Home

VCL-SafeComm 8 E1 Links (24 E1 Ports)

image

Contents

1. 1 Links 24E1 Ports 1 1 Automatic 2DC048 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 48V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set Technical specifications are subject to changes without notice Windows is the registered Trademark of Microsoft Corporation USA Revision 09 Aug 23 2012 Headquarters Phoenix Arizona Regional Office Miami Florida Orion Telecom Networks Inc Orion Telecom Networks Inc 20100 N 51stAve Suite B240 4000 Ponce de Leon Blvd Suite 470 Glendale AZ 85308 Coral Gables FL33146 U S A Phone 1 480 816 8672 Phone 1 305 777 0419 Fax 1 480 816 0115 Fax 1 305 777 0201 E mail sales oriontelecom com E mail sales oriontelecom com Website http www oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2007 12 12
2. E1 Ports 1 1 Automatic Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 1 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set Orion Telecom Networks Inc 2007 12 11 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Ordering Information S No PartNo Product Description 6 VCL 1430 APS 08 24E1 EXT VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic 2AC220 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 7 VCL 1430 APS 08 24E1 EXT VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic 2DC024 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 24V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 8 VCL 1430 APS 08 24E 1 EXT VCL SafeComm 8E
3. Efficiency at full load gt 86 DC Power Supply Specifications Input DC voltage Dual Input 48V DC nominal Range of input voltage 18V to 72V DC System voltage 3 3V Input voltage reversal protection Provided in the Card Short circuit protection Provided Power Consumption lt 10W Operations and Maintenance OAM Interfaces e RS232 serial interface for local terminal access e USB serial interfaces for local terminal access e 10 100BaseT Ethernet Interface for remote access over an IP network Command Language o Command Line Interface English text commands Orion Telecom Networks Inc 2007 12 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Compliance Regulatory e EMCFCC Part 15 Class 2 e Safety UL 1459 Issue 2 e Operation ETS 300 019 Class 3 2 e Storage ETS 300 019 Class 1 2 e Transportation ETS 300 019 Class 2 3 Management and Monitoring e RS232 serial USB serial interfaces for local terminal access e 10 100BaseT Ethernet Interface for remote access over an IP network e Encrypted Password Protection e Telnet Remote access over IP links e SSH Secured remote access using Secure Shell Protocol over IP links e SNMP Traps and NMS for real time remote monitoring and management over an IP network e Automatic Link Test feature link testing at user programmable periodical intervals e Visual I O status LED Display NMS wit
4. IN standard 19 Inch rack This product allows the user to design 1 1 protected redundant E1 routes on similar fiber fiber or complementing fiber radio transmission mediums The criterion for switching between the primary main and the secondary protected standby routes is user programmable Criterion for switching between the primary main and the secondary protected standby routes may be Loss Of Signal on E1 links or AIS All Ones AIS alarm condition The criterion for switching time and recovery time between the primary main and the secondary protected standby routes is user programmable Data transported on the E1 Links is transparent and protocol independent Applications Providing 1 1 alternate paths between any two E1 Transmission mediums active standby E g e Fiber Fiber e Radio Fiber e Radio HDSL e Fiber HDSLetc Example The user may deploy the VCL SafeComm 8 E1 1 1 Automatic Protection Switching Equipment to provide an alternate communication route between an optical fiber link and a radio link between any two points In the event of the failure of the primary optical fiber link the E1 is automatically switched to the alternate route over the E1 radio thus ensuring maximum uptime on all such 1 1 protected E1 Links Once the primary optical fiber E1 Link on the optical fiber is restored the VCL SafeComm 8 E1 1 1 Automatic Protection Switching Equipment automatically restores the communicat
5. IS or a LOS LOSS OF SIGNAL alarm on the MAIN E1 link route Similarly in the automatic mode the switch shall automatically switch back and re route the E1 circuits from the STANDBY route to the MAIN route upon the restoration of the service on the MAIN E1 link route All switching parameters and link restoration parameters are user programmable EXTERNAL TRIGGER SWITCHING MODE Sometimes the user wants to switch the E1 circuits between the MAIN route and the STANDBY route when some external event occurs In the EXTERNAL TRIGGER MODE the user can switch between the MAIN E1 route and the STANDBY E1 route when an external trigger such as an closed opened physical contact is applied to the switch This unique feature is used by certain radios equipment suppliers where they apply an external trigger to switch and re route the E1 circuits between their main E1 radios and standby E1 radios MANUAL SWITCHING MODE In Manual Switching Mode the user shall use manual Telnet commands to switch the E1 circuits between the MAIN route and the STANDBY route manually using Telnet commands In this mode the AUTOMATIC MODE and the EXTERNAL TRIGGER MODE are both disabled and the manual commands over ride all other modes Orion Telecom Networks Inc 2007 12 7 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Front View AC Version VCL SafeComm 8 E1 Links 24 E1 Ports EQUIPMENT MAIN LINE STANDBY LINE Automatic Protection Switchi
6. JRION NETWORKS ORION TELECOM NETWORKS INC VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 Automatic Protection Switch Product Brochure amp Data Sheet Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 1 480 816 0115 E mail sales oriontelecom com Website http www oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2007 12 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Product Description The VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 Automatic Protection Switching Equipment may be used to protect upto 8 E1 Links 24 E1 Ports point to point links and provide an alternate communication route to each E1 li between any two E1 points In the event of the failure of VCL SafeComm 8 E1 Links 24 E1 Ports primary Main E1 communication route the 141 A ic Protection Switchi APS VCL SafeComm 8 E1 Links 1 1 Automatic Protection utomatic Protection Switching APS Switching Equipment automatically switches the E1 traffic to a secondary standby E 1 route The VCL SafeComm 8 E1 1 1 Automatic Protection Switching equipment is available in a 2U high chassis which may be mounted in any D
7. ary E1 1 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set VCL 1430 APS 8 24E1 2AC220 VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set VCL 1431 APS 8 24E1 2DC024 VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 24V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set VCL 1431 APS 8 24E1 2DC048 VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Secondary E1 2 x 48V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set VCL 1430 APS 08 24E 1 EXT 1AC220 VCL SafeComm 8E1 Links 24
8. ed protection E1 facilities while continuously maintaining the performance of both links to determine which link shall be utilized Figure application 4 Working Link E1 Link Protection Link Duplicate Mobile Switching Office H Remote Cell Site Orion Telecom Networks Inc 2007 12 4 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Features amp Highlights High density protection switching equipment upto 08 E1 Links i e 24 E1 Ports To provide an independent point to point protected E1 Link between two E1 USER PORTS on similar example fiber fiber or dissimilar fiber radio mediums To provide 1 1 E1 redundancy Remote system configuration and management interface through CLI text based commands using Telnet and GUI Graphical User Interface Provide 1 1 Protection Routing Path between BSC and BTS These ensure that mission critical voice data control and management traffic are properly supported and maintained even during E1 backhaul facility outages When the primary working link fails the E1 traffic is automatically switched to the standby secondary link to ensure maximum uptime Through the comprehensive remote configuration and alarm management capabilities of the VCL SafeComm 08 E1 1 1 Automatic Protection Switching Equipment the product may be used to improve network reliability and control Traffic Protection e Alternate Facility Advantages e Service Dif
9. ferentiation Agreements e Increased Network Reliability Resilience e Media and Path Diversity e Remote Management e Alarm logging and monitoring Benefits e Competitive e Service Level e Back haul Network e Technology Migration e User Programmable 1 1 Protection Parameters gt Loss Of Signal LOS gt Alarm Indication Signal AIS gt External open close dry contact signal User programmable criterion for switching between Active and Standby E1 Links at the customers premises Loss of E1 Signal LOS The Loss of Signal condition in a E1 may occur due to e The failure of the E1 Port of the customer premises equipment e Or due to loss of power to the customer premises equipment e Or due to the disconnection of the E1 Cable between the protection Switch and the E1 Port of the customer premises equipment Alarm Indication Signal AIS This Alarm indicates that a E1 link error has occured External Dry Contacts Signal This indicates the External Dry Contacts open close state Orion Telecom Networks Inc 2007 12 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Security and Password Features System Access Control and Management Options e Telnet e SSH e CLI Control Interface HyperTerminal or VT 100 e SNMP V2 Traps MIB File provided e Windows based GUI Graphical User Interface for easy configuration management and access Ability to monitor multiple units f
10. h Telnet XPort Specification Network interface RJ 45 Ethernet 10BaseT or 100BaseT TX auto sensing Compatibility Ethernet Version 2 0 IEEE802 3 Protocols supported ARP UDP IP TCP IP Telnet ICMP SNMP SSH LEDs 10Base T and 100Base TX Activity Full half duplex Management SNMP Serial login Telnet login SSH EMI Compliance Radiated and conducted emissions complies with Class B limits of EN55022 1998 Direct and Indirect ESD complies with EN55024 1998 RF Electromagnetic Field Immunity complies with EN55024 1998 Electrical Fast Transient Burst Immunity complies with EN55024 1998 Power Frequency Magnetic Field Immunity complies with EN55024 1998 RF Common Mode Conducted Susceptibility complies with EN55024 1998 Mechanical Specifications Rack mounting Standard 19 Inch DIN Rack Height 44 00 mm Depth 260 00 mm Width 477 00 mm Weight 4 3 Kg Temperature Operating 0 C to 50 C Humidity 5 to 95 Non Condensing Orion Telecom Networks Inc 2007 12 10 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Ordering Information S No Part No Product Description 1 VCL 1430 APS 8 24E1 1AC220 VCL SafeComm 8E1 Links 24E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 24 x E1 1200 RJ45F 8 for Main E1 8 for Primary E1 8 for Second
11. ion to the primary optical fiber E1 Link The switching time and restoration criterion is user programmable Orion Telecom Networks Inc 2007 12 2 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Application Diagram Figure application 1 Microwave Microwave System System E1 E1 SafeComm 8 E1 Links 24 E1 Ports SafeComm 8 E1 Links 24 E1 Ports Upto 8 E1s Upto 8 E1s E1 Point to Point Application May be used in a point to point configuration to provide 1 1 Protected Alternate Routing Path between any two points using diverse or similar E1 transmission mediums Figure application 2 TYPICAL STAR CONFIGURATION A B C a BTS BTS NV A 1 1 Redundant Link 7 Ae N I N MW MW MW 24 LINK LINK LINK Orion Telecom Networks Inc 2007 12 3 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Figure application 3 Central Site 8E1s a Ir Ring 4E1s Protection Eo it SEVAPS Opt 4 E1s 8E1s Site B Ha 4 E1s 8 E1 APS Application to provide resilient protected E1 rings over PDH networks The VCL SafeComm may also be used in 1 1 redundant protected E1 rings on PDH networks using diverse or similar E1 transmission mediums How It Works VCL SafeComm With Path Protection Switching During normal operation VCL SafeComm sends duplicate traffic across both the working and dedicat
12. ng APS e 2 PWR PWR 7 5V DC OOOO ara ETH OAM COM PORT OAM RESET DC Version VCL SafeComm 8 E1 Links 24 E1 Ports EQUIPMENT MAINLINE STANDBY LINE Automatic Protection Switching APS E L e o asvoc PWR _gavpc PWR INPUT 1 INPUT 2 OAM COM PORT ET Q Orion Telecom Networks Inc 2007 12 8 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Technical Specifications Network Interface Number of Interfaces 8 for Main E1 Links 8 for Primary E1 Links 8 for Secondary E1 Links Line Rate E1 2 048 Mbps Line Code HDB3 Frame Structure G 704 Jitter Tolerance As per ITU T G 823 Output Jitter lt 0 05 Ul in the frequency range of 20 Hz to 100 KHz Nominal Line Impedance 120 Ohms Balanced RJ 45 Pulse Mask As per ITU CCITT Rec G 703 Loss and recovery of frame alignment As per clause 3 of ITU CCITT G 732 Loss and recovery of multiframe alignment As per clause 5 2 of ITU CCITT G 732 AC Power Supply Specifications Output voltage of AC Adapter 100 240 Volt AC Range of input AC voltage 100 V to 240 VAC 50Hz 60Hz System Input voltage 7 5 V DC to 9 0 V DC DC input polarity protection Maximum full load output current 2 5 A at 7 5 V DC 9 0 VDC Input voltage reversal protection Provided in the Card
13. rom a single NMS OAM Operation and Management Ports RS232 Serial Port e USB COM Port e 10 100BaseT Ethernet for remote access Security and Protection e SecuredAccess via SSH V2 e Password Protection Password Protection in compliance with the mandatory clauses of the GR 815 CORE 2 specifications for secured access control Logging Maintains a log of all successful and un successful attempts e Logged information includes the ID and the IP address of the accessing entities e Alerts the administrator if the un successful logging attempts exceed three e Security Audit All access logs for up to 30 days are maintained for security audit purposes e Security log entry of any request or activity including that user ID including IP address if applicable to establish user accountability Report Generation Audit Trail e Security Administration Orion Telecom Networks Inc 2007 12 6 VCL SafeComm 8 E1 Links 24 E1 Ports 1 1 APS Mode of Operation There are three modes in which the VCL SafeComm E1 1 1 Automatic Protection Switch can be configured to operate in 1 AUTOMATIC SWITCHING MODE 2 EXTERNAL TRIGGER SWITCHING MODE 3 MANUAL SWITCHING MODE AUTOMATIC SWITCHING MODE The VCL SafeComm can be configured to operate in an AUTOMATIC SWITCHING MODE In the automatic mode the switch shall automatically switch and re route the E1 circuits from the MAIN route to the STANDBY route if there is an A

Download Pdf Manuals

image

Related Search

Related Contents

инструкцию    HEA VY DUTY CLUTCH CA T ALOG  デジタル放送およびアンテナシステム  Flo-Center™ Software  Wireless Pulse Oximeter    Nokia Bluetooth Headset BH-108  User`s Manual  USER MANUAL - Direct Imports  

Copyright © All rights reserved.
Failed to retrieve file