 1350 hp 125 125 hp H15 1500 hp 350 350 hp H16 1600 hp 700 700 hp H20 2000 hp AFD Software Series A Standard software A 1 2 4 SVX9000 Drives Safety UL508C CE u CE Board Modifications 1 Standard boards 2 Conformal varnished coating Options Options appear in alphabetical order Extended 1 0 Card Options B1 6 DI 1 ext 24 Vdc EXT 24 B2 1 RO NC NO 1 RO NO 1 therm B4 1 Al mA isolated 2 AO mA isolated 1 ext 24 Vdc
355. rol power transformer and a full voltage bypass starter with a door mounted IOB selector switch IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 211 RC Auto Transfer HOA Bypass Controller The manual HAND OFF AUTO HOA three contactor bypass option provides a means of bypassing the CFX9000 Bypass allowing the AC motor to be operated at full speed directly from the AC supply line The circuitry provides an automatic transfer of the load to across the line operation after a drive trip This option consists of an input HMCP a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in either mode IEC type input bypass and input contactors are provided The contactors are mechanically and electrically interlocked see wiring diagram on Page V6 T2 211 Door mounted pilot lights are provided that indicate bypass or inverter operation A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode WARNING The motor may restart when the overcurrent relay is reset when operating in bypass unless the IOB selector switch is turned to the OFF position RD Auto Transfer 108 Bypass Controller The auto INVERTER OFF BYPASS IOB three conta
356. s Frequency accuracy Digital 0 01 of max frequency Analog 0 2 of max frequency Undervoltage carryover limit 0 3 to 25 seconds Motor Performance Motor control V Hz Constant torque Standard Speed regulation 0 596 of base speed I O Terminal Block Description Specification One input 0 10 Vdc 4 20 mA Potentiometer 1 kohm to 2 kohm Analog voltage Nominal 10 Vdc 10 kohm input impedance Analog current Nominal 4 20 mA 250 ohm Analog inputs Input Power Digital inputs Four programmable inputs Voltage at 50 60 Hz 3 Hz 100V 120V 10 10 single phase 200V 240V 10 5 single phase 200V 240V 10 5 three phase Displacement power factor Better than 0 95 Efficiency Typically greater than 95 Design Type Microprocessor 32 bit Converter type Diode Inverter type Insulated gate bipolar transistor Waveform PWM Volts Hertz Environment Operating temperature 10 to 40 Digital outputs One Form A relay contact Programmable Parameters Description Specification Out of the box Factory settings loaded for quick start up Accel and decel 2 separately adjustable Linear or S Curve times 0 1 600 seconds DC injection braking External fault Terminal input Jog Terminal input Fault reset STOP RESET or terminal input 0 NO NC selectable
357. s 2 programmable Form C relay outputs switching capacity 24 Vdc 8A 250 Vac 8A 125 Vdc 0 4A Protections Overcurrent protection rip limit 4 0 x Ih instantaneously Overvoltage protection Yes Undervoltage protection Yes Earth fault protection ncase of earth fault in motor or motor cable only the requency converter is protected Switching frequency Adjustable with parameter 2 6 9 nput phase supervision Trips if any of the input phases are missing Frame 4 6 1 to 16 kHz default 10 kHz otor phase supervision rips if any of the output phases are missing Frame 7 12 1 to 10 kHz default 3 6 kHz Overtemperature protection Yes Frequency reference Analog input Resolution 0 1 10 bit accuracy 1 V Hz otor overload protection Yes Panel reference Resolution 0 01 Hz otor stall protection Yes Field weakening point 30 to 320 Hz otor underload protection Yes Acceleration time 0 to 3000 sec Short circuit protection Yes 424V and 10V reference voltages Deceleration time 0 to 3000 sec Braking torque DC brake 30 x T without brake option Ambient Conditions Ambient operating 14 F 10 C no frost to 122 F 50 C FRA FR9 temperature 14 F 10 C no frost to 104 F 40 C FR10 and up 14 F 10 no frost to 104 F 40 C all frames Storage temperature 40 to 158 F 40 to 70 C Relative humidity
358. s starting on Page V6 T2 88 Includes drive local remote keypad and enclosure These units are current rated 75 hp 205 amps 100 lj hp 261 amps They do not meet NEC ampere ratings Volume 6 Solid State Motor Control 208V Drives SVX9000Enclosei Nput Base Drives Drives Type 1 21 Type 12 IP54 Enclosure Frame Base Catalog Frame Base Catalog Size hp Current A Size Number Size Number High Overload Drive and Enclosure 0 3 4 3 7 4 SVXF0711EA 4 SVXF0721EA SVXODIIIEA SVX00121EA 1 12 66 SVXFIBHEA SVXFIGZIEA 22078000 SVXO02Z11EA 0 SVX00221EA 3 M SVXO0311EA SVX00321EA 5 175 5 SVX00511EA 5 SVX00521EA 142 25 SVXOO711EA SVX00721EA 1 10 31 6 SVX01011EA 6 SVX01021EA 180048000 SVXOISIIEA 00 SVX01521EA 2 20 61 7 SVX02011DA 7 SVX02021DA 2 058000 SVX02511DA 0 SVX02521DA 2680080 SVX03011DA SVX03021DA 3 40 114 8 SVX04011DA 8 SVX04021DA 4 50 143 8 SVX05011DA 8 SVX05021DA 5 60 170 8 SVX06011DA 8 SVX06021DA 75 211 9 SVX07511DA 9 SVX07521DA 278 SVX10011DA SVX10021DA 0 Low Overload Drive and Enclosure 0 1 4 8 4 SVX00111BA 4 SVX00121BA 1 1 2 6 6 SVXF1511BA SVXF1521BA 2 78 SVX00211BA SVX00221BA 3 11 SVX00311BA SVX00321BA 5 17 5 5 SVX00511BA 5 SVX00521BA 74 2 25 SVX00711BA SVX00721BA 10 31 SVX01011BA SVX01021BA 1 15 48 6 SVX01511BA 6 SVX01521BA 20 61 SVX02011BA SVX02021BA 2 25 75 7 SVX02511AA 7 SVX02521AA 30 88 SVX03011AA SVX03021AA 40 114 SVX04
359. scription Catalog Number 9000X demo drive 9000XDEMO NEMA Type 12 IP54 Conversion Kit The Type 12 54 kit kit consists of a metal option is used to convert a drive shroud fan kit for NEMA Type 1 IP21 to a some frames adaptor plate NEMA Type 12 IP54 drive and plugs The NEMA Type 12 IP54 NEMA Type 12 IP54 Conversion Kit Approximate Dimensions in Inches mm Approximate Frame Size Delivery Code Length Width Height Weight Lb kg Catalog Number FR4 w 13 330 7 178 4 102 4 1 8 OPTN12FR4 FR5 16 406 8 203 7 178 5 2 3 OPTN12FR5 FR6 21 533 10 254 5 127 7 3 2 OPTN12FR6 Flange Kits Flange Kit NEMA Type 12 1 54 Flange kits for Flange Kit NEMA 12 The flange kit is utilized when 12 1 54 enclosure drive rating IP54 Frames 4 9 the power section is mounted are determined by rating of Frame Delivery Catalog through the back panel of an drive Size Code Number enclosure Includes flange Flange Kit NEMA Type 12 ES OPTRA mount brackets and NEMA zi MENS Type 12 1 54 fan IP54 Frames 4 5 and 6 FR5 5 components shroud FRE OPTTHR6 not included ode umber m o FRA w OPTTHRFR4 FR8 OPTTHR8 FR5 OPTTHRFR5 M FR9 OPTTHR9 FR6 OPTTHRFR6 Note For installation of an SVX9000 NEMA Type 1 IP21 drive into a NEMA Type 12 IP54 oversized enclos
360. se protection Standard 0 10 Vdc signals Configurable w jumpers Overtemperature protection Standard 4 20 mA DC signals Standard DC overvoltage protection Standard Isolated signals Optional Drive overload protection Standard Discrete outputs Motor overload protection Standard Fault alarm Standard Programmer software Optional Drive running Standard Local remote keypad Standard Drive at set speed Programmable Keypad lockout Standard Optional parameters 14 Fault alarm output Standard Dry contacts 2 relays Form C Built in diagnostics Standard Open collector outputs 1 Surge protective device Optional Additional discrete outputs Optiona Communications RS 232 Standard RS 422 485 Optiona DeviceNet Optiona Modbus RTU Optiona CANopen slave Optiona PROFIBUS DP Optiona Lonworks Optional Johnson Controls Metasys N2 Optiona EtherNet IP Modbus TCP Optiona BACnet Optiona Note Volume 6 Solid State Motor Control The filter is optional in FR10 CA08100007E May 2014 www eaton com V6 T2 209 2 7 9000 Drives 9000 Drives continued Description Specification Performance Features Adjustable Freguency Drives Standard Specifications Description Six digital input programmable Specification 24V 0 lt 10V 1 218VR gt 5 kohms Sensorless vector control Standard Volts hertz control Standard IR and slip compensation Standard Electronic reversing Standard Dynam
361. sions in Inches mm Chassis Size CH5 W1 raj WE 1 AJ Hm z 9 H1 H3 Top H amm U U jo To N sss R1 lt D1 I Front Side Weight Voltage Amps H1 H2 H3 D1 W1 W2 1 2 Lbs 380 500 168 261 21 77 1 30 19 88 10 39 9 69 3 94 7 87 0 51 88 40 553 0 33 0 505 0 264 0 246 100 0 200 0 13 0 Chassis Size CH61 WI R2 W2 N f Sy E O H1 De ZER H2 1 i Y m W3 lt D1 gt Right Side Front Left Side Weight Voltage Amps H1 H2 H3 D1 W1 W2 W3 R1 Dia R2 Dia Lbs kg 380 500 300 385 25 91 2 09 23 23 14 69 9 69 3 94 5 91 0 55 0 51 121 55 658 0 53 0 590 0 373 0 246 0 100 0 150 0 14 0 13 0 525 690 170 208 Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 263 2 9 Adjustable Frequency Drives LCX9000 Drives Approximate Dimensions in Inches mm sry Liquid Cooled Inverter Chassis Size CH62
362. solated signals Optional Overtemperature protection Standard Discrete outputs DC overvoltage protection Standard Fault alarm Standard Drive overload protection Standard Drive running Standard Motor overload protection Standard Drive at set speed Programmable Programmer software Optional Optional parameters 14 Local remote keypad Standard Dry contacts 1 2 relays Form C Keypad lockout Standard Open collector outputs 1 Fault alarm output Standard Additional discrete outputs Optiona Built in diagnostics Standard Communications 5 232 Standard RS 422 485 Optiona DeviceNet Optiona odbus RTU Optiona slave Optiona PROFIBUS DP Optiona Lonworks Optiona Johnson Controls Metasys N2 Optiona EtherNet IP Optiona odbus TCP Optiona BACnet Optiona V6 T2 86 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 9000X Enclosed Drives continued NEMA Type 1 IP21 or NEMA Type 12 IP54 Description pecification Performance Features SVX9000 Drives Standard Specifications Description Six digital input programmable Specification 24V 0 10V 1 218V gt 5 kohms 2 4 Sensorless vector control Standard Volts hertz control Standard IR and slip compensation Standard Electronic reversing Standard Dynamic braking Optional DC braking Standard PID setpoint controller Programmable Criti
363. stance in pricing and lead time V6 T2 221 28 9000 Drives Application Description Designed to exceed the IEEE 519 1992 requirements for harmonic distortion the CPX9000 is the clear choice What Are Harmonics for applications in the water wastewater HVAC industrial and process industries where harmonics are a concern Take a perfect wave with a fundamental frequency of 60 Hz which is close to what is supplied by the power company Perfect Wave Volts v f x sin x Time t Add a second wave that is five times the fundamental frequency 300 Hz typical of frequency added to the line by a fluorescent light Second Wave Volts v f x WAVAVACAY Time t Combine the two waves The result is a 60 Hz supply rich in fifth harmonics Resulting Supply Volts v f x sin x sinu Time V6 T2 222 Adjustable Frequency Drives What Causes Harmonics Harmonics are the result of nonlinear loads that convert AC line voltage to DC Examples of equipment that are non linear loads are listed below AC variable frequency drives DC drives e Fluorescence lighting computers UPS systems Industrial washing machines punch presses welders etc How Can Harmonics Due to VFDs Be Diminished By purchasing Eaton s 18 pulse CPX9000 drive that is guaranteed to meet IEEE Std 519
364. t lightthatindicatesa Ligh drive fault has occurred 12 Bypass Pilot Lights for RB RA Bypass Options A green light indicates when the motor is running in inverter mode and an amber light indicates when the motoris bypass running in bypass mode The lights are mounted on the enclosure door above the switches LE Red Run Pilot Light 22 mm Provides a red run pilot light that indicates the drive is running Ligh P1 Input Circuit Breaker High interrupting circuit breaker that provides a means of short circuit protection for the power cables between it and the CPX9000 and nput protection from high level ground faults on the power cable Allows a convenient means of disconnecting the CPX9000 from the line and the operating mechanism can be padlocked in the OFF position This is factory mounted in the enclosure Standard rating is 65 kAIC at 208 480V 100 kAIC is available as an option P3 Input Line Fuses Rated to 200 kAIC Provide high level fault protection of the drive input power circuit from the load side of the fuses to the input side of the power Input transistors This option consists of three 200 kA fuses which are factory mounted in the enclosure P7 MOV Surge Suppressor Provides a Metal Oxide Varistor MOV connected to the line side terminals and is designed to clip line side transients nput P8 TVSS Surge Protective Device with 50 kA Rating Provides transient voltage protection eliminating surges and spikes w
365. t number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 140 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com FR12 Spare Parts Adjustable Frequency Drives SPX9000 Drives Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 2 00451 00451 ASIC board 2 00457 00457 Star coupler 1 00593 00593 Control ASIC fan 2 01096 01096 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Converter Power module 1 FR12 0820 4 ANV FR12 0650 5 ANV 1 FR12 0920 4 ANV FR12 0750 5 ANV 1 FR12 1030 4 ANV FR12 0820 5 ANV Driver board 2 S00450 S00450 Driver adapter board 2 VB00330 VB00330 Shunt board 12 VB00498 VB00511 Covers Top cover 2 FR10340 FR10340 Side cover 4 FR10341 FR10341 DC section Balancing resistor 4 PP13027 PP13027 DC busbars kit right 0000005 0000005 Bus capacitor 24 00335 00336 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad D SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 2 FR10846 FR108
366. terminals and is designed to clip line side transients nput Rated for 100 000A PE Output Contactor Provides a means for positive disconnection of the drive output from the motor terminals The contactor coil is controlled by the drive s run or Output permissive logic NC and NO auxiliary contacts rated at 10A 600 Vac are provided for customer use Bypass option RA includes an output contactor as standard This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure RA Manual HOA Bypass Controller The Manual HAND OFF AUTO HOA 3 contactor bypass option provides a means of bypassing the SVX9000 allowing the AC Bypass motor to be operated at full speed directly from the AC supply line This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in the inverter mode For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked RB Manual IOB Bypass Controller The manual INVE
367. tes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 4 V6 T2 55 2 4 Adjustable Freguency Drives 5 9000 Drives FR13 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control ASIC board 1 00457 00457 ASIC assembly 1 60501030 60501030 Control ASIC fan 1 01096 01096 Control module SVX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 Converter Power module 2 3 FI13 1150 4 ANV FR13 1030 5 ANV 3 FI13 1300 4 ANV FR13 1180 5 ANV 3 FI13 1450 4 ANV FR13 920 5 ANV Driver board 3 00454 00454 Driver adapter board 2 VB00330 VB00330 Shunt board 18 VB00505 00516 18 VB00514 VB00517 18 VB00541 VB00547 Covers Top cover 3 FI10001 FI10001 Side cover 3 FI10003 FI10003 DC section Balancing resistor 6 PP13034 PP13034 Bus capacitor 36 00335 00336 DC busbars kit 3 113329 113329 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC
368. ting the 9000X Drive on a DeviceNet Network It includes a 5 08 mm pluggable connector Transfer method is via CAN using a two wire twisted shielded cable with two wire bus power cable and drain The baud rates used for communication include 125K baud 250K baud and 500K baud Johnson Controls Metasys N2 Network Communications The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys N2 network With this connection the drive can be controlled monitored and programmed from the Metasys system The N2 fieldbus is available as a factory installed option and as a field installable kit Modbus TCP Network Communications The Modbus TCP Network Card is used for connecting the 9000X Drive to Ethernet networks using Modbus protocol It includes an RJ 45 pluggable connector This interface provides a selection of standard and custom register values to communicate drive parameters The board supports 10 Mbps and 100 Mbps communication speeds The address of the board is configurable over Ethernet using a supplied software tool Adjustable Frequency Drives BACnet Network Communications The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks It includes a 5 08 mm pluggable connector Data transfer is Master Slave Token Passing MS TP RS 485 This interface uses a collection of 30 Binary Value Objects BVOs and 35 Anal
369. tive disconnection of the drive output from the motor terminals The contactor coil is controlled by the drive s run or Outpu permissive logic NC and NO auxiliary contacts rated at 10A 600 Vac are provided for customer use Bypass options RB and RA include an output contactor as standard This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure PF Output Filter 100 300 ft Used to reduce the transient voltage DV DT at the motor terminals The output filter is recommended for cable lengths exceeding 100 ft Outpu 30m with a drive of 3 hp and above for cable lengths of 33 ft 10m with a drive of 2 hp and below or for a drive rated at 525 690V This option is mounted in the enclosure and may be used in conjunction with a brake chopper circuit PG MotoRX 300 600 ft 1000 V pS DV DT Filter Used to reduce transient voltage DV DT and peak voltages at the motor terminals This option is comprised of a 0 5 Outpu line reactor followed by capacitive filtering and an energy recovery clamping circuit Unlike the output filter See option PF the MotoRx recovers most of the energy from the voltage peaks resulting in a lower voltage drop to the motor and therefore conserving power This option is used when the distance between a single motor and the drive is 300 600 ft 91 183m This option can not be used with the brake chopper circuit The output filter option PF should be investigated as an a
370. tor bridge is not available from Eaton Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 269 Adjustable Freguency Drives SPA9000 SPN9000 SPI9000 Common DC Bus Drive Products 2 10 Features Standard Features 5 19000 SPA SPN Feature FR4 6 7 FR8 FI9 FI14 FI9 FI14 Fi9 00 u IP21 Air cooling u nm Standard board Varnished board Alphanumeric keypad class T EN 61800 3 for IT networks u u u u Safety CE UL u nm Input choke x LCL filter integrated charging Integrated charging DC side Diode thyristor rectifier IGBT Standards and Certifications CE UL cUL EN 61800 5 1 2003 Ee Catalog Number Selection Active Front End SPA 205 A0 4A3N1 Product Family P Board Modifications SPA Active Front End 1 Standard boards 2 Varnished boards Current Rating 480V 575V Brake Chopper Options 205 205A 125 125A N No brake chopper circuit 385 385A 325 325A H10 11504 920 9204 Level 3 IT network Software Series Standard Keypad A Alphanumeric Enclosure Rating Voltage Rating 0 Chassis 4 4
371. tor is running in bypass mode The lights are mounted on the enclosure door above the switches LD Green STOP Light 22 mm Provides a green STOP light that indicates the drive is stopped Light LE Red RUN Pilot Light 22 mm Provides a red RUN pilot light that indicates the drive is running Light LU Misc Light 22 mm Provides a misc user defined pilot light User to define light function and color Light LW PTT Push To Test Light 22 mm Provides misc user defined PTT pilot light User to define light function and color Light P1 Input Circuit Breaker Provides a means of short circuit protection for the power cables between it and the SVX9000 and protection from high level ground faults on Input the power cable Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position This is factory mounted in the enclosure P3 Input Line Fuses Rated to 200 high level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the nput power transistors This option consists of three 200 kA fuses which are factory mounted in the enclosure P8 SPD 50 kA per Phase Provides a surge protection device SPD connected to the line side terminals and is designed to clip line side transients nput Rated for 50 000A PA SPD 100 kA per Phase Provides a surge protection device SPD connected to the line side
372. tput Option card must be installed in one of the slots listed for that card Slot indicated in bold is the preferred location 2 is a multi protocol option card V6 T2 82 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Modbus RTU Network Communications The Modbus Network Card 2 is used for connecting the 9000X Drive as a slave on a Modbus network The interface is connected by a 9 pin DSUB connector female and the baud rate ranges from 300 to 19200 baud Other communication parameters include an address range from 1 to 247 a parity of None Odd or Even and the stop bit is 1 PROFIBUS Network Communications The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS DP network The interface is connected by a 9 pin DSUB connector female The baud rates range from 9 6K baud to 12M baud and the addresses range from 1 to 127 LonWorks Network Communications The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network This interface uses Standard Network Variable Types SNVT as data types The channel connection is achieved using a 10 Free Topology transceiver via a single twisted transfer cable The communication speed with LonWorks is 78 kBits s CANopen Slave Communications The CANopen Slave Network Card OPTC6 is used for connecting the 9000X Drive to a host system
373. ts The CFX9000 Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The CFX9000 Series factory installed standard board configuration includes an A9 I O board and an 2 relay output board which are installed in slots A Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard Cards 2 RO NC NO B OPTA2 6 DI 1 DO 2 Al 1 1 10 ref A 9 2 ext 24 Vdc ext 24 Vdc Extended Cards 6D C D E OPTB1 B1 1 NC N0 1 NO 1 therm B C D E OPTB2 B2 1 Al mA isolated 2 AO mA isolated B C D E 0PTB4 4 u u u u 3 RO NO B C D E OPTB5 B5 3 Pt100 RTD board D E OPTB8 B8 1 RO NO 5 DI 42 240 Vac input C D E OPTB9 B9 Communication Cards Modbus D E OPTC2 cz u Modbus TCP D E nm BACnet D E u u EtherNet IP DE u nm Johnson Controls 2 D E OPTC2 CA
374. ulated gate bipolar transistors IGBTs which provide quiet motor operation high motor efficiency and smooth low speed performance The size and simplicity of the NFX9000 make it ideal for hassle free installation where size is a primary concern V6 T2 2 Volume 6 Solid State Motor Control Models rated at 240 volts single or three phase 50 60 Hz are available in sizes ranging from 1 4 to 2 hp Models rated at 115 volts single phase 50 60 Hz are available in the 1 4 to 1 2 hp size range The standard drive includes a digital display operating and programming keys on the keypad The display provides drive monitoring as well as adjustment and diagnostic information The keys are utilized for digital adjustment and programming of the drive as well as for operator control Separate terminal blocks for control and power wiring are provided for customer connections The drives feature RS 485 serial communications Adjustable Frequency Drives Contents Description Page NFX9000 Drives Catalog Number Selection V6 T2 3 Product Selection 6 2 3 Technical Data Specifications V6 T2 4 Wiring Diagrams V6 T2 5 Dimensions V6 T2 7 Features and Benefits NFX9000 Adjustable Frequency AC Drives Feature Customer Benefit V Hz control Provides 150 starting torque and advanced low speed control Clearl
375. ume 6 Solid State Motor Control 08100007 2014 www eaton com Line Reactors reactor carries out several functions in the liquid cooled drive Connection of the line reactor is necessary except if you have a component in your system that performs the same tasks e g a transformer The line Line Reactor Specifications Adjustable Frequency Drives LCX9000 Drives reactor is needed as an essential component for motor control to protect the input and DC link components against abrupt changes of current and voltage as well as to function as a protection against harmonics The line reactors are included in the standard delivery of liquid cooled drives not inverters However you can also order your drive without a line reactor Thermal Nominal Calculated Choke Drive Rating Drive Rating Current Inductance Loss Catalog Number 480V 690V A pH A B W 690 16 to 22 12 to 23A 23 1900 145 CHK0023N6A0 31 to 38A 31 to 38A 38 1100 170 CHK0038N6A0 45 to 46 to 62A 62 700 210 0062 6 0 721087 721087 87 480 250 0087 6 0 105 10 140 105 to 140 145 290 380 0145 6 0 168 10 261 170 to 261A 261 139 187 460 CHK0261N6A0 300 to 385A 325 to 385A 400 90 126 570 CHK0400N6A0 820 to 1180A 460 to 520A 416 to 502A 520 65 95 610 CHKO520N6A0 1370A 1300 to 1500A 590 to 650A 590 to 650A 650 51 71 840 0650 6 0 16404
376. unt board 36 VB00541 VB00516 36 VB00517 Covers Top cover 6 FI10001 FI10001 Side cover 6 FI10003 FI10003 DC section Balancing resistor 6 PP13034 PP13034 Bus capacitor 72 00335 00336 DC busbars kit 6 FI13329 FI13329 Inverter Rectifier module 2 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 2 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly left 6 FI13301 FI13301 Fan AC 6 01080 01080 Fan fuse 12 PP20202 PP20202 Starting 6 S00520 S00520 Fan driver board AC 6 VB00299 VB00299 solation transformer 6 PP10057 PP10057 Main DC fan DC fan 6 PP00072 00072 DC power supply 6 01017 01017 Notes Factory recommended parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com 2 4 V6 T2 57 2 4 Adjustable Frequency Drives SVX9000 Drives Technical Data and Specifications SVX9000 Drives Description Specification Input Ratings Description Specification Control Connections Input voltage Vin 10 15 Input frequency fin 50 60 Hz variation up to 45 66 Hz Connection to power Once per minute or less typical operation High withstand rating 100 Output Ratin
377. upply 1 01017 01017 01017 Other Front cover power 1 809012 809012 809012 Front cover connection 1 FR09013 FR09013 FR09013 Front power conduit 1 FR09014 FR09014 FR09014 Notes Factory recommended spare parts Select one part number based on the amperage rating of the drive Please contact EatonCare at 877 ETN CARE for assistance V6 T2 52 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives FR10 Spare Parts Quantity 230V 480V 575V Category Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 1 S00451 00451 ASIC board 1 00457 00457 Control ASIC fan 1 PP01096 PP01096 Control module SVX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 2 2 Power module 1 FR10 0385 4 ANV FR10 0261 5 ANV 1 FR10 0460 4 ANV FR10 0325 5 ANV 1 FR10 0520 4 ANV FR10 0385 5 ANV 1 FR10 0416 5 ANV Driver board 1 S00450 S00450 Driver adapter board 1 VB00330 VB00330 Shunt board 6 VB00497 VB00510 6 VB00498 VB00511 6 VB00537 VB00545 Covers Top cover 1 FR10340 FR10340 Side cover 2 FR10341 FR10341 DC section Balancing resistor 2 PP13027 PP13028 DC busbars kit
378. ure V6 T2 42 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives 2 4 SVX9000 Drives Options 9000X Series Option Board Kits The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs The drive s control unit is designed to accept a total of five option boards The 9000X Series factory installed standard board configuration includes A9 I O board and 2 relay output board which are installed in slots A and B Option Board Kits Option Boards Field Factory Installed Installed SVX Ready Programs Allowed Slot Catalog Option Local Option Kit Description Locations Number Designator Basic Remote Standard MSS PID Multi P PFC Standard I O Cards 6 DI 1 DO 2 Al TAO 1 10 ref 9 2 ext 24 Vdc EXT 24 2 RO NC NO B OPTA2 m m Extended Cards 2 RO therm SPX only B Encoder low volt 5V 15V 24V SPX only 4 4 Encoder high volt 15V 24V SPX only G OPTA5 A5 u Double encoder SPX only C OPTA7 7 u 6 DI 1 DO 2 Al 1 AO SPX only A OPTA8 A8 u 3 DI encoder 10 24V out 15V 2
379. usoidal waveforms available The CPX9000 drive also delivers True Power Factor in addition to reducing harmonic distortion the CPX9000 drive prevents upstream transformer overheating and overloading of breakers and feeders enabling the application of adjustable frequency drives on generators and other high impedance power systems All 9000X Series drives are constant torque rated and rated for either high overload or low overload lj indicates 15096 overload capacity for 1 minute out of 10 minutes indicates 11096 overload capacity for 1 minute out of 10 minutes Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com CPX9000 Enclosed Products Standard Enclosed covers a wide range of the most commonly ordered options Pre engineering eliminates the lead time normally associated with customer specific options Available configurations are listed on Pages V6 T2 228 and V6 T2 237 to V6 T2 242 Modified Standard Enclosed applies to specific customer requirements that vary from the Standard Enclosed offering such as the need for an additional indicating light or minor modifications to drawings Contact your local sales office for assistance in pricing and lead time Custom Engineered for those applications with more unique or complex requirements these are individually engineered to the customer s needs Contact your local sales office for assi
380. ustable Freguency Drives 2 4 SVX9000 Drives For availability see Product Selection for base drive voltage required Available Control Communications Options continued Option Description Option Type RA Manual Bypass Controller The manual HAND OFF AUTO HOA 3 contactor bypass option provides a means of bypassing the SVX9000 allowing the AC Bypass motor to be operated at full speed directly from the AC supply line This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter with a door mounted HOA selector switch and an INVERTER BYPASS switch The HOA switch provides the ability to start and stop the drive in the inverter mode For applications up to 100 hp a Freedom Series IEC input contactor a Freedom Series IEC output contactor and a Freedom Series IEC starter with a bimetallic overload relay is included For applications above 100 hp an Advantage input contactor an Advantage output contactor and an Advantage starter with electronic overload protection is included The contactors are mechanically and electrically interlocked RB Manual IOB Bypass Controller The manual INVERTER OFF BYPASS I0B 3 contactor bypass option provides a means of bypassing the SVX9000 allowing Bypass the AC motor to be operated at full speed directly from the AC supply line This option consists of an input disconnect a fused control power transformer and a full voltage bypass starter
381. utput frequency 0 to 500 Hz Frequency resolution 0 1 Hz Initial output current ly 200 for 45 for every 40 seconds Programmable Parameters Torque depends on motor Description Control Characteristics Built in Help card Operation mode U f control slip compensation sensorless vector control SLV 14 Standard operation parameters Ventor camtrol With feedback LAN Switching fi 4 to 32 Reference scaling witching frequency 0 7 Volt f 10 Vd 10 mA Programmable start and stop functions S ORA Field weakeni int Oto 500 H DC brake at start and stop Pe ee seg A Acceleration ti 0 1 to 600 d Programmable V Hz curve cceleration time 0 600 seconds Deceleration ti 0 1 10 600 d Adjustable switching frequency Se Brake Resistor Minimum Values 2 230V Series FS2 and FS3 15 ohms 400V Series FS2 33 ohms FS3 22 ohms Autorestart function after fault Protections and supervisions Power section fault indication Ambient Conditions External fault m Ambient operating 14 F 10 C no frost to 122 F 50 C Rated loadability ly Fieldbus communication temperature P20 NEMA 0 Safe torque off STO function Storage temperature 40 F 40 to 140 F 60 C Analog input range selection signal scaling and filtering Relative humidity 0 to 95 RH noncondensing non corrosive no dripping wate
382. ve or in storage Includes a thermostat for variable temperature Enclosure control A 200W heater is installed in enclosures 0 and 1 and a 400W heater is installed in enclosures 2 5 Includes a 115V supply to power heater Enclosed Drive Options SVX Conversion Kit Brake Chopper Options Frame 4 7 The brake chopper circuit option is used for applications that Frame Enclosure Delivery require dynamic braking Dynamic braking resistors are not Size Size Code Catalog Number included with drive purchase Consult Page V6 T2 46 for FRA 0 2810 OPTCON SVXFR4 SZ00 dynamic braking resistors which are supplied separately Resistors not UL Listed NS ch AE DT NEWA FR5 0 FB10 OPTCON SVXFR5 SZ00 or brake chopper circuit selection and adder A Type 1 IP21 NEMA Type 12 IP54 consult the factory NNP FR6 1 FB10 OPTCON SVXFR6 SZ01 2 OPTCON SVXFR6 SZ02 FR7 2 FB10 OPTCON SVXFR7 SZ02 Note The kit consists of a flange kit adapter plate s hardware remote keypad kit and SVX9000 decal Volume 6 Solid State Motor Control 08100007 2014 www eaton com V6 T2 85 7 4 Adjustable Freguency Drives 5 9000 Drives Technical Data and Specifications 9000 Enclosed Drives 1 IP21 or NEMA Type 12 IP54 NEMA Type 1 IP21 or NEMA Type 12 IP54 Description Specification Description Specification Primary Design Features Input Output Interface Features
383. vide assistance to answer any questions about the technical capabilities of Eaton drives Motor Selection The basic requirement of motor selection is to match the torque vs speed capability of the motor to the torque vs speed requirement of the driven load Volume 6 Solid State Motor Control 08100007 2014 www eaton com 2 4 SVX9000 Drives Contents Description SVX9000 Drives SVX9000 Open Drives SVX9000 Enclosed Drives SVX9000 VFD Pump Panels Motor Torque vs Speed Capability As the speed of a motor is reduced below its 60 Hz base speed motor cooling becomes less effective because of the reduced speed of the self cooling fan This limitation determines the maximum torque for continuous operation at any operating speed The maximum intermittent operating torque is determined by the motor s torque vs current characteristics and the output current capability of the adjustable frequency controller Multiple Motor Operation A number of motors can be connected in parallel to a single controller Since the frequency of the power supplied by the controller is the same for each motor the motors will always operate at the same speed Application Engineering assistance must be requested for all multiple motor applications to assure compliance with all controller design limitations Page V6 T2 36 V6 T2 75 V6 T2 99 Special Types of Motors Standard NEMA Designs A and B three
384. w With the SVX9000 Series Sensorless Vector Control Eaton s expanded Eaton drive offering now covers a complete line of PWM adjustable frequency speed drives in ratings from e 208V 3 4 to 100 hp ly 1 to 100 hp e 230V 3 to 100 hp ly 1 to 125 hp 480V 1 to 1900 hp 1 1 2 to 2200 hp 575V 2 to 2000 hp ly to 2300 hp The Eaton family of drives includes H Max M Max SVX9000 and SPX9000 9000X Series drive ratings are rated for either high overload ly or low overload indicates 11096 overload capacity for 1 minute out of 10 minutes IH indicates 15096 overload capacity for 1 minute out of 10 minutes A full range of enclosure types and options are available to meet a wide array of applications from simple variable torque to more complex industrial applications such as conveyors mixers and machine controls Application Description Application Engineering Proper selection and application of all drive system components is essential to assure that an adjustable frequency drive system will safely and reliably provide the performance required for any given application The party responsible for the overall design and operation of the facility must make sure that qualified personnel are employed to select all components of the drive system including appropriate safety devices Eaton s AF Drives Application Engineering Department is prepared to pro
385. www eaton com V6 T2 45 2 4 5 9000 Drives Open Drive Options Brake Chopper Options brake chopper circuit option is used for applications that require dynamic braking Dynamic braking resistors are not included with drive purchase Consult the factory for additional dynamic braking resistor selections that are supplied separately list of common resistors are listed below and are complete Duty Cycle The duty cycle rating is based on a 60 second period For example the 20 duty cycle resistor can carry 100 current for 12 seconds out of every 60 seconds while the 50 duty cycle resistor can carry 150 current for 30 seconds out of every 60 seconds Adjustable Frequency Drives Torgue If the braking torque required is less than 15 dynamic braking is not required because the regenerated energy will be dissipated in the drive and motor losses indoor assemblies include a pre wired terminal block and a thermal switch and are not UL Listed Dynamic Brake Resistor Catalog Number Selection DBR R100 W0800 Rated Watts 0800 800 Watts 8000 8000 Watts 080K 80 000 Watis Resistance 100 1 0 Ohms 100 100 Ohms Dynamic Brake Resistor 230V Brake Resistors 20 Duty 100 Torgue 50 Duty Cycle 150 Torque Drive hp Minimum CT ly
386. xclusive to H Max drives V6 T2 161 2 6 Series Drives Drives Drives Product Description Eaton s Series VFD has software and hardware designed specifically for the HVAC pump industry The ultra efficient DC capacitor and power structure allows the drive to consume less energy lowering greenhouse gases The I O configuration is designed with wiring ergonomics in mind by including removable terminal blocks The main easily removable control board used for all drive frames with six digital IN two analog IN one analog OUT three relay OUT accepts two additional or communication board In addition the control board has built in RS 485 and Ethernet communication These drives continue the tradition of robust performance and raise the bar on features and functionality ensuring the best solution at the right price In addition to the Active Energy Control Algorithm to maximize motor efficiency the drive boasts an ultra efficient DC capacitor and power structure to allow less energy consumption lowering greenhouse gases V6 T2 162 Volume 6 Solid State Motor Control Features and Benefits Hardware Thin metal capacitor design ultra efficient drive operation and extended self life up to five years without reforming Integrated 5 DC link choke with Input surge protection protects against voltage spikes and provides a cle
387. ximate Dimensions in Inches mm FR13 Open Chassis Inverter W4 W4 W4 W4 WA Dia 1 400 rie lt lt gt 4004 0 02 lt W1 ofe wi W W 27 87 531 708 150 677 26 65 4 57 3 35 116 85 w W H H H3 41 54 246 39 86 1055 62 5 1012 5 1050 20 553 13 16 50 4134 079 Dia 2 W2 w2 2 A D3 H5 DI 02 03 D4 21 77 0 51 0 63 1 97 05 1 06 27 Dia 3 Dia 2 0 35x0 59 0 18 07 08 1 5 91 9 64 150 244 8 9x15 4 6 Dia 3 0 51 13 Dia 4 0 37 9 5 Weight Lbs kg 683 310 Notes 9000X FR14 is built of two FR13 modules Please refer to SPX9000 installation manual for mounting instructions FR13 is built from an inverter module and a converter module Please refer to SPX9000 installation manual for mounting instructions V6 T2 70 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 4 SVX9000 Drives Approximate Dimensions in Inches mm FR13 Open Chassis Converter
388. ximum switching load 250 Vac 6A or 30 Vdc 5A 11 K14 Relay 1 normally open contact Active RUN Maximum switching load 250 Vac 6A or 30 Vdc 5A Note Programmable function lt lt 5 a i 4 gt gt M 3 s E 92 1 2 3 4 6 8 lt a sig 5 lt lt a zls 28 58 v L LA CPU V6 T2 16 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 2 PowerXL DC1 DA1 Series Adjustable Frequency Drives DA1 Series Ratings Specifications PowerXL DA1 Basic Controller IP20 Standard Ratings PowerXL DA1 Series Drives Description Specification Description Specification Protections Input Ratings Overload protection 150 for 60s for every 600 seconds Input voltage Vin 10 Overvoltage protection Yes Input frequency fin 50 60 Hz variation up to 48 62 Hz Undervoltage protection Yes Connection to power Maximum of one time every 30 seconds Ground fault protection Yes Output Ratings Overtemperature Yes Output voltage 0 to Vin protection Continuous output Continuous rated current In at ambient temperature max 122 F 50 C D Motor overload protection Yes current 150 for 60 seconds 200 for 4 seconds Motor stall protection Yes O
389. y Description Drive Catalog Number Catalog Number Catalog Number Control Fiber board 1 00451 00451 ASIC board 1 00457 00457 Control ASIC fan 1 PP01096 PP01096 Control module SPX control module 1 CPBS0000000000 CPBS0000000000 Standard slot A 1 0 card 1 9 9 Standard slot 1 0 card 1 OPTA2 OPTA2 Converter Power module 2 1 FR11 0590 4 ANV FR11 0460 5 ANV 1 FR11 0650 4 ANV FR11 0502 5 ANV 1 FR11 0730 4 ANV FR11 0590 5 ANV Driver board 1 S00452 00452 Driver adapter board 1 VB00330 VB00330 Shunt board 9 VB00513 VB00512 9 VB00514 VB00546 9 VB00538 VB00547 Covers Top cover 1 FR11345 FR11345 DC section Balancing resistor 3 PP13027 PP13027 DC busbars kit right 3 0000005 0000005 capacitor 18 00335 00335 Inverter Rectifier module 1 FR10823 FR10823 Diode 3 01177 01177 Rectifier board 1 00591 00591 Keypad SVX SPX keypad 1 KEYPAD LOC REM KEYPAD LOC REM Main AC fan Fan assembly right 3 10847 10847 3 01080 01080 Fan fuse 4 PP20202 PP20202 Starting 3 S00530 S00530 Fan driver board AC 3 VB00299 VB00299 Isolation transformer right 3 FR10845 FR10845 Main DC fan DC fan 2 00072 00072 DC power supply 2 801017 01017 Notes Factory recommended parts Select one par
390. y for 50 ratings of FR10 and above Ambient Temperature Ratings Frame Size ly 1 FR4 FR9 5026 5026 FR10 above 40 40 208 230V Drives 9000 Drive 9000 Base Drive 1 Enclosure Current Chassis Base Catalog Size hp O A Frame Number Low Overload Drive 7 25 75 FR7 CPX02512AA 30 88 FR7 CPX03012AA 40 114 FR7 CPX04012AA 50 140 05012 60 170 FR8 CPX06012AA 75 205 FR8 CPX07512AA 8 100 300 FR CPX10012AA 9 125 340 FR8T CPX12512AA 150 410 FR8T CPX15012AA 10 200 522 FROT CPX20012AA High Overload Drive 7 25 75 FR7 CPX02512DA 30 88 FR7 CPX03012DA 40 114 FR8 CPX04012DA 50 140 FR8 CPX05012DA 60 170 FR8 CPX06012DA 8 75 205 FR9 CPX07512DA 9 100 300 FR8T CPX10012DA 125 340 FR8T CPX12512DA 10 150 410 FR9T CPX15012DA 200 522 FR9T CPX20012DA Notes See enclosure dimensions beginning on Page V6 T2 246 hp ratings are provided as a guideline Drives should be sized per motor nameplate FLA The 18 pulse clean power assembly includes a standard drive door mounted local remote keypad and enclosure Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com f dynamic brake chopper or control communication option is desired change the appropriate code in the base catalog number All of the programming is exactly the same as the standard SVX9000 drive Sele
391. y laid out and easy to understand keypad with four character LED display four status indicating LEDs speed potentiometer and five function keys Most informative operator s interface in this class of VFD provided as standard All parameters diagnostic information and metering values are displayed with a bright four character LED display Provide enhanced application flexibility One analog input four programmable intelligent digital inputs one programmable relay Direct connection to serial communications networks Serial communication port RS 485 Single phase or three phase input Operate three phase motor with single phase capability on 115 240 Vac rated units supply Standards and Certifications NEMA IEEE NEC Design Standards UL Listed cUL Listed CE Marked 0 Listed Listed CA08100007E May 2014 www eaton com Adjustable Freguency Drives 2 1 9000 Drives Catalog Number Selection 9000 Drives Base Catalog Number Voltage 1 115 Vac 2 240 Vac Enclosure Horsepower 0 IP20 25 1 4 hp F50 1 2 hp n 001 1 hp Series 002 2 hp A Product Selection NFX9000 NFX9000 Basic Controller IP20 Input Ampere Description Single Three Continuous Output hp O Volts Phase Rating Ampere Rating Catalog Number PB 1 4 90 130 6 0 15 NFXF25A0 1 i 1 2 90
392. ypass Options 7 1 2 125 208V Power Options 7 1 2 100 m atalog Catalog Description Number Suffix Description Number Suffix Manual HOA bypass controller RA Input breaker P1 IOB bypass controller RB Input line fusing P2 Auto transfer bypass controller RC Input line fuses 200 kAIC P3 Auto transfer bypass controller RD Output contactor PE Single overload relay PH Reduced voltage starter for bypass RG Dual overload relays Dual overloads for bypass PN MOV P7 480 575 5 Options 7 1 2 400 hp 50 surge protective device 8 Catalog 100 surge protective device 9 Description Number Suffix 230V Power Options 7 1 2 125 hp Manual HOA bypass controller RA Catalog 1 bypass controller RB Description Number Suffix Auto transfer bypass controller RC Input breaker P1 Auto transfer IOB bypass controller RD Input line fusing P2 Reduced voltage starter for bypass RG Input line fuses 200 kAIC P3 Output contactor PE Dual overloads for bypass PN Single overload relay PH Note Dual overload relays PI Requires customer supplied 115 Vac supply MOV P7 50 kA surge protective device P8 V6 T2 208 Volume 6 Solid State Motor Control CA08100007E May 2014 www eaton com Adjustable Frequency Drives CFX9000 Drives 2 7 Technical Data and Specifications CFX9000 Drives Description Specification Primary Design Features Description Speci
Download Pdf Manuals
Related Search
Related Contents
Installation Manual FP-570T User Manual DE-7200 Centrifuge Variable Frequency Drive Charenton magazine n°152 juin 2010 Copyright © All rights reserved.