Contents
1. Low Temp Threshold Standby Mode 1 6 5 Notifications The GSM TSDA transmits ALARM SMS notifications to the numbers registered 1SMS 6SMS Diag 5 The primary number registered at 1SMS will receive SMS notifications containing the selected settings Item 2 4 diag 8 Test status SMS notifications showing remaining SIM card balance and Auto Reset to Armed On Guard mode Diag 6 Test status SMS notifications are sent depending on the interval selected Table 4 Cell 14 The interval time reference point is established and starts upon the receipt of the settings notification When an Alarm is triggered the GSM TSDA will transmit an SMS notification place a call to the first registered primary number and will then place calls to the remaining numbers together with transmitting SMS notifications up to six 6 numbers The GSM TSDA will cease calling the first number and will proceed to call the next number under the following circumstances When the subscriber disconnects the incoming call When the subscriber does not respond by picking up within 30 seconds When the subscriber s line is busy When the subscriber is out of network Calling out will cease after one of the subscriber numbers picks up and disconnects then the GSM TSDA will transmit Alarm Diag 5 notifications to the numbers located at cell positions 2SMS 6SMS
2. SENAL ALPHA ARSENAL ALPHA ARSENAL ALPHA ALPHA ARSENAL ALPHA ARSENAL ALPHA ALPH POLUS GSM Thermo Sensor Detector WIRELESS PROTECTION FOR YOU AND YOUR FAMILY Operating Manual POLUS GSM THERMO SENSOR DETECTOR ALARM Operating manual TABLE OF CONTENTS Description and Operation Function GSM Thermo Sensor Detector Alarm Package Contents Technical Specifications GSM TSDA Structural Design External Temperature Sensor Structural Design Function and Operation of the GSM TSDA Set Up Preparing and Operating the GSM TSDA Configuring the GSM TSDA Accessing the Programming mode Setting up for the First Time Use Verifying set up Changing amp Adjusting the Parameters GSM TSDA Installation Troubleshooting the GSM THERMO Sensor Alarm Detector Contact Us Warranty NOOO EXPRESS 1 1 1 2 EXPRESS 1 Description and Operation Function The GSM THERMO Sensor Alarm Detector is designed to monitor temperature in a controlled environment and when pre set temperature thresholds are triggered in the monitored zone it will transmit an SMS ALARM notification and or place a call to your mobile telephone up to six 6 numbers The GSM TSDA is designed to monitor temperature in apartments homes country retreats steam rooms saunas garages basements vegetable storage units incubators refrigerators greenhouses automobiles outdoor facilities etc it can also be used to monitor devices
3. Package Contents Include in accordance with Table 1 Table 1 Contents Description Quantity GSM Thermo Sensor Detector Alarm 1 one Lithium CR123A 3V battery 1 one External temperature Sensor DS18B20 1 one cable L 1 5m jack 2 5mm User s Manual 1 one 5 1 9 1 4 Technical Specifications in accordance with Table 2 Table 2 Primary Technical Specifications DESCRIPTION VALUE Max Number of telephones notified 6 six Time lapse for notification 20 40 seconds GSM Module Operating Standards GSM 800 900 1800 1900 Detector temperature operating range from 10 to 50 C Temperature measuring range of the Built in Sensor limited to temp operating Range of the GSM TSDA from 10 to 50 C Temperature measuring range of the External temperature Sensor from 40 to 99 C Battery type 1x CR123A 3 V Uninterrupted operating life span using one battery at a temperature of 25 C up to 12 months Enclosure durability level IP40 Relative operating humidity 35 C condensation not to exceed 93 GSM TSDA size amp dimensions do not exceed 109x32x27 5 mm GSM TSDA w battery weight 60 9 does not exceed Temperature Sensor cable length 1 5m EXPRESS Please Note The GSM TSDA can operate at a temperature of 25 C but the operating battery life span and quantity of S
4. 2 Remove SIM card amp re battery the GSM LED installed install as shown in diag 7 flashes rapidly amp does not 3 SIM card is locked with 3 Disable the SIM card PIN code flash once 1 Every 4 four ja PIN code feature by using a GSM Telephone seconds as Required SIM see tel operating manual card is not Logging on to the 4 GSM network is 4 a Re locate the GSM TSDA to a network inaccessible location with good access to a GSM Network signal in accordance with item 2 7 in this user s manual b Change the mobile Network provider When verifying operation with 1 Faulty contact between the 1 Verify connection the Ext Temp Sensor the Temp Sensor jack and the GSM TSDA Does not enter GSM TSDA socket ALARM mode LED does not 2 Insufficient temp to 2 Create sufficient temp or reduce glow Red no Notifications Trigger threshold temp Threshold triggered EXPRESS 4 CONTACT US ALPHA ARSENAL LLC 104 20 Queens Blvd Ste 1B Forest Hills NY 11375 US T F 1 718 440 3281 1 718 355 9281 Skype alpha arsenal E mail info alpha safe com support alpha safe com Website www alpha safe com 5 Warranty Coverage The warranty period is one year from date of purchase During the Warranty period the manufacturer will repair exchange adjust or replace at its discretion any defective product This warranty does not cover damage resulting from any unauthorized attempts to rep
5. EXPRESS 2 High temperature detected Tn SNN 5 Low temperature detected Tn SNN Diag 5 ALARM Notifications 2 Tn normal SNN Diag 6 Auto Reset Notification Tn Temperature Sensor number T1 or T2 T1 Built in Temperature Sensor T2 External Temperature Sensor S indicates GSM network signal strength NN indicates GSM network signal strength as a percentage e g 55096 S75 etc The value indicating GSM network signal strength SNN is included in all SMS notifications except for notifications showing remaining SIM card balance 2 Set Up 2 1 Preparation of the GSM TSDA for Operation After opening the package visually inspect the GSM TSDA for any physical defects and to confirm all item parts are included Prior to operating the GSM TSDA disable the PIN number request feature on the SIM card with the assistance of a mobile telephone refer to mobile telephone user s manual Check and verify there is a sufficient balance on the SIM card 2 2 Configuring the GSM TSDA At initial power up the GSM TSDA records on to the SIM card the following parameters and values in accordance with Table 4 Table 4 GSM TSDA Settings Cell ae Et Description Available Values 1st telephone 1 sms 000 number primary for R SE mat notification 2 2sms 000 3 3sms 000 Telephone numbers Enter number in the following format 4 4sms 000 for notification 1 9 417180000000 5 5
6. the call and emit 1 one audible confirmation beep This number will be recorded in cell 1 1SMS see table 4 as the designated primary number and will send an SMS notification from the GSM TSDA indicating Setting Reset Number Added 1XxXXXXXXXXX 2 5 2 6 EXPRESS 3 Proceed to record any additional notification telephone numbers by calling from each of them and after each additional number is recorded an SMS notification is sent to the primary telephone number containing Number Added 12zzzzzzzzz Number Added 12zzzzzzzzz etc 4 One 1 minute after the last call is received the GSM TSDA will transmit an SMS containing the settings see diag 8 to the primary telephone number and will then enter Armed On Guard mode If you were unable to record all the necessary additional notification telephone numbers either re insert in the Protective Plastic Insert between the battery and contacts or remove the battery wait 2 two minutes and then repeat the procedure from the beginning see item 2 6 Received from 1 YYYYYYYYYY 1 47XXXXXXXXXX 7 100 14 7 18 1 28 40 29 10 36 1 38 40 39 10 SNN 1 Primary notification number 14 Frequency of test status Notifications 18 Alarm notification option 28 Upper Temp Threshold 2 29 Lower Temp Threshold 2 Signal Strength GSM TSDA number 7 Balance Inquiry 28 Upper Temp Threshold 1 29 Lower Temp Threshold 1 36 Notification language Diag
7. 8 Sample SMS with Settings Verifying Set up 1 Attach the external Temperature Sensor by inserting the jack into the GSM TSDA XS4 socket 2 Place the Temperature Sensor in location where the temperature exceeds 40 degrees Celsius e g place under a hot lamp 3 Within a few seconds the GSM TSDA LED indicator will glow Red and will trigger into ALARM mode afterwards place the Temp Sensor in normal conditions by removing it from under the hot lamp 4 Wait to receive an SMS notification containing the text High Temperature Detected T2 and an incoming telephone call from the Alarm Detector acknowledge by disconnecting the incoming call After the concluding the notifications the LED indicator will turn off and the GSM TSDA will enter Standby mode 5 After the Temperature Sensor cools off temperature falls below 38 C the GSM TSDA automatically resets and enters Armed On Guard mode Wait to receive an SMS showing T2 Normal Changing the Parameter Value Settings Value parameter settings are installed during the 15 first power up and can later be changed The parameter values can be changed using the following methods Method 1 The GSM TSDA settings can be configured by using the Online Service located at service alpha safe com by utilizing the Express GSM Configurator for Android or iOS or by using the application for central monitoring GSM Panel available for download from play g
8. MS s sent will be reduced GSM TSDA Structural Design The GSM TSDA unit consists of a cover body with a LED indicator and a base diag 1 amp 2 The cover body has an opening with pop out plug to connect the external Temperature Sensor diag 2 Inside the cover body mounted on the base is the controller circuit board to which the GSM module is attached diag 3 The circuit board and cover body attach to the base unit using clips The cover body and base unit are made of ABS plastic LED indicator Cover body p gt 1 5 EXPRESS Diagram 1 GSM TSDA design General view Top view Cover body Bottom view Mounting holes Diagram 2 GSM TSDA Design Top amp bottom view The controller circuit board refer to diagram 3 contains a battery holder GB1 audio indicator BQ1 two color LED indicators VD1 and a socket XS4 in order to connect a Temperature Sensor The two color LED indicates the state of the GSM TSDA in accordance with table 3 The GSM module circuit board contains a SIM cardholder XS3 and a GSM LED to indicate network signal strength Diagram 3 Exposed view of the controller circuit board and GSM module The GSM TSDA is shipped with an installed battery insulated from the contacts by a protective plastic insert refer to diagram 7 External Temperature Sensor Design The external Temperature Sensor is functionally identical to the built in Temperature Sensor BK1 The external Tempe
9. air or from any use not in accordance with the instruction manual The warranty does not cover physical damage of any kind whatsoever nor does it cover damage caused by any attempt to tamper with or disassemble the product The warranty coverage does not extend to the batteries The warranty period commences on the day first purchased from the manufacturer or an authorized reseller as evidenced by a purchase receipt Without a valid purchase receipt the manufacturer is relieved of its obligation to provide warranty service LPHA ARSENAL ALPHA ARSENAL ALPHA ARSENAL ALPHA ARSENAL ALPHA ARSENAL ALPHA AR BEST SOLUTION FOR SAFETY OF YOUR HOME ts E mail nfo alpha s ao vw alpha safe cor iOS or Android
10. d mode While in Armed On Guard mode and when the pre set temperature thresholds low or high are violated the GSM TSDA will enter ALARM mode and will then execute notifications via SMS and or by placing outgoing calls After concluding ALARM notifications the GSM TSDA enters Stand By mode While in Stand By mode sensing no violations when the temperature returns to within 2 degreesof the pre set temperature low or high thresholds the GSM TSDA automatically resets to Armed On Guard modeand transmits an SMS Diag 6 to the primaryNotification telephone number The GSM TSDA is Disarmed by interrupting the power source by either replacing the protective plastic battery insert or by removing the battery 8 EXPRESS 1 6 4 GSM TSDA Indicators The GSM TSDA has built in LED and sound indicators In addition the GSM LED indicates GSM signal strength Indicator descriptions can be found in Table 3 Table 3 GSM TSDA Indicators GSM LED Event Mode LED Indicator Sound Indicator indicator Power On Glows Red Glows Red 3 Sec GSM Network Search Glows Red Flashes for 20 40 Sec GSM Network Activation At Start up Flashes Red Green 3 Beeps Once every 4sec Programming Mode Glows Green GSM TSDA Incoming Call or SMS a Audio Beep Armed On Guard Mode Alarm Mode High Temp Threshold Glows Red Aani Glows Green
11. e In order to access Programing mode consecutively execute the following actions 1 Install the SIM card as shown in diag 7 Caution Prior to installing or removing the SIM card it is necessary to de activate the GSM TSDA electrical supply i e install the protective plastic battery insert or remove the battery 2 Remove the Protective Plastic battery Insert from in between the contacts and the battery see diag 7 or install a battery using correct polarity if previously removed 2 4 EXPRESS Removing the Protective Plastic battery Insert Power SIM Card Source SIMCard Installation T Protective Plastic Insert Diag 7 SIM card installation protective plastic battery insert removal 3 The GSM TSDA LED indicator will glow red The GSM LED will glow for 3 seconds and will begin to flash quickly 4 Wait for the SIM card to register on to the GSM network At the conclusion of registration 3 beeps will be heard and the GSM LED will flash 1 once every 4 four seconds The GSM TSDA LED indicator will glow green This indicates that the GSM TSDA has entered Programing mode During the entire duration of the Programing mode the LED indicator will glow green In the event the GSM LED continues to flash quickly the SIM card is not registering on the GSM network and might be due to the SIM card being incorrectly or not installed blocked by a PIN code or the GSM network
12. emoving the cover and the circuit board from the base Attach the base using two screws then snap in the circuit board and then replace the cover Double sided tape can be used to mount the GSM TSDA on to a properly prepared surface 4 Connect the Temperature Sensor to the GSM TSDA Prior to making the connection it is necessary to break out the plastic plugs from the connection opening 5 Verify operation in accordance with item 2 5 6 Install the external Temperature Sensor at a location where temperature needs to be monitored bearing in mind that the external Temperature Sensor is enclosed inside a metal casing see diag 10 7 Run the Temperature sensor connection cable in a manner that does not interfere with moving about the monitored location Sensitive Operating Surface Of the external Temperature Sensor metal enclosure Diag 10 Sensitive Operating Surface of the external Temperature Sensor 3 Troubleshooting the GSM TSDA Table 5 Troubleshooting Guide Description of Symptom Possible Cause Solution No Audio beeps or GSM 1 Battery improperly 1 Remove the battery amp re install LED flashes in the GSM installed properly using proper polarity TSDA after the Battery is 2 Battery is discharged 2 Install a new fresh Battery installed CR123A 3V After powering up the GSM 5 card is not installed 1 Verify the presence of a SIM card TSDA detector inserting the 2 SIM card is incorrectly
13. is inaccessible take steps in accordance with table 5 Upon entering Programing mode the GSM TSDA sends an SMS notification with settings to the primary notification telephone number if the primary number was previously recorded in the SIM card memory For the span of 1 one minute the GSM TSDA remains in Programing mode and stands by for an incoming call and or SMS containing any changes to the settings In the absence of an incoming call SMS the GSM TSDA at the expiration of 1 one minute enters Armed On Guard mode In the event of an incoming call SMS occurring and being accepted the GSM TSDA at the expiration of 1 one minute will enter Armed On Guard mode and will transmit an SMS notification reflecting the setting changes to the primary registered telephone number Setting up for the First Time After powering up the GSM TSDA a template with cells containing default values will be created in the SIM card phone book in accordance with table 4 Later on you are able to edit and alter these parameters and values It is necessary to record notification telephone numbers to the SIM card memory Perform the followings steps consecutively 1 Access Programing mode in the device see item 2 3 2 Begin by calling the GSM TSDA SIM card telephone number from the telephone number that will be used as the primary notification number After receiving and recording the number the GSM TSDA will disconnect
14. k select 1SMS then select change erase the old number and record the new primary notification telephone number etc Note Some mobile telephone models do not support this function In addition to the change parameter methods listed above adding deleting notification telephone numbers can also be accomplished via a telephone call from the primary notification telephone number to the GSM TSDA while in Programing mode After calling from the primary notification telephone number all telephone numbers contained in the SIM card memory are erased and it will be necessary to re add all required telephone numbers all over again Attention This action resets all settings to the default settings as shown in Table 4 GSM TSDA Installation The GSM TSDA should be installed at a location that will be shielded from atmospheric elements physical damage and access by unauthorized persons and will have access to a reliable GSM signal The GSM TSDA should be located away from high power electrical cables In order to install the GSM TSDA consecutively execute the following steps 1 Select a location to install the GSM TSDA bearing in mind that the Temperature Sensor connection cable is 1 5 meters in length 2 Mark up the selected installation location bearing in mind measurements and the location of mounting holes as located on the GSM TSDA base Diag 9 Installation Size Specifications EXPRESS 3 Install the GSM TSDA by r
15. oogle com search Express GSM or GSM Panel The created configuration will be sent to the GSM TSDA SIM card 2 7 EXPRESS Method 2 1 Using the primary notification telephone create an SMS message using values in accordance with table 4 For example in order to change the notification method it is necessary to send an SMS message containing the following text Characters are entered without quote marks and spaces 18 0 where 18 indicates the cell number and 0 indicates the selectedparameter value In order to change several parameters at once it is necessary to list the parameters separating them with a comma For example 2 1Xxxxxxxxxxx 18 3 28 25 29 15 36 1 38 95 39 30 etc Note Characters are entered without quote marks and spaces 2 Access Programing mode in the GSM TSDA item 2 3 3 Send a previously prepared SMS message to the GSM TSDA telephone SIM card number 4 Wait to receive an SMS notification confirming the selected parameter values Method 3 It is possible to change and configure the parameter values directly with the aid of a GSM mobile telephone In order to accomplish this install the GSM TSDA SIM card into any GSM mobile telephone To access the necessary parameter open the telephone book select the cell to be altered and make the necessary changes in accordance with table 4 For example in order to change the primary notification telephone number in the telephone boo
16. placed and located near the Thermo Sensor such as radiators hot water heating system pipes heated floors etc The GSM TSDA supports the following operational modes Programming Armed On Guard Alarm Standby GSM THERMO Sensor Detector Alarm FEATURES Installs at any location with mobile GSM reception Automatically resets to Armed On Guard mode after a triggered Alarm The GSM TSDA is capable of monitoring temperature using the built in or the external Thermo Sensor as well as by using two external Thermo Sensors simultaneously Arms and Disarms by simply turning power on or off Settings programmable via mobile telephone online and thru utilizing Configurator Express GSM Android iOS apps and the GSM Central Control Monitoring Panel Uses two notification languages English and Russian Operates on a single 3 volt CR123 lithium battery for up to 12 months Automatically identifies remaining SIM card balance inquiry telephone number The external Temperature Sensor is activated or de activated by connecting or dis connecting the external Temperature Sensor cable jack into or out of the Detector Alarm socket The built in Temperature Sensor can be dis abled by setting unattainable temperature values cells No 28 amp 29 Table4 The GSM TSDA is designed to operate indoors or near the item to be monitored and to monitor around the clock 24 7 in stable non extreme and non explosive conditions
17. rature Sensor is enclosed in a metal casing to which a 1 5 meter cable with a 2 5 mm jack is attached see diag 4 EXPRESS Metal casing of the external Temperature Sensor a Diagram 4 External Temperature Sensor 1 6 Function and Operation of the GSM TSDA 1 6 1 Operational Principle of the GSM TSDA While in Armed On Guard mode when the set temperature thresholds are exceeded the GSM TSDA will receive an Alarm trigger signal from the Sensor enter ALARM mode and will then execute notifications 1 6 2 Primary Functions of the GSM TSDA The GSM TSDA executes the following functions Manages temperature in a monitored zone spot Transmits SMS notifications and or calls the list of notification telephone numbers up to six 6 numbers programmed into the GSM TSDA SIM card memory when an ALARM is triggered Automatically resets to Armed On Guard mode and transmits an SMS to the primary notification telephone number Automatically requests remaining GSM TSDA SIM card balance and transmits an SMS to the primary notification telephone number 1 6 3 Operational modes of the GSM TSDA Upon activating power by either removing the protective plastic insert from in between the battery and contacts or by inserting a battery the GSM TSDAwill discover and connect to a GSM network and then enter Programming mode One 1 minute after all the settings conclude the GSM TSDA enters Armed On Guar
18. sms 000 6 6sms 000 Remaining balance Auto detection of remaining balance tel 7 BALANS 0 Inquiry USSD number Manual entry tel e g 100 2 3 EXPRESS external Sensor Cell eae rn Description Available Values Sets frequency for test status SMS Frequency for test notifications Interval sets up to 250 days status SMS e g l TERI 1 notifications 1 Notification once a day 7 Notification once a week 0 Notification not sent 0 Only SMS to 1sms 6sms ne 1 Call SMS Alarm notification SMS sent to1sms then calls placed to all aS l oe during tel numbers followed by SMS transmittal to all remaining tel numbers 2sms 6sms 3 Only calls placed to 1sms 6sms Upper Temp 28 Tup1 40 Threshold for built in Increments of 1 degree C Sensor from 10 C to 50 C Lower Temp asterisk indicates minus 29 Tdowni x10 Threshold for built in plus not required Sensor N Template name 34 POLUS 3 w settings 3 For operation w Polus 35 Mnum 000 GSM Security Panel Tel Ne Alarm Sensor application 36 LANG 1 Notification 0 Ru Language 1 En Upper Temp 38 Tup2 40 Threshold for Increments of 1 degree C external Sensor from 10 C to 50 C Lower Temp asterisk indicates minus 39 Tdown2 x10 Threshold for plus not required Operating service data that creates template during GSM TSDA set up Accessing the Programing Mod
Download Pdf Manuals
Related Search
Related Contents
universidad instituto de geografia e or elaboração da carta de c Spalding M770134 User's Manual 2 - Sharp Lincoln Electric K2188-1 Use and Care Manual Produktkatalog Videotechnik 2010 - ViSiTec Video weekly testing regular maintenance what you need to Le projet de Service à l`AST 62-59 : mode d`emploi Samsung WD906U4SAGD Manuel de l'utilisateur MNPG06-03 (Man T-ONE Medi-Pro ENG) - I Copyright © All rights reserved.