GFK-2965, RSTi-EP Slice PROFINET Scanner

image

Contents

1. At least one current path lt 18 V Green Input current path supply voltage gt 18 V DC Red Input current path supply voltage lt 18 V DC Ee Red Internal fuse defective Green Output current path supply voltage gt 18 V DC Red Output current path supply voltage lt 18 V DC Se Red Internal fuse defective For public disclosure 4 RSTi EP Slice I O PROFINET Scanner GFK 2965 Field Wiring The connection frame has one connector and two 24 V DC wires can be connected to each connector along with two ground connections Those four connectors are used as shown in the following figure The Spring style technology allows either finely stranded or solid wire with crimped wire end ferrules or ultrasonically welded wires each with a maximum cross section of 1 5 mm 16 guage to be inserted easily through the opening in the clamping terminal without having to use tools To insert fine stranded wires without wire end ferrules the pusher must be pressed in with a screwdriver and released to latch the wire Connector Block Connector Specifications e conductor cross section 0 14 to 1 5 mm 26 16 guage e max ampacity 10 A e 4 pole The modules do not have a fused sensor activator power supply All cables to the connected sensors actuators must be fused corresponding to their conductor cross sections as per Standard DIN EN 60204 1 section 12 Refer to the RSTI EP Slice I O User Manual GFK 2958 for additional information
2. For technical assistance go to http support ge ip com For public disclosure RSTi EP Slice I O PROFINET Scanner 5 GFK 2965 Connection Diagrams XI ry Ti 1 o m 4 RD 3 q RD 6 el O 2 oto T 1 oO m 2 RD 3 Q RD amp 24VDCIN 24W DCIN GND IN A GND IN 24W DC OUT 24W DC OUT Door for Micro END OUT EPXPNS001 Connection Block Diagrams Internal from the control card System USB ay N e I I I I l A I 5 I A EE i E m 1 RJ45 gt I Uy I _ 1 l I RJ45 I I I I I l l i O i I I I O I l Q r i Q I i m 24 V 10 A Output I I l EPXPNSOO1 For public disclosure 6 RSTi EP Slice I O PROFINET Scanner GFK 2965 Installation in Hazardous Areas EQUIPMENT LABELED WITH REFERENCE TO CLASS GROUPS A B C amp D DIV 2 HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A B C DOR NON HAZARDOUS AREAS ONLY A WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 A WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS AREAS TURN OFF POWER BEFORE REPLACING OR WIRING MODULES AND A WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS ATEX Marking gt 13 G Ex NA IIC T4 Gc Ta 20 C to 60 C 4 F to 140 F Thermal Derating The power supply is restricted according to the t
3. GFK 2965 November 2015 PWR SF BF MT LINK 1 ACT 1 LINK 2 and ACT 2 LEDs Door for Micro USB Port PROFINET Scanner RSTI EP Slice I O PROFINET Scanner EPXPNSOO1 The EPXPNS001 PROFINET Scanner is a PROFINET I O device certified by the PROFINET user organization The network adapter is the head module for the RSTi EP system bus to which up to 64 active RSTI EP modules can be connected The PROFINET network adapter has two Ethernet ports and an integrated switch The PROFINET Scanner can be accessed with a system independent web server application via the USB service interface or the Ethernet Thus all information such as diagnostics status values and parameters can be read and all connected modules can be simulated or forced The station s main power supply is integrated in the PROFINET Scanner Power is supplied via two 4 pole connectors separated into the input and output current paths Caution the RSTi EP station is usually installed on a horizontally positioned DIN rail Installation on vertically positioned DIN rails is also possible However the heat dissipation is reduced such that the derating values change refer to the section Thermal Derating Modules should to be allowed to de energize for a minimum 10 seconds after power down prior to starting any maintenance activity The PROFINET Scanner cannot be hot swapped Refer to the RSTI EP Slice I O User Manual GFK 2958 for additional information Refer
4. Power Feed Modules for Output Current Path EP 7641 Power Module 1 Channel 24VDC Output Flow 10A Safe Feed input Modules EP 1901 1 Safe Feed Input 24 VDC EP 1902 2 Safe Feed Inputs 24 VDC Programmable Delay EP 1922 2 Safe Feed Inputs 24 VDC Potential Distribution Modules EP 711F Power Module 16 Channels 24VDC Potential Distribution 24 VDC from Input Current Path EP 751F Power Module 16 Channels 24VDC Potential Distribution 24 VDC from Output Current Path EP 7Q0F Power Module 16 Channels 24VDC Potential Distribution Functional Earth EP 710F Power Module 16 Channels 24VDC Potential Distribution OVDC from Input Current Path EP 750F Power Module 16 Channels 24VDC Potential Distribution OVDC from Output Current Path Release History Version EPXPNSOO1 01 00 Nov 2015 Initial Release For public disclosure 8 GFK 2965 Important Product Information for this Release Updates Initial Release Funcional Compatibility Initial Release Problems Resolved by this Release None Initial Release New Features and Enhancements None Initial Release Known Restrictions and Open Issues None Operational Notes None Product Documentation RSTI EP Slice I O Module User Manual GFK 2958 RSTI EP Slice I O Functional Safety Module User Manual GFK 2956 GE Intelligent Platforms 1 800 433 2682 1 454 978 5100 www ge ip com For public disclosure RSTi EP Slice I O PROFINET Scanner
5. emperature The following values apply for the horizontal and vertical positioning of the RSTI EP station Temperature dependent Values for the Power Supply Rrra Varco Network adapter power supply 60 C 140 F 2 x8 A 55 C 131 F 2x6A 55 C 131 F 2 x 10 A 50 C 122 F 2 x8 A Power feed module power supply 60 C 140 F 1x 10A 55 C 131 F 1x8A Refer to the RSTI EP Slice I O Module User Manual GFK 2958 for additional information Supported Modules and Power Supplies The following modules can be used with this release of the RSTI EP PROFINET Network Adaptor EP 12F4 Digital Input 4 Points Positive Logic 24VDC 2 3 or 4 Wire Time stamp Digital Output Modules EP 2214 Digital Output 4 Points Positive Logic 24VDC 0 5A 2 3 or 4 Wire EP 2614 Digital Output 4 Points Positive Logic 24VDC 2 0A 2 3 or 4 Wire EP 2634 Digital Output 4 Points Positive Negative Logic 24VDC 2 0A 2 3 or 4 Wire EP 2218 Digital Output 8 Points Positive Logic 24VDC 0 5A 2 Wire EP 225F Digital Input 16 Points Positive Logic 24VDC 0 5A 1 Wire Digital Relay Output Modules EP 2714 Digital Relay Output 4 Points Positive Logic 24 220 VDC VAC 6A 2 Wire EP 2814 Solid state Relay Output Module For public disclosure RSTi EP Slice I O PROFINET Scanner 7 GFK 2965 EP 3804 Analog Input 4 Channels TC 16 Bits with Diagnostics 2 3 or 4 Wire EP542 EP 7631 Power Module 1 Channel 24VDC Input Flow 10A
6. orage temperature 40 C to 85 C 40 F to 185 F Air humidity operation transport 5 to 95 noncondensing as per DIN EN 61131 2 Width 52 mm 2 05 in Height 120 mm 4 72 in Weight 220 g 7 76 oz Configuration V2 3 GSDML file is available on the Support website http support ge ip com for download and import into Proficy Machine Edition The GSDML supporting a firmware release is part of the firmware upgrade kit available on the Support website For public disclosure RSTi EP Slice I O PROFINET Scanner 3 GFK 2965 LEDs LED Status Indicators LED State Description PWR Power LED Green Supply voltage connected Red Configuration error or error in the PROFINET Scanner or error in a SF System fault module or there is a new diagnostic report Red flashing Station in Force mode Red No connection to the fieldbus Bus fault Red flashing Configuration error no connection to the control unit or error in the parameter set MT Maintenance Yellow Error on the system bus or fieldbus Required Green Connection established between port 1 of the PROFINET Scanner and LINK 1 Connection another field device ACT 1 Yellow flashing Data being exchanged on port 1 Green Connection established between port 2 of the PROFINET Scanner and LINK 2 Connection another field device ACT 2 Yellow flashing Data being exchanged on port 2 LED Indicators EPXPNSOO1 Power Green Supply voltage gt 18 V DC Supply Red
7. to the RSTI EP Power Supply Reference Guide a software utility available on PME V9 00 for detailed power feed requirements Module Features Supports up to 64 active RSTI EP modules Spring style technology for ease of wiring DIN rail mounted Double click installation for positive indication of correct installation Built in Web Server for diagnostic information and firmware update through Ethernet and micro USB port Supports Media Redundancy Protocol MRP Client mode operation Support for daisy chain line star or ring MRP technologies Two switched Ethernet ports 8 conductor RJ 45 shielded twisted pair 10 100 Mbps copper interfaces Fast start up lt 500 ms with a maximum of 10 modules 2015 General Electric Company All Rights Reserved Indicates a trademark of General Electric Company and or its subsidiaries All other trademarks are the property of their respective owners 2 RSTi EP Slice I O PROFINET Scanner GFK 2965 Ordering Information EPXPNSOO1 RSTI EP Slice I O PROFINET IRT Network Adapter Specifications a EPXPNS001 Connection Fieldbus protocol OE Number of modules Configuration interface ESE Data format Configurable selections 1ms 2ms 4ms 8ms 16ms Supports MRP Supply voltage for system and inputs Supply voltage for outputs Max feed in current for input modules Max feed in current for output modules E men Single wired fine wired Operating temperature St