Contents
1. GARDINER TECHNOLOGY GARDTEG 200 SERIES GARDTEC 350 Installation Instructions GARDTEC 350 Contents Introduction Keypad Description amp changing orientation LED Functions Programming Modes Engineer Programming Programming General Routine Programming Bell Option Programming Entry Option Programming Exit Option Programming Sounder Option Programming Zone Option Engineer User Programming Overview Removing Zones Testing the System Reading the Log Setting Chime On Off Programming Engineer Code Full Setting the System Part Setting the System Unsetting the System Resetting After an Alarm Factory Defaults amp Options Control Panel Fixing P C B Layout Output Connections Input Connections Mains Connections Detector Wiring Tamper Wiring Speaker Wiring Self Actuating Sounder Wiring Conventional Bell Box Wiring Fault Finder Zone Terminology User Code Types Gardtec 350 Specification System Record GARDTEC 350 Patent Pending Engineers Manual N O O O OQ 10 13 10 10 11 11 11 12 12 13 13 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 27 28 29 GARDTEC 350 Engineers Manual INTRODUCTION The Gardtec 350 is a five zone microprocessor based Control panel Each of these zones is fully programmable The unit may be mounted either vertically or horizontally to enhance it s flexibility Three part set suites are available zones progra
2. GARDTEC 350 Engineers Manual PRINTED CIRCUIT BOARD LAYOUT 2122212222 222 L 00 a Q B AUX 12V s CAUTION OBSERVE ANTI STATIC gt TECHNOLOG PROCEDURE Gardtec 350 only gt ENGLAND1 01706510000 SPKR ADJ BoA Gardtec 350 only E E F2 200 mA Q B GARD12V A lt z a D2 O lt lt a GARD OV GARD 12V It should be noted that the following items are only available on the Gardtec 350 RV1 Used to obtain further adjustment to the volume of the low volume tones from the speaker TB3 Used for the connection of expansion devices eg Remote Keypads Fuse protection for TB3 Page 16 GARDTEC 350 Engineers Manual OUTPUT CONNECTIONS Output for latching detectors locks etc Strobe Self contained Sounder eg Novagard NOTE The Gardtec 350 has 0 8 Amp available to supply detectors Sounders Strobes etc When planning your system you MUST make sure that this is not exceeded Damage caused through overloading the Gardtec 350 may not be covered by the war ranty The PGM terminal is open collector output held high trough an integral 1k pull up resis tor The maximum sink capability of this terminal is 50mA N B The 350 has an additional supply capability of 0 2A through TB3 Page 17 GARDTEC 350 Engineers Manual INPUT CONNECTIONS Normally Devices Normally Closed Devices AZ1 Normally N Devices Normally Closed Devices AZ2 Normally Device
3. User Mode Page 10 GARDTEC 350 Engineers Manual READING THE LOG With the panel in Engineer User Programming Mode Press NO until the LOG LED is flashing Press YES The last event will be displayed Press NO to read the previous event move back Press YES to read the next event move forward To escape out of Log Mode Press 0 Then Press NO to move to the next option or Press 0 if you wish to escape out of Engineer User Mode SETTING CHIME ON OFF With the panel in Engineer User Programming Mode Press NO until the CHIME LED is flashing Press YES if you wish to reverse the chime status The CHIME LED will illumi nate steadily and the enter LED will flash Pressing YES again will escape the Chime mode Note Chime zones should also be programmed from Engineer Mode Then Press NO to move to the next option or Press 0 if you wish to escape out of Engineer User Mode PROGRAMMING ENGINEER CODE With the panel in Engineer User Programming Mode Press NO until the PROGRAM LED is flashing Press YES The PROGRAM LED will illuminate steadily The ENTER LED will flash Enter a new four digit Engineer code Press YES The PROGRAM LED will stay illuminated and the ENTER LED will flash asking you to confirm the new code Re enter the new four digit Engineer code Press YES A comfort tone will be generated if codes match If NO is pressed at any stage during the above or if the procedure is not followed cor Page 11 GARDTEC
4. by removing the wiring at the sounder and connecting the Nicad battery Disconnect the Nicad battery from the SAB of the sounder Check to see if the hold off voltage from the Control Panel is present at the SAB if not check replace Control Panel fuse If fuse is O K check hold off voltage at Control Panel with wiring removed If hold off voltage O K check replace wiring SAB Page 25 GARDTEC 350 FAULT Tamper is not tripped when detector cover is removed Detectors false alarm Control Panel shows Lid Tamper when cover is in place Control Panel parameters are unchanged after programming User and or Engineer code have been forgotten Engineers Manual ACTION Check that the tampers are in series If all is O K check for short circuits Remember short circuits are easily caused through staples piercing cables Check that the position of the detector is in accordance with the manufacturers recommendations In the case of a P I R ensure that the unit is not facing a window or situated in a draughty location In the case of a shock sensor ensure that it is not bridging any joints In the case of a contact check the gap and that there is no excessive movement of the protected item Check also that low voltage alarm cables do not run parallel to mains cables Where they do so they should be at least 9 inch es apart when crossing they should do so at 90P Check the tamper spring is attached to the t
5. used When engineer programming mode is being used please use the keypad overlay shown below POWER 11 DAY Use this display z layout when in Z2 engineer pro z3 gramming mode Z4 Z5 TAMPER Page 1 GARDTEC 350 Engineers Manual Throughout this manual reference to the display will be accompanied by a diagram showing the status of the LEDs Three modes are possible from each LED and will be shown as follow C1 OFF mm ON au FLASHING PROGRAMMING MODES Two programming modes are available to the engineer Engineer programming and Engineer User programming To enter Engineer Programming Mode with the panel unset enter engineer code and press YES The following options may then be programmed BELL OPTION BELL TIME and number of RE ARMS ENTRY OPTION ENTRY TIME 1 and ENTRY TIME 2 EXIT OPTION FULL SET EXIT TIME and PART SET EXIT TIME SOUNDER OPTION ENTRY EXIT LEVEL CHIME LEVEL SILENT PART SET and PROGRAMMABLE OUTPUT MODE ZONE OPTION ZONE NUMBER ZONE TYPE PART SET STATUS and CHIME STATUS To enter Engineer User Programming Mode with the panel unset enter the engineer code and press YES The following options may then be programmed REMOVE OPTION Allows individual Zones to be Removed TEST OPTION Allows the System to be Tested LOG OPTION Allows the Log to be Read CHIME OPTION Allows the Chime option to be turned On and Off globally PROGRAM ENGINEE
6. 0200 Mon Fri 09 00 1700 DI Ore q c re Vi N y ko INNOVATION TECHNOLOGY QUALITY PR2ao6 REV Q
7. 350 Engineers Manual rectly then the code will not be updated and no comfort tone will be generated Pressing NO will now move to the next option or Press 0 if you wish to escape out of Engineer User Programming Mode TO FULL SET THE SYSTEM USING ENGINEER CODE The System may be set using the Engineer Code It should however be noted that the System may only be Unset using the Engineer code if it has been Set with the Engineer code With the Control Panel Unset POWER amp DAY LEDs On proceed as follows Enter the Engineer code the day LED will flash then exit tone will sound if you wish to abort setting the system re enter code Leave the building via the authorised exit route any zones activated during Exit will cause a change in tone to the Exit tone The activated zone will also be displayed via the relevant LED After the programmed Exit time the Panel will Set TO PART SET THE SYSTEM USING ENGINEER CODE To Partset the system using the Engineer code proceed as follows Enter the Engineer code The day LED will flash then exit tone will sound if you wish to abort setting the system re enter code Press 1 if Partset 1 is required Zones programmed into Part 1 will be removed or Press 2 if Partset 2 is required Zones programmed into Part 2 will be removed or Press 3 if Partset 3 is required Zones programmed into both Part 1 and Part 2 will be removed It should be noted if part set 1 2 or 3 has been selecte
8. R CODE OPTION Change Engineer Code The same options in Engineer User Programming Mode are available in the User programming Mode with the amendment that USER CODES are programmed Page 2 GARDTEC 350 Engineers Manual The options available from the two engineer modes are illustrated below Press NO Use REMOVE option Page 10 Press NO Use TEST option Page 10 Press NO Use LOG option Page 11 Press NO Use CHIME option Page 11 Press NO Use PROGRAM option Program ENGINEER CODE Page 11 Enter engineer code Press System starts to set YES Select Part set options or Program BELL options Page 5 Press System sets NO Program ENTRY TIME options Page 6 Press NO Program EXIT TIME options Page 7 Press NO Program SOUNDER options Page 8 Press NO Program ZONE options Page 9 Page 3 GARDTEC 350 Engineers Manual ENGINEER PROGRAMMING Engineer programming general routine The general programming routine is as follows Enter the Engineer Code 1234 factory default Panel will start to set Press YES Before entry time expires the POWER AND Z1 LEDs will now flash This is Engineer mode From this point on the display layout on page 1 or the engineer pro gramming card is used Press NO until the LED for the option you wish to program is flashing Press YES the LED for that option will now illuminate steadily and the Enter LED will
9. amper switch on the PCB module Check that LK1 is in place on the PCB Access may be gained to the system by removing LK1 and using factory default codes replace LK1 after access has been gained The system may be reverted to factory defaults as shown on pages 13 amp 14 Page 26 GARDTEC 350 Engineers Manual ZONE TYPE TERMINOLOGY The terminology used for the various zone types are explained in this section 12 Hour Zone active when Control Panel is Set Access Will allow to pass through on Exit Will allow to pass through on entry only if entry exit is opened first 24 Hour Internal sounder if Unset Full alarm if Set Entry Exit Zone used as last exit point Will start entry time when opened if panel is Set Part E E As Access if Control Panel is Full Set As entry exit if Control Panel is Part Set P A 24 Hour Personal Attack Active if Control Panel is Set or Unset Alert Internal sounder only Recorded to Log Fire Will give Fire alarm when activated pulsed sounders with panel set or unset USER CODES amp TYPES User 350 Code Type 350 Code Type User 1 Master Master User 2 User User User 3 Set Only Set Only User 4 N A Master User 5 N A Master User 6 N A User User 7 N A User User 8 N A User User 9 N A Set Only For further details about user codes please refer to the user manual Page 27 GARDTEC 350 GARDTEC 350 SPECIFICATION Power Input Max Loop Resistance Loop Delay Time Fuses Main
10. conds 9 Part set Exit Time 0 99 seconds 2 Bell On Time 0 99 minutes Programmable 0 Pulse On 1 Sw when set 2 Pulse Off Output 3 On with Bell 4 On with Strobe 5 On in E E 6 On in Test 7 On with Internal Alarm Engineer Code Any Four Digits 1234 Any Four Digits 5678 Page 14 01 02 5 5 3 30 30 30 20 99 2 GARDTEC 350 Engineers Manual 350 CONTROL PANEL FIXING The Gardtec 350 Control Panel may be fixed in a horizontal or vertical position The software will allow the orientation of the keypad to be changed a vertical keypad sticker is available as an optional extra The Control panel should be fixed to the wall using one hanger position and two fixing points The backplate should be used as a template for marking the wall Under no circumstances should you drill through the back plate Screw size should be No 8 x 30mm minimum Details of the Gardtec 350 back plate can be seen in the diagram below K K D G fa Ola ty CP CO _ B hme See eae 7 1 2Ah battery terminals c B F EE ocsi i i i Aa 1 1 D4 K K A Transformer F Battery Retaining Clips B Mains Connector Block G Vertical Fixing Points C Speaker Position H Horizontal Fixing Points D Cable Entries J Spare Fuse Holder E Rear Tamper Switch Position K Trunking Entries Page 15
11. d the day LED will flash at a slower rate Also if the silent part set option has been programmed the exit tone will be silenced Leave the premises or retire to an authorised area After the programmed exit time the System will Set If the silent Partset has been chosen the Setting will be confirmed with a single beep at the end of the Exit time If detectors are still in fault at the end of the exit time a fault tone will be generated If a fault is present the control panel will not set Page 12 GARDTEC 350 Engineers Manual TO UNSET THE SYSTEM USING ENGINEER CODE It should be noted that the System may only be Unset using the Engineer code if it has previously been Set using the Engineer code To Unset the System proceed as fol lows Enter the premises via the authorised Entry point The Entry tone will sound Entry Time1 Ifthe panel is not unset during Entry Time 1 the tone will increase in volume and pace this is Entry Time 2 Proceed directly to the Control Panel and Enter the Engineer code the day LED will illuminate The system is now Unset Ifthe panel was not unset before Entry Time 2 expired a full alarm condition will occur Ifthe alarm was activated whilst the system was set all the LEDs will flash when the system is unset Press NO to view the cause of the alarm The system will now need to be reset as shown below RESETTING AFTER AN ALARM If the system is set unset it as shown above and proceed as follo
12. engineer code 1234 factory default The Control Panel will start to set Press NO before the exit time expires the POWER and DAY LEDs will extinguish and the REMOVE LED will flash This is Engineer User Programming Mode The function of the LEDs should now be read from the White legend on the affixed keypad sticker To go direct to a particular function Press NO until the required LED is flashing If at any time during Exit time the code is re entered the Panel will return to DAY Unset Mode REMOVING ZONES With the panel in Engineer User Programming Mode Press NO until the REMOVE LED is flashing Press YES The REMOVE LED will illuminate steadily NOTE This function is in addition to Part Sets Enter the required zone number followed by YES to Remove or NO to Un Remove A comfort tone will be generated You must repeat this for each zone you wish to REMOVE If you wish to escape from the Engineer User Programming mode and set the panel with the Zone s removed Press 0 TESTING THE SYSTEM With the panel in Engineer User Programming Mode Press NO until the TEST LED is flashing Press YES The TEST LED will illuminate steadily Any Zone activated will now produce a tone and the appropriate zone LED will illuminate Pressing 9 whilst in this mode will toggle the external sounder strobe On and Off To escape out of Test Mode Press 0 Then Press NO to move to the next option or Press 0 if you wish to escape out of Engineer
13. er your four digits followed by YES A tone will be heard if option is updated To move to another option use the NO key If you wish to escape out of engineer mode and return to Unset PRESS 0 Page 7 GARDTEC 350 Engineers Manual SYSTEM PROGRAMMING SOUNDER OPTION With the Control Panel in engineer mode PRESS NO until the POWER amp SOUNDER LEDs are FLASHING PRESS YES display will show POWER 1K DAY Z1 Z2 Z3 Z4 mmn z5 TAMPER Miq The Enter LED is now flashing asking you to enter a four digit number Choose from 1st Digit 2nd Digit 3rd Digit 4th Digit Chime Volume Entry Exit Volume Setting Sounders Programmable Terminal O All Parts silent 0 Pulse On 1 Part 2 silent 1 Sw when set 2 Parts 1 amp 3 silent 2 Pulse Off 3 All parts audible 3 On with Bell 4 On with Strobe 5 Onin En Ex 6 On in Test 7 Onin Int Alarm Note The Chime and E E volume adjustment is extended through the use of the onboard potentiometer on the Gardtec 350 As an example 5501 would give a volume level of 5 for both Entry Exit and Chime vol ume all part sets silent and the programmable terminal will pulse Off during the setting period Enter your four digits followed by YES A tone will be heard if option is updated To move to another option use the NO key If you wish to escape out of engineer mode and return to Unset PRESS 0 Page 8 GARDTEC 350 Engineers Manua
14. flash Enter an appropriate four digit number Press YES An audible tone will be heard if option is updated Use the NO key to move onto other option s or the 0 key to quit Engineer Programming mode A more detailed method for each option now follows SYSTEM PROGRAMMING With the control panel unset Enter the Engineer Code 1234 factory default Panel will start to set Press YES before entry time expires Exit sounder will silence The display layout shown on page 1 or the engineer programming card is used whilst in this mode The POWER LED will be flashing This shows you are in engineer mode The BELL LED will also be flashing This is asking do you want to program this func tion If at any time during the Exit time the code is re entered the panel will return to DAY Unset mode Page 4 GARDTEC 350 Engineers Manual SYSTEM PROGRAMMING BELL OPTION With the Control Panel in engineer mode PRESS NO until the POWER amp BELL LEDs are FLASHING PRESS YES display will show POWER MK DAY Zi EE Z2 Z3 L Z4 Z5 TAMPER Mkt The Enter LED is now flashing asking you to enter a four digit number Choose from 1st amp 2nd Digits 3rd amp 4th Digits Bell On Time Number of Re Arms Minutes As an example 2003 would be Bells on for 20 Minutes with 3 Re Arms Enter your four digits followed by YES A tone will be heard if option is updated To move onto anothe
15. he Control panel may be completed and adhered to the inside of the front cover next to the main PCB Page 24 GARDTEC 350 FAULT FINDER FAULT Control Panel will not power up from mains supply Display shows a zone fault and Panel will not set after exit time has expired Control Panel gives a tamper fault Tripping a detector does not cause an alarm and is not registered at the Control Panel External sounder does not sound External sounder rings without the Control Panel triggering it Engineers Manual ACTION Check Replace fuse in fused spur mains connection block Also check for trapped wiring insulation Remove zone wires from the problem zone at Control Panel and replace with a link Check if panel now sets If all is O K check with a multimeter continuity of the wires you have removed Also check that there is no short circuit between the zone and tamper loop or the zone and OV Link out the tamper loop that is displaying the fault and recheck If all is O K test con tinuity of the faulty loop Also check for short circuits to other cores of the cable Check for short circuits on the problem zone If two detectors are fitted to the same zone try tripping them both at the same time to determine whether they are wired in series Use a multimeter or small buzzer across the Bell amp terminals to determine if the Control Panel is firing the Bell If all is O K check the operation of the sounder
16. l SYSTEM PROGRAMMING ZONE OPTION NOTE You will need to repeat this procedure for each zone you wish to change With the Control Panel in engineer mode PRESS NO until the POWER amp ZONE LEDs are FLASHING PRESS YES display will show POWER Hi DAY Zi Z2 Z3 z4 Z5 mm TAMPER Mq The Enter LED is now flashing asking you to enter a four digit number Choose from 1st Digit 2nd Digit 3rd Digit 4th Digit Not Used Zone Number Zone Type Zone Control Always 0 0 12 Hour 0 Full Set 1 Entry Exit 1 Part1 Removed 2 Access 2 Part2 Removed 3 Panic 3 Part1 amp 2 Rem 4 24 Hour 4 Full Set Chime 5 Fire 5 Part1 Chime 6 Alert 6 Part2 Chime 8 Part Entry Exit 7 Part1 amp 2 Chime The terminology used for zone types is given on page 27 As an example 0315 would make zone 3 an Entry Exit zone that is removed when the system is part 1 set and is on Chime when the system is unset Enter your four digits followed by YES A tone will be heard if option is updated To move onto another option use the NO key If you wish to escape out of engineer mode and return to Unset PRESS 0 Page 9 GARDTEC 350 Engineers Manual ENGINEER USER PROGRAMMING OVERVIEW This mode allows options shown in White on the Control panel label to be pro grammed To enter the Engineer User Programming Mode proceed as follows With the Control Panel Unset POWER amp DAY LED illuminated enter the
17. mmed as part set zones will be removed when the appropriate part set is selected The power supply rating of the Gardtec 350 is 0 8 Amp enough to cope with the average domestic or small commer cial installations The compact size coupled with the range and variety of functions make it an ideal choice for the domestic small commercial bells only system Factory codes are 1234 for engineer and 5678 for user KEYPAD DESCRIPTION The keypad takes the form of a 4 x 3 0 9 YES NO matrix The orientation of the key numbers will depend on the Gardtec 350 being mounted vertically or horizontally The unit is supplied with the horizontal label fitted and the vertical label is available sepa rately If you wish to change the orientation of the panel fit the vertical keypad overlay A delay will occur when the panel is powered up Press 00 for the key pad you have chosen during this power up delay The orientation of the keys is now correct for your chosen keypad Pressing 4 6 YES NO during the power up delay will revert the unit back to fac tory defaults NOTE this will not affect the keypad orientation LED FUNCTIONS The display is via eight LEDs There are three modes of LED operation two user and one engineer mode The two user modes for the LEDs are shown on the keypad over lays During primary setting unsetting etc operation the functions shown in Black are used During secondary user programming mode the functions shown in White are
18. n example of this is given below using connector block strip lt Detector 5 Tamper Detector 1 Tamper lt Page 21 GARDTEC 350 Engineers Manual SPEAKER WIRING One speaker is fitted to the Gardtec 350 as standard One extra 16 speaker may be fitted if required this speaker should be wired in series with the existing speaker as shown below Speaker 1 Speaker 2 SPEAKER Page 22 GARDTEC 350 Engineers Manual SELF ACTUATING SOUNDER WIRING Below is shown a typical wiring example of the Novagard 1E Self Actuating Sounder and the Novagard 2 range of Self Actuating Sounders It should be noted in both cases that when the Nicad battery is connected the sounder will sound until the power from the Control panel is applied and the sounder cover is in place Novagard 1E Gardtec 350 STROBE SUPPL BELI TMP TMP The order shown for Novagard 2 Range the sounder terminals may change depen dent on model used Gardtec 350 Page 23 GARDTEC 350 Engineers Manual CONVENTIONAL BELL BOX WIRING Conventional type Bell Boxes should be wired as shown below Care should be taken not to exceed the current rating of the Control panel when more than one sounder is used STROBE LIGHT SOUNDE r r BELL BO TAMPER Once the system has been commissioned and the final checks have been carried out the zone label supplied with t
19. r option use the NO key If you wish to escape out of engineer mode and return to Unset PRESS 0 Page 5 GARDTEC 350 Engineers Manual SYSTEM PROGRAMMING ENTRY TIME OPTION With the Control Panel in engineer mode PRESS NO until the POWER amp ENTRY LEDs are FLASHING PRESS YES the display will show POWER Mk4 DAY Zi Z2 ma Z3 Z4 Z5 TAMPER aE The Enter LED is now flashing asking you to enter a four digit number Choose from 1st amp 2nd Digits 3rd amp 4th Digits Entry Time 1 Entry Time 2 Seconds Seconds As an example 2010 would be 20 seconds Entry Time 1 and 10 seconds Entry Time 2 Enter your four digits followed by YES A tone will be heard if option is updated To move onto another option use the NO key If you wish to escape out of engineer mode and return to Unset PRESS 0 Page 6 GARDTEC 350 Engineers Manual SYSTEM PROGRAMMING EXIT TIME OPTION With the Control Panel in engineer mode PRESS NO until the POWER amp EXIT LEDs are FLASHING Press YES display will show POWER M DAY Zi Z2 Z3 mm Z4 Z5 TAMPER Miq The Enter LED is now flashing asking you to enter a four digit number Choose from ist amp 2nd Digits 3rd amp 4th Digits Full Set Exit Time Part Set Exit Time Seconds Seconds As an example 2010 would be 20 seconds Full Set Exit Time amp 10 seconds Part Set Exit Time Ent
20. s Aux Gard 350 only Low Voltage Output Quiescent Current Current Rating Battery Sizes Construction Mounting Positions Complies with Number of Zones Display Type User Code Default Engineer Code Default Event Log Size Number of User Codes Engineers Manual 240V a c 10 50Hz 2K 300 milliseconds 200mA Quick Blow 800mA Quick Blow 200mA Quick Blow 13 8V typical Regulated 50mA 800mA 12V 1 2A 12V 2 0A 3mm Polycarbonate Horizontal or Vertical B S 4737 Part 1 5 Tamper LED 5678 1234 50 3 ADDITIONAL GARDTEC 350 FEATURES Nine user codes Keypad backlight Onboard potentiometer for further adjustment of low volume tones Log size increased to 80 events Data ports for connection of expansion devices eg Remote Keypads Additional fuse protection Page 28 Engineers Manual GARDTEC 350 Q0UGJOJO 1nlni 104 2 d jes e u p Jols pue uongiie sul Jo uun u1 ye 9 u Bu y Aq p 1 lduuo2 q pinous pio5 91 SIU L JeuIWa lqeuuuieiBoid sjapunos Bun s auNnjoA 3 3 unIoA aWYyD aul 4X4 19S Hed aul 4X4 19S IINA z w Aug L aunty Agua suuy 4 18g JO 49quunN u1 UO 119g sajeq ang ad1Aas 1eq uonelle1su Joy iSutolsnO ON L i9uuolsno GHOO938 WALSAS OS DJ4L0HVS Page 29 GARDINER TECHNOLOGY Gardiner Technology Ltd Queensway Rochdale Lancashire OL11 1TQ United Kingdom Tel 01706 510000 Fax 01706 310000 Technical Support 01706 51
21. s Normally Closed Devices AZ3 Normally Devices Normally Closed Devices x AZ4 Normally Devices Normally Closed Devices x AZ5 Normally Closed Tamper Loop x TAMP Page 18 GARDTEC 350 Engineers Manual MAINS CONNECTION It should be noted that in order to comply with the requirements of B S 4737 an unswitched fused spur should be fitted outside the Control panel Details of this con nection can be seen below Consumer Unit r Unswitched F m _ ae Q Earth j Neutral Mains Connection Block Control Panel Cable Colours RED LIVE GREEN YELLOW EARTH BLACK NEUTRAL Page 19 GARDTEC 350 Engineers Manual DETECTOR WIRING Below is a typical example of wiring a Gardscan 212 PIR to the Gardtec 350 Control panel The wiring of a Shockgard vibration detector would be the same with the W T terminal omitted Single Detector Per Zone 2 2 2 2 72 2 212 gt N e Slll TAMP AUX F N lt Page 20 GARDTEC 350 Engineers Manual TAMPER WIRING The Gardtec 350 has two tamper loops available the first being the Bell tamper situat ed near the output terminals labelled BELL HOLD and SAB TAMP The second is the Zone tamper and is situated at the end of the zone terminals All zone tampers should be in series format This may be easier if the splitting of the tampers is in the Control panel A
22. ws After an alarm all the LEDs will be flashing press NO if you wish to view the cause of alarm Enter the engineer or master user code the system will start to set Before the entry time expires re enter the code to abort the setting The system is now reset FACTORY DEFAULTS If the engineer or master user codes have been forgotten temporary access may be gained by removing LK1 from the main P C B The factory set codes 1234 engineer or 5678 master may then be used to gain access to the desired function It should be noted that LK1 MUST be replaced before any option can be re programmed Page 13 GARDTEC 350 Engineers Manual FACTORY DEFAULTS cont To revert to Factory Defaults 1 Power the panel up and press 00 within 5 seconds 2 Remove all power from the Control Panel Leave power off for at least 10 seconds 3 Re apply the power to the Control Panel and Press 4 6 YES NO within 5 seconds FUNCTION OPTIONS AVAILABLE ao 3rd DIGIT ZONE TYPE 4th DIGIT ATTRIBUTES Zone 1 0 12Hr 1 Entry Exit 2 Access 0 Full set 1 Pt1 Rem 2 Pt2 Rem 3 Panic 4 24Hr 5 Fire 3 Pt1 amp 2 Rem 4 Full set chime 6 Alert 8 Part Entry Exit 5 Pt1 chime 6 Pt2 chime Terminology for zone types shown on page 27 7 Pt1 amp 2 chime eee Chime Level Entry Exit Level Part set Sounders O All parts silent 1 Part2 silent 2 Parts1 amp 3 silent 3 All Parts Audible Entry Time1 0 99 seconds Entry Time 2 0 99 seconds 10 Full set Exit Time 0 99 se
Download Pdf Manuals
Related Search
Related Contents
Samsung NT200B5C User Manual (Windows 7) Design House 510297 Installation Guide GUIA DE REF.SERVIDOR ITAUTEC MX 203.indd 特 長 工場エネルギー管理システム 「SAN FEMS R ライト」 John Deere Frontier Equipment Septic System 294012 User's Manual Brodit Passive Holder,Tilt Swivel (PN-ZT10)取扱説明書 CORINA Copyright © All rights reserved.