Home
GT15 Serial communication unit User`s Manual
Contents
1. Dimensions of X when the serial communication unit is mounted to the GOT 15 19 5 0 77 21 0 83 12 1 18 0 71 18 0 71 10 4 21 0 83 21 0 83 8 4 23 0 92 23 0 92 5 7 23 0 92 23 0 92 Unit mm inch 3 Back view For GT15 RS4 9S TE only Expanded figure of part 6 00000000 T NO E O m 6 No Name Description 1 Mounting screw Mounting screws fixed with a front extension 9 unit or GOT 2 Interface Extension connector installed to a front connector extension unit or the GOT 3 Extension Extension connector to which a back extension connector unit is installed Serial Connector for connecting a serial 4 communication communication cable For GT15 RS4 TE the connector terminal block socket is connected 5 Terminal block Socket for connecting a serial communication socket cable to the serial communication connector No Name Description Switch to set terminating resistor When using DIP switch the built in terminating resistor 100Q turn 6 For GT15 RS4 both No 1 and No 2 switches on When using 9S TE only the external terminating resistor turn both No 1 and No 2 switches off 7 Rating plate 4 INSTALLATION PROCEDURE The installation procedure for the serial communication unit is explained using the GT1575 4 1 Serial communication unit
2. lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction INSTALLATION PRECAUTIONS CAUTION Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage DESIGN PRECAUTIONS lt gt DANGER Do not bunch the control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAU
3. TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan June 2011
4. depending on the controller connected For details refer to GOT1000 Series Connection Manual for GT Works3 corresponding to the controller used Select a serial communication unit according to the connection type When using the serial communication make the communication settings to perform communication between the GOT and PLC Since the GT15 RS4 TE cannot control the signals RS CS the unit cannot be connected to the PLC For the details of the connection type refer to GOT1000 Series Connection Manual for GT Works3 corresponding to the controller used When using serial communication unit use a standard monitor OS and communication driver of GT Designer2 Version2 15R or later With a standard monitor OS and communication driver of an older version the GOT has cannot recognize the unit to perform monitoring 2 2 Specifications of terminal block socket For GT15 RS4 TE only Item Specifications Screw tightening torque 0 20 to 0 25 Nem DIN 5265 ISO 2380 2 compliant product Recommended driver DIN 5264 Product with the tip chrome plated based on the ISO 2380 1 standard 0 08 to 1 5 mm3 Applicable wire size 3 PART NAMES AND EXTERNAL DIMENSIONS 1 GT15 RS2 9P PS4 9S GOT main 63 2 48 aay om A Foe 2 GT15 RS4 TE 63 2 48 3 GOT main 0 72 unit al POLL
5. installation The following figures show an example of the GT15 RS2 9P RS4 9S installation The installation of the GT15 RS4 TE follows the same procedure 1 Power off the GOT 2 Remove one extension unit cover of the GOT 4 Fasten the serial communication unit by tightening its mounting screws 2 places with tightening torque 0 36 to 0 48 Nem 5 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 2 places Keep the connector cover fixed Keep the sticker stuck as it is Accessory stickers cover Sticker If you remove the serial communication unit detach it from specified direction shown PULL so as not to break a connector 4 2 Terminal block socket installation For GT15 RS4 TE only 1 Insert the terminal block socket in the serial communication unit 2 Fasten the terminal block by tightening the terminal block fixing screws 2 places with the tightening torque of 0 20 to 0 25 Nem Expanded figure of part A A terminal block fixing screw Point When attaching or removing a communication cable to from the terminal block socket detach the terminal block socket from the connector When extension units are installed in multiple layers
6. MITSUBISHI GT15 Serial communication unit User s Manual GT15 RS2 9P GT15 RS4 9S GT15 RS4 TE Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 RS2 4 U MODEL CODE 1D7M40 IB NA 0800325 I 1106 MEE GRAPHIC OPERATION TERMINAL GOTioo0 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause amp DANGER hazardous conditions resulting in death or severe injury I I I Indicates that incorrect handling may cause CAUTION hazardous conditions resulting in medium or I 4 slight personal injury or physical damage er v Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user INSTALLATION PRECAUTIONS
7. Mounting screw set 2 screws 2 stickers GT15 RS4 TE Terminal block socket Plate type solderless terminal For con necting braided shield cable For handling of the ferrite core refer to For users intending to connect the GOT directly to a PLC using the RS 422 cable GT01 C30R4 25P provided with the product 1 OVERVIEW This User s Manual describes the GT15 Serial communication unit hereinafter referred to as the serial communication unit The serial communication unit is used when performing the serial communication between GOT and a FA device For attachable GOTs refer to the User s Manual for the GOT used 2 SPECIFICATIONS 2 1 Performance Specifications The performance specifications of the serial communication unit are indicated below The general specifications of the serial communication unit are the same as those of the GOT Refer to the User s Manual for the GOT used for the general specifications of the GOT tans Specification GT15 RS2 9P GT15 RS4 9S GT15 RS4 TE Transmission method RS 232 RS 422 485 RS 422 485 compliant compliant compliant D sub 9 pin D sub 9 pin z Interface Male Female Terminal block DDK make DDK make Connector 17LE 23090 17LE 13090 27 D3CC 27 D3AC 2005 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and L
8. TION Use crimp contact pressure displacement or soldering to wire the connectors for external connections properly using the manufacturer specified tools If the connection is incomplete it may cause the module to short circuit catch fire or malfunction Connect the connectors to the unit securely Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault STARTUP AND MAINTENANCE PRECAUTIONS lt gt DANGER Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction CAUTION Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or
9. ando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU
10. ial purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Is
11. malfunctions of the unit DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Manuals The following shows manuals relevant to this product Detailed Manuals Manual number Model code SH 080928ENG Manual name GT16 User s Manual Hardware Sold separately 1D7MD3 GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Series Connection Manual Mitsubishi Products for GT Works3 SE S Sold separately GOT1000 Series Connection Manual F Non Mitsubishi Products 1 for GT Works3 MES Sold separately GOT1000 Series Connection Manual ki Non Mitsubishi Products 2 for GT Works3 SMe S Sold separately GOT1000 Series Connection Manual Ly Microcomputer MODBUS Products MeS Peripherals for GT Works3 Sold separately Relevant Manuals For relevant manuals refer to the PDF manuals stored in the CD ROM for the drawing software used Product Quantity RS 422 485 serial communication unit
12. ow Voltage Directives when incorporating the Mitsubishi GOT EMC and Low Voltage Directives compliant into other machinery or equipment refer to EMC AND LOW VOLTAGE DIRECTIVES of the General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT Compliance with the Radio Waves Act South Korea This product complies with the Radio Waves Act South Korea Note the following when using the product in South Korea OIE 898 A8 UHSE BOW Le NBME 0 SS SALI Het HAAA ASA ANSoe AS SAC g Buc The product is for business use Class A and meets the electromagnetic compatibility requirements The seller and the user must note the above point and use the product in a place except for home Packing List The following items are included Product Quantity RS 232 serial communication unit GT15 RS2 9P Mounting screw set 2 screws 2 stickers RS 422 485 serial communication unit GT15 RS4 9S Mounting screw set 2 screws 2 stickers Ferrite Core Transmission speed 115200 57600 38400 19200 9600 4800bps Synchronous type Non Synchronous type Asynchronous type Error detection Parity check sum check method Maximum F transmission distance iam om 1200 Imternal current 0 294 0 33A 0 3A consumption 5VDC Weight 0 09kg 0 201 The maximum transmission distance differs
13. the units do not have to be removed from the GOT main unit 4 3 Connecting the braided shield cable For GT15 RS4 TE only When connecting the braided shield cable inside the RS 422 485 cable use the plate type solderless terminal included with the product Before connecting each cable inside the RS 422 485 cable to the terminal block remove the cable sheath by 7mm 0 28 inches Plate type solderless terminal Braided shield cable Point Tighten the terminal block wiring screws with the tightening torque of 0 5 to 0 6 Nem When using the plate type solderless terminal be sure to insert the terminal in the horizontal direction toward the terminal block The solderless terminal may come off when it is inserted in the vertical direction Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for spec