1. ne A SR ZT RA Cee res 1 zen e 7 bag Frhr u EBC80 EBC50 64 1 2 gt 95 1 4 A 7 kk N N oe N N O e eS SE eh Y Y 2 gu i E 4 SSB t A LI 8 lt RIA E EVEREST gt en Ser DJ EBC65 EBC95 SS 10 _ REFRIGERATION VEREST Critical Information CONDENSER COIL MAINTENANCE Failure to maintain a clean condenser coil will eventually result in compressor failure and product loss Mechanical failures due to a lack of or improper maintenance are not covered under warranty Keeping the condenser coil clean will maximize energy savings Cleaning of the condenser coil is part of regular maintenance and is not covered under warranty CONDENSER COIL CLEANING PROCEDURE Please use the following steps to clean the condenser coil If you have any questions regarding this procedure please call the Everest customer service department at 800 444 6285 1 Unplug the unit from the wall 2 Remove the front right bottom grill when facing the unit It is attached with Philips head screws 3 Clean the condenser coil using a vacuum or brush The fins of the condenser coil should only be cleaned and swept in the direction of the fins which is up and down Be careful not to bend the fins 4 In some instances the condenser coil may require professional cleaning due to a buildup of grease and dust In this case contact a local refrigeration company to take ca
2. 7 REFRIGERATION REFRIGERATION EVEREST www EVERESTref com Owner s Manual for models Horizontal Bottle Coolers EBC37 EBC50 EBC65 EBC80 EBC95 A Step Above the Standard Thank you for selecting an EVEREST product BADEN 150 9001 Safety Notices WARNING When using your appliance always follo the following When installing the unit be careful that the electrical cord is not under the unit or pressed against the wall This could cause a damage to the cord i To prevent electrical shock please do not plug or unplug the cord with wet hands Install the unit on a hard and level surface Please do not store temperature sensitive items in the unit such as medical or science research related materials REFRIGERATION VEREST Before starting the unit for the first time make sure the unit is free from all packaging Packaging left on the unit during operation may cause a fire hazard Before cleaning or maintaining the unit please unplug it Do not use any flammable cleaning products on or around the unit Please do not hang or climb on the unit as this may cause the unit to fall If you suspect a refrigerant leak unplug the unit and immediately contact an authorized service technician Safety Notices WARNING Read and follow all safety notices in this ir These notices provide helpful safety and effi information Failure to do so may
3. change without notice Depth does not include bottle cap opener with integrated cap receptacle BE 8 O IN Temperature Setting FEN LUEREST Temperature Setting Range Setting Range REF F REFRIGERATION VEREST Product Drawings 36 3 4 3 4 0 D Bi _ 29 m 2 1 4 14 1 4 12 1 2 2 aie T Shaped PVC er a g 5 TE A Drain Fittings w a Moveable Plu g 2 N CD co CD k 1 09 ES SS SS SS zle 5 A gt E A Lo y y y TJ CETTE 3 26 3 4 2 1 4 PA A pegi voy SIDE VIEW EBC37 lt 80 1 2 gt p 49 1 2 u A A al A amp amp a a Y gt o gt gt w H a ee ZZ 42 Y 2 p CD En
4. parts and or labor warranty claims made on units sold or used outside of the United States ADDITIONAL TWO 2 YEAR COMPRESSOR WARRANTY In addition to the warranty set forth above EVEREST warrants the hermetically sealed compressor for an additional two 2 years not to exceed sixty 60 months from the date of shipment from EVEREST provided upon receipt of the compressor manufacturer examination shows the sealed compressor to be defective This compressor warranty does not apply to shipping or labor costs or any other parts of the unit whether electrical or mechanical These warranties are exclusive and in lieu of all other warranties expressed or implied and all other obligations or liabilities on our part and we neither assume nor authorize any other person to assume for us any other obligation or liability in connection with the sale of said refrigeration units or any part thereof _ 12 _ REFRIGERATION PERA REFRIGERATION PERA REFRIGERATION VEREST A Step Above the Standard 201 W Artesia Blvd Compton CA 90220 Tel 310 323 6586 800 444 6285 Fax 310 323 7524 310 761 1127 Visit our website at www EVERES Tref com
5. cturer which ever occurs first is limited to the repair or replacement including labor charges of defective parts or assemblies The labor warranty shall include standard straight time labor charges only and reasonable travel time as determined by EVEREST WARRANTY CLAIMS All warranty claims for labor or parts must be made directly through EVEREST All claims shall include unit model number cabinet serial number proof of new product purchase installation date and all pertinent information related to the alleged defect For compressor warranty claims the compressor tag shall be returned to EVEREST with the above listed information WARRANTY EXCLUSIONS EVEREST s sole obligation under this warranty is limited to either the repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty A NON WARRANTY PARTS EVEREST excludes specific parts exposed to normal wear and tear These parts include but are not limited to lamps gaskets casters shelves and shelf clips pans bin and pan dividers and airflow guards B INDIRECT OR CONSEQUENTIAL DAMAGE EVEREST does not warrant economic loss profit loss or special indirect or consequential damages including without limitation losses or damages arising from food or product spoilage claims caused by refrigeration failure C IMPROPER USAGE EVEREST i
6. lead to se or damage to the unit To minimize shock and fire hazards be sure not to overload the outlet into which the unit is plugged into A dedicated circuit of sufficient amperage is required To prevent electrical shock and malfunction do not spray the unit with water When it is time to salvage the unit make sure to remove the the doors to prevent the risk of children or animals getting trapped inside the unit REFRIGERATION VEREST To prevent damage to the electrical components have the unit plugged in directly to its own circuit EVEREST is not responsible for any damage caused by improper electrical connections resulting from electrical power failure use of extension cords amp surge protectors and any voltage drops to the unit Clean the pronges of the electrical plug with a soft cloth or brush before plugging it into an electrical receptacle to prevent fire hazard Wr To prevent electrical shock and damage to the electrical cord please hold the plug head when plugging and unplugging the unit To avoid personal injuries from broken glass please do not place glass items in the freezer After unplugging the unit please wait at least 6 minutes before re plugging itin Failure to do so could cause extensive damage to the compressor If the unit will not be used for an extended period of time please unplug it from the outlet The refrigerator c
7. ment The condenser coil should be cleaned in the direction of the fins top to bottom not side to side Be careful not to bend the fins REFRIGERATION VEREST Trouble Shooting Please check the following before requesting service Condensing unit leiser a Ensure the electrical cord has been connected Ensure the unit is turned on Cabinet does not Check the door gaskets for proper seal maintain proper Check to see if the temp control setting is too temperature high then adjust as necessary Avoid installing the unit next to heat generating equipment and direct sunlight Avoid storing hot contents Ensure the doors are fully closed Refrigerated compartment is too Adjust the temperature control to a warmer Check for loose parts Check for tubing rattle Check for a bent fan blade Check for damaged fan motor bearings Ensure the unit is stable Ensure the cabinet is level Condensation on the Condensation on the exterior surface of the exterior surface unit is perfectly normal during periods of high humidity Check door alignment and gaskets for proper seal Noisy operation Sound of water This is the sound of the refrigerant circulating dripping during the compressor rest period and it is normal Exterior walls are warm Heaters have been placed around the door Openings to prevent condensation buildup This is normal Condensation on the ome a Condensation ca
8. n occur during hot and humid interior weather with frequent or prolonged door opening This is normal b The doors might not be closed properly REFRIGERATION VEREST 4 9 i 1 gt B A A Insert the ratchet A into the Ratchet lock Assem bly hole B of the door handle Step 2 A Push the ratchet A all Insert the lock C into the the way in until it is fully ratchet A until the lock C attached to the surface hits the door handle of the product Then turn the key to lock it Shelves Installation Step 1 E IN Place the bottom shelves on Fit the spring into the partition the cabinet floor shelf marked A Insert the partition shelf at a 45 degree angle so that the spring fits into the hole located at the back wall as shown in Picture 1 Push the shelf towards the back wall and align the other end of the shelf in place so that it firmly stands vertically as shown in Picture 2 Picture 1 Picture 2 _ 7 _ IN REFRIGERATION VEREST Capacity Cu Ft Cu Ft Specifications of Bin Dividers of Floor Shelves Oo EEE compresor m m Temp Range Cate ht a f as f o Dimensions Wx D x H inches 36 3 4 x 26 3 4 x 33 3 4 49 1 2 x 26 3 4 x 33 3 4 64 1 2 x 26 3 4 x 33 3 4 3 omweso a O Temp Rangel ctei Dimensions Wx D x Hinches 80 1 2x 26 3 4 x 33 3 4 95 1 2x26 3 4 x 33 3 4 ae a Specifications subject to
9. ompartment temperature should be set at 32F 42 F See page 9 Setting the temperature out of the recommended lt f ranges will void the unit s warranty REFRIGERATION VEREST Do not use the electrical cord or plug if they are damaged in any way Avoid installing the unit where it could be exposed to water or moisture Please do not attempt to remove or repair any components unless you are an authorized i El service technician Do not put your hands under the unit when moving it You could be injured by sharp edges protruding parts crushing etc Installation Guide Install the unit on a hard and level surface or the unit could produce undesired noises Indoor Use Only Outdoor use may cause a decrease in performance and significant damage to the Do not build an enclosure or cabinet around the unit Restricting the airflow around the unit s condenser area will cause the compressor to work harder which can result in compressor failure and the unit not being able to maintain the desired temperature REFRIGERATION VEREST The unit should be at least 2 away from the wall Dusty and High Humidity Areas Dusty environments will cause the condenser coil to prematurely clog which will require it to be cleaned more often High humidy environments could cause the unit to rust Select a location away from other heat and moisture generating equipment such as st
10. oves ovens dish washers etc High ambient temperatures cause the compressor to work harder which can result in compressor failure and the unit not being able to maintain the desired temperature REFRIGERATION Maintenance Guide VEREST Shlef Cleaning Periodically remove the shelves from the unit and clean them with mild soap and warm water Do not use the following products when cleaning Clean the exterior of the product with mild soap and warm water Never use steel wool strong acids abrasive cleaners or degreasers Acidic products and products containing vinegar must be stored in sealed containers to prevent acid damage to the interior of the unit and the evaporator coil Rust resulting from the lack of or improper maintenance will not be covered under warranty Interior Cleaning Clean the interior surface of the unit with mild soap and warm water Do not let water accumulate inside the unit To prevent water damage wipe the interior ofthe unit with a dry cloth as needed Do not use abrasive cleaners concentrated detergents ble ches cleaning waxes solvents or polishes to clean the interior Condenser Coil Cleaning Poor condensing unit performance is caused by heavy dust build up on the condenser coil The condenser coil should be cleaned monthly Shine a flashlight through the condenser coil to check for dirt between the fins Clean the outside of the condenser with a soft brush or a vacuum with a brush attach
11. re of this for you 5 Ensure no tools or parts have been left in the condensing unit area 6 Replace the front right bottom grill The warranty card below must be submitted to Everest within thirty 30 days of purchase WARRANTY REGISTRATION CARD Business Name Telephone Address City Place of Purchase _____ Date Purchased Datelnstalled Model No Cabinet Serial No 3 YEAR PARTS and LABOR WARRANTY Applicable to units purchased after July 1 2014 5 YEAR COMPRESSOR WARRANTY Name of Business Owner ees Date Signature of Business Owner REFRIGERATION VEREST Warranty Certificate EVEREST LIMITED WARRANTY EVEREST warrants to the original purchaser of every new EVEREST unit the cabinet and all parts thereof to be free from defects in material or workmanship under normal and proper use and maintenance service as specified by EVEREST and upon proper installation and start up in accordance with the instruction packet supplied with each unit Our obligation under this warranty is limited to a period of three 3 years from the date of original installation or thirty six 36 months after shipment date from EVEREST which ever occurs first This is applicable to units purchased after July 1 2014 Any part covered under this warranty that is determined by EVEREST to have been defective within three 3 years of original installation or thirty six 36 months after shipment date from the manufa
12. s not responsible for parts or labor coverage for component failure and or other damages resulting from improper usage installation or failure to clean and or maintain product as set forth in the user s manual provided with this unit All EVEREST products are designed for commercial usage not for residential use Therefore the warranty will not be honored if product is installed in a residential house D WARRANTY IS NOT TRANSFERABLE Warranty is limited to only the original purchaser user to whom delivered It is not transferable E ALTERATION NEGLECT MISUSE ABUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD EVEREST is not responsible for malfunctions due to alteration neglect misuse abuse accident damage during transit or installation fire flood storm and or other acts of God And EVEREST is not responsible for any improper electrical connections resulting from electrical power failure the use of extension cords and low voltage or voltage drops to the unit F UNAUTHORIZED MODIFICATION EVEREST is not responsible for the repair or replacement of failed or damaged components resulting from unauthorized modifications to units or the use of non standard parts without prior written approval from EVEREST G RESIDENTIAL NON COMMERCIAL USE This warranty does not apply to a unit installed in a residential setting This unit is for commercial use only H OUTSIDE THE U S This warranty does not apply to any
Download Pdf Manuals
Related Search
Related Contents
REF-METER-OCTA 4679462 - Refco Manufacturing Ltd. Manual de instrucciones Hydroartica 27 ScoutPro ACS - BIOTRONIK USA Samsung H1255A Наръчник за потребителя C O N T E N T S - MSC Software Corporation SNC-CH135/CH140/CH240 Mod: MIF-25 User`s Manual AOSafety AO 7 Star User's Manual manual del usuario - Formando Formadores Copyright © All rights reserved.