Revo S 2PH - TMC Instruments
Contents
1. Analog Input A 4 20mA 1000 Digital Input calib only with HB option 12 24V dc ac max 37mA 4 3 Output features power device Nominal Repetitive Voltage peak reverse Latching Max peak Leakage I7T value Frequency Power iss range voltage current one cycle current Uimp Ui Isolation Voltage 4 4 Fan Specification 60 90A Supply 230V Standard Input Power 16W 1 Fan Supply 115V Option Input Power 14W 1 Fan 4 5 Fan Specification 120 210A Supply 230V Standard Power 32W 16W for 2 Fan Supply 115V Option Power 28W 14W for 2 Fan 8 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 5 Installation Before to install make sure that the Thyristor unit have not damages If the product has a fault please contact the dealer from which you purchased the product Verify that the product is the same thing as ordered The Thyristor unit must be always mounted in vertical position to improve air cooling on heat sink Maintain the minimum distances in vertical and in horizontal as represented When more unit has mounted inside the cabinet maintain the air circulation like represented in figure Sometimes is necessary installing a fan to have better air circulation 5 1 Environmental installation conditions 0 40 C at nominal current Over 40 C use the Ambient temperature derating curve Storage temperature 25 C a 70 C Don t inst
2. specialized personnel This procedure is needed only if you change the input type Start TUNE Auxiliary power supply SA Mantain Key CAL pushed and give the power supply Dj H n Release key X O ON when red and yellow e sc led are ON Di e s ON Yellow and Red leds EC are flashing SOC H B M SSR ANALOG Wait for more than 10 sec Within 10 sec from start from start flashing flashing yellow and red leds I yellow and red leds push again momentary CAL Key c 3 Bie The leds will Yellow led only is e a O HB stop flashing flashing apply Sha 0 input Signal E OV for 0 10V 4mA for 4 20mA EM o Signal v Seas Now press CAL Key again 4 is tuned E Red led only is e flashing apply O HB 10V for 0 10V input or 20mA for 4 20mA input Now press CAL Key again Pa d Analog input is tuned 100 Signal End TUNE 20 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 10 Firing type Choose a correct firing type allows to optimize the thyristor unit for the installed load The firing type has already configured in line with customer requirements Zero Crossing for SSR input and Burst firing for Analog Input Caution this procedure must be performed only by qualified persons 10 1 Zero Crossing ZC with SSR input ZC firing mode is used with Logic Output from temperature controllers and the Thyristor operates like a contactor The Cycle
3. time is performed by temperature controller ZC minimizes interferences because the Thyristor unit switches ON OFF at zero voltage VOLTAGE SUPPLY V LOAD VOLTAGE V SSR from controller 10 2 Burst Firing BF with Analog Input The Burst Firing is similar to the Single Cycle but consecutive cycles ON are selectable between 2 and 255 with input signal equal at 50 Burst Firing is a method zero crossing that it reduces the electromagnetic interferences because the thyristor switches at zero voltage crossing The example show the Burst Firing with Burst cycles 4 VOLTAGE SUPPLY V LOAD VOLTAGE V A A AAA A A AAA A A a A fa a a AAA v 9 9 9 A A A AT Aii 100 CD Eng REVO S 2PH 60 210A Solid State Relay 21 CD Automation srl REVO S 2Ph User s Manual 10 3 Burst Firing settings The Burst Firing cycles is already configured in line with customer requirements that are defined in the Order Code However if you wish to change the Burst Firing cycles es from 4 to 8 set the jumpers as below represented Warning Before operate be sure that power and control cables are isolated from voltage sources _lelele am prs AB COAutomation REVO2S5DHB r1 22 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 11 Internal Fuse The thyristor unit have internal fuse extrarapid at low I t for the thyristor protection of against the short circuits The
4. Fuses must have I t 20 less than thyristor s I t The warranty of thyristor is null if no proper fuses are used 11 1 Internal Fuse Fuse Code Current I2T Spare Part ARMS A2 sec mme om xe omo omm om ome se owes ox me omo owes o me so Caution High speed fuses are used only for the thyristor protection and can not be used to protect the installation Caution The warranty of thyristor is null if no proper fuses are used See tab Warning When it is supply the Thyristor unit is subject to dangerous voltage don t open the Fuse holder module and don t touch the electric equipments 11 2 Fuses Replacement Open the cover and remove the screws CD Eng REVO S 2PH 60 210A Solid State Relay 23 CD Automation srl REVO S 2Ph User s Manual 12 Maintenance In order to have a corrected cooling the user must clean the heat sink and the protective grill of the fans The frequency of this servicing depends on environmental pollution Also check periodically if the screw for the power cables and safety earth are tightened correctly See Connection Diagram 12 1 Trouble Shooting Small problems sometimes can be solved locally with the help of the below tab of trouble shooting If you don t succeed contact us or your nearest distributor Indication on Possible reasons of the Symptom front unit symptom Green LED ON light OFF Load current doesn t flow Green LED ON lig
5. Positions 2Ph 120 210A Size 12 6 6 Power Terminals from 60 to 90 A 13 6 7 Command Terminals from 60 to 90 A 13 GZ L herminal block MA OE SSR TInpUE sites t ex coaoaibwo aan 13 6 7 2 Terminal Block M1 for Analog Input or SSR input with HB aaa 13 6 8 Connection Diagram for 3 phases control on 2 phases from 60 to 90 A 14 6 9 Power Terminals from from 120 to 210A 15 6 10 Command Terminals from 120 to 210A 15 5 10 1 Terminal block MI TOF SSRInpblb voc S eis p rete atta eC ERU DEP DIS Sura a sans cs Ch a ae ace dM EIL need me ML d E EE 15 6 10 2 Terminal block M1 for Analog Input or SSR input with HB nennen nhan ern naa aa nnn nnn nnn 15 6 11 Fan Supply terminal M2 15 6 12 Connection Diagram for 3 phases control on 2 phases from 120 to 210A 16 7 LEG status ANG Alaris s nelle e ER REALE RD LCS c Er ER RR RE CE LUN E RR EE Deu n MK aja P 17 8 Heater Break alarm and SCR short circuit HB Option only Leoeeerrrrueee hn nn nnne n nuu h unn nnn u uuu u nnn nnn 17 8 1 HB Alarm contact 18 O INDUC SELINO susieina TR OP PEE STETIT TD TD N UTE D E BP ID 19 9 1 Input calibration procedure 20 TOFIN types E SEE EE E ilaele n DEDE 21 10 1 Zero Crossing ZC with SSR input 21 10 2 Burst Firing BF with Analog Input 21 10 3 Burst Firing settings 22 Ti internal FUSS anemia 23 The warranty of thyristor is null if no proper fuses are used 23 11 1 Internal Fuse 23 11 2 Fuses Replacement 23 2 Main
6. S 2PH 60 210A Solid State Relay TO LOAD CD Automation srl REVO S 2Ph User s Manual 6 9 Power Terminals from from 120 to 210A Warning Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources 6 10 Command Terminals from 120 to 210A Warning Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources 6 10 1 Terminal block M1 for SSR Input Not connected Not connected 7 Input SSR Input SSR 6 10 2 Terminal block M1 for Analog Input or SSR input with HB Aux Voltage Supply for elettronic boards 12 24V AC DC Aux Voltage Supply for elettronic boards 12 24V AC DC Cal Ext 12 24Vdc Cal Ext 12 24Vdc C Common contact relay alarm output see HB Alarm contact for config 6 NC NO Normally Close Open contact alarm relay output see HB Alarm contact for config Control Input SSR 0 10Vdc 4 20mA 8 Control Input SSR 0 10Vdc 4 20mA 6 11 Fan Supply terminal M2 Fan supply 230V standard 115V option Fan supply 230V standard 115V option CD Eng REVO S 2PH 60 210A Solid State Relay 15 CD Automation srl REVO S 2Ph User s Manual 6 12 Connection Diagram for 3 phases control on 2 phases from 120 to 210A Caution this procedure must be performed only by qualified persons SSR Input Only SSR input only SSR Analog Input 1234567 8 or SSR Input with HB A
7. UCT DESCRIPTION Elettric power controll Controllo processi termici UTILIZZO SCOPE OF APPLICATION Thermal controll process Amministratore Unico e Data di emissione 20 04 2010 20 04 2010 Legale Rappresentante Claudio Brizzi ar Issued on CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 1 Important warning for safety The Thyristor unit are integral part of industrial equipments When it is supply the Thyristor unit is subject to dangerous tensions Don t remove the plastic cover Don t use this unit in aerospace and nuclear application Electric Shock Hazard Rischi di scosse elettriche Risque de choque lectrique When thyristor unit has been connected to main supply voltage and is switched off before to touch it be secure that the unit is isolated and wait at least one minute to allow discharging internal capacitors Thus be secure that e access to thyristor unit is only permitted to specialised personnel e the authorised personnel must read this manual before to have access to the unit e the access to the unit must be denied to unauthorised personnel Important warnings Avvertenze importanti attention During the operations with units under tension local regulations regarding electrical installation should be rigidly observed Respect the internal safety rules Don t bend components to maintain insulation distances Protect the units from high temperature humi
8. USER S MANUAL Rev 9 2011 00015 i lll J n Em THE RELAY EVOLUTION M ull N by iS REVO 5 ZPH SOLID STATE RELAY pia 120 TO 210A ib Sa SSS ly JU zu Sill THE RELAY EVOLUTION RAE e E EE SSS THE RELAY EVOLUTION CD Automation srl REVO S 2Ph User s Manual 1 Important warning Tor Safety csvset anaana Aaea I iaia enne 4 2 Basic CONnectionsi isii aa aa a a aak I a na 5 3 Identification and Order Code are lianra iaia nia ELESSE 6 3 1 Identification of the unit 6 3 2 Order Code 7 4 Technical Specifications aan 8 4 1 General features 8 4 2 Input features 8 4 3 Output features power device 8 4 4 Fan Specification 60 90A 8 4 5 Fan Specification 120 210A 8 5 InstallatiOl sscassxte ket a a aU CONI HOS RA KE Rica VR RC NOCR CIC KR UO CU C ca ar E ar FN EO USE RE RN MC RR IC C PRU e OD OR CR cR cn b RR RC M RR ER NC 9 5 1 Environmental installation conditions 9 5 2 Derating Curve 9 5 3 Dimensions and Weight 10 5 4 Fixing holes 10 6 Wirind nstructio ns ine exa are iR Wd x CR S an e RO COR OR RIDE a ON D Rl CD iR S D RERO FEE RR DE C COT D a NR ERES RR OR RU 11 6 1 Power cable torque suggested 11 6 2 Cable dimensions of the Command Terminals 11 6 3 Cable dimensions of the Earth suggested 11 6 4 Terminals Positions 2Ph 60 90A Size 11 6 5 Terminals
9. all at direct sun light where there are Installation place conductive dust corrosive gas vibration or water and also in salty environmental Up to 1000 meter over sea level For higher Altitude altitude reduce the nominal current of 2 for each 100m over 1000m Humidity From 5 to 95 without condense and ice Pollution Level Up to 2nd Level ref IEC 60947 1 6 1 3 2 5 2 Derating Curve MAX NOM xk CD Eng REVO S 2PH 60 210A Solid State Relay 9 CD Automation srl REVO S 2Ph User s Manual 5 3 Dimensions and Weight REVO S 2PH 60 90A REVO S 2PH 120 210A 5 4 Fixing holes REVO S 2PH 60 90 REVO S 2PH 120 210A 10 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 6 Wiring instructions The Thyristor unit could be susceptible to interferences lost by near equipments or by the power supply for this reason in accord to the fundamental practices rules is opportune take some precautions e The coil contactor the relays and other inductive loads must be equipped with opportune RC filter e Use shielded bipolar cables for all the input and output signals e The signal cables must not be near and parallel to the power cables e Local regulations regarding electrical installation should be rigidly observed Use copper cables and wires rated for use at 75 C only 6 1 Power cable torque Jgjgested THe Ed n Wire Range MAX Current Wire Te
10. ate Relay User s Manual REVO S 2Ph CD Automation srl 3 2 Order Code pueuRg Mod WOS Je UO SapAD IL Suun Jsing PUPLLEG J9A40d WOS Je UO SP D 8 Sunia 3SINE Bul aaa andui Zoyeuy yy Ajuo aqepesy 1 939N uue y eaig 19JjE9H GH J9uHOJsuej JUSIND 1 asnj paxij euigui jl QN3511 Z UOISJ9A PIS YO6 lt AOC UP HET NEN NEN pueuue Mod 9908 J UO Sep Ao v Sunia 3SANE IZ SUISSOID 0497 vO6 lt AOLL UEJ Bu jenueyy yous VOO gt UP ON LENT 3 idc t een TOLEN e IP AOLO jenueW UsiBua ETTUTWTT 8 USS HT E CITATI XEN GH EI 12 sasny paxij penuew JI SOSNA pax yndu sojeuy 10 pue gH Wa Suipued Jae u P e AvpCCL UPILOLUY 104 12 jnduj Sojeuy Noy JOP 10 pue gH 3notpiM ueadoin3 104 DINI 32 3983 OA Xny ON sjeaoiddy Ajddns jjoA xny 9L SI vL L CL Lt CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 4 Technical Specifications 4 1 General features Cover and Socket material PolymericV2 Utilization Category AC 51 AC 55b IP Code 20 Method of Connecting Load in Delta Load in Star Auxiliary voltage 12 24V dc ac max 70mA If requested Relay output for Heater Break Alarm 0 5A a 125VAC only with HB option 4 2 Input features Logic input SSR 5 30Vdc 18mA Max ON gt 5Vdc OFF lt 4Vdc Logic input SSR with HB option 4 30Vdc 5mA Max ON gt 4Vdc OFF lt 1Vdc Analog Input V O 10Vdc 15KQ
11. d EO CX CO E 0 Li AUX 12 24V ac dc CAL Ext 12 24Vdc HB Alarm _ 2 Relay Out Input SSR 0 10Vdc 4 20mA P CT HB spon x4 Fan Supply TO LOAD e 1A suitable device must ensure that the unit can be electrically isolated from the supply electromagnetic circuit breaker or by fuse isolator this allows the qualified people to work in safety e 2 Only for the HB option See par Heater break Alarm and SCR short circuit 3 The heat sink must be connected to the earth 4 Only for the Analog Input option the analog input isn t isolated from Aux Supply a series connection between analogue inputs of the units is not possible With AC Aux supply it s not possible connect the zero terminal of Analogue Input to the earth With DC Aux supply is not possible to connect the zero of the power supply with the zero of analog input Load Type 16 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 7 Led status and Alarms LED OFF Load OK LED ON Yellow Load Fault only with HB option LED ON Red SCR short circuit only with HB option LED OFF Load is NOT powered ON LED ON Green Load is powered 8 Heater Break alarm and SCR short circuit HB Option only Caution to work properly the load must be powered at least about 160msec The Heater Break circuit read the load current with an Internal current transformer C T Minimum current is 10 of the curre
12. dity and vibrations Don t touch components to prevent electrostatic discharges on them Verify that the size is in line with real needs To measure voltage current etc on unit remove rings and other jewels from fingers and hands Authorized personnel that work on thyristor unit under power supply voltage must be on insulated board This listing does not represent a complete enumeration of all necessary safety cautions Protection Protezione Protection The unit have IP20 protection rating as defined by the specific international Is necessary consider the place of installation Earth Messa a terra Terre For safety the Thyristor unit with isolated heat sink must be connected to earth Earth impedance should be correspondent to local earth regulation Periodically the earth efficiency should be inspected Our thyristor units have an excellent immunity to electromagnetic interferences if all suggestions contained in this manual are respected In respect to a good Engineering practice all inductive loads like solenoids contactor coils should have a filter in parallel All solid state power controllers emit a certain amount of radio frequency energy because of the fast switching of the power devices The CD Automation s Thyristor unit are in accord with the EMC norms CE mark In most installations near by electronic systems will experience no difficulty with interference If very sensitive electronic measuring equipment or low f
13. ht ON Load current flow also without input Signal Red LED SC light on Yellow LED HB Current flows at light on nominal value but Yellow LED or HB SC is light on Red LED SC light on Thyristor unit doesn t work properly 12 2 Warranty condition No Auxiliary Voltage No input signal Reversed polarities of input signal Fuse failure Load connection interruption Load failure The yellow led HB is light on with HB option Thyristor fault The red led SC is light on with HB option Wrong wiring SCR short circuit HB circuit not tuned Current transformers not properly wired Auxiliary voltage supply out of limits Wrong input signal selection Wrong input signal calibration out of range CD Automation gives a 12 months warranty to its products The warranty is limited to repairing and parts substitution in our factory and does exclude products not properly used and fuses Give auxiliary voltage supply See Connection Diagram Provide to give input signal Reverse the input signal polarity Change the fuse Check the wiring Check the load Change the thyristor module Check the wiring Change the thyristor module Make HB calibration procedure Check current transformers wiring Verify the auxiliary voltage supply Control input signal setting Check input setting Warranty does not include products with serial numbers deleted The faulty product Should be shipped to CD Automatio
14. n at customer s cost and our Service will evaluate if product is under warranty terms Substituted parts remain of CD Automation property 24 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual CD Eng REVO S 2PH 60 210A Solid State Relay 25
15. nt transformer size If load current is below this value the Heater Break Alarm doesn t work properly Heater break Calibration procedure An automatic function sets the Heater Break Alarm The auto setting function can be activated using the CAL button on front unit or supply with 12 24Vdc the digital input Cal Ext See Connection Diagram The Heater Break calibration procedure is performed in this way The Unit gives the maximum voltage output all LEDS are on this means that calibration procedure is active The current value is stored in memory After about 15 second the unit comes back to the initial situation If load current decreases for partial or total load failure sensitivity 20 the yellow LED HB become ON and alarm relay change status If the unit is still in conduction with no input signal LED green OFF it means that there is a short circuit on thyristors and red LED SC become ON If the load has been changed the Heater Break calibration procedure must be done again CD Eng REVO S 2PH 60 210A Solid State Relay 17 CD Automation srl REVO S 2Ph User s Manual 8 1 HB Alarm contact The Revo unit with HB option is supplied with Heater Break alarm contact normally opened NO e In normal conditions without alarm and with auxiliary power supply the contact to the terminals has opened relay coil energized e In alarm condition or without auxiliary power supply the contact to the terminals is closed rela
16. requency radio receivers are to be used near the unit some special precautions may be required These may include the installation of a line supply filter and the use of screened shielded output cable to the load CE 4 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 2 Basic Connections Star wiring with resistive load control on two phases fo 1 73V Nominal voltage of the load Nominal current of the load Nominal power of the load V I p Delta wiring with resistive load control on two phases ie 1 73V V Nominal voltage of the load I Nominal current of the load P Nominal power of the load CD Eng REVO S 2PH 60 210A Solid State Relay User s Manual REVO S 2Ph CD Automation srl 3 Identification and Order Code Caution Before to install make sure that the Thyristor unit have not damages If the product has a fault please contact the dealer from which you purchased the product 3 1 Identification of the unit The identification s label give all the information regarding the factory settings of the Thyristor unit this Date 01 2009 C IMITATION label is on the unit like represented in figure Verify that the product is the same thing as ordered Ser No 12345 6789 001 Mod REVO RM1030 41VZOYOL21 CD Automation s r l d el Sill Il i Il THE RELAY EVOLUTION CD Eng REVO S 2PH 60 210A Solid St
17. rminals YP Ed Lb in N m mm AWG Terminals UL Listed ZMVV 060 Fork Spade Terminal 150 1 Copper wire 180 Screw M8 265 30 0 3 0 250 Compact Solid 210 Stranded 6 2 Cable dimensions of the Command Terminals 0 5mm AWG 18 6 3 Cable dimensions of the Earth suggested 16 mm AWG 6 up to 120A 25 mm AWG 4 up to 210A 6 4 Terminals Positions 2Ph 60 90A Size TOP VIEW DOWN VIEW L1 L3 CD Eng REVO S 2PH 60 210A Solid State Relay 11 CD Automation srl REVO S 2Ph User s Manual 6 5 Terminals Positions 2Ph 120 210A Size TOP VIEW L1 L3 IIT M s Ei S ri M1 DOWN VIEW CD Eng REVO S 2PH 60 210A Solid State Relay 12 CD Automation srl REVO S 2Ph User s Manual 6 6 Power Terminals from 60 to 90 A A C Lu Warning Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources 6 7 Command Terminals from 60 to 90 A L1 T1 L3 3 Warning Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources 6 7 1 Terminal block M1 for SSR Input 6 JNecometed 000000000000 8 e mws 9 Notconnected Fan supply voltage 230V standard 115V option 6 7 2 Terminal block M1 for Analog Input or SSR input with HB Aux Voltage Supply for elettronic boards 12 24V AC DC 12 Fan supply voltage 230V standard 115
18. tenance aiar ATRIA 24 12 1 Trouble Shooting 24 12 2 Warranty condition 24 2 CD Eng REVO S 2PH 60 210A Solid State Relay REVO S 2Ph User s Manual Il Il sill CD Automation srl CD Automation s Controllers Drives amp Automation Via Picasso 34 36 20025 Legnano MI Italia P I 08925720156 Tel 0331 577479 Fax 0331 579479 Internet www cdautomation com E MAIL info cdautomation com D Peed R3 3 S Il Il Dichiarazione di Conformit C C Declaration of Conformity PRODUTTORE PRODUCT MANUFACTURER CD Automation S R L INDIRIZZO ADDRESS Via Pablo Picasso 34 36 20025 Legnano Mi Italia Dichiara che il prodotto Declare that the product RevoS 2ph da 60 a 210A SODDISFA I REQUISITI DELLA NORMA EN60947 1 2008 Specifica di sicurezza EN60947 4 3 2001 EN60947 4 3 2000 Specifica sulle emissioni EN60947 4 3 2000 Specifica sulle Immunita FULFILS THE REQUIREMENTS OF THE STANDARD EN60947 1 2008 Electrical safety Standard EN60947 4 3 2001 Generic Emission standard EN60947 4 3 2000 Generic Immunity standard EN60947 4 3 2000 CDAutomation dichiara che prodotti sopra menzionati sono conformi alla direttiva CDAutomation declares that The products above mentioned they am conforming to the directive EMC 2004 108 CEE e alla direttiva Bassa Tensione low Voltage 2006 95 CEE DESCIZIONE DEL PRODOTTO Unita di controllo potenza elettrica PROD
19. v option 6 NC NO Normally Close Open contact alarm relay output see HB Alarm contact for config 1 2 3 A 5 7 10 11 12 CD Eng REVO S 2PH 60 210A Solid State Relay 13 CD Automation srl REVO S 2Ph User s Manual Caution this procedure must be performed only by qualified persons 6 8 Connection Diagram for 3 phases control on 2 phases from 60 to 90 A SSR Input Only 12345678 9101112 10 QD adag adaugi SSR input only SSR Fan supply Analog Input 123456789101112 or SSR Input with HB A CO CX CO CU d CU ARIAL ALAA Joou REVO LI E 1 AUX 12 24V ac dc 4 CAL Ext 12 24Vdc HB Alarm CT HB option 2 Relay Out Input SSR 0 10Vdc 4 20mA A M gt X4 Fan supply 1 A suitable device must ensure that the unit can be electrically isolated from the supply electromagnetic circuit breaker or by fuse isolator this allows the qualified people to work in safety 2 Only for the HB option See par Heater break Alarm and SCR short circuit 3 The heat sink must be connected to the earth 4 Only for the Analog Input option the analog input isn t isolated from Aux Supply a series connection between analogue inputs of the units is not possible With AC Aux supply it s not possible connect the zero terminal of Analogue Input to the earth With DC Aux supply is not possible to connect the zero of the power supply with the zero of analog input Load Type 14 CD Eng REVO
20. y coil not energized if you wish to change the alarm contact open the cover of the module and set the jumper as shown in the next page Warning Before operate be sure that power and control cables are isolated from voltage AN sources gt E x ha LET T RE 45 U CDAutomation REVO250HB r 18 CD Eng REVO S 2PH 60 210A Solid State Relay CD Automation srl REVO S 2Ph User s Manual 9 Input setting The input type is already configured in line with customer requirements that are defined in the Order Code However if you wish to change the input type ex from 0 10V to 4 20mA set the jumpers as below represented and then do the Input calibration procedure Important The analog input isn t isolated from Aux Supply The series connection between analogue inputs of the units is not possible With AC Aux supply it s not possible connect the zero terminal of Analogue Input to the earth With DC Aux supply is not possible to connect the zero of the power supply with the zero of analog input Warning Before operate be sure that power and control cables are isolated from voltage sources 1 II a LEEREN IER TI Or E LE i CuoAubosmatian REVO SOHB ri aee erage amp SSR Only JP8 close JP9 close CD Eng REVO S 2PH 60 210A Solid State Relay 19 CD Automation srl REVO S 2Ph User s Manual 9 1 Input calibration procedure Warning this procedure can be done just by
Download Pdf Manuals
Related Search
Related Contents
R-S31SSV形・R-S31SSVL形 R-S31SSV形・R Xigmatek Janus Bernadette - Hospitalité Notre Haier HBF1000TEME User's Manual Mode d`emploi pour Mac OS X Leopard Disco de Reagente do Painel Lipídico Piccolo JE8600 Discovery kit for STM32F401 line BreezeMAX Extreme BTS and CPE Software Upgrade Copyright © All rights reserved.