1. STEP 3 channels nf YU STEP 4 successive channels STEP 5 Press 6 to set the first channel of a series of channels Press then Press 1 0 to set the last channel of a series of Press AT and Press 8 0 to set the same dimming level for the Press ENTER to confirm and then the led display the next channel Follow the steps as above to set the dimming level for following channels 10 Lite Puter CP 3B EUM E 3 How to display the dimming level of the channel Eg To check the dimming level of the 5 channel STEP 1 Press CH to channel mode STEP 2 Press 5 e STEP 3 Press AT to display the dimming level of 5 channel lt gt AH 4 How to modify the dimming level of channels Eg the user wants to modify 5 channel demming level from 50 to 80 STEP 1 Refer to section 4 3 led displays the original dimming level STEP 2 Press 8 0 to set the new dimming level UU UU STEP 3 Press ENTER to confirm The old dimming level are substituted by the new one 11 Lite Puter CP 3B EUM E 4 2 Scene 100 scenes from scene 00 to scene 99 can be memorized in CP 3B which is the best choice of public area Eg
2. DP 11 DMX Patch Setting Panel This unit is for DMX soft patch you can change the dimming channel without change the wiring DX 1220 DMX Plug In Dimmer Pack Each module can be removed easily 20A per channel can be set dimming or switching for different kind of loads You cannot set scene by CP 2B but CP 3B or use other DMX console If you save the data in DP 6 and then take away CP 3B you can still call out the data saved in DP 6 by CP 2B 3 Lite Puter CP 3B EUM E Chapter 2 Installation How to connect with DP 6B amp CP 3B CP 2B STEP 1 Connect CP 2B CP 3B and DP 6B by a cable from 6 pin phone jack on CP 3B CP 2B back panel to the 9 pin d type plug amp socket on cable side are reversed please check pin indictor on the connector SOCKET PLUG E HH CP 2B CP 3B PIN 1 DC 12V PIN 2 DATA PIN 3 PIN 4 GND PIN 5 DATA PIN 6 NC PIN 1 PIN 2 GND PIN3 DATA 543 2 1 PIN 4 DATA ee0e00 A PIN 5 PIN 6 DC12V 7 0 00 PIN 7 PIN9 NC 9 8 7 6 Note The order of 9 pin plug amp sockets are opposits STEP 2 Connecting DMX OUT 5 pin XLR connector on DP 6B panel to DMX IN 5 pin XLR connectors on DMX dimming pack Such as DX 1220 If you have DP 11 connect DP 6 to DP 11 than to the dimming pack TIN PIN 1 G
3. PIN 1 G T e PIN 2 DATA PIN 2 DATA J PIN 3 DATA PIN 3 DATA DMX OUT FAAN a PIN 4 NC PIN 4 NC QI QT f PIN 5 NC PIN 5 NC PIN 1 G l en PIN 1 G PIN 2 DATA Else a in A AAN DMX IN a i b Yer BNA NG PIN diagram of DP 6B DP 11 PIN diagram of DX 1220 4 Lite Puter CP 3B EUM E Sn CP 2B P 3E NI Front Panel p Remark The instruction of using twisted pairs WHITE RED GREEN BLACK SILVER Al Myler shielded twied pair 24AWG CAUTION 1 Always use the same twisted pair for DATA and DATA 2 In the illustration the red wire and the white one are a pair the green and black are the other Color is not the point but do use the same twisted pair 3 Use another twisted pair for DC12V power input 4 The ground silver must be connected to the chassis of DP 6B 5 Lite Puter CP 3B EUM E Chapter 3 The functions of CP 2B CP 3B e One touch to call out any of 7 scenes S1 S6 amp OFF that were preset e 256 steps of dimming resolutions e Memories are protected by backup battery of DP 6B and the last scene will be recalled automatically after ther recover o
4. The lobby in big hotel CP 3B has timer functions which can make all the lighting effects set in advance and executive on schdule automaually 1 How to save the dimming level of each channel in a scene eg save the dimming level in scene 1 1 30 2 100 3 50 STEP 1 Set the dimming level of each channel you need Please refer to 4 1 STEP 2 Press SC to the SCENE model the led displays It means that there is no scene executed STEP 3 Press 1 to save the no of scene STEP 4 Press FUN ENTER at the same time to confirm Lite Puter CP 3B EUM E 12 2 How to set timer function of scene Suggestion The scenes used everyday of cyclic should be stored into timer function Eg Scene 1 timmer setting at 6 30 STEP 1 Press FUNC 3 at the same time to the checking mode the led will display the time of the scene memoried previously If there is no data saved and it will display STEP 2 Press AT the cursor will glimmer and stay at left 00 STEP 3 STEP 4 Press A Jor Y tillthe led displays 6 Press ENTER the vernier will glimmer and stay at right 00 STEP 5 Press A or V till the led displays 30 STEP 6 Press ENTER
5. 39 40 Fd 41 Fd 42 Fd 43 Fd 44 Fd 45 Fd 46 Fd 47 Fd 48 Fd 49 Fd 50 41 42 43 44 45 46 47 48 49 50 Fd 51 Fd 52 Fd 53 Fd 54 Fd 55 Fd 56 Fd 57 Fd 58 Fd 59 Fd 60 51 52 53 54 55 56 57 58 59 60 Fd 61 Fd 62 Fd 63 Fd 64 Fd 65 Fd 66 Fd 67 Fd 68 Fd 69 Fd 70 61 62 63 64 65 66 67 68 69 70 Fd 71 Fd 72 Fd 73 Fd 74 Fd 75 Fd 76 Fd 77 Fd 78 Fd 79 Fd 80 71 72 73 74 75 76 77 78 79 80 Fd 81 Fd 82 Fd 83 Fd 84 Fd 85 Fd 86 Fd 87 Fd 88 Fd 89 Fd 90 81 82 83 84 85 86 87 88 89 90 16 Lite Puter CP 3B EUM E 8 How to call out scene 0 scene 9 by special key In the time mode no 0 no 9 on the panel can be defined the special key of scene 0 scene 9 Eg Call out the scene 6 Condition 1 In the TIME mode call out any scene from scene 0 9 to fade in instead of the current scene STEP 1 Press 6 to call out the scene 6 the scene 6 will fade in and the current scene will fade out Condition 2 In the TIME mode call out any scene from scene 0 9 instead of the current scene immediately STEP 1 Press 6 two times within 1 sec to cancel the fader function of the scene 9 How to call out the scene 10 scene 99 Eg call out the scene 28 immediately Condition In the TIME mode call out any scene from scene 10 99 instead o
6. Eg in section 5 4 the user wants to cancel setting time 21 30 STEP 1 Press FUNC 3 at the same time to check mode And the led displays STEP 2 Press A till led displays STEP 3 Press FUNC at the same time to cancel the time setting without changing the original data 6 How to set fader function The range of fader time 0 min 90 min STEP 1 Press FUNC 5 at the same time to fader mode STEP 2 Press A Increase fading time or W decrease fading time to meet yo ur needs STEP 3 Press FUNC ENTER at the same time to confirm 15 Lite Puter CP 3B EUM E 7 Corresponding list of fader time Fd 0 Fd 1 Fd 2 Fd 3 Fd 4 Fd 5 Fd 6 Fd 7 Fd 8 Fd 9 0 1sec 6 sec 12 sec 18 sec 24 sec 30 sec 36 sec 42 sec 48 sec 54 sec Fd 01 Fd 02 Fd 03 Fd 04 Fd 05 Fd 06 Fd 07 Fd 08 Fd 09 Fd 10 1min 2min 3min 4min 5min 6min 7min 8min 9min 10min Fd 11 Fd 12 Fd 13 Fd 14 Fd 15 Fd 16 Fd 17 Fd 18 Fd 19 Fd 20 11 12 13 14 15 16 17 18 19 20 Fd 21 Fd 22 Fd 23 Fd 24 Fd 25 Fd 26 Fd 27 Fd 28 Fd 29 Fd 30 21 22 23 24 25 26 27 28 29 30 Fd 31 Fd 32 Fd 33 Fd 34 Fd 35 Fd 36 Fd 37 Fd 38 Fd 39 Fd 40 31 32 33 34 35 36 37 38
7. at the same time and save the modified dimming level in the 2 SCENE P S Step 2 and step 3 can be skipped if the data need not be saved in the 2 scene 20 Lite Puter CP 3B EUM E TIME To display the current time 1 How to set hours and minutes in the led Eg The user wants to change the current time 00 00 to 16 30 STEP 1 Press FUNC 1 at the same time the cursor will glimmer and stay at left 00 N hour minute STEP 2 Press A or V till the led diaplays 16 STEP 3 Press ENTER the cursor will glimmer and stay at right 00 N E CA O DD pont STEP 4 Press A Jor V till the led displays 30 LAS 00 on STEP 5 Press TIME and the led will display the modified time EM 0 Ao CT 21 Lite Puter CP 3B EUM E 4 5 Special functions for emergency situations 1 How to turn off all the lights immediately In TIME mode press OFF to current scene and turn off all the lights of the scene The function will last till the scene next scene on schudule is executed EG To turn off the lights for a birthday party 2 How to increase all the dimming level of the current scene In TIME mode press A to adjust the brightness as desired The adjustment made by A will not be stored in to the current scene 3 How to decrease all
8. nag a in un CRT o Pie C4 ses 7 EL 5608 se ko D 1 UN cit el dh DP 6B DMX DECODER DP 11 DMX PATCH PANEL IE gh one Hat hen Si tf a S aa ai ad U olololojofofofjololok o Lite Puter s Architechtural amp Environmental Lighting Control System CP 2B DMX Control Panel It is easy to call out Scene1 Scene6 OFF to meet your needs each button has programmed different dimming levels which is called scene You can also control the same area by connecting several pieces of CP 2B multi control points or control independently when one area is separated into small sections 8 sections max for 1 DP 6 16 sections max for 2 DP 6 etc CP 3B DMX Control Panel You can set call out the dimming level and the time of changing scene in each area You can also control the same area by connecting several pieces of CP 3B multi control points or control independently when one area is separated into small sections 8 sections max for 1 DP 6 16 sections max for 2 DP 6 etc 2 Lite Puter CP 3B EUM E DP 6 DMX Decoder It controls 256 channels stores 100 scenes It has the timer functions for automatically executive scenes according to the schedule that has been set
9. press FUNC LCD displays EDIT AUTO CLOCK CONTROL TABLE STEP 2 press ETR to check the current scene STEP 3 press FUNC to exit NOTE 1 Timer function of scene is set by CP 3B ref sec 4 2 2 Press A to display the next set time of scene 3 Press Y to display the previous set time of scene 29 Lite Puter CP 3B EUM E 3 Setting 8 zones STEP 1 press FUNC LCD displays SYSTEM SETTING ZONE amp CH MAPPING STEP 2 press ETR to display the controlled channels in Zone 1 ZONE amp CH TABLE 7 Ch001 Ch032 Zone 1 includes ch 1 ch 32 STEP 3 press ETR Zone 1 glimmers ZONE amp CH TABLE ZI Ch001 Ch032 PS press A orf Y to display the channels in next previous zone 30 Lite Puter CP 3B EUM E STEP 4 press ETR and LCD displays ZONE amp CH TABLE Are you surel STEP 5f press FUNC O ETR at the same time and LCD displays ZONE amp CH TABLE 71 Ch001 Ch032 simmer Ch032 will be STEP 6 press A orf WL till 42 P S If users want to revise channels Ch01 Ch42 in Zone 1 STEP 7 press ETR and LCD diaplays ZONE amp CH TABLE 72 Ch043 Ch064 Glimmer Ch064 will be revised STEP 8 press A o
10. the LED will display the no of current scene STEP 7 Press O 1 LT 00 A N UV STEP 8 Press FUNC ENTER at the same time to confirm and timer setting at 6 30 for scene 1 Lite Puter CP 3B EUM E 13 3 How to execute or cancel timer function of scene Execute Press FUNC TIME at the same time the glimmering led means the system is in the timer mode Cancel Press FUNC TIME at the same time again the led stops glimmering and the function will be canceled 4 How to check the timer function of scene Eg in a resturant the previous setting time Scene 1 during breakfast startat 6 30 Scene 2 during lunch startat 11 30 Scene 3 during dinner startat 18 00 Scene 4 In the evening startat 21 30 Please refer 5 2 to follow the steps The resturant is in the scene 2 during luch time STEP 1 Press FUNC 3 at the same time to the timer mode of scene LED will display scene 1 at 6 30 STEP 2 Press A to display the next setting time ED W f y A i SI y ET a A lo E3 STEP 3 Press 7 to display the previous setting time EM 000 NR CJ F9 000 1 CI 14 Lite Puter CP 3B EUM E 5 How to cancel timer function of scene
11. 9 How to call out the scene 10 scene 99 17 4 3 Blind 1 How to modify and set any scenes without influencing the current scene meeeeee 18 2 How to modify the dimming level of all channels in the current scene lt mmm 20 4 4 Timer How to set hours and minutes in the led 21 4 5 Special functions for emergency situations 1 How to turn off all the lights immediately 22 2 How to increase all the dimming level of the current scene 22 3 How to decrease all the dimming level of the current scene 22 4 How to lock and unlock the function key 22 Chapter 5 DP 6B DP 6S 5 1 Feature amp specifications 23 5 2 Installations ns a ns 25 5 3 Operation oara na Pan er ue ia 27 Chapter 6 DP 11 6 1 Feature amp specifications 0000000 cece 33 6 2 Operation nn ai gta eul ei eta 34 1 Lite Puter CP 3B EUM E Chapter 1 Lite Puter Environmental Lighting Control System Lite Puter Environmental Lighting Control System use degital panel CP 2B CP 3B to connect with DMX decorder DP 6 and DX 1220 the dimmer pack This system can be used in environmental lighting control system to control the lighting atmosphere in each room or public area such as hotel fair conference hall department store and entertainment center etc CONTROL PANEL DX 1220 G IN DIMMER PACK ES RG EG ELEC koe NQE Ca EA ETA EI E z Ng frao nga ra ma
12. CP 3B EUM E Press AT to check the current dimming level STEP 8 STEP 9 Press FUNC 5 at the same time to fader mode STEP 9 Press Y J till the led display 20 STEP 10 Press FUNC 3 at the same time to timer mode LED will display Please refer to section 5 4 scene 1 at 6 30 Re i Press AT the vernier will glimmer and stay at left 06 STEP 11 STEP 12 Press A till the led display 18 UY nn ED 000 LL Press SC and press 0 2 to scene 2 STEP 13 STEP 14 Press FUNC ENTER at the same time to confirm and save the 19 Lite Puter CP 3B EUM E modified data in the second scene P S The example of Scene 2 you saw is for increasing a scene on to the schedule the Scene 2 will be executived on 11 30 and 18 30 If you want Scene 2 be executived only on 18 30 press FUNC 3 find out the schedule of 11 30 then press FUNC to cancel 2 How to modify the dimming level of all channels in the current scene Eg in current scene 2 STEP 1 Press to increse or decrease dimming level or press Y to decrease dimming level STEP 2 Press SC to scene mode and then press 0 2 STEP 3 Press FUNC ENTER
13. ING Fm G6 00 66 68 Signal monitor Display the version Lite Puter DP 6S Lite Puter DP 6S OMX INTERFACE y OMX INTERFACE _ y OMX INTERFACE STGNAL MONITOR DP 6B U2 08 97 ENU_HOLD CC LITE FUTER 27 Lite Puter CP 3B EUM E Display the current time LCD displays the current time as soon as DP 6 is power on Eg 99 JUN 16 WED 12 08 08 i 1 1 How to adjust the current time eg change the above time to TUE MAR 16 2000 at 12 08 08 STEP 1 press ETR under the current time mode and LCD displays SYSTEM TIME Are you sure STEP 2 press FUNC ETR at the same time and glimmer 99 will be 99 JUN 16 WED 120 08 08 revised STEP 3 press A 1 time and LCD displays 00 which means 2000 year 00 JUN 16 WED 12 08 08 STEP 4 press ETR to confirm and glimmer JUN will be revised OO JUN 16 WED 12 08 08 STEP 5 press Y 3 times and LCD displays MAR 00 MAR 16 WED 12 08 08 28 Lite Puter CP 3B EUM E STEP 6 press ENTER to confirm and glimmer WED will be revised 00 MAR 16 WED 12 08 08 STEP 7 press Y 1time and LCD displays TUE 00 MAR 16 TUE 12 08 08 STEP 8 press FUNC to confirm the setting time 2 Display the current scene STEP 1
14. Lite Puter ISO 9001 CERTIFIED www liteputer com tw Architectural amp Environmental Lighting Control System User manual SSS ru Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com tw LITE PUTER CP 3B EUM E Index Chapter 1 Lite Puter Environmental Lighting Control System 2 Chapter 2 Installation EE Dal nn en see ba seal le MU de ved ad aaa dd ate pui nr S 4 Chapter 3 The functions of CP 2B CP 3B Sa OP HQ BF ix ccc tes vate ta aa dna aaa ao ap E data aaa eats 6 3 2 CPH3B es vss icccincivataad dea tin cati a aia caii acc i at a 7 Chapter 4 The operation of CP 3B 4 1 Channel 1 How to set the dimming level of each channel 9 2 How to set the dimming level of a series of channels 10 3 How to display the dimming level of the channel 11 4 How to modify the dimming level of channels 11 4 2 Scene 1 How to save the dimming level of each channel in a scene 12 2 How to set timer function of scene 13 3 How to execute or cancel timer function of scene 14 4 How to check the timer function of scene u e 14 5 How to cancel timer function of scene mmm nenea 15 6 How to set fader function secirerossorimeiosaiin nna 15 7 Corresponding list of fader time 16 8 How to call out scene 0 scene 9 by special key 17
15. ar light Signal transit distance 1km Power Supply AC90 240V DMX signal input RS485 or DMX512 1990 DMX signal output DMX512 1990 Transit speed 250K BITS Sec DMX signal connector XLR 5PIN 23 Lite Puter CP 3B EUM E m Dimension DP 6B 480 W x 88 H x 96 D mm r a ca DP 6S 115 W x 150 H x 65 D mm E GION sade Sesto sinus DP 6B 2 8Kg Lite Puter DP 6S GEE OMX INTERFACE _ DP 6S LO oO CTEITETIET T I LO Lite Puiter DP 6S LO MIX INTERFACE _ om DP 6S Dimensions ad oO O LO E P ici iis WP us TU FT in B EEE O m ur D Lo R ee EE la 95 a E 115 al 24 Lite Puter CP 3B EUM E 5 2 Installation 5 2 1 The installation of DP 6B Llte Puter i a DISPLA JUN MAIN AC POWER 100 240VA INPUT 17 GIL O CONTROL PANELS Oll Sort INT GN SL gt POW 40VAC INI FOR NCY TECTION Le E NS V DC PIN6 V 12VDC SHIELD GND 4 LCD 2 Function Key 3 Forth A 4 Back Yy 5 Confirmati
16. ene 1 2 3 Increase starting time of the scene in fader function 1 2 Decrease the fader time in fader mode 3 Decrease starting time of the scene in fader function 10 THROUGH in channel mode specify range of successive channel 11 ENTER Make confirmation 12 AT In channel mode display the dimming level of the selected channel 8 Lite Puter CP 3B EUM E Chapter 4 The operation of CP 3B 4 1 Channel 1 How to set the dimming level of each channel EG set the 5 channel dimming level at 50 STEP 1 Press CH to channel mode and the led dispalys STEP 2 Press 5 to choose the channel no STEP 3 Press AT then press 5 0 to set dimming level 50 STEP 4 Press ENTER to confirm and then the led will dispay next channel Follow the steps as above to set the dimming level for following channels P S The dimming level range from 00 99 FL 100 Press OFF The dimming level is 00 The led displays Press A The dimming level is FL FL means 100 The led displays 9 Lite Puter CP 3B EUM E 2 How to set the dimming level of a series of channels Eg set the 6 channel to 10 channel at 80 Press CH to channel mode The led displays STEP 1 U OU a
17. er CP 3B EUM E Chapter 6 DP 11 6 1 Feature amp specifications DP 11 is a channel patch by using software so DP 11 can be applied after the hardware channels are installed When the users want to change the channels positions they only have to change the Patch Address in DP 11 instead of changing the hardware diagram m Power AC 90 240V 50 60Hz m DMX signal input output DMX512 1990 m DMX signal connector XLR 5PIN m Dimension 70 W x 120 H x 50 D mm m Rack size 19 2U rack mountable m Weight 2 8Kg FRONT PANEL INTRODUCTION eth a a nea E ep O 1 2 3 4 5 6 T 1 LCD DISPLAYER 2 FUNCTION KEY 3 DECREASE CH NO 4 INCREASE CH NO 5 CONFIMATION KEY 6 DMX IN 5 PIN SOCKET FOR DMX IN 7 POWER 8 DMX OUT 5 PINSOCKET FOR DMX OUT 33 Lite Puter CP 3B EUM E 6 2 Operation A HOW TO PATCH ADDRESS Eg set the fifth channel of pack to be the first channel of console STEP 1 Press FUNC key and LCD veriner will stay at DIMO01 Lite Puter DP DIM 001 C 001 Console channel no Pack channel no STEP 2 Press W to adjust to DIM 005 Lite Puter DPg 11 DIM005 CH 005 STEP 3 Press FUNC and veriner will stay at CHOOS Lite Puter DPg 11 DIM 005 CH 005 STEP 4 P
18. f electric power failure 1 6 SCENE 1 SCENE 6 7 OFF 8 A INCREASE THE DIMMING LEVEL P S Uuder any circumstances press this key to increase the dimming level of current scene up to 100 without changing the memory and the memories of S1 S6 wouldn t be changed 9 v DECREASE THE DIMMIGN LEVEL P S Uuder any circumstances to press this function key can make lighting level of all channels gradually reduced until full off and the memories of S1 S6 wouldn t be changed 10 DISPLAY THE CURRENT SCENE 11 DISPIAY THE CURRENT TIME 12 DISPLAY THE CURRENT TIME 6 Lite Puter CP 3B EUM E 3 2 CP 3B e 100 scenes memories 256 control channels output e Set the time of fade in and fade out e Timer function Blind function to modify the data of any scenes without changing the output of the current scene e Keyboard lock unlock function e 256 steps of dimming resolutions Memories are protected by backup battery Z ON hi ce o mm 2 a d CH ne B LO Q Rese 7 9 9 9 Oa 3 4 5 6 L o 09 e _v 9 pt ES 9 9 e O OFF 0 ATS r ENTER s 4 O O On 17 D Se Operatio
19. f the current scene STEP 1 Press SC to scene mode STEP 2 Press 2 8 STEP 3 Press ENTER to show the fader scene 28 P S Press ENTER two times to cancel the fader function of the scene 28 Attention 1 The scene call out by manual will last utill the next scene set on schedule starts 2 The original data saved in memory will not be changed 17 Lite Puter CP 3B EUM E 4 3 Blind Blind function To check modify and set any scene without influencing the current scene 1 How to modify and set any scenes without influencing the current scene Eg In a resturant The user wants to modify the scene or the fading time without changing the current scene he can follow the steps Old data 5 dimming level is 80 new datal 5 dimming level is FL 100 Fader time Fd 30 about 30min Fader time Fd 20 about 20min Timer 11 30am gt Timer 18 30 STEP 1 Press FUNC SC at the same time and the led of SC will glimmer that means in the blind mode STEP 2 Press SC and LED displays the current SCENE 1 A a Ls H 1 STEP 3 Press 0 2 and then press ENTER to confirm that the scene 2 will be modified STEP 4 Press CH J nn UU STEP 5 Press 5 18 Lite Puter
20. n FUNC 1 means holding FUNC key and press no 1 key at the same time 7 Lite Puter CP 3B EUM E Displsy amp Key operation FUNCTION LED DISPLAY 1 In time mode display the current time 2 In channel model display the dimming level of the current channel 3 In scene mode display the current scene s number 4 Press FUNC 11 model for modifing current time 5 Press FUNC 3 modd display the start time given for the scene you set 6 Under FUNC 5 model display the fader time for selected scene TIME In time mode the led will display the current time SC 1 Getting into Scene mode press scene number then enter to load a scene 2 In scene model check the no of current scene OFF 1 In channel model the dimming level of channel is 0 2 Turnning off the current output 0 9 Digital Key FUN 1 FUNC 0 7 5 3 lock unlock the panel 2 FUNC 1 set the current time 3 FUNC 3 set the timmer clock 5 FUNC 5 set fader time for selected scene 6 FUNC ENTER make confirmation CH 1 2 3 4 FUNC cancel the timmer clock 5 6 1 1 Go to channel mode To check the dimming level of each channel 2 Increase the fader time in fader mode Increase the dimming level of the current scene 1 Decrease the dimming level of the current sc
21. on Key 6 Reset For Engineer 7 DMX OUTPUT 8 DMX IN 9 Power Switch 10 MAIN AC POWER 100 240VAC Please use GC emergency power 41 General power detective 12 Power detective select Please use AC power Down Don t use detective power Up Use general power detective and AC power is on 43 RS 232 9 PIN Connector with CP 2B CP 3B 25 Lite Puter CP 3B EUM E 5 2 1 The installation of DP 6S er DP 6S DMX INTERFACE _ 1 LCD 2 DMX Output 3 Confirmation Key 4 Back Y 5 Forth A 6 Function Key 7 DC 12V GND 8 DMX Output 9 DMX IN 10 JAC INPUT V N E 11 Connect with CP 2B CP 3B 26 Lite Puter CP 3B EUM E 5 3 Operation Press FUNC in series to display 6 functions n Display the current time 2 Display the current scene Lite Puter DP 6S Lite Puter DP 6S mu DMX INTERFACE 95 MAY 26 MON EDIT AUTO CLOCK 12 26 32 CONTROL TABLE Setting 8 zone 4 New function reserved Lite Puter DP 6S Lite Puter DP 6S OMX INTERFACE OMX INTERFACE SYSTEM SETTING DARK SCENE 88 ZUNEZ CH MAPP
22. r Y revise the channels you want STEP 9 repeat STEP 7 STEP 8 to check or revise channels patch in other zones STEP 10 press FUNC ETRT to save the data you set STEP 11 Press FUNC to exit NOTED Users revise the setting channels which must be in series If series channels are not accepted please use our DP 11 channel soft patch to fix the problem How to restore the beginning channel set in each zone DP 6 set the beginning channel in each zone as follows ZA Ch001 Ch032 22221 Ch033 Ch064 Z3 Ch065 Ch096 lt 8 Ch097 Ch128 ZS Ch129 Ch160 6 Ch161 Ch192 27771 Ch193 Ch224 88 Ch225 Ch256 31 Lite Puter CP 3B EUM E STEP 1 press FUNC and LCD displays SYSTEM SETTING ZONE amp CH MAPPING STEP 2 press ETR LCD displays ZONE amp CH TABLE ZI Ch001 Ch042 STEP 3 press A or W LCD displays ZONE amp CH TABLE Reset to default STEP 4 press ETRO LCD displays RESET ZONE amp CH Are You Surel STEP 5f press FUNC O ETR at the same time to restore the beginning channel 4 New functions reserved DARK SCENE 00 Fm OQ 00 OO 00 5 Signal monitor for engineer SIGNAL MONITOR ENV FADE 6 Display the current version DP 6B V2 00 97 C LITE PUTER 32 Lite Put
23. ress A to adjust to CH001 STEP 5 Press FUNC ETR to confirm and set data into memory B HOW TO RESTORE THE ORIGINAL PATCH STEP 1 Turn off the AC power STEP 2 Press FUNC key till AC power is turned on again STEP 3 Release FUNC key after LCD displays information and then PATCH ADDRESS is restored 34 Lite Puter CP 3B EUM E
24. the dimming level of the current scene In TIME mode press 7 to sdjust the brightness as desired The adjustment made by Y will not be stored in to the current scene 4 How to lock and unlock the function key Lock Press FUNC 0 7 5 3 atthe same time Unlock Press FUNC 0 7 5 3 atthe same time again 22 Lite Puter CP 3B EUM E Chapter 5 DP 6B DP 6S Lite Puter designs two types of shape for DP 6 DP 6B and 5 1 Feature amp Specifications Lite Puler oP ss DP 6S in order to suit to install in defferent systems ane west DX 1220 DX 302A DX F01 and PX 304 256 channel DMX signal output DMX transit in RS 422 mode the output is connected with DMX dimmer pack such as DX 1220 RS 485 signal acceptable for connecting with CP 2B CP 3B Can set for 8 separate zones suitable for room with partitions Can connect over 10pcs control panels CP 3B and work as independent control mode or master slave mode 100 scenes can be memorized each scene controls 256 dimming channels Automatic protection for the system when output short and will recover after the short LCD indicator display year month day week hour min sec Timer function the changing steps can be set up to 120 scenes by the minute Fade in Fade out time the time setting can be applied for individual scene 0 1 sec 90 min Function of detecting sol