212i Wiring Diagrams and Specifications

image

Contents

1. EEEE V V NC C NO To Alarm Panel V V NC C NO V V NC C NO S __S I z p ferminals S 12 Volts eng Door DD 12 Volts Fail Secure To Alarm Panel 6040400 Rev 1 2 6040400 Rev 1 2
2. Board box with the keypad sate manne Transom Electromagnetic Note Diagram shows 12 24VDC Door Lock output 2 as and example Wht Bik Fail Safe Basic Access Control with an Electric Shunting a Normally Closed Zone and Arming and Disarming a Door Strike Wiring a Request to Exit Device REX Typical Alarm Control Panel To control the LED s externally cut the four traces in the box underneath connector J1 Before connecting the alarm panel s LED sceeeeeuse 0000000000 eeceseeeee control lines to J1 verify the traces are cut To eoccccccce 0000000000 eoccccccce g verify measure continuity between the end of the wire on the wire harness and the square pad on the circuit board below the box Request to Exit Request to Exit Device REX corresponding to the wire you re measurin Device REX TOTTI NTA i j TTL j4 J A y4 Permanent damage to the keypad may LJ e White Black White Yellow Red C meee meee Cut traces here zese LEDs Operate result if voltage is connected to J1 when to control LED s gt on 12VDC thet t t externally e traces are not Cut Alarm Control Panel Wht Orange 10 1 Green LED OLCIIIIIII IJ Wht Orange BSSSSSSSSS Green LED Asi Red LED Red LED
3. additional 30mA for each relay energized OUTPUTS Main Relay 5 Amp Form C 24VDC with 10 Amp surge Outputs 2 3 and 4 are 50mA negative voltage outputs ENVIRONMENTAL TEMPERATURE 20 F TO 130 F 28 C TO 54 C Indoor Only Packing Checklist 212i Keypad 10 Conductor Wire Harness 4 Conductor Wire Harness 1 1 Slotted screws 2 Security Screws 2 Transorb 1 Features amp Programming Guide Warranty Guide 6040400 Rev 1 2 6040400 Rev 1 2 a Basic Access Control with an Wiring an Accessory Relay Wiring to 250 Printer Interface 293 Auxiliary Relay Board Electromagnetic Door Lock i y For a Hard Copy Audit Trail B K in Keypad Active REI Print Live Only elwi Output 2 K out Mormaleopen 0000000000 REX Input S200eeeeoee REX Input Accessory Relay HUEUEDOEONEONE m Output 3 of Normally Open ATTN amann Relay 2 R Request to Exit ETA Device REX MNM J1 mini ip switch selection Output 4 Relay 3 for 12 or 24 Volt TTT TTT j4 a operation Switch meee 12V 24V all 3 to operation cc voltage The IEI 293 plug on relay board converts Wht Orange voltage outputs to 1 Amp Form C relays Note A and provides screw EEEE separate power terminals for all inputs V V NC C NO supply must be and outputs V V NC C NO used for the The 293 fits into a locking device standard 2 electrical ee K d Circuit
4. 1 See the diagram for details Also the voltage selection jumper on the main circuit board is no longer required To prevent electrical kick back voltage from damaging the keypad when using an electrical locking device you MUST install the transorb as close as possible to the lock Wire the transorb in parallel with the lock power terminals Also to avoid ESD electro static discharge from interfering with the operation of the keypad ground the negative terminal of the keypad to earth ground If you cannot ground the power supply then you must ground the keypad housing IEI recommends using a filtered and regulated power supply 212i Wire Harness White Not Used Wht Blue Output 3 V 50mA sink Wht Red Output 2 V 50mA sink Orange Output 4 Panic V 50mA sink Brown REX Input Wht Orange REX Input Wht Black K in Keypad Active Wht Yellow K out Black Ground Output Only Red V Output Only Note The red wire is the same voltage as your power supply If you re using AC this voltage is rectified DC SPECIFICATIONS MECHANICAL BOARD DIMENSIONS 1 80 W x 2 845 H x 1 125 D ELECTRICAL VOLTAGE 12 24 Volts AC DC No Jumper Required CURRENT 8mA 12VDC typical 35ma with relay energized 16mMA 24VDC typical 45ma with relay energized 21mMA 12VAC typical 74mA with relay energized 43mMA 24VAC typical 91mA with relay energized Note Keypads using the 293 Relay Board need an
5. Wiring Two Keypads to Control a Single Door Keypad 1 TET j4 10 1 ere V V NC C NO 0000000000 12 24VDC Keypad 2 PU LET Connect Normally Open to TUT TT TT j4 White Orange 0000000000 f Connect Common to Brown Relay V V NC C NO Transom Electromagnetic 12 24VDC Hee Door Lock Fail Safe The diagram above shows how to connect two keypads to control a single door Entering your code on keypad 2 unlocks the maglock directly When you enter your code on keypad 1 it triggers the REX input of keypad two which unlocks the door Please note that user codes must be programmed into both keypads INTERNATIONAL ELECTRONICS INC 427 TURNPIKE STREET CANTON MA 02021 USA 800 343 9502 781 821 5566 781 821 4443 FAX WEB ADDRESS www ieib com E i International Electronics Inc 212i Wiring Diagrams and Specifications 212i Circuit Board Sssssseoss TTL LL j4 ieee 10 1 NO 00006666 Relay eocce V V NC C NO TECHNICAL NOTES This product was re designed using a new manufacturing technology which changed the physical appearance of the keypad electronics The LED s changed to surface mount chip LED s mounted on bottom of the circuit board which eliminates the need for the wire harnesses Itis also possible to control the red and green chip LED s externally with an alarm panel for example by using connector J