Home

Tripp Lite SMART750SLT datasheet

image

Contents

1. SWITCHES LED Indicators Site wiring fault indication Alarms Alarm cancel operation Switches 17 8 min 250w 24 Less than 8 hours from 10 to 90 RBC24 SLT Battery access door Hot swappable user replaceable batteries Automatic voltage regulation AVR maintains line power operation with an input voltage range of 83 to 145 120v 87 to 133 110v 83 to 121 100v Voltage reduction of 12 applies when input is 127 to 145 120v 116 to 133 110v 106 to 121 100v Voltage boost of 17 applies when input is 96 to 108 120v 87 to 99 110v 83 to 90 100v Voltage boost of 32 applies when input is 83 to 95 120v only LEDs indicate line power battery power AVR overload and replace battery status with a 3 LED level meter for load and battery charge level Rear panel site wiring fault LED Audible alarm indicates power failure and overload conditions Power fail alarm can be silenced using alarm cancel switch 2 Switches control off on power status and alarm cancel self test operation rear panel protected switches support nominal voltage selection SURGE NOISE SUPPRESSION UPS AC suppression joule rating UPS AC suppression response time UPS Dataline suppression EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches 480 Instanta
2. powering off connected equipment e Single line TEL DSL and network Ethernet line surge suppression Specifications OUTPUT Output Volt Amp Capacity VA Output Watt Capacity watts Output power factor Nominal Output Voltage s Supported Nominal Voltage details Frequency compatibility Output voltage regulation line mode Output voltage regulation Battery mode Built in UPS output receptacles Surge suppression only outlets Output AC waveform AC mode Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type UPS Input cord length ft UPS Input cord length m Recommended Electrical Service BATTERY Full load runtime minutes 750 500 0 7 100V 110V 120V 120V default voltage selection via back panel switches 50 60 Hz 13 15 5 8 5 15R outlet s 4 UPS outlets 4 surge only outlets Sine wave Pure Sine wave 12A 100V AC 110V AC 120V AC 5 15P 1 8 15A 120V 6 5 min 500w Half load runtime minutes DC system voltage VDC Battery recharge rate included batteries Replacement battery cartridge internal UPS battery replacement Battery Access Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction Severe undervoltage correction LEDS ALARMS amp
3. d hard reboot restart options for remote applications 4 8 milliseconds 95V 120V 87V 110V 83V 100V 145V 120V 133V 110V 121V 100V Cold Start startup in Cold start operation supported battery mode during a power failure High availability UPS Hot swappable batteries features Green amp high efficiency Greater than 95 efficiency GREEN UPS features CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico UPS Certification details EMI approvals Yes WARRANTY Product Warranty Period 2 year warranty 3 year with registration Note registration is required for 3 year warranty Worldwide Connected Equipment 250 000 Ultimate Lifetime Insurance Insurance U S Canada amp Puerto Rico Related Items Optional Products Related Model Description Qty DCATV Network Surge Suppressor Essential protection for TV VCR coaxial lines 1 DNET1 Network Surge Suppressor Essential protection for data and communication lines 1 DTEL2 Network Surge Suppressor Essential protection for data and communication lines 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNUPWEBCARD 1 or switched PDU PDU1215 Basic PDU Power Distribution Unit Safe reliable power distribution for critical 1 networking equipment SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cab
4. ications Communications interfaces support messaging of UPS and line power status plus output power control for delayed or immediate reboot of all connected devices at once Includes PowerAlert UPS monitoring and unattended shutdown software with management support for an unlimited number of network UPS systems Built in audible alarm and LEDs offer status notification for line power battery power battery charge level load level plus AVR boost and trim operational status information Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges Also includes single line TEL DSL or Ethernet line surge suppression Attractive all black tower housing Package Includes e SMART750SLT UPS System e PowerAlert Software CD Rom e USB and serial cabling e User manual with warranty information Features e SMART750SLT line interactive UPS offers battery derived sine wave AC output during power outages voltage regulation during brownouts and overvoltages plus network grade AC surge suppression e 750VA 500 watt power handling capability with full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic devices e Large internal batteries offer runtimes of 17 8 minutes at half load 375VA 250 watts and 6 5 minutes at full load 750VA 500 watts e Automatic Voltage Regulation AVR circuits maintain user selectable 100 110 or 120V nominal o
5. iti Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 ae E mail saleshelp tripplite com Model SMART750SLT SmartPro 75kVA Line Interactive Sine Wave UPS SNMPWEBCARD option Tower USB Serial 100 110 120V Highlights e 750VA line interactive tower UPS Sine wave output e 100 110 120V nominal output during brownouts and overvoltages e USB RS232 and optional SNMP Web card are available for simultaneous use e Detailed status LEDs Single line TEL DSL surge suppression e NEMA 5 15P input 8 NEMA 5 15R outlets Description Tripp Lite s SMART750SLT intelligent line interactive sine wave UPS system protects servers networking accessories and telecommunications equipment from blackouts voltage fluctuations and transient surges Large internal batteries offer 15 minutes half load runtime and 5 minutes fully loaded 750VA 500 watt power handling capability and full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic applications Includes 8 protected NEMA 5 15R output receptacles total 4 of which offer surge suppression only for less critical desktop accessories Supports simultaneous remote monitoring of UPS and site power conditions via built in network accessory card slot USB and DB9 serial monitoring ports Optional SNMPWEBCARD accessory enables remote monitoring of UPS as a managed device via network management console appl
6. le 1 A Male to B Male WATCHDOGSW WatchDog Service Monitoring Reboot Software 1 WEXT5 500 1500 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack 1 models 1500VA or less MODBUSCARD For remote monitoring and control via MODBUS protocol 1 More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 3007 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
7. neous 1 line TEL DSL 1 in 1 out 10 100Base T Ethernet Yes Tower Tower 10 2x6 8x9 UPS Power Module dimensions in primary form factor height x width x depth cm UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg Cooling method UPS housing material ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load Battery mode BTU hr full load Audible Noise COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable WatchDog compatibility LINE BATTERY TRANSFER Transfer time Low voltage transfer to battery power setpoint High voltage transfer to battery power setpoint SPECIAL FEATURES 26 x 17 1 x 22 9 30 13 6 13 8 x 9 8 x 13 2 34 9 x 24 8 x 33 7 32 14 5 Fan Steel 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 70 8 728 6 Audible Noise lt 50 dBA at Front Side 1 Meter USB DB9 Serial Slot for SNMP Web interface Supports detailed monitoring of UPS and site power conditions Included USB and DB9 cabling included Supports Watchdog application OS an
8. utput over an input voltage range of 83 to 145V e Includes 8 NEMA 5 15R output receptacles total 4 with UPS and surge suppression for critical devices and 4 with surge only protection for less critical accessories e PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging email notification event logging and running user defined script commands e Offers simultaneous monitoring by up to 3 directly connected devices through included USB DB9 and SNMP interfaces requires optional SNMPWEBCARD or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software e Communications ports support messaging of UPS and line power status including on battery low battery power restored AC line voltage DC battery voltage and remaining battery capacity e Supports timed inverter shutoff after unattended shutdown activate self test and UPS output power control for delayed or immediate reboot of connected equipment e Supports Tripp Lite s WatchDog software application to restore unresponsive programs by systematically restarting applications operating systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again requires optional WATCHDOGSW e Status LEDs offer continuous status information of UPS operating parameters and site power quality e Hot swappable batteries allow on site battery replacement without

Download Pdf Manuals

image

Related Search

Related Contents

Notificación de los acuerdos adoptados en  iStarUSA DAGE840-ES  MANUEL D`UTILISATION  Dataram 32GB DDR3-1333 PC3L-10600L 240-pin LRDIMM  E6580850 - TMEIC 東芝三菱電機産業システム株式会社    „Bio-psycho-soziale Prädiktoren der Frühgeburtlichkeit und  falling weight deflectometer relative calibration analysis    Documentation X2 - Infosec  