1. Inneh llsf rteckning Parts of the system e The system 8 The components P 2 Effecta AB V stra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se Warranty Effecta Products are guaranteed to be free of defects in materials and workmanship for two years from the installation date This applies to wear parts such as seal the main body of the boiler cera mics and electrical components This guarantee also covers original spare parts Any faulty products will be replaced or repaired at the discrimination of the retailer or Effecta If a faulty product is replaced Effecta 1s entitled to replace it with a new or reconditioned product of the same or a simi lar type Effecta gives a 5 year warranty on the remaining components See the attached warranty document If you have a complaint you must contact Effecta before starting any servicing work You must submit your complaint without delay You must always state the type of product the date of purchase and the serial number Otherwise the heating and plumbing industry s current regulations apply in the case of complaints Guarantee terms The guarantee is valid on condition that e The boiler and the heating system have been installed in accordance with the installation instructions and in a professional manner e The location where the product is installed is suitable for the purpose e The pellet burner used is recommended by Effecta The guaran
2. from the pump pressure 2 Heating phase When the boi ler temperature exceeds 78degrees the thermovalve be gins to open and mixes cold water from the tank Normally the temperature of the return water to the boiler is about 70degrees and the hot water from the boiler about 80 85degrees 3 Final part When the accumula tor is getting almost fully charged the Laddomat thanks to the unique thermal valve charges the accu mulator completely by closing the bypass opening 4 Self circulation In the event of a power failure the Laddomat im mediatly starts charging the accu mulator by self circulation The same happens if the pump breaks down 6 Reverse crculaionvave SOS Cs spring Co Filing sie 12 Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se PEJOIJAD PICKS CICA 3 J9AQYaq YOO JUL p IEpuejs uo Je ENP iSdO Charging Expansion 1147 9 Cold domestic water 22mmeu Thermometers V7 6 Connect tons 22mmeu a Water ftom solar panels Immo s Sensor solar 12 Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se 13 14 THE CONTROL PANEL oz controller Mancoverstr m Overhetining 6 LCD Display Shows tamperatues oxygen value effectivity etc etc Effecta AB
3. draft stabiliser too close to the boiler you might have smoke coming out of the stabiliser L OBS T nk p att alltid isolera r rledningar 1 systemet Effecta AB Vastra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effecta se 7 Systemet Wood gasification boiler Safety valve 1 5bars Laddomat valve Electrical heater Valve combination Shunt valve with automatic motor Outlet frfom safety valve Suitable connection for an open expansion vessel Suitable placement for air escape vent Suitable connection for pressure vessel ap Return water from the radiators BER Domestic cold water inlet Effecta AB V stra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se Effecta AB Vastra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effecta se l0 Effecta AB Vastra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effecta se Placement of components Component Component Control panel Ceramics ERE Return from tank drain cock Convection area Flue gas fan Smoke pipe elbow 500x150x150 Technical data Le Effecta AB Vastra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effectase ll Function Laddomat 21 7 mm mm UN I Start Before the boiler tem perature has reached 78degrees the thermovalve 1s closed and the valve for self cirkulation is closed
4. low output of harmful gases as possible Normally you don t need to change the settings when you are burning different kinds of wood with different moisture content The system Effecta Lambda should be connected to at least 15001 of accumulation volume At installation there should always be a Laddomat valve connected A woodfired boiler that is connected to one or more buffertanks will have a lot of advantages The grate can always be fully loaded The user will have a long time between the warmups Prolonged lifespan The boiler is always used on maximum prestanda Efficency and envirinmental assets will be on top You should always strive after a dimension of the accumulationsystem so that you don t need to make more than one warmup a day When you startup a new fire the fan will start to provide combustion air and to prevent smoke from coming out of the fireside When the boiler has reached a temperature of 78degrees the charging of the tank starts The laddomat valve care for the statification in the tanks When the accumulators are heated the pump and fan stops The warm water in the tanks then heats the radiators in the house and the domestic water through a coil Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 infoG effecta se To the installer It s now time for the installation of the boiler Try to follow the examples we are describing for a safe installation After the installation be careful
5. under remove dust and other objects Control the seals in the doors they must not leak Remove the lambda sond and clean it from ash and soot 18 Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se Trouble shooting Possible faults E from the grate at start The fan is not running Press Start e from closed doors Seals leaky Adjust doors replace seals The fan doesn t start Tar 1n the convetion area None or little heat is transfer red to the accumulator The boiler gives less effect and 1s hard to use The laddomat valve is bang ing or making strange noices poor flue through the system The pressure is decreasing in the system Faulty control panel Overheating protection released Too much soot in the grate Lambda sond dirty Dampers faulty Air in the system Poor wood Moisty wood to little draft through the chimney The boiler needs to be cleaned Air in the system To low pressure in the system You have a leak in the system Water have vaporised from the open expansion vessel Wrong pre pressure in the pressure vessel Contact Effecta Press the reset pin under the hat Clean grate Clean lambda sond Contact Effecta Try to deair the system Switch to better wood or split it finer Try wood with less moist Clean the boiler Try to deair the system Increase pressure Check for the leak Fill the system Adjust pressur
6. Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se Electrical installation 230V Y SOUSONI1dd04 E N L S J 7 T Traco 2 1 amp 12 volt 12 volt 7 ee ee u LO bab eel ri pel poe M MEM Eurappauaaan i I Yellow L1 White NENNEN Grey Green Black a E XN E HUE E moa i Fi E 2 5 2 s EN e NN Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 infoG effecta se 15 Environment The surroundings When you re using a wood gasification boiler it s important to fire in a way that s not harmful for the environment or your neighbours Take considerations in the following things The fuel Effecta Lambda designed to be used with wood logs The kind of tree species has no bigger importance other than that birch beech and oak have a higher efficency value than conifer This means that the ac cumulator is heated faster with broad leaved trees than with coniferous trees Birch beech and oak also have a slightly higher density than conifer wich lead up to a bit more com pressed pile of wood in the grate which leads to a smoother gasification of the wood and a steadier combustion When making a fire big and small logs should be mixed with the largest on top in the grate You shouldn t use only fine cloven wood or the opposite only big logs Using only fine cloven wood can lead to a fire with h
7. e Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 infoG effecta se 19 P mm En TN F rs kran om verensst mmelse Effecta Pannan AB effecta Vastra ragdalsvagen 21 43496 Kungsbacka Forsakran avser under eget ansvar produkten Effecta Woody Vedpanna Nummer 02 756697 02 Direktiv 89 336 EEG med tillaggen 92 31 EEG 93 68 EEG EMC 73 23 EEG med till gget 93 68 EEG LVD 97 23 EC PED Harmoniserande standarder SS EN 60204 1 Elektrisk utrustning for industrimaskiner Del 1 Allm nna fordringar kopplat till maskin och LVD SS EN 50081 2 F r emission industri EMC standard SS EN 50082 2 F r immunitet industri EMC standard Kungsbacka 2004 12 12 Erik Andersson C 4 L Effecta Pannan AB J een LLLA O 20 Effecta AB V stra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se
8. en 21 434 96 Kungsbacka 0300 22320 infoG effecta se 17 Sooting To get the best performance from your Effecta boiler it is important to clean it on regular basis In winter time it s appropriate to clean it once a week in summer once a month e Start by removing the stainless stick which lies on top of the ceramics Remove bits of logs and coal through the opening be tween the ceramics The walls in the grate is usually covered with a thin layer of tar There is no need to remove this Then remove the rear top plate and the ash hatch Remove the 7 turbulators and use the appurtenant brush to clean the tubes Then open the lower front door pull out the afterburner and empty it from ash This should be done every third warm up to get the most out your boiler Then scrape out the dirt in the space beneath the ceramics When cleaning the boiler you might also clean the fan Remove the wing nuts at the fan and pull the fan out from the boiler Ls Clean the wheel from dust and soot If not properly cleaned the boiler will detoriate add burn with lower efficency Cleaning of the fan should normally be done 3 4 times year Annual Service Every year you should do a more thorough control of the boiler a good time to do this is before winter when the boiler will be used more frequently Start by controlling the combustion zone and ceramics In the interspace between the ceramics is metall plate with holes seen from
9. he chimney 1s 70 80degrees If the chimney is tall and wide it may result in to much draft which can lead to too much gasification and too much fire in the grate This can be prevented by installing a draft stabiliser Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se 2 Components Laddomat 21 A Laddomat valve should always be mounted between boiler and tank It s described further on page 10 Automatic Shunt It s recomended to use an automatic shunt valve to control the flue in the radiator circuit It feels the temperature in a special place in the house and regulates the temperature in the radiator circuit flue Using an automatic shunt will significantly reduce the amount of wood needed during a year and your indoor climate comfort will also improve Expansion Vessel The expansion vessel normally is tested for 6bars Highest working temperature is 99degreees The vessel has a preepressure of 2 5bar The volume should be approx 10 of the total volume of the sys tem An open vessel should have a volume of 5 of the total Safety Valve The safety valve will release when pressure exseeds 1 5bars When it opens water will drip out of it and the pressure goes down Remem ber that the system is designed for a maximum pressure of 1 5bars and shall under no circumstanes be under higher pressure Shuntvalve The shunt valve is mounted on the radiator circuit and it s designed to
10. he system The power supply should always be switched ON Put a handful of fine cloven wood in the bottom of the grate Then put quite a lot of paper and put on top of the pile Push the button Start and then ignite All hatches should be closed except the grate door which can be opened a little bit You might have to try some small changes Le closing the grate door etc to get the best result When the fire has started and it s been burning for a while a glow should appeare in the bottom Now you can fill the grate with wood Start by putting smaller bits in the bottom and increasing the size further up in the grate The better packed the logs are the higher the effiency and less emmisions you will get When it has been burning for about 15 minitues the flames should fill up the afterburner that you can see in the inspection panel in the lower ash door The boiler makes best use if it s left alone withou in terfernce If you open the grate door during a fire there 1s risk for to much gasification which leads to deterioation of the function If you are using very dry wood and have a powerful draft you might hear a puffing sound from the dampers This doesn t deteriorate the combustion but to avoid this you can install a draft stabiliser NOTE On the occasion of second inlay there is a risk of smoke pooring out of the grate door Therefore open the door cautiously to evacuate gas and smoke in the grate Effecta AB Vastra Ragdalsvag
11. igher effect than the boiler is designed for The consequenses can be shortened lifespan of wear parts such as ceramics fan etc Using only bigger logs might lead to a fire with low effect with low flue gas temparature as aftermath This might lead up to damages on the chimney if you get condensation in it Never make a bonfire with stuff that is harmful to the environment such as impregnated wood domestic waste plastics or rubber etc storage of the fuel To ensure that the Effecta Lambda works in best possible way the quality of the fuel must be good It s important that the wood has the rigtht moisture it should be somewhere around 15 20 The logs should be split into 5 15cm big bits and the length should be 45 50cm Never use logs longer than 51 52cm this will make the logs jam in the grate Try to use the sun and wind when storing the wood If it s to much dampness in the logs the efficency of the boiler will drop Cannibalisation It is many years to come before your Effecta boiler 1s spent but we ask you to follow the rules and regu lation currently valid at the time for cannibalisation of your boiler l6 Effecta AB Vastra Ragdalsvagen 21 434 96 Kungsbacka 0300 22320 info effecta se The control The Effecta Lambda s combustion is controlled by a lambda sond placed in the smoke pipe Start of a fire cycle is done by pressing the button Start the dampers is than placed in a position to give the right amoun
12. mix the accumulatorwater and the return water from the radiator to get the right temperature indoor If mounting an automatic shunt valve read it s instructions L 6 Effecta AB V stra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effecta se Valve Combination The valve combination is mounted on the domestic water circuit It s purpose is to mix the hot water with cold before it reaches the water taps This is to avoid burns and to keep the taps and seals from be ing destroyed by to hot water Piping Normally copper is used for installing these systems Piping between boiler and accumulators should not be less 28mm If the piping is longer than 6 meters to the first tank it s recomended to use 35mm The Accumulator Tank Effecta Lambda must always be connected to some sort of accumu lator tank where the energy is stored and where the domestic water and the warm water to the radiators is taken The accumulator is described more thorough on page 13 The Draft Stabiliser If you have a tall and wide chimney it s possible that you have to install a draft stabiliser You might notice that you have an irregular combustion puffing sounds from the boiler This happens when the chimney sucks too much air through the boiler The placement of the draft stabiliser in the chimney should be approx one meter above the connection to the boiler This is because you have an overpres sure from the fan and if you place the
13. t of air to the up start When the start is done and the flue gas temperature has reached a temperature of 100degrees a measur ment of the gases starts The control strive after a preprogrammed value 13 of co2 and moves the dampers to achieve this The lambda sond leaves a signal every second 0 5 The button Stopp interrupts the fire and stops the fan and pump The button Menu gives you the opp ortunity to browse the menues The menues Calibration lambda sond This should be done prior to the first fire and there can be no fire in the grate when doing this Tuning of lambda value This is done by pressing A stopp B This can be changed if you have big differenses in wood qualites e Sooting After some time of using a recommandation to soot the boiler will appear in the display Then clean the boiler and reset the control by pressing yes in the menu Making a fire Now it s time to make a fire Remember that during the first fire the boiler can appear to be slow and it can be a bit hard to get a good combustion This 1s because alla the metalsheets in the boiler are clean and cooled by the boilerwater Also the ceramics have some moiste in it which needs to dry out This uses extra energy and makes the fire a little more slow During the first warm ups there are also lots of air in the system and this might lead to some strange noices in the pipings and the boiler This will dissapear after a few warm ups of t
14. tee does not cover e The overall functioning of the heating system costs incurred as a result of the heating system being out of operation or the cost of the temporary replacement of products e Damage or injury caused by negligence during the installation or by operating the boiler in a way which conflicts with the installation and user instructions e Damage caused by abnormal wear incorrect operation and maintenance Damage caused by the boiler being positioned in an unsuitable location e Damage caused by vermin Date LEE EE Effecta AB Vastra R gdalsv gen 21 434 96 Kungsbacka 0300 22320 info effecta se 3 A In General Effecta Lambda is a woodfired boiler with a suction fan The boiler should be connected to one or more accumulators which are heated via a Laddomat valve Warm water is taken from the top of the boiler and is fed to the top of the tank The return water is taken from the bottom of the tank and is fed to the bottom of the boiler Domestic water To get domestic water the tank needs to be equiped with a coil The tenperature of the water is regu lated with a mixing valve The amount of warmwater is dependent upon the temperature and size of the tank Combustion On the front of the boiler is two airinlets with dampers which are controlled by two motors The mo tors gets signals from the lambdacontrol depending on the amount of oxygen in the fluegases The sys tem is designed to get as
15. to educate the end user of the boiler how the system is used and maintained this is to avoid unnecessary stops an problems Location The boiler shall be placed on a firm foundation try also to place the boiler as horizontally as possible this to avoid airpockets in the boiler Keep in mind the laws and regulations regarding distances to com bustible materials The boiler room The boiler room shall be constructed according to current laws and regulation if uncertain regarding this contact concerned authority You need good ventilation in the boiler room to get the best performance of the Woody Lambda The accumulator It s important that the accumulators are well isolated this is to get as small heatlosses as possible To get a good comfort regarding the number of times you have to be in boiler room you need at least 15001 of accumulation volume The chimney The chimney should have a diameter of at least 150mm if you have a chimney with less diameter Effecta should be consulted before installation The draft in the chimney should at low temperature be approx 15 pa It s important that the chimney is tested and approved by concerned authority before a new boiler is installed If the draft is to hefty a draft stabilator might be needed If you have a tall chimney and a flue gas temperature below 170degrees there is a risk of condensation which in the long run can be harmful to the chimney Adequate temperature 1 metre from the vent of t