Home
Handheld Laser Distance Meter
Contents
1. Handheld Laser Distance Meter i User Manual English Congralulalions on the purchase of your products Carefully read the Safety Instructions and the User Manual before using this product A The person responsible for the instrument must ensure that all users understand these directions and adhere to them Safety Instructionsisnte Raina casas ves 2 Start up e AR i ine ini ne sheets RITI 7 Menu functions 25k siii dirai ne 11 OPETTAA Osana S E ie n AI Sesser 12 MeasurinE enmi a sesti e atest i 13 Function Saem iaeiae anehi a i 15 APPEND sin mee SE ian iron 21 Safety Instructions Symbols used The symbols used in the Safety Instructions have the following meanings WARNING Indicates a potentially hazardous situstion or an unintended use which if not avoided will result in death or serious injury CAUTION Indicaes a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appr eciable material financial and environmen tal damage Se Important paragraphs which must be adhered to in practice as they enabled the product to be used in a technically correct and efficient manner Use of the instrument Permitted use Measuring distances Computing functions e g areas and volumes Indirect measurement Addition and subtraction operations of measurement Prohibited use Using the instrument without instruction Using o
2. Battery0 Standard supply part Laser Distance Meter 1 portable belt 2 battery 1 operating instructions 1 protective bag 1 warranty card Measurements button pressed long Press once again to change the unit of distance measurement The following units are available m meter ft feet in inch ft in feet inch 1 16 Beep ie button press long You can choose the beep on or off as required Laser Continuous Press and hold down the key when switching on the device until the character appears permanently int display with beep sounds Every further press of the key releases a distance measurement Press the key and hold to switch the device and laser continuous operation off Measuring with tripod The reference must be appropriately adjusted in order to be able to take correct measurements with a tripod You can switch the reference by a button The setting can be shown on the display Illuminating display fg e button press short the illuminating display can be turned on or off The Correction of tilt sensor Press this button to enter into the Tilt sensor mode Continuously press this button five times again when the bottom of display shows 0 0 Then press button once to see the display shows 0 1 Wait for five seconds and rotate the instrument by 180 degree Press the button once and it shows 0 2 wait several seconds till it shows 0 0 for finishing th
3. G 3 Si Ea fe a 2 3 c 3 3 F 3 3 c 3 3 f D f 3 3 2 Q S SI E e E G 3 f D a i o 3 a 3 g a D 2 3 Fi 2 Q S Automatically 0 C to 40C 20 C to 70C E 3 5 9 I S a D 5 a ci 2 o F f mpe ral Battery le 5000 to 8000 measurements I After 30 seconds After 3 minutes without battery os EI lt LR6 AA 2 x 1 5V After 30 seconds After 3 minutes 118 x49 x27 mm 1509 a a 3 S e c a d 6 Gi 3 S a without battery maximum deviation occurs under unfavourable conditions such as bright sunlight or when measuring to poorly reflecting or TE 8 e eee ZSY very rough surfaces Measuring accuracy between 10 m and 30m may deteriorate to approx 0 025 mm m for distances above 30m to 0 1 mm m the tool is maintained good technical condition This means that in the tool can be used in the company s original components and spare parts This warranty is provided in the tool during the whole life expectancy of the defective parts of the Measuring conditions Measuring range repaired or replaced free of charge If the component due The range of 100m instrument is limited to 100m The j to normal wear and in need of repair or replacement is range of 80m instrument is limited to 80m not in the warranty van At night or dusk and if the target is in shadow th
4. about a fixed point e g with the positioning bracket fully folded out and the instrument placed ona wall e The minimum maximum function can be used see explanation in Measuring gt Minimum maximum measurement The minimum value must be used for measurements at right angles to the target the maximum distance for all other measurements Make sure that the first measurement and the distance to be measured are at right angles Use the Minimum maximum function as explained in Measuring gt Minimum maximum measurement Indirect measurement determining a distance using 2 auxilliary measurements e g for measuring building heights or widths i It is helpful to use a tripod when measuring heights that require the measurement of two or three measurements 4 Press this button once the display showsd The laser is switched on Aim at the upper point 1 and trigger the a measurement After the first measurement the value is adopted The result is displayed in the summary line the partial results in the secondary line Such as angle and distance If bevelangle gt 45 Need to measure 2 Press this button closed angle sensor Shall be measured again point 1 in the distance After the measurement is completed Keep the instrument as horizontal as possible Press and hold down this button to trigger continuous measurement sweep the laser back and forth and up and down over the ideal target point Pr
5. service of this machine will be from the date of manufacture
6. system must be configured and operated in such a way thatin case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur A WARNING Flat batteries must not be disposed of with household waste Care for the environment Always prevent access to the product by unauthorized personnel and take them to the collection points Z provided in accordance with national or local provided in accordance with national or local regulations The product must not be disposed of wit household waste Dispose of the product appropriately in accordance with the national regulations in force in your country TTT TTT ZII YI 55 di e eee Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment AWARNING The products conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of it causing interference in other devices cannot be totally excluded ACAUTION Never attempt to repair the product yourself In case of damage contact the local dealership Laser classification Integrated distancemeter A A The produces a visible laser
7. beam which emerges from the front of the instrument It is a Class 2 laser product in accordance with e IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it to wards other people unnecessarily Eye prote ction is normally afforded by aversion respon ses including the blink reflex RIC a o 2 Insert batteries observing correct polarity A WARNING 3 Close the battery compartment again Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous Replace the batteries when the symbol Precautions flashes permanently in the display Do not look directly into the beam with optical aids E onl lkali h bl nly use alkaline or rechargeable Acaution batteries Looking into the laser beam may be hazardous to the eyes gt Remove the batteries before any long Precautions period of non use to avoid the danger of Do not look into the laser beam Make sure the laser is corrosion aimed above or below eye level particularly with fixed installations in machines etc Labelling Changing the reference point multifunctional endpiece The instrument can be adapted for the following measuring situations For measurements from an edge fold out the positioning bracket until it first locks in place For measurements from a corner open the positioning bracket until it locks in plac
8. d minimum distances are shown in the display as well as the last measured value in the summary line min jd J nN E mas Addition subtraction Distance measuring W The next measurement is added to the previous one The next measurement is subtracted from the previous one This process can be repeated as required The last step is cancelled Area Press once The4 Z7 symbol appears in the display Press this button to take the first length measurement e g length 4 Press it again to take the second length measurement e g width The result is displayed in the summary line Volume Q Press this button twice ThefPsymbol appears in the display Press this button to take the first length measurement e g length G Press this button to take the second length measurement e g width Press this button to take the third length measurement e g height The volume then appears in the summary line Tiltmeasurement Long press this button once to activate the tilt sensor The tilt degree data and tilt symbol or tappears in the display Press to measure the inclination and the distance Indirect measurement The instrument can calculate distances using Pythagoras theorem Make sure you adhere to the prescribed sequence of measurement Alltarget points must be in a horizontal or vertical plane e The best results are achieved when the instrument is rotated
9. e then push the positioning bracket lightly to the right to fold it out fully A built in sensor automatically detects the orientation Inse rting replacing batteries of the positioning bracket and adjusts the zero point of the instrument accordingly For measurements from an edge fold out the positioning bracket until it first locks in place Coo O a 1 Remove battery compartment lid and attach handstrap e For measurements from a corner open the positioning bracket until it locks in place then push the positioning bracket lightly to the right to fold it out fully A built in sensor automatically detects the orientation of the positioning bracket and adjusts the zero point of the instrument accordingly Keypad ON DIST On measuring button Plus button el Minus button Area volume button Angle button Reference button Indirect measurement Pythagoras button Background light Units button Storage button rit Timing button clearn off button D OMONDUAWNHH isplay Laser active Reference Indirect measurement Pythagoras Delay measurement Area volume measurement Stored record Data display Display unit Battery status Hardware failure The dynamic continuous measurement Marking function Operation error indication mM 23121 1C Pieri Ed P Su panne Battery state indicator UNDER Battery100 Battery75 Battery50 Battery25
10. e correction Press this button for exiting Operation Switching on and off Switches on the instrument and laser The digplay shows the battery symbol until the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after three minutes of inactivity Clear button ee The last action is cancelled While making area or volume measurements each single measurement can be deleted and remeasured in series Refenece setting The default reference setting is from the rear of the m E instrument The display will show you Press this button a measurement will be extended along as the reference edge The display will show youll Press this button will measure the reference edge fixed to the forefront The display will show youl a Press this button the rear reference is set again Level You can choose the level gauge on or off as required by press this button E Single distance measurement Press to activate the laser Press again to trigger the distance measurement The result is displayed immediately Tiltmeasurement rhe tilt sensor measures tilts between 45 During the measurement of tilt the instrument should be held without transverse tilt as far as possible 10 Horizontal measurement Press button to activate horizontal measurement in the instrument Th
11. e following symbol appears in the display If the button is active the horizontal distance is displayed in the summary line for each distance measurement up to max 45 and up to max a transverse tilt of 10 Press the button to collect the measurement data and the data will be on the display And the height distance horizontal distance hypotenuse distance and angle will be showed on auxiliary display in turn Timer self triggering Press this button to set a 5 second time delay orf Press and hold down this button until the desired time delay is reached max 30 seconds Once the key is released the remaining seconds until measurement e g 29 28 27 are displayed in a countdown The last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed rhe timer can be used for all measurements Minimum maximum measurement This function allows the user to measure the minimum or maximum distance from a fixed measuring point It can also be used as to determine spacings It is commonly used to measure room diagonals maximum values or horizontal distances minimum values Press and hold down this button until you heara beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the rr e eforo aaoeSoO t ca corner of a room Press to stop continuous measurement The values for maximum an
12. e measuring range without target plate is All illustrations descriptions and technical increased Usea target plate to increase the specifications may be subject to change without prior measurement range during daylight or if the notice target has poor reflection properties Target surfaces Measuring errors can occur when measuring toward colourless liquids e g water or dust free glass Styrofoam or similar semiperme able surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors Against non reflective and dark surfaces the measuring time may increase Care Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Handle the instrument as you would a telescope or camera Warranty The instrument comes with a one year warranty This warranty effective premise is according to the company s operating instructions for correct operation processing cleaning and maintenance of the tool and es Serial number Product name Laser distance meter Product type Date of purchase Name of purchaser Phone Address Zip code Distribution name Dealer seal The whole of laser distance meter Battery target board hand strap soft package packaging and other auxiliary equipments are not in the free maintenance range Not registered of purchasing date on the warranty card the free maintenance
13. ess to stop continuous measurement 2 The result is displayed in the summary line the partial results in the secondary line Such as bevel edge and angled edge distance Indirect Measurement determining a distance using 3 measurements Press this button twice the display shows the following symbol amp The laser is switched on Aim at the upper point 1 and trigger the measurement After the first measurement the value is adopted The result is displayed in the summary line the partial results in the secondary line Such as angle and distance If bevel angle gt 45 Needto measure 2 PR Press this button closed angle sensor Shall be measured again point 1 in the distance After the measurement is completed Keep the instrument as horizontal as possible Press and hold down this button to trigger continuous measurement sweep the laser up and down over the ideal target point Press to stop continuous measurement 2 The value is adopted Aim at the lower point and n Press this button to trigger the measurement 3 The result is displayed in the summary line the partial results in the secondary lines Storage of constants historical storage Historical storage Press this button for long time theicon will show on the display and the previous 10 results measurements or calculated results are shown in reverse order The and buttons can be used for navigation Make it availab
14. le constant for further calculations by pressing button Message codes All message codes are displayed with either or Error The following errors can be corrected Calculation error Receiving the reflected light too weak or too strong Measurement time too long Reoperation change a better surface reflecting or using target plate The goal of the ambient light is too strong Change the light for measuring Cool down or Warm up the instrument External Temperature will be available from 0 C to 40 C Temperature too high 40 C or too low 0 C Switch on off the instrument several times If the symbol still appears then your instrument may be defective Please call your dealer for assistance 2800 Hardware error Technical data ITEM 100m instrument 80m instrument 0 05 to 80 M Typical 2 mm 620 690nm lt 1mW Class 2M Il 620 690nm lt 1mW 45 Horizontal measurement range Show beep Multifunctional end piece Automatically Protection against splashes and du Historical storage Tet rature range for Operation 0 C to 400 Bi sele 0 3 E o 3 3 g 3 D a S a 3 3 g E Pj Q lt A D lt e Si 3 F D a a Si 2 g 2 3 D a a 3 o a p s Fa D a e S g a 2 3 ao 9 s D g 3 5 E
15. s of these safety concepts in combination with the products equipment Responsibilities of the person in charge of the instrument A WARNING The person responsible for the instrument must ensure that the equipment is used in person is also accountable for the deployment of personnel and for their accordance with the instructions This training and for the safety of the equipment when in use The person in charge of the instrument has the following duties To understand the safety instructions on the product and the instructions in the User Manual e To be familiar with local safety regulations relating to accident prevention To inform Leica Geosystems immediately if the equipment becomes unsafe Hazards in use 4 CAUTION Watch out for erroneous distance measure ments if the instrument is defective or if it has been dropped or has been misused or modified Precautions Carry out periodic test measurements Parti EEE a SI cularly after the instrument has been subject to abnormal use and before during and after important measurements Make sure the optics is kept clean and that there is no mechanical damage to the bumpers 4 CAUTION In using the instrument for distance measure ments or for positioning moving objects e g cranes building equipment platforms etc unforeseen events may cause erroneous mea surements Precautions Only use this product as a measuring sensor not as a control device Your
16. utside the stated limits Deactivation of safety systems and removal a O SE of explanatory and hazard labels Opening of the equipment by using tools screw drivers etc as far as not specifically permitted for certain cases Carrying out modification or conversion of the product Use after misappropriation Use of accessories from other manufacturers without the express approval of our company Deliberate or irresponsible behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected Aiming directly into the sun Deliberate dazzling of third parties also in the dark e Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Limits of use See section Technical Data The poduct is designed for use in areas perm nently habitable by humans do not use the productin explosion hazardous areas or in aggressive environments Areas of responsibility As the original producer responsibility Responsible for providing security products include manual and origin of the parts j Responsibilities of the manufacturer of non Original accessories The manufacturers of non Original accessories for the products are responsible for developing implementing and communicating safety concepts for their products They are also responsible for the effectivines
Download Pdf Manuals