Home
USER`S MANUAL - Oak Tree Health
Contents
1. 23 Understanding Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions normal high and low The result you get should be inside the acceptable range for the appropriate control solution level Make sure you compare the result to the correct level of control When the control result is inside the range on the test strip bottle your test strips and your meter are working properly If your control solution result is not inside the acceptable range printed on your test strip bottle here are some things you can do to solve the problem Note If you don t set CtL mode control solution values will be included in the memory and averages Refer to the section Viewing Deleting Test Results to delete the control solution values before averaging your test results 24 Troubleshooting Checks Action P l was the tesi SEN Repeat the control test with properly stored strips period of time If the cap was not tight or the bottle was left uncapped open a new bottle of test strips Do not reuse the strips from the affected bottle Y Does test strip cap close tightly Or was test strip cap left open If not you can use control solution to verify the PORE gt Is the meter functioning well meter s functions Chapter 2 Replace with new control solution to check the Is the control solution expired or contaminated performance of SMBG system
2. EASYMAX SELF MONITORING BLOOD GLUCOSE SYSTEM USER S MANUAL EASYMax wi Self Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter Dear EasyMax V SMBG System Owner Thank you for using the EasyMax y Self Monitoring Blood Glucose SMBG System We designed this system to be dependable easy to use compact lightweight and portable to help you monitor your blood glucose on a regular basis Please read this manual thoroughly before you begin testing This manual provides you and your diabetes care team with important information and step by step direction to use the EasyMax V Self Monitoring Blood Glucose System Thanks again for choosing the EasyMax V SMBG Intended Use The EasyMax V Self Monitoring Blood Glucose Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood from fingertip palm or forearm Testing is done outside the body In Vitro diagnostic use It is indicated for use at home over the counter OTC by a single patient with diabetes and should not be shared as an aid to monitor the effectiveness of diabetes control The system is not to be used on neonates nor for the diagnosis of or screening for diabetes mellitus Alternate site testing can be only used during steady state blood glucose conditions Important Safety Instructions Lancets and meters are for single use only A n
3. The meter will turn off automatically Or you can press and hold power button to turn your meter off Low battery symbol Note 1 The meter won t delete earlier records after you replace batteries 2 You should reset the time and date again after you replace the batteries See Section Setting the time and date in Chapter 1 3 1 5V AAA x 2 batteries are available at most stores You may take the old batteries with you for replacement 4 Remove batteries when you will not be using the meter for one month or more 40 Cleaning And Disinfecting Your Meter And Lancing Device Cleaning And Disinfection Instruction Please keep the meter and lancing device free of dirt dust bloodstain and water stains EasyMax V blood glucose meter and lancing device should be used only on one patient and not shared Follow these guidelines carefully to clean your meter 41 Cleaning Instruction All blood and other body fluids must be thoroughly cleaned from surfaces and objects before disinfection by the germicidal wipe Open unfold and use first germicidal wipe to remove heavy soil after every use Disinfection Instruction Unfold a clean wipe and thoroughly wet all the surface of the meter including the strip port and other connection port Unfold a clean wipe and thoroughly wet all the surface of the lancing device including cap or AST cap if used Treated area must remain visibly wet for a full 2 minutes Use additional wipe s if ne
4. Were test strips and control solutions stored in Repeat the control test with properly stored strips cool dry places and or control solutions Read Chapter 2 Control Solution Testing and test again Stop using the meter if you continue to Did you follow the testing steps properly obtain inaccurate results Please contact the EasyMax Customer Care Service line at 866 994 3345 for further troubleshooting 25 Chapter 3 Testing Your Blood Glucose Using the Lancing Device The best depth setting is the lowest setting that draws enough blood for a test Try different settings to find the one that s right for you m Please do not share your lancing device with anyone And always use a new sterile lancet Lancets are for one time use only WR Ifthe meter and lancing device are being operated by a second person who is providing testing assistance to the user the meter and lancing device should be disinfected prior to use by the second person For the disinfection instruction please refer to Chapter 5 Maintenance And Troubleshooting Cleaning and disinfecting your meter and supplies Note Used test strips and lancets are considered bio hazardous waste in accordance with U S local regulations and should be handled as if capable of transmitting infection The users may discuss methods for disposing used test strips and lancets with their doctor 26 Inserting a Lancet Into The Lancing Device You must first load the la
5. 8 Press power button to repeat the massage your fingertip transparent window of the test strip test result Or you can also press C until a round drop of blood Do not put blood on top of the strip button or M button to set the volume on your fingertip Be sure to get enough blood on the before repeating the result strip s reaction zone Otherwise an inaccurate reading may result 7 The meter starts to count down from 5 seconds and speaks the result 9 Remove the test strip and the meter turns off automatically 10 Wash hands thoroughly with soap and water after handling the meter lancing device and test strips Note 1 Please make sure to apply blood when the blood drop appears on the display 2 Please check if the result on the display is the same as audible result 30 Alternate Site Testing AST Understanding Alternate Site Testing What is AST What is the advantage of AST Besides the fingertip you can test the palm or You have the option of testing other places on forearm your body besides the fingertip Consult your health care professional before you begin using the palm or forearm for testing Blood glucose test results obtained from your palm or forearm may differ significantly from fingertip samples We strongly recommend that you Do AST ONLY in the following intervals In a pre meal or fasting state more than 2 hours since the last meal Two hours or more after taking insulin Two hours or more
6. Mon Fri 8 00AM 6 00PM During non service hours please contact your healthcare provider Note Although the EasyMax V SMBG System is easy to use you may need to consult with your healthcare professional this may be your doctor pharmacist or diabetes nurse educator for instructions on how to use the system Only the correct use of the system will ensure accurate results Important Information About Your New Meter EasyMax V blood glucose meter is designed and approved for testing fresh capillary whole blood samples from your fingertip palm and forearm The meter is for in vitro use ONLY for testing outside the body It should not be used to diagnose diabetes EasyMax V blood glucose meter can only be used with EasyMax Blood Glucose Test Strips Other test strips will give inaccurate results Testing is not valid for neonatal blood specimens Do not disassemble the meter as this may cause damage to the components resulting in incorrect readings Disassembling the meter will also void the warranty Always keep the meter clean and store it in a safe place Protect the meter from direct sunlight to ensure a longer lifespan You should not store the meter and test strips in a car a bathroom or a refrigerator Keep the meter test strips and lancing device away from children and pets You should not test critically ill patients with home use blood glucose meters Incorrect results may occur when performing the test If your glucos
7. after exercise Do NOT use AST if you think your blood glucose is low you are unaware of hypoglycemia your AST results do not match the way you feel you are testing for hyperglycemia your routine glucose results are often fluctuating 31 Fingertip test only If sick If blood glucose is low After exercising Two hours or less after eating When basal insulin is most active After injecting rapid acting insulin two hours or less What NOT to do El If the blood glucose test result from the alternate site test does not match how you feel do a fingertip test to confirm the result again E Do NOT change your treatment just because of an alternate site result do a fingertip test to confirm the result a If you do not often notice when your blood glucose is low do a fingertip test Caution a Talk with your healthcare professional before you test palm or forearm al Do NOT ignore symptoms of high or low blood glucose a Fingertip samples are able to show the rapid change of glucose faster than forearm samples a Measurements from alternate site testing should never be used to calibrate a continuous glucose monitor CGM or entered into insulin dose calculators for insulin dosing recommendations 32 Running A Blood Glucose Test With Blood From Your Forearm Please use the clear cap with the lancing device for AST testing 1 This graphic shows where 2 Massage the puncture area of 5 Press the trigger button t
8. Glucose Test With Blood From Your Palm occcccocccnccncccnnccnocnnnconononnnnncncnnnnnnnnnonnannnnnos 34 DIS Carding SEG Lance ai dl te lala O 35 Selen WEE 36 Uhtustial estres ia ld ta dee a ed ali OO Comparing Your Meter Result Tolabesults 37 Chapter 4 Meter Memory Setup A RHE Ee 38 Memory Stoning ET EE 38 Viewing amp Deleting Test Results E 39 Chapter 5 Maintenance And Troubleshooting sa nnnnennneesnnnneenrnnsrnrrnsrrrnrsrrrnsnrrrnsrrrrnsrrrresrrrresrrreesrrrenne 40 Jee eg En 40 Cleaning And Disinfecting Your Meter And Lancing Devce Al Cleaning And Disinfection Freouencxy sssenesesererssrrersrrrrrsrrrrrsrrrrrsrrrrrsnrrrsstrrrssnrrrsnnrrrsnrrrrsnrrersnsnrrnnne 47 Maintenance And Testing EE 48 Screen Messages And Troubleshooting AAA 49 Chapter 6 Technical Information i e cion ici bet 52 A Ag N An 52 EIMAN S reao a a connate ane cnun satiated eA EOE 53 Device Moratoria EE 55 EE d E 56 Chapter 1 Understanding Your Meter The EasyMax V Blood Glucose Meter Display Shows results D 2 messages and results EASYMax V stored in memory Battery Door Flip open the battery door by pushing the tab in the direction of the arrow and pulling the door up Power Button Press to confirm the setting M Button Press to enter 7 14 30 60 90 memory adjust setting and scroll through results C Button Press to enter memories adjust setting and scroll T
9. blood drawn from your arm by a healthcare professional Keep in mind that the lab could use different technology than EasyMax V blood glucose meter and that blood glucose meters for self testing generally read somewhat lower or higher than the lab result For accuracy and precision data and for important information on limitations see the instructions that come with your test strips 37 Chapter 4 Meter Memory Setup Memory Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test You can review them at any time When the memory is full the oldest result is dropped as the newest is added so it is very important to have the correct time and date set in the meter Meter Setup Using The Set Mode By using the set mode you can personalize your meter to suit your needs Here are the features you can customize Time and Date to set the time and date see Chapter 1 Language to set the language see Chapter 1 Volume to set the volume see Chapter 1 Note 1 2 Do not change your therapy based on one individual result in memory The memory is not lost when you replace the battery You do need to check that the time and date are still correct See Section Setting the time and date in Chapter 1 Once 480 results are in memory adding a new result causes the oldest one to be deleted If you don t set CtL mode control Solution values will be included in the
10. dings 93 10 The below substances up to the test concentration will not affect the test results Interfering Test Concentration Bias at 5015 Bias at 25015 Bias at 50015 Substance mg dL mg dL mg dL mg dL Acetaminophen Ascorbic Acid Gentisic Acid Methyldopa ea JA o e o a o 54
11. e level of less than 180 mg dL and a pre meal glucose of 70 130 mg dL Unusual Test Results If your test result doesn t match the way you feel please follow these steps 1 Run a control solution test Chapter 2 Control Solution Testing 2 Repeat a blood glucose test Chapter 3 Testing Your Blood glucose 3 If your test results still don t reflect the way you feel call your doctor immediately Reference American Diabetes Association Standards of medical care in diabetes Table 10 Diabetes care 2011 Vol 34 Suppl 1 S21 Note 1 Extremely high humidity may affect the test results A relative humidity above 90 may cause inaccurate results 2 Hematocrit below 30 may cause higher results Hematocrit above 55 may cause lower results 36 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results Your blood glucose can change quickly especially after eating taking medication or exercising If you test yourself in the morning then go to the doctor s office for a blood glucose test The results will probably not match even if you are fasting This is typically not a problem with your meter it just means that time has elapsed and your blood glucose has changed If you want to compare your meter result to the lab result you must be fasting Bring your meter to the doctor s office and test yourself by fingertip within five minutes of having
12. e results do not match how you feel please contact your healthcare professional immediately Remove batteries if the meter will not be used for one month or more Consult with your healthcare professional before testing on your palm or forearm Note Do not touch the strips with wet hands Do not use expired strips the expiration date is shown on the bottle Do not bend cut or twist the strips Up to the altitude of 10 000 feet has effect on readings Health Related Information If you are very dehydrated urinating frequently low blood pressure shock or hyperosmolar hyperglycemic nonketotic coma HHNKC you may get a test result that is lower than what your blood glucose really is If you think you are dehydrated call your doctor right away If you have followed the steps in the user s manual but still have symptoms that don t seem to match your test results contact your Healthcare Professional or physician immediately If you have questions regarding the use of the meter please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 OOAM 6 00PM During non service hours please contact your healthcare provider Please read your test strip instructions carefully for additional health related information Note EASYMax V MO ge ca DI UU Ad rc UR mmol L ai mg dL Ex ct Y 40 Before Meal AC After Meal PC Record Average E al Volume display Control Solu
13. eded to assure continuous 2 minute wet contact time Let the devices air dry for 30 seconds Disinfect at least once a week Do NW Make sure the meter is turned off during cleaning and disinfection E Keep the test strip vial tightly closed when performing the cleaning and disinfection procedures because the fumes from the disinfectant may affect the performance of the strip After cleaning or disinfection please perform the physical appearance and performance check of devices E Consult cleaning instruction of single use damp cloth 42 Do Not E Get any moisture in the test strip slot M Spray any cleaning solution directly onto the meter m Put the meter under water or liquid EW Pour liquid into the meter Meter cleaning area Lancing device cleaning area CI El IT E EE contact with blood contact with blood B_ BatteryCover low B Triggerbutton High C D Button High D Slidingbarrel High QE Cap High E Depthadjustring High G LE Strip Slot AST Cap 43 1 1 Physical Appearance check of the meter after each cleaning or disinfection Check item Accept Result Is the display screen clear Is there NO erosion on the strip slot or other parts es Action If any of the results are No the user should call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM for assistance 1 2 Performance check of the meter Acce
14. epeat step 1 to select P A or 24 mode and button to set the year the date then set the time P PM A AM 24 24hr Press power button to mode confirm the setting 18 Using EasyMax Blood Glucose Test Strip Use only with EasyMax Blood Glucose Meters Run a control solution test every time you open a new box of test strips See Chapter 2 Control Solution Testing Keep the test strips in their original bottle After you take a test strip out close the bottle immediately and make sure it has been closed tightly This keeps the test strips dry Use the test strip within three minutes after you take it out of the bottle The strip is for single use only Do not reuse it Record the date you open the test strip bottle Be sure to check the Expiration date on the test strip bottle The test strip is good for three months from the date the bottle is opened or until the expiration date on the bottle whichever comes first Store the test strip bottle and your meter in a cool dry place Store the test strips between 35 6 F 86 F 2 C 30 C Do not freeze Do not apply blood or control solution to the test strip until you insert it into the meter Do not touch the test strip with wet hands Do not bend cut or twist the test strips EasyMax Self Monitoring Blood Glucose Test System is a no code system and does not require any meter calibration 19 Chapter 2 Control Solution Testing Why Run A Control Solution T
15. est We recommend that you run EasyMax Control Solution Tests Such test will let you know that your meter and test strips are working properly to give reliable results You should run the control solution tests when You use the EasyMax V Blood Glucose Meter for the first time You open a new bottle of test strips You think the meter or test strips may be working incorrectly You drop the meter You have repeated a test and the test results are out of the range displayed on the bottle You are practicing the test procedure 20 About Control Solution Use only with EasyMax test strips Write the date you open the bottle on the bottle label The control solution is good for three months from the date the bottle is opened or until the expiration date on the bottle whichever comes first Do not use a control solution that is past the expiration date The control solution can stain clothing If you spill it wash your clothes with soap and water Close the bottle tightly after every use Left over control solution should not be added back into the control bottle Store the bottle of control solution at room temperature between 2 C 30 C 35 6 F 86 F Do not freeze If you would like to purchase EasyMax Control Solution s please contact your local dealer 21 Running A Control Solution Test You need the meter a test strip and control solution EASYMax wi 3 Place the meter on a flat surface like a tab
16. est Strip Slot through results A light shows you the direction Insert test strip here 14 The EasyMax V Accessories Blood Glucose Test Strip Test Strip Bottle Control Solution Bottle Electrode Strip Insert a Direction ue of the glucose oxidase is Asperg EASYMax 1 Hand Hold k 983112803 Wess Area Sait g Confirmation See Window Se Edge to Apply Expiration Sample Date 15 Lancing Device AST Lancing Device Cap Sliding barrel Sleeve Trigger button Hub Carrier Adjustable tip Installing Batteries 1 Open the battery door on the back of the meter by pushing the tab in the direction of the arrow and pulling the door up 2 Insert two batteries You will hear greeting music 3 Put the battery door back in place and snap it closed 16 Setting The Language And Volume First Time Use 1 Insert new batteries the meter 2 And press power button to 3 Repeat step 1 and 2 to set the turns on Press M button to select confirm the setting 8 volume 8 En or press C button to select ES En English ES Espanol Ry Note 1 The default language of the blood glucose meter is set in English 2 The unit of blood glucose meter is set at mg dL 17 Setting The Time And Date First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory 1 Press M button and C 2 Repeat step 1 to set 3 R
17. ew sterile lancet should be used one time you perform a test The lancing device lancets and meter are NOT to be shared between users or other family members Do NOT use on multiple individuals Sharing a lancing device and lancets may transmit bloodborne pathogens such as viral hepatitis All parts of the kit are considered biohazardous and may transmit infection even if you have performed cleaning and disinfection Wash hands thoroughly with soap and water after handling the meter or lancing device For further information please see FDA Public Health Notification Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens Initial Communication 2010 http www fda gov MedicalDevices Safety AlertsandNotices ucm224025 CDC Clinical Reminder Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens 2010 http www cdc gov injectionsafety Fingerstick DevicesBGM html Standard Accessories Full Kit Your new EasyMax V Blood Glucose meter and accessories work together to measure the amount of glucose in your blood The system includes e EasyMax V Blood Glucose Meter e AST Lancing Device Cap e EasyMax Test Strip 10 ct e User s Manual e Carrying Case e Test Strip Instructions e Alkaline Battery 2 ct e Log Book e Lancet 5 ct e Normal Control Solution e Lancing Device e Control Solution Instructions Optional Accessories e High Contr
18. le 4 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 1 Put a test strip into 2 The meter turns on 5 Squeeze the bottle until a the meter in the Press M button or C button to select CS press tiny drop forms at the tip of direction of the power button to confirm the control solution mode the bottle and place arrow L4 means control solution mode means solution on top of bottle before meal mode and E means after meal cap Note Setting the meter in control solution mode will prevent the control solution reading from being added to your memory and averages 22 6 Touch the drop on the bottle 8 Do not remove the test strip yet 10 Remove the test strip and throw to cap the tip of the test Check if the reading falls within the it away after you have compared strip range printed on the test strip bottle the reading to the range printed 7 The meter starts to count 9 Press power button to repeat the test on the test strip bottle down from 5 seconds and result Or you can also press C 11 Please check if the result on the then will display result button or M button to set the volume display is the same as audible before repeating the result result Note Be aware that there are normal high and low ranges listed on your test strip bottle The normal high and low refer to the three different control solutions that are available Please be sure that you are looking at the correct range
19. lease Insufficient blood Please try with a new strip with a new strip Temperature is too high and it may affect the test results HEEN Temperature is too low and it may affect l Temperature is too low the test results Turn off the meter Goodbye and power off music Note There is no speaking function for Viewing amp Deleting Test Results in the Chapter 4 Blood Glucose test result is BELOW the measurement range of 20 mg dL Table of Content Chapter 1 Understanding Your Meter 14 The EasyMax V Blood Glucose Meter aci is lia 14 The EasyMax NCCES A O AEA 15 MSAMI Batteries ua E 16 Setting The Language And Volume First Tmelse 17 Setting The Time And Date First TmeUse 18 Using EasyMax Blood Glucose Test Sips siii A EENS 19 Chapter 2 Control Solution Test ei ee eee ie cece 20 lee RUNA ee al Ee ele Tes E rssarescapaos ernesto odo eE reel ibas 20 ADOUL COMMON SOON cercar lindas 21 Running A Contra Eet 22 Understanding Control Test Res a 24 Chapter 3 Testing Your Blood Glucose 0 ccc ccccecccee ce eeeee eee eeeeeeseeeeeeeeeeeeeeseaeeeeesaeeeeeeseeeeessaaeeeeeaaeeeeeeas 26 Using the Lancing BREET 26 Inserting A Lancet into The Lancing Devin a teehee pelea eas 27 Running A Blood Glucose Test With Blood From Your Fingertip ccoccooccnccccccnnncncncnnonnncncnnnnnononnnnnnnnos 29 Alematle ole Testing er a a RN ee e 31 Running A Blood Glucose Test With Blood From Your Foream 33 Running A Blood
20. memory and averages Refer to the section Viewing amp Deleting Test Results to delete the control solution values before averaging your test results 38 Viewing amp Deleting Test Results The meter provides 7 14 30 60 and 90 days averaging to help track your blood glucose trend 1 Press power button to turn on the 3 Press C button to view 4 To delete a test result press C meter individual test result button for more than 3 seconds 2 Press M button to view averages for a e ae press power button to confirm 7 14 30 60 90 days ihe deletion Note 5 Press C button to keep 1 Press power button for 1 second and the meter will repeat reviewing the results the test results 6 Press M button to go back to 2 Press power button for 3 seconds to turn off the meter or averages for 7 14 30 60 90 days the meter turns off automatically in 90 seconds Chapter 5 Maintenance and Troubleshooting Installing Batteries The meter uses two alkaline 1 5V AAA batteries Batteries will normally last for more than 2000 tests Other types of 1 5V AAA batteries are also acceptable but the capacity of test times may differ Install the batteries when you first use the meter or replace with new batteries when the LP low power message and the low battery symbol appear on the display The meter will not turn on the first time batteries are installed Please press and hold power button or insert the test strip to turn your meter on
21. n and lets you know if something is wrong See Screen Messages and what to do about them To make sure the display is working properly turn off the meter Press and hold power button to see the complete display All the indicators should be clear and look exactly like the picture to the left If not please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM During non service hours please contact your local dealer 48 Screen Messages And Troubleshooting Never make treatment decisions based on an error message If you have any concerns call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM CITT YD a 2 Humidified Used strips Action Replace with a new strip D Li Low power System fault Action Replace with new Action Replace the batteries first If batteries ERROR 001 appears again please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM During non service hours please contact your local dealer 49 Memory fault Action Replace the batteries first If ERROR 005 appears again please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM During non service hours please contact your local dealer Test result is higher than 600 mg dL Action Test again If the result is still the same
22. ncet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing 3 Recap the front cap device firmly then twist off the protective cover Note Lancets are for single use only and a new sterile lancet should be used each time you perform a test 27 6 Set the lancing device aside until later in the test 5 Pull on the sliding barrel of the lancing device until it clicks and then release Now the lancing device is ready Do not prick your finger until your meter and strip are prepared 4 Select the desired penetration depth 1 Select 1 2 for soft or thin skin 3 4 for average and 5 6 for thick or calloused skin 2 Lancing device and lancets are not to be shared between users Sharing lancing devices and lancets may transmit bloodborne pathogens such as viral hepatitis Note 28 Running A Blood Glucose Test With Blood From Your Fingertip 1 Wash your hands with 2 Put a test strip into the meter in the A Place the lancing device against soap and warm water direction of the arrow The meter the pad of your finger Press the Rinse and dry thoroughly turns on Press M button or C button trigger button to activate the to select mode and press lancing device power button to confirm the setting 3 When the blood drop flashes on the display the meter will speak the instruction 29 Gently squeeze and or 6 Touch the blood drop at the tip of the
23. o the meter cleared for forearm for a few seconds activate the lancing device alternate site testing palm 3 Press and hold the device 6 Hold the device against forearm with a clear adjustable tip forearm and increase pressure until the blood against the forearm unti IC sample size is sufficient 33 Running A Blood Glucose Test With Blood From Your Palm 1 Massage the puncture area of 2 Press and hold the device 3 Press the trigger button to activate palm for a few seconds with a clear adjustable tip the lancing device against the palm 4 Hold the device against palm and increase pressure until the blood sample size is sufficient Note Check with your healthcare professional before test other sites than fingertip 34 Discarding Used Lancets 1 Unscrew and remove the 2 Without touching the used 3 Please discard used disposable cap lancet stick the lancet tip lancets according to the into its protective cover recommendations of your Grip the lancet carrier firmly healthcare professional Or and pull the lancet safely discard the used disposable out lancet into an appropriate sharps or biohazard container 4 After discarding wash hands thoroughly with soap and water Rinse and dry thoroughly 35 Expected Values The EasyMax Blood Glucose test strips are whole blood referenced and calibrated for easier comparison to lab results The American Diabetes Association recommends a post meal glucos
24. ol Solution e Low Control Solution Note 1 Normal control solution is included with the system 2 High Low control solution is available For purchase please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00 AM 6 00PM During non service hours please contact your healthcare provider Standard Accessories Meter Only Your new EasyMax V Blood Glucose meter and accessories work together to measure the amount of glucose in your blood The system includes e EasyMax V Blood Glucose Meter e Carrying Case e Alkaline Battery 2 ct e User s Manual s Log Book Optional Accessories e High Control Solution e Normal Control Solution e Low Control Solution Note 1 High Normal and Low control solutions are available For purchase please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM During non service hours please contact your healthcare provider Why is it so important to test blood glucose regularly Testing your blood glucose regularly can make a big difference in how you manage your diabetes every day We ve made this SMBG system as simple as possible to help you to use the meter regularly Your meter is easy to use and you can adjust the lancing device for your comfort Do you need Help If you have questions or need assistance please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time
25. pt After each cleaning 1 Press and hold power Is meter powered on button for 3 sec Voren 44 After each disinfection 1 Insert test strip Is meter powered on 2 Apply control solution Any reading Is the reading within control range 3 Remove test strip Is meter powered off 4 Press and hold power Is meter powered on button for 3 sec Does meter beep 5 Press and release C or Is it correctly stored in the memory M button Does the result read clearly Action If any of the results are No stop using the device Please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM for replacement with a new meter 2 1 Physical Appearance check of the lancing device after each cleaning or disinfection Check item Accept Result is there NO erosion on any parts Action If any of the results are No the user should call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM for assistance 45 2 2 Performance check of the Lancing device fm E ren E After each cleaning Can the cap be screwed on the lancing device Yes 2 Pull on the sliding barrel and then Can the lancing device click Yes release 3 Press trigger button Can the lancet be fired Yes DEE D each disinfection 1 1 Install the lancet on the lancet holder the lancet on the lancet holder Can the lancet be fixed on the lancet holder Yes 2 Cap
26. the AST cap to the lancing device Can the AST cap be screwed on the lancing Yes device 3 Remove the AST cap Recap the normal Can the cap be screwed on the lancing device Yes cap to the lancing device Can the penetration depth ring be adjusted Yes 4 Pull on the sliding barrel and then Can the lancing device click Yes release Can the lancet be fired Yes Action If any of the results are No please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM for replacement with a new device 46 Cleaning And Disinfection Frequency At least 14 600 validated cycles for the meter and lancing device were done and 10 000 cycles of cleaning and 4 600 cycles of disinfections were included 4 cycles of cleaning per day and 1 cycle of disinfection per week allow the user to use the device for 4 years Cleaning Frequency 4 cycles day X 365 days year X 4 year warranty 5840 cycles of cleaning lt 10 000 validated cycles of cleaning Disinfection Frequency 1 cycle week X 52 weeks year X 4 year warranty 208 cycles of cleaning lt 4 600 validated cycles of disinfection 4 year warranty for properly cleaning and disinfection After 4 years the meter must be replaced with a new meter 47 Maintenance And Testing Hna d d N LI mmol L mg dL Siet E 4 Your meter needs little or no maintenance with normal use lt automatically tests its own systems every time you turn it o
27. tion Insert strip Temperature When ER shows up in any section of user s manual the meter will sound and tell you the instructions Description of Sound Please run the setting English En Espa ol ES l Please flag the test Before meal please confirm After meal Before applying blood to the meter l i i please confirm Control solution please confirm When the meter is ready to apply blood Please apply blood into the strip Blood Glucose test is complete and the result is shown on screen Humidified Used strips Humidified or used strips Please replace with a new strip Low Power Low power Please replace with new batteries Blood glucose is number milligram per deciliter WHEN the meter will speak WHAT the meter will say Unable to measure Test result is higher than 600 milligram per Blood Glucose test result is ABOVE the a l H g H deciliter Please test again and if you get the same result measurement range of 600 mg dL please contact your healthcare professional immediately Unable to measure Test result is lower than 20 milligram per deciliter Please test again and if you get the same result please contact your healthcare professional immediately Press C button to delete a memory Please confirm the deletion Memory was deleted Memory deleted 7 14 30 60 90 a average is number milligram per deciliter If the blood is not If the blood is not enough Insufficient blood P
28. try a control solution test and if the control solution test falls within the correct range please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 OOAM 6 00PM During non service hours please contact your healthcare provider 50 The test result is lower than 20 mg dL Action Test again If the result is still the same try a control solution test and if the control solution test falls within the correct range please call the Customer Care Service toll free at 866 994 3345 Eastern Standard Time Mon Fri 8 00AM 6 00PM During non service hours please contact your healthcare provider The Ht and thermometer icon appears Temperature is too high outside the required range of 50 F 104 F 10 C 40 C This alerts users that an incorrect result may occur if the test continues Action Relocate the meter to a location with temperature between 50 F 104 F 10 C 40 C 51 L a A pa The Lt and thermometer icon appears Temperature is too low outside the required range of 50 F 104 F 10 C 40 C This alerts users that an incorrect result may occur if the test continues Action Relocate the meter to a location with temperature between 50 F 104 F 10 C 40 C Chapter 6 Technical Information Specifications Brand name EasyMax V Blood Glucose Meter Range 20 600 mg dL Test time 5 seconds Memory sets 480 test resul
29. ts D Temp 50 F 104 F 10 C 40 C Operating condition Relative Humidity R H lt 90 0 6 uL Blood sample Fresh blood from fingertip palm or forearm Hematocrit Hct 30 55 Power 2 Alkaline 1 5V AAA Display dimension Device dimension H x W x D mm Es Principles Electrochemical biosensor technology 52 Limitations The test strips are used for fresh capillary whole blood samples 1 2 3 4 al DO NOT use neonate blood sample Not to be used for diagnosis or screening of diabetes Alternate site testing with this system can be used only during steady state blood glucose conditions Measurements from alternate site testing should never be used to calibrate a continuous glucose monitor CGM or entered into insulin dose calculators for insulin dosing recommendations Extreme humidity may affect the results A relative humidity greater than 9 may cause incorrect results The system should be used at a temperatures between 50 F and 104 F 10 C and 40 C Outside this range the system may get incorrect results DO NOT reuse the test strips The test strips are for single use only Hematocrit The hematocrit between 30 and 55 will not significantly affect the results Hematocrit below 30 may cause higher results Hematocrit above 55 may cause lower results If you do not know your hematocrit level please consult with your healthcare professional Up to the altitude of 10 000 feet has effect on rea
Download Pdf Manuals
Related Search
Related Contents
Zanussi ZCM 630 Instruction Booklet Eye Stretcher EOT-1800 Ezer 取 扱 説 明 書 Premium Design Solar Charger 2U\d TbYfU deb^dQR\U - CONRAD Produktinfo. Arquivos de Dados - Apostilas técnicas Manuale utente - Audiovideosorveglianza Mode d`emploi avis d`appel public à la concurrence Manual Descargar - Hitachi Copyright © All rights reserved.