Home
        JUMP&GO - InvertersRus
         Contents
1.  3  Insert the blue connector firmly into the Jump Start port   If below  32   F 0   C  please allow a few minutes before starting the vehicle    4  Start the vehicle  Once started  unplug the blue connector from the  JUMP amp GO  then remove the battery clamps     CAUTION  Repeated consecutive starting attempts or continuous cranking  of vehicle starter can cause overheating or damage to the JUMP amp GO  If  vehicle does not start with initial attempt  allow 30 60 seconds between  attempts  If JUMP amp GO becomes warm to the touch  disconnect JUMP amp GO  from the cables and allow to cool before reattempting to start the vehicle     FLASHLIGHT FUNCTION       Flashlight LED Illumination   Press and hold the power button for 3 seconds to initiate the flashlight   Once the flashlight is on  a press and release of the power button will  change to an alternate mode of operation in the order listed below  To  shut the flashlight off  you must cycle thru the selections        FLASHLIGHT    gt BEACON  gt STROBE  gt SOS    gt OFF    FAQ S  amp  SPECIFICATIONS         How to turn off the JUMP amp GO   This appliance will power off automatically when no load or charging  is detected     How many times can the JUMP amp GO charge my mobile phone   Approximately 7 times depending on phone    ro      How long will the JUMP amp GO take to fully charge my mobile phone   1 2 hours depending on phone      How many times can a fully charged JUMP amp GO start the vehicle   10 20 times depending 
2.  AR  72756    Please allow 3 weeks turnaround time     7    WARRANTY INFORMATION       IMPORTANT  Whistler will not assume responsibility for loss or damage  incurred in shipping  Therefore  please ship your unit insured with return  receipt requested  CODs will not be accepted     2  Include with your unit the following information  clearly printed   e Your name and physical street address for shipping  no PO Boxes    a daytime telephone number  and an email address  if applicable    e Adetailed description of the problem  e g   device will not power ON       e A copy of your dated proof of purchase or bill of sale     3  Be certain your unit is returned with its serial number  Units without  serial numbers are not covered under warranty     IMPORTANT  To validate that your unit is within the warranty period   make sure you keep a copy of your dated proof of purchase  For  warranty verification purposes  a copy of your dated store receipt must  accompany any Whistler product sent in for warranty work     Service Out Of Warranty  Units will be repaired at    out of warranty    service rates when   e The unit s original warranty has expired   e A dated proof of purchase is not supplied   e The unit has been returned without its serial number   e The unit has been misused  abused  modified  installed improperly   or had its housing removed     The minimum out of warranty service fee for your Whistler Jump  amp  Go   is  50 00  U S    If you require out of warranty service  plea
3. JUMP amp GO    Portable Jump Start   amp  Power Supply    OWNER   S MANUAL    AVUN  GO    PORTABLE JUMPSTART  amp  R  eo    Pa  WHISTLER       WHISTLER    PRODUCT LAYOUT       Welcome   Thank you for choosing a Whistler product  We are dedicated to providing  products that represent both quality and value  Please read the user manual  carefully before using this product  If you have additional questions  please  visit the FAQ page on our website at www whistlergroup com or call toll  free 800 531 0004  8am to 5pm CT  Monday through Friday to speak to a  Customer Service Representative     Packing List  e Jump  amp  Go  e Protective Cover  e Jump Start Cables  e 12V DC Car Adapter  e Home AC Adapter  e Owner s Manual    e Zipper Storage Case    Feature Description       Power a   Button Flashlight   LED Power 12V DC OUT 12V DC IN 2 1A USB  Indicator Lights HIGH CURRENT Charging Port Output Port    Jump Start Port    CHARGING       Charging the JUMP amp GO  Plug the home adaptor into a 100 240V AC outlet of the proper  plug type   2  Connect the other end of the home adaptor to the 12V DC IN  Charging Port      Or   1  Plug the car adaptor into the socket of the vehicle aux power   2  Connect the other end of the car adaptor to the 12V DC IN  Charging Port        Indicator Lights   Press the power button to check the level of the JUMP amp GO battery   Number of lights ON indicate percentage of charge available    1 20   2 40   3 60   4 80   5 100      NOTE    e The Jump  amp  G
4. o should be charged before initial use    e A minimum of 3 indicator lights must be illuminated before attempting  to jump start a vehicle    e The Jump amp Go will flash all 5 battery indicators simultaneously and  provide an audible beep if the input charging voltage is too low or too  high  To properly charge your Jump amp Go with the Car Charger  the  DC input voltage should be 13 6 to 16 volts  Vehicle charging system  when vehicle engine is running      When charging  the LED indicator lights will sequentially flash  The  percentage of charge completed is indicated by the number of solid  lights as charging progresses  The JUMP amp GO is fully charged when all  lights are solid  3    CHARGING   JUMP STARTING       NOTE  A minimum of 3 indicator lights must be illuminated before  attempting to jump start a vehicle     For charging   powering devices using USB port  1  Plug the USB cable of the device into the USB output port of the  JUMP amp GO   2  Press the JUMP amp GO power button to initiate charging   power to  the attached e      EZ  WS       Forj jump starting 12V vehicle  Before attempting to start 12V vehicle  please make sure at least  3 LED lights are illuminated on the JUMP amp GO when pressing the  power button    2  Connect the Red clamp to the battery Positive     and Black clamp  to the battery Negative     terminals  making sure they have a good  connection  NOTE  REVERSING THE CONNECTIONS MAY RESULT  IN DAMAGE TO THE JUMP  amp  GO  OR PERSONAL INJURY   
5. on vehicle      How long will the JUMP amp GO hold a charge   The Jump amp Go will hold a charge over 1 year      Why does the JUMP amp GO not indicate charging when using the  vehicle power port adapter   Start the vehicle to provide adequate voltage for charging      How do   dispose of the JUMP amp GO when it reaches end of service life   The Jump  amp  Go contains a rechargeable Lithium Polymer  LiPo  battery  pack  This battery pack is self contained and is not replaceable  For  information on battery recycling or disposal call toll free 800 822 8837    POF PFN FO FO FO    SPECIFICATIONS    SIZE  130mm x 78mm x 24mm  5 1    x 3 0    x 0 9     WEIGHT   lt 1 lb  with silicone cover   BATTERY CAPACITY  33300 mWh   OUTPUT  5V 2 1A  12V HIGH CURRENT    INPUT  12V  lt  2A   FULL CHARGING TIME  3 4 hours    STARTING CURRENT  200A    PEAK CURRENT  400A   OPERATING STORAGE TEMP   20  C to 60  C     4  F to 140  F   LIFETIME   gt 1000 Cycles    WARRANTY INFORMATION       Consumer Warranty   This Whistler product is warranted to the original purchaser for a period of  one  1  year from the date of original purchase against all defects in materials  and workmanship  when purchased from an authorized Whistler retailer  This  limited warranty is void if the unit is abused  misused  modified  installed  improperly  or if the housing and or serial numbers have been removed   There are no express warranties covering this product other than those set  forth in this warranty  All express o
6. r implied warranties for this product are  limited to one  1  year  Whistler is not liable for damages arising from the use   misuse  or operation of this product including but not limited to loss of time   inconvenience  loss of use of your product or property damage caused by  your product or its failure to work  or any other incidental or consequential  damages including personal injury     DO NOT RETURN ITEM TO STORE WHERE PURCHASED   FOR WARRANTY INFORMATION  CONTACT WHISTLER CUSTOMER  SERVICE AT 1 800 531 0004     Representatives are available to answer your questions Monday     Friday  from 8 00 a m  to 5 00 p m  CT    Service Under Warranty   During the warranty period  defective units will be repaired or replaced    with he same or a comparable model   at Whistler s option  without charge  to the purchaser when returned prepaid  with dated proof of purchase to  the address below  Units returned without dated proof of purchase will be  considered out of warranty and therefore are not covered by the described  Limited Warranty   Refer to Service Out of Warranty section     Due to the specialized equipment necessary for testing Whistler products   there are no authorized service centers other than Whistler  When returning a  unit for service under warranty  please follow these instructions     1  Ship the unit in the original carton or in a suitable sturdy equivalent   fully insured  with return receipt requested to     Whistler Repair Dept   1412 South 1st St   Rogers 
7. se return your  unit as outlined in the section    Service Under Warranty    along with a  cashier s check or money order in the amount of  50 00  Payment may  also be made by MasterCard  VISA or American Express  Personal  checks are not accepted     WARRANTY INFORMATION       In the event repairs cannot be covered by the minimum service fee   you will be contacted by a Whistler technical service specialist who will  outline options available to you     IMPORTANT  When returning your unit for service  be certain to include  a daytime telephone number and an email address  if applicable      Customer Service    If you have questions concerning the operation of your Whistler product   or require service during or after the warranty period  please call  Customer Service at 1 800 531 0004     Representatives are available to answer your questions Monday   Friday  from 8 00 a m  to 5 00 p m   CT  or visit the F A Q  s at  www whistlergroup com     CORPORATE HEADQUARTERS  1716 SW Commerce Dr  Ste  8  Bentonville  AR 72712   Toll Free  800  531 0004   TEL  479  273 6012   FX  479  273 2927    www whistlergroup com    CUSTOMER RETURN CENTER  1412 South 1st St    Rogers  AR 72756   Customer Service Tel  800  531 0004  Email  info whistlergroup com    P N 404001  09C14    2014 The Whistler Group  Inc     
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Guida alla realizzazione quadri BT  Alpha Personal Priority Display User Manual - Alpha  Special Equipment  GÖRLIG    取扱説明書  NGS Flea Powered  GE EASM & EAMM Data Sheet  Montageanleitung Gas-Brennwerttherme  取扱説明書    Copyright © All rights reserved. 
   Failed to retrieve file