1.   e To delete a Tare value  press  0 T  when the pan is empty     6 3 WEIGHING A SAMPLE    To determine the weight of a sample  first tare the empty container if it is to  be used and then place the sample in the container  The display will show the  net weight of the sample and the unit of weight currently in use        e 7 0 7 0     A Jt Ui             9    Adam Equipment Company 2012    6 4 PARTS COUNTING    If parts counting is enabled  See section 7 4 in the full manual  it is possible to  count parts using a sample of the parts to determine an average piece  weight     e  f using an empty container  place the container on the top pan  and press  0 T  to zero the display  Press the  PCS  key to enter  parts counting mode     e The scale will show    P 10     Change the sample size to the desired  quantity by pressing the  PCS T1 key  It will cycle through the  options  10  20  50  100  200 and back to 10     e Place the nominated sample size into the container and press   0 T   The sample number should match the sample amount  options available for parts counting  i e   10  20  50  100 or 200  pieces     e The display will now show the amount of parts in the container   and as more parts are added the display will increase to show the  number of parts in the container at that time   PCS      Pressing the  Unit  lt   key will display the net weight  PCS and kg   pressing  it a second time will display the unit weight  g pcs   and the third time will  display the count aga
2.   is pressed the display will first show    Fun    1  for  Check weighing parameters     e Press either the  Func C  key or the  PCS M  to advance  through the groups    Fun    1     Fun    2         Fun    3    and    Fun 4    Press  0 T  to enter the desired group of parameters     e When in one of the sections press  Print M  Esc  to return to  the group    Fun    T If you press  Print M  Esc  again  the scale  will exit the User Parameter section and return to normal  weighing     Complete details of all parameters can be found in of the full version of the  user manual     11    Adam Equipment Company 2012    8 0 BATTERY OPERATION    The scales can be operated from the battery if desired  The  battery life can be up to 70 hours depending on the load cells and  how the backlight is used        battery symbol is shown on the display which indicates the  current charge of the battery  3 bars means fully charged  When  just the outline of the battery and no bars are visible the battery  needs to be re charged     To charge the battery  simply plug the adaptor into the mains  power  and also into the input connector on the rear of the  Indicator marked DC 12V  The scale does not need to be turned  on     The battery should be charged for 12 hours to reach full capacity     Near the display is an LED to indicate the status of battery  charging  When the scale is plugged into the mains power the  internal battery will be charged  If the LED is green the battery has  a full char
3.  Function parameters of the scale     A secondary function  C  is to act as a clear key when  clearing an accumulated total           Sends the results to a PC or a Printer using the RS   232 interface  It also adds the value to the  accumulation memory if the accumulation function is  not automatic     A secondary function  ESC  is to return to normal  operation when the scale is in a Parameter setting  mode                       To switch the Indicator on or off    The WARRIOR will store the weighing unit and the  check weighing values currently in use if power is  powered off  These will be re called when the Indicator  is next powered on       5 0 DISPLAYS    The LCD display will show a value as well as the unit currently being used  In  addition the LED   s above the display will show when a weight is below  inside  or above the check weighing limits     Low OK High                    gt  gt  0   r sf es ee  Je fs ff es ff ce ff ff mf 100  CN       Coro   SA Hold   Uhr   kg    g Pcs  M Ib oz    I          Other symbols will show when a weight has been tared  NET   the scale is at  zero and stable  if a value has been stored in memory  or when the animal  weighing function has been enabled  A battery symbol will show the state of  charge of the internal battery     7    Adam Eguipment Company 2012       6 0 OPERATION  6 1 ZEROING THE DISPLAY    e You can press the  0 T  key at any time to set the display to zero   This will usually be when the platform is empty  When the 
4.  O O O een 16  WARRANTY INFORMATION tege o odnosn   17       Adam Equipment Company 2012    1 0    INTRODUCTION    The WARRIOR series provide accurate  fast and versatile general  purpose type weighing scales with parts counting  percentage  weighing and check weighing functions     The WARRIOR has LED   s next to the display to indicate when a  weight is below the low limit  in between the limits or above the  high limit  These can work in conjunction with an audible alarm for  check weighing as well as the display showing LO  OK and HI     The WARRIOR is supplied with a RS 232 bi directional interface  and real time clock  RTC      The WARRIOR has a sealed keypad with colour coded  membrane switches  a large easy to read liquid crystal display   LCD  and a green backlight     Included functions are automatic zero tracking  semi automatic  tare and an accumulation facility that allows the weight to be  stored and recalled as an accumulated total     1    Adam Equipment Company 2012                                                                2 0 SPECIFICATIONS  Model   WSK 8 WSK 16 WSK 32 WBK 32 WBK 75  WSK 16a WSK 35a WSK 70a WBK 70a WBK 165a  Maximum  Capacity 8000g 16lb 16kg 35lb 32kg 70lb 32kg 70lb 75kg 165lb  Readability 0 5g 0 0011b 0 001kg 0 0021b   0 002kg 0 005Ib   0 002kg 0 005lb   0 005kg 0 011b  Resolution 1 16000 1 16000 1 16000 1 16000 1 15000  Pr 19 0 002lb       0 002kg 0 004Ib   0 004kg 0 01lb   0 004kg 0 01lb    0 01kg 0 021b  Linearity   1g 0 0021b 0 002
5.  balances   Mechanical Scales    Counting Scales    Digital Weighing Check weighing Scales   High performance Platform Scales   Crane scales     Health and Fitness Scales    Retail Scales for Price computing    For a complete listing of all Adam products visit our website at www adamequipment com                Copyright by Adam Equipment Co  Ltd  All rights reserved  No part of this publication may be  reprinted or translated in any form or by any means without the prior permission of Adam Equipment     Adam Equipment reserves the right to make changes to the technology  features  specifications and  design of the equipment without notice     All information contained within this publication is to the best of our knowledge timely  complete and  accurate when issued  However  we are not responsible for misinterpretations which may result from  the reading of this material     The latest version of this publication can be found on our Website     www adamequipment com       Adam Equipment Company 2012    
6. SES ADAM O  Adam Equipment    WARRIOR SERIES    USER MANUAL       Adam Equipment strives to be more environmentally focused and uses recycled materials and  environmentally friendly packaging where possible  As part of this initiative we have developed a short  manual that uses less paper and ink to describe the main functions of your new Adam product  A complete  version is available at www adameguipment com  Thank you for your support of Adam Eguipment      P N  3136611622   Revision B  April 2012     Adam Eguipment Company 2012       Adam Equipment Company 2012    CONTENTS    10  INTRODUCTION MR O O ecg I 1  P  V 2038110 C R V rs in tes 2  5 0   INSTALLATION PA P P e 4  SCH   UNPACKING tee ia o on 4  E TEE 4  3 3 SETTING UP THE SCALES menus  5  410 KEY DESCRIPTIONS erte reueg ee EE 6  BOE  DS AP CAD EE RER O ae 7  GO  EC 8  6 1    ZEROING THE DISPEAY st   not a nu evi Ne cn demie 8  Get RING ht a O ote O ne O rent Me 8  6a EIERE EE 9  64  PARIS COLNTING 3 manne ie tue Seen ls urate ne AM NES 10  Gb REENEN EE 10  6 6  SAOCUMULATE   TOTAL eu A ene ue eos tenants 11  6 7    PERCENTAGE  WEIGHING aere 11  66  ANIMAL  Dynamic  RIESEN 11  To USER PARAMETERS un ee 0a nn R ena 11  807 ERR EE 12  90 4 RS 232 TERA CE nee nm gra O 12  D  INPUT COMMANDS FORMAT eet reiege lol ln 13  10 07 RELAY INTERFACE  Lutin nr De nes deu nt dc bound 13  11 0 CALIBRATION eege 14  12 0      SERVICE PARAMETERS cation on ooo or lo os ee 15  12 1 USING THE SERVICE PARAMETERS vvn 15  13 0 ERROR CODES RR R
7. accumulation memory  if the accumulation function is not set to automatic                 10 0 RELAY INTERFACE  The indicator is supplied with drivers to control external relays  The drivers  could be used to control a number of different relays depending upon the  users needs  The relay drivers are isolated outputs requiring the use of an  external power supply and the relay option kit     See of the full version of the user manual for complete details     13    Adam Equipment Company 2012    11 0    CALIBRATION    The scale can be calibrated using the following procedure  To enter this  procedure it is necessary to use Func 4 which is accessible using the   Func C  key as described in section 7 4 in the full manual  or by using the  passcode access as described in section 12 0     The scales calibrate using either metric or pound weights depending on the  weighing unit being used before calibration  The display will show either  kg   or  lb  to identify the weights expected     PROCEDURE    Enter the calibration section using Func 4  C8 CAL or using the  passcode as described in section 12 0     The display will show  unLoRd      Remove any weight from platform and when the stable symbol is  on press  0 T      The display will show  Ld  then    0000XK which shows the last  calibration weight used  Place this calibration weight on the scale  and press the  0 T  key  If the weight you put on the scale does  not match the value displayed  press the  Func C  key to clear the  v
8. al     15    Adam Equipment Company 2012                               13 0 ERROR CODES  ERROR   DESCRIPTION   SUGGESTIONS  CODES    oL      Over range Remove weight from the scale   If the problem persists contact your dealer or Adam  Eguipment for assistance   Err 1 Time Setting   Enter time using correct format and reasonable  Error values  Format  hh mm ss  Err 2 Date Setting   Enter date using correct format and reasonable  Error values  Format  yy mm dd  Err 4 Zero Setting   The scale was outside the normal zero setting  Error range either when it was turned on  or when the   Zero  key was pressed   Remove weight from the scale and try re zeroing  again   Use the  0 T  key to set the display to zero value   If the problem persists contact your dealer or Adam  Eguipment for assistance   Err 6 A D out of range   The values from the A D converter are outside the  normal range   Remove the weight from the scale if overloaded   Make sure the pan is fitted correctly   Indicates the load cell or the electronics may be  faulty   If the problem persists contact your dealer or Adam  Equipment for assistance   Err 9 Check weigh Shown if the low limit is set higher than the current  limits error high limit  Reset High limit or change the low limit   FAIL Calibration Improper calibration  should be within   10  of the  error  factory calibration   The old calibration data will be          retained until the calibration process is complete   If the problem persists contact your deale
9. ale then use the  Unit  lt   key and  PCS    N  key to set the correct  value  When it is correct press  0 T      If the calibration is acceptable the scale will run a self test during  which the calibration weight should be removed  If an error  message    FAIL L  is shown try calibration again as a disturbance  may have prevented a successful calibration     After calibration the scale should be checked to verify the calibration is  correct  If necessary repeat the calibration making sure that the scale is  stable before accepting any weight     14    Adam Eguipment Company 2012    12 0 SERVICE PARAMETERS    The scales will allow entry to the parameters if the  Tare  key is pressed  during the power on cycle  The passcodes work as explained earlier    In this case the display will show the passcode request screen     P         To  continue enter a passcode as described below    Entering passcode 0000 will allow calibration as shown in section 11     Entering 1000 will allow access to a limited set of parameters described in  section 12 1     12 1 USING THE SERVICE PARAMETERS    Press the  0 T  key during the display countdown when turning on     When  P is displayed  enter the number 1000 using the  Uni    lt   and   PCS T  keys and then press  0 T      The display will show the first parameter called    F4 Int      To select another parameter press the  PCS T  key which will advance    through the parameters available  Full details are in the full version of the  user manu
10. ge  If it is red the battery is nearly discharged and yellow  indicates the battery is being charged     9 0 RS 232 INTERFACE    The WARRIOR indicator is supplied with bi directional RS 232 interface as  standard  The scale when connected to a printer or computer outputs the    weight with    the selected weighing unit through the RS 232 interface     Specifications     RS 232 output of weighing data  ASCII code    9600 Baud  user selectable     8 data bits    No Parity       12    Adam Equipment Company 2012    The RS 232 serial interface is located inside the housing  access is gained by  removing the 8 x case screws whereby connections can be made to COM 1  as shown below     RXT Received Data  TXT Transmitted Data  GND Signal Ground    The cable used should be routed through the gland marked RS 232 on the  case and tightened securely to ensure a watertight connection is made     The scale can be set to print text in English  French  German or Spanish   See the RS 232 parameters section for details    9 1 INPUT COMMANDS FORMAT    The scale can be controlled with the following commands  Press the  Enter   key of the PC after each command        T lt cr gt  lt lf gt    Tares the scale to display the net weight  This is the same as  pressing  0 T         Z lt cr gt  lt lf gt    Sets the zero point for all subsequent weighing  The display  shows zero        P lt cr gt  lt lf gt    Prints the results to a PC or printer using the RS 232  interface  It also adds the value to the 
11. in  PCS      e Press the  PCS  M  key to return to normal weighing  Press the   PCS      key again to start counting a different sample     6 5 CHECK WEIGHING    Check weighing is a procedure where the LED   s come on  and if enabled  an  alarm to sound  when the weight on the scale meets values stored in  memory  The memory holds the last values for a high and a low limit when  the power is turned off  The user can set either one limit or both  see the full  version of the user manual for details of the check weighing function     10    Adam Equipment Company 2012    6 6 ACCUMULATED TOTAL    e The scale can be set to accumulate manually by pressing the   Print M  Esc  key  or automatically when a weight is removed  from the scale  See the Section 7 3 of the full manual for  details     6 7 PERCENTAGE WEIGHING    The scale can be set to perform percentage weighing  See Section 7 2 of the  full version of the user manual for complete details     6 8 ANIMAL  Dynamic  WEIGHING   The scale can be set to animal  dynamic  weighing for weighing any items  that are unstable or may move  See Section 7 4 of the full version of the user  manual for complete details     7 0 USER PARAMETERS    Pressing the  Func C  key during normal operation allows the user to access  the parameters for customizing the scale  The parameters are split into 4  groups     1  Check weighing parameters    2  Percentage and Animal Weighing Functions  3  RS 232 parameters   4  Scale parameters    e When  Func C
12. kg 0 0041b   0 004kg 0 011b 0 004kg 0 011b 0 01kg 0 021b  jus 250mm x 250mm  9 8in x 9 8in 300mm x 400mm  11 8in x 15 7in  SC or g Kg  Lb  Lb oz   Newtons Ounces  easure  m 2 3 Secs  ime  sue 10    to  400   32F to  104F  emperature  Power S  ppi   6v 4 5Ah battery  ppy 12VDC 800mA External adaptor  Calibration External  Calibration User Selectable  Mass  Display Backlit Green display 40mm high digits with capacity tracker  S   304 Stainless steel housing IP66 rated  ousing             Adam Equipment Company 2012                                                                Model   WFK 75 WFK 150 WLK 150  WFK 165a WFK 330a WLK 330a  Maximum  Capacity 75kg 165lb 150kg 330lb 150kg 330lb  Readability 0 005kg 0 011b 0 01kg 0 021b 0 01kg 0 021b  Resolution 1 15000 1 15000 1 15000  Repeatability   Std Dev  0 01kg 0 021b 0 02kg 0 041b 0 02kg 0 041b  Linearity   0 01kg 0 021b 0 02kg 0 041b 0 02kg 0 041b  on 400mm x 500mm  15 7in x 19 7in 450mm x 600mm  17 7in x 23 6in  Units of    Measure g Kg  Lb  Lb oz   Newtons Ounces  Stabilization  Time 2 3 Secs  Nay 10    to 440      32F to  104F  emperature  Power Suppl   6v 4 5Ah battery  PRY 12vDC 800mA External adaptor  Calibration External  Calibration User Selectable  Mass  Display Backlit Green display 40mm high digits with capacity tracker  SE 304 Stainless steel housing IP66 rated  ousing       3    Adam Equipment Company 2012       3 0 INSTALLATION    3 1 UNPACKING    The WARRIOR scales have already been adjusted to work with a platf
13. n used for protection     e Fix the pillar to the base bracket fitting using the screws provided    e Adjust the viewing angle of the Indicator to the ideal position and  tighten the 2 x locking handles     e Level the scale by adjusting the five feet on the WSK WBK or the  four feet on the WFK WLK  If the scale rocks re adjust the feet        e Attach the power to the indicator and press the  On Off  key  The  software revision number will be displayed followed by a self test  showing all digits before the zero is displayed along with the unit  of weight that was last used     5    Adam Equipment Company 2012    4 0 KEY DESCRIPTIONS        H  ADAM WARRIOR    Low OK High    CH          ESC  ej e       Used to reset the display to zero     Tares the scale  Used to deduct and store the weight  currently on the scale if it is not required as part of the  final weighing result        A secondary function     l is of an    Enter    key used  when setting up a value for the Parameters        Selects parts counting  Used to set the sample  quantities while parts counting    A secondary function    is of incrementing the active  digit when setting a value for Parameters           Selects the weighing unit to be displayed from those  which are enabled  See parameter S1 in section 7 4 in  the full manual        A secondary function    is to move the active flashing  digit to the left when setting values for Parameters           6    Adam Equipment Company 2012          o    Selects the
14. nt to insure compliance with the  pertinent RF emission limits governing this device     Changes or modifications not expressly approved by Adam Equipment could void the user s authority to  operate the equipment                 WEEE COMPLIANCE    Sealed Lead Acid  Battery   Must be recycled  Properly       Any Electrical or Electronic Equipment  EEE  component or assembly of parts intended to be  incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or  disposed using techniques that do not introduce hazardous substances harmful to our health or the  environment as listed in Directive 2002 95 EC or amending legislation  Battery disposal in Landfill Sites is  more regulated since July 2002 by regulation 9 of the Landfill  England and Wales  Regulations 2002 and  Hazardous Waste Regulations 2005  Battery recycling has become topical and the Waste Electrical and  Electronic Equipment  WEEE  Regulations are set to impose targets for recycling                 Adam Equipment Company 2012             ADAM EQUIPMENT is an ISO 9001 2008 certified global company with more than 35  years experience in the production and sale of electronic weighing equipment     Adam products are predominantly designed for the Laboratory  Educational  Health and  Fitness  retail and Industrial Segments  The product range can be described as follows      Analytical and Precision Balances   Compact and Portable Balances   High Capacity Balances    Moisture analysers  
15. orm  and have been configured for this application  The platform and indicator  have been calibrated as a pair and must be used together     3 2 LOCATING       ZE e The scales should not be placed in a location that  will reduce the accuracy     om       e Avoid extremes of temperature  Do not place in  direct sunlight or near air conditioning vents        e Avoid unsuitable tables  The table or floor must be    rigid and not vibrate          e Avoid unstable power sources  Do not use near    large users of electricity such as welding equipment  or large motors        e Do not place near vibrating machinery     ta            ke  D  e Avoid high humidity that might cause condensation   2 Avoid direct contact with water  Do not spray or  4 immerse the scales in water    e Avoid air movement such as from fans or opening  doors  Do not place near open windows or air   conditioning vents    L e Keep the scales clean  Do not stack material on the  scales when they are not in use                 4    Adam Equipment Company 2012    3 3 SETTING UP THE SCALES    e Remove the Indicator from its box and fix it to the U shaped  bracket using the 2 x fixing handles  Take the Indicator and place  it onto the pillar ensuring the slack cable is pushed inside  Fix the  Indicator to the pillar using the screw provided     e Remove all upper internal packaging  place the pillar into the base  bracket fitting and remove the complete machine from the box   Remove any plastic bags that may have bee
16. r or Adam  Equipment for assistance        16    Adam Equipment Company 2012       WARRANTY INFORMATION       Adam Equipment offers Limited Warranty  Parts and Labour  for the components failed due to defects  in materials or workmanship  Warranty starts from the date of delivery     During the warranty period  should any repairs be necessary  the purchaser must inform its supplier or  Adam Equipment Company  The company or its authorised Technician reserves the right to repair or  replace the components at any of its workshops depending on the severity of the problems  However   any freight involved in sending the faulty units or parts to the service centre should be borne by the  purchaser     The warranty will cease to operate if the equipment is not returned in the original packaging and with  correct documentation for a claim to be processed  All claims are at the sole discretion of Adam  Equipment     This warranty does not cover equipment where defects or poor performance is due to misuse   accidental damage  exposure to radioactive or corrosive materials  negligence  faulty installation   unauthorised modifications or attempted repair or failure to observe the requirements and  recommendations as given in this User Manual  Additionally rechargeable batteries  where supplied   are not covered under warranty     Repairs carried out under the warranty does not extend the warranty period  Components removed  during the warranty repairs become the company property     The 
17. statutory right of the purchaser is not affected by this warranty  The terms of this warranty is  governed by the UK law  For complete details on Warranty Information  see the terms and conditions  of sale available on our web site              17    Adam Equipment Company 2012       Adam Equipment Company 2012       Adam Equipment Company 2012          CE    Manufacturer   s Declaration of Conformity    This product has been manufactured in accordance with the harmonised European standards  following the  provisions of the below stated directives     Electro Magnetic Compatibility Directive 2004 108 EC  Low Voltage Directive 2006 95 EC  Adam Equipment Co  Ltd   Maidstone Road  Kingston     Milton Keynes  MK10 OBD  United Kingdom          FCC COMPLIANCE    This equipment has been tested and found to comply with the limits for a Class A digital device  pursuant  to Part 15 of the FCC Rules  These limits are designed to provide reasonable protection against harmful  interference when the equipment is operated in a commercial environment  The equipment generates   uses  and can radiate radio frequency energy and  if not installed and used in accordance with the  instruction manual  may cause harmful interference to radio communications  Operation of this  equipment in a residential area is likely to cause harmful interference in which case the user will be  required to correct the interference at his own expense     Shielded interconnect cables must be employed with this equipme
18. zero  point is obtained the display will show an indicator for zero     Low OK High       zs UT  UUU LA   o          wk     sl III I l I    100        e The scale has an automatic re zeroing function to account for  minor drifting or accumulation of material on the platform   However you may need to press the  0 T  key to re zero the scale  if small amounts of weight are shown when the platform is empty     6 2 TARING    e Zero the scale by pressing the  0 T  key if necessary  The     ZERO    indicator will be ON     Low OK High      UT                e Place a container on the platform and a value for its weight will be  displayed        Adam Equipment Company 2012    e Press the  0 T  key to tare the scale  The weight is deducted and  stored as the tare value leaving zero on the display  The    NET     indicator will be ON and as a product is added only the net weight  of the product will be shown  The scale could be tared a second  time if another type of product was to be added to the first one   Again only the weight that is added after taring will be displayed     Low OK High    s nnnn  VUV    100              ell         e When the container is removed a negative value will be shown  If  the scale was tared just before removing the container this value  is the gross weight which includes the container and the entire  product it contains  The    ZERO    indicator will be on to indicate  that the platform is back to the same condition as it was when  zero was last set   
    