Home

The Mini Automated Cell Counter

image

Contents

1. Moxi The Mini Automated Cell Counter User Manual The information in this document is subject to change without notice and should not be construed as a commitment by ORFLO Technologies a DBA of E I Spectra LLC Neither Orflo Technologies nor any of its affiliated corporations assumes responsibility for any errors that may appear in this document This manual is believed to be complete and accurate at the time of publication In no event shall Orflo Technologies or any of its affiliated corporations be liable for incidental or consequential damages in connection with or arising from the use of this manual CE 2011 ORFLO Technologies a DBA of E I Spectra LLC All rights reserved Rev 2 06 2011 The ORFLO symbol and Moxi are trademarks of E I Spectra LLC registered in the U S and other countries Windows Windows XP Windows Vista and Windows 7 are trademarks of Microsoft Corporation registered in the U S and other countries Mac and Mac OS are trademarks of Apple Corporation registered in the U S and other countries Bluetooth and the Bluetooth logos are registered trademarks of Bluetooth SIG Inc registered in the U S and other countries Accutase is a registered trademark of Innovative Cell Technologies TUV S D and the T V SUD symbol are registered trademarks of TUV S D Aktiengesellschaft Contents UOC WG ON En nee ae nas done dt don da ae te nues 1 symbols Used in This User Guide ss 1 SO SCOR SE
2. ae ee 2 Bonsianes TS SSCG Es ne ace alent ace tente io noise acceded 3 Moxi Z Mini Automated Cell Counter Kit sise 4 Moxi Z Mini Automated Cell Counter Accessories ss 5 AR LEV S 6 General Guidelines sn seriellen 6 Matenlals Requlfed nes ee ee are 7 Using the Moxi Z Automated Cell Counter sn 7 SE NOS ee see 7 Gro 9 11 110 element womens erst et mrt ee ee 7 Managing the Dalai a ae 8 Metrieving and Deleling Dalaran u 9 MOXA HE Dre E E EN 11 Installing MoxiChart Software on a PC 11 Connecting to Moxi Z via Bluetooth with a PC 12 Installing MoxiChart Software on a Mac 13 Connecting to Moxi Z via Bluetooth with a Mac VU 13 Moxi Z Automated Cell Counter Calibration Check 14 Instrument Firmware and Software Upgrades nenn nenne nennen 14 Updating Moxi Z Te W ANG nn 14 TOUDIGSMOOUNG usa er re 15 Maint nance and Storage ee elek 17 Specifications for the Moxi Z Automated Cell Counter 18 Ord rino IHformallon ass tieren een 19 Technical SOLVIC 0 cc cccccccccccccececcccccccecececcaccceceteceaeuecetaneaeueteteceaeauscetaneaeauscetaceceausnstaeceanscs 20 Warranty Introduction The ORFLO Moxi Z Mini Automated Cell Counter performs cell count size and viability measurements for particle sizes 2 34 microns It combines the gold standard Coulter Principle with a patented thin film sensor technology to deliver highly accurate and repeatable results in just 8 s
3. curve fit count on a diameter scale of 2 34 um If desired touch the ReScale icon to display the results at a higher resolution This is recommended when counting smaller cells or particles Successively pressing the ReScale icon will reduce the diameter scale through the following ranges 2 34 2 26 2 20 and 2 10 um This feature is only available immediately following a cell count Touching the ReCalc icon at any time will reset the diameter scale to 2 34 um Touching the Done icon will save the current histogram TEST 01 12 12 8 Cells ar 35 359 1 di Lt C i A i A n n p le 8 Ce Cells u 9 2 un yeter 98 Total V 8 Total Cells 1 55 p ume v vV T ye ReCalc ReScale plete PAT 1 55 Done ReScale Dor De Moxi Z Mini Automated Cell Counter User Manual Page 8 2 The histogram can also be gated manually by touching the Curve Fit Count results button Gating markers can then be positioned as desired by sliding each blue gating marker independently Only the cells between the markers are counted Touching the Gated Count results button will return the display to curve fit mode 6 14 03 TEST 01 Curve Fit Count 12 8Ce 1 4 UM cola 1 55 pl volume 2 8 Leils u lameter ta jolume R Zo D Delete s u 3598 Total Cells um diameter 3 2 um d 55 pL v elete oom LE Done teCalc i m 3 Press the Delete icon at any time to permanently delete the results of the test 4 Press the Done icon
4. screen anywhere to start ORFLO Fed Histograms SetM s BlueTooth Help 2 Run MoxiChart application and click on a Bluetooth icon in upper right corner 2 GER RS HERAN cL Moa e e Mo 6 wu dons pr ORFLO mars De mn Mont tt Sa ass a home pm te rt ow ow ot ms Le Ds moe eng ste Pat Pee n te mt Pe mms md we dupe Le gt D fe ret emam vo aus bet os wein ie ewe riu jo No Ore eher owe e 3 Choose the device which corresponds to the Moxi Z 2 LP Adda device Select a device to add to this computer Windows will continue to look for new devices and display them here R Brother MFC 8480DN Desktop computer ld 001ba94ccc0b Bluetooth Web Services Desktop computer a BluelMod P2x G2 80 E3 Desktop computer A Bluetooth Bluetooth Other _ Desktop computer 7a Other Bluetooth Other What if Windows doesn t find my device 4 Select a folder to upload data files to Moxi Z Mini Automated Cell Counter User Manual Page 12 Installing MoxiChart Software on a Mac 1 Insert Moxi Z flash drive into a USB port on your computer mr 2 Open the folder for the USB drive 3 Double click on the on the file MoxiChartinstaller dmg 4 Drag and drop MoxiChart into your applications us Dur folder O ORFLO Applications MoxiChart 5 From the applications folder select MoxiChart to launch the application Connecting to Moxi Z via Bluetoot
5. Cable amp Power Adapter USB Flash Drive with software Calibration Check Beads Electronic Calibration Cassette sold separately Moxi Z Mini Automated Cell Counter User Manual Page 5 Part Function Cassette Dispenser Stores up to 25 cassettes for convenient dispensing USB Cable Connects instrument to PC Mac or power adapter Power Adapter Connects USB cable to an AC outlet US and EU models only USB Flash Drive Stores Moxi Z software and user manual Calibration Check Beads Polystyrene beads for confirming proper system operation and calibration Electronic Calibration Cassette Electronic cassette for verifying proper system sold separately operation and calibration Installation The Moxi Z is shipped in a condition ready for initial use with the battery partially charged If necessary the battery can be charged by inserting the USB cable into the USB Cable Port and connecting the cable to a computer or power adapter If using a power adapter insert the plug into an AC outlet 110 220 V The battery will be fully charged in approximately four hours Note For optimal cell counting results perform cell counts with the USB cable disconnected Although the unit may be operated using AC power this mode may cause undesirable electrical noise which could result in less accurate small particle counting results and may affect MVI When not in use the Moxi Z should be connected to a charging source so that the battery will maintai
6. Ensure the cells are in a single cell suspension Break Cell clumping clumps by pipetting up and down with a standard pipette ORFLO recommends Accutase or equivalent Try running the cell sample at a higher concentration Cell concentration too low Refer to Managing the Data section for instructions on Peak of interest indistinct adjusting the Y axis Internal firmware issue due to instrument Reset instrument by pressing and holding the power Instrument stops respondin button for at least 5 seconds If problem persists j j j malfunction OF MIJN EVE return instrument for service of external interference Battery is faulty or has Battery will not fully charge surpassed its service life Return instrument for battery replacement Moxi Z Mini Automated Cell Counter User Manual Page 15 r Warnin i i Error Warning Cause Corrective Action Messages Viscous sample e g Use ORFLO Diluent or PBS to dilute sample serum enriched media Sample concentration is too high dilute cell sample more blocked Ensure that cells are in a single cell suspension Break clumps by pipetting up and down with a standard pipette Wrong diluent Use ORFLO Diluent or PBS Sample volume too small Lost start or air bubble in test Make sure sample volume is 75 uL cassette Cell Counter sensor is Aperture block Do not remove cassette from Cell Counter before completion of counting cycle Ensure cassette is properly inserted Sensor n
7. al Service For technical service contact ORFLO Technologies at 425 806 0002 or email us at info orflo com Warranty ORFLO Technologies Orflo warrants that its products will meet their applicable published specifications when used in accordance with their applicable instructions for a period of one year ORFLO MAKES NO OTHER WARRANTY EXPRESS OR IMPLIED THERE IS NO WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The warranty provided herein and the data specifications and descriptions of Orflo products appearing in Orflo s product literature may not be altered except by expressed written agreement signed by an officer of Orflo Representations oral or written which are inconsistent with this warranty or such publications are not authorized and if given should not be relied upon In the event of a breach of the foregoing warranty Orflo s sole obligation shall be to repair or replace at its option the applicable product or part thereof provided the customer notifies Orflo promptly of any such breach If after exercising reasonable efforts Orflo is unable to repair or replace the product or part then Orflo shall refund to the customer all monies paid for such applicable product or part ORFLO SHALL NOT BE LIABLE FOR CONSEQUENTIAL INCIDENTAL SPECIAL OR ANY OTHER DAMAGES RESULTING FROM ECONOMIC LOSS OR PROPERTY DAMAGE SUSTAINED BY ANY CUSTOMER FROM THE USE OF ITS PRODUCTS O ORFLO Moxi Z Mini Aut
8. d and certified by T V S D Product Service Division Moxi Z Mini Automated Cell Counter User Manual Page 1 Safety Precautions Please review and understand the safety instructions below before operating the Moxi Z Cell Counter A WARNINGS e o avoid danger of electric shock do not install the instrument in an area with a high humidity level such as a greenhouse or an incubator Refer to Operating Environmental Conditions in Specifications section e Do not touch the USB cable or USB charging adapter with wet hands e o avoid a potential shock hazard choose the correct plug configuration and make sure that the USB cable and USB charging adapter are plugged securely into a properly grounded AC power outlet Make sure that the connection between the USB cable and the instrument is secure e Always ensure that the power supply input voltage matches the voltage available in your location e Do not use with flammable or explosive liquids e Do not immerse instrument body in liquid or allow liquid to enter any part of the instrument CAUTION e Do not expose instrument to vibrations Vibrations may cause instrument malfunction or damage e Do not autoclave or expose to high temperature e Use only authorized accessories universal power adapters USB cable e lf the instrument is dropped and broken disconnect the USB cable and contact Orflo Technologies Do not attempt to disassemble the instrument Moxi Z Mini Au
9. econds The instrument is ultra small and runs on a rechargeable battery making it ideal for use in a hood Cell concentration average cell volume average cell diameter and the Moxi Viability Index MVI are displayed for each sample Test results are also displayed in the form of a histogram The Moxi Z unit can store approximately 500 histograms and if desired the data may be downloaded to a PC or Mac via a Bluetooth wireless connection The system is intended for research use only and has been tested with cell types that are representative of those commonly used The Moxi Z Mini Automated Cell Counting system is designed and manufactured by Orflo Technologies a DBA of E I Spectra LLC 18916 North Creek Parkway Building 2 Suite 105 Bothell WA 9801 1 www orflo com Symbols Used in This User Guide The following symbols are used throughout this user guide and or on product labels The user is responsible for operating the product in accordance with the indicated requirements Symbol Warning alerts you to actions that may cause personal injury or pose a physical threat X Do not discard with common solid waste at end of life Segregate with other waste electrical and electronic equipment WEEE and send to an appropriate facility for recycling Affixed in accordance with European Council Directives 2004 108 EC electromagnetic compatibility and 2006 95 EC safety requirements S O AS ES YD TUV Safety teste
10. f necessary dilute a cell suspension with ORFLO Diluent or an appropriate diluent so that the cell concentration is within the operating range of the instrument 3 000 to 500 000 cells mL For optimal MVI performance run samples at concentrations between 50 000 cells mL and 350 000 cells mL A dilution of 1 5 to 1 20 is recommended for most mammalian cell lines but the appropriate dilution will depend on cell type and seeding density The volume required for an accurate count is approximately 75 uL Turn the Cell Counter on by pressing the power button and the Home screen will be displayed Histograms Settings BlueTooth Help Press the tray down and insert a Cassette into the Moxi Z The Pipette 75uL Sample screen will be displayed Moxi Z Mini Automated Cell Counter User Manual Page 7 4 Pipette a 75 uL sample into the fill port of the cassette either y test 1 or test 2 depending on which end of the cassette was inserted into the instrument Touch the screen anywhere to start The Moxi Z will begin the test and the histogram count results will be complete in approximately 8 seconds The Curve Fitting and MVI calculations begin automatically and require only a few additional seconds The results will then automatically be displayed on the screen e 3 2 um di ota 1 55 pL vo ReScale 1 ameter 3 lume D Delete Curve Fi 28Ce 5981 one Managing the Data 1 The results are initially displayed for a
11. h with a Mac The procedure for connecting Moxi Z via Bluetooth with a Mac is the same as that for a PC See the section entitled Connecting to Moxi Z via Bluetooth with a PC on page 12 Moxi Z Mini Automated Cell Counter User Manual Page 13 Moxi Z Automated Cell Counter Calibration Check The Moxi Z Automated Cell Counter can be tested periodically with the included Calibration Check Beads The beads can be used to test the system as well as for practice and troubleshooting The bead size and concentration are specified on the vial containing the beads In addition proper system operation and calibration can be verified using an Electronic Calibration Cassette Cat No MXA004 sold separately Refer to the product instructions included with the Electronic Calibration Cassette for guidelines on its use Instrument Firmware and Software Upgrades Moxi Z Automated Cell Counter firmware and software may be updated periodically For information on the most up to date firmware and software contact ORFLO Technologies at www orflo com Register your instrument in order to receive notification about relevant firmware and software upgrades Updating Moxi Z Firmware The Moxi Z firmware can be updated through a Bluetooth connection The user first needs to out the Moxi Z into a firmware update mode This can be done in either of the following two ways With the unit powered off quickly press the power reset button four times When succe
12. ll Counter User Manual Page 16 Disk full Delete histograms or download to computer Disk now full Maintenance and Storage Storage Store the Moxi Z Cell Counter and Moxi Z Test Cassettes at room temperature in a dry environment Avoid exposure to ultraviolet light as it may discolor and or damage the instrument Charging the Battery The Moxi Z Automated Cell Counter contains a 3 7 V lithium ion battery which can be charged for approximately 500 cycles The battery may be charged at any time in the discharge cycle and can be charged continuously without damage using a PC Mac or the power adapter Refer to the Installation section for information on how to charge the battery CAUTION To prevent battery damage use ONLY the specified power adapter Cat No MXA002 or MXA003 or the USB port of a computer The battery life is about 2 to 5 years depending on use Lithium ion batteries discharge even if they are not in use To prevent battery damage from self discharge charge the battery at least once every two months Cleaning Sanitizing The Moxi Z Cell Counter is NOT autoclavable Extreme heat will damage the battery touch screen display and other electronic components The external surfaces of the Moxi Z Cell Counter body and touch screen display can be sanitized by wiping with a soft nonabrasive cloth moistened with 70 isopropyl alcohol IPA or 70 ethanol Do not clean the instrument with any more aggre
13. n a continuous charge and be ready for immediate use If a low battery warning appears on the display stop using the instrument and charge the battery or operate the Moxi Z using an AC power source General Guidelines The Moxi Z Mini Automated Cell Counter is used with the Moxi Z Cassette Refer to the Specifications section for information on the operating ranges for the system The sample volume for a test should be 75 uL If necessary prepare dilutions of the sample using ORFLO Diluent Cat No MXA006 or a diluent compatible with the characteristics of the cells The diluent used should not cause changes in the cell size and should have sufficient conductivity to enable operation of the instrument Water hypotonic or hypertonic solutions are not acceptable diluents Moxi Z Mini Automated Cell Counter User Manual Page 6 Note Detergents and DMSO may interfere with cell counting 10 DMSO is not an acceptable diluent but 1 DMSO may be used Serum enriched media may also interfere with counting Dilute samples with ORFLO Diluent or PBS rather than serum enriched media Materials Required Cell sample diluted if necessary 75 uL minimum Pipette and appropriately sized pipette tips Using the Moxi Z Automated Cell Counter Settings Set the date and time by pressing the Settings icon on the main menu of the Moxi Z Then use the arrow keys and follow the instructions displayed on the screen Cell Counting 1 I
14. omated Cell Counter User Manual Page 20
15. ot properly Lost sensor detect inserted into cell counter Make sure concentration of cell sample is within recommended guidelines Refer to General Guidelines section Concentration of cell Warning High Concentration sample is too high Start open Stop open Issue detected upon test Reinsert sensor If problem persists return instrument Start stop short cassette insertion for service Electrode short Previously used sensor Battery needs to be Recharge instrument for a minimum of 4 hours or use Low battery recharged instrument with AC power Instrument has exceeded maximum storage capacity of 500 histograms After histogram is recorded and saved Delete files there is no more space on the disk drive Internal firmware issue Clear error by turning instrument off and then on again due to instrument Remove cell counter from sources of external Unhandled exception malfunction or high level interference If problem persists return instrument for of external interference service SPI timeout Instrument malfunction If problem persists return instrument for service Corrupt filesys Instrument malfunction If problem persists return instrument for service Instrument has detected corruption or new version Defaults loaded of firmware and reset all If problem persists return instrument for service settings to factory defaults False start Sensor malfunction Use new sensor False stop Moxi Z Mini Automated Ce
16. ptateurs de courant universels cable USB Si l instrument est chapp et bris d brancher le cable USB et communiquer avec Orflo Technologies Ne pas tenter de d sassembler l instrument Moxi Z Mini Automated Cell Counter User Manual Page 3 Moxi Z Mini Automated Cell Counter Kit The Moxi Z Mini Automated Cell Counter kit includes the Moxi Z instrument USB Cable Power Adapter US and EU versions only Cassette Dispenser Calibration Check Beads USB Flash Drive with software user guide and 25 Cassettes 2 tests per cassette Touch Screen Display Cassette Tray Power Reset Button USB Cable Port Cassette Test 2 Fill Port Test 1 Fill Port Cassette Moxi Z Mini Automated Cell Counter User Manual Page 4 Part Touch Screen Display Power Reset Button Cassette Tray USB Cable Port Cassette Function Allows user to interface with instrument Displays all information needed for operation Displays test results and histograms with curve fitting gating cell volume concentration diameter and Moxi Viability Index MVI Turns Moxi Z on and off Resets the unit when pressed and held for gt 5 seconds Tray that needs to be pressed down for inserting cassette Connects instrument to USB cable Disposable used for loading samples Each cassette contains two ports thereby allowing for two samples to be run per cassette Moxi Z Mini Automated Cell Counter Accessories Cassette Dispenser USB
17. ssful the white Moxi Z screen will display with text under the Moxi Z logo that M xi indicates the system is in firmware update mode If shld unsuccessful turn the power off and retry nul OR Alternatively the firmware update mode can be entered from the Help menu screen On the displayed image touch the power button of the Moxi Z and the system will display a blue screen with a message that reads System is loading If unsuccessful the second page of the help menu is entered and the user must return to the previous page with the back arrow and retry Moxi Z Mini Automated Cell Counter User Manual Page 14 From here open MoxiChart and select Update Firmware from the Tools menu Follow the instructions in the installation wizard to complete the firmware update Troubleshooting Symptom Corrective Action Questionable Concentration of cell Make sure concentration of cell sample is within concentration sample is too high or too recommended guidelines Refer to General low Guidelines section Use a diluent that is compatible with cells being Wrong diluent counted ORFLO Diluent Cat No MXA006 or equivalent Ensure the cells are in a single cell suspension Break Cell clumping clumps by pipetting up and down with a standard pipette ORFLO recommends Accutase or equivalent Questionable cell diameter Use a diluent that is compatible with cells being Wrong diluent counted ORFLO Diluent Cat No MXA006 or equivalent
18. ssive solutions CAUTION When sanitizing make certain that no liquid enters any internal cavities of the instrument Maintenance There is no routine maintenance required for the Moxi Z Automated Cell Counter In addition there are no user serviceable parts Instrument repairs must be carried out by authorized personnel only Moxi Z Mini Automated Cell Counter User Manual Page 17 Specifications for the Moxi Z Automated Cell Counter Performance Sample Volume Required Operating Range Cell Size Cell Concentration Test Time Software Dimensions Length Width Height Weight Electrical Specifications Internal Battery AC Power Adapters US and EU types 75 uL 2 34 um 3 000 500 000 cells mL 50 000 350 000 cells mL recommended for optimal MVI calculation 8 seconds PC or Mac compatible requires Windows XP Windows Vista Windows 7 or Mac OS X operating system 7 6 in 19 3 cm 4 3 in 13 5 cm 2 8 in 7 1 cm 1 5 lbs 680 g Rechargeable 3 7 V 4400 mAh lithium ion battery Input 100 240 VAC 50 60 Hz 0 2 A Output 5 V 1 A CE certified Operating Environmental Conditions Temperature Maximum Relative Humidity 15 30 C 20 80 non condensing Moxi Z Cassette Specifications Type M Material Aspiration Volume Dimensions Weight Polyester 75 uL Length 3 3 in 8 4 cm Width 1 2 in 3 0 cm Height 0 035 in 0 90 mm 0 1 oz 2 3 g Moxi Z Mini Automated Cell Co
19. ted Cell Counter User Manual Page 10 Moxi Z Help 1 For help with operation of the Moxi Z press the Help icon on the Home screen Visual instructions for inserting a cassette will be presented 2 Press the Next icon to view the next visual instruction that demonstrates how to pipette a sample into the cassette 3 Press the Next icon to proceed to the next instruction screen or press the Previous icon to return to the previous screen 4 Press the Done icon to exit the help screens and return to the Home screen For additional help see the Troubleshooting table page 15 Installing MoxiChart Software on a PC 1 Insert Moxi Z flash drive into a USB port on your computer 2 If prompted to run MoxiChart Install click YES and follow the on screen Welcome to the MoxiChart Setup instructions Otherwise open ORFLO Wizard DISK folder and run MoxiChart Install This wil install Moxichart on your computer It is recommended that you close all other applications before continuing Complete the setup by following the instructions of the MoxiChart Setup Wizard Click Next to continue or Cancel to exit Setup Moxi Z Mini Automated Cell Counter User Manual Page 11 Connecting to Moxi Z via Bluetooth with a PC 1 Press the Bluetooth icon to display the unit s Bluetooth D System is Ready To perform a count 1 Insert cassette into Moxi Z 2 Pipette 7SuL of sample into the cassette 3 Touch
20. to save the results and return to the Home screen Retrieving and Deleting Data System is Ready 1 To open a saved test press the Histogram icon on the Home screen th ort en 2 Pipette 75uL of sample into the cassette 3 Touch screen anywhere to start ORFLO Histograms Settings BlueTooth Help 2 Icons for up to nine saved histograms will be displayed on the screen Press the appropriate icon for the test of interest or press the Page Up or Page Down icon to view more test results Moxi Z Mini Automated Cell Counter User Manual Page 9 3 If desired press the Curve Fit Count results button Gating markers can then be positioned as desired by sliding each blue gating marker independently From the gated results screen touch the Gated Count results button to return to the results for curve fit mode a SZU damer EEA Curve Fit Count Gated Count 3 2 un 1 55 pL v om room ri 4 Press the Zoom and Unzoom icons to adjust the vertical scale of the histogram Done Unzoe 5 Press the Delete icon to permanenily delete the results of the test 6 Press the Done icon to close the test results and return to the Home screen note zoomed view will not be saved System is Ready To perform a count 1 Insert cassette into Moxi Z 2 Pipette 75uL of sample into the cassette 3 Touch screen anywhere to start ORFLO Histograms Settings BlueTooth Help Moxi Z Mini Automa
21. tomated Cell Counter User Manual Page 2 Consignes de s curit Veuillez lire et vous assurer de comprendre les consignes de s curit ci dessous avant d utiliser le compteur Moxi Z Cell IN AVERTISSEMENTS e Afin d viter tout danger de choc lectrique ne pas installer l instrument dans un endroit ou le taux d humidit est lev comme dans une serre ou un incubateur Se reporter la section sur les sp cifications en mati re de conditions environnementales d exploitation e Ne pas toucher au c ble USB ou l adaptateur de charge USB les mains mouill es e Afin d viter tout risque de choc lectrique choisir la configuration de prise appropri e et s assurer que le cable USB et l adaptateur de charge USB sont bien branches dans une prise de courant CA mise a la terre S assurer que la connexion entre le cable USB et l instrument est bien tablie e Toujours s assurer que la tension d entr e du bloc d alimentation correspond a la tension disponible dans votre lieu e Ne pas utiliser avec des liquides inflammables ou explosifs e Ne pas immerger le corps de l instrument dans du liquide ou permettre a du liquide de p n trer dans l instrument ATTENTION e Ne pas exposer l instrument des vibrations Les vibrations peuvent causer le dysfonctionnement de l instrument ou des dommages celui ci e Ne pas autoclaver ou exposer des temp ratures lev es e Utiliser uniquement les accessoires autoris s ada
22. unter User Manual Page 18 Ordering Information This section lists catalog numbers for the Moxi Z Automated Cell Counter and related products You can purchase Orflo products through a regional distributor or on line at www orflo com See the Technical Assistance section for information about contacting Orflo Product Description Moxi Z Mini Automated Cell Counter Kit U S Version includes Cell Counter Cassette Dispenser USB Cable USB Power Adapter Calibration Beads Cassettes 25 pk and flash drive with software and manual Moxi Z Mini Automated Cell Counter Kit E U Version includes Cell Counter Cassette Dispenser USB Cable USB Power Adapter Calibration Beads Cassettes 25 pk and flash drive with software and manual Moxi Z Mini Automated Cell Counter Kit International Version includes Cell Counter Cassette Dispenser USB cable Calibration Beads Cassettes 25 pk and flash drive with software and manual Cassettes Type M Cassette Dispenser USB Cable and Power Adapter US version USB Cable and Power Adapter EU version Electronic Calibration Cassette Calibration Check Bead Kit ORFLO Diluent 100 ml USB Power Cable Cat No MXZ001 MXZ002 MXZ003 MXC001 MXC002 MXA001 MXA002 MXA003 MXA004 MXA005 MXA006 MXA007 Quantity Pack 1 25 pk 50 tests 10 x 25 pk 500 tests 4 4 Moxi Z Mini Automated Cell Counter User Manual Page 19 Technic