Home
USER`S MANUAL - Tendo Sports Machines
Contents
1. 6 Windows will detect the driver and Click Next to continue installation Select the USB Serial Converter driver for your computer 7 Click Finish to continue and let Windows copy the needed files to your hard disk 8 You can check the Device Manager and see the USB Serial Port COM 2 Device Manager action vw ces EMS EA 1488 1 KOBLSNWS7F1G5 El m Computer EE Disk drives oe Display adapters EEE DVD CD ROM drives H Floppy disk controllers x Floppy disk drives Ea Human Interface Devices E IDE ATAJATAPI controllers Es Keyboards ce Mice and other pointing devices E m Monitors A 4 Ports COM amp LPT YY Communications Port COMI po Y Communications Port COM jo A ECP Printer Port LPT1 LUSE to Serial Comm Pork E E 7 Saiki video and game controllers E System devices ALE Universal Serial Bus controllers Important notice The wireless bluetooth connection works only if the Tendo Computer Bluetooth and the Tendo Microcomputer Bluetooth have the same Set Number 3 Connection microcomputer and computer 1 Plug the Tendo Microcomputer Bluetooth connector into the connector on the top of the microcomputer 2 Plug the Tendo Computer Bluetooth USB connector into the appropriate USB connector on your computer 3 Switch the microcomputer on and wait till blue LED of the Bluetooth indicates connection Microcomputer Bluetooth Computer Bluetooth It is highly recommend
2. You need the Tendo Bluetooth package for each microcomputer connection the the computer Workstation panel of values lt is possible to set the measured parameter which is displayed on the panel of values of the Tendo Power Analyzer program WORKSTATION 1 WORKSTATION 1 O O AVG Velocity AVG Power AVG Velocity Part AVG Power PEAK Velocity Part AVG Power O PEAK Velocity PEAK Power PEAK Force PEAK Power RESET 100 y 70 kg REP 1 lt is possible to choose between average power partial average power peak power average velocity peak velocity peak force To change the parameter mark particular dot Microcomputer setup panel lt is possible to change the microcomputer settings from this panel MICROCOMPUTER SETUP AVG Power AVG Velocity Part AVG Power PEAK Velocity PEAK Power PEAK Force Eccentric velocity E J Rest Time Parameter displayed in microcomputer upper display Settings limits for audio signal load filter range for partial average power and range for peak force turn on off for eccentric velocity measurement and turn on off for measurement of the rest time 5 1 Administration Center Before you start use the system it is recommended to fill in the Administration Form to create database for saving the files To open or close Administration Menu click on red Arrow button in upper right corner of the program window Click Admin Center
3. each repetition with value of average and peak power performed below lower limit of audio Signal Blue or grey row represents actual repetition displayed in Graph Section 8 2 Graph Section There are 3 graphs in this program section Velocity Displacement Time Force Displacement Time Power Displacement Time It is possible to select Displacement or Time axis by mark a Radio Option Button located below graphs There are two curves in each graph The black curve is for repetition with maximum value of Average Power or Velocity The colored curve is for selected repetition 1 5 i 2 1 0 2 1 0 E E 0 5 0 5 0 0 0 0 1500 1500 1000 1000 200 500 Force N Force N 500 500 1000 1000 2000 2000 1500 1500 1000 4000 900 Power W Power W 4000 E E E E 00 01 02 03 04 05 06 0 7 08 09 1 0 Displaceme Time 16 If you place cursor on selected point of the Velocity Displacement Time curve actual values of displacement time velocity force and power are displayed 2 0 1 3 6 Values belonging to this point Repetion 1 Displacement 0 36 ml Time 0 57 s F Velocity 1 19 m s do 7 Force 1407 64 N Power 1661 02 W Velocity mi s 0 0 If you place cursor on selected point of Force Power Displacement Time curve actual values of displacement and force power are displayed 1500
4. 19 2 Raw Data for selected repetition from the exercise set RAW DATA SUMMARY Back Squat Strength training report repetion no 0 LOAD 110kg DATE 7 3 2012 23 01 17 PERSON Tendoman John PAZ NO GROUP Tendosport O NOTES ee P o WW er Wel o city yA of t h E b E si SPORTS MACHINES No VW mz rep 1079 10 i 1203 78 132 42 0 02 1375 43 302 60 0 03 1464 52 497 94 0 04 1515 20 696 99 0 05 1488 17 773 85 0 06 1455 79 844 36 8 5 Print data Export data to the Microsoft Excel program and use print commands Precaution Do not use the system in places subject to excessive humidity dust shock or vibration Protect the unit from becoming wet and do not drop or strike the unit against hard objects Important Recommendation It is useful archive data periodically at the end of training cycle or season and then delete old files from program database because database could be extended to very big size Please check our web site www tendosport com for the latest updates of Tendo Power Analyzer software TENDO Sports Machines M R Stefanika 19 911 01 Trencin Slovak Republic Phone fax 421 32 6401500 e mail tendo tendosport com www tendosport com 20
5. Exercise Note to the excercise Date 25 9 2014 oe E ESeteeh room E gt E cmo eso US Update or Cancel 2 Choose Group 3 Choose Person Person is selected from particular Group assigned in Administration Form lt is possible add new person for particular group who is not in database Write new name and click Add to save new name 4 Choose Exercise It is not recommended to save data without filling Personal Info group person and exercise Note it is possible to put down any note If you do not fill in Personal Info software saves files to the Tendo Sports Machines Temporary Files The File name is automatically assigned in form Person exercise Load kg Date Time e 9 Tendoman Back Squat 45kg 2006 8 2 1 To close Personal Info window click on Personal Info panel or click Cancel Update or Cancel It is possible update existing personal information direct in Personal Info or in Admin Center To change or add new info in Personal Info click Update If Personal Info window is closed basic information for Person Group Exercise and Load is appear above graph section PERSONAL INFO 13 6 4 Partial Average Power Partial Average Power is the value of average power which is measured from start 0 to a certain predefined percent value of the range of motion Default setting is 50 setting range from 1 to 100 lt is possible to change range for the partial average power
6. Power Analyzer software Click Start Settings Control Panel select Add or Remove Programs Select TENDO Power Analyzer Follow the instructions given on screen to complete uninstallation 2 2 Installing TENDO Power Analyzer software Computer program has an AutoPlay feature that will automatically start the setup screen for the software program when the CD is placed in the computer Run the installation through the screen that appears after inserting the disc If you are installing a program manually follow the below steps Insert CD in your PC CD ROM drive Select My Computer and select the CD drive click setup exe and follow the instructions given on screen to complete the installation When the installation is complete a new program called TENDO Power Analyzer is added to your system Also an icon will be placed on your computer desktop a Iil endo Power Analyzers 2 3 Driver Installation Before you use the Tendo Power Analyzer software it is necessary to install the drivers for the Tendo Bluetooth Your computer does not recognize the Tendo Bluetooth as bluetooth device but as a USB Serial COM Each Tendo Bluetooth is paired so the user does not need to pair the Bluetooth Follow the steps below to install Windows drivers 1 Open Windows Device Manager 2 Inthe Device Manager make sure the device you re attempting to install is not already listed from past install attempts If the device is f
7. you want to use and click left mouse button 2 0 Copy Save Image As Page Setup Print Velocity mis Show Point Values Un Zoom Undo All Zoom Pan Set Scale to Default You can also Zoom any part of graph Press the left button of mouse hold and stretch the window to the part of graph you want zoom and release the left mouse button 18 Velocity ms D a Velocity mis o Sa 0 2 A 0 0 Default View Zoom View Back to Default View click the right button of mouse and select Set Scale to Default or Un Zoom 8 4 Export data to Microsoft Excel Program Tendo Power Analyzer program allows you to export data to the Microsoft Excel program To open the file click Report on workstation panel to export data from workstation to the Microsoft Excel There are 2 Report Sheets 1 Summary of the exercise set EXERCISE SUMMARY Back Squat Waist Strength training report LOAD 100 kg DATE 26 9 2014 9 28 05 PERSON Tendoman AS NO O GROUP Tendosport NOTES SPORTS MACHINES Es Pee Es AVERAGE Range0 0cm tes 1 1147 1039 2 079 1059 3 1108 7 EE 7 1 58 r 1 020 96 7 T 4 1118 1 14 oT 1 1 58 94 1030 g7 1 01 5 1049 1 07 97 1715 1 52 65 941 69 0 93 6 941 0 96 82 1403 1 27 TO 912 36 0 68 TOTAL WEIGHT LIFTED 880 k Copyright 2008 Tendo Sports Machines All rights reserved
8. Tendo Power Analyzer Computer Software USER S MANUAL Version V 4 0 5 www tendosport com Contents 1 Introduction 3 2 Installation 3 2 1 Uninstalling software 3 2 2 Installing software 3 2 3 Driver Installation 4 3 Connection microcomputer and computer 6 4 Indication of the connection 7 5 Start Tendo Power Analyzer TPA program 8 5 1 Administration Center 8 6 Online mode 10 6 1 A connection with Interface 10 6 2 Microcomputer setting 11 6 3 Personal Information 12 6 4 Partial Average Power 13 6 5 Save data 14 7 Off line mode 14 8 A work with program 14 8 1 Table section 15 8 2 Graph Section 16 8 3 Work with graph 18 8 4 Export data to Microsoft Excel Program 19 8 5 Print data 19 Please check our web site www tendosport com for latest updates for the Tendo Power Analyzer software 1 Introduction You will need the following items for TENDO Power Analyzer computer program usage Microcomputer system TENDO Power Analyzer Power Analyzer WL or Power Analyzer Tendo Bluetooth set The Tendo Bluetooth set includes Microcomputer Bluetooth E Computer Bluetooth TENDO Power Analyzer installation CD software The minimum computer requirement Processor 1 6GHz RAM 512Mb Operating system Windows XP Windows Vista Windows7 Windows 8 32bit or 64 bit 2 Installation The Tendo Weightlifting Analyzer computer program does not work with new Power Analyzer system 2 1 Uninstalling TENDO
9. Velocity m s erson Power W 00 00 01 02 03 04 05 06 0 7 08 Displacement m 9 Displacement Time 8 1 Table section Average Values leak Values Partial Avg Power Velocity ofthe best Power ofthe best Velocity of the AVG Power best Eccentric m s rep WW rep m s rep WV rep Velocity 1147 117 HM 2006 166 100 1039 0 99 1079 11 j 94 1933 1 59 628 1059 09 1108 113 EJES 1968 1 58 1020 0 94 1118 1 14 97 1583 1 58 1030 1 07 1043 107 El 1715 1 52 341 0 93 341 0 96 1403 1 27 912 0 66 Cn dm Cu Mi CL a om Table section contains Repetition Number Average Power Average Velocity Percent of the best rep for average value Peak Power Percent of the best rep for peak power Peak Velocity Percent of the best rep for peak velocity AVG Partial Power partial average power for predefined range from O to setting value 15 Percent of the best rep for partial average power Eccentric Velocity average velocity in downward movement Coloured Column of the best rep represents column chart Percent Value of Best of power and velicity Column colors depends on settings of an audio signal for microcomputer each repetition with value of average and peak power performed above upper limit of the audio signal Blue column each repetition with value of average and peak power performed between upper and lower limit of audio signal Red column
10. a i Values belonging to this point Repetion 7 1000 0 04m 1550 54N F 900 Force N 900 1000 Recommendation It is possible to open up to 8 different files in the computer program each file at the different workstation Each workstation in the computer program represents one microcomputer workstation lt is also possible to open the Tendo Power Analyzer program several times The purpose for that multi opening of program is a comparison of 2 or more different files 1 Click Restore Down button on the upper right corner of program to make each window smaller 2 Goto the lower right corner of the program window click and hold left mouse button and you can change the program window dimension 17 8 Open selected file in each opened Tendo Power Analyzer program and you get 2 or more independent measurements on computer screen pn e 2 Mo WORKSTATION 1 TENDOMAN TENDOSPORT re BACK SQUAT WAIST 100KG AVG Velocity O 0 AVG Velocity Part AVG P PEAK Veloci 0KG i Tendoman Tendosport Back SquatWaist 100KG a ower Y Y elocity Part AVG Power PEAK Velocity dir oras ram PEAK Power PEAK Force PEAK Power PEAK Force A D O CT TT 82 w ve Y 100 E Uy A EN 100 kg W Velocity ms REP 6 al 8 3 Work with graph Move the cursor to the graph area Click the right button of mouse and a command window will appear Select the command
11. ce o USB Device A device driver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the installation click Next What do you want the wizard to do seeeeendenesennsecnsnsnsnensnenssansnsesecnsesnsennsuansnsnsescanensenessansnsnsnsnsesnsnanssensnansescsnensnesssansnsnesssaessonesenn C Display a list of the known drivers for this device so that can choose a specific driver lt Back Cancel 3 Windows will detect the driver and Click Next to continue installation Select the USB Serial Converter driver for your computer Found New Hardware Wizard Driver Files Search Results The wizard has finished searching for diver files for your hardware device The wizard found a driver for the following device USB Device Windows found a driver for this device To install the driver Windows found click Next a 4serport inf Cancel 4 Click Finish to continue and let Windows copy the needed files to your hard disk Found New Hardware Wizard E Completing the Found New Hardware Wizard 7 Prolific USB to Serial Comm Port Windows has finished installing the software for this device To close this wizard click Finish 5 Run the Found New Hardware Wizard for USB Serial Port This wizard helps you install software for the USB Serial Port Select Install the software automatically Click Next to continue
12. computer is switch on the workstation panel of values for this microcomputer is green O AVG Velocity Part AVG Power PEAK Velocity PEAK Power PEAK Force RESET 0 w 0 70 kg REP 1 panel of values 10 If the microcomputer is switch off the connection with the computer will be lost the workstation panel of values for this microcomputer is black To renew connection click Connect O 0 AVG Velocity Part AVG Power Y PEAK Velocity PEAK Power Y PEAK Force RESET 0 W 0 70 kg REP 1 panel of values To Disconnect connection click Disconnect DEVICE CONNECTED ON CONNECTED DISCONNECT o More microcomputer units connected to the computer If you would like to connect more microcomputers to the computer you need additional Tendo Bluetooth Set Plug another Tendo Computer Bluetooth USB connector into the appropriate USB connector on your computer Then open new Tendo Power Analyzer software window by clicking on the Tendo Power Analyzer desktop icon New window will open as Workstation 2 black workstation panel of values indicates offline mode WORESTATION 1 WORKSTATION 2 WORKSTATION 3 ON MNR eta Part AVG Power O PEAK Velocity PEAK Power PEAK Force 0 M AVG Velocity Part AVG Power O PEAK Velocity PEAK Power PEAK Force OM Vie E Part AVG Power O PEAK Velocity PEAK Power PEAK Force RESET O W Disconnected or micro
13. computer is switched off RESET 0 W The software detects all COM Ports 11 6 2 Microcomputer setting The program reads actual microcomputer setting if not press Reset button It is possible change settings by using the microcomputer itself or using the TENDO Power Analyzer program To change the microcomputer settings use setup panel Audio signal Load Filter MICROCOMPUTER SETUP AVG Power Y AVG Velocity Part AVG Power PEAK Velocity PEAK cower O amp PEAK Force Audio re oaa ES El Partial Percent fiter Ea Eccentric velocity E E Rest Time Parameter which is displayed in upper microcomputer display Reset button deletes data from the microcomputer and unsaved data from software O 0 AVG Velocity Part AVG Power PEAK Velocity PEAK Power Y PEAK Force j RESET 0 w 0 70 kg REP 1 lt is possible to transfer data saved in the microcomputer memory Make a connection with microcomputer and then press Read Memory button on Tendo Power Analyzer software Data are transferred to the software without graphs 6 3 Personal Information 1 It is recommended to fill in a table Personal Info for data identification It is possible to do it before or after the exercise but before data will be saved 12 Groug dei Tip Quick Search Type first letters to combo box Person Add new name type new person and click Add Add Do not forget fill in Group
14. ed from the exercise it is possible save them by clicking on Save Then click Yes to confirm for saving data If you do not fill in Personal Info software saves file in the Tendo Sports Machines Temporary Files The File name is possible to rename anytime Each workstation window works independently The workstations which are not connected are possible to use in offline mode 7 Offline mode If the microcomputer is not connected with computer it is possible to open saved files from database and analyze result of measurements Click Open on workstation panel and select the group exercise name and select particular file from database Database directory C Users Documents Tendo SportsMachines Group Exercise Name 14 8 A work with program TPA program has 2 sections for results analyzing Section of charts and table section WORKSTATION 1 TENDOMAN TENDOSPORT Peak Values Partial Avg Porser in A Power ofthe best Velocity of the AVG Power eo best Eccentric mem BACK SQUAT WAIST 100KG w rep m s rep WI rep Velocity AVG Velocity Part AVG Power PEAK Velocity 111 100KG 2006 _ 100 166 1002 Ss CC og PEAK Power PEAK Force Rep 6 26 9 20149 28 04 be bees bas Pea j y 1 j i a 14 7 1883 94 158 SS 1030 Sm 101 RESET i 5 E 3 3 y 1715 BM 1 52 y 941 SSS os i CO 1277 912 CBS os 82 W 941 100 kg REP 6
15. ed to use full charged batteries for microcomputer if the Tendo Bluetooth connection is used If microcomputer battery voltage is low the microcomputer does not transfer the data to the computer 4 Indication of the connection Blue LED light indicates correct connection between microcomputer and computer Green LED light indicates the connection is lost 5 START TENDO Power Analyzer TPA program Start the Tendo Power Analyzer program by double clicking the Tendo Power Analyzer icon on your computer desktop When you open the application you will see a program window workstation panel of values Administration Menu workstation number 2 Power Analyzer by Tendo Sports Machines WORKSTATION 1 No w m s y re W rep Velocity D ECO ECTED ON COM26 USB O AVG Velocity i p y EVICE CONNECTED ON COM26 USB Part AVG Power PEAK Velocity There are no items in this view PEAK Power PEAK Force DISCONNECTED RESET ho MICROCOMPUTER SETUP r AVG Velocity Part AVG rower PEAK Velocity PEAY Power O O PEAK Force ECS E Boat O 00 01 02 03 04 05 06 07 08 0 9 _ A __ _ _ _ _ _ Displacement m x 9 Displacement Time z MMS Ss as ES AAA nim microcomputer setup panel Workstation number If more microcomputers are connected to the computer each opened software window is marked with different order number of the workstation E g 1 2 3 etc
16. measurement Click on the square with setting value and rewrite with new value Press ENTER on a computer keyboard to confirm MICROCOMPUTER SETUP I 60KG Rep 1 23 10 2013 9 11 41 N on AVG Power AVG Velocity Part AVG Power PEAK Velocity PEAK Power PEAK Force N o Audio Limits o min E filter Partial Percent Velocity m s o o a o on Value of the partial range also shows vertical red line in Velocity Displacement Time graph The range for measurement for partial avg power is from 0 to red vertical line Peak Force measurement has the same range setting as Partial Avg Power lt means the system finds peak force for setting range from O to a certain predefined percent value of the range of motion Default setting is 50 Why Partial AVG Power Sometimes average or peak power is not sufficient parameter for assessment of athlete s qualities in weight training because many athletes in effort to reach maximum value of power are tried to accelerate at the end of movement This way they reach high average and peak power but those parameters misrepresenting results Simply saying it is too late They have high average and peak power value but with low RFD rate of force development And Rate of force development RFD is a key factor in sports performance where explosiveness is required The Partial Average Power will help emphasize RFD 6 5 Save Data If data are collect
17. o e right side of the window The table Group will appear gt DEVICE CONNECTED ON COM26 USB administracion Center RR O a CONNECTED DISCONNECT o MICROCOMPUTER SETUP AVG Power AVG Velocity Part AVG Power PEAK Velocity PEAK Power PEAK Force Datadirectory C Users Marian Documents Tendo Sports Machines Ready y Click Add write down the group name click Save Click Add for next group and again click Save etc If you want delete group select group and click Delete to delete particular group Click Exercise to create exercise database To add or delete the name of the exercise use the same procedure as for Group Click Person to create person in database Recommended format is Last name First name To add or delete person use the same procedure as for Group If new Person is added it is necessary to assign particular group from group list for new Person El Administration Form Group Excersise Person MORE INFO Tendosport e Personal Info If you click on Personal Info the Personal Info window is appear Just fill in the information you want dEl Person Info Person Info First Name omn Last Name Tendoman st Date of Bith 01 28 1980 Height 6 fo Sex Mae Weight 210 pounds Note Metric US Pro Beach volleyball player Close the Administration Cen
18. ound highlight it and remove it from Device Manager to prevent any conflicts during the install 3 Plug the Tendo Computer Bluetooth with USB connector to the computer New hardware wizard should appear if Windows detects the new hardware Using this wizard you should be able to point Windows to the folder containing your drivers either on the CD or the folder containing the files you downloaded If Windows does not detect any new hardware open Control Panel and double click the Add hardware icon to run the hardware detection wizard During the steps you will have an option to tell Windows you have a disk containing the drivers for your new hardware device at this point Windows to the directory containing the drivers for your device Once drivers have been installed reboot the computer 1 Run the Found New Hardware Wizard for Tendo Bluetooth USB Serial to assist you in setting up the new device Click Next to continue Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install a device driver for a hardware device To continue click Next 2 click Next to continue Select the Search for a suitable driver for my device recommand Found New Hardware Wizard Install Hardware Device Drivers Pa t 4 device driver is a software program that enables a hardware device to work with y an operating system This wizard will complete the installation for this devi
19. ter window click Close or X The location of the TENDO Power Analyzer database is in the following directory C Users Documents Tendo Sports Machines Group Exercise Name Database directory is created from filled Administration Form automatically 5 Online mode TENDO Power Analyzer program is online connected to microcomputer 6 1 A connection with Microcomputer Connect the Tendo Microcomputer Bluetooth and Tendo Computer Bluetooth first and then open Tendo Power Analyzer program Program detects COM port number automaticly lf you open Tendo Power Analyzer program first and then plug the Microcomputer Bluetooth and Computer Bluetooth click Refresh on upper right corner of the program and the software find appropriate free COM port DISCONNECTED it Then click Connect lf the communication between the computer and the microcomputer is lost click connect Then open TPA program again and click Connect If still there is not connection or the communication between Computer and Microcomputer is lost close the TPA software and open it again Then click Connect TPA software detects COM Port Number for Tendo Bluetooth SW 4 0 4 HW 03 Bd Mia PEAK Power PEAK Force DEVICE CONNECTED TO mn COM105 USB ready 0 w DISCONNECTED CONNECTED 0 70 kg i DISCONNECT ee No connection or disconnected connected And no COM port detected If the Bluetooth devices are connected and the micro
Download Pdf Manuals
Related Search
Related Contents
地上デジタル防水テレビ 7 型 catálogo - Seminsa DOMEKT REGO 200 - Notice - 2015.indd Chronos CD Bedienungsanleitung (BRJ-906LCD SER Copyright © All rights reserved.
Failed to retrieve file