1. ClockWatch    User Manual          interspace _  industries    Cueing and Presentation Control Specialists    Contents     Introduction    Environmental   Electrical Compliance    Safety Instructions    Diagrams    Regulations Compliance    Operating Instructions    Programming    Technical Support Contact    Introduction    ClockWatch combines clear traffic light type signalling with a simple to use timekeeping  system  The intuitive control module has been designed especially for non technical users so  that formal timekeeping can be easily managed in a wide variety of applications     Signalling to speakers to ensure everything runs to time is the key to a smooth  professional  meeting and ClockWatch silently prompts presenters when to speak  green light   when to  summarise  amber light  and when to finish  red light   Feed back to a timekeeper and or the  meeting chairperson can also be provided via a variety of visual or numeric displays     Designed for reliability and versatility  ClockWatch is based on AV industry proven rugged    design  uses readily available 3pin XLR  mic  cable connectors and the system can be set up  in just 1 2 minutes  or be permanently installed if required     Meeting Control Made Easy     We hope ClockWatch exceeds your expectations and welcome any feedback that you have  about this or any of our products     Thank you     The Interspace Industries Team  www interspaceind com    Environmental    WEEE and RoHS Compliance  ClockWatch and its 
2. associated accessories have been  manufactured and sold in accordance with the requirements of the EC WEEE and RoHS  directives  Please return all end of life items to your supplier  or Interspace Industries directly   for appropriate disposal     Packaging Materials   Cardboard box  Grade 150 K T    B     Single Walled Corrugated   Brown Kraft   Protective Foam  Grade HLB 22 Grey Foam  High Load Bearing     Electrical    CE Mark  ClockWatch and its associated accessories have been designed  manufactured  and certified to comply with all requirements ofthe European CE standard     Safety Instructions    All safety and operating instructions should be read before this product is operated and  should be retained for further reference  Please adhere to all the warnings on this product  and in these operating instructions  Please follow these instructions carefully     Power  Only use the power source indicated on the device  Devices equipped with a  grounded plug should only be used with a grounded type outlet  In no way should this  grounding be disconnected  modified or suppressed     Power Supply Lead  To unplug the device always pull by the plug itself  not the power  supply lead  The power source outlet should always be near the MicroCue main unit and  easily accessible  Ensure the power supply lead cannot be walked on or damaged by items  placed on or against it  Do not use if the power supply lead is damaged  Using the device  with a damaged power supply lead may expose y
3. button 3  The system then stores the new sequence and resets  This new    sequence will now run each time the PRESET button that was chosen in 1 above is  pressed     For Technical Support or Sales Enquiries  Interspace Industries Head Office    44  0  870 770 8088  Emergency Technical Support Hot Line    44  0  7976 385046    Website     www interspaceind com    interspace _  industries       28 High Street   Arlesey   Bedfordshire   SG15 6RA   UK   Tel   44  0  870 770 8088   Fax   44  0  870 770 8089   Email  moreinfo interspaceind com  www interspaceind com    
4. ce is running  any of the LightTower lamp control  buttons KD   O Or can be pressed  This immediately illuminates whichever lamp has  been selected and cancels the timer sequence     Programming Preset Timing Sequences     1     After resetting ClockWatch by briefly pressing the RESET button  press and hold the  RESET button    together with whichever one of the preset time sequence buttons     that you wish to program  Hold both buttons down for around 5 seconds   When the preset button glows brighter  ClockWatch is now in programming mode and  you can release both buttons  When programming a new timing sequence  the system  assumes the LightTower is always going to start from Green when the timing sequence  commences     To program the time interval until the LightTower turns from Green to Amber  pressing  the PAUSE button  amp  increases the time interval by 5 seconds  To decrease the time  interval  press the PAUSE button    while holding down the RESET button 9  The  numeric display    updates with each press of the PAUSE button     you can see  the time interval you are programming     When the required interval has been programmed  release all buttons then momentarily  press the AMBER button O  The system is now ready to program the time interval until  the LightTower changes from Amber to Red     To program the time interval until the LightTower changes from Amber to Red  repeat  step 2 above  When the required interval has been programmed  momentarily press the  RED 
5. he source     Quick Start Operation   Manual Mode  By simply pressing any of the LightTower lamp  control buttons Q or     the corresponding lamp on the LightTower and or visual  displays will illuniMate atcordingty  The selected lamp will remain illuminated until either the  same button is pressed again  this extinguishes the lamp   or an alternative coloured lamp is  pressed  It is not possible to have more than one coloured lamp illuminated     By pressing the PAUSE button Q   any of the LightTower lamps are illuminated  the  lamp will flash intermittently  thus Signalling that the time keeping has been paused  Pressing  the PAUSE O  will stop the lamp from flashing     Quick Start Operation  Auto Mode   Refer to    Programming    section overleaf for instruc   tions on how to pre program the preset time sequence buttons   By pressing either of the  preset time sequence buttons  A    the pre programmed timer sequence starts immedi   ately and the LightTower m urs according to the pre programmed timing profile  At  any time during the timer sequence  the PAUSE button Q can be pressed to pause the  sequence  While paused  the LightTower lamp will flash intermittently to signal that the se   quence has been paused  To resume the timing sequence  press the PAUSI  pp tton  again     6    Should it be necessary to cancel a timing sequence  simple press the RESET button       This extinguishes all displays and resets the timer display O    At any time while a preset timing sequen
6. ou to electric shock or other hazards   Check the condition of the power supply lead regularly  Contact your dealer or service centre  immediately for a replacement if damaged     Keep Away From Harmful Substances    To prevent the risk of electric shock and fire  do not expose this device to rain  humidity or  intense heat sources  such as radiators or direct sunlight   Avoid using this equipment in  environments where there is excessive heat  dust  moisture  chemicals  vibration or  mechanical shocks     Slots and Openings  These are designed into the device for ventilation and to avoid  overheating  Always ensure these openings remain clear  Do not attempt to insert  anything into these openings under any circumstances  If liquids have been spilled on   or objects have fallen into the product it must be checked by a qualified technician before re   using     Connections  All inputs and outputs  except for power input  are TBTS defined under  EN60950     eo DO NOT OPEN SYSTEM DUE TO HIGH VOLTAGE      DO NOT IMMERSE IN WATER     If you have any queries regarding these safety instructions or how to maintain the unit please  do not hesitate to contact us on      44 0 870 770 8088    Servicing  Do not attempt to service this product yourself  Opening or removing covers and  screws may expose you to electric shocks or other hazards  Refer all servicing to qualified  service personnel     Diagrams       Figure 1  ClockWatch Connections Diagram                 Iter Lamga A Light T
7. ower labi Larga A Muse Dalas O HA LISA Mun  On On apum    Clock Watch            j meri pace laua ry  A We iera ponad com RoHs         Figure 2  ClockWatch Front and Rear Panel Controls    5    DECLARATION OF CONFORMITY    We declare under our sole responsibility that the product    ClockWatch    To which this declaration relates is in conformity with the following standards or other norma   tive documents     EN55103 1  amp  EN55103 2 1966  Specific for professional Audio Visual Products   Used in  environment as defined under E2 Commercial and Light industry  example Theatres     EN60950 1   2000  Following the provisions ofthe EEC Directive 89 336 EEC and 73 23 EEC    pro  kg    Dave Humphrys F  Managing Director  Interspace Industries Ltd Issued on  Date 14 May 2008    Operating Instructions    Unpacking and Connections  Unpack the main unit and place on a flat surface within easy  access for the Operator  Adjust the angle of the main unit by loosening the bracket securing  fasteners on each side of the main unit and re tightening once the most comfortable angle is  achieved     Position the LightTower and any other display units for best viewing and connect the Light   Tower s  to connections  amp    and any numeric or intelligent lamps to connections    8  ga on the rear panel 9  Q unit using 3 pin XLR  mic  cables  see figures M  maxtnum combined cable distances can be as much as 100m  300ft      Connect the IEC power cable    to ClockWatch and switch on the power at t
    