Home

hand terminal-mf hand terminal-mf

image

Contents

1. HAND TERMINAL MF im HAND TERMINAL MF USER GUIDE Ja GID SG fa U 0 kud DDDD Blog p i 0 0 Contents Parameter Description User Manual PC Link Clock Card Install Card Open Record Set Password Set Datetime Stop Lock Check Out Card Power Off Trouble Shooting Warning ME a e RFID module High frequency mode 13 56MHz Input method Keypads 27 keys Clock format YYYY MM DD HH mm ss Safety module PSAM interface for data encryption and backup Rechargeable Li ion battery 3400mAh DC4 2V Dimension 185mm 70mm 35mm Net weight 350g MONTI MON Tu UNI Temperature 5 C 50 C Humidity 30 85 RH Protection IP54 Shock resistance 150cm to concrete surface 01 02 LED Indicator LCD screen Confirm button Cancel button Control buttons Power button USB ports NOOR WON A GO r GOGQ DDOD Dlaaad ja U u aooo view 8 RF induction zone 9 Li on battery slot MINI USB Connector USB Connector MINI USB connector is connected to hand terminal side USB Connector is connected to computer side Notice Data line is used for battery charging and data transmission 03 Hand terminal is powered on b
2. press initialize Hand terminal and Export Room info button to load hotel info into the terminal 06 Clock Card Please select clock card from main menu or press 2 The following screen will appear Please press OK hand terminal will give a Bi sound means it s turned to clock card mode Read Authorized Card firstly to the lock and then the hand terminal can correct the time of lock ay SET clock card YYYY MM DD 9 32 16 OK to set C to return ay SET clock card Set Time OK YYYY MM DD 9 32 16 OK to set C to return 07 Install Card Please select install card from main menu or press 3 The following screen will appear Room amp Time means to set room information and correct time to the lock at one time So is Public room amp Time Please enter the required information Please input the name of the room number or ID number then press OK to search room information 08 Set LV3 ROOM ROOM ROOM amp TIME PUBLIC ROOM PUBLIC ROOM amp TIME Press AV to choose Press ok to enter 9 32 ET ROOM CARD NAME ID Amount Press AV to choose Press ok to check Press C to return If enter message is correct all information of the room will be appeared on the screen Please press OK The following screen will appear While on this menu please read hand terminal t
3. al and the screen showing Read part 1 OK which means Data Part 1 has been transferred to hand terminal successfully Read the hand terminal to the lock again continue the same operation to retrieve the Data Part 2 and Part 3 Record location 001 Wait For read Press ok to read Press C to return Record location 001 Wait For read Read Part 1 ok Press ok to read Press C to return Record retrieve completes when this screen appears Read 200 records and lock info is the same steps as read 1000 records Select Check record to check brief data from the lock It returns to main menu by pressing C button To transfer all data into PC select PC Link on terminal Hardware version H 10 11 Software version S 00 03 12 Record location 001 Read Part 1 ok Read Part 2 ok 1000 Records Read Completely Press ok to read Press C to return Record location 001 1000 Records Area 1 Building 1 Floor 1 Room 1 H 10 11 S 00 03 YYYY MM DD 9 32 16 Set Password Please select set password from main menu or press 5 The following screen will appear The old password can be seen on the screen Input a new 6 digit number can change the password Set Date amp Time Please select set date amp time from main menu or press 6 The following screen will appear User can update the time without co
4. ibly battery runs out Connect terminal unit into PC by USB port 2 User password is not accepted or forgotten Make reconfiguration of terminal unit by connecting into PC by USB port Warning 16 Do not put too much pressure on the LCD screen or subject it to strong impact otherwise it will break Press the buttons with fingers or blunt objects only Pointed object will damage the surface of the keypad and cause a short circuit inside the terminal Do not take out the battery when the power is on which may cause data loss in the memory Do not place the terminal facedown which may cause abnormal operation of the keypad Use a soft and dry lens cloth to clean the terminal
5. nnecting to the computer Set Password Password 123456 New Password Enter 6 digit PW OK Cancel SET DATE amp TIME YYYY MM DD 09 32 00 Press AV lt gt adjust OK Cancel 13 Stop Lock Select Stop lock option from main menu or press 7 This function is used to stop lock s unlocking function temporarily in case of accident Read Authorized card to the lock and then the hand terminal all cards will be out of use except the Emergency card and Master card Repeat the above operations can cancel the stop function Check Out Card Select Check out Card option from main menu or press 8 This function is used for check out Read authorized card or others access cards to the lock and then the hand terminal guest cards will be out of use 14 9 32 ay Stop Lock Press ok to set Press C to return 9 32 mm Check Out Card Only apply to LV4 Press ok to set Press C to return Power Off Press power button or select power off on main menu to turn off the hand terminal Additional Function Fess occ Long press F8 Power button 1 Update app additional function page will be 5 Green shown 3 Run user app User can use additional function 4 System info according to their required 5 Keypad test 6 Language 7 Special Fun 8 Power off 15 Trouble Shooting 1 No power on terminal unit Poss
6. o the lock to complete programming procedure ROOM INFO ID 0001 Name 01101 Area 001 Building 001 Floor 001 Room 001 Suite 000 Press AV to choose Press ok to set Press C to return Set Room OK Info data OK 09 Record Please select record from main menu or press 4 The following screen will appear Select Download record 4 different record modes will be shown Read 1000 by card only for Hotel lock Read 200 by card for Hotel lock and Office lock Read Lock Info for Hotel lock Read by IR This function is not activated 10 Record Menu Download record Check record Press AV to choose Press ok to enter Record Mode Read 1000 by Card Read 200 by Card Read by IR Read Lock Info Press AV to choose Press ok to enter Select Read 1000 by card and choose the record station the following screen will appear While on this screen read data card to the lock first when blue light gets on read the hand terminal immediately to the lock When hearing a Bi sounds from terminal and the red and blue light flicker alternately from the lock data is transferring from lock to terminal Wait till a Bi sounded and the blue light stays on press OK to save Data Part 1 When the red light of hand terminal flickers it s saving data to the terminal memory Wait till hearing a another Bi sound from hand termin
7. y pressing the power button for 3 seconds The following screen will appear Press OK button again hand terminal will ask for entering password Default password 123456 If device password is lost user must connect it to software and change password 04 932 CW Welcome MF1 Hand Terminal YYYY MM DD Version x x Password Enter Password Enter the password and press OK button If the password is incorrect warning screen asks for a password again If the password is correct the following main menu appears In this menu user access to all functions OMNANAWNHE 9 32 Hand Terminal PC LINK Clock Card Install Card Open Record Set Password Set Datetime Stop Lock Check Out Card Power Off 05 PC LINK Hotel configuration and some other basic info must be loaded to the hand terminal before first time running Select PC LINK from main menu or press 1 the following menu appears While terminal is on this function all data can be transmitted between lock software and the hand terminal 1 Hotel configuration and some basic info are loaded into terminal 2 Terminal info is loaded into the software PC LINK C to return Connect the hand terminal to the computer with data line And then enter lock software Card Management Special card Hand terminal interface and

Download Pdf Manuals

image

Related Search

Related Contents

"取扱説明書"  Mode d`emploi pour le choix des Options  Page 1 Page 2 かい 作動スイッチ ※この変身遊びは 「タトバコンボ」 を例  PDF: 201 KB - Department of Infrastructure and Regional    HunterEye TC5401NA - MERK Sicherheitstechnik    User Manual - ADFWeb.com    71919 - BA S300 DFE.indd  

Copyright © All rights reserved.