Manual - Induo Net

image

Contents

1. Chapter 3 Hardware Installation 3 1Hardware installation 3 1 1Unpack switch and check the accessory with packing content list 3 1 2 Mount the switch on desired position For the best ventilation it is suggested to mount the switch on metallic surface 3 1 3 Connect the M23 M12 connector of power input The PoE power supply for IPES 0008B series is connected via a 5 pole M23 female connector while IES 0008B is with a 5 pole M12 female connector m Voltage of Power Input For IPES 0005B 0008B series the voltage of power input should use 48VDC to feed power IEEE 802 3af standardized devices or 54VDC for IEEE 802 3at standardized ones For IPES 0005B 0008B 12V series the power input voltage can be from 9 2V to 56VDC to feed power on both the 802 3af and 802 3at standardized devices With IPES 0005B 0008B 72V series the power input voltage can be from 72V to feed power on both 802 3af at standardized devices ES 0008B series can accept power input ranging from 9 2V 72V 12V 72V to be powered Please make sure that the external power supply unit you use to provide the PoE voltage meet the following criteria e The output voltage of power supply must exceed 48VDC for 802 3af and 53VDC for 802 3at operation with IPES 0005B 0008B 72V only 72VDC can power both the 802 3af and 802 3at PD e The power consumption can satisfy the total power request from all PD devices required Power Power EN V4 E O O j on
2. Ethernet Data 9 5 56VDC for PoE feeding 12V model 48V model 45 56VDC dual input 72V model 50 4 90VDC dual input 10W for 12 24 48VDC 13 5W for 72V 150W for 45 56V input 55V input is recommended for 802 3at 30W applications 80W for 12V input 120W for 24V input 120W for 72V Input 5 to 95 Non condensing 40 C 75 C 40 F 167 F 40 C 85 C 40 F 185 F Aluminum case IP 41 135mm W x165mm H x62mm D 700g Din Rail Wall Mount Design FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 6 2 CE EN61000 6 4 IEC61373 Shock EN61373 Shock and Vibration Testing Certificate EN50155 EN50121 3 2 EN50121 4 Certificate s amp Report EN45545 2 R24 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 amp 2 Fire amp Smoke Certificate 5 years Optional IES IPES 0008B series Hardware Specification IEEE Standard IEEE802 3 10BASE T Ethernet IEEE802 3u 100BASE T Ethernet IEEE802 3x Flow Control and Back Pressure IEEE802 3at af Power over Ethernet Transfer Rate 14 880pps for Ethernet port be 148 800pps for Fast Ethernet port 8K MAC address table 10 100T 8 x M12 4 pole D coded Female with auto MDI MDI X function Power connector 1 x M12 5 pole A coded Male CSMA CD LED Per unit Power 1 Green Power 2 Green Ethernet Link Activity Green PoE Pin RJ 45 port 1 8 s
3. and time up to 1 mof submersion The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer Normally this will mean that the equipment is hermetically sealed However with certain types of equipment it can mean that water can enter but only in such a manner that it produces no harmful effects Protected against close range high pressure high temperature spray downs Test duration at least 3 minutes Water volume 100 litres per minute Pressure 100 kPa at distance of 3 m Test duration 30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device Test duration continuous immersion in water Depth specified by manufacturer 2 4 LED Indicators The diagnostic LEDs that provide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for the switch AR Power 1 Is active PWR1 Green a E PWR2 Green Power or port failure FAULT CIS A network device is detected The port is transmitting or receiving packets Link Ack Blinking from the TX device P1 P5 P8 Of No device attached a C The port is operating in PoE mode IPES IPES The port is not operating in PoE mode IPES On Off On Off On Off On Off On Off
4. Lantech IPES IES 0005B 0008B Series 5 8 10 100TX w 8 5 POE at af Industrial Un Managed Switch User Manual Aug 2015 Important Notice Lantech Communications Global Inc reserves the right to modify the equipment its specification or this manual without prior notice in the interest of improving performance reliability or servicing At the time of publication all data is correct for the operation of the equipment at the voltage and or temperature referred to Performance data indicates typical values related to the particular product No part of this documentation or information supplied may be divulged to any third party without the express written consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does not include or infer any transfer of ownership Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions FCC Warning This Equipment has been tes
5. ater when tilted up to 15 Spraying water Splashing of water Water jets Testing for Dripping water vertically falling drops shall have no harmful effect Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Water splashing against the enclosure from any direction shall have no harmful effect Water projected by a nozzle 6 3 mm against enclosure from any direction shall have no harmful effects Details Test duration 10 minutes Water equivalent to 1 mm rainfall per minute Test duration 10 minutes Water equivalent to 3 mm rainfall per minute Test duration 5 minutes Water volume 0 7 litres per minute Pressure 80 100 kPa Test duration 5 minutes Water volume 10 litres per minute Pressure 80 100 kPa Test duration at least 15 minutes Water volume 12 5 litres per minute Pressure 30 kPa at distance of3m Powerful water jets Immersion up to 1 m Immersion beyond 1 m Powerful high temperature water jets Water projected in powerful jets 12 5 mm nozzle against the enclosure from any direction shall have no harmful effects Ingress of water in harmful quantity shall not be possible when the enclosure is immersed In water under defined conditions of pressure
6. er components attaching to the system have to meet with the IP41 protection class in order to reach the whole system IP 41 protection E Empty ports must be sealed with the protective caps supplied 15
7. g Pin t Pin assignment of Power input m Redundant Power Input The power input can be supported redundantly The supply voltage is electrically isolated from the housing Note With single power supply of the mains voltage the device will report a power failure You can disable this power fail event via web browser DO Relay P Fail 3 24V I DO Pin assignment of alarm relay break in contact is reported via the relay contact e The failure of at least one of the two supply voltages e The break link status of at least one switch port 13 3 1 4 Fitting the device grounding Install the system in a dry and clean area to protect the switch to get exposed with dirt Plug the connector to the power supply plug then turn on the power supply W Ground The chassis is grounded via a separate ground nut M3 Use toothed locking washers for a good electrical connection Ground screw of IPES 0008B switch 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding A av 4 Ne il Green Whi te MA 2 Drange CN i 1 Orange White Pin assignment of M12 10 100Tx network connector 10 1001 X 1 TX mj ZRX 3 X 4 RX 3 1 6 Check the status of LED make sure the switch was in working status Note m The protection class IP41 is only achieved when bolted together E The oth
8. ical DIMONSION coccocccccccnccnccnconcnnconnnns 6 2 2 Package Content c occcooccccccoccocncococonionncancnnoss 7 2 3 IP Protection coccocconconccnccnccnocnonenncnnoncnnnnns 8 2 4 LED Indicators ocooccoonccccccocconionioncnncnnoncnnons 11 Chapter 3 Hardware Installation 12 Chapter 1 Introduction Lantech IPES IES 0005B 0008B Series is a high performance IP41 industrial switch with 8 5 x10 100TX w 8 5 PoE at af injectors IPES model by M12 connectors which provides L2 wire speed and advanced security function for connecting PD network Specification IES IPES 0005B series IEEE Transfer Mac PoE Pin Assignme nt Power Consumpti on Power Budget Operating Humidity Operating Temperatu re Storage Temperatu re Case EMC Hardware Specification IEEE802 3 10BASE T Ethernet IEEE802 3u 100BASE T Ethernet IEEE802 3x Flow Control and Back Pressure IEEE802 3at af Power over Ethernet 14 880pps for Ethernet port 148 800pps for Fast Ethernet port 8K MAC address table 10 100T 5 x M12 4 pole D coded Female with auto MDI MDI X function Power connector 1 x M12 5 pole A coded Male CSMA CD Per unit Power 1 Green Power 2 Green Ethernet Link Activity Green RJ 45 port 1 5 support IEEE 802 3af at End point Alternative A mode Per port provides 15 4W 30W ability Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 9 5 60DC for
9. ted and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected m Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content Chapter 1 Introduction n annnnnnnnennnnnnnnnnnnnnnnnennunnn 4 Specification oonccoccccncocnconcorncononcnconcorocanonnncnnnnnnss 4 Chapter 2 Hardware DescriptiOND oomcooccoocconccoomoo 6 2 1 Phys
10. ting sometimes also interpreted as International Protection Rating classifies and rates the degree of protection provided against the intrusion including body parts such as hands and fingers dust accidental contact and water in mechanical casings and with electrical enclosures It is published by the International Electrotechnical Commission IEC Solid particle protection The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Object size Level Effective against protected against 0 No protection against contact and ingress of objects Any large surface of the body such as the back of a 1 gt 50 mm hand but no protection against deliberate contact with a body part 2 gt 12 5 mm Fingers or similar objects 3 gt 2 5mm Tools thick wires etc 4 gt 1 mm Most wires screws etc Ingress of dust is not entirely prevented but it must not enter in sufficient quantity to interfere with the 5 Dust protected satisfactory operation of the equipment complete protection against contact No ingress of dust complete protection against 6 Dust tight contact Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water Level Protected against Not protected Dripping water Dripping w
11. upport IEEE 802 3af at End point Alternative A mode Per port provides 15 4W 30W ability Assignment Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 Power Supply 9 5 60DC for Ethernet Data 9 5 56VDC for PoE feeding 12V model ll 48V model 45 56VDC dual input 72V model 50 4 90VDC dual input 10W for 12 24 48VDC Consumption 13 5W for 72V Power Budget 240W for 45 56V input 55V input is recommended for 802 3at 30W applications 80W for 12V input 120W for 24V input 120W for 72V Input 5 to 95 Non condensing 40 C 75 C 40 F 167 F Temperature 40 C 85 C 40F 185 F Temperature Aluminum case IP 41 135mm W x165mm H x62mm D 700g Din Rail Wall Mount Design EMC FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 6 2 CE EN61000 6 4 1EC61373 Shock EN61373 Shock and Vibration EN50155 EN50121 3 2 EN50121 4 Certificate Report EN45545 2 R24 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 amp 2 Fire amp Smoke Certificate 5 years Optional Chapter 2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Aluminum case IP 41 2 2 Package Content Lantech Manual CD Product By request 2 3 IP Protection The IP Code Ingress Protection Ra