1. sudden changes in Infra Red temperature e g Body Heat A transformer which converts the 240 VAC Mains Power to 16 VAC to run the Security System When a section is Armed and has not been activated A section may be programmed to be silent i e does not trigger the siren or strobe in alarm A timer used to limit the running time of the siren page 3 Keypad Section Lights Program Light There are up to 48 section lights on the keypad When the Area is in the OFF mode the sections for that area are not armed except for 24 hour sections and the Section Lights indicate the condition of the sensor When the Section Light is ON the sensor is activated e g door contact detecting door open or motion detector sensing movement When the Section Light is OFF the sensor is not activated When the Area is in the ON mode the sections for that area are armed If the section light is Flashing the sensor is activated and triggers the siren and strobe light unless programmed to be silent This alarm is transmitted to the Central Station When the light is out the section is not activated When the Area has been Armed an exit timer starts and holds the sections that have been programmed for Exit delay disarmed This allows the user to exit the premises without activating the alarm When the Area is armed and the Exit timer has finished Entry into the premises can be made via a section that has Entry delay
2. Manufacturer nor any other person is authorised to modify this warranty in any respect This warranty gives you specific legal rights and you may also have other rights which vary from state to state page 13 Section List 14 Section List 15 Important Information Central Station Phone Security Company Phone Control Panel Type Date Installed Installed by Proudly Designed and Manufactured In Australia by A m MCM Electronics Pty Ltd Unit 3 10 Abel St Penrith NSW 2750 Australia acn 003 036 806 Tel 02 4721 8067 Fax 02 4721 8572 page 16
3. Statement MCM Electronics Pty Ltd the Manufacturer warrants its manufactured equipment to be free from defects in material and workmanship for a period of twelve 12 months from the date of manufacture as indicated by the date stamp and or serial number on the product Detective units returned by the buyer at his own expense during this period will be repaired or replaced at the option of the Manufacturer with an equivalent piece of re manufactured and tested equipment The repaired or replaced equipment is then warranted for the balance of the initial warranty period for thirty 30 days whichever is longer The repair or replacement will be without charge provided that the equipment has not been subjected to electrical or physical misuse or to unauthorised repair or modification The foregoing warranty is in lieu of all other warranties express or implied including but not limited to merchantability or fitness for a particular purpose The purchaser s exclusive remedy with respect to any and all losses or damages resulting from any cause whatsoever shall be repair or replacement as specified above The Manufacturer shall in no event be liable for any consequential or incidental damages however occasioned whether by negligence or otherwise No suit or action shall be brought against the Manufacturer more than one 1 year after the accrual of the cause of action therefore No agent employee or representative of the
4. has been selected for isolation will be ignored If disarming an area then only 24 hour sections may be isolated When entering section numbers a two digit number must be used Only valid section numbers may be entered Non 24 hour sections are automatically de isolated when the Area is turned OFF Key Sequence peration Example shows a User Code 1 2 3 4 2 3 4 isolate being used to enter Isolation mode 4 Sections 4 and 7 are being Isolated the Area the User Code is allocated On When desired sections are isolated the Area to ON mode page 8 Changing User Codes Functions 01 90 Notes l 2 Default User Code 01 1111 with Areas 1 2 3 4 5 6 7 8 User codes are 4 digits long and can be allocated to control any combination of areas User codes are used to change the status of panel isolate sections or acknowledge alarms User codes cannot be the same or within one count of another User code or be the first 4 digits of the 6 digit Master Code or Technician Code To change User codes all areas must be in the OFF mode Area 7 is not a physical area but is used to limit access to panel test functions and print requests Enable area 7 for the user code that will be used for test functions and print requests Area 8 is not a physical area but is used to inhibit a user s abitlity to isolate a section To delete a user code enter the isolate key as the new code KeySequence peration 1 8
5. 5 T 2 On Example shows Master code 218572 used to enter program mode 1 Select a User code 01 90 Example shows 01 2 3 4 On Enter and Store new user code 123 4 1 partial Select User code 01 area allocation mode 4 0 5 Select area 4 and 5 then store Finish selection and exit area allocation mode 2 isolate On Select and delete user 02 Off Exit program mode page 9 Changing the Master Code Function 00 Notes l 2 3 Off Master code default is 218572 Master code is 6 digits long The Master code is only used to program the user codes lt cannot change the status of the system All Areas must be in the OFF mode to enter the master code KeySequence Operation 1 8 5 2 On Enter existing Master code 218572 used to enter program mode 0 Select function OO 4 6 8 1 2 On Enter new master code 246812 Exit program mode with the OFF key page 10 Test Functions Notes l Test your system regularly and this will keep you familiar with the system and confident in the systems operation 2 Maximum testing time is 10 minutes 3 All Areas must be in the OFF mode before entering test mode 4 Test modes described below Test 1 Walk test Beeper and section light operates This test enables the user to walk around and activate sensors and check correct operation of sensors Test 2 Siren test Siren sounds for seconds Test Strobe test Strobe operates unitl
6. The Icon Series User Guide CDV25 Version 1 0 Contents Terms you need to Know Keypad Indicators Keypad Keys User Functions with Partitioned Systems Arming an Area with a User code Disarming an Area with a User Code Isolating a Section User Code Programming Master Code Programming Test Functions Clock Functions Warranty Section List Important Information page 2 N OD 10 11 12 13 14 16 Alarm Area Area Area On Arming Central Station Door Contact Entry Timer Exit Timer Isolate Passive Infra Red Plug Pack Sealed Silent Section Siren Timer The state of a security system when an armed sensor has been activated A group of sections that may be independantly armed and disarmed A security system may have several areas All sections that are programmed for that Area are Disarmed except sections programmed for 24 Hour mode All sections that are programmed for that Area are Armed except a section which is isolated place a section or panel ready to accept alarm A place where alarms are received and appropriateaction taken in response to the alarm A sensor which detects the opening of a door A timer that is used to delay the activation of an alarm A timer used to delay the arming of an Exit Entry section To inhibit or bypass one or more sections from arming A sensor which detects movement by sensing
7. This will start the Entry delay If the Area is disarmed before the Entry Delay Timer expires there will be no alarm When fitted this Light will be ON when a Master code is entered and the user codes are being viewed or changed Program Light is also On when user code is in Isolate or Test modes page 4 cont d Power Light Area This light is normally ON This indicates that the Plug Pack power and backup battery are normal When the mains has failed the power light will single flash When the battery is low in voltage the power light will double flash Fast flashing while in Program mode ON when the Area is armed Single flash when the Area is armed and the Exit timer is running Double flash when a section in Alarm for that Area or the Entry timer is running OFF indicates Area is not Armed 0 9 Keys Test Key Isolate Key Partial Key O ff Key On Key Used to enter numeric Codes or select Functions Used when a valid User Code has been entered to enter Test mode Used when a valid User Code has been entered to Isolate a section while Arming the System Used when a valid User Code has been entered to select which Area is to be armed or disarmed Used when a valid User Code has been entered to Disarm all areas assigned to that user code Used when a valid User Code has been entered to Arm the Area or Areas assigned to that user code page 5 Arming Areas w
8. ith User Code Notes User codes may be allocated to control any combination of Areas and can only Arm and Disarm these preprogrammed Areas An Area will not Arm unless all section lights in the Area are out or the section is Isolated If a Section is already Isolated before Arming it will remain Isolated until the Area is Disarmed Power light should be ON and not flashing Unless Partial or Isolate keys have been pressed Any section may be programmed to have Exit Time The Exit Timer starts as soon as the Area is Armed and the Area light starts flashing The beeper beeps while the Exit timer is running Exit only via programmed Exit Entry sections in the area that is being Armed If the Exit Entry sections are not sealed when the exit timer expires then the siren will give 2 second warning and the entry timer is started If the area is not turned OFF before the entry time expires a full siren strobe and alarm transmission to the Central Station will occur When a user code is entered all the Areas that the code is permitted to control are selected for arming To limit which areas are selected the Part or Partial key may be pressed Specific Areas may then be selected for Arming When Partial Area arming is selected the area indicators will be ON if the Area is Armed OFF if the Area is not Armed or flashing if it is selected for partial Area Arming Key Sequence Operation Example shows a User C
9. next key press Test 4 Test all lights and beeper operates until the next key is pressed used tocheck operation of lights and beeper Test 5 Recall Last Alarm last alarm flashes until next key press Test 71 Print a report of the last 150 events in the Event log Test 70 Print a report of the all the events in the Event log 1000 Test mode is exited Abort print report by pressing any key Test 9 Dialler Only Sends a Test Message to the Central station Test mode is exited KeySequence Operation 1 2 3 4 Test Example shows a User Code 1 2 3 4 being used to enter test mode 1 Test 1 started walk test 2 Test 2 started siren test Off Exit test mode page 11 Changing Time and Date Functions 97 and 98 Notes 1 All areas must be in Off mode 2 The Time setting is changed with Function 97 and is 4 digits long The format is HH MM where HH is hours 00 23 MM is minutes 00 59 3 The Date setting is changed with Function 98 and is 6 digits long The format of DDMMYY where DD is the day 01 31 MM is the month 01 12 YY is the year 00 99 Key Sequence peration Example shows Master 2 1 8 5 7 2 code 218572 used to enter program mode 9 T Select Function 97 Time set 1 9 3 0 Enter new time Example shows 7 30 pm 9 8 Select Function 98 Date set 0 4 1 0 9 Enter new date Example shows 4 October 1997 Off Exit program mode with the OFF key page 12 Warranty
10. ode 1 2 3 4 2 3 4 On being used to arm all it s Areas 2 3 4 partial Example shows a User Code 1 2 3 4 selecting partial to arm areas 4 and 5 5 On page 6 Disarming Areas with a User Code Notes l User codes can be allocated to control any combination of Areas and can only Arm and Disarm these preprogrammed Areas This key sequence also acknowledges or silences the siren strobe if an alarm is activated When a user code is entered all the areas that the code is permitted to control are selected for disarming To limit which areas are selected the partial key may be pressed then specific Areas may be selected for Disarming All non 24 hour sections that are isolated will De lsolated when area is disarmed Key Sequence O peration Example shows a User Code 1 2 3 4 2 3 4 Off being used to dis arm all its Areas Isolated Sections will Slow Flash 2 3 4 partial Example shows a User Code 1 2 3 4 selecting partial mode to dis arm areas 4 and 5 5 Off Isolating a Section Notes l When a valid user code has been entered and the isolate key has been pressed all isolated sections will be Slow Flashing Any section may be Selected or De Selected and only sections that are Slow Flashing will be isolated when the Area is On An Area may be armed or disarmed with sections Isolated Only sections that are allocated to the Area being armed may be isolated Any other section that

Download Pdf Manuals

image

Related Search

Related Contents

resumen de características del producto 1  PL-200AV-PEW USER MANUAL  EOLIENNE S700 Régulateur de Charge Externe Manuel Francais V.6  User Manual  Descripción del concentrador de oxígeno Inogen One  BILLY GOAT AERIFIZIERER Benutzerhandbuch  取扱説明書 - ケイアイシー  iTunes U Guidelines  3D GeoModeller Tutorial Case Study J  PLASMA TV  