Home

JUMP&GO - InvertersRus

image

Contents

1. 3 Insert the blue connector firmly into the Jump Start port If below 32 F 0 C please allow a few minutes before starting the vehicle 4 Start the vehicle Once started unplug the blue connector from the JUMP amp GO then remove the battery clamps CAUTION Repeated consecutive starting attempts or continuous cranking of vehicle starter can cause overheating or damage to the JUMP amp GO If vehicle does not start with initial attempt allow 30 60 seconds between attempts If JUMP amp GO becomes warm to the touch disconnect JUMP amp GO from the cables and allow to cool before reattempting to start the vehicle FLASHLIGHT FUNCTION Flashlight LED Illumination Press and hold the power button for 3 seconds to initiate the flashlight Once the flashlight is on a press and release of the power button will change to an alternate mode of operation in the order listed below To shut the flashlight off you must cycle thru the selections FLASHLIGHT gt BEACON gt STROBE gt SOS gt OFF FAQ S amp SPECIFICATIONS How to turn off the JUMP amp GO This appliance will power off automatically when no load or charging is detected How many times can the JUMP amp GO charge my mobile phone Approximately 7 times depending on phone ro How long will the JUMP amp GO take to fully charge my mobile phone 1 2 hours depending on phone How many times can a fully charged JUMP amp GO start the vehicle 10 20 times depending
2. AR 72756 Please allow 3 weeks turnaround time 7 WARRANTY INFORMATION IMPORTANT Whistler will not assume responsibility for loss or damage incurred in shipping Therefore please ship your unit insured with return receipt requested CODs will not be accepted 2 Include with your unit the following information clearly printed e Your name and physical street address for shipping no PO Boxes a daytime telephone number and an email address if applicable e Adetailed description of the problem e g device will not power ON e A copy of your dated proof of purchase or bill of sale 3 Be certain your unit is returned with its serial number Units without serial numbers are not covered under warranty IMPORTANT To validate that your unit is within the warranty period make sure you keep a copy of your dated proof of purchase For warranty verification purposes a copy of your dated store receipt must accompany any Whistler product sent in for warranty work Service Out Of Warranty Units will be repaired at out of warranty service rates when e The unit s original warranty has expired e A dated proof of purchase is not supplied e The unit has been returned without its serial number e The unit has been misused abused modified installed improperly or had its housing removed The minimum out of warranty service fee for your Whistler Jump amp Go is 50 00 U S If you require out of warranty service plea
3. JUMP amp GO Portable Jump Start amp Power Supply OWNER S MANUAL AVUN GO PORTABLE JUMPSTART amp R eo Pa WHISTLER WHISTLER PRODUCT LAYOUT Welcome Thank you for choosing a Whistler product We are dedicated to providing products that represent both quality and value Please read the user manual carefully before using this product If you have additional questions please visit the FAQ page on our website at www whistlergroup com or call toll free 800 531 0004 8am to 5pm CT Monday through Friday to speak to a Customer Service Representative Packing List e Jump amp Go e Protective Cover e Jump Start Cables e 12V DC Car Adapter e Home AC Adapter e Owner s Manual e Zipper Storage Case Feature Description Power a Button Flashlight LED Power 12V DC OUT 12V DC IN 2 1A USB Indicator Lights HIGH CURRENT Charging Port Output Port Jump Start Port CHARGING Charging the JUMP amp GO Plug the home adaptor into a 100 240V AC outlet of the proper plug type 2 Connect the other end of the home adaptor to the 12V DC IN Charging Port Or 1 Plug the car adaptor into the socket of the vehicle aux power 2 Connect the other end of the car adaptor to the 12V DC IN Charging Port Indicator Lights Press the power button to check the level of the JUMP amp GO battery Number of lights ON indicate percentage of charge available 1 20 2 40 3 60 4 80 5 100 NOTE e The Jump amp G
4. o should be charged before initial use e A minimum of 3 indicator lights must be illuminated before attempting to jump start a vehicle e The Jump amp Go will flash all 5 battery indicators simultaneously and provide an audible beep if the input charging voltage is too low or too high To properly charge your Jump amp Go with the Car Charger the DC input voltage should be 13 6 to 16 volts Vehicle charging system when vehicle engine is running When charging the LED indicator lights will sequentially flash The percentage of charge completed is indicated by the number of solid lights as charging progresses The JUMP amp GO is fully charged when all lights are solid 3 CHARGING JUMP STARTING NOTE A minimum of 3 indicator lights must be illuminated before attempting to jump start a vehicle For charging powering devices using USB port 1 Plug the USB cable of the device into the USB output port of the JUMP amp GO 2 Press the JUMP amp GO power button to initiate charging power to the attached e EZ WS Forj jump starting 12V vehicle Before attempting to start 12V vehicle please make sure at least 3 LED lights are illuminated on the JUMP amp GO when pressing the power button 2 Connect the Red clamp to the battery Positive and Black clamp to the battery Negative terminals making sure they have a good connection NOTE REVERSING THE CONNECTIONS MAY RESULT IN DAMAGE TO THE JUMP amp GO OR PERSONAL INJURY
5. on vehicle How long will the JUMP amp GO hold a charge The Jump amp Go will hold a charge over 1 year Why does the JUMP amp GO not indicate charging when using the vehicle power port adapter Start the vehicle to provide adequate voltage for charging How do dispose of the JUMP amp GO when it reaches end of service life The Jump amp Go contains a rechargeable Lithium Polymer LiPo battery pack This battery pack is self contained and is not replaceable For information on battery recycling or disposal call toll free 800 822 8837 POF PFN FO FO FO SPECIFICATIONS SIZE 130mm x 78mm x 24mm 5 1 x 3 0 x 0 9 WEIGHT lt 1 lb with silicone cover BATTERY CAPACITY 33300 mWh OUTPUT 5V 2 1A 12V HIGH CURRENT INPUT 12V lt 2A FULL CHARGING TIME 3 4 hours STARTING CURRENT 200A PEAK CURRENT 400A OPERATING STORAGE TEMP 20 C to 60 C 4 F to 140 F LIFETIME gt 1000 Cycles WARRANTY INFORMATION Consumer Warranty This Whistler product is warranted to the original purchaser for a period of one 1 year from the date of original purchase against all defects in materials and workmanship when purchased from an authorized Whistler retailer This limited warranty is void if the unit is abused misused modified installed improperly or if the housing and or serial numbers have been removed There are no express warranties covering this product other than those set forth in this warranty All express o
6. r implied warranties for this product are limited to one 1 year Whistler is not liable for damages arising from the use misuse or operation of this product including but not limited to loss of time inconvenience loss of use of your product or property damage caused by your product or its failure to work or any other incidental or consequential damages including personal injury DO NOT RETURN ITEM TO STORE WHERE PURCHASED FOR WARRANTY INFORMATION CONTACT WHISTLER CUSTOMER SERVICE AT 1 800 531 0004 Representatives are available to answer your questions Monday Friday from 8 00 a m to 5 00 p m CT Service Under Warranty During the warranty period defective units will be repaired or replaced with he same or a comparable model at Whistler s option without charge to the purchaser when returned prepaid with dated proof of purchase to the address below Units returned without dated proof of purchase will be considered out of warranty and therefore are not covered by the described Limited Warranty Refer to Service Out of Warranty section Due to the specialized equipment necessary for testing Whistler products there are no authorized service centers other than Whistler When returning a unit for service under warranty please follow these instructions 1 Ship the unit in the original carton or in a suitable sturdy equivalent fully insured with return receipt requested to Whistler Repair Dept 1412 South 1st St Rogers
7. se return your unit as outlined in the section Service Under Warranty along with a cashier s check or money order in the amount of 50 00 Payment may also be made by MasterCard VISA or American Express Personal checks are not accepted WARRANTY INFORMATION In the event repairs cannot be covered by the minimum service fee you will be contacted by a Whistler technical service specialist who will outline options available to you IMPORTANT When returning your unit for service be certain to include a daytime telephone number and an email address if applicable Customer Service If you have questions concerning the operation of your Whistler product or require service during or after the warranty period please call Customer Service at 1 800 531 0004 Representatives are available to answer your questions Monday Friday from 8 00 a m to 5 00 p m CT or visit the F A Q s at www whistlergroup com CORPORATE HEADQUARTERS 1716 SW Commerce Dr Ste 8 Bentonville AR 72712 Toll Free 800 531 0004 TEL 479 273 6012 FX 479 273 2927 www whistlergroup com CUSTOMER RETURN CENTER 1412 South 1st St Rogers AR 72756 Customer Service Tel 800 531 0004 Email info whistlergroup com P N 404001 09C14 2014 The Whistler Group Inc

Download Pdf Manuals

image

Related Search

Related Contents

Guida alla realizzazione quadri BT  Alpha Personal Priority Display User Manual - Alpha  Special Equipment  GÖRLIG    取扱説明書  NGS Flea Powered  GE EASM & EAMM Data Sheet  Montageanleitung Gas-Brennwerttherme  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file