USER`S MANUAL - The Tulip Group, India

image

Contents

1. display will change to QC MANAGEMENT QC Name QC LOT QC EXP QC Target QC Range QC Unit Choice oat TH T Turbodyne SC Selecting the appropriate QC level from the choice row will change display to QC MANAGEMENT QC result is existed overlap it or not YES NO Selecting Yes will overwrite the QC value tested earlier on the same day Selecting No will not store the new QC data Note Details of QC must be entered in QC management refer QC Management before testing QC Selecting the MEASURE key will change the display to be ready for the next test 19 4 4 DATA MANAGEMENT This function is used a QC MANAGEMENT b Record Review of Results history Selecting the DATA MANAGEMENT button will display rs DATA MANAGEMENT i ANAGEMENT RECORD REVIEW a T i TM a Turbodyne SGA Turbidimetry Mopholamotry a 4 4 1 QC MANAGEMENT for setting up QC parameters and reviewing QC data and to Plot Levey Jennings QC MANAGEMENT for setting QC parameters Clicking on QC MANAGEMENT will change the display to QC MANAGEMENT i 1 2 3 A 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 29 26 di 28 29 30 31 32 Please Input Test Mo CONFIRM There are 32 QC locations numbered from 1 to 32 e Naming the QC Click on the space beside a number a key pad will emerge to put the name of the QC The name of the QC must be the same as the TEST NAME in the Smart card for which QC test is to be done If the QC nam
2. include a Any responsibility for direct or indirect personal and or material damages caused by improper use or maintenance of the analyser b Damage caused by natural calamities such as fire earthquake etc c Parts that are inherently subject to deterioration d Damage caused by corrosion of electrical parts In case of defects due to misuse of the analyser any incidental expenses like travel and man hour service charges will be charged extra Technical Service Tulip is always accessible to the customers for any kind of information about installation use and maintenance etc While asking for service please refer to this manual and refer the printed Serial No present at the back panel of the analyser Only qualified technicians are entitled to service the analyser Tulip technical service is available for maintenance under a yearly maintenance contract or on specific demand Ordering spare parts Parts subject to deterioration or defectives which need to be replaced have to be ordered by giving the following details e Name and version of the analyser e Analyser serial No e Name and address of customer for delivering the ordered goods While replacing the parts the use of ORIGINAL SPARE PARTS guarantees the efficiency and a lasting analyser life Ordering Address Tulip Diagnostics P Ltd Gitanjali Tulip Block Dr A A Rego Bagh Alto Santa Cruz Bambolim Complex P O Goa 403 202 Tel 91 832 2458546 50 Fax
3. select the enter key on the key pad to save the date time Clicking the CONFIRM key will lead to SET UP menu page 4 1 3 PRINTER SETTINGS Selecting the Printer settings key will open up the following display PRINTER SETTINGS Print Results ON OFF Report Header SET UP MENU 1 Print results e Selecting ON provides the option to print results after each test e Selecting OFF turns the printer OFF 2 Report Header Used to print the Report Heading during printing of test results For Eg If TULIP LAB is used in the report header then TULIP LAB will appear in the heading of each test result refer fig To feed the Report Heading select on the report heading window and a key pad will emerge on the display Feed the desired report heading MAX 24 characters and click the enter key to save and return to the PRINTER SETTINGS menu Select the SET UP or lt to return to the SET UP menu page 4 1 4 OTHER SETTINGS Currently not in use 13 4 2 SYSTEM SELF CHECK Clicking the SYSTEM SELF CHECK following display appears een meee z SYSTEM SELF CHECK K Wavelength bSOnm AV innear Dark Paini Channel Set oe J Set Channel Se naput Fewer Supply Range Oa TAE Jet Temperature Range 36 5 C 3 5 T Set EXIT This is strictly for use by the Service Engineer only The user must only check the display value which must be as described below The channel 1 linear value range must be 22000 28000 The Channe
4. source 650 nm Laser LED 2 Silicon Detectors e Turbidimetry 180 e Nephelometry 135 Automatic mixing Temperature 37 C 1 C Measuring Chamber Measurement e Auto start with electronic pipette e Manual start Inbuilt_mixer e Online reaction curve Smart card Integrated chip card Lot specific assay calibration Electronic Pipette Auto start of testing time Optical System Data Transfer RS 232 Data storage 900 results 290mm L X 170 mm W X 110 mm H Weight E 2 INSTALLING TUBODYNE SC e 3levels Data Transfer O ooo 2 1 PREPARATION OF INSTALLATION SITE The Turbodyne SC analyser is provided in a single carton with accessories described below e Power cable with AC DC adaptor RS 232 cable Turbodyne SC Incubator Turbodyne SC Incubator Power Adaptor Turbodyne SC Electronic Pipette 20 200 ul Turbodyne SC variable Pipette 100 1000ul Turbodyne SC variable Pipette 5 50 Turbodyne SC Printer rolls 1 qty Note Please store the carton and packaging material in a safe place for future use 2 2 INSTALLATION The installation of Turbodyne SC analyser must be carried out by Trained service Personal Tulip s Service Engineer only Unpack Turbodyne SC analyser carefully from the packing carton and place it on the installation site The analyser must be installed in a dust free place free of vibrations and away from direct light The ambient temperature should be between 15 35 C without excess h
5. the Accuracy Precision and Convenience of immunoassay estimation to a higher level Turbodyne SC is a creative integration of dual technology optics conformed to the principles of Nephelometry amp Turbidimetry in a single channel The unique Optimix auto mixing technology without use of stirrer or magnetic beads of Turbodyne SC ensures UNIFORM mixing of reagents and samples to achieve optimum reactivity in immunochemical reactions Turbodyne SC estimates analytes using Pre calibrated assay specific SMART CARD with integrated chip technology eliminating the probability of programming and calibration errors occurring at the user end The battery backup feature of Turbodyne SC makes it an ideal analyser for on field testing Turbodyne SC is compatible with TURBODYNE range of reagents only 1 1 Measuring Principle Nephelometry Detector D Turbidimetry Transmitted Light at 180 Detector Turbodyne SC uses dual technology optics A light beam passes through the test cuvette with Ag Ab reactions and falls onto photodetectors placed at 180 and 135 In turbidimetric assays reduction in intensity of transmitted light measured at 180 corresponds to the concentration of test analyte In nephelometric assays increase in amount of scattered light measured at 135 corresponds to the concentration of test analyte 1 2 Technical Specifications TURBODYNE SC Technical Specifications Measuring Principle Nephelometry Turbidimetry Light
6. 2 Personal Setting 4 1 3 Printer Setting 4 1 4 Other Setting 4 2 System Self Check 4 3 Measure 4 3 1 Saving Patient Results 4 3 2 Saving QC Results 4 4 Data Management 4 4 1 QC Management 4 4 2 Review QC Data 4 4 3 Review Patient Data Installing Printer Paper Trouble Shooting Maintenance Page No O O COAOAOAN NOD OD O OO A NR ROD BROS RO RO RO BRO na a CO or wdow 0 amp co O BP BW WN a n O 1 Introduction Tulip has always believed in its vision of continuously providing better testing systems for better diagnostics and preventive health since its inception The increasing patient awareness along with demand for rapid laboratory test results by Clinicians for better patient management requires increase in efficiency without compromising quality of reports In addition the inadequate availability of skilled amp dedicated technicians has raised the desire for better technology with improved throughput that takes care of manual errors thereby improving the quality of reporting for important analytes such as HbA1c Microalbuminuria C reactive Protein etc Understanding the difficulties of handling complexities incubation time mixing of reagents and samples reading of reactions programming associated with immunochemistries led to the birth of TURBODYNE SC Tulip takes great pleasure in making laboratories SELF RELIANT in handling immunochemistries with TURBODYNE SC Turbodyne SC takes
7. 91 832 2458544 E mail sales tulipgroup com Website www tulipgroup com 2 SAFETY INSTRUCTIONS This manual provides various symbols to ensure that the product may be used in a proper and safe way to prevent the user and others from risk of injuries and damage to property The meanings of the symbols are mentioned below A Warning If this sign is ignored and the instrument is not used in correct way there is potentially hazard risk that could lead to serious injury or death of the operator or grave property damage A Caution If this sign is ignored and instrument is not used in a correct way there is potentially hazard risk that could lead to serious injury or death of the operator or grave property damage Caution with regard to diagnosis A Caution This product is used for screening of clinical specimens to aid laboratory diagnosis The Physician is requested to take clinical examination results and other test results into consideration before making clinical judgement based on analysis of the clinical specimens i INDEX Title Introduction 1 1 Measuring Principle 1 2 Technical Specifications Installing Turbodyne SC 2 1 Preparation Installation Site 2 2 Installation 2 3 Other precautions during usage Analyser Overview 3 1 Description of analyser parts 3 2 Analyser Operations 3 2 1 The Analyser Operations 3 2 2 Switching on the Analyser Operation of the Main Menu 4 1 Setup Menu 4 1 1 System Setting 4 1
8. Turbodyne SG Turbidimetry e Nephelometry USER S MANUAL Laup TULIP DIAGNOSTICS P LTD Gitanjali Tulip Block Dr Antonion De Rego Bagh Alto Santacruz Bambolim P O GOA Pin 403202 Phone 91 832 2458546 51 Fax 91 832 2458544 Email sales tulipgroup com web www tulipgroup com All rights reserved by Tulip Diagnostics P Ltd No part of this manual may be reproduced in any form or by any means whatsoever without prior permission from Tulip Diagnostics P Ltd Version 10 2015 1 0 Preface Thank you very much for patronizing Turbodyne SC Kindly read the user manual carefully before operating the analyser to avoid risk to users damage to instrument and other equipment Keep the user manual at a proper place for referring in future Tulip Diagnostics P Ltd Does not accept responsibility for damage arising from non adherence to instructions provided in the user manual Warranty Each unit of Turbodyne SC has been thoroughly tested before shipment has been packed carefully to prevent damage from shipping and handling The instrument is warranted against defects for a period of twelve months from delivery The warranty applies to all the mechanical and electrical parts It is valid only for proper installation use and maintenance in compliance with instructions given in this manual Tulip will at its discretion repair or replace parts which may be found defective in the warranty period The warranty does not
9. be clicked on addition of R2 reagent to initiate the reading without using the Electronic Pipette On addition of R2 the display will change to STANDARD MODE 1 RI ul za amp ul Re ul Place Cuvette in the Cuvette Holder amp close the lid a AUTO MONG AE g 1 et TESTING The analyser will monitor the reaction On completion of the test following display will appear 17 STANDARD MODE Ol RI ul OC SUL R2 d SEND Testing Finished UNIT SAVE to sove result SAVE and to continue testing another sample PRINT EXIT MEASURE The result window displays e OD of test sample e Result of test sample e Unit of the test sample result e QC SAVE SEND PRINT and EXIT keys 4 3 1 Add Patient information to test results Clicking the SAVE key will change to following display STANDARD MODE PATIENT DATA MANAGEMENT Pa PATIENT ID ill Il EXIT BAME i SEND CONFIRM e Patient ID can be entered in by keypad Optional Barcode reader If a barcode reader is connected scan the barcode of sample tube the patient ID will read in Press the logo of barcode after reading the sample No Will be displayed e Press the display area of patient ID a small keypad will be emerge Enter the Patient ID e Similarly the data for AGE NAME and SEX can be entered e Clicking the CONFIRM key will save the data and will lead to measurement of next sample 18 4 3 2 Save resultas QC data To save result in QC Click the QC button and the
10. ched or soiled cuvettes for testing on the analyser Always Use calibrated Pipettes to perform the test Follow adequate health safety measures as prescribed by the local country regulatory authority 3 0 ANALYSER OVERVIEW 1 Display 2 Measuring Chamber cover 3 Slot for Smart Card 4 Printer 5 Measuring Chamber 6 DC 12V 7 USB 8 Pipette 9 Scanner 10 RS 232 11 Switch 3 1 Description of Analyser Parts 1 11 1 Display Touch Screen display to operate analyser function of keypad is done by touch screen and display information 2 Reading chamber cover To cover the reading chamber 3 Smart Card slot To Insert the Turbodyne SC Smart Card provided with Turbodyne Reagents Kits for performing test 4 Printer To Print results Levey Jennings plot 5 Measuring Chamber To perform test 6 DC 12V Power supply To connect analyser to power supply 7 USB USB Port For Servicing Aspects Mother Board upgradations 8 Pipette Connector To connect electronic pipette to analyser 9 RS 232 data transfer port 10 Switch For switching the analyser ON or OFF Connect the analyser through the provided power cable by connecting to the power supply connecting port DC 12V at the backside of the analyser below the ON OFF switch Connect the Electronic pipette to the sensor port of the analyser 3 2 ANALYSER OPERATIONS 3 2 1 The analyser operations are carried out with the help of Touch screen display T
11. clean with a cloth moistened with disinfectant 25
12. e is different from test name in the smart card then results cannot be saved in QC Eg If you want to set QC parameters for C Reactive Protein test and its test name in the Smart card is CRP then the name for the QC must also be put as CRP Then QC for the C reactive protein test will be saved in that location e Setting data for QC Select Please input test number window a small key pad will appear Select the location number in which you want to enter QC parameters and click enter key 20 QC Name QC LOT QC EXP QC Target QC Range QC Unit Choice Then click CONFIRM key The display will change to QC MANAGEMENT TH Turbodyne 5G LETTA TET TEL y immoli amp AHophe lar Three levels of QC can be programmed for each test One QC level in each column Input the QC data as described below 4 4 2 For Reviewing QC data QC Name Enter Name of the control vial used for QC for Eg Level I Level Il Level III QC Lot Enter Lot No of control vial QC expiry Enter Expiry date of control vial QC Target Enter Mean value of control vial QC Range Enter lower and higher range of the control vial QC Unit Enter the Unit of measurement of the control vial Choice What is input in QC name the same will automatically appear in the Choice row of respective column Put the location number in Please input Test No of the QC data you want to review and click the Confirm button the display will change t
13. easure lime sec Measuring Unit Mode STANDARD CONFIRM More parameters of the test in the Smart Card will be displayed e Channel 1 Channel 2 channels for turbidimetry nephelometry Delay time Incubation time before adding R2 Measure time 1 first reading time of the test reaction Measure time 2 Second reading time of the test reaction Measuring unit is the unit of measurement of the analyte sample ul sample volume to be used for the test R 1 R 2 ul Volume of Reagent 1 and Reagent 2 to be used for each test Normal range It is the normal reference range If the test result is lower than normal range a flag L will appear with the result If the test result is higher than normal range a flag H will appear with result 15 e Measuring range The measuring range of the reagent If the test result is lower than measuring range a flag LL will appear with the result If the test result is higher than measuring range a flag HH will appear with result Samples with HH flag must be diluted and retested Note e The parameters on the above page cannot be modified These parameters are set by the reagent manufacturer and cannot be edited by the user Turbodyne SC smart card also contains the Calibration data of the reagent The user does not need to perform calibration curve for the reagent It will be automatically read when the smart card is inserted Select CONFIRM key and the following display will a
14. he General Display Key Functions before we switch ON the analyser gt Go to the next page gt lt Go to the previous page gt MAIN MENU Go to the Main Menu gt EXIT Exit from the current page Go to main menu gt SAVE To store results or to input patient data gt SEND Send data to host computer gt PRINT Prints test results Levey Jennings graph gt DELETE Delete stored data 3 2 2 Switching ON the analyser Display shows lip _Group Turbodyne SG lt Turbidimetry e Nephelometry The Display automatically moves to the next page in few seconds Turbodyne SCS Turbidimetry e Nephelometry Performing Self Test Wait for Sec WELCOME The analyser performs self check The counter on the display wait for XXX Sec indicates the time required for Optical stabilization amp warming of the measuring chamber to attain 37 C during self check Skipping this step would produce erroneous results After the self test is completed click the WELCOME button to go to the next page Turbodyne SCS Turbidimetry e Nephelometry MAIN MENU Click the MAIN MENU icon or gt to go to Main Menu Page 4 0 OPERATIONS OF MAIN MENU MAIN MENU SET UP MENU SYSTEM SELF CHELK MEASURE DATA MANAGEMENT eos TH Turbodyne SC Turt irbidimetry Hophelamotry Following are the functions of the Main Menu 1 SET UP MENU To enter into settings mode 2 SYSTEM SELF CHECK To check the status of the analyser whe
15. l 2 linear Value range must be 200 400 The input power supply range must be between the given range 10 4 12 6 V Set 12 0 The temperature range must be between the displayed range 36 5 C 38 5 C Set 37 0 lf any of the values are out of range call our Service Engineer Note System Check must be checked keeping the reading chamber empty Press the EXIT key or MAIN MENU key to go to Main Menu 4 3 MEASURE The MEASURE button is used to perform the test Selecting MEASURE key from Main Menu will open up the following display a Turbodyne sga Waa Bul tage ewe a CONFIRM 14 Insert the Smart Card into the smart card slot of the parameter to be tested The arrow side of the Smart Card must face the display as shown in above picture Click the CONFIRM the following display will appear STANDARD MODE MAGNETIC CARD INFO lest Name Lot Ne Expiry Date Total Mo of Tests CONFIRM The smart card test name with lot No Expiry date and the Total Number of tests for that Reagent Kit will be displayed Note e The parameters on this page cannot be modified e Only the K and the D parameter on the display can be edited by clicking the respective positions K 1 and D 0 is used to correlate results between different systems Click the Confirm button and go to next page MEASURE Channel sample lul Channel 2 R 1 R 2 ul Delay Time sec Normal Range Measure lime sec Measuring Range i 7 m j M
16. lt H flag with result The result is above the normal range eer eet Report the Dilute the sample 1 5 and retest HH flag with result The result is above linearity Multiply the obtained test result with the dilution factor and report LL flag with result The result is below the measuring range nee we eM WUE WET LOS the measuring range Tesamen GAY Hirai Dilute the sample 1 5 and retest P flag with result i a Multiply the result with dilution factor concentration to report 1 1 Remove the card amp reinsert the card properly 2 Clean the Smart card chip Smart card is not inserted properly in the slot 2 Smartcard chip is dirty Defective Smart card Reagent Lot Expiry A with clean cloth and reinsert card 1 3 If the problem persists call the company representative NO TEST AVAILABLE Appears when the card is used after Discard the IC card as it has been TEST OVER completion of the prescribed number of tests completed its programmed usage 24 7 0 Maintenance Precautions Turbodyne SC does not require any special maintenance by the User e Do not switch OFF the instrument keeping cuvette inside e Do not switch ON the analyser keeping cuvette inside e Clean Turbodyne SC analyser with a moist cloth DO not allow liquid to seep inside the analyser e Clean the reading chamber if any liquid sample or reagent spillage regularly e Do not spill hazardous material in the reading chamber If spilled then
17. o QC Name QC LOT QG EXP QC Target QC Range QC Unit Choice QC MANAGEMENT TH Turbodyne 5G Tufpidimoil y Hophelomeiry Clicking on the Choice of a particular QC column will display the data QC test data for that particular QC 21 QC MANAGEMENT 1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 i4 22 30 7 15 23 31 g 16 24 mean GRAPH SD wt CV Turbodyne Turbidimetry Nopholamatry Click on GRAPH to see Levey Jennings plot QC MANAGEMENT E iso 50 Target CONFIRM PRINT Click on Print to print The L J plot with mean SD and CV Note If the number of saved QC result is less than 5 the mean SD CV and L J graph will not be displayed Use Confirm to go back to previous page and keep using the lt key till you go to the Main Menu 22 4 4 3 For reviewing patient data Click on record review fig and the following display will appear RECORD REVIEW a Test Patient IC Dote amp Tin Result Unii DELETE PRINT SEND j aai PAR a a L EXIT CONFIRM The display shows stored patient data 500 test results can be stored The results are displayed with date and time of testing Use gt key to go to the next page and lt key to go to previous page e To search result by test click on the Test button and feed the test name in the window beside Date amp Time button All the results for that particular test will be displayed e To search the result of a particular patient click on the PATIENT ID bu
18. ppear STANDARD MODE i nal Place Cuvette in the Cuvette Holder amp close the lid ae AUTO MIKIN ioe Li sec incubation Foa EXIT CONFIRM The display indicates the volume of R1 and sample to be used for testing and the incubation time Perform the test as described below e Take the prescribed amount of R1 and sample in fresh disposable Turbodyne cuvette provided with turbodyne reagent kit and incubate for stated time at 37 C Externally Insert the incubated test cuvette in the reading chamber of the analyser Do not push the cuvette down in reading chamber Click the TESTING button The cuvette will automatically get into proper position after mixing on pressing the TESTING button The reagent and samples will be automatically mixed well by the Optimix Technology and the display on the counter will become active e After the incubation time is over the following display will appear 16 STANDARD MODE Pipette Re uL to the E uvene TESTING e For Auto start of reading dispense the required volume of R2 with the Electronic pipette ensuring the Pipette plunger is pressed completely when the reagent is dispensed into the cuvette in the reading chamber e The reading will start automatically After initial auto mixing the reaction will be monitored and the result will be displayed at the end of the Measuring time Online reaction curve of the test will be visible on display e Alternatively the TESTING key can
19. ther it is in the normal test condition 3 MEASURE To perform a test sample QC 4 DATA MANAGEMENT To set QC parameters review QC data Levey Jennings plot amp to view Patient Records Delete Print or Send data to host computer 10 4 1 SET UP MENU Clicking the SET UP MENU button will display SET UP MENU SYSTEM SETTINGS PERSONAL SETTINGS PRINTER SETTINGS OTHER SETTINGS MAIN MENU 4 1 1 Clicking the SYSTEM SETTINGS will display SYSTEM SETTINGS STANDARD MODE LS ON OFF Patient L ON OFF SET UP MENU e lf the LIS is ON the data can be automatically sent to the host computer e lf the LIS is OFF then data cannot be sent to the host computer automatically e Patient ID Default it is ON 11 4 1 2 Selecting the PERSONAL SETTINGS key will display PERSONAL SETTINGS SET UP MENU Screen Contrast can be adjusted by using the A amp w keys The setting range is between 1 9 e Initial SET UP is used for setting up Language Date and time format Click the INITIAL SET UP key and the following display will appear TT z E WELCOME INITIAL SET UP anguage english French Spar Date Format DD MM YEAR YEAR MAM DD E mi CONFIRM Click CONFIRM gt key will display WELCOME INITIAL SET UP Language English T Date Format DD MAMA YEAR lime 24 Hours CONFIRM 12 To enter the current date time click on the respective windows A key pad will be emerge to feed the date time Feed the date time and
20. tton at and enter the patient ID and click CONFIRM Results for the Patient ID will be displayed e To search results by date click on the Date amp time button and feed the date All the results will be displayed e To PRINT DELETE or SEND the patient data to host computer select the patient ID s the colour of text will change to blue and then the respective buttons to be used Use the EXIT CONFIRM or lt keys to go to the MAIN MENU 5 0 INSTALLING THE PRINTER PAPER Printer cover a 58 mm thermal printer is inside the printer cover Remove the Printer Cover and install the Thermal Paper 23 6 0 TROUBLE SHOOTING ERROR CAUSE ACTION Instrument does not react Check the mains connection and all plug Check the mains connection and all on connecting to the main adaptor contacts may be faulty plug contacts In Testing 1 3 Please wait for the instrument to After pressing a button In storing parameters complete the work instrument does not react In Printing 4 Replace print paper No Printer paper There may be bubbles in cuvette 1 2 Replace the cuvette Test results are not accurate 2 The cuvette is not clean 3 Replace new reagent Expired reagents or deteriorated reagent When testing high concentr LED ageing 1 Call Service ation sample the test result 2 Beyond the linear range 2 Dilute the sample and retest is not correct L flag with result The result is below the normal range Se epee ane resu
21. umidity The analyser should be connected to the power supply with the power cable provided with the analyser and only if proper earthing connection exists The analyser must be connected to an Uninterrupted Power Supply to ensure non fluctuating power supply Turbodyne SC analyser must be operated by qualified laboratory professionals or authorised healthcare professionals only 2 3 Other precautions during usage Do not use any electro magnetic or radiation devices near the analyzer lf the analyser gives an unusual smell or smoke cut off the power supply and contact company service engineers immediately Keep the instrument away from direct contact with liquid to avoid damage the electrical and optical components of the analyser If any liquid enters in the interior of the analyser cut off the power supply and contact company service engineer immediately Do not switch ON and OFF the power supply of the analyser frequently Always cover the reading chamber during measurement Do not open the reading chamber during a running test Do not move the analyser during a running test Use only TURBODYNE reagents DO NOT USE ANY OTHER REAGENTS Use correct volume of reagents and samples for testing as per Smart Card instruction Incubate the cuvettes with reagent and samples as described in product insert while performing the test Use clean disposable cuvettes provided with the Turbodyne Reagent Kits to perform the test Do not use damaged scrat