Home

"user manual"

image

Contents

1. July 21 2015 23
2. 0 25 5 sec This adjusted fade time influences fade of RGB and dimmer during DMX operation If time between two receiving DMX values is gt than fade time set in the item M F ti the entire adjusted fade time will be used If time between two receiving DMX values is lt than fade time set in the item M F ti the adjusted fade time will be reduced to fill entire time between the two receiving DMX values e g M F ti 2sec and fixture has received Red 0 DMX after 5 seconds will receive Red 255 DMX It means that red will go to full intensity during 2 seconds M F ti 8 sec and fixture has received Red 0 DMX after 5 seconds will receive Red 255 DMX It means that red will go to full intensity during 5 seconds Max fade time is reduced from 8 sec to 5 sec tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F bALA White colour balance Use this menu item to enable On or disable Off the white balance which is set in the White colour balance menu below f this function is set off the will use maximum value 255 of saturation for red green and blue colour This function has to be set on before adjusting a white balance The white colour balance can be switched on off for each LED output independent C bAL White colour balance setting The menu gives access to the setting of the white balance The white colour balance can be set for each LED output ind
3. Zone 3 0 255 Red LEDs saturation control 0 100 proportional 10 10 2 Green LEDs Zone 3 0 255 Green LEDs saturation control 0 100 proportional 11 11 Blue LEDs Zone 3 0 255 Blue LEDs saturation control 0 100 proportional 12 12 White LEDs Zone 3 0 255 White LEDs saturation control 0 100 proportional 10 13 13 1 1 Red LEDs Zone 4 0 255 Red LEDs saturation control 0 100 proportional 11 14 14 2 2 Green LEDs Zone 4 0 255 Green LEDs saturation control 0 100 proportional 12 15 15 3 3 Blue LEDs Zone 4 0 255 Blue LEDs saturation control 0 100 proportional 16 16 White LEDs Zone 4 0 255 White LEDs saturation control 0 100 proportional Virtual colour wheel all zones No function step 5 1s White tones cool gt warm proportional Blue Blue full Red Green White 0 step a a Red 0 Green gt up Blue full White 0 proportional 56 57 95 96 97 134 135 136 174 175 176 214 215 216 254 255 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 PSU Outdoor Xtreme Light Blue Red 0 Green full Blue full White 0 Red 0 Green full Blue gt down White 0 Green Red 0 Green full Blue 0 White 0 Red gt up Green full Blue 0 White 0 Yellow Red full Green full Blue 0 White 0 Red full Green gt down Blue 0 White 0 Red Red full Green 0 Blue 0 White 0 Red full Green 0 Blue gt up White 0 Magenta Red full Green 0 Blue full White 0 Red gt down Gr
4. mnm 1 ULI I MOTORS O x PREV NEXT ENTER ESCAPE De The control buttons have the following functions Y ESCAPE button leaves menu without saving changes lt l ENTER button enters menu confirms adjusted values and leaves menu A _ UP and Y DOWN buttons move between menu items on the same level sets values Robe Universal Interface Run the RDM network and click with the right button of the mouse on the fixture and select the Remote LED display option from the menu list as shown below 13 PSU Outdoor Xtreme RDM network 10 12 Eie Scan Tools Options View Help Ber vE El DMX Network QQ e ne D Get Set Parameters e a Bom Network 1 device Device UID 52 53 00 2d 00 a3 root device 3 1 DMXS12 Current Personality mode 3 y 7 Identify Device ofr y 1 DMX Start Address 13 P Device Label Noname 1 Device Reset warm y Lamp State A Lamp On Mode A 0 Display Invert fo y Display Level 2557 Pan Invert A Tilt Invert A Patch DMX Addresses Collect Parameters View Sensor Values Remote LED Display Set Parameter Ready The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons RDM network 10 12 Elle Scan Tools Options view AA oe Es Get Set Parameters B Device UID 52 53 00 2d 00 23 root
5. mo 7 DIED Use this menu for control the fixture without connected DMX console To control fixture channels 1 Use the UP DOWN buttons to find Man M menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired effect channel List of control channels rEd1 rEd4 red LEDs saturations LED modules 1 4 GrE1 GrE4 green LEDs saturations LED modules 1 4 bLu1 bLu4 blue LEDs saturations LED modules 1 4 Whi1 Whi4 white LEDs saturations LED modules 1 4 MACr colour macros Stro a strobe shutter dimr a dimmer 4 Press the ENTER button and use the UP DOWN buttons to set value press the ENTER button to confirm it 6 5 Test sequences Use this menu to run test sequences without an external controller which will show you some possibilities of using the PSU Xtreme 6 6 Stand alone setting The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture Auto Automatic playback This function allows you to select the program which will be played after switching the fixture on Selected program will be played continuously in a loop 1 Use the UP DOWN buttons to find St AL menu Press the ENTER button Use the UP DOWN buttons to select Auto item Press the ENTER button Use the UP DOWN buttons to select desired program Press the ENTER button to con
6. the device and consult installation with an expert 3 2 Connection to the mains The PSU Outdoor Xtreme uses a 5 cored power data cable The 3 cores serve for the power supply 3 x 1 5mm and next 2 shielded cores are intended for DMX connection a e e ee ee IEEE o E CN The power data cable is connected to a junction box as shown on the picture below Terminal plate ZAG6 PSU Outdoor Xtreme 5 PSU Outdoor Xtreme Connect the junction box to mains and DMX acording to the tables below Power connection Green Green yellow Do not overload the supply line and the connecting leads DMX connection LED output e sput DMX Data 3 3 Connection between LED modules and PSU Outdoor Xtreme unit Four pairs of the Igus CF9 03 08 cable serve for interconnection of the LED modules and the control unit The Chogori connectors are marked by self adhesive labels LED1 LED2 LED3 LED4 next to the connectors and the following order of cable connections has to be kept to ensure correct operation of the driver LED1 LED Zone 1 LED2 LED Zone 2 LED3 LED Zone 3 LED4 LED Zone 4 NOTE max length betwen LED module and control unit 80m at 350mA load 20m at 700mA load 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you need either Robe Universal Interface or RDM Commu
7. ANOLIS PSU Outdoor Xtreme PSU Outdoor Xtreme W Ys BN Wiz i m Z Q fr Sr USER MANUAL Version 1 4 PSU Outdoor Xtreme Table of contents 1 SafetyiinstructiOns vern oren reei aaa coaui su ed aeta dite Sova eden leden nad ed etend 3 2 Fixture exterior VIEW auster A lo 4 Stalin dad deta 5 3 LMounting the fixtures lt di denke tan dee a at cti 5 3 2 Connection to the MaS cti AA Eee eer AAA 5 3 3 Connection between LED modules and PSU Outdoor Xtreme unit nennen eeens enneerenseerenenenneeeennenenn 6 SA SELUING NO CONTO ido aaneen ripio 6 3 50 DMA S12 connections init 7 JO Wireless DMX Operat OM a a lia dad oa nde 7 4 PSU Outdoor Xtreme DMX pProtocol cccccccccccssssssssececececeeseseseceescesseseeaeeeeeessesseeseaaeseseescessesaeaeeeecesseseuaeaeeeesenssensaaaaas 9 5 CONTRO MANI Pt AA A A A AA a a dee A A AA Ai 11 6 Fixture MEN Uca ie 13 6 1 Fixture Address idas 15 6 2 Eit reinformatlON ri A AAA keer etende 15 PESO A A IE A da 15 6 4 Mandal Mode a e dan Heens 17 6 5 MESES UNC ii A A en ee eee Be eee 17 Al SA 17 6 Specia NUNCIO dee een Ad lesa is aks 18 7 LEChnical e dass 21 8 Cle ning and maintenance cit incidan da ieia nai de daneen ed it A ado 23 PSU Outdoor Xtreme FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR PSU Outdoor Xtreme Save it for future reference This device has left our premises in absolutely
8. a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack Keep compustible materials at least 10 cm away from the fixture If the fixture has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Avoid brute force when installing or operating the fixture The fixture was designed for outdoor use and it is intended for professional application only It is not for household use When choosing the installation spot please make sure that the fixture is not exposed to extreme heat or dust Avoid using the unit in locations subject to possible impacts 3 PSU Outdoor Xtreme The fixture body never must be covered with cloth or other materials Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt to dismantle or modify the unit Please consider that unauthorized modifications on the fixture are forbidden due to s
9. afety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc 2 Fixture exterior view Correct interconnection of LED modules and control unit has to be D kept The Chogori 1 gt a connectors are marked ONE F by self adhesive labels LED1 LED Zone 1 LED2 LED Zone 2 LED3 LED Zone 3 LED4 LED Zone 4 1 PSU 2 Power data cable 3 Junction box Pi 4 LED modules connection cables Chogori connectors females 1 2 3 08BFFA SL8001 4 Female Rear view y 5 6 5771 y 7 ee 8 Rear view 4 PSU Outdoor Xtreme 3 Installation 3 1 Mounting the fixture Ensure that the structure truss wall to which you are attaching the unit is secure Fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation The PSU Outdoor Xtreme can be arranged in any position orientation The housing of the control unit offers two mounting holes each with a diameter of 13mm 576 Caution Overhead installation requires experience Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install
10. al in r UnL Wireless DMX unlink The item serves for unlinking the fixture from a DMX transmitter Hold Holding DMX If the function is on the last received DMX values are held in case that DMX data receiving was interrupted e g disconnected DMX controller uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 if you want to use a serial port of PC Robe Universal Interface if you want to use an USB port of PC Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address programs 1 2 and all items in the menu PErS will be set to their default values To update software in the fixture I Installation of the DMX Software Uploader 18 PSU Outdoor Xtreme 1 DMX Software Uploader program is available from theAnolis web site at WWW anolis cz 2 Make a new directory e g Anolis_ Uploader on your hard disk and download the software into it 3 Unpack the program from the archive ll Fixture software updating If you use the RDM Communicator 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the RDM communicator to the fixture and switch this fixture t
11. d be set before start programming e g if you want to create program with 10 steps set P End 10 rEd1 rEd4 a red LEDs saturation 0 255 module 1 4 GrE1 GrE4 a green LEDs saturation 0 255 module 1 4 bLu1 bLu4 a blue LEDs saturation 0 255 module 1 4 Whi1 Whi4 a white LEDs saturation 0 255 module 1 4 MACr colour macros 0 255 both modules Stro a strobe shutter 0 255 both modules dimr a dimmer 0 255 both modules F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY this item duplicates the current prog step to the next prog step The item P End is increased automatically 6 Use the UP DOWN buttons to set a DMX value of the channel and then press the ENTER button 7 Use the UP DOWN buttons to select next channel and press the ENTER button 8 After having set all channels in the current program step press the ESCAPE button to go by one menu level back and select another program step 6 7 Special functions COcr Ji Ol rdML Code This menu item shows the first part of the RDM identification code rdMH Code This menu item shows the second part of the RDM identification code rAdl Wireless DMX only wireless DMX version The menu serves for reading of the wireless operation status r InF Signal level The menu item shows level of received sign
12. device 8 DMX Network QA A fe Me te H A Bm Network 1 device I DMX512 Current Personality Mode 3 F Identify Device of gt 21 DMX Start address 18 Device Label Noname Device Reset warm y Remote LED Display Ready 14 PSU Outdoor Xtreme 6 1 Fixture Address Use this menu to set the DMX address of the fixture To set a DMX address 1 Use the UP DOWN buttons to find A001 menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired start address 4 Press the ENTER button to confirm the choice 6 2 Fixture information I C INFO Use this menu to read useful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press the ENTER button to confirm the choice Po ti Power On Time Use the menu item to read the number of operation hours totL the function shows the total number of the operation hours since the PSU Xtreme has been fabricated rESEt the function shows the number of the operation hours that the PSU Xtreme has been powered on since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button DM In DMX values Select this function to read DMX
13. ect button Note we recommend to cancel all running programs before starting the Software Uploader 19 PSU Outdoor Xtreme If the connection is OK click on the Start Uploading button to start uploading It will take everal minutes to perform software update If the option Incremental Update is not checked all processors will be updated including processors with the same software version If you wish to update only the latest versions of processors check the Incremental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line with the text The fixture is successfully updated will appear in this window and the fixture will reset with the new software 20 PSU Outdoor Xtreme 7 Technical specifications Power supply e Electronic auto ranging e Input voltage 100 240V AC 50 60 Hz e Power consumption 600W e Fuse F12A 250V Control e Control USITT DMX 512 RDM support e DMX protocol modes 5 12 16 19 4 5 control channels e Manual control of all effects via RDM communicator e 2 user editable programs each up to 68 steps e RGBW colour mixing e Built in colour macros e White colour balance adjusting for each LED output separately LED output e Max Output current 350mA or 700 mA per colour e Number of LED zones 4 e Max load per zone 48LEDs 1W or 3W LEDs max 12 LEDs per colour or 12 RGBW multichips 10W Connection e LED mod
14. een 0 Blue full White 0 Blue Red 0 Green 0 Blue full White 0 Shutter Strobe all zones Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow gt fast Closing pulses in sequences fast gt slow Shutter open Random strobe effects from slow to fast Shutter open Dimmer all zones Dimmer intensity from 0 to 100 10 step proportional step proportional step proportional step proportional step proportional step step step proportional step proportional proportional step proportional step proportional PSU Outdoor Xtreme 5 Control menu map Default settings Bold print Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 001 512 few fee SP Hi tE rSEt ie Mod 3 Mod 4 Mod 5 Mod 6 rAd t 0 1 25 5 1 default 0 200 255 11 PSU Outdoor Xtreme Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 ot Oats e aE 12 PSU Outdoor Xtreme Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 Oooo Pe AO IE T o i E 0 255 communicator Connect the RDM communicator to the fixture and from the menu Control select the Remote LED display item The fixture s control display with the four control buttons will appear on the screen of the RDM communicator E EE E ID 5253 0024000A Remote LED Display
15. ependent To set the white colour balance 1 Use a DMX controller or the Man C menu to set all LEDs on max saturation 2 Use the UP DOWN buttons to find the Pers menu 3 Press the ENTER button 4 Use the UP DOWN buttons to select the C bAL menu Press the ENTER button and the rEd1 item will appear on the display Press the ENTER button and use the UP DOWN buttons to set new max value for the red LEDs Press the ENTER button to confirm the choice Use the UP DOWN buttons to select next colour the GrE1 Repeat steps 6 7 for this channel 10 Use the UP DOWN buttons to select the last colour the bLu1 and repeat steps 6 7 for this colour 11 Repeat this procedure for all LED outputs 12 Use the UP DOWN buttons to find the item Stor and press the ENTER button to save adjusted values 000 AO UI LoAd Load of LED outputs The menu allows to choose desired current 350mA or 700mA for each LED output Warning Set the Load item before connecting the LED modules to the driver Never connect 1Watt LEDs to the 700mA output otherwise these LEDs vill be destroyed In Po Init effect positions Use this function to set all effects to the desired positions to which they will move after switching the fixture on if DMX is not being received dF SE Default Settings The menu item sets all fixture parameters to the default factory values 16 PSU Outdoor Xtreme 6 4 Manual mode
16. firm the choice DU AN PLAY Playing program By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected 1 Use the UP DOWN buttons to find St AL menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired program 4 Press the ENTER button The selected program runs in a loop Edit Editing a program The fixture offers 2 freely editable programs PrG 1 PrG 2 each up to 68 steps Every program step includes a fade time the time taken by the step s channel status to reach the desired level and a step time the total time occupied by the step in the program E g If F tim 5 second and S tim 20 second effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog step 17 PSU Outdoor Xtreme 1 1 Use the UP DOWN buttons to find St AL menu and press the ENTER button 2 Use the UP DOWN buttons to select Edit menu and press the ENTER button 3 Use the UP DOWN buttons to select a program you want to edit PrG 1 PrG 2 and press ENTER button 4 Use the UP DOWN buttons to select a desired program step St 01 St 68 and press ENTER button 5 Use the UP DOWN buttons to select a channel you want to edit and press the ENTER button List of editable items P End a total number of the program steps value 1 68 This value shoul
17. nicator Please see the Robe Universal Interface or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below NOTE Do not connect the RDM communicator and the The Robe Universal Interface to the fixture at the same time PSU Outdoor Xtreme 1 Robe Universal Interface Control PC USB cable Power data cable Robe Universal Interface Junction bi ox DMX console pi Tee Power cable DMX512 DMX data cable 2 RDM Communicator Note DMX controller has to be disconnected from the fixture when the RDM communicator is operated RDM Communicator Power data cable Junction box Power DMX data cable DMX512 RDM protocol 3 5 DMX 512 connection To build a DMX chain 1 Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture 3 Always connect the DMX output with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate the output of the last fixture with a 120 Ohm resistor wired betwen data and data in order to ensure the proper transmission on the data link 3 6 Wireless DMX operation The wireless ver
18. o the update mode 1 Use the UP DOWN buttons to find SPEC menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select uPd item 1D 5253 00240004 uPd SIDO O X 4 Press the ENTER button 5 Use the UP DOWN buttons to select yES option 6 Press the ENTER button Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 3 Disconnect the RDM communicator from the fixture 4 Connect serial port of your PC with a DMX input of the fixture if you using the flash cable RS232 DMX If you use the Robe Universal Interface 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the Robe Universal Interface to the fixture and switch this fixture to the update mode 1 Run the RDM Network and select menu item Remote LED Display 2 Use the UP DOWN buttons to find SPEC menu 3 Press the ENTER button 4 Use the UP DOWN buttons to select uPd item i 2177 5 Pressthe ENTER button 6 Use the UP DOWN buttons to select yES option 7 Pressthe ENTER button Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 8 After switching the fixture to the update mode cancel the RDM Network program Run the Software Uploader program Select desired COM select Robe Universal Interface if the USB port is used and then click on the Conn
19. perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety instructions DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT Make sure that the available voltage is not higher than stated on the rear panel of the fixture This fixture should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power data cord is never crimped or damaged by sharp edges Check the fixture and the power data cord from time to time Do not install the unit near naked flames During the operation the housing becomes hot up to 60 C Refer servicing to qualified service personnel This fixture falls under protection class Therefore this fixture has to be connected to
20. sion of the PSU Outdoor Xtreme is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal CRMX module operates on the 2 4 GHz band To set fixture to wireless DMX operation 1 Set the unlink time in the menu PErS PErS gt rAd t Default value is 1 hour 2 To link the fixture with DMX transmitter PSU Outdoor Xtreme The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter After linking the level of DMX signal 0 100 is displayed in the menu item r InF SPEC gt rAdl gt r InF To unlink the fixture from DMX transmitter The fixture can be unlinked from receiver via the menu item UnL SPEC gt rAdl gt UnL PSU Outdoor Xtreme 4 PSU Outdoor Xtreme DMX protocol RETA 1 0 Mode channel Sanda Value Type of control Red LEDs Zone 1 0 255 Red LEDs saturation control 0 100 proportional Green LEDs Zone 1 0 255 Green LEDs saturation control 0 100 proportional Blue LEDs Zone 1 0 255 Blue LEDs saturation control 0 100 proportional White LEDs Zone 1 0 255 White LEDs saturation control 0 100 proportional Red LEDs Zone 2 0 255 Red LEDs saturation control 0 100 proportional Green LEDs Zone 2 0 255 Green LEDs saturation control 0 100 proportional Blue LEDs Zone 2 0 255 Blue LEDs saturation control 0 100 proportional White LEDs Zone 2 0 255 White LEDs saturation control 0 100 proportional Red LEDs
21. ules connection cable Igus CF9 03 08 connectors Chogori NOTE max length betwen LED module and control unit 80m at 350mA load 20m at 700mA load e Connection between control unit and junction box 5 cored power data cable e junction box Rigging e Via slots in base of the driver Temperatures e Maximum ambient temperature 40 C e Maximum housing temperature 60 C 21 PSU Outdoor Xtreme Dimensions mm PSU Outdoor Xtreme Weight e PSU unit 9 kg Protection factor e IP 67 Included items e 1x PSU Outdoor Xtreme e 1x Junction box No 99012672 e 1x User manual e 4x Connector Chogori CGRBDU 08BMMA SL8001 male e 1x Gasket of cable grommet M20 PF P N 1305 1388 22 PSU Outdoor Xtreme 8 Cleaning and maintenance DANGER Disconnect from the mains before starting any cleaning or maintenance work Rinse off loose dirt with a garden hose or low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts If the power supply cable of this device will be damaged cable firmly connected with the device it has to be replaced by authorized distributors only in order to avoid hazards Specifications are subject to change without notice
22. values of each channel received by the fixture tEMP Fixture Temperatures Select this menu to read the temperatures of the fixture Cur t the current temperature of the fixture inside Hi tE the menu item shows the max temperatures of the fixture inside since the PSU Xtreme has been fabricated rSEt the menu item shows the maximum temperatures of the fixture inside since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button The temperatures can be displayed either in C or F units see option tEM U in the menu Pers VErS Software Versions Select this function to read the software versions of the fixture processors IC1 LED modules control processor 1C2 EEprom 6 3 Personality OC ro 5 Use this menu to modify the PSU Xtreme operating behaviour DM Pr DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode 15 PSU Outdoor Xtreme rAd t Unlink time Use this menu to set time after that the linked fixture will be unliked from the transmitter if the transmitter does not transmit DMX signal OFF Fixture is permanently linked to the transmitter 0 1 25 5 Time from 0 1 25 5 hrs Default value is 1 hr M F ti Max Fade time Select this menu item to set a desired max fade time

Download Pdf Manuals