Home

6-inch IP Speed Dome User`s Manual

image

Contents

1. 24 I FUNCTION cuan ru 25 FACTORY DEFAULT SETUP V Ova ug 28 95 SD CARD FAQ 32 10 APPENDIX I DAILY MAINTENANCE AND IP SPEED DOME FAQ 33 101 Daily Maintenant 33 10 2 Jom S 33 11 APPENDIX Il THUNDER PROOF AND SURGE 34 3 12 APPENDIX HW ABOUT RS485 BUS cin rh na rr n 35 12 4 5485 Bus Main 35 12 2 RS485 Bus Transmission Distance eere ee eerte ee eee esteso tn tasse tatu sae ta than essen sene te tasse tata senses en 35 12 3 Connection Methods and Terminal Resistance eere eite teet ee teen en enata tatnen onn onte totos tano 35 12 4 Problem in Practical Use e eere eese esee tenete eese seta suse ta sene ios 36 12 5 RS4B5 BUS FAQ C 37 Welcome Thank you for purchasing our product This user s manual is designed to be a reference tool for the operation of your system Here you can find information about this IP speed dome features and
2. 8 1 2 19 Idle Status Hates State Sie aA nm Be thi ose A t dv S 9 1 2 20 Image Rotate a eieai eta ee aie a A 9 2 PROTOCOL BAUD RATE ADDRESS 10 2 1 Protocol and Baud Rate 10 2 2 Setaddress dial SWItCH 11 3 12 3 1 85485 and Power Cable Connection eerie eee esee ee reete eee ee teta enne n tne ta tasa enata 12 3 2 Alarm GCable Gonn ctliOn aE aa oee A O EEOSE EOE EOSS easi 13 RED PER T T m 14 3 2 2 Alarm Connectlon aneia erede e d 15 3 2 3 gt Keyboard Comece eraa EE 16 4 QUICK CONFIGURATION Tr kan anna nnmnnn 18 4 1 18 4 2 Ble rbe 18 5 WEB OPERATION cec excucucs excu cu eo aka Cu gU GE Cu Cu Fe au ka Cu 21 5 1 21 21 6 PERFORMANCE
3. Add terminal matching resistance smooth The distance between host and e Add RS485 distributor speed dome is too far Parallel connected too much speed domes Note This manual is for reference only Slight difference may be found in the user interface All the designs and software here are subject to change without prior written notice Please visit our website or contact your local retailer for more information 37
4. 202 101 172 35 3l 9 50 SD card hot swap Before draw out SD card please stop record or snapshot first and then wait for at least 15 seconds to remove the SD card All the operations before is to maintain data integrity SD card write Do not set the SD card as the storage media to storage the times schedule record file It may damage the SD card duration can not use the When disk information is shown as hibernation or capacity is 0 disk as the storage please format it first Via Web media can not upgrade the device network The status indication light is shown as red when network upgrade operation failed You can use port 3800 to continue upgrade Recommended SD Kingston Kingston 1GB Kingston 16GB Transcend card brand 16GB SanDisk 1G SanDisk 4G Usually we recommend the 4GB or higher high speed card in case the slow speed results in data loss 10 Appendix Daily Maintenance and IP Speed Dome FAQ 10 1 Daily Maintenance Please clean dome cover regularly to get vivid image Handle the cover with care Use water to wash Don t use cloth to clean Use mild detergent to clean if there is too much dust Note The sweat from your hand may erode plating surface your nail may scrape dome cover result in blur image 10 2 FAQ SYMPTOM CAUSE SOLUTION No self diagnosis no video signal when connect dome to power No self diagnosis There is a
5. 52 54 4 90 54 10 7 8 21 255 255 0 0 52 54 4 4 58 4 10 T 10 104 255 255 0 0 LTD 52 54 4c d 58 51 10 7 2 2 255 255 0 0 71 0 00 05 23 16 24 48 10 7 1 113 255 255 0 0 T 0 52 54 4c 3T 10 7 10 91 255 255 0 0 a 192 168 0 108 255 255 0 0 n Device Web 10 7 2 61 255 255 0 0 Ug Tip You can click login button directly and then input corresponding information to login Refresh R Login L Logout Figure 4 2 Select the Open Device Web item you can go to the corresponding web login interface See Figure 4 3 WtBservice e http 10 10 3 16 wx Ld ud We Bwewservice m mh G Toots Done 8 internet 100 Figure 4 3 If you want to modify the device IP address without logging in the device web interface you can go to the configuration tool main interface to set In the configuration tool search interface Figure 4 1 please select a device IP address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 4 4 In Figure 4 4 you can view device IP address user name password and port Please modify the corresponding information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you can not l
6. the IP speed dome can alert you according to your setup either pop up prompt or alarm System can activate corresponding channel to record video or snapshot The alarm information will be saved in the SD card or be sent to you via email 1 2 12 Auto Flip This function allows you to trace the object manually As long as you continue to hold the keyboard joystick in the down position the dome rotates 180 degrees and repositions itself for uninterrupted viewing of any subjects that passes directly beneath the dome 1 2 13 Self diagnosis There is a self diagnosis procedure when IP dome boots up and vertical engine check Camera diagnostics mainly the zoom function diagnostics Display IP dome information and diagnosis information such as address protocol baud rate IP speed dome model and its self diagnosis information and etc 1 2 14 Day Night Mode B W amp Color Mode Auto manual switches in low illumination Auto camera will automatically adjust CCD light level Manual use menu or function keys to select day night mode 1 2 15 Auto Focus Auto focus allows the lens to remain in focus during zoom in zoom out and motion functions to get vivid image You can use FAR or NEAR button to adjust focus manually 1 2 16 Backlight Compensation Balance the brightest and darkest sections of a scene to produce a more vivid picture 1 2 17 Pan Tilt and Zoom Supports zoom in and zoom out during tilt and pan movement In th
7. OSD transparent 128 Record Setup Channel Ch01 Pre record 5 seconds Period Setup Start time 0 00 00 End time 23 59 59 Record Period 1 Enable motion detection alarm Snapshot Period 1 Enable motion 28 detection alarm Week Sunday COM Setup Option COMO01 Function General Data bit 8 Stop bit 1 Baud rate 115200 Parity None Network Setup Ethernet Port 01 DHCP Disable IP address 192 168 1 108 Subnet mask 255 255 0 0 Gateway 192 168 0 1 Device name Device factory default name TCP port 37777 80 UDP port 37776 Network user connection amount 10 Network transmission QoS Disable Remote host Multiple broadcast group Enable Disable IP address 239 255 42 42 Port 36666 Email setup Enable Multiple DDNs Disable NAS setup Disable NTP setup Disable Alarm server Disable Alarm Setup Event type Local Alarm input Input 01 disable Type Normal open Setup Period Start time 0 00 00 End time 23 59 59 Period 1 enable Week Sunday Anti dither 0 second General output Disable Alarm latch 10 seconds Record channel 1 enable Record latch 10 seconds Send email Enable PTZ activation Disable Event type never Address 0 Snapshoot Disable Video Detection Event type Motion detection Channel Ch01 Disable Sensitivity 3 Time period setup Period Start time 0 00 00 End time 23 59 59 Perio
8. noise Red LED is not on 24V AC does not apply to the power Or connection is Check 24V AC power is connected or properly earthed too loose Check power supply condition Power off or Transformer or check 24V transformer problem Red LED light is on 24V AC power is low Something wrong with power socket Power supply is inadequate Use multimeter to check dome load If it is lower than 24V AC then the IP speed dome can not work Please contact your local retailer to replace power socket Replace power socket Mechanical malfunction Need electrical engineer help Self diagnosis is ok No video signal Power connection is too loose Connect tightly Check the circuit connection Connect again Video switch connection is wrong or improper operation Please refer to user s manual for cable connection information Self diagnosis is OK but can not operate the dome Video signal loss occurs in high speed rotation Video signal is not successive Control circuit is not properly connected Check control cable connection Dome address protocol or baud Power supply is not sufficient Circuit connection is too loose Please refer to user s manual for rate setup is not right detailed setup information Replace power socket Connect tightly Video switch or power problem Need electrical engineer help Video is not cle
9. 4 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON ON 3 Cable Connection 3 1 RS485 and Power Cable Connection This series IP speed dome has video cable port RS485 control cable port audio cable port network port and power port These cables are used to transmit video output signal 5485 control signal audio input and output signal and connect to the network cable and power cable and etc Please connect the power cable to the power socket connect the RS485 control cable to the RS485 port and then connect the audio video cable to the IP speed dome audio video port respectively See Figure 3 1 and Figure 3 2 S 77 D A W o 9 Network Cable Network Port Figure 3 1 Figure 3 2 Name Function 485 A 485 A It is to control IP dome built in PTZ B 485 B It is to control IP dome built in PTZ GND Ground AUDIO OUT Audio output port GND Ground port IN Audio connection port 12 VIDEO Ground port OUT Video output port Power port connection interface is shown as in Figure 3 3 HHE Figure 3 3 Name Function AC24V 24V power port Connect to the power cable EARTH Ground port AC24V 24V power port Connect to power cable Extension RS 485 port is shown as in Figure 3 4 HHHH E Figure 3 4 Name Function 485 Extension peripheral 485 port Such as contr
10. 6 IP Speed Dome User s Manual 1 Table of Contents 1 FEATURE AND FUNG TION nnna 7 1 1 General idein rei tTo EIER 7 1 2 zb C 7 1 2 1 StOrage euo Seta o dem Oo eO derat to nO dO F 1 22 Network MONON rH re e e Ree Le 7 1 23 Dun serae notante stadia ean nebat tinm Ani en din eit rbi dis 7 1 2 4 Support multiple protocols 7 1 2 5 Proportional Pan and Tilt enne 7 1 2 6 Preset Setup and Recall sisse eene ener ethernet inneren nete nennen nnne 7 1 27 Auto S cani issue ERE cc a 7 1 2 8 Auto Cruise Touring ertt KER AEE 7 1 2 9 E 8 1 2 10 Privacy Masklng ioo etre e aire 8 1 2 11 xia ace en aa ee Aout alte hua eR T 8 1 2 12 ee eme bine tav etta 8 1 2 13 Selfsdiagnosisz RR rp Ret ee n 8 1 2 14 Day Night Mode B W amp Color Mode nennen enne nnne nennen 8 1 2 15 Auto FOCUS meatus RSS S ARDOREM ARI NUES 8 1 2 16 Backlight Compensation terret teneret e earn 8 1 2 17 m amabam ed eomm menu ae ERBEN 8 1 2 18 3D Intelligerit LOCATION ierit rete P iet tent e iden Pe
11. D for detailed information 23 6 Performance Specification Specification Index Standard PAL 251 5 Supported NTSC 30f s Encode capacity One D1 one CIF Video Encode bit stream D1 704 576 704 480 HD1 352 576 352 480 CIF 352 288 352 240 720 288 QCIF 176 144176 128 QVGA 320 240 QQVGA 160 128 Encode Speed NTSC 1f s 30f s for each channel Adjustable PAL 1f s 25f s for each channel Adjustable Network Max supports 10 users to view real time video via network Network output bandwidth gt 40Mbps Network input bandwidth gt 4Mbps Power Consumption 50W Power 24 Temperature 40 60 C Protection Level IP66 Working Environment Humidity Less than 90 Package Dimension 525mm 325mm 340mm Weight 5kg 24 7 Function Specification Specification Note Zoom Adjustment Manual Lens Control Focus Adjustment Auto Manual Aperture Adjustment Auto manual Preset 200 Auto Tour 8 Auto Pattern 5 Auto Scan 5 Auto adjusts the speed according Focus speed auto control t thefocus distance PTZ Control Tilt 90 degrees auto flip to realize Auto flip m 180 degrees continuing trace Auto rotation speed 0 1 300 s Preset max speed 300 Manual tilt flip speed 0 1 150 s RS485 PTZ control Baud rate 1200 2400 4800 9600 White balance adjustment Trace auto manual indoor
12. Medium to High Medium high Prompt A Appropriate for most websites M Rur Activex controls a Prompts before downloading potentially unsafe Run Actives controls and plug ins content OY annavad Unsigned Activex controls will not be downloaded lt Takes effect after you restart Internet Explorer Reset custom settings Reset to medium high default Reset all zones to default level Figure 5 2 After installation the interface is shown as below See Figure 5 3 Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login WEBservice Windows Internet Explorer E Jm r3 Qi NOE c rece WER servi ver dE i LLL LLL uud ll l ln l1 C 1100 Figure 5 3 After you logged in you can see the main window See Figure 5 4 There are six sections 22 Section 1 Monitor channel menu tree Section 2 System menu Section3 PTZ control Section4 Color setup and other setup Section5 Preview window Section 6 Monitor window switch WER serice SEARCH CONFIG LOGOUT Open All Refresh StartDialog Local Play Speed 1 8 5 Zoom Focus Figure 5 4 Please refer to 6 inch IP Speed Dome Web Operation Manual included in the resource C
13. Usually the return TTL value should be less than 255 Open IE and input device IP address in the address column For example if your device IP is 192 168 1 108 factory default IP address then please input http 192 168 1 108 in IE address column See Figure 5 1 lani Windows Internet Explorer input your IP amp address here f Blank Page _ g d amp Be i Page Internet 100 Figure 5 1 System pops up warning information to ask you whether install webrec cab control or not Please click yes button If you can t download the ActiveX file please modify your settings as follows See Figure 5 2 21 Internet Options 1 Security Settings Internet Zone General Security Privacy Content Connections Programs Advanced Settings O Disable Select a zone to view or change security settings O Enable 19 Download signed ActiveX controls not secure 4 E O Disable Internet Local intranet Trusted sites 9 Enable not secure E Prompt recommended Internet 19 Download unsigned ActiveX controls not secure Disable recommended 9 Enable not secure Prompt Security level For this zone uU Dou e not marked as safe for s Enable not secure Sites This zone is For Internet websites except those listed in trusted and restricted zones Allowed levels For this zone
14. ar Focus is in manual mode Control manually Dome cover is dirty Wash dome cover During camera switch there is a tilt movement in the monitor Camera power is not in the same Phase When several domes are connected to one transformer please connect the transformer output cable to the domes same side 33 11 Appendix Thunder Proof and Surge Protection This series speed dome adopts TVS lighting protection technology It can effectively prevent damages from various pulse signals below 1500W such as sudden lighting and surge While maintaining your local electrical safety code you still need to take necessary precaution measures when installing the speed dome in the outdoor environment The distance between the signal transmission cable and high voltage device or high voltage cable shall be at least 50 meters Outdoor cable layout shall go under the penthouse if possible For vast land please use sealing steel tube under the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to you
15. arm output Alarm 7 ch local alarm network alarm input Activate alarm via motion detection or external input Please enable pre record function when activating the alarm Upload JPEG file via email Send out alarm notice via email external port Need anti dither supported when alarm occurs frequently Support video short time buffer storage before or after alarm Pre record is 2Mbytes Buffer storage video of 5s RS485 PTZ control Support semi duplex communication way PTZ control via Web Network remote upgrade Working wit the upgrade Device Upgrade tool in the resource CD COM upgrade Working wit the upgrade tool in the resource CD Event Management Control Log in the client end software in Device Management the PC to monitor IPC IP speed dome provides user interface to modify device information video information record setup motion detection setup alarm setup OSD information IP speed dome provides user interface to search log status user management email setup time and date setup to check Parameter Configuration 26 system running information Log Important event log record It can record the following information System operation setup operation alarm event record management user management clear log Digital watermark Prevent from unauthorized data modification RESET Support hardware software Watchdog re
16. as strong electromagnetic interference There are too much devices connected to the RS485 bus And vice versa the max transmission distance shall become longer 12 3Connection Methods and Terminal Resistance RS485 bus requires all devices use the following connection methods Both terminals shall have 120 9 resistance See Figure 12 1 N 1H 2 31 i Figure 12 1 Or you can refer to for the simplified way as Figure 12 2 But the distance between D shall not exceed 7M 35 Control Device Figure 12 2 About device terminal 120 connection J2 1 2 2 3 1200 ON OFF There are 120 2 device terminal resistance in power socket There are two connection ways The first one is shown as in Figure 12 3 It is the factory default connection method Now the jumper caps connection board are connected to the second and third socket the 120 9 has not connected 1 2 3 Default jumper setup 1200 resistance has connected Figure 12 3 If you want to connect to the 1200 resistance you can remove the jumper caps from the second and the third socket and then insert them to the first and second socket respectively See Figure 12 4 Now you has connected to the 120 9 resistance E 2 28 Jumper setup Connect to 1200 resistance Figure 12 4 12 4 The Problem in Practical Use In practical usage we usually adop
17. d 1 enable Week Sunday 29 Anti dither 5 seconds General output Disable Alarm latch 10 seconds Record channel Disable Record latch 10 seconds Send email Disable PTZ activation Event type Never Address 0 Disable Snapshot Disable PTZ Setup Channel Ch01 Protocol DH SD1 Address 1 Baud rate 9600 Data bit 8 Stop bit 1 Parity None Default and Backup All Disable General Disable Encode Disable Record Disable COM Disable Network Disable Alarm Disable Video detection Disable Display output Disable Channel No Disable Advanced Event Type No disk disable Abnormity General Output t Disable Alarm Latch 10 seconds Send email Disable Record control Auto Ch1 User account admin password admin 888888 password 888888 reusable 666666 password 666666 reusable default password tluafed Snapshot Channel Ch01 Snapshot mode Scheduled Frame rate 1f s Resolution D1 Quality 6096 Auto maintain Auto reboot 02 00 everday Auto delete old Never files Camera Property Channel 1 Exposure mode N A Day night mode N A Backlight compensation N A White balance N A 30 Signal Type Internal input Mirror N A Flip N A Auto registration Enable Disable SN 1 IP 0 0 0 0 Port 7000 Device ID Dahua DNS Setup DNS 202 101 172 35 Alternative DNS
18. e Processor Keyboard Figure 3 12 17 4 Quick Configuration Tool 4 1 Overview Quick configuration tool can search current IP address modify IP address At the same time you can use it to upgrade the device Please note the tool only applies to the IP addresses in the same segment 4 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc ConfigTool Device List SN IP Address Subnet Mask Default Gat Mac Address 10 T 5 4T 255 255 0 0 10 T 0 52 54 4 90 5d 10 T 8 21 255 255 0 0 10 7 0 52 54 4c d 58 e4 10 7 10 104 10 7 0 4 58 51 10 7 2 2 255 255 0 0 10 7 0 00 05 23 16 24 48 10 7 1 113 3TTTT 255 255 0 0 10 7 0 52 54 4c 35 37 10 7 10 91 3TTTT 255 255 0 0 10 7 0 00 12 26 45 23 65 192 168 0 108 255 255 0 0 192 158 0 1 00 1 90 57 db 10 7 2 61 3TTTT 255 255 0 0 10 T 0 1 00 09 30 ad 00 12 1 1 1 1 1 1 1 2 3 4 5 5 T 8 Tip You can click login button directly and r then input corresponding information to login Refresh Login 1 Logout C Figure 4 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 ConfigTool Device List 10 T 6 4T 255 255 0 0 iTA
19. elow See Figure 2 1 s in 9 S j 4 4 6 2 N NNI e 5 J gt Lol OTS 5 Figure 2 1 Please refer to the protocol sheets for detailed information Please note this series IP speed dome can intelligently recognize the DH SD PELCO D PELCO P You do not need to set he protocol Protocol Baud rate Parity 1 2 3 4 5 6 7 8 1 2 3 4 Communication Protocol OFF OFF OFF OFF DH SD Compatible with China industrial standard protocol 10 PELCO D OFF ON OFF OFF PELCO P X X X X Reserved Please refer to the baud rate sheet for detailed information 5 6 Baud Rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Please refer to the parity setup sheet for detailed information 2 2 Set address dial switch The encode mode adopts binary system 1 to 8 is valid bit The highest address bit is 255 You can refer to the following sheet for more information 11 Address 1 2 3 4 5 6 7 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 25
20. functions Before installation and operation please read the following safeguard and warning carefully Important Safeguard and Warning 1 Electrical Safety All installation and operation should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation 2 Transportation Security No heavy stress violent vibration or water splash are allowed during transportation storage and installation This series product must use split type package during the transportation We are not liable for any damage or problem result from the integrated package during the transportation 3 Installation Keep upwards Handle with care Does not touch the lower dome cover it may affect the video quality Do not apply power to the dome before completing installation 4 Qualified Engineers Needed All installation here should be done by the qualified engineers All the examination and repair should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 6 Environment This product has been tested and found to comply with the IP67 standard of Degrees of protection provided by enclosure IP Code The dome should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc 7 About Camera Camera should be
21. installed away from direct sunlight or other strong artificial lights to avoid blooming and smear When the camera is aiming at bright light or object such as spotlight or sun smear or blooming may appear Only use mild detergent or dry cloth to clean the camera 8 About Accessories Always use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if something is missing in your package 1 Feature and Function 1 1 General Introduction This 6 inch IP dome integrates the remote network monitor function and integration high intelligent speed dome together It is easy to install and operate This series IP speed dome has vivid video and supports intelligent recognition privacy mask alarm activation wide dynamic region WDR function and etc It can guarantee the stability of audio video data and control data transmission via network technology so that this series product can realize real time monitor in anytime and at any where Working with the built in PTZ the 6 inch IP speed dome can implement the quick accurate and convenient positioning surveillance 1 2 Feature This series IP speed dome has the following features 1 2 4 Storage Support central server backup function in accordance with your configuration and setup to save audio video data Support record via Web the recorded fi
22. is period focus and iris are both in auto mode to get vivid video 1 2 18 3D Intelligent Location Working with DVR or WEB just click part of the current scene that zone will be displayed in the central window and automatically zooms All of these allow you to trace precisely 8 1 2 19 Idle Status When there is no available order you can use menu to set dome idle status after specified period The idle status includes turn to specified preset or go to scan cruise or pattern function You can set corresponding serial number for each actions 1 2 20 Image Rotate Via menu you can realize the image rotation function so that you can view the video more conveniently 2 Protocol Baud Rate Address setup Important Before you control the IP dome via RS485 you need to set baud rate and address manually Otherwise you can not control this series IP dome If you are going to use the Web to control the IP dome you do not need to implement the above setup Please refer to 6 inch IP Speed Dome Web Operation Manual chapter 3 2 8 included in the resources CD for detail information 2 1 Protocol and Baud Rate Setup Turn the IP dome transparent cover out you can see the dial switch button in the main board Please configure the following settings before begin controlling dome e Baud rate Address Note Each time you need to reboot the speed dome to get all the setups activated Open the lower dome the interface is shown as b
23. le are storage in the client end PC Support local SD card hot swap and memory backup function support short time backup when encounter network connection failure 1 2 2 Network Monitor Supports audio video data transmit to network terminal and then decode Audio and video transmission protocol HTTP TCP UDP MULTICAST and RTP RTCP and etc Support Web access Max supports 10 connections 1 2 3 OSD This series IP speed dome support on screen menu display and switch function in the Web It is easy for you to view dome information and configure dome camera parameters 1 2 4 Support multiple protocols This series speed dome supports and intelligently recognize universally used protocols PELCO P and PELCO D You can use various devices such as matrix control keyboard and DVR and protocols to control the IP speed dome 1 2 5 Proportional Pan and Tilt This function keeps the image from moving too fast when there is a large amount of zoom Speed dome continually decreases or increases pan and tilt speeds in proportion to depth of zoom When zooms speed is increasing the camera moving speed becomes slow When zooms speed is decreasing the camera moving speed becomes fast 1 2 6 Preset Setup and Recall Preset function is to save the address information such as PTZ pan tilt focus and etc to the memory so that you can quickly adjust the dome and PTZ to the correct position This series speed dome supports 200
24. ogin the device If you are use device background upgrade port 3800 to login other setups are all invalid Address 10 10 3 16 User Name Password eios Port arr Figure 4 4 After you logged in the configuration tool main interface is shown as below See Figure 4 5 19 ConfigTool NetWork Parameter General Parameter DHCP Enable PPPOE IP Address 10 10 3 16 System Information Subnet Mask 255 255 0 0 System Upgrade Gateway 10 10 0 1 Mac Address 52 54 4 43 64 Figure 4 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD 20 5 Web Operation 5 1 Overview IP speed dome support Web access via PC to manage device Web operation consists of the following operation sections monitor channel record search alarm setup system setup PTZ control and monitor window 5 2 Login Before web operation please check the following items and IP speed dome connection is OK You have set PC IP address IP speed dome IP address subnet mask and gateway Please set the IP address of the same section for the PC and IP speed dome Please input corresponding gateway and subnet mask if there are routers IP speed dome default IP address is 192 168 1 108 Use order ping IP speed dome IP address to check connection is OK or not
25. ol temperature humidity sensor 2 Extension peripheral 485 port Such as control temperature humidity sensor GND Ground port 12V External device power port Provide power to the eripheral equipment 3 2 Alarm Cable Connection Open the dome cover and take PTZ chip core out Turn the core upside down you can see the alarm port See Figure 3 5 i i Name Function Alarm out 1 2 Figure 3 5 e Two alarm output channels When there is an alarm from current 13 channel system activates relay or not e Alarm output relay default setup is NO You can use the jump cap near the power board relay to set e NO Normal open alarm output e NC Normal close alarm output GND Alarm input ground end Alarm in 1 7 e Seven alarm input channels They are to receive relay signal from the external alarm source You can go to dome menu to activate specified preset or patter e When the activation mode is NO normal open dome alarms when there is low voltage High voltage will not activate the alarm e When the activation mode is NC normal close dome alarms when there is high voltage Low voltage will not activate the alarm Note Dome alarm input message is ground mode Dome alarm input signal are two modes normal open and normal close 3 2 1 System Layout 3 2 1 1 BUS connection Please refer to the following interface fo
26. outdoor Backlight compensation control Manual Contrast ness adjustment Manual Video Process Gain Manual Electronic shutter control Auto Manual Color B amp W Day Night switch Auto Manual Schedule D1 HD1 BCIF CIF QCIF VGA Resolution QQVGA Max support D1 resolution Video compression H 264 Support motion detection zone Motion Detection setup Support one main stream and one Dual stream extra stream Bidirectional Talk Delaying value Audio within 200ms Audio Listening Support 1 ch MIC input WEB Access PPPoE DHCP DDNS is SMTP Support IP address auto search function Support IP address filter function Record Schedule Record 6 periods in one day Manual Record After enabling manual record no 25 matter system is in schedule or alarm status system just begins recording System automatically enables Alarm Record recording function when alarm occurred When input video changes Motion Detection Record system automatically enables record operation Transparent value ranges from 0 Time Title Display to 255 O means completely transparent and 255 is opaque D Channel Title Display Please refer lo the above information Privacy Mask Max supports 8 zones Local Micro SD storage Support Storage high speed card low speed card Based on SDK network storage 2 ch al
27. presets 1 2 7 Auto Scan Camera scans back and forth regularly in a horizontal field Here you need to set left and right limit and scan speed This series IP speed dome max supports 5 scanning paths either via control keyboard or via the menu in screen 1 2 8 Auto Cruise Touring Auto cruise is to add presets into a routine a desired order and then set time and stop duration for each address The dome will begin an auto cruise between these presets System supports 8 cruise paths Each cruise consists of max 32 presets 1 2 9 Auto Pattern Auto pattern is to memorize dome operation such as pan tilt and zoom to repeat Focus and iris are in auto mode during auto pattern This series IP speed dome supports 5 pattern paths 1 2 10 Privacy Masking Privacy masking is a user defined four sided area that can not be viewed by you The masking area will move with pan and tilt functions and automatically adjust in size as the lens zooms You can set 8 privacy masking zones Depends on camera type 1 2 11 Action on Alarm This series speed dome support seven alarm inputs normal close or normal open Each alarm has tree types of PTZ actions It can be individually programmed to initiated pattern or go to an associated preset cruise touring when received The IP dome will return to a previously programmed state after alarm acknowledgement or to its previous position before alarm Forvideo loss alarm or camera masking alarm
28. r Ethernet connection information 2 6 inch IP Speed Dome Router Wireless Router Network User Router Network User Figure 3 6 Please refer to Figure 3 7 and Figure 3 8 for BUS cable connection 14 Input AC 220V 110V Output AC 24V Video Output ontor Power Adapter Figure 3 7 Terminal resistance on Figure 3 8 Note Please use shielded twisted pair The shielded layer shall connect to GND firmly otherwise it may adversely affect communication or video work 3 2 1 2 Star Connection Please refer to Figure 3 9 for start connection information Input RS 485 Figure 3 9 3 2 2 Alarm Connection Please refer to Figure 3 10 for alarm connection information 15 thers Alarm Controller Figure 3 10 3 2 3 Keyboard Connection This series IP speed dome supports keyboard operation You can use keyboard to control the camera and PTZ The display and control can work simultaneously One keyboard can control maximum 255 speed domes Please refer to Figure 3 11 Keyboard 3 11 This series speed dome protocol is open and supports multiple popular system platforms today s market Please feel free to contact us if some matrix systems do not support dome camera communication protocol The most direct and easy way is to use current system to process video signal and add some control keyboards to control speed dome See Figure 3 12 16 Matrix or multiple imag
29. r local national or industry standard System shall adopt equal potential wiring The earth device shall meet anti jamming and at the same time conforms to your local electrical safety code The earth device shall not short circuit to N neutral line of high voltage power grid or mixed with other wires When connect the system to the earth alone the earth resistance shall not be more than 42 and earth cable cross sectional area shall below 25 mm2 See Figure 11 1 Video Lighting Rod Communication _ Liqhting Rod Power Lighting Rod The speed dome shall be installed within the 45 angel of the lighting rod Earth cable resistance shall be less than 40 Steel tube shield Figure 11 1 34 12 Appendix About RS485 Bus 12 1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120 Its max load amount is 32 effective loads including main control device and devices to be charged 12 2RS485 Bus Transmission Distance When we take 0 56mm 24AWG twisted pair as communication cable the max transmission distance theoretically are listed below according to different baud rates Baud Max Distance Rate 2400 1800M BPS 4800 1200M BPS 9600 800M BPS In the following situations the max transmission distance shall become shorter accordingly The communication cable is a little bit thin The surrounding environment h
30. set Watch dog max support 35 seconds Interface 7 alarm input ports 2 alarm output ports 1 analog audio input put and 1 analog audio output port 1 analog video port 1 network port RJ45 10M 100M self adaptive Ethernet port 1 Micro SD card port Support high speed card low speed card Installation Suspended wall mount and embedded installation 27 8 Factory Default Setup Function Configuration Item Name Default setup Type General Setup Date format Y M D DST Disable Date separator au Time format 24H Language Simplified Chinese When HDD is full Overwrite Record duration 60M Device No 8 Video type PAL Encode Setup Main stream Channel 01 Encode mode H 264 Stream Type Main stream Audio Video Enable audio and video enable Resolution D1 Frame rate 25 Bit stream control VBR Quality Good Bit stream value 2048 interval 50 control Extra stream Stream Type Extra stream Audio Video Enable video enable Resolution QVGA Frame rate 15 Bit stream control VBR Quality Good Bit stream value 384 interval 50 control Video color Brightness 50 Contrast 50 Sautratioon 50 Hue 50 Watermark Enable Watermark all Watermark type character Watermark Digital CCTV Privacy mask Never Time title Enable OSD transparent 128 Channel title Enable
31. t star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 152 Figure 12 5 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jamming decreases thus the signal reliability becomes very low You can see speed dome is not under control or speed dome is running automatically and can not stop 36 ees Main Control Devi scx Sy ain Control Device Figure 12 5 In this situation we recommend RS485 distributor This device can turn star type connection into the connection that conforms to RS485 bus industry standard which can avoid the above mentioned problems and enhance communication reliability See Figure 12 6 Figure 12 6 12 5 RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome Host address baud rate and Modify host or speed dome setup can run self speed dome address baud rate e Switch RS485 positive end and diagnosis but I are not match negative end can not control Positive and negative end of Fix connection cable firmly it RS485 Bus are misconnected Replace RS485 Bus Connection cable is loose RS485 Bus connection are cut off can control RS485 Bus connection are Connect RS 485 Bus again the speed good Replace RS485 Bus dome but is not RS485 bus is off

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - 608.81 KB  Set-Up Guide  InterImage 1.41 User Guide - Computer Vision Lab - PUC-Rio  Instruction Guide GM1118  Lenovo Laptop S710 User's Manual  取扱説明書 - 鶴賀電機  NeXus-10 Mark II - Music Cognition Lab  Neurosign 100 Manual Del Usuario 9883-23-16  平成 17 年度 ファイル基準総括表 1 9 1 9 2 11 2 11 3 11 3 12  Samsung SCX-4623FN Manual de Usuario  

Copyright © All rights reserved.
Failed to retrieve file