Home

USER MANUAL

image

Contents

1. Digital Torque Angle Adapter Digita Torque Angle Adaptor Model No RAISATA Squore Drive Y A200 Nem 295 M75 off MANUAL EM MEM PIT Y ANG Vol 1 1 Sep 2010 Digital Torque Angle Adaptor Thank you for choosing RJ series digital torque angle adaptor Please read instruction carefully before using You will find this RJ series Digital Torque Angle Adaptor easy to use Turn it on and apply the Digital Torque Angle Adaptor Digital loque Model No RL IS2ITA Drive ra 40 200 m 295 MS loft 380 MEM CONTENTS 1 Product Specifications 2 Components and Features 3 How to use Digital Torque Aangle Adaptor m 3 1 Battery Installation and Replacement B 3 2 Power On E 3 3 How to use Angle functions m 3 4 How to select UNIT kg m lb ft N m m 3 5 How to set Target Torque Value B 3 6 How to set Peak and Track E 3 7 L C D Backlight optional B 3 8 Turn Off m 3 9 Memory 4 Care and Cleaning 5 Importment safeguards 1 Product Specifications Model No _Ke1s0212 Torque Accuracy 2 Angle Accuracy 1 of reading 1 angular velocity gt 10 sec lt 180 sec 1 of Text Texture Memory 50 Display resolution Torque 0 1 Angle 1 Display Range 40 200N m 29 5 147 5lb ft Angle 5 360 Drive 1 2 inches Unit Selection kg m lb ft N m Weight 280 g Battery Life 110hrs continuous operation Operating Ambient
2. 2 Components and Features Digital loque Angle Adaptor Model No R PEZITA Squore Drive Wt 40 200 Nem 295 4 5 tf 5 30 MEM Angle Increase Peak Trace Clear Memory XX Backlight 3 How to use Digital Torque Angle Adaptor Do not press M and button together please The system will enter into Calibration Mode Turn off power please EX Battery Install and Replacement 1 AAx2 2 Keep the end thread clean and dry for a good contact 3 Open the battery cap 4 Remove the old battery 5 Install 2 pcs AA Battery in the housing with the sign facing upwards 6 Screw the battery cap 1 When battery are low a NI icon will light 2 Remove the battery if stored for a long period of time 3 Battery life depends on battery quality and the amount of the lights and buzzer are used 4 Typical life is up to 110 hours EE Power On 1 Press and release the button to turn the adaptor on The LCD panel shows tr ALE 2 After 2 seconds the L C D panel show 00 0 3 Swing the ratchet 4 The L C D displays the torque value measured If you do not use the ratchet for 80 seconds the digital angle adaptor will automatically shut off How to use Digital Torque Angle Adaptor EX How to use Angle functions 1 Place the adaptor on a flat surface 2 Press and release Angle
3. Temperature 10 C 60 C 13 9 F 139 9 F Storage Temperature 20 C 70 C 4 F 157 9 F Operating relative humidity 15 to 90 noncondensing Auto shut off 80 seconds if do not use Model No DREI Torque Accuracy 2 Angle Accuracy 1 of reading 1 angular velocity gt 10 sec lt 180 sec 1 of Text Texture Memory 50 Display Range 27 135N m 19 9 99 6lb ft Angle 5 360 Operation Mode Peak Track Unit Selection kg m lb ft N m Dimension 75mm W 101mm Weight 270g Battery Life 110hrs continuous operation Storage Temperature 20 C 70 C 4 F 157 9 F Operating relative humidity 15 to 90 noncondensing Auto shut off 80 seconds if do not use ratchet Product Specifications Model No E1912 Torque Accuracy 2 Angle Accuracy 1 of reading 1 angular velocity gt 10 sec lt 180 sec 1 of Text Texture Memory 50 Display resolution Torque 0 1 Angle 1 Display Range 6 30 N m 4 4 22 1lb ft Angle 5 360 Drive 1 4 inches Operation Mode Peak Track Unit Selection kg m Ib ft N m Weight 200 g Battery Life 110hrs continuous operation Operating Ambient Temperature 10 C 60 C 13 9 F 139 9 F Storage Temperature 20 C 70 C 4 F 157 9 F Operating relative humidity 15 to 90 noncondensing Auto shut off 80 seconds if do not use
4. button 3 The L C D will show 0000 0 4 The L C D will show 0 5 Swing the wrench 6 The L C D displays the angle value measured CCW 5 6 20 CW 5 6 207 7 Stop use digital torque angle adaptor when the degree reach you need 8 The angle value and torque value will flash alternately for 10 seconds for example 20 15 but this mode must be under the Pear mode EX How to select Unit Press M and P T button together and release to select different torque units 1 When you change units the target setting will also be changed to the new units value 2 This digital ratchet contains 3 unit selections kg m ft Ib N m 3 3 color LED light indicator How to use Digital Torque Angle Adaptor EE How to select Target Torque Value 1 Increase 1 Press and hold the button to increase the current target value 2 The target will show for 10 seconds 3 After 10 seconds the LCD display 0 00 2 Lower 1 Press and hold the button to lower the current target value 2 The target will show for 10 seconds 3 After 10 seconds the LCD display 0 00 Dice 3 color LED light indicator 1 Green light When you start to use digital torque angle adaptor the LED idicato will flash green 2 Yellow light When you are approching 20 before the target yo
5. aptor stores the last 50 torque value readings Important Safeguards Do not press M and D button together please The system will enter into Calibration Mode Tun off power please E Store in a clean dry place Use a soft dry clean cloth clean the adaptor and L C D panel m Basic safty precautions should be observed especially when using the adaptor on or near children and disabled presons E Never submerge the adaptor in water or any other liquid m Never clean the ratchet with organic solvents E Use the adaptor only for the intended use described in this manual m Do not exceed the permitted torque value for the adaptor amp Do not use the adaptor if it is not working properly or if it has suffered any damage Do not disassemble the digital adaptor m Do not expose the adaptor to extreme temperature humidity direct sunlight or shock violently m Do not shake or shock m To ensure accurate measurement periodic recalibration is necessary
6. u will see a flash yellow and hear an intermittent buzzer warring that the torque is close 3 Red light When the target values is attained the LED will change red light and an buzzer will sound EE How to set Peak or Track Peak 1 Press and release P T button when the digital adaptor is on 2 The L C D panel shows Peor 3 The L C D panel shows 00 0 after 2 seconds Track 1 Press and release P T button when the digital adaptor is on 2 The L C D panel shows Er ALE 3 The L C D panel shows 0 00 after 2 seconds How to use Digital Torque Angle Adaptor L C D backlight Optional On Press and release the 9 button Off Press and release the XX button one more time Turn Off 1 If you do not use the adaptor for 80 seconds the digital adaptor will automatically shut off 2 To manually turn off the digital adaptor press XD button for 3 seconds then release Memory 1 To display this store reading The digital torque angle adaptor must be turned on 2 Press M button at least 1 second and release 3 The display show the memory number is P01 then Torque Value 4 Press M button at least 1 second one more time 5 The displeay show the memory number is PO2 then Torque Value 6 P01 is the latest reading P50 would be the oldest 1 This Digital Torque angle ad