Home
CRY-AC TrackerCam - Brymill Cryogenic Systems
Contents
1. non CRYOGENIC SYSTEMS CRY AC TrackerCam INSTRUCTIONS FOR USE www brymill com March 2015 Page 1 of 23 TABLE OF CONTENTS Section 1 2 3 10 Section 1 Table of Contents Title Table of Contents Read Before Use Indications For Use 3 1 Use of Content 3 2 Handling Warning 3 3 Warranty CRY AC TrackerCam Introduction 4 1 Package Contents 4 2 Before Use 4 2 1 Battery Installation Instructions 4 2 2 Mini SD Memory Card 4 2 3 Reset Button CRY AC TrackerCam First Time Sep Up Instructions 5 1 Setting the Clock 5 2 Setting the Timeout 5 3 Understanding the Display Functions of the Main Screen 5 4 To Begin Use Recording Process 6 1 Additional Lighting 6 2 Recording Process 6 3 Transferring the Recordings to a Computer Routine Maintenance 7 1 Care amp Maintenance 7 2 Cleaning 7 2 1 LCD Display 7 3 Batteries 7 3 1 Battery Replacement 7 3 2 Battery Safety and Disposal Instructions 7 4 Storage 7 5 User Self Test Troubleshooting 8 1 CRY AC TrackerCam Troubleshooting 8 1 1 Faults Associated to Power 8 1 2 Faults Associated to the Display 8 2 Camera Focus 8 3 CRY AC Troubleshooting Technical Specification 9 1 Performance Requirements 9 2 Power 9 3 User Interface 9 4 Operating Modes 9 5 Software 9 6 Camera 9 7 Transport and Storage 9 8 Normal Operating Conditions Chart of Benign Lesions Explanation of utilized Symbols Contact Information D O O O O c pro Page 2
2. 18 09 AM LILER REC button changes to STOP and the MENU button changes to PAUSE Elapsed time begins counting Record the Patients information for 2 to 3 seconds then press PAUSE When the camera is recording the PAUSE button can be pressed at any time during the procedure The Elapsed time will continue to count but the Camera is NOT recording STOP If STOP is pressed at any time this stops the recording process The Temperature Sensors continue to operate 12 18 09 AM Reposition the camera and Blue Beams to the lesion to be treated Press RESUME and the camera will continue recording Focus the 2 Blue beams together to ensure correct focal length and focus Begin the Freeze Thaw Cycle 12 18 09 AM Page 14 of 23 INSTRUCTIONS FOR USE The Upper section of the Screen and the 2 Blue Beams change to GREEN when the temperature of the Ice Ball reaches 0 C The Lights have also been turned ON Continue the Freeze Thaw Cycle STOP rey PAUSE 123609 AM LOU The Upper section of the Screen and the 2 Green Beams change to RED when the temperature of the Ice Ball reaches Tmin If Mode 1 is set then an Audible Beep will sound every second the RED is maintained If the Ice Ball temperature goes above Tmin the Screen and Beams will change to GREEN cob Below Tmin time indicator will also begin Continue the Freeze Cycle for the require Freeze Time After the required Freeze time at Tmin has been achieve press STOP The readin
3. DC Charging Port and Power down the CRY AC TrackerCam See section 9 2 START Not Charging Problem No or Low Power X The battery has been on charge for the required time but charge Drymin indicator is showing no green segments Solution Reset the unit and try recharging See section 7 1 2 If problem START persists replace the battery See section 6 3 1 o Ss a Low Battery If the problem with the CRY AC TrackerCam is not resolved by checking or replacing the battery then the complete device must be returned for repair Page 18 of 23 INSTRUCTIONS FOR USE 8 1 2 Faults associated with the Display Problem Display Error The display is not reading or functioning correctly Solution If there appears to be a problem with the display or any of the functions of the CRY AC TrackerCam then reset the software by pressing the reset button located behind the center of the 3 holes located under the Tracker badge This can be done by opening an end of a paperclip and inserting it into the center hole Caution do not press hard Pressing the reset will shut the unit down and will require the double press of the power button to restart it If the problem with the CRY AC TrackerCam Display or functions is not resolved by doing a Reset then the complete device must be returned for repair 8 2 Camera Focus The Camera Focus is a Factory Setting and cannot be adjusted by the End User If the images appear to be out of focus t
4. ON OFF SLEEP MODE Product bearing this symbol may not be disposed of together with general household waste but instead requires separate disposal according to local provisions European Waste Electrical and Electronic Equipment Directive WEEE wo 0 ec REP European Authorized Representative EC Page 22 of 23 Brymill CRYOGENIC SYSTEMS World Leader in Design and Manufacture of Cryosurgical Equipment since 1966 ual Brymill Cryogenic Systems 105 Windermere Avenue Ellington CT 06029 USA Tel 860 875 2460 In the USA 1 800 777 2796 Fax 860 872 2371 Web www brymill com Email brymill brymill com s ue European Authorized Representative Brymill Cryogenic Systems UK Ltd Unit 4 Basepoint Centre Stroudley Road Basingstoke RG24 8UP UK Tel 44 0 1256 841045 Fax 44 0 1256 350330 Email sales brymilluk com CE 0120 Page 23 of 23
5. Unit ant 2 x 3 4 x 20g Straight Needle Instructions for Use CRY AC CRY AC 39 Instructions for Use CRY AC TrackerCam Product Codes to Re order spares or Replacements Mini SD Memory Card with Adapter Code TC SD Heplacement Rechargeable Battery Code TC BATT Replacement Charger Code TC CHARGER 3 4 x 20g Straight Needle Code 107 20 Available direct from Brymill or from an authorized Brymill dealer Page 6 of 23 INSTRUCTIONS FOR USE 4 2 BEFORE USE CAUTION A Do not under any circumstances use any other battery than the one designed for this unit Doing so could result in damage to the unit Also do not under any circumstances use any other charger than the one supplied with the unit 4 2 1 BATTERY INSTALLATION INSTRUCTIONS The CRY AC TrackerCam is fitted with a custom NiMH rechargeable battery that has been fully charged prior to dispatch but requires final connection and charging as follows 1 Place the CRY AC TrackerCam onto a firm surface with the spray outlet pointing away from you Place one hand on the TrackerCam nose 2 Place your other hand neat the yellow label attached to the blue and white top assembly 3 Carefully pull apart using a slight twist away motion Use extreme caution not to pull off the internal ribbon cable 4 Plug the red and black battery cable into the connector located on the bottom right of the ribbon cable When replacing the bat
6. is located behind the Center Hole of the 3 holes just below the Tracker Badge Reset Button Please refer to the Troubleshooting Section to for explanations of when to operate the Reset Button Page 9 of 23 5 CRY AC TrackerCam First Time Set Up Instructions The following is a step by step screen by screen process that needs to be applied to use the lull functions of the CRY AC TrackerCam FACTORY SETTINGS Tmin 1 C Timeout 300s Clock 2 North American EST Eastern Standard Time or UTC 5 hours Mode 1 Date Current Camera Focus Fixed Press the ON OFF Power Button twice There will be 1 audible beep The following screen sequence will appear etn Bin Cryogenic Systems START This is the first screen to appear This screen appears after This screen will appear when the every time the Unit is turned on approximately 2 3 seconds software has finished loading After approximately 1 second the A Blue line also appears in the screen will go blank bottom left of the screen This The time is displayed on the bottom indicates that the software is being left and the Battery indicator is loaded As it progresses then the displayed on the bottom right of the blue line extends to the right of the screen screen This takes approximately 10 15 seconds 5 1 SETTING THE CLOCK AND DATE The clock and date information is part of the information displayed on the screen and also appears in the video clip an
7. the CRY AC TrackerCam The CRY AC TrackerCam is not a substitute for the medical or health related advice or diagnosis provided by a medical professional with respect to a health problem or disease of a patient Such diagnosis is to be made by the medical professional based solely on the medical professional s examination of the patient Brymill Cryogenic Systems does not make and specifically negates and disclaims any representations and or warranties whether express or implied oral or written concerning the use quality or condition of such images or pictures or the duplication thereof Brymill Cryogenic Systems assumes no responsibility in the manner in which any and all images or pictures created by the CRY AC TrackerCam are used stored duplicated transmitted or disposed of either by a medical professional or non medical person The user is solely responsible and liable for complying with any and all laws regarding the protection and confidentiality of the images or pictures or any portions thereof taken by the CRY AC TrackerCam about a particular patient 3 2 Handling and Warning Notes The CRY AC TrackerCam contains some components that are very sensitive to vibration or shock namely the Infrared Sensors and the LCD Display Screen resulting from improper handling Brymill Cryogenic Systems have taken every possible precaution to ensure the integrity of these components during manufacturing and delivery It is therefore the respo
8. T POINTS LED to identify location of infrared temperature measurement LED color changes as a function of temperature Temp 30 0 C BLUE Temp 0 Tmin C GREEN Temp Tmin C RED amp Below Beep sound to count and indicate when Tmin is achieved Page 19 of 23 INSTRUCTIONS FOR USE 9 4 OPERATING MODES MODE 1 e Display shows Actual temperature reading during use in the large window e Display also shows the total time that Tmin temperature or below was achieved during the freeze cycle e Sound beeps once Tmin is achieved MODE 2 4 AS MODE 1 except e For future use MODE 3 AS MODE 1 except e No sound 9 5 SOFTWARE Firmware is the software that is running inside the microprocessor on the CRY AC TrackerCam It controls LED s and User Button interface There are no known EMC interference issues 9 6 CAMERA e High Definition 2592H x 1944V macro video camera 9 7 TRANSPORT AND STORAGE e Temperature 40 C to 70 C e Humidity 10 85 e Pressure 70kPa to 106kPa 9 8 NORMAL OPERATING CONDITIONS e Temperature 10 C to 35 C e Humidity 10 75 e Pressure 50kPa to 106kPa Page 20 of 23 INSTRUCTIONS FOR USE Section 10 Chart of Beniqn Lesions Chart of Benign Lesions with Freeze Times and CRY AC TrackerCam Temperatures This information is only for guidelines and does not pre empt clinical judgment Number of Interval Type of Lesion Technique Freeze time Tmin Number Margin trea
9. am to strong shocks The CRY AC TrackerCam has been designed to ensure trouble free operation There are no adjustments to be made and there is no special servicing required During normal use the CRY AC TrackerCam will only require charging the batteries as detailed in section 4 2 7 2 Cleaning Caution Do NOT immerse the CRY AC TrackerCam in any liquid Because the CRY AC TrackerCam does not come into contact with the skin infection risk is classified as LOW If necessary the plastic case of the CRY AC TrackerCam head and the CRY AC Body can be cleaned with a clean damp cloth and soapy water or alcohol wipe The cloth should only be moist and NOT dripping wet to reduce any risk of water entering the device Avoid using abrasive cleansers that could scratch and damage the surface of the CRY AC TrackerCam Also avoid touching or contaminating the optical sensors and light emitting diodes on the front of CRY AC TrackerCam 7 2 1 LCD Liquid Crystal Display Dust dirt smears and smudges can result in poor performance of the touch screen functions and therefore should be kept clean at all times LCD screens or displays are NOT GLASS and should not be cleaned using tap water amp paper towels Tap water often includes chemicals like chloride that will leave a residue on the screen Coarse paper towels or cloths may even scratch and damage the very sensitive LCD LCD Cleaning Cleaning kits containing the proper cleaning solutions a
10. d 100 degrees F Keep CRY AC TrackerCam away from heat humidity or harmful chemicals Avoid direct exposure to sunlight to protect the plastic components 7 5 User Self Test Before using the device turn the TrackerCam Unit on and carry out a simple self test e When the display is turned on the Temperature Reading in the main box will read Room Temperature e Now focus the 2 blue beams together on the back of your hand The temperature reading should be 30 C 3 C Page 17 of 23 INSTRUCTIONS FOR USE Section 8 Troubleshooting Please check our website www brymill com for the most current troubleshooting information The CRY AC TrackerCam does not have any effect on the operation of the CRY AC 8 1 CRY AC TrackerCam Troubleshooting Troubleshooting by an end user is limited to 2 operations A problem with Power or a problem with the Display functioning 8 1 1 Faults associated with Power Problem No or Low Power DE The first screen with the Brymill Logo does not appear when the Brymill Power button is pressed twice e No audible beep Battery is fully discharged e Audible beep is heard Battery is very low on power START Low Battery 1 18 08 PM When switched on Low Battery flashes on and off at the Start Screen Devil Solution Recharge the Battery See section 4 2 1 Charging Problem Charger has been connected but the display now flashes Not Charging Solution Disconnect the plug from the
11. d therefore is part of the Procedure Record 19 C zx hers SD card required for recording Touch START Touch MENU This Menu screen appears Touch CLOCK Page 10 of 23 INSTRUCTIONS FOR USE Set Clock Touch the Up or Down arrows on the left of the screen to adjust the Hour Touch the Up or Down arrows in the Set Date 12 18 09 AM Touch the Up or Down arrows on the left of the screen to adjust the Month The Up or Down arrows in the center center of the screen to adjust the of the screen to adjust the Day The Minutes Touch the AM button to Up or Down arrows on the right of switch to PM the screen to adjust the Year Touch SAVE to save the setting or Touch SAVE to save the setting or touch EXIT to cancel changes touch EXIT to cancel changes 5 2 SETTING THE TIMEOUT The Timeout function is the power saving feature of the CRY AC TrackerCam Unit The Timeout is factory set at 300 seconds which is the maximum time the screen will stay on for if there is no variation to the Actual Temperature If you want to reduce the Timeout period then follow this process 19 C s Set Timeout Current Value 120s New Value 90s SD card required for recording 12 18 09 AM Touch MENU This Menu screen appears Touch the Down arrow on the right of touch TIMEOUT the screen to reduce the Timeout period or touch the Up arrows on the left to increase the Timeout period Touch SAVE to save the setting or touch EXIT to cancel c
12. e of the CRY AC TrackerCam Use without turning the Head section on Option 2 By using the full facilities of the CRY AC TrackerCam and record the full treatment process in High Definition video onto a Mini SD memory card To ensure the best results are obtained when using the full Sensing and Video functions of the CRY AC TrackerCam and to ensure that the Spray is positioned at the correct focal and working distance for the camera ONLY the supplied 1 x 20g Straight Spray Needle is recommended The CRY AC TrackerCam is a device that measures the temperature of the skin when spraying Liquid Nitrogen via the CRY AC delivery system to the selected skin lesion In accordance with these Instructions for Use the operator can set the CRY AC TrackerCam to indicate when a predetermined freeze temperature of between 1 C and 70 C has been achieved at the lesion The CRY AC TrackerCam is a recording device only It does not have the capability to play back a video recording from the Mini SD Card To view a recording on the Mini SD Card it must be removed and connected to a computer To connect view or transfer a recording on the Mini SD Card refer to the Instructions for Use User Manual of the device to be used Page 5 of 23 INSTRUCTIONS FOR USE 4 1 PACKAGE CONTENTS san isk s gt 2GB 1 x CRY AC TrackerCam 1 x Mini SD Memory Card with Adapter 1 x Rechargeable Custom NiMH Battery already inserted 1 x Charger
13. g the internet for Battery Safety and Disposal Batteries may present a risk of fire explosion or chemical burn if mistreated Do not disassemble puncture modify drop throw or cause other unnecessary shocks to batteries e Do not dispose of batteries in a fire or trash incinerator or leave batteries in hot places such as under direct sunlight Do not store batteries near an oven stove or other heat source e Do not connect batteries directly to an electrical source such as a building outlet or automobile power point Do not place batteries into a microwave oven or into any other high pressure container Do not immerse batteries in water or otherwise get them wet e Do not touch leaking batteries directly wear protective material to remove the batteries and dispose of them properly immediately Do not reverse the polarity positive and negative terminals of batteries Do not mix used and new batteries or install used batteries in other equipment e Do not charge non rechargeable batteries or use unspecified charging instructions or equipment for rechargeable batteries Do not continue to charge batteries beyond the specified time Do not give batteries to young children or store batteries where children may access them e Do not put batteries in mouth If swallowed contact physician or local poison control center immediately 7 4 Storage Always store the CRY AC TrackerCam device in a dry place at temperatures between 40 an
14. gs remain in memory until a new recording is started In the event that the lesion just treated requires a second Freeze Thaw Cycle the camera will automatically begin to record when the beams are refocused on the lesion and the temperature reaches 0 C and below as the freeze begins STOP YX PAUSE 6 3 Transferring the Recording to a Computer To transfer recording on the SD Memory Card to a Computer follow these steps Ensure the CRY AC TrackerCam Unit is turned off Eject the Mini SD Card from the side of the CRY AC TrackerCam Head Insert the Mini SD Card into the Adapter Insert the Adapter into the appropriate card slot in the computer Open Computer and in Devices with Removable Storage will be a device called CD MMC Open the CD MMC and there will be the video clips currently stored on the Mini SD Memory Card Transfer Copy the files to your chosen file location patient record If the Mini SD Memory Card is to be used again for new recordings delete the existing files Eject the Adapter from the computer Page 15 of 23 INSTRUCTIONS FOR USE Section 7 Routine Maintenance Caution Before carrying out of the procedures detailed in this section ALWAYS e Ensure the CRY AC is empty of Liquid Nitrogen e Ensure the Battery Charger or USB Cable is not connected to the CRY AC TrackerCam e Ensure the CRY AC TrackerCam is turned OFF T 1 Care and Maintenance Caution Do not drop or subject the CRY AC TrackerC
15. hanges Page 11 of 23 INSTRUCTIONS FOR USE 5 3 Understanding the Display Functions of the Main Screen Mode 1 1926 TMin 10 C Below Tmin Elapsed 00 00 00 00 SD card required for recording REC 12 18 09 AM Actual Temperature reading The Infrared Sensors are constantly recording the temperature Below Tmin This will display how long temperatures below Tmin were achieved SD Card required This appears if the Mini SD Card has not been inserted into the Card Slot REC Record Button 12 14 40 AM The actual time of day Tmin 10 Displays the Tmin setting Mode 1 Displays the current Mode setting Elapsed Will display the actual time elapsed between record start and Stop Light This button turns the LED Lights on and off 0 MENU This button takes you to the main Set Up Screen 1 Battery Indicating the battery level md S po m Gl m eS o The top of the display is BLUE Your CRY AC TrackerCam Unit is now ready to use Page 12 of 23 INSTRUCTIONS FOR USE 5 4 TO BEGIN USE Caution Removing or Inserting the Mini SD Memory Card with the power on may result in the loss or damage of any data stored on the Card Caution A Do not look directly at the LED lights If treating facial lesions the Patient must close their eyes and wear suitable non absorbable eye protection 1 Turn the CRY AC TrackerCam on by pressing the Power Button twice 2 Ensure you ha
16. he complete CRY AC TrackerCam must be returned for repair 8 3 CRY AC Troubleshooting For troubleshooting the CRY AC please refer to Section 9 of the CRY AC Instructions For Use booklet However since the Main Valve and Trigger Assembly are now incorporated within the CRY AC TrackerCam housing if any problems exist relating to a sticking Valve or Trigger then the complete CRY AC TrackerCam must be returned for repair The other problems details in Section 9 of the CRY AC Instructions For Use booklet relating to intermittent spray or the bottle frosting still apply Section 9 Technical Specification 9 1 PERFORMANCE REQUIREMENTS e Measurement accuracy better then 5 C e Minimum temperature reading 70 C e Sampling rate greater than 2 Hz e Sample area at focus less than 2 mm 9 2 POWER e 3 6v 2 00mAh Re chargeable NiMH battery and 5v 2 1A Charger When device is not used for 5 minutes the device goes into Sleep Mode To exit sleep mode simply press Power button If device remains in Sleep Mode for 15min the device turns off completely To turn the CRY AC TrackerCam off at any time press and hold Power Button for a minimum of 5 seconds One long and one short beep will be heard 9 3 USER INTERFACE e LCD screen to display ACTUAL TEMPERATURE Tmin and TIME AT Tmin POWER MODE buttons to turn ON OFF and select operating MODE 2 SELECT BUTTONS Function determined by mode and state Used to scroll through measurements and set SE
17. nd cloths are available from most retailers of TV s and Computer products Use a Microfiber Cloth to remove any obvious dust and gently brush off dirt particles Never spray cleaning solutions directly onto the screen spray it into your cleaning cloth DO NOT press hard onto the cloth when cleaning let the cleaning solution do its job Don t leave any liquid on the screen remove all the excess moisture as it may damage the screen Let the LCD Screen dry thoroughly before you switch it back on For hard to remove stains or ink marks you may have to repeat this procedure several times Don t apply hard pressure Page 16 of 23 INSTRUCTIONS FOR USE 7 3 BATTERIES 7 3 1 Battery Replacement Caution Ensure the CRY AC flask is empty of Liquid Nitrogen before carrying out this process To access the battery compartment you need to remove the CRY AC TrackerCam Display Panel by following the Battery Installation Instructions in Section 4 2 1 7 3 2 Battery Safety and Disposal Instructions Please follow the instructions below for safe handling and proper disposal of the battery This symbol on the battery indicates that this product shall not be treated as household waste The rechargeable NiMh battery from the CRY AC TrackerCam can be recycled or disposed of as follows e Dispose or recycle the battery according to the local laws and regulations of your country and region These regulations are available by simply surfin
18. nsibility of the End user that every effort is made to protect the CRY AC TrackerCam against vibration or shock that could ultimately result in a component failure Ensure the CRY AC TrackerCam is kept in an upright position at all times when Liquid Nitrogen has been decanted into the Flask and the cover has been replaced CAUTION A No modification of this equipment is allowed Any tampering with this device will void the warranty This unit must be use below 2000 meters 3 3 Warranty The CRY AC TrackerCam section of the CRY AC TrackerCam is covered by a 1 year limited warranty against manufacturing defects in materials and workmanship The CRY AC section of the CRY AC TrackerCam is covered by the same 3 year warranty defined in the CRY AC Instructions For Use booklet supplied with each unit The Charger comes with a 1 year warranty The Battery comes with a 3 month warranty These warranties do not cover damage resulting from abuse neglect improper handling or improper use Page 4 of 23 INSTRUCTIONS FOR USE 4 CRY AC TrackerCam Introduction Reset center hole Touch Screen amp Display DC Charging Port On Off Power and Sleep Button Retaining Screw Microphone LED Lights Mini SD Card Slot Camera Infrared Sensor Mini USB Port Infrared Beams Left Side The CRY AC TrackerCam is a device that can be used in 1 of 2 ways Option 1 By using just the CRY AC spray part without the us
19. of 23 INSTRUCTIONS FOR USE Section 2 READ BEFORE USE il CAUTION A BEFORE USING THE CRY AC TrackerCam ENSURE YOU HAVE READ THE FOLLOWING INSTRUCTIONS FOR USE CRY AC TrackerCam INSTRUCTIONS FOR USE CRY AC Keep them in a safe place for future reference This Device is in compliance with 60601 1 2 Instruction for Use in the following languages English German French ltalian Dutch Swedish Danish Portuguese Spanish Japanese Can be found and downloaded from the web site at http www brymill com Page 3 of 23 INSTRUCTIONS FOR USE Section 3 Indication for Use The CRY AC TrackerCam is a device that measures the temperature of the skin when spraying liquid nitrogen via a CRY AC 3 delivery system to the selected skin lesion using the latest infrared censoring technology It is the physician s responsibility to decide which skin lesions are to be treated using Liquid Nitrogen since some respond better than others Published literature and textbooks are available that identify those skin lesions best suited to treatment using Liquid Nitrogen 3 1 Use Of Content The CRY AC TrackerCam is intended for the use by a medical professional trained in the use of cryogenic products for the care of a patient it is not intended to be used by a non medical professional The medical professional is responsible for reviewing and interpreting the images or pictures or any portions thereof created by
20. tery simply disconnect the battery plug and remove the battery Insert a new battery and reconnect the battery plug Page 7 of 23 5 Now carelully place the upper assembly back into the lower assembly Caution A Be aware not to pinch the ribbon cable when closing Charging The Battery Plug the charger into a 110V 220V electrical power outlet Plug the supplied charger connector into the DC Charging Port See picture opposite for Port location The CRY AC TrackerCam screen will begin to flash indicating the unit is charging To ensure proper operation you must leave the unit charging when not in use including in between patience The battery indicator has 5 segments When all 5 are showing then the battery is deemed to be fully charged When only 1 segment is showing then the battery requires charging A fully charged custom NiMH battery provides about 1 hour of continuous operation with the lights on Optionally you may use a USB cable to charge the battery via the mini USB port to your computer Access to the battery is now only necessary when replacement is required CAUTION A When charging with a USB cable the CRY AC TrackerCam must be connected only to the USB port of a computer that complies with the IEC EN 60950 standard to ensure continued compliance of the product with the European Medical Device Directive Refer to the operator s manual provided with your computer to ensure that the computer complies
21. tment weeks seconds Setting C of FTC mm sessions Actinic keratosis S 5 Common warts S 10 Cutaneous horn OS 10 15 10 Dermatofibroma OS 20 30 15 Hypertrophic scar Ingrown toenail Keloid Myxoid cyst O e Pyogenic granuloma ae 1 LOT LOS a _ 134 eT LI l j LI s Skin tags FTC freeze thaw cycle OS Open Spray spot freeze technique Period of Time to maintain the freeze ball or halo formation at Tmin not the total spray time Skin Types to Ill T Interval between repeat treatment sessions Target is inflamed granulation tissue and treatment is helpful in selected cases References Cryosurgery for Common Skin Conditions M D Andrews MD Am Fam Physician 2004 May 15 69 10 2365 2372 Liquid Nitrogen Temperature Control in the Treatment of Actinic Keratosis L H Goldberg amp Col Dermatology Surgery December 2010 Vol 26 Number 12 Experience in the use of the Brymill CRY AC Tracker for the Treatment of Benign Skin Lesions with Cryosurgery Eduardo De Carli MD Argentina Society of Dermatology Page 21 of 23 Section 11 Explanation of Utilized Symbols The following symbols are used on the device or on the packaging or Instructions for Use FE CONSULT INSTRUCTIONS FOR USE CAUTION The CE Mark and 0120 reference indicates that the product complies with the European Medical device Directive 0120 93 42 EEC Annex II POWER BUTTON
22. ve removed the shipping spray tip plug and attached a 1 x 20g Straight Spray Needle to the end of the Delivery Tube of the CRY AC 3 Print the patients name and Medical Record Number onto a piece of paper 4 Using the Table in Section 10 Set Tmin Set Tmin Current Value 22 C New Value 30 C Touch MENU This Menu screen appears Touch the Down arrow on the right of Touch TMIN the screen to decrease the Tmin or Touch the Up arrows on the left to increase the Tmin Touch SAVE to save the setting or Touch EXIT to cancel changes 12 18 09 AM 5 Set the required MODE MODE1 Buzzer beeps once a second as long as Tmin is achieved MODE 2 4 For future use MODES No sound Set Mode Current Value 3 New Value 1 Touch MENU This Menu screen appears Touch either Up or Down arrows to Touch MODE scroll to the required Mode Touch SAVE to save the setting or Touch EXIT to cancel changes Page 13 of 23 INSTRUCTIONS FOR USE Section 6 Recording Process 6 1 Additional Lighting Additional Lighting is available by touching the light bulb icon This can be turned ON or OFF at any time LITER 12 18 09 AM BENE 12 18 09 AM Touch the Light button if you require Lights are now ON additional lighting When ready Touch REC 6 2 Recording Processes Point the camera at the paper with the Patients name and pertinent information Press REC and the Camera will commence the recording process 12
23. with the above standard When the battery charge is depleted the unit will automatically shut off and will need to be recharged Note Safety features within the software have been incorporated to prevent the CRY AC TrackerCam being used with the Charger or Mini USB leads connected After approximately 500 charges the battery s capacity will diminish and the battery may need to be replaced To replace the battery go to Section 6 3 Access to the battery is now only necessary when replacement is required Page 8 of 23 4 2 2 MINI SD MEMORY CARD Your CRY AC TrackerCam is also supplied with a 2gb capacity Mini SD Memory Card and a Card Adapter The Mini SD Memory Card is inserted into the Card slot on the left side of the CRY AC TrackerCam Head The Mini SD Memory Card can only be inserted one way That is with the connectors facing you Slide the Mini SD Memory Card into the slot and press firmly until you hear the click This indicates the Card is locked in place To eject the Mini SD Memory Card wait 10 seconds after video recording has stopped Failure to wait may result In the loss or corruption of files Press it in until you hear the click and then release it The Card will eject partly out Ensure the Card adapter is kept in a safe place as this may be required to enable the saved video clips to be transferred to a computer 4 2 3 RESET BUTTON The CRY AC TrackerCam has been designed with a Reset Button This