Contents

1. Network Security E mail SNMP Sending Sensor Other Info HTTP GET and POST settings WEB server s address 192 168 10 28 WEB server s name www example com WEB Port 80 Folder containing scripts scripts GUID D6859 045684578 1638 ABE5A381 Sending interval 5 Tip If you send an HTTP GET POST to a server in another network your Gateway IP address in Network tab has to be properly configured HTTP GET Enable HTTP GET sending v Script name get php HTTP GET parameters mypar 10 HTTP POST Enable HTTP POST sending C Script name Fig 15 HTTP protocol sending settings panel WEB server s IP address Enter WEB server s IP address to receive the temperature You can obtain the IP address via ping command from command prompt in Windows you are not certain please contact your Administrator WEB server s name Domain name of the WEB server that will receive the measured temperature If this is a local server no address has to be entered m Temperature is sent in Celsius degrees no matter what unit is set settings Page 20 WWW papouch com Papouch s r o TME WEB port Server s WEB port Usually the port number is 80 or 8080 Scripts Folder on the server Enter a local path to the folder containing the scripts If the script receiving the temperature is on www server net scripts get php enter only this part to the field scripts
2. Activate the e mails sending globally v Send e mail when the threshold is exceeded v Send current measured out value periodically via e mail 30 SMTP server s IP 14 57 126 251 Sender s e mail address sensor example com Recipient s e mail address it example com Temperature in e mail subject 7 SMTP authorization SMTP server requires verification 7 Verification name Verification password Re enter the password Fig 13 E mail settings panel Send e mail when the temperature exceeds thresholds Enter time in minutes This interval sets the period of sending e mails if the temperature is out of limits SMTP server s IP address Enter SMTP server s IP address This server will be used for e mail sending Sender s e mail address Fictional TME address this address will be shown as from in the e mails about the temperature Recipient s e mail address E mail address of the recipient of the alert e mails Page 18 www papouch com Papouch s r o TME Temperature in e mail subject If this field is checked temperature will be directly in e mail subject This is especially convenient when re sending the e mail to a mobile phone Example TME info fridge box 12 3C SMTP authorization You can enter login data if the SMTP server requires sender s identity check 8 SNMP SNMP communication parameters are entered here You can set the SNMP traps activation periodical sending
3. GUID You can enter a string of 40 characters to identify the device If the string is entered it will be added to the end of HTTP GET as a guid parameter Sending interval Enter the interval of sending HTTP GET with measured out values Enter the value in minutes HTTP GET Activate HTTP GET sending If this checkbox is checked HTTP GET sending is active Script name Name of the script receiving HTTP GET HTTP GET parameters If you need to add your own parameters to the THHP GET enter them here Temperature is usually sent with a name temp in HTTP GET If you need to change this name enter a string ending with equal sign temp will be substituted by your string Example settings HTTP GET Parameters are empty get php temp 425 4 Example p 17 is entered in settings HTTP GET Parameters get php p 17 amp temp 25 4 HTTP POST Activate HTTP POST sending If it is checked sending temperature via HTTP POST is active Script name Name of the script receiving HTTP POST www papouch com Page 21 TME Papouch s r o Sensor Parameters affecting measuring Temperature unit values watching etc Network Security E mail SNMP Sending Sensor Other Info Temperature Temperature units Fahrenheit F z Values watch Maximal value 86 Minimal value 77 5 Hysteresis 0 Time between the threshold is exceeded and the message is sent 0 Temperature conversion Followi
4. lt WriteSample gt www papouch com Page 37 TME Papouch s r o lt soap12 Body gt lt soap12 Envelope gt Meaning of the parameters sampleValue measured out temperature in Celsius degrees if the temperature is unavailable for example if the sensor is damaged this parameter is 9999 DassKey muss here the GUID parameter is entered if it is not entered passkey parameter will not appear in the XML message Page 38 WWW papouch com Papouch s r o TME TCP connection TME thermometer enables active and passive IE xi modes of communication via TCP protocol File Edit Setup Control Window Help Passive mode means that the thermometer waits 1E14027 7 a for a connection on a defined port This mode can also be called a Server Mode Active mode means that the thermometer actively connects to a remote IP address and a port and sends the temperature It is possible to define whether the thermometer shall connect only once and keep the connection alive or to connect in regular intervals sent the temperature and disconnect This mode can also be called a Client Mode Fig 29 thermometer values in the TCP IP terminal Passive mode Server This mode is suitable in case a remote system requires a measured temperature from TME and connects to TME actively The thermometer acts as a server and waits for a connection request on its own IP address and port When a connection is established it sends the c
5. If there are more parameters in the address divide them by dash Example http 1 92 168 1 254 index html m e Digital thermometer purely digital display This skin can be switched by parameter n in the address If there are more parameters in the address divide them by dash Example http 192 168 1 254 index html n 1 More languages can be added if required Page 24 www papouch com Papouch s r o TME Info Other information about the device MAC address firmware version and useful links Network Security E mail SNMP Sending Sensor Other Information about the device MAC address 00 20 4A A4 60 32 Firmware version 1 8 Supplier of the device Name Papouch s r o Web site www papouch com E mail papouch papouch com Browser Browser core gecko v 19 System win Links XML file containing current measured out value fresh xml XML file containing current temperature compatible with previous versions temp xml XML file containing current configuration settings xml Simple page viewing current values Meant for PDAs Mobil phones etc wap html Fig 20 Other information panel www papouch com Page 25 TME Papouch s r o TELNET CONFIGURATION Connection Unknown IP address For setting the IP address we recommend using Ethernet Configurator more on page 14 1 Open a window with command prompt In Windows OS click Run and type cmd 2 Make a record to ARP table a Typ
6. a 3 Specific trap H2 trap v1 received from 192 168 1 45 at 21 4 2005 13 01 13 Q Time stamp 0 days 00h 00m 40s 94th E Agent address 192 168 1 45 Port 162 Transport IP LIDP Protocol SNMP 1 Trap m Manager address 192 168 1 42 Port 162 Transport IP UDP eu Community public 3 SNMPv1 agent address 192 168 1 45 Lu Enterprise traps Bindings 3 Binding 1 int temperature t D int32 224 Binding 2 string temperature t D octets 22 4 2B 32 32 2E 34 hex Binding 3 device_name_t 0 octets TME 54 4D 45 hex 3 SNMP notifications received A Fig 35 Trap 2 Regular transmission of the measured temperature value as a trap In the example in Fig 35 the value 224 means a temperature of 22 4 C Page 44 www papouch com Papouch s r o TME Sending e mails TME can send an e mail with information about exceeding the limits Notification when the limit is exceeded can be sent once or repedately until the temperature gets within limits E mail message can be easily forwarded as an SMS using your mobile services provider MODBUS Protocol ModBus TCP is a standard industrial protocol TME can communicate with Complete information and documentation of ModBus protocol is available here www modbus org TME communicates via MODBUS TCP protocol on its own IP address and port 502 It contains a Temperature Register N
7. On the page there is the actual temperature value the name of the sensor if it has been specified and the temperature limits If the temperature value gets beyond a limit the text showing that limit will be flashing There is a Settings button in the upper right corner Button is only visible when administrator is logged in 23 5 C Thermometer TME Mozilla Firefox Soubor Upravy Zobrazit Historie Z lo ky N stroje N pov da C x 5 http 1921681131 23 5 C Thermometer TME x TME T h ermome t er Small window Simple version B Mobile version X Settings Thermometer Last synchronization 17 nor 2009 10 22 39 Logged in Administrator TME ver 1 81 from www papouch com 2005 2009 Fx Hotovo Fig 21 skin mercurial thermometer browser Mozilla Firefox On the site you can select language Czech English appearance mercury digital and units C F 14 WEB interface requires JavaScript turned on Interface is optimized for Internet Explorer 7 0 Mozilla Firefox 3 0 Opera 9 6 and Google Chrome 1 0 Minimal recommended resolution for comfortable view is 1024 x 768 pixels Set the address in the form http IP address of TME For example http 192 168 1 254 if the default configuration of the TME has been preserved The module s pages can be graphically adapted to your requirements www papouch com Page 29 TME Papouch s r o 743 F Ther
8. as a string in Celsius degrees SNMP a MODBUS TCP protocols Automatic temperature sending via HTTP GET request Automatic temperature sending via HTTP POST in XML format 10 Temperature and all settings easily accessible in XML format 11 Wix software for displaying values from TME or other Papouch devices 12 Windows Vista Sidebar Gadget available 13 PHP application containing graphs with temperature development in a set period 14 TME DLL library Including functionalsample and source code for C NET 15 Free sample application for NET to be used to collect data from temperature sensors and presenting them as graphs WEB service and RSS feed TEST PAPOUCH SOAP 21 8 C Testovac idlo TME SOAP rozhran Posledn m en 3 10 2006 10 54 24 C 23 C 22 C 21 C 20 C 19 C Pond l ter St eda tvrtek P tek Sobota Ned le Teplota za posledn ch 7 dni pr m r za hodinu Fig 2 Example of the WEB service http teplomer altairis cz Sample scripts for inputing temperature to your WEB a Register free to MSDN Connection program and gain access to the documentation and source codes af the sample application on http teplomer altairis cz www papouch com Page 5 TME Papouch s r o Options for gathering data from TME 2 WEB o S XML u 1 WAP 1 HTTP GET t HTTP POST XML t E mail SMTP t SNMP UDP t ASCII TCP MODBUS TCP Fig 3 Tempe
9. e New variable consisting of 40 characters added to enable clear identification of TME by a user defined string If this variable is completed it is added as a new parameter into HTTP GET and it can also be used as a variable in the file sent via SOAP protocol e The maximum length of the title extended to 23 characters e The possibility to define the hysteresis of temperature limits Prevents frequent sending of notification of limits violation if the temperature oscillates around a preset limit e E mails notifying of a limit violation can be sent in a preset interval until the temperature returns to the preset range e TME can insert a parameter Host with the target server URL into the header of HTTP communication HTTP protocol v 1 1 this holds for HTTP GET as well as sending XML files to the WEB service e When communication via TCP TME can function not only as a server passively waits for a connection but also as a client actively establishes connection to the defined IP address and port e In TCP mode the TME connection can be established permanently or disconnected after the temperature is sent e XML page tme xml coding changed from iso 8859 2 to iso 8859 1 e The structure of setup via Telnet modified e The error of error messages overlaying on the WEB page corrected Page 10 WWW papouch com Papouch s r o TME Finish Electronics e n metal box made from eloxal coated aluminum Sensor e Ina stainless s
10. 0 Page 50 WWW papouch com Papouch s r o TME WWW papouch com Page 51 TME Papouch s r o Papouch s r o Data transmission in industry line and protocol conversions RS232 485 422 USB Ethernet GPRS WiFi measurement modules intelligent temperature sensors I O modules and custom made electronic applications Address com Strasnicka 3164 PAP O U C H 102 00 Prague 10 Czech Republic Tel 420 267 314 267 420 267 314 268 Fax 420 267 314 269 Internet www papouch com E mail info papouch com www papouch com
11. A com PAPOUCH TME TME PoE Thermometer with Ethernet data transmission ASCII HTTP WEB SMTP e mail SNMP MODBUS TCP XML PoE Power over Ethernet version available 16 January 2013 www papouch com version 1 8 TME Papouch s r o TME TME PoE Datasheet Created 9 19 2005 Last update 1 16 2013 11 08 Number of pages 52 2013 Papouch s r o Papouch s r o Address Strasnicka 3164 102 00 Prague 10 Czech Republic N Tel com 420 267 314 267 pud ad PAPOUCH Fax 420 267 314 269 Internet www papouch com E mail info papouch com Page 2 www papouch com Papouch s r o TABLE OF CONTENTS Basic information ccccceeeceeeceeeceeeceeeceeeceeenees 4 Description fect crates Roz Rot rte bote ER 4 Features cnm inset aside Beste ete neho 5 Options for gathering data from TME 6 Detailed characteristics 7 What is new eee nn 9 PAIS Iz cote ett E a teet ERO RS 11 Package Gorilerits s cortos 12 Accessories een nn 12 CONNECTIONS AEE E bo xe 13 Thermometer settings 14 Ethernet configurator 14 WEB interface setting 14 NGIWO PK pa uote Sep eo prr e N 15 TCP communication 16 Device FeSEt eee 16 SBOLIPITIV eee a tee e AE Et Pee ve Leite iUas 17 E mail MIETEN 18 SMTP authorization es 19 SN
12. about data stored in the local MIB database Management Information Base one of the Internet WWW papouch com Page 41 TME Papouch s r o TME is an SNMP agent It receives commands from a UDP port 161 The administrator asks about data stored in the local MIB database Management Information Base one of the Internet standards which consists of a hierarchic tree structure with the administered data The module does not contain the standard complex database but only a sub tree with data necessary for processing the TME thermometer data Descriptions of the MIB table tree and of SMI Structure of Management Information are attached in Papouch SMI mib and TMESNMP mib text files The programmer should include these two descriptions into the SNMP administrator structure SNMP version 2 0 Data in the MIB tree can be accessed through the name of the object expressed as a series of positive integers separated with dots and describing the path to the object in the MIB tree structure TME as an SNMP agent enables the sending of automatic traps to the administrator via UDP port 162 Using SNMP Include in your SNMP manager the description of the MIB table from the Papouch SMI mib and TMESNMP mib files Then you should set the Read community option to public MIB table Temperature as number Name int temperature Object ID 1 3 6 1 4 1 18248 1 1 1 GET address 1 3 6 1 4 1 18248 1 1 1 0 Description The measured temperature value in
13. according to the previous question You can download these files from www papouch com en Page 46 www papouch com Papouch s r o TME INDICATION ON Indicator green Indication of the power supply voltage Fig 36 upper LED DCD Indicator yellow Connection Indicator yellow Indicates established TCPIP connection Fig 36 lower LED Measure Indicator yellow Flashes when temperature is measured TME PoE only Link Indicator Left indicator on the Ethernet connector Idicator yellow at all times on TME PoE version Nothing disconnected Yellow connected 10 Mbps green connected 100 Mbps Connection type indicator Right indicator on the Ethernet connector Idicator green at all times on TME PoE version Nothing no communication Yellow Half Duplex Green Full Duplex Fig 37 indicators connectors and reset button of TME PoE www papouch com Page 47 TME Papouch s r o HARD RESET If you want to hard reset the TME follow these instructions When hard resetting the device all parameters are set into factory defaults including the IP address TME version with a reset button under the Ethernet connector in a hole 1 2 Disconnect the power supply 3 Turn the power on and wait for 10 seconds Push the button in a hole under the Ethernet connector and hold it 4 5 TME version no hole u
14. another 5V power supply TME version only 2 Then connect the TME to the Ethernet Computer Network using an included or other PATCH cable If you want to connect the TME directly to one PC please use a crosswired cable TME PoE note PC router or switch that you connect TME PoE to must comply with IEEE802 3af standard 3 If your network is out of subnet range or TME IP range please set the IP address of the TME via Ethernet Configurator software You can find this software on your CD or on our WEB site Ethernet Configurator Other Found Devices TIPY IP Address MAC Address How dol set the IP address 192 168 1 84 00 20 4A 91 09 AA Device is connected but it is does not appear in the list 192 168 1 100 00 20 4A 8C 1C 48 You cannot set the IP address 132 168 1 53 00 20 4A A6 77 B9 192 168 1 44 00 20 4A SF F6 DB P Add Device Device Setup Check if the IP address is not assignment to other device Check if the IP address is from the subnet range Fig 8 Ethernet Configurator software 4 After setting the TME s IP address you can connect to it by any WEB browser For example by entering http 192 168 1 254 for default IP address Common Ethernet cable www papouch com Page 13 TME Papouch s r o THERMOMETER SETTINGS You can set up your thermometer using e WEB interface e Telnet protocol see page 26 e For First configuration of the IP address you can use Ethernet
15. degrees Celsius as an integer the measured value multiplied by ten For example 56 9 C is expressed as 569 Temperature as string Name string temperature Object ID 1 3 6 1 4 1 18248 1 1 2 GET address 1 3 6 1 4 1 18248 1 1 2 0 Description The measured value as a text string For example 22 4 Device name Name device name Object ID 1 3 6 1 4 1 18248 1 1 3 GET address 1 3 6 1 4 1 18248 1 1 3 0 Description Thermometer name set by user 19 You can download these files from www papouch com en Page 42 www papouch com Papouch s r o TME Automatic traps The TME enables sending out automatic traps There are two settings for the traps enable disable sending and the receiver s IP address SNMP manager Depending on the settings the traps are sent when the temperature goes out of the preset temperature limits and a trap with the measured temperature value is sent out regularly Trap 1 Temperature outside of limits The trap contains the temperature value in degrees Celsius expressed as an integer the measured temperature value multiplied by ten as a text string the thermometer s name and a specification beyond which temperature the limit occurs This trap is only sent out if the temperature goes beyond the preset limits The trap can only be delivered if the SNMP manager s IP address is set correctly st Trap Ringer console NOON T e if Autoscroll Insertontop Pause l a 4 1 en
16. etc Network Security E mail SNMP Sending Sensor Other Info SNMP settings Allow trap sending v SNMP manager s IP address 135 10 154 15 Send SNMP trap when the threshold is exceeded v Periodical sending of measured out values 60 Read community name public Write community name private Fig 14 SNMP settings panel Enable trap sending This checkbox activates SNMP trap sending SNMP Manager IP address IP address of the server that gathers SNMP messages from devices in the network Send a trap when threshold is exceeded If the temperature exceeds the limits set on Sensor panel SNMP trap will be sent about this event This field is for entering the values only there is nothing displayed after saving SNMP temperature is in Celsius degrees no matter what unists are sent in settings www papouch com Page 19 TME Papouch s r o Periodical sending of the current values You can enter the interval for sending current temperature data to the SNMP manager Temperature is sent as a SNMP trap Interval is entered in minutes For turning this feature off please enter 0 as the interval Read community name Enter SNMP read community name here Write community name Enter SNMP write community name here Sending Parameters for automatic sending of the measured out temperature via HTTP protocol Temperature can be sent as a HTTP GET or HTTP POST in XML format
17. set data port passively TCP client TME establishes connection to the remote IP address actively The connection can be held open indefinitely Keep the connection alive is checked or TME can disconnect after transmitting the temperature Keep the connection alive is not checked Data port Port number TME waits for incoming connection in the TCP server mode Keep the connection alive Checked TME keeps the connection alive Not checked TME establishes the connection every 10 seconds sends the temperature and disconnects Remote IP address Remote device s IP address server mostly TME connects to this device in TCP client mode Remote port Remote device s port number TME connects to this port number in TCP client mode Device reset This button resets all parameters of the thermometer to factory defaults IP address does not change WEB port number will be changed to 80 Page 16 WWW papouch com Papouch s r o TME Security Security settings for accessing the WEB interface Network Security E mail SNMP Sending Sensor Other Info Security settings Current Superadmin s password III Allow mobile view v User password Confirm user password Administrators password Administrators password for confirmation Superadmin s password ecce Superadmin s password for confirmation ecce Fig 12 Security settings panel Current admi
18. ve ened ar ue blue Cable is highly resistant against humidity chemicals and carbohydrates Ethernet interface CONNECT OMe aeae raaa a aaa o TBase 10 100 Ethernet eren d PR RJ45 TME version Sensor connection ee sensor cable attached to the main unit Thermometer electronics Power supply voltage 4 to 6 V max 230 mA Power CONNECtOr eee eee eee eee jack 3 8 x 1 3 mm inside Electronics working temperature range 40 C to 85 C Electronics dimensions 54 x 38 x 24 mm Enclosure material eloxal aluminum COVOIQdB ecc c c LL AA LA SA I AE E IP30 Other parameters www papouch com Page 49 TME Papouch s r o TME PoE verison Sensor connection n detachable sensor cable Ext diameter of the connector 18 5 mm Thermometer electronics Power Supply tese ee dedii ds PoE FOE standard o bnt obediens IEEE802 3af Electronics working temperature range 40 C to 85 C Electronics dimensions eeen 112 x 55 x 24 mm Enclosure material eloxal aluminum Coverage see du dane encanta tenia vada det IP30 Other parameters Lodo y Ree denen PONTO TON 160 g without sensor Default Ethernet settings IP address acoso tus n Uode aM SU RU ded 192 168 1 254 Sibhieb ds Kota rada dooba c tad doa e 255 255 255 0 8 bits C mask GaleWay cci atia o aire tof 0 0 0
19. 53 24 Time stamp 0 days 00h 01m 26s 14th E Agent address 192 168 1 45 Port 162 Transport IP LIDP Protocol SNMP 1 Trap m Manager address 192 168 1 42 Port 162 Transport IP UDP GX Community public 8 SNMPv1 agent address 192 168 1 45 Lu Enterprise traps Bindings 4 S Binding 1 int temperature LO int32 297 4 Binding 82 string temperature LO octets 29 7 2B 32 39 2E 37 hex f Binding 3 device name LO octets TME 54 4D 45 hex Binding 4 waming t 0 octets upper limit of 028 0 75 70 70 65 72 20 6C 69 6D 69 74 20 6F 66 20 2B 30 32 38 2E 30 hex 4 SNMP notifications received Fig 34 Trap 1 the temperature value occurs above the upper limit www papouch com Page 43 TME Papouch s r o Trap 2 Measured temperature value This trap sends the temperature value in degrees Celsius expressed as an integer multiplied by ten and the measured temperature value as a text string The thermometer s name is sent as a text string The trap is only sent if a non zero period is set Temperature trap period for Telnet Keep alive trap interval for the configuration program ato rel ier Auto scroll Insert on top Pause a x 4 l enterprises 1315 78 1 1 0 notification received from 127 0 0 1 at 21 4 2005 13 00 55 4 2 enterprises 1315 78 1 1 0 notification received from 1234cdef 000cf1cb9e56 at 21 4 2005 13 00 55
20. 9 7 C gc 12500 20 0 C 30 0 C Fig 25 Multiple sensors view browser Google Chrome If you wish to view multiple thermometers follow these instructions 1 Create a new file named thermometers html WWW papouch com Page 31 TME Papouch s r o 2 Copy following text to the file lt DOCTYPE HTML PUBLIC W3C DTD HTML 4 01 EN http www w3 org TR html4 strict dtd html head meta http equiv Content Type content text html charset windows 1250 lt title gt Thermometers lt title gt lt head gt lt style gt body background color 340D71 iframe border none width 340px height 240px style body lt iframe src http 192 168 1 254 index html n mini gt lt iframe gt lt iframe src http 192 168 1 121 index html n mini gt lt iframe gt lt body gt lt html gt 3 Number of thermometers depends on number of lines starting by text lt iframe You can add as many as you like Only thing you have to do is to change the IP addresses highlighted red by IP addresses of your thermometers 4 You can save the file to any location but be careful about the absolute path the TME 5 If you have saved the file to your C drive root you can view the page from your browser by entering file C thermometers html Mobile view You can access a mobile version by clicking on Mobile version Mobile version is available on address http TME s IP address wap htm
21. It is built on UDP protocol and ensures guick delivery of control codes and responses between devices on which SNMP applications run lolx File Edit View SNMP Action Tools Window Help Que MIB Ping Remote SNMP agent Split 192 168 1 45 BI vertical MIB tree Query results 3 MIB Tree Welcome to MG SOFT MIB Browser Professional Editi 3 iso E Eg org 3 dod E G internet H E mgmt 6 6 private B E enterprises E G papouchProjekt f tme E a vars K int temperature S string temperature device name E traps int temperature t gy string_temperature_t device name t g waming t quido f eccitace f monitor OID 1 3 6 1 4 1 18248 1 1 1 Fsm O90 B Fig 32 MIB tree SNMP ensures that requests are delivered to and responses from such applications It works independently of specific features in lower or higher level application This protocol is based on three entities administrator which generates commands and receives messages agent which responds to commands and creates messages and proxy which transfers network traffic The SNMP administrator sends requests to the agent s UDP port 161 and receives non requested messages traps from agents on UDP port 162 TME is an SNMP agent It receives commands from a UDP port 161 The administrator asks
22. MP Bartek it e HE et E ET 19 SONCING cic m PER E a 20 HITRPOAGETS Ln 21 HTTIP POST ee t Eel 21 Sensor MN ak ovat SME V S 22 Temperatures watching 22 Temperature calibration 23 CHNO s K P Sects ACA RE Um comm 24 nile RESELLER 25 Telnet configuration ccce nett tet 26 Connection oec e ete rtt e e aes 26 Unknown IP Address 26 IP address is kNoWn 27 Telnet main menu eene 27 Seele te LL LN LU e eat oS 27 Factory Delaults e obe ti bte de 28 Exit without save cernnmmmHH 28 Save and exit eee eee nene 28 www papouch com TME How to connect to TIME eto apri o dsit 29 WEB interface s s n ae a a tn RR Kak 29 Mini VM E 30 DIMMU Vic erat NES ROPA SE SRO E P P S 31 Viewing multiple sensors on a single page 31 Mobile RUIT 32 AMET ori atit oka a ubo 33 Status Sa watt hie LRL ue 33 SINS ucc e Ee ee etant 33 Inserting the temperature value into a website using a script 35 Example of the temperature embedded in a WEB page Re c D eo 35 HEIPZOB D dee trot bu rettet 35 HTTP POST session edu kadeta zased 37 TCP Connection 39 Passive mode Server 39 Active mode Client 39 Message format esee tenens 40 Example including source codes 40 SNMP esee otto tan ii te 41 SONG lal ccart creat etter mba E 41 Using SNMP cipere ee
23. This request is sent as parameters in the message address as a standard HTTP GET parameters Example http www example com get asp temp 25 6 As you can see in the example request is in a format known to the WEB programmers as a standard forms data sending format There is no need to learn new ways and you can use standard mechanism orm name myform action Request is sent in period set in item Sending interval on page 21 www papouch com Page 35 TME Papouch s r o HTTP GET Parameters are following Me C did MAC address of the device NAME Jus Device name defined by user temp Measured out value in Celsius degrees parameter name can be user defined see the example tempV Measured out value in Celsius degrees temps Describes the status of currently measured value 0 valid value currently measured out value 4 measuring error or sensor error means damaged sensor or cable a eee Device identifier GUID identifier defined by user It GUID is not entered parameter id is not sent HTTP GET settings examples Help for entering the path to the script is displayed when cursor is over HTTP GET title Example 1 Exa What you need to process There is a script temperature asp on your server awaiting the data from TME Full path to the script is http www example1 com temperature asp Script expects the temperature in temp parameter Solution You need to set up these
24. ameter tr5 It also expects an id variable to identify the thermometer This parameter is stored in GUID for now we have a string 98ED78B Solution You need to set up there items WEB server IP address 28 225 184 31 Server name in trece www example2 com WEB port a ois dass inn uiid 80 Script folder scripts OUID rea ee ee 98ED78B Script alti iuc oral pi eden process php HTTP GET parameter tr3 Result URL address when temperature is _ 5 C http www example2 com scripts process php tr3 5 0 amp tempV 5 0 amp id 98ED78B amp tempS 0 amp mac 00204A9AE5E2 amp name HTTP POST Parameters of this type of request are sent as a body of an XML message XML is formatted according to SOAP v 1 2 protocol Request is sent in period set in item Sending interval on page 21 Example message Head POST post asp HTTP 1 1 Host www example com Content type application soap xml charset iso 8859 1 Content length real body length Body lt xml version 1 0 encoding iso 8859 1 gt lt soap12 Envelope xmlns xsi http www w3 org 2001 XMLSchema instance xmlns xsd http www w3 org 2001 XMLSchema xmlns soapl2 http www w3 0rg 2003 05 soap envelope gt lt soap12 Body gt lt WriteSample xmlns http www papouch com TME Sensors gt lt sampleValue gt 24 7 lt sampleValue gt lt passKey gt 98ED78B lt passKey gt
25. configurator Ethernet configurator Ethernet configurator can be used to set TME s IP address You can find the software on your CD or on our WEB site www papouch com Before running the program please connect your TME to a switch hub or router or directly to your PC using crosswired cable Program is in English and Czech language It also contains a small help telling you what you need to know when setting your TME s IP address You can see the program screen on previous page in Fig 8 WEB INTERFACE SETTINGS To enter settings push Settings button in upper right corner of TME main WEB page Fig 9 Settings button on the main page Settings are arranged in eight panels e Network Network interface configuration IP address subnet mask TCP channel e Security Access passwords settings e E mails e SNMP e Sending sending of the measured temperatures to your server using HTTP GET and POST XML e Sensor thresholds hysteresis and units settings e Other device label WEB interface language and appearance settings e Info device information Page 14 www papouch com Papouch s r o TME Tips for settings e You can view the context help by pointing the cursor at the item It is also displayed when cursor is over the headlines marked with a question mark at its end TCP communication TCP data mode TCP RE r Data port TCP server Device expects data Keep the connect
26. d temperature is also available in XML file or it can be sent as an http POST in XML format fo rfurther processing in a WEB service All temperature acquisition methods are on page 6 TME is configurable via WEB interface TME is powered from an external PSU 5V TME or directly from ethernet network according to IEEE802 3af standard TME PoE 4A S OTAS PY ii S ODO M X i O M W 5 O o E mail SNMP mec e mali A i poer XML ME o PSU 5V Fig 1 Connection and Access to the TME in computer network Page 4 www papouch com Papouch s r o TME Features Measurement of temperatures raging from 55 C to 125 C resolution 0 1 C Data transfer via TCP IP protocols 10 100 Ethernet WEB based Configuration Temperature sensor in the metal rod with IP68 coverage Sensor is connected to the TME by highly resistant silicon cable 5V DC powered wall plug PSU included TME Powered form 5V DC Wall plug adaptor included TME PoE Powered directly from Ethernet no PSU required Can be mounted to DIN rail Temperature watching M pr gre SA qu ch 9 Internal WEB page containing current temperature Mobile WEB WAP page for mobile viewing Mini browser window containing current temperature Multiple TMEs temperatures can be displayed on a single WEB page Automatic e mail sending when pre set thresholds are overrun Sending the temperature via TCP data channel
27. ding the upper limit It can be 0 current value is below or equals upper limit dons current value is above upper limit Describes status of dropping below the lower limit It can be Duos current value is above the lower limit j current value is below or equals the lower limit XML file compatible with the old versions is still on the same address http IP adresa teplom ruj tme xml 17 This attribute is for reasons of backward compatibility with previous versions also repeated in the tag sns www papouch com Page 33 TME Papouch s r o unit Currently set temperature units 0 Celsius degrees Tas Fahrenheit degrees val Current value in degrees Celsius multiplied by a factor of 10 Validity of the value describes status attribute min max Lower and upper limit of the temperature set by user Temperatures are always in degrees Celsius and multiplied tenfold Page 34 www papouch com Papouch s r o TME Inserting the temperature value into a website using a script The temperature value from the TME can be inserted into a website using a scripting language such as PHP or ASP which processes the value from the thermometer as an HTTP parameter of the GET request or HTTP POST The thermometer periodically calls the script on an Internet or intranet server with the actually measured temperature value in the GET or POST parameter On the server this value can be stored as a variable and further
28. e arp d and confirm by Enter That deletes current ARP table b Following command assigns IP address to MAC address arp s new ip address MAC address example arp s 192 168 1 254 00 20 4a 80 65 6e 3 Open Telnet by typing telnet and pressing Enter 4 Type open new ip address 1 and confirm 5 Terminal shows an error message after a moment Nevertheless this action is essential for correct IP address ARP entry 6 Connect to the IP address of the TME by typing open IP address in dot format 9999 and Enter 7 Now you have entered to the configuration of TME IP address is not yet set It needs to be set in menu Server Configuration IP Address 8 If the IP address is valid TME writes welcoming information ending by text Press Enter for Setup Mode Now press Enter or the configuration will be terminated 9 Device writes complete settings 10 At the end of the entry you can see Change setup text containing groups of parameters that are configurable For changing the network parameters choose Server Here you can set a new IP address and other parameters 13 Telnet client is not standardly installed in OS Windows Vista You can install it by doing following a Open Control panel add or remove programs b On the left click on Add remove Windows functions You have to have administrator s rights to do this c Windows Functions window will open Check Telnet client and confirm Telnet client will b
29. e installed to your system Page 26 WWW papouch com Papouch s r o TME IP address is known 1 In OS Windows click on Start Run and type telnet and confirm 2 Connect to the IP address of the TME by typing open IP address in dot format 9999 and Enter 3 If the IP address is valid TME writes welcoming information ending by text Press Enter for Setup Mode Now press Enter or the configuration will be terminated 4 Device writes complete settings 5 At the end of the entry you can see Change setup text containing groups of parameters that are configurable For changing the network parameters choose Server Telnet main menu You can choose the menu items by pressing the number before them and confirming by Enter Menu structure is Change Setup 0 Server 7 Defaults 8 Exit without save 9 Save and exit Your choice Server Basic Ethernet settings Following items are in this part IP Address 192 168 001 122 Set Gateway IP Address N Netmask Number of Bits for Host Part O default 16 Change telnet config password N WWW papouch com Page 27 TME Papouch s r o IP Address TME s IP address Enter the numbers separately and divide them by Enter Default 192 168 1 254 Set Gateway IP Address Gateway IP address Type Y in the Set Gateway IP Address item to change the address Enter the numbers separately and divide them by Enter Netmask You can s
30. e of the set limits Cf also page 43 6 TCP protocol The thermometer behaves as a server and waits for a connection request on the set IP address and port Upon connecting it sends the Client temperature data in ASCII format Cf also page 39 7 WAP page for PDA or mobile phone Entering an IP address of the thermometer in the form http IP address wap html on a mobile phone or PDA with WAP browser opens a simple page with current data from the TME thermometer current temperature thermometer name and limits if they are set Cf also page 32 8 WebService XML HTTP POST Information from TME can be periodically sent as an HTTP POST in an XML format There is no need to spend time on programming the communication protocol etc It is only necessary to process the received XML file See also page 37 9 Via MODBUS TCP protocol TME can communicate via MODBUS TCP protocol See also page 45 Detailed characteristics Ethernet Part IP address subnet mask gateway and port number configuration Automatically sends current value via TCP connection every 10 seconds TCP data connection can operate in both client and server mode TME can keep the connection alive automatically Local and remote port are configurable Device can be set to factory defaults by a button in WEB interface Security Three security levels user temperature viewing and administrator configuration superadmin sensor calibration Each lev
31. el has own password WWW papouch com Page 7 TME Papouch s r o E mails e An e mail can be sent when the threshold is exceeded E mail can be forwarded to a mobile phone E mails can be sent periodically when the threshold is exceeded e SMTP authorization SNMP e SNMP trap can be sent when the threshold is exceeded e Periodical sending of the measured out value e Configuration of the read and write community e HTTP GET and POST e Periodical sending of the current measured out value to your WEB server via a simple HTTP GET request or HTTP POST in XML format e Unique identification can be set GUID string of 40 characters e You can input your own parameters to the GET e Separate scripts for POST and GET Temperature measuring e Temperature units Celsius or Fahrenheit e Upper and lower threshold can be set If the temperature gets out of the range TME sends an email or SNMP trap according to the settings e Hysteresis can be set for temperature thresholds in regions with fluctuating temperature MODBUS TCP e TME can communicate via MODBUS TCP protocol Hardware e Measuring temperatures in range 55 to 125 C e Sensor cable length 3 m up to 20 m possible if required e Silicon cable and metal enclosed sensor e 5V powered wallplug adaptor included e TME powered from 5V external PSU Cable and sensor directly attached to the main unit e TME PoE PoE powered Cable and sensor detachable from t
32. et here how many bits from IP address make the network part Subnet mask is entered as a number of bits determining range of possible IP addresses of the local network If for example 2 is entered subnet mask is 255 255 255 252 Entered value indicates number of bits from right Maximum is 32 Default 8 Example Mask 255 255 255 0 binary 11111111 11111111 11111111 00000000 gt number 8 Mask 255 255 255 252 binary 11111111 11111111 11111111 11111100 number 2 Change telnet config password Enter new Password This item sets the password that is required before entering the Telnet configuration or via WEB interface Administrator s password Type Y at Change telnet config password to change the password Factory Defaults By pressing number 7 you can set the device to factory defaults This option sets the TME to defaults IP address does not change WEB port number will be changed to 80 Exit without save Ends the telnet session without saving Save and exit This choice saves the changes If some settings are changed device restarts That may take up to 30 seconds Page 28 WWW papouch com Papouch s r o TME HOW TO CONNECT TO TME A brief overview of methods for obtaining temperature values from the TME thermometer is on page 5 WEB interface After setting the thermometer s IP address in the Internet browser you will see the page from Fig 21
33. he main unit Other e Name the device as you like e WEB interface language Czech or English This function depends on your mobile service provider More languages can be addend if required PoE power over Ethernet Standard IEEE 802 3af that allows power devices in the network via data cable Page 8 www papouch com Papouch s r o TME Two skins available Digital and Mercury thermometer Simple WEB display possible For example you can view multiple TMEs on a single WEB page using HTML iFrame element Mini WEB page with a simple display JavaScript window WEB interface requires JavaScript turned on Interface is optimized for Internet Explorer 7 0 Mozilla Firefox 3 0 Opera 9 6 Google Chrome 1 0 iPhone and Android Minimal recommended resolution for comfortable view is 1024 x 768 pixels What is new Version 1 88 New parameters mac name tempV and tempS in HTTP GET New parameters ocation and mac in XML Version 1 87 WEB interface made compatible with latest platforms like IE9 FF4 and mobile platforms iPhone and Android User login pops up only if the password is required Configurable delay between temperature overrun and e mail alert User temperature calibration by line equation y ax b This setting is protected by a special separate password E mail addresses can be up to 40 characters long E mail subject edited for the best result when re sending e mail to a mobile phone Versio
34. ion alive connection on its own IP address y and data port Remote IP address TCP client Device connects to a 25 127 remote IP address and port Choosen TCP mode does not Remote port eaffect other settings in the device Fig 10 Context helps for the settings menu items e Settings window is movable by dragging it by the upper right corner e You can also enter the settings menu by pressing S when the browser window is active e Settings menu can be closed by Esc key Network Network settings for the thermometer and the TCP data channel Network Security E mail SNMP Sending Sensor Other Info Network settings Device s IP address 192 168 1 254 Netmask 255 255 255 0 Gateway IP address 192 168 1 201 WEB port 80 r TCP communication TCP data mode TCP client Data port 10001 Keep the connection alive v Remote IP address 145 67 25 127 Remote port 75 Reset save Close Fig 11 Network settings panel Device s IP address Thermometer s IP address In case you are not sure if the IP address is correct please consult your Administrator www papouch com Page 15 TME Papouch s r o Subnet mask Subnet mask of the network TME is connected into Gateway IP address Network gateway IP address TCP communication TCP data mode TCP server TME is awaiting the connection on the pre
35. items WEB server IP address 218 25 14 3 Server name v www example1 com WEB port z n eee ene 80 Script fold r e eee ES s SCHL NANG o ood edes temperature asp HTTP GET parameter Result URL address when temperature is 25 6 C http www example1 com temperature asp temp 25 68temp V 25 68tempS 08mac 00204A9A E5E28name mple 2 What you need to process There is a script process php awaiting data from TME Full path to the script is http www example2 com scripts process php It expects an id variable to identify the thermometer This parameter is stored in GUID for now we have a string 98ED78B Server also expects constant variable sts ok Solution You need to set up there items WEB server IP address 28 225 184 31 Server name ee www example2 com WEB pott edet e 80 SCrIDETOIdGE os aoo o eite s scripts GUID se erdt rette e 98ED78B Page 36 WWW papouch com Papouch s r o TME Script ANG PRENNE process php HTTP GET parameter tst 5 Result URL address when temperature is 2 7 C http www example2 com scripts process php tst 58temp 2 7 amp temp V 2 78id 98ED78B4 tempS 0 amp mac 00204A9AE5E2 amp name Example 3 What you need to process There is a script process php awaiting data from TME Full path to the script is http www example2 com scripts process php Script expects the temperature as a par
36. l Sony Ericsson en 1054 Ethernet thermometer Location Papouch Praha Current 15 6C Upper limit 30 0 C Lower limit 10 0 C iP thermometer TME from www papouchcon Vybrat BEINI S500i Fig 26 mobile view Page 32 WWW papouch com Papouch s r o TME XML file From the TME thermometer you can get the currently measured temperature value the temperature limits and the thermometer s name in a text file in XML format The file is at http IP address of thermometer fresh xml for example http 192 168 1 254 fresh xml for the default settings of the thermometer lt xml version 1 0 encoding ISO 8859 1 gt root xmins http www papouch com xml TME act sns max 1250 min 550 val 252 unit 0 lo 0 hi 0 status 0 type 4 id 1 gt status mac 00204A9AE5E2 location Storage lt root gt Fig 27 view of an XML text There are following tags in the XML file status location User defined name of the thermometer mac MAC adresa za zen sns id Number of the quantity Always number 1 type Quantity type There is always the number 4 which represents the value multiplied by ten status Describes status of the measured value It can be 0 valid value currently measured out temperature pete waiting for first measuring 4 measuring error or sensor error means damaged sensor or cable hi Describes status of excee
37. lient temperature data in ASCII format compatible with Spinel protocol xi The process of setting these items can be found in rcppp h r starting on page 16 chapter starting on pag Host 192 169 1254 Service Telnet TCP port 10001 This example illustrates a connection using Tera Term C SSH A program Me Example of a connection via terminal program Establish a new connection File New connection A 59d dialog shown in the picture is displayed Here you can select TCP IP and enter the thermometer IP address and defined port The picture shows default values for the ee thermometer Fig 30 New connection Confirm the dialog When a successful connection is established a window shown in the picture appears It displays temperatures which are regularly sends by TME every 10 seconds Active mode Client This mode is suitable in case one server expects temperatures to be sent from several thermometers or in case TME has not a fixed IP address or is placed behind a firewall or router 8 Tera Term terminal can be downloaded from http www ayera com teraterm www papouch com Page 39 TME Papouch s r o Message format The temperature value message is sent in the following format B1E1 sign degrees tenths enter SIGN eee 1 Byte or sign degrees 3 Byte temperature in degrees Centigrade Celsius always a three digit nu
38. limit 30 4 20 PS Rf a Lower limit o o o N Co histeresis Fig 17 Temperature hysteresis Temperatures marked as info are temperatures where a message is sent about exceeding limits Delay between temperature overrun and e mail alert Enter time in minutes before the e mail alert is sent after a limit is overrun The overrun state must persist the whole time Enter number 0 to 255 If you enter 0 there will be no delay Temperature calibration Following settings are only accessible from superadmin login Constants Temperature is calculated by a line equation using two user defined constants Temperature conversion Temperature from the sensor converts based on following formula y 1 x 0 Fig 18 temperature calibration appearance from a standard login www papouch com Page 23 TME Papouch s r o Other Network Security E mail SNMP Sending Sensor Other settings Name of the device My Thermometer Language English Skin Digital thermometer Fig 19 Other parameters settings panel Device name This string can be used to label the thermometer for example by its location etc Language Interface language English and Czech available Skin WEB page thermometer skin These options are available e Mercurial thermometer imitates the mercurial thermometer This skin can be switched by parameter m in the address
39. mber filled with zeros from the left as necessary undue R 1 Byte decimal point tenths n 1 Byte tenths of degree SGS spiss 1 Byte terminating character Enter DEC 13 HEX 0x0D All characters are sent in ASCII format An example is shown in the Fig 29 On Error sending TME this string BlElErr enter 38 E EXE merrni 1 Byte terminating character Enter DEC 13 HEX OxOD All characters are sent in ASCII format Error can be sensor s internal error or broken sensor cable Example including source codes At www papouch com en a demo program can be downloaded free of charge showing how the temperature measurement works You can also download free of charge its complete commented source code for Delphi 7 nix M Connection settings Device IP address 192 168 1 250 Port 10001 ixi Connection settings Device IP address gt o Bis Port 10001 024 0 C Fig 31 demo program After opening the program you can fill in the IP address and communication port of the thermometer and push the Connect button If the connection to the thermometer has been successful the measured temperature value is displayed in the bottom part of the window Page 40 WWW papouch com Papouch s r o TME SNMP General SNMP Simple Network Management Protocol is a standard protocol for management of various devices in an Ethernet network
40. mometer TME Windows Internet Explorer GO Ei mp noz1681131 x Googte 2 xk fe 84 743 F Thermometer TME Kp E v A Str nka v C N stroje TME T h ermom et er ex Small window Simple version B Mobile version x Settings Thermometer 74 3 F 54 9 F 125 Administrator TME ver 1 81 from www papo Internet Chr n n re im Zapnuto Fig 22 skin digital thermometer browser Internet Explorer Mini view By clicking on Mini view the small window is opened containing small WEB page as shown in Fig 23 Venku TME Google http Fig 23 TME mini WEB browser Google Chrome Page 30 www papouch com Papouch s r o TME Simplify You can view simple form of current view by clicking Simplify This form is especially useful when viewing multiple sensors on a single page 4Q 25 5 C Sklad jih TME Opera Soubor pravy Zobrazit Z lo ky Pom cky N stroje N pov da x X 25 5 C Sklad jih TME http 192 168 1 121 index html n mini v Google Sklad jih 2933 20 0 C 30 0 C je H Q100 Fig 24 simple view skin digital browser Opera Viewing multiple sensors on a single page If you have more than one TME you can view them both on a single page like this Thermometers x Mar lt Q fi Y file C thermometers html Venku Sklad jih 1 0 C 2
41. n 1 84 PoE version addend HTTP GET parameters shifted Host parameter Version 1 82 Maximum segment size in TCP decreased from 14 000 to 640 bytes Corrected bug Reseting Server s IP address on the Sending panel after resseting the device Corrected bug Equal sign recognition at the end of HTTP GET parameter when it is being sent Version 1 8 High temperature resistant silicon cable is a standard Metal enclosed sensor is a standard Coverage IP68 All New WEB interface Device fully configurable via WEB SMTP authentication available Two level WEB security Automatic keeping alive of the connection Temperature sending in TCP mode is 10 seconds All intervals are entered in minutes Language and units settings are stored in the device Mini view can be opened in any browser now It is not a HTA application for Internet Explorer anymore Maximal length of TME label is 16 characters www papouch com Page 9 TME Papouch s r o e WEB interface can display multiple thermometers on a single page e XML file for HTTP POST is pre set by default Version 1 7 e MODBUS TCP protocol Version 1 6 e Support for sending information to the WEB service via SOAP protocol XML easy processing of values from TME in NET e WAP pages for mobile phones or PDA e User defined XML file sent via HTTP POST e Possibility to change the port number for WEB This enables to easily access TME behind the firewall router etc
42. nder Ethernet connector Release the button Hard reset done Disconnect the power supply no Open the box by unscrewing all screws A Turn the power on and wait for 10 seconds O1 Shorten the jumper inside the device and hold it Open the jumper and assemble the box O Hard reset done TME PoE version 1 2 Disconect the Ethernet cable 3 Connect the Ethernet cable Press and hold the Reset button 4 5 Release the Reset button Hard reset done Page 48 www papouch com Papouch s r o TME TECHNICAL PARAMETERS Common parameters Temperature sensor Sensor TPO cocco trece tU o doga uo a semiconductor Measuring range 55 C to 4125 C ACCUIACY oio ieu E 0 5 C within the range 10 C to 85 C otherwise 2 C Temperatures drift eee 0 2 C over 1000 hours at 125 C DIMENSIONS esie redi Debt eite Rae obiote 5 7 0 1 mm diameter 60 mm length Cover MALO z ein ten eines Stainless Steel 17240 Coverage ERR IP68 indefinite submerge into 1m depth Resistance to external pressure to 2 5 MPa Sensor cable Misi snctdrate Sst adocped Nia tadseatede edd silicon Wire insulation eee eee FEP polymer MC AFEP OTO eee FIR LM IM EET TECH 3 m standard up to 20 meters upon request Working temperatures range 60 C to 200 C Cable diameter eee 4 3 mm 0 1 mm COIBL uu cna dee on toned
43. ng parameters will be used for temperature conversion according to formula y a x b If you want no conversion enter number 1 as a parameter and number 0 as b parameter Parameter a Parameter b 0 Fig 16 Sensor settings panel Unit for measured temperature Unit displayed on the WEB page Temperatures watching Maximum value When this value is exceeded according to other settings e mail SNMP trap etc will be sent Temperature on the WEB page will be highlighted as a warning that some limit was exceeded Enter the value in units set in Temperature units setting Minimum value When the temperature drops below this value according to other settings e mail SNMP trap etc will be sent Temperature on the WEB page will be highlighted as a warning that some limit was exceeded Enter the value in units set in Temperature units setting Hysteresis Hysteresis applied for set thresholds 11 If the units are Fahrenheit degrees F there might occur an error of 0 1 F in some cases Page 22 www papouch com Papouch s r o TME Value is entered in whole degrees and it applies under upper limit and over lower limit see Fig 17 Without histeresis C 40 Z M M A ZN f Upper limit 30 20 1 uu Adis Ng pennas Lower limit 5555 52 Eg h Ss h h h gt a o O O Oo o o o A NO A G1 o N With histeresis t C 40 T 3 M M Ey XM Upper
44. nistrator s superadmin s password If administrator s superadmin s password has already been saved enter it here Otherwise no password changes are allowed Allow mobile view WEB page for the mobile view accessible at wap html is not secured This setting can allow or disallow the mobile view User s password Enter password for user access This level only allows viewing the current temperature Access to settings is not allowed User Name is always user If the user s password is entered Administrators password has to be entered as well To cancel the password leave both fields empty Administrator s password Enter administrator s password here This level also allows access to the settings Administrators name is always admin Do not fill the name if there is no password This field is for entering the values only there is nothing displayed after saving www papouch com Page 17 TME Papouch s r o To cancel the password leave the fields empty Superadmpassword and verification Enter the superadmin password This level allows you to access all settings including sensor calibration Temperature is calibrated by line equation y ax b Superadmin name is always sadmin Superadmin password cannot be cleared The default password is 1234 E mail E mail sending settings Network Security E mail SNMP Sending Sensor Other Info E mail settings
45. o 30001 of a signed integer type and a Status Register No 30002 of an integer type Both are an Input Registers The Temperature register contains the currently measured temperature in degrees Celsius multiplied by ten the temperature of 12 3 C expressed as 123 If an error occurs the register shows the value 9999 The Status Register shows the value 0 If an error occurs e g a temperature sensor error the register shows the value 1 www papouch com Page 45 TME Papouch s r o FAQ What needs to be set for my thermometer to work in the network Only thing you have to set up for TME to work is the network parameters for your Network IP address and Subnet mask Settings are described for Windows OS 1 Connect your TME to the network and run Ethernet Configuratoe program see Fig 8 from your CD 2 Click Add device and enter MAC address of your TME and desired IP address 3 Click Set 4 Now you can open the WEB interface of your TME using any browser How do I get TME s IP address 1 Default IP address is 192 168 1 254 If you have changed the address before of you cannot connect to the TME follow these instructions 2 Run Ethernet Configuratoe program see Fig 8 from your CD If your TME is in the network and has a compatible IP address you will be able to see it in visible devices list 3 If you cannot see the TME is the list check the connectiou and assign it a new IP address
46. processed for example stored in a log displayed on the website etc The TME settings contain the script path and the script calling period If a measurement error occurs the temperature value cannot be read from the temperature sensor on the cable the TME sends 9999 as a temperature value If the GUID parameter is filled in in the thermometer setting this ID is sent to the HTTP server as a further parameter id in GET or guid in POST Period can be set from range 1 to 1440 minutes Resolution 1 minute Example of the temperature embedded in a WEB page B http rymarov cz Pr Box R ma ov Virtu ln proch zka Pod heslem nen to z vod ale prov rka osobn zdatnosti fyzick p iprav sobotu 10 z 2011 ji XXXVI ro n k turistick akce R ma ovsk pades N me ka Start J delna Z R ma ov ul m je od 6 00 hod do 10 00 hc po as A Propozice z vodu Pietn m sta Online teplom r 13 9 2011 14 40 20 2 C V stava v p stk esk zahr dk sk svaz R ma ov zve v echny srde n na V stavu v p s E 4 it j Fig 28 example of the temperature embedded to WEB site Examples to the simple scripts for PHP and ASP processing temperature from the TME is available for download here http www papouch com en website mainmenu how to web thermometer There is a brief comment and function description with those examples HTTP GET
47. rature acguisition method 1 Internal website When the thermometer s IP address is set in an Internet browser a website is brought up displaying the actual temperature value and the set temperature limits A Czech or English language version of this website can be chosen within the settings The temperature value can be shown in degrees Celsius or Fahrenheit Either a graphical display resembling a mercury thermometer can be selected or a plain text Cf also page 29 2 XML file At http IP address of thermometer fresh xml the file in XML format contains the actual temperature value the name of the measurement location and the temperature limits Cf also page 33 3 Inserting the temperature value into a website using a script HTTP GET Thermometer TME enables a periodic call for a script e g PHP or ASP on a given address for example a WEB server Cf also page 35 Optimised for Internet Explorer 7 0 Mozilla Firefox 3 0 Opera 9 6 Google Chrome 1 0 iPhone and Android The browser s JavaScript support must be enabled Page 6 www papouch com Papouch s r o TME 4 SNMP protocol According to the settings TME sends out SNMP traps if the temperature value is outside of the set limits Regular transmission of a trap with the actual temperature value is also possible Cf also page 41 5 E mail According to the settings the thermometer sends E mails with information if the temperature value goes outsid
48. re aes 42 MIB table cooker tapetu cede bee 42 Automatic traps i c een 43 Sending C MAIIS cccceecceeeeeeeeeeeeeeeeeeeeeeeeees 45 MODBUS Protocol 5o feste ia donata dedasatudccdc ss 45 pA E t dap c E o dn 46 What needs to be set for my thermometer to work in the network sssssssss 46 How do get TME s IP address 46 Indication 5 AAA ADA AL CUN 47 Hard ToSBL usa etait e kud ebore B e PED expan 48 technical parameters sssusss 49 Common parameters sssusss 49 TMEVSISIOEo auc otoc bue oue Deo ec cero Pee e recae 49 TME POE verison sss 50 Default Ethernet settings 50 Page 3 TME Papouch s r o BASIC INFORMATION Description TME is a simple temperature sensor with Ethernet interface It measures temperatures ranging from 55 C to 125 C Measured values can be read in several ways including internal WEB pages The communication is realized via various TCP IP protocols Thanks to this it is possible to choose a method suitable for particular application The temperature is sent in a simple ASCII format directly in degrees Celsius there is no need of any additional conversion It also enables communication with SNMP protocol UDP or sending an e mail in case any of the pre set limits is exceeded You can easily embed the temperature from TME to your WEB site using http GET Measure
49. teel rod Normalized diameter 5 7 mm and length 60 mm DOOR ILL LLL LLL LLL ALAS LLL LLL LLL D 1 2 Se ae ee Jm Fig 4 Standard sensor make Cable type e Silicon cable diameter 4 3 mm Temperature resistivity 60 to 200 C Blue color Cable length e 3 m standard e Maximum 20 meters Mounting e Without a holder standard e With a DIN rail mount Fig 5 TME on the DIN rail Power TME version e 5V Power Supply wall plug adaptor included E 19079413 Fig 6 External power version TME WWW papouch com Page 11 TME Papouch s r o Power TME PoE version e Power directly from ethernet network PoE standard IEEE802 3af external PSU can be used to power TME PoE Fig 7 PoE powered version TME PoE Please do not hesitate to contact us if you have specific requirements for the TME module s workmanship and functionality Package Contents e TME Thermometer with sensor on 3 m cable e 5 V PSU wall plug adaptor TME version only e 1 m direct PATCH cable CD containing software and documentation Accessories e Power supply cable 2 m long with a 3 8 x 1 3 mm connector The other end is open with conductors to be wired into the power source e A power supply cable from a USB 2 0 port Page 12 www papouch com Papouch s r o TME CONNECTION Default TME s IP address is 192 168 1 254 1 Connect the TME to the included power supply or to
50. terprises 1315 78 1 1 0 notification received from 127 0 0 1 at 21 4 2005 12 57 28 4 2 enterprises 1315 78 1 1 0 notification received from 1234cdef 000cH cb9e56 at 21 4 2005 12 57 28 3 Specific trap 1 trap v1 received from 192 168 1 45 at 21 4 2005 12 58 19 C Time stamp 0 days O0h Qm 20s 94th B Agent address 192 168 1 45 Port 162 Transport IP UDP Protocol SNMP 1 Trap Manager address 192 168 1 42 Port 162 Transport IP UDP Community public 3 SNMPv1 agent address 192 168 1 45 Lu Enterprise traps Bindings 4 Binding 1 int temperature t 0 int32 218 Binding 2 string temperature LO octets 21 8 2B 32 31 2E 38 hex Binding 3 device name LO octets TME 54 4D 45 hex Binding 4 waming_t 0 octets lower limit of 026 0 6C 6F 77 65 72 20 6C 69 6D 69 74 20 6F 66 20 2B 30 32 36 2E 30 hex B SNMP notifications received Fig 33 Trap 1 the temperature value occurs below the lower limit igi xi i me Auto scroll Insert on top Pause a H A 1 enterprises 1315 78 1 1 0 notification received from 127 0 0 1 at 21 4 2005 12 57 28 2 enterprises 1315 78 1 1 0 notification received from 1234cdef 000cf1cb9e56 at 21 4 2005 12 57 28 3 Specific trap 1 trap v1 received from 192 168 1 45 at 21 4 2005 12 58 13 4 4 Specific trap 1 trap v1 received from 192 168 1 45 at 21 4 2005 12