1. least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on and off position N With the UPS unit off and unplugged connect the computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit o Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords Depress the power switch to turn the unit on The power on indicator light will illuminate and the unit will beep on If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on D Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet t
2. berPower Reliability Quality Value DL450ELCD DL650ELCD DL850ELCD User s Manual IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover There are no user serviceable parts inside CAUTION To avoid electrical shock turn off the unit and u
3. he battery will automatically recharge N To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery life BASIC OPERATION DESCRIPTION Schuko Power On Off Switch Press the power switch to turn the UPS ON or OFF LCD Function Selected Switch Press the LCD function selected switch to know the UPS status LCD Display The LCD will display the UPS status including input voltage output voltage runtime percentage of load and battery etc AC outlet The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges 8 and spikes USB Port to PC Input Circuit Breaker The Circuit Breaker provides optimal overload protection DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Indication ae neUT pa Pir ZEBE sa lal k UPS Status Display Line mode Capacity Display Digital Value Display Select SW Load Battery Input Output Run ms ejm E a eee e tte Site fee st ah Se V X V S eee X oth Return V xX X v x Press gt 3sec Sound Disable Oy ee ee y ESEIEZEI ES ETE EEE Es Press gt 3sec again V X X X Sound Enable Overoad V X 1V Il Il Il V Il
4. luminated X Not Illuminated Either Battery mode UPS Status Display Capacity Display Digital Value Display Select SW Load Battery Input Output Run res Ojama ae ee es toe e aah a Oo S vy ee O Initial X V o X X UCU ae E Oooo SX VS o S X X S Ne ad X NV o y X S S S N E a 4th ee ee oth Return OX Sovy J ee S o X E u Es X ress gt 9SeC Sound Disable Press gt 3sec again X V X Sound Enable Overoad X v v V Illuminated X Not Illuminated TECHNICAL SPECIFICATIONS DL450ELCD DL650ELCD DL850ELCD Capacity VA Capacity Watts 47 63Hz Auto Sensing Either Frequency Range Simulated Sine Wave at 230Vac 7 50 60HZz 1 On Utility Circuit Breaker and Internal Current Limiting On Battery Output Voltage On Battery Output Frequency Overload Protection On Battery Internal Current Limiting Surge Protection Lightning Surge Protection Yes Physical Total of UPS outlets Maximum Dimensions DxW xH Weight kg Battery 3 Battery Backup amp Surge Protected Outlets 235 x 90 x 190mm 12V 3 6Ah x1 12V 4 5Ah x1 8 hours Sealed Maintenance Free Lead Acid Battery 12V 7Ah x1 Typical Recharge Time Status Indicators Indicators LCD Audible Alarms Environment On Battery Low Battery Overload Operating Temperature 0 C to 40 C Communication PowerPanel Personal Edition Soft
5. nplug it from the AC power source before installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out CAUTION DO NOT USE WITH LASER PRINTERS The power demands of laser printers are too large for a UPS INSTALLING YOUR UPS SYSTEM UNPACKING The box should contain the following 1 UPS Unit x 1 2 User Manual x 1 3 USB cable x 1 4 Management software Disk x 1 OVERVIEW The DL450ELCD DL650ELCD DL850ELCD ensures consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Make sure that the total Volt Amp VA requirements of your computer monitor and peripheral equipment does not exceed 450VA 650VA 850VA 3 Ensure that the equipment plugged into the battery power supplied surge outlets does not exceed the UPS unit s rated capacity 450VA 270W for DL450ELCD 650VA 360W for DL650ELCD 850VA 490W for DL850ELCD If the rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at
6. ully charged Recharge the battery by leaving the UPS plugged in Contact CyberPower Systems about replacement batteries at www cpsww eu Circuit breaker has tripped due to an overload The UPS does not perform expected runtime Battery is slightly worn out The on off switch is designed to prevent damage by rapidly turning it off and on Contact CyberPower Systems about The battery is worn out replacement batteries at www cpsww eu Mechanical problem Contact CyberPower Systems at www cpsww eu Turn the UPS off Wait 10 seconds and then turn the UPS on The UPS will not turn on Additional troubleshooting information can be found at www cpsww eu For more information visit www cpsww eu or contact CyberPower Systems Inc All rights reserved Reproduction without permission is prohibited cE Z
7. ware Relative Humidity Windows 7 Vista XP 2000 Server 2003 Linux 0 to 90 Non condensing Management Auto Charger Yes Auto Restart Yes CYBERPOWER GREENPOWER UPS TECHNOLOGY CyberPower s Green Commitment CyberPower is dedicated to the development of green products and has adopted Green practices throughout its business including membership in Climate Savers Computing Initiative CSCI accordance with the Restriction on Hazardous Substances RoHS Waste Electrical and Electronic Equipment WEEE protocols as well as ISO 14001 and IECQ QC080000 CyberPower pledges to provide the advanced energy solution for the environment and become a leading eco friendly organization in the UPS industry ENERGY SAVING TEGHHOLGGT Reduce Energy Cost with GreenPower UPS Tech nology CyberPower s goal is not only to provide eco friendly products but also to bring the best value for consumers The advanced energy saving design improves the operating_efficiency and eliminates waste energy consumption As a result consumers will enjoy significant energy cost savings with the adoption of GreenPower ups technology TROUBLESHOOTING Problem Possible Cause The outlets stop providing power to equipment Circuit breaker button is projecting from the side of the unit Turn the UPS off and unplug at least one piece of equipment Reset the circuit breaker by depressing the button and then turn the UPS on Battery not f