image

Contents

1. Labne Labnet International Inc Ce LIT MO3001 AccuPlate Analog Hotplate Stirrers Hot Plate Stirrer User Manual DO300 DO300 230V DO310 DO310 230V DO320 DO320 230V Ocioner 2014 Version O About This Manual This manual is designed to assist you in optimal usage of your new hot plate stirrer or hotplate stirrer Product Voltages Hot plates stirrers and stirrer hot plates are available in different voltages Before initial use check that the unit you received Is the correct voltage for your location Warranty Registration Filling out and mailing the attached Warranty Registration Card or submitting this infor mation online at http www labnetinternational com product warranty registration will validate the hot plate stirrer or hotplate stirrer s warranty Table of Contents Safety Information Operating Conditions Product Controls and Indicators Instructions for use Stirring and Heating Product Repair Product Maintenance and Storage Technical Specifications Accessories Product Size and Dimensions Certifications Warranty Statement Notes Safety Information This instruction manual contains important operating and maintenance instructions which must be read understood and followed by the product user Failure to use this product ac cording to this instruction manual may degrade or defeat the protection normally provided by this pro
2. For more information about where you can drop off your waste equipment please contact your local dealer from whom you originally purchased this equipment By doing so you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health Thank you Labnet International Inc Labnet 31 Mayfield Ave Edison NJ 08837 Labnet International Inc P 732 417 0700 F 732 417 1750 Email labnetinfo corning com www labnetinternational com Declaration of Conformity Number CE M3001 Labnet International Inc 31 Mayfield Ave Edison NJ 08837 USA Labnet International declares that the devices described below are in conformity with the EC directives listed In the event of unauthorized modification of any of the devices listed below this declaration becomes invalid Device Name AccuPlate Analog Hot Plate AccuPlate Analog Hot Plate amp Magnetic Stirrer AccuPlate Analog Stirrers Device Models Numbers DO300 DO300 230V DO310 DO310 230V DO320 DO320 230V Relevant EC Directives Low Voltage Directive 73 23 EEC As amended by 93 68 EEC EMC Directive 89 336 EEC As amended by 92 31 EEC and 93 68 EEC RoHS Directive 2011 65 EU WEEE 2012 19 EU Harmonized Standards IEC 61010 1 2001 Second Edition IEC 61010 2 010 2003 2 Edition EN 61010 2 051 2003 27 Edition EN 61326 1 EN 61000 3 2 EN 61000 3 3 EN 6
3. 1 Turn temperature and speed to zero before plugging in And connect the Main power cord topower supply Place your container or heating bath with the magnetic stirrer bar Stirrer bar should be placed in center of hot plate 2 Turn Power Switch ON Stirring Instructions D0310 D0320 1 Fill vessel with solution to be stirred Place stir bar into vessel Turn power switch ON Then Hot Top Indicator Lamp will illuminate Turn Stir Control Knob until the desired speed Speed On Indicator Lamp will illuminate when the motor runs Heating and stirring can be performed simultaneously on the D0320 models which offer both heating and stirring functions 7 When the desired stirring is complete turn the Stir Control Knob to 0 position Allow stir bar to cease rotation before removing the vessel from the unit 8 Disconnect Main power cord from the unit 9 Keep the product dry and clean disconnecting Main power cord when the unit is not used for a long time Ou Ps UY N Note 1 Range of speed control 100 1500 RPM 2 Speed control knob in extreme left CCW position stops operating 3 If motor does not run upon turning the knob increasing until 100rpm or more Please note that the viscosity of the stirred material will affect the ability of the stir bar to remain coupled to the rotating ring magnet Materials of high viscosity must be stirred at slower speed settings AccuPLATE ANALOG HOTPLATE STIRRER TEMP
4. carrier ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION OF 24 MONTHS FROM THE ORIGINAL DATE OF PURCHASE LABNET INTERNATIONAL INC S SOLE OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT AT LABNET INTERNATIONAL INC DISCRETION OF A DEFECTIVE PRODUCT LABNET INTERNATIONAL INC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE COMMERCIAL LOSS OR ANY OTHER DAMAGES RESULTING FROM THE USE OF THIS PRODUCT Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or conse quential damages This warranty gives you specific legal rights You may have other rights which vary from state to state No individual may accept for or on behalf of Labnet International Inc any other obligation of liability or extend the period of this warranty Mail Warranty Registration to or Register online at Labnet International Inc www labnetinternational com 31 Mayfield Ave Edison NJ 08837 3 lt cut along the dotted line To validate the warranty complete and return this card within 10 days Model Serial No Date Tested Date Rec d PO Name Title Phone City State Zip Postal Code Country Purchased from distributor How would you rate the quality of this product Excellent Good Fair Poor What feature s on this product made you p
5. replacement power cords avail able from Labnet or authorized Labnet product distributors Top Plate e The top plate may break during use if not properly maintained e Keep the top plate clean A nonabrasive cleaner may be used to clean the top plate e Inspect the top plate for damage during cleaning e Discontinue product use if the top plate is chipped etched or shows excessive scratching e Contact your Labnet Distributor or Labnet Customer Service for top plate replacement General e Itis important to keep this product dry and clean e Remove minor exterior liquid spills promptly e Clean exterior surfaces with a nonabrasive cleaner Do not clean this product with substances such as alcohol or benzene Use neutral detergent Do not reconnect product to power input until all cleaned surfaces have dried e If liquid or wet solid material gets inside the product immediately disconnect power to the product and discontinue use Contact Labnet for additional instructions regarding interior spills e Do not disassemble modify revise or repair this product This may be a cause a malfunction electrical fire e We recommend to store the item and its components in its original box or a similar container that offers adequate protection against damage in transit Tape the box securely Technical Specifications DO300 DO310 DO320 Hot plate Magnetic Stirrer Hotplate Stirrer Temperature Range Max 380 C
6. 1000 4 2 EN 61000 4 3 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 1 1 Date October 7 2014 fall Peter Will Labnet Product Line Manager Labnet International Inc 10 LIT M03001 October 2014 Version 1 0 LIMITED WARRANTY Labnet International Inc warrants that this product will be free from defects in material and workmanship for a period of two 2 years from date of purchase This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual Should this product require service contact Labnet International Inc s Service department at 732 417 0700 to receive a return authorization number and shipping instructions Products received without proper authorization will be returned All items returned for service should be sent postage prepaid in the original packaging or other suitable carton padded to avoid damage Labnet International Inc will not be responsible for damage incurred by improper packaging Labnet International Inc may elect for onsite service for larger equipment This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material or workmanship This warranty does not cover motor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation
7. ERATURE G SPEED RPM 800 600 Lome 000 4004 1200 1 HOT TOP Y 400 Labnet international Inc Analog Hotplate Stirrer Hot Top Indicator Lamp Heat Control Knob Temperature On Indicator Lamp Speed On Indicator Lamp Stir Control Knob Heating Instructions D0300 D0320 1 Fill vessel with solution to be heated If using a D0320 and the stirring function place stir bar into vessel Place vessel in the center of the top surface Turn power switch ON Then Hot Top Indicator Lamp will illuminate Heat Control Knob until the desired temperature Temperature Indicator Lamp will illuminate when the heater runs When the desired heating is complete turn the Heat Control Knob to 0 position And remove the vessel from the unit Disconnect Main power cord from the unit 9 Keep the product dry and clean disconnecting Main power cord when tehn unit is not used for a long time NOW a UY N 00 A Caution The Hot Top Indicator will turn OFF when the power switch is OFF even if the temperature of the top surface is still hot to touch Product Repair There are no direct user serviceable components inside this series of products Please contact you Labnet Distributor for repair or maintenance issues Product Maintenance and Storage A Caution Disconnect the plug before cleaning Power Inspect the power cord regularly and replace if damaged Use only
8. Max 380 C Display Scale temperature Scale temperature Controller Analog temperature controller Analog temperature controller Watts 680W 15W 695W Speed 100 1500 rpm Scale rpm Stirring Speed display Capacity up to 5L Feedback control Speed Controller Top Plate Ceramic coated top plate 180 X 180 200 X 310 X 107 mm AC 110V 50 60Hz or 220V 50 60Hz Plate area mm Overall WxDxH Electrical Supply Dimensions Product Codes and Accessories Product Code DO320 DO310 DO300 DO320 230V D0310 230V DO300 230V Product Code DO300 SR Description Hot Plate amp Magnetic Stirrer 120V Magnetic Stirrer 120V Hot Plate 120V Hot Plate amp Magnetic Stirrer 230V Magnetic Stirrer 230V Hot Plate 230V Accessories Support Rod included w D0320 amp D0300 EQUIPMENT DISPOSAL This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted waste Instead it s your responsibility to correctly dispose of your equipment at lifecycle end by handing it over to an authorized facility for separate collection and recycling It s also you responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of the RR equipment
9. duct Read this instruction manual prior to product use and keep this instruction manual for future reference The precautions are composed of DANGER WARNING and CAU TION Product Symbols Indicates a potentially or imminently hazardous situation which if not DANGER PO avoided could result in death or serious injury Is used to alert operators to an operating procedure Pratice or condition WARNING oy that if not strictly observed can result in severe injury or loss of life A CAUTION Indicates a potentially hazardous situation that may result in minor or moderate injury AN AN warnna A CAUTION Touching the reactor block surfaces and vials Hot Surface while hot can cause serious burns ZN warna A CAUTION This product requires a protective earth connection If not provided with a plug on a cord connect positive earth to this terminal Protective Earth Ground Warnings Personal Injury e Do not use this product in a manner other than as stated in the Operating Conditions section of this manual as the protection provided by the equipment may be impaired e This product is designed for use in laboratory environments by persons knowledgeable in safe laboratory practices e Always wear safety glasses and other appropriate protective equipment when operating this product Electric Shock e This product must be connected to a grounded power outlet for safe functioning e Use only the power cord supplied
10. revent fluid spill over from rapid turnover and decoupling of stir bar 6 The Labnet hot plate has an electronic feedback control which will accurately maintain tem perature Labnet hot plates stirrers and stirrer hot plates are designed to provide safe functioning under the following conditions e Indoor use e Altitude up to 2000 meters 6 500 feet e Ambient temperatures of 0 C to 40 C e Product should be placed on a flat surface at least 30 5 cm 12 from walls 122 cm 48 from ceilings and 30 5 cm 12 from other hot plates if using multiple units e Maximum relative humidity of 85 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C e Pollution Degree 2 Any foreign matter that may accumulate on or within the product during normal use is not electrically conductive e Installation Category Il Product is designed for connection to an electrical branch circuit inside a building with main supply voltage fluctuations not exceeding 10 of the nominal voltage Product Controls and Indicators Front side Ceramic Coated Top Plate Temperature On Indicator Lamp Hot Top Indicator Lamp Speed On Indicator Lamp ACOCUPLATE es ANALOG HOTPLATE STIRF Power Switch Labnet Stir Control Knob Heat Control Knob Rear Side Support Rod Power Inlet with Holder fuse holder Instructions for Use
11. urchase it Institution What feature s would you change to improve the performance of this product l Address Labnet 31 Mayfield Avenue Edison NJ 08837 Labnet International Inc p 732 417 0700 f 732 417 1750 LIT M03001 October 2014 Version 1 0 11 Labnet International Inc ORs
12. with the product e The power cord is the device available for full disconnect from mains input e Position the product for use so that the power cord can be easily disconnected without having to move the product e Disconnect the power cord before moving or cleaning the unit Product Damage e Keep the product dry and clean e Do not immerse the product for cleaning e Do not heat or stir volatile or flammable materials e The ceramic coated top surface may break if impacted e The maximum sample volume stirring capacity is 5L e These units are not explosion or spark proof e Do not operate this product near volatile or flammable materials e Do not use this product with a metal vessel Operating Conditions Your Labnet hot plate stirrer or stirring hot plate is a general purpose heating and or stirring plate designed for laboratory procedures requiring precise control of temperature and or stirring speed Your hot plate stirrer or stirring hot plate has the following properties 1 Ceramic coated top plate Ceramic coated top plate is corrosion proof temperature resistant and resists aggressive fluids 2 Coated in a pure white plate allows for easy observation of sample color change during use 3 The top plate allows for quick thermal conduction and uniform surface temperature 4 This device uses an electronic Analog temperature controller to control temperature 5 The Labnet Hot Plate Stirrers were designed to start and stop smoothly to p

Download Pdf Manuals

image

Related Search

Related Contents

Dicota Hard cover  manual  1.取扱説明書 - 日立の家電品  USER MANUAL  GSM Alarm User Manual  Samsung SR8845 manual de utilizador  ISTE Classroom Observation Tool: ICOT v3.1 User Manual  Spirit Esprit ET4 User's Manual  Download: TruDO Sensor Troubleshooting Guide  Rentrée 2015 – 2016 dans les collèges de Meurthe-et  