Home
ScanVue User Manual
Contents
1. 27 Mounting the ScanVue 8000 Web Client Kiosk ccrte 29 Standard Wall Mount Installation th err Ra Rep nens ea Ea ena ona ean seen Eus 29 Chapter 4 ScanVue Web Client 30 Side el 30 NNI TTE T 32 ScanVue Web Client Kiosk Supported Modes ccsscssssesssesecececeseseseseseseseseseseeveveveveveveverevavans 33 Wireless Network Setup cccccccsseccccsseeeceesseccceasececsaseeceeaseeeesaueeecsaseeseeageeessageeessagsessesaseeeess 37 AEF BUN held TRE 37 WPA WPAZ Encryption Settings cicocecc2nnahcas lt dheinccanntsnazedidennnteddiancadbnandsamensnneatictenenmeueecesxtt be 37 14 May 2015 Rev B 4 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 5 Interactive Device Options cccccecccssesseeceeeeeeeaeeeeseeceeeeessaeeeseeeeeeeesssaaaeeeeeeeees 38 ocal ene ote dI ell LRL IR 38 Barcode Scanner SOLIS uet DR 42 Configuring Seal VEG 42 Ns le cag 44 TABLE OF FIGURES Figure 1 Configuration Info Screens 1 and 2 12 Figure 2 Connector Location Rear of 27 Figure 3 Ethernet PoE Connector RJ45 Pin Assig
2. 14 May 2015 Rev B 20 Computer Name Hardware Advanced System Protection Remote uses the following irfomnation to identfy your computer Computer descnpgeon For example Tachen Computer or Mary s Computer Rd computer name ScanVue Interactive Web Client Kiosk 4 Enable User Guest Account User Manual M8000 02 e Enter Control Panel gt All Control Panel Items User Accounts to display administrator account B Control Panel All Control Panel items User Accounts Fie View Central Patel Hense Manage your credentials Creabe a passwore reset dick Link online Ds Manage your file encryption certilicates Configure advanced profile propertees Chart my emanenment WP Parental Controls e Click on Manage another account to show Guest account Make changes to your user account Change pour password Ferrero your john Adminstrator Change your pechare protected Change your account name Change your account type a Manage another account My Change User Account Control settings Choose the account you would like to change dj Guest ij Guest account is off Create new account What uper accent Additional things you can do Set up Parental Comtrols Goto the main User Accounts page e Ifthe Guest icon says Guest account is off click the Guest icon to display the following window 14
3. 16 ocanVue Documentation Access Instructions 16 SDK Files and Software Installation eese mmn nenne 16 17 Part 2 Local PC Host Server Network 18 PVF PM O ese eect ec eect ces T E 18 Network Setup Example Procedure Windows 7 19 Part 3 Demo Mode 24 BESES a ee ET 24 PN TAS I mERTRT 24 Part 4 Home Web Page Interactive Mode 25 Ba 1 T 25 Sample Script Image File Installatlloli inea Io Enna oontra t eph nt Rura 25 Tesi Procedure UT I 25 Chapter grinch snr iii 27 Connections For PoE Power Communication 27 Connections For 12V Power Ethernet Communication esee 27 Connections For 12V Power Wi Fi 802 11b g Communication
4. All information in this manual was deemed correct at the time of printing Updated versions of this manual will be published periodically and may be downloaded in Abode Acrobat PDF format from IEE s website WWW IEEINC COM Copyright O 2015 IEE Inc All Rights Reserved 14 May 2015 Rev B 2 ScanVue Interactive Web Client Kiosk User Manual M8000 02 STANDARDS CERTIFICATION The ScanVue product described in this manual has been fully tested and certified by an independent testing laboratory and is compliant with the following international standards e UL Standard 60950 ITE listed product e CSA standard C22 2 No 950 recognized product e RF Emmissions Conducted FCC CFR Title 47 part 15 Subpart B Class A e RF Emmissions Radiated CISPR 22 called out in FCC CFR Title 47 part 15 Subpart B Class A e EN55022 2010 AC 2011 Class A e EN55024 2010 e EN61000 3 2 2006 A1 2009 amp A2 2009 e EN61000 3 3 2008 The internal Wireless LAN PCle Minicard is certified by the manufacturer to be compliant with the following standards e EN60950 1 2006 A11 2009 EN 50385 2002 EN 301 489 17 e EC 60950 1 2001 FCC 15B 8 part 15C CAUTIONS Caution Do Nor DISPLAY FIXED IMAGE FOR EXTENDED PERIODS OF TIME AS THIS MAY CAUSE LCD IMAGE PERSISTENCE PRODUCING PIXEL DISCOLORATION 14 May 2015 Rev B 3 ScanVue Interactive Web Client Kiosk User Manual M8000 02 TABLE OF CONTENTS TARLE OFF URE
5. Security Setting LOCAL SERVICE METWU Guest Administrators Ls Administrators Remete Backup Everyone LOCAL SERVIC LOCAL SERVICE Adrmini LOCAL SERVICE Fdministratorns LOCAL SERVICE METI Admineitratont Admuinistratorz 21 21 22898 87 2 5 1 5 71 21 23835 781 2 Administrators LOCAL SERVICE TWO e Guest account may be shown as indicated below Action Wiew Help e 0 X W Local Computer Policy a ge Computer Configuration E Seftware Settings Windows Settings L3 Name Resolution Policy Scripts Startup Shutdown me Deployed Pranters a By Settings Account Policies a Local Policies Audit Policy User Rights Assigemerd Security Options Wendews Fireevall with Advanced Security E Metweek List Manager Policies E Public Key Policies L3 Software Restriction Policies L3 Application Control Policies ABB IP Security Policies on Local Computer Advanced Audit Policy Caefuyaration Policy Create symbolic links Admanistrators Admanistrators SERVE ert Debug programs Dery access to thet compuber from the nebagrk Deny leg on as a batch job lallus 2 Deny log on as a sericg Deny access to this computer from the network Properties Deny log f Local Securfy Setting Exam ri Deny accesa io this computer irom the Deny log on through RI Eruble computer and
6. 5 Chapter 1 1 6 6 ScanVue 8000 Web Client Kiosk Description eret 6 ScanVue 8000 Web Client Kiosk Operation erret 7 DONO NO 7 Interactive Mode Home Web Page 7 Alternating Web Page Image FeALUEG 2 2 eau gea S ko e Pre une ioca Sen unco eut odo irte 8 Web Page Video Clip Slideshow Presentation ccccccccsssecceseeecesseccauseceseeceaeeessuseessuseesaaees 8 4 Pushbutton SWIICNGS EET RE NTRTT n 9 m m 9 Configuration Example RE ET DTE 10 ScanVue 8000 Web Client Kiosk Models rere 11 Available MP TTE TT 11 ro D NI 12 UR RENI 13 Interactive Device Options 14 ScanVue Accessories 14 Chapter 2 Gemino Stated ETE EE OT 15 Pant 1 SDK Installati n TRENTON 16 Hardware and Software
7. Feace shutdown from a Generate security uditi impersonate a cient aff increase proceeds work Increase scheduling Load and unioad Lock pages in memory Leg on as a batch job Leg on Manage auditing and 1 Modify an object label Poticy based QoS 71 Admirastratros Templates a gl User Configuration Modify firmware ema Perform volurne maini e With SVSERVE Guest highlighted click Remove to remove Guest then click OK e Close Local Group Policy Editor Network setup is completed 14 May 2015 Rev B 23 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Part 3 Demo Mode Test Description In the default Demo Mode configuration the ScanVue Kiosk will boot to the internal home pages HomeURL Default URL http localhost index1 html and HomeURL2 Default URL http localhost index2 html The ScanVue Kiosk will then be ready to accept the demo barcode scans and button presses while two home pages are cycled between two graphic images The touch screen is active to demonstrate functionality For units that have been re configured scan the Return to Factory Defaults barcode tag then the Save and Reboot tag which will return the ScanVue Web Client Kiosk to its factory default Demo Mode operation Instructions ocan sample barcodes shown below and verify represented sample graphic images The internal local web server application will look
8. May 2015 Rev B 21 ScanVue Interactive Web Client Kiosk User Manual M8000 02 e Click Turn On button to enable Guest account feces ES 3 Control Panel Control Panel tems User Accounts Manage Accounts Turn on Guest Account ty Search Contrat Pone Do you want to turn on the quest account yeu tum ea the guest account people who do net have an account can ubt the quet account log ente The computer Pagieeerd protected filer or petting not acomsible te ques e Guest account should then be indicated as follows Choose the account you would like to change john l m Administrator E Guest m l Paspword protected Guest account Create a mew aczeunt What user account Additional things you can do Set up Parental Controls Go to the main User Accounts page e Close the Manage Accounts window 14 May 2015 Rev B 22 ScanVue Interactive Web Client Kiosk User Manual M8000 02 5 Allow ScanVue Guest Account on Host Server Network For Windows 7 Guest account is denied access on the network by default This process removes Guest as a denied account from network server security settings policy e Click Start e n Search programs and files field type and enter GPEDIT MSC The Local Group Policy Editor will open Enter Computer Configuration Windows Settings Security Settings gt Local P
9. Network Mask UMAAAAAAAA IP Sub net mask 255 255 0 0 Network Password WPLSS S Used to connect to the file server 31 characters Not Set Network Name NNLSS S ESS ID network name for wireless networks INSTALL DNS IP DNAAAAAAAA IP Address of DNS Not Set Gateway IP GWAAAAAAAA IP Address for routed or segmented networks Not Set WINS Server IP WWAAAAAAAA Required for Windows networking Not Set Product Info Timeout Duration secs product information is shown Wireless RF WN0001 Selects wireless RF mode Wireless T otherwise F 10baseT Ethernet WNOOO0 Selects hard wired Ethernet HardwiredzT otherwise F Save Configuration KQ0003 Save configuration in EEPROM BIN file amp reboot Factory defaults IN123456789 ocan twice restores factory default configuration werten mom seen stoves noord mm Table 1 Barcode Configuration Labels Barcode Configuration Label Notes IP addresses are in hex notation Each of the quads in the address becomes a pair of hex digits e g 10 0 0 10 is encoded as 0A000004 String values start with the count of characters L followed by the characters of the string SSSSSSS ScanVue preserves the case of characters in strings even if it is not meaningful to the network or host The length field is always 2 digits i e 3 must be 03 5 Numerical values L and NNNQ are decimal Numerical values must be followed
10. a button down button up event pair If the cursor is positioned over a hyperlink on the page it is displaying the browser will attempt to follow that link 14 May 2015 Rev B 9 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Configuration Example Default Configuration for Demo The ScanVue Web Client is shipped configured in Demo Mode Refer to Demo Mode section Default Settings are as follows eventStart 0000003F HomeURL http localhost index1 html HomeURL2 http ocalhost index2 html URLPrefix http localhost barcode php val btPrefix http localhost buttons php val btSuffix Not Set The example above puts the ScanVue Web Client into internal Demo Mode With HomeURL specified ScanVue Web Client expects to find the embedded web page to load and display Test Example Configuration Web Page Interactive Mode Operation eventStart 0000003F HomeURL http 10 0 10 13 SV8000 html HomeURL2 http 10 0 10 13 8V8000 2 html URLPrefix http 10 0 10 13 barcode php val btPrefix http 10 0 10 13 buttons php val btSuffix Not Set The example above puts the ScanVue Web Client into Interactive Mode which is the interface between the user customer and the Web Client A retail store unit for example running a product item price verifier loyalty program gift registry and other retail applications will be operating in this mode With HomeURL specified ScanVue Web Client expects to fin
11. and Ethernet Models 11 29 VDC 10 W typ 24 VDC Nominal e PoE Hardwired Models 48 VDC 10 W typ IEEE 802 3af compliant Communication Options 11Mbps IEEE 802 11b Wi Fi e Ethernet 10 100 Base T e Power over Ethernet PoE Interactive Devices e 4 front panel push button interactive switches e Resistive touch screen Input Device Options An external RS232 serial port is available via an optional Y cable that supports a serial receipt printer or other serial device 2 USB ports For any desired future use such as MSR please contact Sales 1D 2D Barcode Scanner e Supports any 1D and 2D bar codes including PDF417 codes UPC and NCR prefix support Web Client Kiosk OS e Embedded Linux Web Page Image Support e Image Format GIF JPEG PNG Image Resolution 800x600 or lower e Animated GIF Clip Resolution 640x480 or lower e Animated GIF Image Memory 4 MB Input Data Steering e Configurable URL for each device type Configuration Setup e OnLine UnitConfig e Off Line Barcodes Web Application e Standard HTML 4 0 Javascript PHP Security WEP e WPA WPA PSK TKIP e WPA2 WPA PSK CCMP Tools SDK software developers kit includes ScanVue configuration programs UnitConfig and Modeset Sample code sample graphic image files and user manual WEP Wireless Equivalent Privacy encryption continues to be supported by ScanVue however the recommended solution to WEP
12. be preferred but is not recommended due to possible LCD image persistence pixel discoloration e Once the home page loads control resides primarily with the web server application The Web Clients page display will persist until the either web server directs it to another page a new URL is generated by scanning a barcode pressing a pushbutton or the POStimeout value is exceeded in which case it will return to the homepage Item Barcode Scan During normal operation Interactive Mode customer scans product UPC barcode generating a URL with the UPC number merged with the scanner prefix and suffix specified This unique URL is used to lookup and retrieve the specific items properties The Web Server based product price and description information in the form of SVGA 800x600 images or smaller sized images are then displayed on the ScanVue Web Client e Scanning a barcoded item generates a URL with the SKU or UPC merged with the scanner prefix and suffix specified This unique URL can be used to lookup and retrieve the specific items properties from a table For example the URL http mysite pricelookup 123456B html will be directed to the mysite domain pricelookup directory The application will retrieve the price and description data for item 123456B format it and display its contents In this example URLprefix mysite pricelookup URLsuffix html and the item SKU or UPC barcode 123456B 14 May 2015 Rev B 7 ScanVue Interacti
13. router or switch a crossover cable must be used ScanVue Factory default network settings IP Address via DHCP Username GUEST Sub Net Mask 255 255 0 0 Windows Serv SVSERVE WINSserverlP 10 0 10 13 password Not Set Unit ID ScanVue 14 May 2015 Rev B 18 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Network Setup Example Procedure Windows 7 1 Preliminary e Disable your Windows 7 Firewall or Anti Virus 2 Network Security Settings e Enter Control Panel gt All Control Panel Items gt Network and Sharing Center e Under View your active networks section click Local Area Connection Kee 22 Control Panel AllControlPanelitem Network and Sharing Center Fie Eda Help Panel Herne r i r i View your basic network information and set up connections Change adapter settings A E x ha Cha du d sh i dE WINDOWS Network 8 Internet The computes nw your ackree networks Hetwork amp type He intemet access Public network Connection H Local Ares Connection Change your networking settings Ma up er Setup wireless braadbarsd dil up ad hcc or VPH er set up router or access poe Ei Connect to network Connect or reconnect to a wereless wired ial up ar VPN netecek comnecteen Cheese h megreup and shanna apie Access files and pointers located on other network
14. router or switch or a crossover network patch cable when connecting directly to Host Server e IEE ScanVue 8000 Web Client Kiosk SDK ScanVue Documentation Access Instructions Please follow link for available ScanVue Web Client Kiosk documentation and Software Developers Kit SDK from IEE web site http ieeinc com downloads 1 To download Software Developer s Kit for setting up a PC as ScanVue Station Server with utilities click on SDK 8000 WC zip and save to your choice directory 2 Extract all files from SDK 8000 WC zip 3 Refer to SDK Contents section for description of folders and their contents SDK Files and Software Installation Before installing the ScanVue programs IEE highly recommends installing the latest updates or service packs to the operating system you are using 1 Copy the entire POS folder into directory on your host system or any other folder you choose 2 Refer to instructions described in Part 2 of this Chapter to prepare the host server for communication with ScanVue 8000 Web Client Kiosk 3 Refer to instructions described in Part 3 of this Chapter to perform local demo mode test default as shipped setting using sample images internal to ScanVue Kiosk 4 Referto instructions described in Part 4 of this Chapter to perform home web page test using sample script files and images located on host server htdocs folder copied from SDK htdocs kiosk folder 14 May 2015 Rev B 16 Scan
15. security problems is to switch to WPA2 Wi Fi Protected Access 14 May 2015 Rev B 13 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Interactive Device Options e Fujitsu model FP 1000 thermal 3 receipt printer Contact IEE Sales for this option Serial RS 232 communication Requires optional Y cable The printer is powered separately Serial RS 232 Communication ScanVue receives pre formatted data and control codes from a printer driver resident on the network host which it passes unmodified through DIN 8 Connector Serial RS 232 to the printer Default Communication is 9600 BAUD 8 bit no Parity and 1 stop bit e USB Magnetic stripe reader Contact IEE Sales for this option ScanVue Accessories 12 VDC 2 5A 30W Power Supply IEE P N 39055 01 with a standard 8 pin DIN male connector to power ScanVue Typically not included with ScanVue The input is universal 90 264VAC 50 60Hz and the power supply has global certifications e 48 VDC 10 W typ IEEE 802 3af compliant Power Over Ethernet PoE Injector IEE P N 90180 01 with dual RJ45 jacks J2 Ethernet IN J1 Power Ethernet OUT to ScanVue Typically not included with ScanVue The input is 100 250VAC 47 63Hz e Printer interface cable for Fujitsu model FP 1000 or equivalent printer IEE P N 38578 01 e Y cable for ScanVue with Fujitsu model FP 1000 or equivalent printer IEE P N 70665 01 e Y cable RS232 Universal wit
16. 10 0 10 13 GUEST Not Set 10 0 10 13 Not Set 1283 The IP address of the unit in standard IP dotted notation Configuration Notes Figure 5 Unit Configuration UnitConfig Screen 1 Mode names are NOT case sensitive 2 Set DHCP in unitIP to change to via DHCP for ScanVue to obtain an IP Address from a network DHCP server 3 Most modes can be set to factory default or Not Set value by entering double quote value 14 May 2015 Rev B 31 User Manual M8000 02 LIE Refresh Restart Unit Exit or default as the ScanVue Interactive Web Client Kiosk User Manual M8000 02 Modeset Program Modeset a DOS command line program associated with UnitConfig may be used in place UnitConfig to query and set modes via a batch program file or directly from the DOS prompt Examples The following command sets ScanVue unit IP address 10 0 30 134 to values within TESTO1 INI file then commits change to memory and restarts ScanVue modeset s fTESTO 1 INI c r 10 0 30 134 The following command sets ScanVue to specific value Wireless TRUE modeset iWireless True 10 0 30 134 Modeset command can also be used to batch program a group of ScanVue units at one time Refer to Modeset Example folder in the SDK Modeset command by itself lists all non hidden modes and their values ModeSet Options ModeSet options IPAddress v verbose operation s set modes according to mode
17. Power Serial DIN8F D Sub 25 Pin Female Connector PIN NO FUNCTION 7 PIN NO POE 2 SIGNAL GROUND EE 12 VDC 2 5A TXD RS 232C TXD RS 232C Citizen CBM 1000II Fujitsu FP 1000 ScanVue Power Serial DIN8F Pinout or equivalent printer PIN 2 PIN 1 PIN 6 PIN 7 serial Printer Cable 38578 01 DIN8M PIN NO FUNCTION Printer Cable DINSM Pinout SIGNAL GROUND INTERNAL CONNECTION RXD RS 232C DTR RS 232C DSR RS 232C TXD RS 232C INTERNAL CONNECTION Optional for Citizen 10001 INTERNAL CONNECTION Fujitsu FP 1000 or equivalent printer Figure 8 Interface Connector Pin Assignments 14 May 2015 Rev B 41 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Appendix A Configuring with Barcodes Barcode Scanner Settings The default settings of the barcode reader are preset for capturing any 1D and 2D bar codes including PDF417 codes Refer to Scanner Prefix ID Bar Codes sheet for UPC and NCR prefix enable disable barcodes Configuring ScanVue ScanVue can be configured for the network by scanning barcodes with its barcode scanner instead of sending the commands over the network Create barcode labels in Code128 containing the network information as shown in Table 1 A program such as B Coder Lite or B Coder Pro from Taltech or Avery Label Pro can create these for you On line barcode generators can also be used such as www barco
18. ScanVue Interactive Web Client Kiosk User Manual M8000 02 ScanVue 8000 Customer Interactive Web Client Kiosk User Manual Welcome to Good Sports U S Patent No 6 213 394 B1 IEE INC 7 23 Kester Avenue Van Nuys CA 91409 14 May 2015 Rev B 1 ScanVue Interactive Web Client Kiosk User Manual M8000 02 NOTICES This document contains proprietary information shall not be used or reproduced or its contents disclosed in whole or in part without the prior written consent of IEE Inc IEE Inc reserves the right to make improvements to the software described in this documentation at any time and without notice The information contained herein is subject to change without notice and should not be construed as a commitment by IEE Inc The software described in this document is provided as a licensed item in conjunction with IEE Inc equipment It may not be copied or distributed for use on other than the machines it was licensed for DISCLAIMER OF ALL LIABILITIES IEE Inc shall have no liability or responsibility to you or any other person or entity with respect to any liability loss or damage caused or alleged to be caused directly or indirectly by this documentation or the hardware or software described in it This includes but is not limited to any interruption of service loss of business or anticipatory profits or consequential damages resulting from the use or operation of such software or computer programs
19. Vue Interactive Web Client Kiosk User Manual M8000 02 SDK Contents Documentation Folder Contains Manual and support documentation POS Folder UnitConfig A GUI program used for setting up ScanVue from the network Written in VisualBasic the exe VB sources and an OCX are provided When installed the program has a wrench logo Modeset is the associated DOS program modeset exe Command line utility for setting ScanVue modes instead of UnitConfig Also named ms exe htdocs kiosk Folder Contains support folders sample test images and sample HTML and php scripts to be copied into Host Web Server htdocs directory for test purposes Test Directory c program files apache software foundation apache 2 0 htdocs Application Examples Folder Modeset Examples Contains DOS command line batch program examples using Modeset utility that can be used to configure a group of ScanVue units at one time UnitConfig Driver Installation Win7 Folde Windows 7 UnitConfig Driver Installation pdf Driver registration procedure required for running UnitConfig and Modeset programs on Windows 7 32 Bit and 64 Bit OS 32 Bit OS Drivers richtxt32 0cx Files required to be registered in Win7 64Bit OS msflxgrd ocx to run the UnitConfig program comdig32 ocx Files registered are located in directory c windows system32 64 Bit OS Drivers richtxt32 0cx Files required to be registered in Win7 64Bit OS msflxgrd ocx to run the UnitCon
20. able Unit Identification Configuration Mode Description Defaut UnitlD The host name of the unit 19 characters maximum UnitIP The IP address of the unit in standard IP dotted notation via DHCP Unit IP default is 192 168 0 1 with no connection and with OF no DHCP server available 192 168 0 1 UnitMask The network mask for the unit in standard IP dotted 255 255 0 0 notation GatewayIP The IP address of the gateway machine in standard IP 10 0 10 13 dotted notation Required only if access to the various hosts must be routed on the LAN UserName The username ScanVue uses when logging into the file GUEST server The password ScanVue uses when logging into the file Not Set server 14 May 2015 Rev B 33 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Web URL Confiquration Configuration Mode Description Defaut HomeURL HomeURL2 Complete URL defining the primary home or start page http localhost Must be a valid web page Typically this page might load dex html an animated GIF slideshow With default HomeURL the Web Client cycles between HomeURL and HomeURL2 Be sure to include the port number if other than port 80 or 443 for https lookups as in http mysite com 83 Example http mysite com index html Complete URL defining the secondary home or start http localhost page Must be a valid web page Typically this page d N might load an animated GIF slideshow Wi
21. activation EventEnd Not Required 0000000 Port2Function Changes the function of the external RS232 port Port SCANNER parameters are fixed for each device Value The port passes data transparently in both directions ScanVue buffers all input characters until CR or LF received then sends entire string of characters to host The port function can be changed with the UnitConfig utility OUTPUT Printer 9600 baud 8 data no parity 1 stop Output BIDIRECTIONAL Printer 19200 baud 8 data no parity 1 stop In Out Port3Function Changes the function of the second external RS232 port unknown 3 This physical port does not exist but the settings are used for optional devices Port parameters are fixed for each device Value The port passes data transparently in both directions ScanVue buffers all input characters until CR or LF received then sends entire string of characters to host The port function can be changed with the UnitConfig utility NONE Disabled 14 May 2015 Rev B 36 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Wireless Network Setup Each wireless RF router or access point has a network name called an ESSID that consists of up to 32 letters and numbers ScanVue 5000 is shipped from the factory configured with a factory set ESSID NetworkName Before communicating with the wireless router or access point ScanVue 5000 must have a matching case sensitive ESSID entered
22. ation Model Number Scheme Model XXXX XXXX XX 1st 4 Digits Model 8000 Series XXXX XXXX XX 8000 LCD 8 SVGA Display 2nd 4 Digits ScanVue Configuration Options XXXX 0 X 1 0 XX Wi Fi 0 No 1 Yes Last Digit Special Order XXXX XXXX X X OPTIONAL Printer Kit 2 Custom Color X Please contact IEE Sales for custom color or special request requirements ScanVue Web Client models are available with Power Over Ethernet PoE 10 100 BaseT communication or Ethernet with power input for 11 29 VDC power A 12 VDC 2 5A 30W Power Supply is available as an option Available Options Available device options are Serial Printer and Magnetic Stripe Reader MSR For device option requirements refer to Interactive Device Options section For power and communication requirements refer to Specifications section 14 May 2015 Rev B 11 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Configuration ScanVue Confiquration Options There are 2 ways to configure a ScanVue unit 1 Commands sent across the network using the UnitConfig or Modeset programs ScanVue must be able to communicate with the server on the network before configuration settings can be changed on the network 2 Scan special purpose configuration barcodes Refer to Appendix A for instructions UnitConfig the graphical table oriented version of modeset provides the easiest way to change the configuration of a unit on the net
23. by non digit character Purely numerical parameters e g Product Info Port should be followed by an upper case alpha character to prevent confusion caused by check characters and stop codes Setting the Host name also sets SMB file access mode Setting the File Server IP also sets FTP file access modes Command barcodes must be at least six characters long including the two character prefix but excluding the check character and any start and stop characters Extra padding characters may be added to guarantee this Padding characters should be upper case alpha characters and are ignored Numerical values may be zero padded e g 0001 instead of 1 The following single and paired characters should NOT be used in barcodes A F EO FF B1 B2 B3 14 May 2015 Rev B 43 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Support Barcodes INFO SCREEN BAR CODES Info Screen 1 Info Screen 2 150001 150002 CONFIGURATION BAR CODES Save Settings and Reboot Unit IP via DHCP UIFFFFFFFF Hardwired Network Wireless HNG668 HNG661 IEE DEFAULT BAR CODES Factory Default Settings Reboot Only IN123456789 IN987654321 Note Scan Twice Note Scan Twice 14 May 2015 Rev B 44 ScanVue Interactive Web Client Kiosk User Manual M8000 02 SCANNER PREFIX ID ENABLE BAR CODES Enable UPC prefix IDs Enable NCR prefix IDs A 003324 CC0D3332 When enabled the scanner When enabl
24. clips when directed to the host web server network by entering URL s using IEE configuration program UnitConfig or Modeset ScanVue 8000 Web Client Kiosk Description ScanVue 8000 Web Client Kiosk is a mini kiosk designed to scan bar coded merchandise obtain and display current in store promotional information Retail consumers are provided this information to help make informed purchasing decisions The SVGA 800x600 pixel resolution display can be used to present in store merchandising and multimedia presentations for promoting seasonal sales and upcoming events to help retail consumers make informed purchasing decisions The programmable function buttons and touch screen enhance in store applications allowing for customer interaction Image formats supported are GIF JPEG and PNG Short animated GIF clips 640x480 resolution or lower are also supported Content developers are encouraged to use familiar design tools such as HTML JavaScript and PHP scripts to create images and interactive applications ScanVue Web Client Kiosk is a network connected device supporting 10 100 Base T Ethernet Power Over Ethernet PoE and 11Mbps IEEE 802 11b Wi Fi communication The contemporary housing design merges well with almost any store d cor and custom color combinations are available if the units are ordered in sufficient quantities The electronics package is completely contained in a high impact ABS injection molded case 14 Ma
25. computer or chamge sharing settings zm Troubleshoot problems Diagnose and repair metwork problemas ex get troubleshooting infcematesn HomeGroup Internet Windies Feras e Verify network communication is established with status similar to the following example Note Host Server obtains IP address from router DHCP server referenced in example as IPv4 Address 10 0 10 79 SS Control Panel Control Panel items Network and Sharing Center File Edit View Tools Help Control Panel Home View your basic network information and set up connections Change adapter settings T x e h N h po WINDOWS Network 8 Internet 9s This computer View your active networks E Network 8 Access type No Internet access Public network Connections 9 Local Ares Connection Change your networking settings Local Area Connection Status Set up new connection oF network General lt L Set up a wireless broadband dial up ad hoc or VPN Connection Connect to a network IPv4 Comectvity Connect or reconnect to wireless wired dial up of v6 Commectvity Meda State S 00 ons Duration Access files and printers located on other network ed Speed choose homegroup and sharing options Troubleshoot problems Network Connection Details Diagnose and repair network problems or get troub HomeGroup Mes Connection specfic DN D
26. d the host server web page to load and display HomeURL must be set to start web page for producing primary image or animated GIF clip HomeURL2 if used is set to secondary web page for producing alternate image or animated GIF clip Customer scans product UPC barcode generating a URL with the UPC number merged with the scanner prefix and suffix specified This unique URL is used to lookup and retrieve the specific items properties from a table The Web Server based product price and description information in the form of SVGA 800x600 images are then displayed on the ScanVue Web Client Changing a mode setting value using UnitConfig modifies the saved configuration ScanVue retains the new settings in non volatile memory The ScanVue Web Client supports input devices barcode scanner pushbuttons digital touch screen and optional magnetic stripe reader 14 May 2015 Rev B 10 ScanVue Interactive Web Client Kiosk User Manual M8000 02 ScanVue 8000 Web Client Kiosk Models ScanVue Model 8000 Web Client Kiosk is available with a SVGA color graphics LCD display The ScanVue LCD family consists of a number of different models that appear externally identical but have different features The ScanVue Web Client Kiosk model 8000 0010 is basic model with 10 100 BaseT Ethernet communication The ScanVue Web Client Kiosk model 8000 0110 has 11Mbps IEEE 802 11b Wi Fi communication along with 10 100 BaseT Ethernet communic
27. desinc com generator index php www nationwidebarcode com barcode generator Follow the step by step procedure outlined in the following pages to configure ScanVue using barcodes 1 Power up the ScanVue unit Wait until it finishes booting the 2 blue info screens have been displayed and the IEE logo clears If you have an RF unit a red connection diagnostic screen may appear if the unit doesn t connect to your network Either way you are ready to reconfigure 2 Scan the specific labels listed in Table 4 required to change the configuration to your network s parameters ScanVue will display the raw code then the setup name and entered value 3 When all the setup labels have been scanned in and visually verified scan the following Bar code Save Settings and Reboot This causes the complete configuration setup to be written to ScanVue non volatile memory and reboots for the changes to take effect Save Settings and Reboot 4 fitis required that you need to change barcode scanner configuration for your application please contact IEE for Barcode Scanner configuration support 5 This completes the network configuration for ScanVue If your network servers have already been set up ScanVue will start communication with the network 14 May 2015 Rev B 42 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Mode Setting Default Setting Unit IP UIAAAAAAAA IP Address Each unit must have a unique address DHCP
28. e IEEE8021X None wpaPairwise WPA Pairwise WPA Pairwise TKIP None TKIP None None J one None WPA PSK passphrase password WPA SSH CA certificate path ex etc cert ca pem WPA SSH client certificate path ex etc cert user pem Not Set WPA SSH private key path ex etc cert user prv Not Set Not Sa WPA SSH CA certificate 2 path ex etc cert ca2 pem wpaClientCert2 WPA SSH client certificate 2 path ex Not Set etc cert user pem wpaPrivateKey2 WPA SSH private key 2 path ex etc cert user prv Not Set wpaPrivateKey2Passwd WPA private key 2 password 14 May 2015 Rev B 35 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Miscellaneous Configuration Configuration Mode Description Defaut Wireless TRUE sets ScanVue communications to wireless RF FALSE FALSE sets communications to 10baseT Ethernet EventStart An 8 character string of hex digits 32 bit mask which 0000000F enables starting events for a specific device as defined in the table below F results in all pushbuttons set active Mode Value mask setting Disable mask 00000000 Pushbutton 0 leftmost 00000001 Pushbutton 1 2 from left 00000002 Pushbutton 2 3 lt from left 00000004 Pushbutton 3 rightmost 00000008 Each button press generates message tokens with a similar message packet structure called EVENTS Start event mask defines the beginning of a device
29. e selected key must match the type of encryption selected For example if WEPEncryption is set to SHARED128 and WEPKeyIndex is set to WEPkey2 then WEPkey2 must contain 26 hex digits or 128 bits WEPkeyindex and the encryption data can be set by barcode WPA and WPA2 Encryption Settings ScanVue supports Wi Fi Protected Access WPA and WPA2 802 11i The UnitConfig program provides the user interface to setup various WPA mode s for ScanVue s radio Example ScanVue settings are shown in the table below For additional security requirements refer to Wireless Encryption Configuration table located in ScanVue Supported Modes section WPA TKIP UseWPA TRUE WPA2 AES wpakeyMgmnt WPA PSK wpakeyMgmnt WPA PSK TKIP CCMP TKIP CCMP Figure 6 Example WPA WPA 2 Encryption Settings po wpaScanSsid TRUE wpaScanSsid TRUE po po po 14 May 2015 Rev B 37 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 5 Interactive Device Options ScanVue options available are Serial Printer and Magnetic Stripe Reader MSR Serial Receipt Printer Serial printer support is available as an option ScanVue provides support for the following or equivalent external serial receipt printer model Fujitsu model FP 1000 Contact IEE Sales for this option Configuring the Serial Port For serial printer communication serial port 2 Configuration Mode port2function must be set
30. ed the scanner will transmit a prefix before will transmit a prefix before any UPC EAN bar code the following code types The prefixes are as follows UPC A UPC E The prefixes are as follows FF EAN 8 13 UPC E B1 Code 39 F EAN 13 and B2 ITF and FF EAN 8 B3 Code 128 amp other codes Disable custom prefix IDs ee ie 003325 14 2015 45 ScanVue Interactive Web Client Kiosk User Manual M8000 02 SCANNER UPC A TO EAN 13 ENABLE CAR CODES 14 May 2015 Rev B T Unlock Settings enable UPC A to EAN 13 10159 01 Save Settings Lock Settings 46
31. ed on the Info Screen 4 Using UnitConfig or modified batch program using modeset utility see Application Examples Modeset Examples Sample Program folder in SDK change following mode settings as indicated Server IP Addr is Host Server Address HomeURL http lt Server IP Addr gt SV8000 html HomeURL2 http lt Server Addr SV8000 2 html URLPrefix http lt Server IP Addr barcode php val btPrefix http lt Server IP Addr buttons php val 5 Commit settings and reboot ScanVue If Host Server has been set up as previously instructed you should see alternating HomeURL Animated GIF Falls presentation and HomeURL2 Red Ferrari image directed by SV8000 html and SV8000 2 html script files located in htdocs directory 6 Scan sample barcodes shown on following page and verify represented sample graphic images directed by barcode php script and HTML script files located in htdocs directory 7 Press all four pushbutton switches and verify sample graphic images button1 jpg to button4 jpg for each switch directed by buttons php script file located in htdocs directory 14 May 2015 Rev B 25 ScanVue Interactive Web Client Kiosk User Manual M8000 02 HOME WEB PAGE TEST BARCODES 1 TM 14100 07458 8 70662 03014 1 TM 14 2015 26 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 3 ScanVue Connections Refer to Fi
32. ely long chain of images or a loop could be created 14 May 2015 Rev B 8 ScanVue Interactive Web Client Kiosk User Manual M8000 02 4 Pushbutton Switches The four pushbuttons are treated as four separate input devices Pushing any one of the 4 pushbuttons generates a URL with the pushbutton number merged with the btPrefix and btSuffix specified The pushbuttons are numbered 1 to 4 from left to right PushButton Value Mask Setting Push button 1 leftmost fffffffih Push button 2 2 from left fffffff2h Push button 3 39 from left fffffff4h Push button 4 rightmost fffffff8h Push button release fffffffOh For example Pressing pushbutton 2 could generate the following URL depending on settings Press pushbutton 2 http mysite com buttons php val fffffff2 Releasing pushbutton 2 could generate the following URL depending on settings Press pushbutton 2 http mysite com buttons php val fffffffO e Event Start mode setting default is 0000000F This is a bitmap indicating all 4 buttons are activated A start event will be generated when a button is pressed Refer to ScanVue Supported Modes section for EventStart requirements Touch Screen The resistive touch screen emulates a mouse and does not have URL prefix and suffix entries When the touch screen is pressed the browser internally reads the co ordinates output by the touch screen controller and positions the cursor at those coordinates It then generates
33. esorption Broadcom NetXtreme SPx Gigabit Corto Windows Firewall 3 Physical Address D0 67 E5 E5 35 40 DHCP Enabled IPv4 Address IPv4 Subnet Mask Lease Obtained Monday January 05 2015 12 38 50 PM Lease Expres Tuesday January 06 2015 12 48 55 IPv4 Defak Gateway 10 0 10 20 IPv4 DHCP Server 10 0 10 20 IPv4 DNS Server 10 0 10 20 WINS Server NetBIOS over En Yes Internet Options e Close Network and Sharing Center window 14 May 2015 Rev B 19 ScanVue Interactive Web Client Kiosk 3 Change Computer Name User Manual M8000 02 e Enter Control Panel gt All Control Panel Items gt System gt Computer tab 2 Control Panel All Control Panel Items System X Search Control Pan Edi View Jools Help Control Panel Home HP Device Manager Wy Remote settings WW System protection Hy Advanced system settings Action Center Windows Update Performance Information and Tools View basic information about your computer Windows edition Windows 7 Professional Copyright 2009 Microsoft Corporation All rights reserved Service Pack 1 Get mo System re features with a new edition of Windows 7 Manufacturer Dell Model Rating Precision T3500 n Windows Experience Index Processor Intel R Xeon R CPU W3530 280GHz 2 80 GHz Installed memory RAM 12 0 GB System type 64 bit Operating System Pen and Touch No Pen or Touch Input is available for t
34. fig program comdig32 ocx Files registered are located in directory c windows syswow64 14 May 2015 Rev B 17 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Part 2 Local PC Host Server Network Setup Introduction ScanVue 8000 Web Client Kiosk comes factory defaulted with IP address set for DHCP This is for automatically obtaining IP addresses assigned from a network server when performing installations The ScanVue will default to 192 168 0 1 if you don t have a DHCP server installed on your network This section describes how to setup a local desktop or laptop PC Host Server to communicate with a factory default ScanVue 8000 Kiosk A router is expected to be installed on your network with DHCP server enabled The Host Server must be set for Ethernet communication allowing for further configuration using IEE s configuration program UnitConfig or Modeset See Chapter 4 for ScanVue Configuration This process is specific for Windows 7 OS however Windows OS 98 NT 2000 and XP are also supported Your computer will be configured as a network server with one client If you need to set your computer back to its original settings note down all the original settings before you make the changes If your computer is already setup to operate on a private company network IEE recommends consulting with your IT group before performing this procedure Note If a ScanVue is connected directly to a PC without a
35. gure 2 for ScanVue rear connections Refer to Figure 3 for Ethernet pin assignment Refer to Figure 4 for 12Vdc power pin assignment Connections For PoE Power Communication PoE Hardwired connection requires only 1 cable e CAT 5 standard straight Ethernet cable 48 Vdc IEEE 802 3af compliant Connections For 12V Power Ethernet Communication Ethernet only non PoE connection requires 2 cables e 12 Vdc power to ScanVue DIN8F connector CAT 5 standard straight Ethernet cable to ScanVue Ethernet Interface connector or a crossover network patch cable when connecting directly to Host Server Connections For 12V Power Wi Fi 802 11b g Communication Wi Fi models require DIN8 power and hardwired Ethernet connection required for network settings configuration 12 Vdc power to ScanVue DIN8F connector CAT 5 standard straight Ethernet cable to ScanVue Ethernet Interface connector or a crossover network patch cable when connecting directly to Host Server Figure 2 Connector Location Rear of ScanVue 14 May 2015 Rev B 27 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Ethernet PoE Connector RJ45 Pin Assignments The following table identifies the locations for the Ethernet port pins and PoE power pins if used Ethernet RJ45 Pin Assignment 8 Pin HJ45 Pinout PIN NO FUNCTION mM Pin 8 Pin 1 Figure 3 Ethernet PoE Connector RJ45 Pin As
36. h DB9F connector IEE P N 38516 07 6 DC power extender cable with DIN8F to DIN8M connectors IEE P N 37082 72 14 May 2015 Rev B 14 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 2 Getting Started This Chapter describes how to set up and operate a factory default IEE ScanVue 8000 Web Client Kiosk on your laptop or desktop PC Host Server Several programs are installed that let you demonstrate the capabilities of the ScanVue 8000 Web Client Kiosk and make use of the tools and utilities provided in the SDK package downloaded from IEE s web site These programs can be used as demonstration tools Part of the process is to change the network settings of your computer so that it can communicate with a factory default ScanVue 8000 Web Client Kiosk If you need to set your computer back to its original settings note down all the original settings before you make the changes If your computer is already setup to operate on a private company network IEE recommends consulting with your IT group before performing this procedure 14 May 2015 Rev B 15 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Part 1 SDK Installation Hardware and Software Required Laptop or desktop computer with Windows 98 Me 2000 NT XP Pro 7 LAN system with TCP IP network protocol Router or switch for connecting ScanVue 8000 Kiosk to network Category 5 standard straight cable when using a
37. he Set Mode button will turn red and those changes marked in red were not made Close Clicking the Close button will blank all fields allowing a new IP address for another unit to be entered Clicking the TextReset button will apply changes made to text modes so they can be seen immediately As with other modes the changes are not permanently stored until the Commit button is clicked The SaveToFile button will save the setup to a text file where it can be stored and printed if necessary This is usually done for troubleshooting or maintaining hard copy records of each unit s configuration Restart Unit The Restart Unit button will cause a soft boot of the selected unit The Exit button closes the UnitConfig program program When UnitConfig program is first started all program fields are TextReset SaveToFile 14 May 2015 Rev B 30 UnitConfig 3 4 Unit IP Address Mode Version DateTime BuildInfo ProductName SerialNumber UnitID UnitIP UnitMask GatewayIP Domain DNS WindowsServ ShareName WINSserverIP ServerType FTPServerIP UserName Password SloppiHost AlternateSloppiH SloppiPort Ll nmnt Timnas ScanVue Interactive Web Client Kiosk Set Made Close TextReset Savel oF ile Help Content New Content 9 06 19700101001919 NoBr 20141006 999999 ScanVue via DHCP 255 255 0 0 10 0 10 13 Not Set 10 0 10 13 SYSERVE POS 10 0 10 13 SMB
38. his Display Dell support Website Online support Computer name domain and workgroup settings Computer name Windows Full computer name Windows e Double click Change settings e Inthe System Properties window click Change button to bring up Computer name Domain Changes window e Enter SVSERVE in Computer name field Note Workgroup must be selected with any description provided it is 8 characters or less no spaces a Control Panel Control Panel hems File Eda Took Control Panel Home View basic information about your computer Dece Manager Windows edition Kp Remote settings Windows 7 Professional My System protection Copyright 2009 Microsoft Corporation All rights reserved My Advanced tyitem settings Service Pack 1 Det m e features System Manufacturer Modet Rating Processor Installed memory RAM 120 68 System type Pen and Touch Dell support ction Center Webste Windows Update Computer name domain and workgroup settings Pedormance Information aed Tech Computer name Ful computer name e Click OK button Dell T3500 Inte CPU WHS 28009 250 GHz 64 b amp Operating System No Pen or Touch Input is available fee this Display Workgroup SVSERVE will change to Windows after restarting this coengoter SVSERVE e Follow displayed instructions to restart computer
39. into its memory to replace the default name With ScanVue Price Verifier setup for default Ethernet Hardwired communication ESSID is typically entered using UnitConfig This name may also be entered through the ScanVue barcode reader using a user created barcode See Appendix B for creating configuration barcodes Connect the 802 11b Wi Fi router to your configuring computer LAN card with the patch cable and configure it using the manufacturers instructions The IP Address and Input Mask of the router must be in the range of your computer and ScanVue The ESSID of the router and ScanVue must match note the ESSID is case sensitive Default settings are 10 0 10 13 Mask 255 255 0 0 ESSID INSTALL ScanVue wireless encryption settings WEP WPA or WPA2 must match the router WEP Encryption Settings ScanVue5 supports 2 different tyoes of WEP Wireless Equivalent Privacy encryption in software versions 4 12 and later WEP encryption is set by the WEPEncryption mode Mode Setting Function JJ NONE WEP encryption off OPEN40 Open System 40 bit encryption OPEN128 Open System 128 bit encryption There are 4 unique encryption keys WEPKey1 through WEPKey4 Each key contains 10 hex digits for 40 bit encryption or 26 hex digits for 128 bit encryption Default value of the keys is a string of zero digits of the appropriate length The mode WEPKeyIndex determines which of the 4 keys is used The default is WEPKey1 Th
40. ng Diagram with Extension Cable Optional 1 to 1 Y Cable IEE Part No 70665 01 Optional 12 VDC 2 5A Power Supply Part No 39055 01 Printer Power Serial Su pply EN 7 Printer Optional Printer Cable Part No 38578 01 NOTE The RJ12 cable should be disconnected from printer Optional Extension Cable Part No 37082 XX XX specifies cable length Figure 7 Wiring a Serial Printer 14 May 2015 Rev B 39 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Magnetic Stripe Reader Contact IEE Sales for this option General Interactive Device Requirements When one of the input devices is activated an internal device driver converts the ASCII data read from the input device into a URL for the Web Client to send to the web server Each input device generates a unique URL as described previously That URL is opened by the Web Clients embedded browser and displayed for the POSTimeout value The HomeURL page is the exception it has no timeout assigned to it Additional pages may be linked to creating an infinitely long chain of potential responses to inputs up to the length of the POSTimeout Once POSTimeout has been reached the unit generates a call to the HomeURL again and the process repeats itself 14 May 2015 Rev B 40 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Power Serial Interface Connector DIN 8 Pin Assignments Typical Supported Serial Printer ScanVue
41. nments 28 Figure 4 Power Connector DIN8F Pin Assignments 28 Figure 5 Unit Configuration UnitConfig 31 Figure 6 Example WPA WPA 2 Encryption Settings 37 Figure 7 Wiring a Serial Printer cccccccccccsececseeeeceeecseeeeseueeseaeeeseueessaeeeseeesseeeesees 39 Figure 8 Interface Connector Pin 41 Table 1 Barcode Configuration Labels cccccsecceseececeeeeeeeeeeeeeeeseeeeeseeeesaeeesaeeesees 43 14 May 2015 Rev B 5 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 1 Introduction Overview This manual provides instructions for configuration and operation of the IEE ScanVue 8000 Interactive Web Client Kiosk Included is a description of the basic functions and features of the hardware along with a description of how to physically install the unit in its intended location set it up to operate on your specific network configure your network and interface the IEE ScanVue to a host web server The following chapters describe how to e Setup and install a local desktop or laptop PC with IEE Configuration programs Configure ScanVue using IEE configuration program UnitConfig Modeset e Display web images and short Animated GIF video
42. olicies gt User Rights Assignment Double click on Deny Access to the Computer from the Network See window below Eile Action Wiew Help nx Hm I of Local Computer Polity Computer Configuration L Software Settings Windows Settengs D Name Resolution Palicy rt Senpts Martup Shutdovwn mm Deployed Printers A Security Settings Account Policies a Local Policies Audit User Rights Asssgnanerit Security Options D Windows Firewall with Advanced Secunty Hetwork List Manager Policies 2 Public Key Policies Software Rertrictpan Policies 2 Application Control Policies 1 3 IP Security Policies on Local Computer L1 Advanced Audit Policy Configuration gy Policy based QoS C Administrative Ternplites a User Configuration Poly Adpust memory quotes fora process Allows log on locally Allow leg en through Remote Desktop Services Back up files and directores Bypass traverse checking Change the system time Change the hime zone Creste pagefile Create a token object Create global objects Create permanent shared objects Create symbolic baks Debug programs Deny access bo this c emip ter Traen te network Deny log en as a batch job Deny log en s a serae Deny lcg on Deny leg on through Remote Desktop Services Enable computer and user accourrts to be trurbed for delega Force shutdown from a remate sysbern Generate secunty audits
43. set ini commit to permanent storage restart unit when complete f specify an ini file e g fNewModes ini 1 set a single mode e g i1UnitID ScanVue5 get a single mode e g gUnitID send literal text address of unit obtained from modeset ini if not specified 14 May 2015 Rev B 32 ScanVue Interactive Web Client Kiosk User Manual M8000 02 ScanVue Web Client Kiosk Supported Modes Notes 1 Modes viewed in UnitConfig application that are NOT listed in this manual are used for other ScanVue models and do not apply to the Web Client Kiosk model 2 Mode names are NOT case sensitive Set DHCP in unitIP to change to via DHCP for ScanVue to obtain an IP Address from a network DHCP server 4 Most modes can be set to factory default or Not Set value by entering double quote or default as the value Fixed Unit Identification Configuration Mode Bescipion Default Software version number read only Not avaiable o Buildlnfo The date and time of the software release in the format YYYYMMDD YYYYMMDD read only ProductName Default ScanVue read only SerialNumber Contains the unique serial number for the unit read only 999999 QueryViaBrowser IEE factory setup Always TRUE for Web Client browser TRUE configuration Note This configuration setting is not available for ScanVue models containing software prior to version 11 01 ver 1 008 User Configur
44. signments Power Connector DIN8F Pin Assignments e The following table identifies the locations for the 12 Vdc Power pins Power DIN8F Assignment CONNECTION INTERNAL CONNECTION o rower 12 woo ess _ C 1 Figure 4 Power Connector DIN8F Pin Assignments Power DIN8F Pinout 14 May 2015 Rev B 28 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Mounting the ScanVue 8000 Web Client Kiosk Standard Wall Mount Installation The ScanVue 8000 Web Client Kiosk is VESA MIS D 100 x 100 mm standard mount supported 3 940 x 3 940 and can be mounted on any type of flat vertical surface using the four 4 threaded PEM P N ITB 032 mounting holes located on the rear using 10 32 fasteners The closest metric fastener would be M5 x 0 8 Mounting hardware is not provided as the material used in the vertical wall can vary depending on the location chosen P 8 20 6 458 VIEWING AREA 4 864 VIEWING AREA 9 12 14 2015 29 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Chapter 4 ScanVue Web Client Configuration UnitConfig Program Configuring ScanVue units over the network requires a GUI program called Unit Config or Modeset program described below Unit Config provides a simple graphical way to query and configure any ScanVue unit using mode commands Changes can also be made off line tha
45. t will allow the unit to connect to the network using Configuring with Barcodes method See Appendix A without requiring the PC Generally configuration by special barcode is kept for those occasions when a devices network configuration is incompatible with the local network Once the unit is network compatible the rest of the configuration can be done through UnitConfig Using UnitConfig Start UnitConfig b blank Buton Field m fnstrucion Unit IP Address Enter the IP address of the ScanVue unit you wish to change in the Unit IP Address field Read Modes Click the Read Modes button All the Modes and their Content values will be read from the subject unit and displayed as shown in Figure 5 Set Mode To change a mode value highlight the New Content field in the same row as the mode you want to change by clicking on it Enter the new value in the field and click the Set Mode button If the value is accepted the field and the button will turn green If it is not accepted the field and button will turn red The light color area at the bottom of the screen will display context sensitive help message for each mode as the mode is highlighted For some modes the values available are indicated in this area Now click the Commit button This will commit the change to memory in the ScanVue unit Multiple changes can be made before committing them If any of the changes are not accepted t
46. th default HomeURL the Web Client cycles between HomeURL and HomeURL2 Be sure to include the port number if other than port 80 or 443 for https lookups as in http mysite com 83 Example http mysite com index2 html HomeURL Timeout Delay in seconds between HomeURL and HomeURL2 20 oages Timeout of 20 seconds is a fixed setting URLPrefix Prefix for the barcode scanner Any legal full or partial http localhost URL is acceptable Val Example http mysite com barcode php val URLSuffix Suffix for barcode scanner Any legal URL suffix will Not Set suffice May be left blank btPrefix Prefix for 4 pushbuttons Any legal full or partial URL is http localhost acceptable Example http mysite com buttons php val btSuffix Suffix for 4 pushbuttons Any legal URL suffix will suffice Not Set May be left blank msrPrefix Prefix for Magnetic Stripe Reader MSR Any legal full or http localhost partial URL is acceptable msr php val Example http mysite com msr php val Suffix for MSR Any legal suffix will suffice May be left Not Set blank 14 May 2015 Rev B 34 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Wireless Encryption Configuration Configuration Mode Description WEPEncryption WEP Encryption Open40 Open128 Shared40 None Shared128 DRE Select the active WEP 1 4 wpakeyMgmnt WPA Key WPA EAP WEAK PSK Non
47. to OUTPUT In OUTPUT mode serial port 2 is a transparent RS232 data port The port parameters are pre configured for the co located Communication is 9600 baud 8 data bits no parity 1 stop bit Use the UnitConfig program or modeset utility to change the serial port configuration mode setting port2function to OUTPUT Printer Cable Wiring See Figure 7 for Serial Printer Wiring Diagram and Figure 8 for ScanVue power serial connector pin assignment Optional IEE cables available for printer interfacing to ScanVue Serial interface cable IEE P N 38578 01 connects to the supported serial printer D Sub 25 Pin Female serial connector e Y cable IEE P N 70665 01 breaks out the ScanVue DIN8 connector serial port for printer interface e Printer extension cable IEE P N 37082 XX where XX specifies the cable length Other manufacturers serial printers may require a different Y cable or port settings Check with IEE Sales before attempting to connect a different printer 14 May 2015 Rev B 38 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Printer Communication Contact IEE Sales for communication requirements Serial Printer Wiring Typical Optional 1 to 1 Y Cable IEE Part No 70665 01 gt Optional 12 VDC 2 5A Power Supply Part No 39055 01 Printer Serial d Printer Supply Optional Printer Cable Part No 38578 01 NOTE The RJ12 cable should be disconnected from printer Serial Printer Wiri
48. up the barcode number for the item scanned and display the graphic image or text data retrieved from the lookup tables To exit Demo Mode and setup for Interactive Mode to run on your network reconfigure the Web Client and change the HomeURL and HomeURL2 to your network home pages Refer to Interactive Mode section in Chapter 1 and Web URL Configuration section in Chapter 4 DEMO MODE TEST BARCODES Il HIM 07458 o 70 12021 5 14 2015 24 662 030 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Part 4 Home Web Interactive Mode Test Description In the Interactive Mode configuration the ScanVue Kiosk will boot to the host server web pages HomeURL and HomeURL2 The ScanVue Kiosk will then be ready to accept test barcode scans and button presses while the two home pages are cycled between the two URL pages Sample Script Image File Installation 1 Make a backup of your Host Web Server htdocs directory 2 Copy the entire htdocs kiosk folder and sub folders into htdocs folder htdocs folder will contain the example HTML and php scripts referencing sample images for the ScanVue Web Client to display Test Procedure 1 Connect ScanVue to Host Server Network as described in Chapter 3 2 Apply power the ScanVue unit will start its boot up sequence 3 During boot up and connection to Host Server note the IP address of the ScanVue report
49. ve Web Client Kiosk User Manual M8000 02 Alternating Web Page Image Feature Mode Settings HomeURL HomeURL2 Two web page images set using HomeURL and HomeURL2 mode settings using HTML and PHP script alternate during Idle Stage with programmed timeout until item barcode scan Alternating idle stage images resume after a programmed timeout Possible LCD image persistence is avoided using this feature 2 alternating graphic images can be as simple as the image below shown in complementary colors Alternating the two images every 20 seconds is default JOES HARDWARE JOES HARDWARE SCAN HERE SCAN HERE Web Page Video Clip Slideshow Presentation Mode Settings HomeURL or HomeURL2 A sequence of up to 20 animated gif images 640x480 resolution or lower set using either HomeURL or HomeURL2 mode settings using HTML and PHP script are displayed during Idle Stage simulating slideshow until item barcode scan Idle stage images resume after a programmed timeout e The animated GIF should not exceed 4 Mbyte in size Depending on the complexity of each image in the animated GIF the presentation allows for more than 20 images e f more complex images are desired a simple web server driven sequence of images can be implemented on the home page For example the home page contains a pointer to a GIF or JPEG image with a meta tag in the header specifying how long to display the page and which page to go to next An almost infinit
50. work as opposed to scanning barcodes or sending modeset DOS commands UnitConfig may be installed on a desktop or laptop computer for setting up ScanVue units without a large network complicating it You will need a network interface card NIC installed in your PC and configured properly to communicate with ScanVue Configuration Info Screens When ScanVue boots up two configuration status screens Fig 1 are sequentially displayed which show the current settings of the unit Each screen is displayed for 10 seconds then the unit will load the slideshow from the server and start running These screens can be displayed at any time by scanning Info Screen 1 and Info Screen 2 bar codes shown in Appendix A under Support Barcodes Wireless RF configurations display brown text on a light green background and hardwired Ethernet units display yellow text on a blue background Refer to Chapter 5 for detailed information on how to configure a ScanVue Figure 1 Configuration Info Screens 1 and 2 14 May 2015 Rev B 12 ScanVue Interactive Web Client Kiosk User Manual M8000 02 Specifications Display SVGA 800x600 pixel color graphics 8 Diagonal LCD display Network Server Computer Requirements MS Windows Unix Linux VAX or any other platform that runs a TCP IP network Supported Operating Systems e Windows 98 ME 2000 NT XP Windows 7 32 Bit Unix Linux and Open VMS Power Options Wi Fi
51. y 2015 Rev B 6 ScanVue Interactive Web Client Kiosk User Manual M8000 02 ScanVue 8000 Web Client Kiosk Operation Demo Mode The default as shipped setting Demo mode provides a way to showcase the ScanVue Web Clients abilities without requiring a physical connection to a host computer An internal web server with a price lookup database application loaded with several items is embedded in ScanVue Web Client Kiosk Refer to Chapter 2 Part 3 for Demo Mode Test To exit Demo Mode and setup for Interactive Mode to run on your network reconfigure the Web Client and change the HomeURL and HomeURL2 to your network home pages Refer to Interactive Mode section below and Web URL Configuration section in Chapter 4 Interactive Mode Home Web Page Image Mode Setting HomeURL Interactive Mode is the interface between the user customer and the Web Client A retail store unit for example running a product item price verifier loyalty program gift registry and other retail applications will be operating in this normal operation mode With HomeUHL specified ScanVue Web Client expects to find the host server web page to load and display Web page images or short 640x480 animated GIF clips are displayed continuously with HomeURL specified during Idle Stage until item barcode scan HTML and PHP scripts are used for presenting images and animated GIF clips Idle stage Image resumes after a programmed timeout A single image may