1.     Setting the Display Contrast    1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni Butbonz  Buttons Button       Configuration button    2  Press the upper right button to display the display menu     Display menu    Clock DisFlay       3  Adjust the display contrast using the two upper buttons   Less contrast More contrast      Contrast      Back light LED       Next display menu    4  Press the configuration button repeatedly to quit the display menu     Remarks    e Hold the configuration button pressed for 8 seconds to display the contrast mode    e The display contrast may be set too low if experiencing a blank display  Hold the configuration button  pressed for 8 seconds to switch the module to the configuration menu which allows modifying contrast   Hold the upper right push button pressed for 3 seconds  The contrast will be set at its maximum    e The module will automatically quit the configuration mode after 30 seconds of inactivity     VMB4PD 9    Setting the Display and Push Button Backlight    The backlight intensity can be set according to your preferences  completely off  completely on or  dimmed   The module allows you to automatically modify the intensity twice a day    The push button backlight intensity can also be set according to your preferences  This is useful when  trying to locate the buttons in a completely dark room     1  Hold the configuration button pressed for 4 seconds to display the configu
2.    VMB4PD    Push Button and    Timer Module  for Velbus System       Push Button and Timer Module for velbus   system VMB4PD    Introduction    This unique panel will let you control all of the output modules on the Velbus   system  There is no need to  remember the function of each button  just read the label next to it    The module also features programmable timing functions to automate daily or weekly button press actions   The infrared receiver will let you control the module at distance     Features   Four push buttons and one configuration push button    Up to 8 commands  2 groups of 4 commands each     The 2 command groups are directly callable through the configuration push button   Automatic switchover to the first group of commands after 15 seconds of inactivity   Push button debounce  65ms    Possibility for each push button to react only when maintaining pressed  1s  2s of 3s    Adjustable push button backlight  off     low dimming     high dimming     max  intensity   LED indication for each push button  slow  fast  very fast blinking or continuously on     Remote Control    Built in IR receiver for use with the Velbus     Can be used with the VMBIRTS IR remote stick  IR modulation  RECS80   Transmitter receiver range   10m    LCD display    2 lines of 16 characters   White backlight   Adjustable backlight  off     low dimming     high dimming     max  intensity   Possibility to automatically adjust the backlight intensity  twice a day    Adjustable contrast th
3.   5   amp    amp           34       MODULES       Velleman   is a major distributor of electronic products EZ        and components and has its own R  amp  D department   Velleman   is market leader in electronic kits with  offices all over the world                          In house training  amp  demonstration facility     www velbus be    Copyright 2007  Velleman NV  All rights reserved  Misprints reserved  All texts and images in this publication are protected by  copvriaht and other intellectual property riahts and mav not be copied for commercial ends or distribution and not be published        
4.   Back up battery power consumption  15mA    Battery not included     Dimensions    Push button module  L x W x H   66 x 44 x 30 mm   Push button module with frame  L x W x H   118 x 80 x 30 mm  Frame not included     VELBUS    2 wire communication for VELBUS data and 2 wires for power  Data transfer  16 6kbit s   Serial data protocol  CAN  Controller Area Network   Short circuit proof  towards negative or positive of power    Bus error indication  2 x short flash of the indication LED   Self restoring after 25 seconds in case of a bus error    Possibility to assign a name  max  15 characters  and a reaction time  65ms  1s  2s of 3s  which can be  saved in the non volatile memory    The command labels are displayed on the LCD  These labels consist of 2 lines of 16 characters each and  will also be saved in the non volatile memory    When pressing  maintaining pressed and releasing a push button  an instruction is being sent   Instructions will be accepted when setting the backlight  switching the indication LEDs on and off  slow   fast or very fast blinking of the indication LEDs  calling up the module type  the push button names and  when reading from or writing to the non volatile memory    The module can respond with the module type  the push button name or the contents from the memory     VMB4PD    Connection    For connection between the modules  use twisted pair cable  ex  EIB 2x2x0 8mm7  UTP 8x0 51lmm   CAT5  or other   Use minimum 0 5mm  cable  For long wiring   gt 50
5.   e Ster   l         Next program step setting    14  Press the lower buttons to add or to remove the displayed command to or from the program step     Label command 6       Add or remove command 5 Add or remove command 6    Next program step setting    15  Press the configuration button to display the next program step setting menu     Button5S Buttons  a Ster 1         Next program step setting    16  Press the lower buttons to add or to remove the displayed command to or from the program step     Label command 7 Button  Button   Label command 8    Ster Al         Add or remove command 7 Add or remove command 8    Return to general display    VMB4PD 25    17  Press the configuration button to return to the general display    Button  Button    Ster Al a       Return to general display    18  Press the lower buttons to add or to remove the displayed command to or from the program step     Next program step       Previous program step    Quit program menu    Let   s explain the example above     Command 1 will be executed every Monday morning at 08h30  commands 3  5 and 8 will be  activated briefly     Program indications for commands 1 through 4 disappear if the timer function has been  activated for the second set of commands only  Timer mode  4CH      Remark   e The module will automatically quit the program menu after 30 seconds of inactivity     VMB4PD 26    Activating and Deactivating the Timer per Command    The program will only be executed if the timer function for th
6.  after 30 seconds of inactivity     VMB4PD 13    Activating the Main Clock    All modules  with clock function  connected onto the Velbus   system must adopt the same time in order  to work properly    This can be achieved by setting the main clock o none of the connected modules  This module will send  the time over the Velbus   system once every day and synchronize all other clocks     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni Button  Buttons Buttont       Configuration button    2  Press the upper left button to display the clock menu   Clock menu    Clock DisrFlay       3  Press the configuration button again to display the next clock menu     Store Das  Mo  Hour  B Mineo       Next clock menu    4  Press the upper right button to  de activate the main clock   The lower line shows the software version     Main clock on off    Master clock   OFF  Build 8735       Quit clock menu    5  Press the configuration button to quit the clock menu     Remarks   e Activate the main clock o none module only   e The module will automatically quit the configuration mode after 30 seconds of inactivity     VMB4PD 14    Addressing    Every module connected onto the Velbus   system must have a unique address which can be set via the  configuration menu    Make sure to synchronize the IR transmitter receiver by setting the correct address    The final digit represents the address to be entered into the IR transmitter  see manual for 
7.  onoff       Timer activation menu    The timer activation menu is possibly not available which means there is no command used in  the program  In this case  press the configuration button again to exit the menu    Go to section 10 the timer function is activated for the second set of commands only  Timer  mode  4CH     Go to section 8 if commands 1 and 2 are not used in the program    Go to section 10 if commands 1 through 4 are not used in the program    Go to section 12 if commands 1 through 6 are not used in the program     6  Press the lower buttons to activate or deactivate for the displayed commands   The timer indication means         the command will not be used in the timer program and cannot be modified             the timer program for a particular command will not be executed      3      the timer program for a particular command is activated     Label command 1 Buttoni  Buttonz Label command 2      ter on off       Activate deactivate timer Activate deactivate timer  program command 1 program command 2    Next timer activation menu    VMB4PD 28    7  Press the configuration button to enter the next timer activation menu     Buttonl Buttonz     amp  tee on off       Next timer activation menu    The module exits the timer activation menu if commands 3 through 8 are not used in the  program  go to section 14     Go to section 10 if commands 3 and 4 are not used in the program    Go to section 12 if commands 3 through 6 are not used in the program     8  Press the 
8. B4PD    17    Setting the Reaction Time    All commands have a short reaction time  65ms  by default  This reaction time can be set at 1  2 or 3  seconds     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni Button2  Buttons Buttong       Configuration button    2  Press the configuration button again to display the next configuration menu     Clock Diseley       Next configuration menu    3  Press the lower left push button to display the reaction time menu     Moe Address  Regction Labels       Setting reaction  time i    Quit configuration menu    4  Press the lower buttons to set a reaction time of 0  1  2 or 3 seconds for the displayed command   Press the configuration button to display the next configuration menu     Label command 1 Buttoni itt Label command 2    Bs Reaction Bs       Modify reaction time command 1 Modify reaction time command 2    Next reaction time menu    VMB4PD 18    5  Press the lower buttons to set a reaction time of 0  1  2 or 3 seconds for the displayed command   Press the configuration button to display the next configuration menu     Label command 3 Buttons Buttont Label command 4    s Feaction   s       Modify reaction time command 3 Modify reaction time command 4    Next reaction time menu    6  Press the lower buttons to set a reaction time of 0  1  2 or 3 seconds for the displayed command   Press the configuration button to display the next configuration menu     Label command 5 Buttona But
9. MBIRTS manual      Activating commands 1 through 4 on the stick will make the module display the corresponding labels     Buttoni Button     Bubtons Bubtond       Activating commands 5 through 8 on the stick will make the module display the corresponding labels     Buttons Burt ton    Button  Buttons       The module will automatically return to the default set of commands after 15 seconds of inactivity     Remark     e The module will not switch to the corresponding labels if the current is displayed     e Make sure to synchronize the IR transmitter receiver by setting the correct address  Refer to     Addressing    and the transmitter user manual     VMB4PD 32    Troubleshooting    No display    e The display contrast is too low  Hold the configuration button pressed for 3 seconds to switch the  module to the configuration menu which allows modifying contrast  Hold the upper right push button  pressed for 8 seconds  The contrast will be set at its maximum    e Selection of blank characters during labelling  Press the configuration button a couple of times until a  blinking cursor is displayed in the upper left corner  Enter your label using the 4 push buttons       Remove the power supply during min  10 seconds    The remote control stick does not function    e Drained batteries in the transmitter  Replace the batteries    e Addresses of the transmitter receiver are not synchronized  See    Addressing    and the transmitter    s  notice     VMB4PD 33    VMB4PD    v     a  2
10. ally quit the display menu after 30 seconds of inactivity     VMB4PD 11    Setting the Clock    You only need to set the clock from one module  All other modules connected in the system will adopt  the set time     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni Buttonz  Buttons Buttond       Configuration button    2  Press the upper left button to display the clock menu     Setting the clock    Clack Display       3  Press the upper right button to set the day     Setting the day    Store Dos  Mo  Hour    Min  ee       4  Press the lower left button to set the hour     Store Das  Mo    Hour     Mirntee       Setting the hour    5  Press the lower right button to set the minutes     VMB4PD 12    Store Das  Mo    Hour    Mint ae       Setting the minutes    6  Confirm by pressing the upper left button     Confirm time    Store Derg  Mo    Hour    Min        Next clock menu    Remarks    The seconds counter starts from 0 when setting the time  Wait for the beginning of a minute   e Hold the configuration button pressed for 8 seconds to display the contrast mode    e The display contrast may be set too low if experiencing a blank display  Hold the configuration button  pressed for 8 seconds to switch the module to the configuration menu which allows modifying contrast   Hold the upper right push button pressed for 3 seconds  The contrast will be set at its maximum    e The module will automatically quit the configuration mode
11. cation LED command 2          Command 1 Command 2  Label command 1 Buttoni Buttons Label command 2  Label command 3 Buttons Buttont Label command 4  Command 3 Command 4  Indication LED command 3 Indication LED command 4  Configuration push button  Push the configuration button to switch to the next four commands   Indication LED command 5 Indication LED command 6  Command 5 Command 6  Label command 5 BULL Bubini Label command 6  Label command 7 Button  Label command 8  Command 7 Command 8  Indication LED command 7 Indication LED command 8    Configuration push button    The module switches back to the default command display after 15 seconds of inactivity   You can switch between the two displays at any time by pressing the configuration button     When pressing  maintaining pressed and releasing a push button  an instruction is being sent on the  Velbus    These messages identify which push button has been pressed  maintained pressed or released   Other modules  relay modules  blind control modules  dimmers     connected to the Velbus   will react and  answer by resending a command message to the push button module  This command will switch off  light  of blink the indication LEDs    How a specific push button will control a particular module is explained in the learning mode of the  concerning modules     VMB4PD 6    Configuration    When using the module in the Velbus   system for the first time  configure   e contrast  e backlight  e push button backlight  e clock  e addr
12. e command is activated   Deactivate the timer for the commands you do not want to be executed during a certain period  e g     during v    1     2     VMB4PD    acation period      Press the configuration button to display the second set of commands     Buttoni Buttonz    Buttons Buttont       Configuration button    Press the configuration button to display the clock     Buttons Buttont  Button  Buttona       Configuration button    The module displays the current time and an overview of the active timer programs   The timer indication means         the command will not be used in the timer program             the timer program for a particular command will not be executed      3      the timer program for a particular command is activated   The timer indications for commands   through 4 disappear if the timer function has been  activated for the second set of commands only  Timer mode  4CH          Timer indication command 2    Timer indication command 6  Timer indication command 8    Timer indication command 5  Timer indication command 1  Timer indication command 3    Timer indication command 7 Timer indication command 4    Configuration button    In the example above   Commands 1  3  5 and 8 will be used in the program but the program will not be executed     27    4  Hold the configuration button pressed for 4 seconds to display the configuration menu        Configuration button    5  Press the lower right button to enter the timer activation menu     Clock Disrley  Prod
13. ess  labels  reaction time  mode  timer    Call the configuration menu by holding the configuration pressed for 4 seconds     Buttoni  But tonz  Buttons Buttont       Configuration button    The configuration menu will be displayed   Clock menu Display menu    Clock Disrlos       Next configuration menu    Press the upper left push button to activate the clock menu   Press the upper right push button to activate the display menu   Press the configuration button to display the next configuration menu     Mode menu Address menu    Mode Address     Reaction Labels       Reaction time Label  menu editor  Quit configuration menu    Press the upper left push button to activate the mode menu   Press the upper right push button to activate the address menu   Press the lower left push button to activate the reaction time menu   Press the lower right push button to activate the label editor    Press the configuration push button to quit the configuration menu     VMB4PD    Remarks   e In configuration mode pressing the push buttons will no more be sent through the Velbus     e All settings will be saved in the module  even with a power failure    e The first configuration menu shows menus    Prog    and    Timer on off    when the timer is activated   e The module will automatically quit the configuration mode after 30 seconds of inactivity   e Hold the configuration button pressed for 8 seconds to display the configuration menu which allows  modifying contrast and backlight     VMB4PD
14. iguration button    The module will automatically switch to the default command set after 15 seconds of inactivity   Press the configuration button again to return to the default command set  if the timer is deactivated  or to  the display the current timer  if the timer is activated      Indication LED command 1 Indication LED command 2    Command 1 Command 2    Timer indication command 5 Timer indication command 5    Timer indication command 6  Timer indication command 8    Timer indication command 1  Timer indication command 3    Timer indication command 4  Command 4    Timer indication command 7  Command 3       Indication LED command 3 Indication LED command 4    Configuration button    The push buttons and their indication LED are configured in the first set of commands   The timer indication means      o     the command will not be used in the timer program             the timer program for a particular command will not be executed      3      the timer program for a particular command is activated   Timer indicators for commands   through 4 disappear if the timer function is activated for the seconds set  of commands only  Timer mode  4CH    It is possible to switch between the different displays by pressing the configuration button     VMB4PD 31    Using the VMBIRTS IR Remote Stick    All 8 commands can directly be activated using the IR remote stick     Point the IR remote stick towards the push button module and activate the desired channel on the stick   see the V
15. l only     4CH     control panel with timer function for the second set of commands  commands 5    8        8CH     bedieningspaneel met schakelklokfunctie op alle bedieningen    Modify mode settings      Timer mode  OFF       Quit mode menu  5  Press the configuration button to quit the mode menu     Remark   e The module will automatically quit the mode menu after 30 seconds of inactivity     VMB4PD 20    Programming the Timer    Programming can only be done if the timer function was selected in the user mode    The commands can be automated via the timer function  It is like you would activate a command at a  particular time of the day  Twenty program steps can be programmed  each step has a programmable time   day  hour and minutes  and command     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni Buttons    Buttons Buttong       Configuration button    2  Press the lower left button to display the program menu     Clock Diseloay  Prog       Program menu    3  The display shows the first program step  program number  time and a view of the automated          commands         Hever   l      a       H   ee  Day  Program number  Program indication command 5 Program indication command 2  Program indication command 1 Program indication command 6  Program indication command 3 Program indication command 8  Program indication command 7 Program indication command 4  Program time  Remark     The program indications for commands 1 t
16. lower buttons to activate or deactivate for the displayed commands     Label command 3 Buttona Buttont Label command 4    ter onoff       Activate deactivate timer Activate deactivate timer  program command 3 program command 4    Next timer activation menu    9  Press the configuration button to enter the next timer activation menu     Buttons Buttont  E ter onoff       Next timer activation menu    The module exits the timer activation menu if commands 5 through 8 are not used in the  program  go to section 14    Go to section 12 if commands 5 and 6 are not used in the program     10  Press the lower buttons to activate or deactivate for the displayed commands     Label command 5 Buttons Button   Label command 6    ter on off       Activate deactivate timer Activate deactivate timer  program command 5 program command 6    Next timer activation menu    VMB4PD 29    11  Press the configuration button to enter the next timer activation menu     Buttons Bub tond   amp  ter on off       Next timer activation menu    The module exits the timer activation menu if commands 7 and 8 are not used in the program   go to section 14      12  Press the lower buttons to activate or deactivate for the displayed commands     Label command 7 Button  Buttons Label command 8  ter onoff           Activate deactivate timer Activate deactivate timer  program command 7 program command 8  Quit timer activation menu    13  Press the configuration button to quit the timer activation menu     Button  Bu
17. m  or if a lot of modules    gt  10  are connected  to one wire  use Imm  cable  Connect the 12 18Vdc  mind the polarity  and connect the bus wires  mind the  polarity          12V  BUS    TWISTED  PAIR     0 5mm      Connect a 9V battery  via the included cable  if you desire to power the clock in case of a power failure     Velbus    12V power supply          Hint  for advanced level only   Solder island    J    when using a back up battery in order to feed the battery     Velbus    12V power supply          Rechargeable    9V backup  battery       WARNING  NEVER use a regular battery  non rechargeable  when soldering island    J    to avoid  risks of explosion     VMB4PD 4    Termination     Velbus   Velbus    transmission LED reception LED  Termination  Velbus  9V back up  12V power battery    supply       Velbus   power LED    If the module is connected at the start or end of a cable on the VELBUS  place the    TERM    jumper     6     S5 xe    Remove the jumper in all other cases           lt LL    If different cable wiring topologies  tree  star  loop       are used  place a jumper on the end module of the  longest cable only  NOT on each end point     VMB4PD 5    Use    The module consists of 4 push buttons with corresponding LED indication and one configuration push  button  The label for each push button is displayed on the LCD    This module allows defining up to 8 commands    The module will display the first 4 commands by default     Indication LED command 1 Indi
18. o 4 disappear when the timer function has been  activated only for the second set of commands  Timer mode  4CH      VMB4PD 21    4  Press the upper right button to display the next program step     Next program step         Hever   l        a  BBA     y       Quit program menu    5  Press the lower right button to display the previous program step            Hever Ae      a   HIB sy       Previous program step    Quit program menu    6  Press the lower left button to modify the displayed program step     Next program step         Hever 41        41      BIG ee       Modify program step Previous program step    Quit program menu    VMB4PD 22    7  Press the upper right button to modify the day of the program step   Day setting    Stepi Dot Hever    Hour  A Mint se       Next program step setting    You can choose from the following                          Mo Program step is executed every Monday  Tu Program step is executed every Tuesday  We Program step is executed every Wednesday  Th Program step is executed every Thursday  Fr Program step is executed every Friday   Sa Program step is executed every Saturday  Su Program step is executed every Sunday       Sa amp Su   Program step is executed every Saturday and Sunday       Mo Fr   Program step is executed every day except on Saturday and Sunday       Mo Sa   Program step is executed every day except on Sunday       Mo Su   Program step is executed every day             Never   Program step will not be executed          8  P
19. ration menu     Buttoni Button     Buttons Button       Configuration button    2  Press the upper right button to display the display menu   Display menu    Clock Disrlay    3  Press the lower buttons to adjust the backlight intensity          Contrast      Back light LED       Display backlight Push button backlight    4  Press the configuration button to display the next display button       Contrast      Backlight LED       Next display menu    5  Press the upper right button to  de activate the backlight     VMB4PD 10    Backlight timer on off    Backlit tme  OFF       Quit display menu    6  Press the configuration button to quit the display menu if the backlight timer has been  deactivated     7  Activate the backlight timer using the upper right button when you desire to automatically    switch the backlight between two intensities   Backlight timer on off    Backlit tart OM       8  Press the configuration button to display the configuration menu for the backlight timer     Backlit tee  OH       Backlight timer configuration menu    9  Enter the first time and intensity using the upper buttons   Enter the second time and intensity using the lower buttons     Time Backlight intensity    8 68 Bcklit ON  26  88 Beklit LOW       Time Backlight intensity    Quit display menu    In the example above  the backlight will be set at full intensity at 08h00 and dimmed at 20h00   10  Press the configuration button to quit the display menu     Remark   e The module will automatic
20. ress the lower buttons to enter the time the program step must be executed        Setting the hour Setting the minutes  Next program step setting    9  Press the configuration button to display the next program step setting menu     Steri Baw  Mo    Hour   amp    in        Next program step setting    Go to section 14 if the timer function has only been activated for the second set of commands   Timer mode  4CH      VMB4PD 23    10  Press the lower buttons to add or to remove the displayed command to or from the program step     Label command 1 Buttoni Button  Label command 2    Ster   l         Add or remove command 1 Add or remove command 2    Next program step setting    Following symbols can be displayed          The command has not been accepted in the program step       The command has been accepted in the program step  The push button will be  activated automatically on the time  day  hour  minutes  programmed and  memorized into the program step                 11  Press the configuration button to display the next program step setting menu     Buttoni Button  G     ter Ai         Next program step setting    12  Press the lower buttons to add or to remove the displayed command to or from the program step     Label command 3 Buttons  Buttornd Label command 4    Ster Bi         Add or remove command 3 Add or remove command 4    Next program step setting    VMB4PD 24    13  Press the configuration button to display the next program step setting menu     Buttons Buttoned
21. rough configuration menu    Labelling on the display for each command  2 lines of 16 characters for each label    Configuration    Adjustable display contrast and backlight    Adjustable push button backlight    Adjustable command reaction time  at once  1  2 or 3 seconds    Command labelling    Module address configuration  256 possible addresses     Clock configuration    Mode configuration  command panel only  command panel with timer or command panel with timer for the  2  group of commands     Input and modification of the timer program steps    Timer activation or deactivation for a specific push button    Configuration menu will automatically close after 25 seconds of inactivity     Clock    Built in clock with day display    Setting one clock will adjust all other clocks on the Velbus   system    Possibility to configure one clock as main clock     all other clocks will run right     Timer    Programmable timer functions for push button command automation   Up to 20 program steps    Each program step can automate up to 8 commands     VMB4PD 2    Power Supply    Required power voltage  12 to 18VDC    Consumption  backlight off  13mA LEDs off   15mA LEDs on  backlight lowly dimmed  14mA LEDs off   16mA LEDs on  backlight highly dimmed  18mA LEDs off   19mA LEDs on  backlight max  intensity  26mA LEDs off  27mA LEDs on   Max  consumption  all LEDs activated and backlight max  intensity   27mA    Power supply LED indication    9V battery connection  clock back up power   
22. the VMBIRTS  transmitter     Example  push button model address   26  IR transmitter address must be 6     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Button  Buttonz    Buttons Buttond       Configuration button    2  Press the configuration button again to display the configuration menu     Clock Diseloy       Next configuration menu    3  Press the upper right button to display the address menu   Addressing       Mode Address    Reaction Labels    Quit configuration menu    4  Press the upper left button to select the left address digit  blinking digit    Press the upper right button to select the right address digit  blinking digit    Hold the lower left button pressed and press the lower right button to modify the selected    address digit  Select an address between    00    and    FE      Left address digit Left address digit        gt     Address  ga       Modifying address Modifying address digit    Quit address menu    5  Press the configuration button to quit the address menu     Remarks   e Make sure every module has a unique address   e The module will automatically quit the configuration mode after 30 seconds of inactivity     VMB4PD 15    Modifying the Labels  It is possible to label all commands so as to explain their function     1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Buttoni  Button2  Buttons Bubtond       Configuration button    2  Press the configuration b
23. ton Label command 6  Bs Reaction fs       Modify reaction time command 5 Modify reaction time command 6    Next reaction time menu    7  Press the lower buttons to set a reaction time of 0  1  2 or 3 seconds for the displayed command     Label command 7 Button  Buttons Label command 8  Bs Reaction Gs       Modify reaction time command 7 Modify reaction time command 8    Quit reaction time menu    8  Press the configuration button to quit the reaction time menu     Remarks   e The module will automatically quit the reaction time menu after 30 seconds of inactivity     VMB4PD 19    Setting the User Mode    The module can be used as a control panel or as a control panel with timer   The commands can be automated if the timer function has been activated  It is like you would activate a    command at a particular time of the day   The timer function can be applied to all commands  Timer mode 8CH  or to the second set of commands    only  Timer mode 4CH      1  Hold the configuration button pressed for 4 seconds to display the configuration menu     Button  Buttonz    Buttons Buttond       Configuration button    2  Press the configuration button again to display the configuration menu     Clock Diseloy       Next configuration menu    3  Press the upper left button to display the mode menu     Modemenu    Mode Address  Reaction Labels       Quit configuration menu    4  Press the upper right button to set the user mode   Following user modes are available      OFF     control pane
24. tton  tre ooff iz       Quit timer activation menu    14  The module displays the current time and an overview of the active timer programs  in this  example the timer program for commands 1  3  5 and 8 will be executed    Press the configuration button to display the labels or the clock     Z Z Monday    X 5 16       Configuration button    Remark   The module will automatically quit the timer activation menu after 30 seconds of inactivity     VMB4PD 30    Use    The timer function is deactivated by default and can be activated via the configuration menu  see section     Setting the User Mode         The module consists of 4 push buttons with corresponding LED indication and one configuration push  button  The label for each push button is displayed on the LCD    This module allows defining up to 8 commands    The module will display the first 4 commands by default     Indication LED command 1 Indication LED command 2    Command 1 Command 2  Label command 1 Button  Buttonz Label command 2  Label command 3 Buttons Buttond Label command 4  Command 3 Command 4       Indication LED command 3 Indication LED command 4    Configuration button    Press the configuration button to switch to the next set of commands     Indication LED command 5 Indication LED command 6        Command 5 Command 6    Label command 6  Label command 8    Label command 5  Label command 7    Buttons Button    Button  Buttona    Command 7 Command 8    Indication LED command 7 Indication LED command 8    Conf
25. utton again to display the configuration menu     Clock Bisrlas       Next configuration menu    3  Press the lower right button to display the label editor     Mode Address   Reaction Labels       Label editor  Quit configuration menu  4  Move the cursor to the left or to the right using the two upper push buttons     Select the character using the two lower push buttons   Press the configuration button to display the second set of commands  commands 5 to 8      Cursor to the left Cursor to the right    Button  Button     Buttons Buttont       Select character Select character    Display second set of commands    VMB4PD 16    5  Move the cursor to the left or to the right using the two upper push buttons     Select the character using the two lower push buttons     Cursor to the left Cursor to the right    Buttons Button      Button  Button       Select character Select character    Quit label editor    6  Press the configuration button to quit the label editor                                                     Remarks   e Following characters can be chosen from   0   P   p    1 A Q a q     i 2 B R b T    3 C S c s    4 D T d t    5 E U e u   amp  6 F V f v  i 7 G W g Ww    8 H X h X    9 I Y i y      J Z j Z      K   k    A  lt  L    l        M   m       gt  N a n      O   o                            e Hold a button pressed to scroll   e Scrolling will stop with a space character   e The module will automatically quit the label editor after 30 seconds of inactivity     VM
    