1. Za input level or counterclockwise to increase the maximum AMX192 input level When gt shipped from the factory maximum AMX192 input level is set to 5 volts Fl 77 ES IN E TOO mme ann SB Maximum analog output level P2 Pot P2 adjusts the maximum analog output level from 0 to 12 volts Voltage meter readings are required to accurately adjust the output levels When shipped from the factory maximum analog output level is set to 10 volts Turn pot clockwise to increase maximum analog output level or counterclockwise to decrease the maximum analog output level Minimum analog output level P3 Pot P3 adjusts the minimum analog output level from 0 to 300 millivolts Voltage meter readings are required to accurately adjust the output levels When shipped from the factory minimum analog output level is set to 0 volts Turn pot clockwise to increase minimum analog output level or counterclockwise to decrease the minimum analog output level Note that minimum analog output setting P3 affects the maximum analog output setting P2 Check both settings if you change either of them DIP switch settings DIP switch settings determine operation mode and select analog output filters See below for DIP switch settings set all unused DIP swit
2. Pass through AMX192 connector pinout 1 Common 2 Clock 3 Clock 4 Analog multiplex 5 Pass through Reset switch Pressing the Reset switch forces the microprocessor to reread DIP switch and number switch settings You must press Reset to activate DIP switch setting changes and to start and stop diagnostic tests Indicator LEDs Status Indicates 15V LED continuous 15 volts power present 15V LED continuous 15 volts power present 5V LED continuous 5 volts power present Data LED continuous Valid data Data LED blinking No data DMX512 termination switch If the Response 96 Out is the last device in a DMX512 D192 or K96 data stream set the DMX512 termination switch On right If you are sending a digital data stream to another interface or dimming device set the DMX512 termination switch Off left For AMX192 operation set DMX512 termination switch Off left Response 96 Out User Manual e Page 5 Potentiometers The Response 96 Out has three potentiometers two analog output pots and an AMX192 input pot Pots are located on the circuit board inside the Response 96 Out Caution AC is exposed when cover is removed AMX192 maximum input level P1 E A Pot P1 adjusts the maximum AMX192 input level Voltage meter readings are required All to accurately adjust levels Turn pot clockwise to decrease the maximum AMX192 ji
3. has an operating range of 90 to 140 volts AC 50 60 hertz with S o nominal voltage at 115 volts It has an external AGC 1 one amp fuse Disconnect power before replacing fuse Consult factory on 240 VAC operation Specifications Dimensions 2 1 H x 9 W x 16 75 D portable 1 75 H x 19 W x 15 D rack mount Weight 7 75 pounds portable 12 pounds rack mount Processing speed 50 hertz Caution AC is exposed when cover is removed Response 96 Out User Manual Page 7 North America 3030 Laura Lane Middleton Wisconsin 53562 e USA e Tel 1 608 831 4116 e Fax 1 608 836 1736 Europe 5 Victoria Industrial Estate e Victoria Road London W3 6UU e Tel 44 181 896 1000 e Fax 44 181 896 2000 Asia Room 1619 20 e 16 F Metro Centre Il e 21 Lam Hing Street Kowloon Bay e Hong Kong Tel 852 2799 1220 e Fax 852 2799 9325 World Wide Web http www etcconnect com Email mail etcconnect com Copyright 1990 96 Specifications subject to change 10861003 Revised 10 96 zT C Electronic Theatre Controls
4. ches in the open position DIP switches are located on the circuit board inside the Response 96 Out Caution AC is exposed when cover is removed Operation mode Set DIP switches 1 and 2 according to chart below to select operation mode System is configured for DMX512 input when shipped from factory Switch 1 Switch 2 GPEN a DMX512 operation Open Open F 1 AMX192 operation Open Closed d D192 operation Closed Open 3 K96 operation Closed Closed Analog output filters Output filters moderate fluctuating input signals Filters slow lamp response to control adjustments therefore experiment with filters to determine the minimum filter needed Set DIP switches 7 and 8 as shown below to select filter System is config ured with no filter when shipped from the factory 78 Switch 7_ Switch 8 ad No filter Open Open dd Small filter Closed Open d y Medium filter Open Closed j j Large filter Closed Closed Page 6 e Response 96 Out User Manual Analog connectors 3 36 Three analog Centronics type connectors each output 32 analog signals Each analog gt ey gt output can drive 10ma with a maximum output of 250ma for the entire board The minimum voltag
5. digit starting dimmer number 01 86 on the number switches and press Reset Chase The Chase test flashes each of the 96 analog dimmers to full intensity in a chase sequence Set number switches to 92 Fade All The Fade All test simultaneously fades all analog dimmers to full intensity and then back down to zero intensity Set number switches to 93 Fade Chase The Fade Chase test fades each of the 96 analog dimmers to full intensity and then back to zero intensity ina chase sequence Set number switches to 94 Selected Output to Full The Selected Output to Full test sets a selected analog dimmer output to full intensity and holds it there Set number switches to 95 and press Reset Then enter analog dimmer number 01 96 All to Percent The All to Percent test sets all analog dimmer outputs to an intensity percentage you specify and holds them there Set number switches to 96 and press Reset Then enter a percentage between 00 and 99 on the number switches Pass Thru Input el 15V 15V 5V Data off On Input connectors Response 96 Out has two 5 pin XLR connectors a male connector for input and a female connector for pass through The Pass Thru port allows you to pass the control signal through the Response 96 Out to other interface or dimming equipment DMX512 D192 K96 connector pinout 1 Common 2 Data 3 Data 4 No connection 5
6. e can be adjusted from 0 to 300 millivolts The maximum voltage can 18 be adjusted from 0 to 12 volts See the section on potentiometers for adjustment information Analog pinouts Connector 1 Pins 1 32 Dimmers 1 32 Connector 2 Pins 1 32 Dimmers 33 64 Connector 3 Pins 1 32 Dimmers 65 96 All Connectors Pins 33 34 Not connected Pins 35 36 Common Optical isolation The Response 96 Out features an optical isolation device Optical isolation creates a N physical break between the Response 96 Out and the DMX512 data link to help prevent accidental high voltage potentials applied to the analog outputs from damaging other equipment on the DMX512 line If you are using the Response 96 Out in AMX192 operation mode see page 6 you must configure the circuit board to bypass the optical isolation feature To bypass optical isolation for AMX192 operation position jumper over both pins A al AMX192 input at location A on circuit board near 96 pin DIN connector All other protocols To enable optical isolation for DMX512 D192 or K96 operation position jumper over only one pin at location A on circuit board AC power The Response 96 Out
7. rESPONSE 96 OUT User Manual reSpONSE 96 OUT Analog outputs Number switches DMX512 termination switch Indicator LEDs Reset switch Fuse Power switch Power connector DMX512 AMX192 D192 K96 Input DMX512 AMX192 D192 K96 Pass Thru 000008 LO The Response 96 Out interface allows you to convert 96 DMX512 AMX192 D192 or K96 dimmer signals to analog signals This manual provides information on all Response 96 Out controls connectors and indicators To use Response 96 OUT follow these steps 1 Remove cover and set DIP switches to select desired operation mode see page 4 2 Return cover to Response 96 OUT housing 3 Plug power cable into the power connector and a 120 VAC outlet and turn power switch On 4 Insert input cable input into the connector If necessary insert output cable into the Pass Thru connector 5 Insert 36 pin analog dimmer cables in analog output connectors 6 Set number switches to select starting analog dimmer output number see page 2 7 If Response 96 OUT is the last device in a DMX512 D192 or K96 data link set DMX512 termination switch On right In AMX192 mode leave DMX512 termination switch Off left 8 Press Reset after all options are adjusted to desired settings See following pages for filter and potentiometer settings and additional information on switch functions and settings Note When data flow is interrupted all outputs fade to ze
8. ro percent after approximately four minutes Caution AC is exposed when cover is removed Response 96 Out User Manual Page 3 For starting output 1 7 13 19 25 31 37 43 49 55 61 67 73 19 85 91 97 103 109 115 121 127 133 139 145 151 157 163 169 175 ae ae E E Page 4 Response 96 Out User Manual Entering starting analog dimmer number The rotary number switches allow you to set the dimmer number for the first analog output The remaining 95 analog outputs are consecutively numbered from the number you enter Refer to the accompanying chart to determine number switch setting for the desired starting analog output number You must press Reset after entering a new address setting Performing diagnostic tests Five diagnostic tests are provided on the Response 96 Out each is described below To run a test follow these steps 1 Enter the two digit test number on the rotary number switches See below for test numbers and descriptions 2 Press Reset to start test 3 Adjust the rate at which the test runs by setting the right number switch between 0 and 9 Test pauses when switch is set to 0 test runs at its maximum rate when switch is set to 1 and at its minimum rate when switch is set to 9 4 To stop test enter a valid two