DRT-15CE - Watts Water Technologies

image

Contents

1. 10 9 2 Lamp 10 PARTS amp ACCESSORIES 11 WARRANT Y lito tdo 12 Figures Critical Meastiring ATC 4 Potentiometer 8 DRT 15CE 5 10 1 0 SPECIFICATIONS FOR DRT 15CE Ranges NTU Linearity Repeatability Response Power Supply Controls Recorder Output Reference Standard Dimensions Weight Operating Temperature 3 Ranges 0 10 0 100 0 1000 NTU or 1 10 5 100 10 1000 of Full Scale or 1 of Full Scale on either range Virtually immediate in all ranges 6 Volt battery 4 0 amp hours 120 240 VAC 50 60 Battery Charger Combination Range Switch for ON OFF and Range Selection Reference Adjust 0 1mA user adjustable 100 W maximum resistance 0 02 NTU Nominal 11 x 9 1 4 x 5 1 2 27 cm x 22 7 cm x 13 5 cm 4 5 lbs 2 05 kilograms 0 50 C 32 122 F 2 0 PACKING LIST FOR THE DRT 15CE QTY DESCRIPTION 1 Instruction Manual 1 Calibration Standard 0 02 NTU Nominal 1 Battery u V 60 Hz US style Battery Charger 240 V 50 Hz 60 Hz European style 1 complete with screw top Reorder Cat 50051 1 Recorder Plug complete listing of spare parts is on page 11 of this manual DRT 15CE 5 10 3 0 PRE OPERATION CHECKOUT Extreme care
2. R41 N ino VA 15 39N343438 Jay ecuypiqun 396 134 NLN Jsn pe yOu Op 495 SIOA 93YO Aroneg MOT LEN PSHO 354 uep 01 0 ule 001 0 cla 0001 0 LITA 8 DRT 15CE 5 10 8 0 TROUBLE SHOOTING Symptom Meter does not respond when a sample 15 set into the well Possible Cause 1 Lamp is burned out Replace the lamp and recalibrate 2 Printed Circuit Board failure Replace Printed Circuit Board 3 Battery is low Charge battery In the case of 1 or 2 the instrument should be recalibrated The lamp has an extraordinary long life and therefore replacement is infrequent Symptom Reference Adjust does not have enough travel to adjust for the calibration standard value Possible Cause 1 Scratched or rubbed calibration standard container or aged calibration standard Replace the standard 2 Optics have aged Recalibrate 3 Faulty lamp Replace the lamp and recalibrate Symptom The display will not stabilize with the calibration standard in the well Possible Cause 1 Battery voltage too low BAT indicator is ON when the battery requires recharging When the battery is discharged the voltag
3. Toll free 888 203 7248 DRT 15CE 5 10 Page 12 0 3170 Metro Parkway Fort Myers FL 33916 7597 Tel 239 337 2116 Fax 239 332 7643 Toll free 888 203 7248 www hfscientific com
4. CESSORIES FOR DRT 15CE CAT NO DESCRIPTION 60013 ProCal Calibration Standard 0 02 NTU replace annually 21805 Instruction Manual DRT 15CE 50051 Cuvettes Screw Top 3 pk 21084 Lamp Source Assembly 2 pk 70008 Battery 6 volt 70050 Battery Charger 120 volt US style 20850 Photo Diode 19046 Battery Charger 240 Volt European style 21904 LCD Display 20495 Printed Circuit Board Complete 50040 Formazin Stock Solution Kit 20956 Fuse 1A 5 x 20 mm 39071 ProCal Calibration Standards 1 ea 10 100 1000 NTU Replace annually 19045 Auto Adapter 12V 50091 Anti fog kit HF scientific 3170 Metro Parkway Fort Myers FL 33916 7597 Phone 239 337 2116 Fax 239 332 7643 Toll free 888 203 7248 Page 11 DRT 15CE 5 10 11 0 WARRANTY HF scientific inc as vendor warrants to the original purchaser of the in struments to be free of defects in material and workmanship in normal use and service for a period of one year from date of delivery to the original purchaser HF scientific inc s obligation under this warranty is limited to replacing at its factory the instrument or any part thereof Parts which by their nature are normally required to be replaced periodically consistent with normal maintenance specifically lamps reagents desiccant sensors electrodes and fuses are excluded Also excluded are accessories and supply type items Original purchaser is responsible for return of the instruments or parts thereof t
5. DRT 15CE PORTABLE TURBIDIMETER OPERATING amp MAINTENANCE MANUAL Water Quality Measurement Solutions DRT 15CE PORTABLE TURBIDIMETER OPERATING amp MAINTENANCE MANUAL HF scientific 3170 Metro Parkway Fort Myers FL 33916 7597 Phone 239 337 2116 Fax 239 332 7643 Toll free 888 203 7248 DRT 15CE 5 10 FOREWORD HF turbidimeters are manufactured to meet design criteria for nephelometers as described in Standard Methods For Examination of Water and Wastewater HF turbidimeters are approved by the U S EPA as a means to measure the turbidity of potable water waste water and other liquids HF turbidimeters provide a linear display of turbidity throughout all ranges in Nephelometric Turbidity Units NTU HF turbidimeters use solid state electronic components because they resist thermal variation and are not affected by normal line voltage fluctuations HF turbidimeters can be calibrated using HF scientific factory certified ProCal Standards or Formazin Factory calibration is accomplished using HF scientific ProCal Standards which are factory certified traceable to formazin therefore this instruction manual describes the proper procedures for calibration of HF turbidimeters using ProCal Standards HF turbidimeters use Formazin as the primary standard for calibration Therefore this instruction manual describes the proper procedures for calibration of HF turbidimeters using Formazin standards H
6. F turbidimeter manuals are designed to assist the user in taking full advantage of the instrument in a majority of its applications However in the event that unusual circumstances or problems not covered by this manual arise please feel free to contact our local distributor or the manufacturer HF scientific 3170 Metro Parkway Fort Myers Florida 33916 7597 Phone 239 337 2116 FAX 239 332 7643 Toll free 888 203 7248 Our engineering staff is available to help you with your specific needs DRT 15CE 5 10 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 Figure 1 Figure 2 TABLE OF CONTENTS Page SPECIFICATION Sian 1 PACKING LIST FOR THE 5 1 PRE OPERATION CHECK OUT 2 OPERATION AND DESCRIPTION 3 RECORDER OUTPUT cistitis laca 4 CRITICAL MEASURING AREA 4 CALIBRATION PROCEDURES 5 7 1 Calibration 5 7 1 1 ProCal Standards Set Optional Cat No 39071 5 7 1 2 Standard Formazin Solutions 5 7 2 Calibration Procedures TROUBLE SHOOTING 9 MAINTENANCE sir liada 10 9 1 Battery
7. e the display to read 0 02 NTU The unit is now ready for use on any range To make a measurement of a sample clean one of the cuvettes and fill it to within approximately 1 2 12 mm of the top with the sample to be measured Place the cap on the cuvette and carefully clean the outside surface of the cuvette with a lint free wiper such as Kimwipes Place the sample in the well and take the NTU reading directly from display Select the appropriate range for best resolution If the instrument has been subjected to cold below 10 degrees Celsius and then brought indoors it should be allowed to warm up before use since condensation may form on the various lenses Warm up can be aided by leaving the case open and the instrument on for approximately a half hour Page 3 DRT 15CE 5 10 5 0 RECORDER OUTPUT The DRT 15CE has a 0 1 mA Recorder Output The mA output jack is located on right side of the chassis refer to Figure 2 To use connect the 1 8 miniplug provided to your recorder Adjust R17 pot nearest jack to obtain a full scale output compatible to a full scale reading on the DRT 15 Once this adjustment is made the DRT 15CE will always be set up for this recorder Use 10 100 or 1000 NTU standard in appropriate range 6 0 CRITICAL MEASURING AREA The critical measuring area of the sample cuvette is a 3 4 wide band starting 5 8 above the bottom Keep this area clean and free of scratches or abrasion Handle by the top pa
8. e will drop off causing the meter display to drift Recharge battery 2 Cold sample can cause condensation on the cuvette Clean and dry cuvette 3 Unit has not been given sufficient time to stabilize at ambient temperature Allow time for instrument to stabilize Page 9 DRT 15CE 5 10 Symptom No display on instrument at all Possible Cause 1 Battery is dead Recharge battery 2 Fuse has blown Check battery connections and replace fuse with 1A fast acting 5x 20 mm Symptom Low battery indicator on after 8 hour charge Possible Cause 1 Battery is defective Replace battery 2 Charger is defective or is not connected to a valid power source Check for indication on display 9 0 MAINTENANCE The DRT 15CE is not designed for field servicing It should be returned to your local distributor or to HF scientific for any service requirements Be sure to obtain a return authorization number prior to return This will facilitate prompt servicing of the unit The exceptions are Battery and Lamp Assembly replacement This can be done in the field provided the new battery is installed in the same manner as the battery being replaced 9 1 BATTERY REPLACEMENT Should the battery HF catalog 70008 fail it can be user replaced Make certain the instrument is turned off Remove all the accessories in the foam holder Next remove the foam insert by placing a finger in the cuvette hole and pulling the rear of the foam forward t
9. hen up The five Phillips head chassis screws should be removed Remove the chassis from the case by sliding the chassis all the way to the right then pulling up The two screws under the right side of the chassis need to be removed now This will allow for the removal of the battery clamp and the old battery Replace the battery by reversing the procedures described above When connecting the battery be certain that you connect the red wire to the terminal marked and the black wire to the terminal marked If these wires are inadvertently reversed the fuse will blow and must be replaced see Figure 2 DRT 15CE 5 10 Page 10 9 2 LAMP REPLACEMENT The lamp source HF catalog 21084 used in the DRT 15CE has an extremely long life Before replacing the lamp make certain that the battery 1s not in need of a charge and is not defective Prior to replacing the lamp remove the battery as described in battery replacement Remove the lamp wires at terminal block To remove the lamp loosen the two set screws on the outermost barrel with a 5 64 hex wrench and pull the lamp straight out Replace the lamp in the reverse order Make sure the lamp is pushed all the way in The set screws should be snugged up excess pressure could damage the lamp Replace the battery Replace the chassis in the case and recalibrate as described in CALIBRATION PROCEDURES SECTION 7 0 page 5 in this manual 10 0 PARTS amp ACCESSORIES HF scientific PARTS AND AC
10. o HF scientific inc s factory This includes all freight charges incurred in shipping to and from HF scientific inc s factory HF scientific inc is not responsible for damage to the instrument or parts thereof resulting from misuse negligence or accident or defects resulting from repairs alterations or installation made by any person or company not authorized by HF scientific inc HF scientific inc assumes no liability for consequential damage of any kind and the original purchaser by placement of any order for the instrument or parts thereof shall be deemed liable for any and all damages incurred by the use or misuse of the instruments or parts thereof by the purchaser its employees or others following receipt thereof Carefully inspect this product for shipping damage if damaged immediately notify the shipping company and arrange an on site inspection HF scientific inc cannot be responsible for damage in shipment and cannot assist with claims without an on site inspection of the damage This warranty is given expressly and in lieu of all other warranties expressed or implied Purchaser agrees that there is no warranty on merchantability and that there are no other warranties expressed or implied No agent is authorized to assume for HF scientific inc any liability except as above set forth HF scientific inc 3170 Metro Parkway Fort Myers Florida 33916 7597 Phone 239 337 2116 Fax 239 332 7643
11. ot connected the battery requires charging DRT 15CE 5 10 Page 2 4 0 OPERATION AND DESCRIPTION To operate the turbidimeter it 15 first necessary to standardize the instrument Switch to the 10 range and place the Calibration Standard 0 02 NTU in the optical well The EPA recommends that cuvettes used for instrument calibration or sample measurement be indexed For quick and repeatable indexing of the Calibration Standard an indexing ring and locator pin are included with this instrument When shipped the white locator pin is installed in the collar ring around the optical well of your turbidimeter The indexing ring is included in the accessory section of this instrument To index your Calibration Standard slowly rotate the Calibration Standard at least one complete revolution while observing the reading and locate the position of the lowest reading Without moving the Calibration Standard install the indexing ring over the ridged cap of the Calibration Standard such that the arrow on the o ring aligns with the locator pin When indexing the Calibration Standard in the future simply insert the Calibration Standard and rotate it until the arrow on the o ring faces the locator pin Please note that this Calibration Standard is only indexed to the turbidimeter for which it was aligned To standardize first index the Calibration Standard as above Then adjust the Reference Adjust in the appropriate direction to caus
12. rt only See Figure 1 28mm O D Glass Sample Container CRITICAL T MEASURING 3 4 20mm AREA 5 8 15mm Figure DRT 15CE 5 10 Page 4 7 0 CALIBRATION PROCEDURES 7 1 Calibration Standards 711 Standard Set optional Catalog No 39071 HF ProCal Standards are recommended and certified by HF scientific They are traceable to freshly prepared formazin primary standards These standards are very easy to use off the shelf anytime without preparation making them an ideal turbidity standard A Certificate of Traceability is available on request to the HF scientific Customer Service Department HF ProCal Standards may be used for calibration of HF turbidimeters Order from HF scientific inc NOTE Do not freeze standards Do not leave standards in the measuring well for extended periods Do not shake standards Each ProCal Standard Kit contains 0 02 Calibration Standard Certified ProCal Standards 10 00 100 0 1000 NTU Standards are contained in preselected cuvettes with light shield caps A sturdy storage case 7 1 2 Standard Formazin Solutions Calibration of this instrument is based on Formazin a material which is made by polymerization Calibration samples may be obtained by diluting Formazin stock suspension using Turbidity Free water Formazin stock suspension can be prepared by the user Reference Standard Methods For Examination of Water and Wastewater or a ki
13. s in the well always use the screw cap shield to cover the well in order to keep out ambient light To gain access to the trimpots remove the accessories from the foam holder Refer to figure 2 for trimpot identification during the next few steps 1 2 10 11 12 Turn the DRT 15CE to the 0 10 Range Insert the calibration standard and index it as described in Operation and Description Set the Reference Adjust to the maximum up position Adjust R2 Ref Offset trimpot until the display reads 0 18 NTU Set the Reference Adjust to 0 02 NTU Insert the 10 NTU standard and index Adjust R11 0 10 NTU gain to obtain a reading of 10 00 NTU Rotate the range switch to the 100 NTU range Replace the 10 NTU standard with the 100 NTU standard and index it Adjust R12 0 100 gain to obtain a reading of 100 0 NTU Rotate the range switch to the 1000 NTU range Replace the 100 NTU standard with the 1000 NTU standard and index it Adjust R13 0 1000 gain to obtain a reading of 1000 NTU It is not necessary to adjust R37 low battery indicator This is factory set to indicate a low battery condition when the battery voltage is below 5 6 V WARNING R41 is factory set Adjustment of this trimpot could cause damage to battery and or DRT 15CE This completes the calibration of the DRT 15CE Page 7 DRT 15CE 5 10 1078907 4
14. should be taken when handling the Calibration Standard or sample cuvettes as surface scratches or finger smudges will cause analysis errors Handle these items by the top only OVER RANGE BATERY CHARGER CONNECTED READING POLARITY NTU READING REQUIRES CHARGE The battery when new usually requires several cycles of discharging and recharging in order to obtain optimum rated life between charges The turbidimeter provides up to 20 hours of continuous operation as a port able battery operated unit between recharges It is recommended that the unit be turned off between readings in order to obtain longer battery life between recharges If used as a stationary unit leave the charger plugged in but TURN OFF INSTRUMENT WHEN NOT IN USE This will keep the battery at an optimum level at all times If for some reason the battery has been completely discharged the display may not come on at all If this happens turn the unit off and recharge the battery with the battery charger To establish that the unit may be used while charging turn the unit on periodically and observe the lower left corner of the display for the word BAT When it goes off can no longer be seen while the rest of the display is on the instrument may be used while the charger tops off the battery Depending on the state of discharge of the battery it may take as long as 6 8 hrs to fully charge If the BAT indicator is on when the charger is n
15. t can be purchased from HF scientific inc Catalog No 50040 Page 5 DRT 15CE 5 10 Each kit contains Instruction manual 1 liter of 4000 NTU Stock Suspension 1 Gallon 3 79 liters turbidity free water 4 Sample cuvettes 28 mm 4 Light Shield Caps Graduated Pipettes ea in ml 10 ml amp 25 ml 1 Calibration Standard The following table gives the recommended dilutions of the stock suspension Be sure to adequately mix the stock suspension prior to removing a portion for dilution PROCEDURE NTU Value Pipette Amount Base Volumetric Formazin Flask 10 0 NTU 10 0ml of 4000 NTU 1000ml 100 0 NTU 10 0ml of 4000 NTU 200ml 1000 0 NTU 25 0ml 25 0ml of 4000 NTU 100ml NOTE When the prepared samples start to flocculate they are unreliable and fresh ones must be made This will occur more rapidly for the lower value diluted suspensions Prepare 40 NTU and lower standards daily 7 2 ELECTRONIC CALIBRATION USING FACTORY CERTIFIED PROCAL STANDARDS CAT NO 39071 The DRT Turbidimeters have been carefully calibrated at the factory However should the Electronic P C Board the Photo Detectors or the Light Source be replaced recalibration may be easily accomplished at your facility To carry out a complete calibration the following ProCal Standard values are required DRT 15CE 5 10 Page 6 1000 NTU Keep the outside surface of 100 NTU cuvettes clean amp 10 NTU When placing any standard