1. a y i A B G D al E F G H Object Quantity Description 1 Omnik inverter 1 Wall mounting bracket 1 user manual 4 Screw ST6x50 4 Expansion tube 1 4 1 1 AC connector DC connector Screw M4 Ground terminal zo 7 m 9 o w gt unik BR JE E E 4 2 Product Appearance B e Front Poy A c D Object Description A Removable front cover LED Light Three Functional key Four ojojo LCD Display Bottom unik Kas ee Object Description DC switch Option B Plug connectors for DC input c AC output terminals connect to grid D Communication interface RS485 GPRS WiFi USB 4 3 Product Identification You can identify the inverter by the side nameplate Information such as serial number SN type of the inverter as well as inverter specifications are specified on the side name plate The name plate is on the middle part of the right side of the inverter housing And the following figure is the side name plate example as on Omniksol 5k TL2 3P Pmax 5150W Pnom 5000W Vmax 1000v Smax 5000VA Input Vnom esov Output Vnom anure 2301a000 V VMPPT Imax BBA Isc from 5060Hz 25 to 600 Power factor 0 90i 0 90e IP65 0utdoor x Overvoltage category
2. Figure 32 Models display interface d Inverter SN Inverter serial number information is shown as Figure 33 51 unik Bk JE E NEE Figure 33 Inverter SN interface 7 4 3 3 Curves interface Curve interface draws day power curve X axis represents time in 1 hour from the left the first is 1 00 to 2 00 and the far right represents the night 22 00 Y axis represents the power value the full scale means rated power as shown in Figure 34 Figure 34 Curves interface 52 unik BE 7 5 Ground Protective ground port position On the right side of the inverter has a protective earth hole users can link to ground Grounding screw has been attached to the machine when user is connecting to the ground first remove the screws then put terminal with grounding cable to fix to the machine support Grounding Cable use 5mm2 Crimping steps 1 Using wire strippers stripped suitable length of grounding cable insulation as shown in figure 4 3 Ea Pb Lo Li 2 3 jmm Note L2 is longer than LI about the length of 2 3mm as shown in figure 4 4 En TE Z 14 lt 15mm 53 unik Bk E E NEE 7 6 State Information State Display State information Waiting Initialization amp waiting Wait Reconnect s Reconnect Checking s Checking Normal Normal Normal state Ground Fault GFCI failure oversized leakage current Fac Fail
3. 2 5 4 6 mm 12 10 AWG type PV CZM 19100 Order No 32 6020 19100 ill 3 Open end spanner PV MS 1 set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD socket wrench insert to tighten Order No 32 6006 il 5 PV SSE AD4 socket wrench insert to secure PV SSE AD4 Order No 32 6026 29 unik BR E E E 30 E o ill 6 Test plug PV PST Order No 32 6028 1 7 Test plug PV A F 15 mm ill 8 Torque screwdriver A F 12 mm Cable preparation ill 9 Use 14 10AWG 2 5 6mm conductor as DC cable Dimension A 3 6mm b 2 5 6mm ill 10 Strip cable insulation L 6 7 5 mm Take care not to cut individual strands ill 11 Open the clamp K and hold Place the contact in the appropriate cross section range Turn the crimp lugs upwards Release the clamp K The contact is fixed ill 12 Press the pliers gently together until the crimp lugs are properly located within the crimping die unik i TE E E ill 13 Insert the stripped cable end until the insulation comes up against the crimp insert Completely close the crimping pliers ill 14 Visually check the crimp ill 15 Insert the crimped on contact into the insulator of the male or female coupler until it clicks into place Pull gently on the lead to check that the metal part is correctly engaged ill 16 Ins
4. The inverter total has three indicators running lights green Fault lights red and Communication lights yellow as shown in Figure 2 See Table 1 for specific meaning 33 unik Bk E E NEE Figure 2 Indicator Panel Table Indicator Description NO Name State Description F Communication flashing Data is being transmitted lights dark No data transmission light Inverter connects to grid B Running lights normal dark Inverter don t connect to grid light Malfunction C Fault lights dark The machine is not the fault 7 3 Button The inverter total has four buttons from the left followed by UP button DOWN button ESC button and ENTER button as shown in figure 3 A B c D I I Figure 3 Keypad 34 unik ie NEE 7 4 Display Display interface is shown as Figure 4 Among them red dashed box is a fixed display area the rest is menu display area Menu display area is in response to key operation while fixed display area does not support control of keypad B T YDE 4105 O00 anm 8 Figure 4 Display interface 7 4 1 Fixed display area Fixed display area is divided into seven by content contains Instant power display block Models and auxiliary information display block Generation display block Temperature and time display block PV connection information display block AC connection information display block and Communication display block Sequenti
5. AC Connection Type Plug in connector Plug in connector Plug in connector Max Efficiency 98 2 98 2 98 2 Euro Efficiency 972 97 4 97 5 MPPT Efficiency 99 9 99 9 99 9 u unik Bk JE E NEE DC Insulation Monitoring Yes DC Switch Optional Residual Current Monitoring miini Unit RCMU gr Gril monitoring and Protection ational Grid Monitoring with Anti Vex islanding Protection Class I According to IEC 62103 Overvoltage Category Safety Standard PV II Mains Ill According to IEC 62109 1 EN 62109 AS NZS 3100 EMC Standard EN 61000 6 1 EN 61000 6 2 EN 61000 6 3 EN 61000 6 4 EN 61000 3 2 EN 61000 3 Grid Standard Dimensions WxHxD VDE AR N4105 VDE 0126 1 1 G83 1 EN 50438 RD1699 CEI 0 21 AS4777 C10 C11 352x421x172 5mm Weight 22kg Environmental Protection Rating IP 65 According to IEC 60529 Cooling Concept Fan cooling Mounting Information Operating Temperature Range Wall bracket 20 C to 60 C derating above 45 C Relative Humidity 0 to 98 no condensation Max Altitude above sea level 2000m Noise Level lt 450B Isolation Type Transtormerless Display TFT Graphic Display Data Communication RS485 WiFi GPRS optional Interfaces Computer Communication S232 USB Standard Warranty 5 Years 5 25 years optional 12 u
6. Install the inverter in the vertical direction is recommended with a max 15 degrees backwards e For the convenience of checking the LCD display and possible maintenance activities please install the inverter at eye level e Please make sure the wall you selected is strong enough to handle the screws and bear the weight of the inverter e Ensure the device is properly fixed to the wall e It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction e The ambient temperature of installation site should be between 20 C and 60 C between 4 F and 140 F Make sure the ventilation of the installation spot not sufficient ventilation may reduce the performance of the electronic components inside the inverter and shorten the life of the inverter 5 3 Safety Clearance unik Ok E E NEE Observe the following minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle euit ame Direction Minimum clearance Above 30cm Below 40cm Sides 30 cm 5 4 Mounting Procedure 20 unik BR dB E E E 1 Mark 4 positions of the drill holes on the wall according to the paper installation position scale packed in the carton box A METEPTH Som X 2 according to the marks drill 4 holes in the wall Then place four expansion tubes in
7. Recycling and Disposal for proper treatments Without Transformer This inverter does not use transformer for the isolation function Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low Voltage and Electromagnetic Compatibility cac The inverter complies with the requirement No unauthorized perforations or modifications Any unauthorized perforations or modifications are strictly forbidden if any defect or damage device person is occurred Omnik shall not take any responsibility for it unik KR E E 3 Product Information 3 1 Overview Industrial Layout m e Effective Shield For DC AC Communication Connections unik BR E E E 3 2 Major Characteristics Omnik inverter has following characteristics which make Omnik inverter High Efficiency High Reliability High Cost Effective Ratio Wide DC input voltage and current ranges enables more PV panels connected e Wide MPP voltage range ensure high yield under various weather conditions e High MPP tracking accuracy ensure the minimum power loses during converting e Complete set of protection methods Also following protection methods are integrated in Omnik inverter Internal overvoltage e DC insulation monitoring e Ground fault protection e Grid monitoring e Gr
8. This device SHALL NOT be disposed of in residential waste 57 unik Bk E E NEE 10 Troubleshooting LCD display Possible actions Isolation Fault 1 Check the impedance between PV amp PV and the inverter is earthed The impedance must be greater than 2M9 2 Check whether the AC side has contacts with earth Ground Fault The ground current is too high 2 After cut off the AC side connection unplug the inputs from the PV generator and check the peripheral AC system 3 After the cause is cleared re plug the PV panel and AC connection and check PV Inverter status Grid Fault Fac Over Range Vac Over Range 1 Wait for a moment if the grid returns to normal PV Inverter automatically restarts Make sure grid voltage and frequency meet the specifications ne Resumable Fault eu 1 Grid is not connected 2 Check grid connection cables Utility Loss 3 Check grid usability If grid is ok and the problem persists maybe the fuse in the inverter is open please call service 1 The internal temperature is higher than specified normal value Over Temperature 5 Find a way to reduce the ambient temperature Or move the inverter to a cooler environment PV over Voltage Consistent Fault Disconnect PV or PV from the input restart the inverter Relay Check Fail DC INJ High Permanent 1 Disconnect ALL PV or PV Fault EEPROM R W F
9. the holes using a rubber hammer Next wring 4 screws into the expansion tubes So far the wall mounting bracket is fixed already 3 check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 screws in the wall and finally attach the inverter to the screws slightly 2 unik BR JE E E 5 5 Safety lock unik KR wR After the inverter is hang up on the bracket lock up the device and the bracket together at the Lower Right Corner of the inverter as the picture showed below Padlock Recommended padlock dimension Ab A Shackle Diameter 5 7 mm B G i B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger and secured lock cylinder Q NOTICE For further maintenance and possible repair please keep the key of the padlock in a safe place 23 unik Bd E E NEE 6 6 1 24 Electrical Connection Safety A DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on accidents prevention This inverter will be directly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations J NOTICE Electrical connections shall be carrie
10. HPF V1 0 unik 3 Fee 7773 Oyu EEE mv User Manual Installation Operation Omniksol 5k TL2 3P Omniksol 6k TL2 Omniksol 8k TL2 Omniksol 9k TL2 Omniksol 10k TL2 Omnik New Enety Co Ltd unik B Fee E Catalog Catalog 1 Notes on this manual 1 1 General notes 1 2 Symbols Used 1 3 Target Group 2 Preparation 2 1 Safety Instructions 2 2 Explanations of Symbols on Inverter 3 Product Information 3 1 Overview 3 2 Major Characteristics 3 3 Technical Data 4 Packing checklist 4 1 Assembly parts 4 2 Product Appearance 4 3 Product Identification Further Information 5 Installatior 5 1 5 2 5 3 5 4 5 5 6 1 6 2 6 3 6 4 7 Display and Operation zal 72 Safety Mounting Instructions Safety Clearance Mounting Procedure Safety lock Safety AC Side Connection DC Side Connectior Communication and Monitoring Device LCD Panel Indicator unik KEES 7 3 Button 7 4 Display 7 4 1 Fixed display area 7 4 2 Menu display area 7 5 Ground 7 6 State Information 10 Th 12 13 Monitoring system Recycling and Disposal Troubleshooting Warranty Abbreviation Contact unik Ok E E NEE 1 Notes on this manual 1 1 General notes The main purpose of this User
11. III Mains II PV S VDEO126 1 1 VDE AR N 4105 G59 2 AS4777 2 3 Ay RD1699 c10 11 EN50438 m CE ZBAAAG lOmin Further Information If you have any further questions concerning the type of accessories or installation please check our website www omnik solar com or contact our service hotline 5 Installation 5 1 Safety unik Fee NEE ih DANGER DANGER to life due to potential fire or electricity shock DO NOT install the inverter near any inflammable or explosive items This inverter will be directly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE NOTICE due to the inappropriate or the harmonized installation environment may jeopardize the life span o the inverter Installation directly expose under intensive sunshine is not recommended The installation site MUST have good ventilation condition 5 2 Mounting Instructions 18 J e Omnik inverter is designed for indoors and outdoors installation in order to extend the service life of inverter we suggest to install the inverter in the basement or garage or other regions without sun rain and snow Since the inverter generates noise at work so do not install it in the bedroom or often been active region e
12. ail 2 Wait for a few seconds SCI Failure AC HCT Fault GFCI Failure 3 After the LCD switches off reconnect and check again If the problems remain please call local service 58 unik KE ee 11 Warranty Dear Customer Thanks for choosing Omnik products The warranty period for inverter is 60 months as standard starting from the date of the purchase invoice date marked e Terms and Conditions Omnik offers 60 months from the date of purchase from retailer for Omniksol 13K TL2 Omniksol 15K TL2 Omniksol 17K TL2 Omniksol 20K TL2 on grid inverters subject to the conditions listed below Please note that this does not apply for the accessories If a product is suspected of being defective during the specified Omnik factory warranty period then Omnik will initially perform a pre qualification of the issue If a product is determined to be defective then Omnik will appoint a local installer who will conduct On site inspection amp repair or Exchange for same or similar replacement product In the latter case the remainder of the warranty entitlement will be transferred to the repaired or replacement product In such an event you do not receive a new certificate as your entitlement is documented at Omnik Exclusion of Liability Circumstances where warranty is not provided Inverter damaged during transportation installation usage connection non compliance with the instruction man
13. ally corresponds to A B C D E F and G blocks in figure 4 7 4 1 1 Instant power display block Instant power display block provides two display modes instant power values and percentage 7 4 1 2 Models and auxiliary information display block Type information rated power Fans logo indicates fan operation status 35 unik B E E E 7 4 1 3 Generation display block E total records the total generating capacity of the inverter E Today records the day generating capacity of inverter 7 4 1 4 Temperature and time display block Heat sink temperature is in the left side in the right side that is the internal temperature 7 4 1 5 PV connection information display block This mode provides the information of number of PV strings PV voltage and PV current 7 4 1 6 AC connection information display block This modes provides the information of grid single three phase grid voltage and grid current 7 4 1 7 Communication display block This modes provides the monitoring connection includes RS485 communication GPRS communication and WiFi communication 7 4 2 Menu display area Menu display area is divided to three display modes working state mode menu mode and curve mode through the UP button and DOWN key to switch the following sections will explain these three modes 7 4 2 1 work state interface This interface provides current work status current national safety regulation and grid frequency inf
14. an clearly monitor inverter s operating data It can also be configured with PMB s power management function Working principle of the system The omniksol inverter can be connected to the PMB Power Management Box via its RS485 interface the maximum of the quantity is 20 sets three phase inverter unik KREME Inside the PMB a web server is integrated in customers can view or check the detailed information about their inverter by login on a IP address of PMB for example http 192 168 16 48 index asp the information including but not limited to total quantity of the inverters gross generation generation for today as well as all the parameters of each inverter like voltage current and frequency etc Meanwhile the PMB can receive the signal from the local power grid via a Radio Ripple Control Receiver therefore to archive the active power reactive power compensation function for the inverter Recycling and Disposal To comply with European Directive 2002 96 EC on waste Electrical and Electronic Equipment and its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved collection and recycling facility in your area Ignoring this EU Directive may have severe affects on the environment and your health A WARNING X
15. d out in accordance with the applicable regulations such as conductor sections fuses PE connection NOTICE To ensure the safety of personnel and equipment needed to mount the PV array is connected and grounded with other conductor casing unik KBR 6 2 AC Side Connection A DANGER DANGER to life due to potential fire or electricity shock NEVER connect or disconnect the connectors under load 1 Integrated RCD and RCM The Omniksol inverter is equipped with integrated RCD Residual Current Protective Device and RCM Residual Current Operated Monitor The current sensor will detect the volume of the leakage current and compare it with the pre set value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assembly Instructions NOTICE Use 14 12AWG 2 4mm2 copper wire for all AC wiring connections to Omnik inverter Use only solid wire or stranded wire 1 Remove length y of N L 1 2 conductor 35mm 1 38 PE conductor 40mm 1 57 sheath of AC cable terminal length x about 14mm 0 55 of the inner wrapper then dress the conductor terminals with ferrules or tin soldering x 25 unik BR JE E E 2 Check that all parts of AC connector are present Then slide hex nut onto the cable and insert the cable end through clamp ring 3 Insert the stripped N L and PE conductor t
16. e date format is month day year shown in Figure 18 by UP and DOWN button can adjust month then press ENTER go to adjust Day Similarly adjust the year and finally press the ENTER button to finish the setup Figure 18 set date interface j set password k set Over voltage and frequency limit Over voltage and frequency have two pages over frequency PAGE 19 and under frequency page 20 and press the button up and down to set it over frequency setting 44 unik ie ee LE have four limitation data over frequency 1 over frequency 2 over frequency 3 over frequency 4 Press the button Enter to enter into the setting status and press the up and down to select the limitation data and press the enter to finish it Figure 20 set under frequency limit interface 1 set over voltage limit Over voltage setting is also divided to 2 pages overvoltage settings Figure 21 and under voltage setting Figure 22 The way to set up under frequency limit is the same with set over frequency limit 45 unik Bk E E NEE Figure 22 Set voltage limits interface m Set MPPT scan time MPPT scan setting interface is shown as Figure 23 by UP and DOWN button to adjust the hour then press ENTER adjust the minute and press ENTER button that setup is complete 46 unik i ee Figure 23 Set MPPT scan interface n protective item The inverter i
17. erminal to the appointed holes use a cross screwdriver to tighten it with tightening torque 1Nm 26 unik i JE E E 4 Insert the connector to clamp ring with two click sound and then tighten the hex nut with tightening torque 4Nm 5 Finally connect the straight plug to the AC terminal on inverter Pay attention to the polarity of the terminals to avoid wrong connecting 27 unik B Fee E 6 3 DC Side Connection 28 DANGER DANGER to life due to potential fire or electricity shock C NEVER connect or disconnect the connectors under load J amp NOTICE DC Switch Optional may be integrated or external to Inverter and it can be used to connect or disconnect the C DC source from Inverter Pe MC4 Assembly instructions E If during self assembly parts and tools other than those stated by MC are used or if the preparation and assembly instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed A For protection against electric shock PV connectors must be isolated from the power supply while being assembled or disassembled A The end product must provide protection from electric shock EF The use of PVC cables is not recommended 3 Unplugging under load PV plug connections must not be unplugged while under load They can be placed in a no load state by switching off the DC AC converter or breaking the DC c
18. ert the appropriate end of the test pin into the male or female coupler as far as it will go If the contact is correctly located the white mark on the test pin must still be visible ill 17 Screw up the cable gland hand tight with the tools PV MS or tighten the cable gland with the tools PV WZ AD GWD and PV SSE AD4 In both cases The tightening torque must be appropriate for the solar cables used Typical values are between 2 5 Nm and 3 Nm ill 18 Plug the parts of the cable coupler together until they click in place Check that they have engaged properly by pulling on the cable coupler 31 32 unik Bk E E NEE 6 4 Communication and Monitoring Device There are 2 RJ45 plugs in the bottom side of the Omnik inverter as the following figure ri Tif These 2 RJ45 plugs are used for multipoint communications that is up to 50 Omnik inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at the same time and maximum length of the cable is 1000m Through these plugs the user can get the data from these inverters and can also configure parameters of them 7 Display and Operation 7 1 LCD Panel The display panel composed of three parts lights display and buttons As shown in Figure 1 30 et OOO K 2316 38 L 2324 g3 12 ood 23 98 13 Figure 1 Display Panel 7 2 Indicator
19. ion Does not support this feature c Set Safety regulation and country Set safety regulation also needs the password authentication to be verified by entering the safety selection interface shown in Figure 14 the unit supports 43 types of 4 unik Bk E E NEE safety regulations VDE 4105 VDE 0126 Spain and so on through the UP key and ENTER key to scroll select and press ENTER key then setup is complete Figure 14 setting safety regulation interface d WiFireset WiFi reset is to reset the WiFi AP address as shown in Figure 15 select YES through UP and DOWN button then press ENTER operation is complete Figure 15 WiFi reset interface 42 unik i E E NEE e Clear generating capacity Clear generating capacity means clear total generating capacity E Total and clear day generating capacity E Today through the UP and DOWN button to select Yes as shown in Figure 16 then press ENTER the clear is complete BB 23 G34 5288 5286 Figure16 Clear generating capacity interface f set the firmware g set the price h settime Time format is hours minutes seconds shown in Figure 17 by UP and DOWN button to adjust the hour then press ENTER to adjust minutes Similarly adjust seconds and finally press the ENTER key to finish the setup 43 unik Bk E E NEE Figure17 setting time interface i set date Date Th
20. ircuit interrupter Plugging and unplugging while under voltage is permitted E It is unadvisable to use non tinned cables of type HO7RN F since with oxidized copper wires the contact resistances of the crimp connection may exceed the permitted limits E Disconnected connectors should be protected from dirt and water with sealing caps gt Plugged parts are watertight IP67 They cannot be used permanently under water Do not lay the MC PV connectors on the roof surface BSP See the MC catalogue 2 solar lines for technical data and assembled parts unik i E E NE PV Female cable coupler PV Male cable coupler Optional EB aa ES PV KBT4 PV KST4 PV SSH4 T17A 1 5mm 716AWG Protection class 22A 2 5mm 14AWG matediunmated PE7AP2X Rated current 55 4 4mm 6mm 10AW G 40 to 90 C IEC Ambient 40 to 75 C UL Rated voltage 1000V DC IEC temperature range 40 70 C 9 1000V DC UL UL 14AWG Upper limiting 05x EC Safety class Il temperature Note The DC connector Is MIC4 type you can order the specified tools at MC website http www multi contact com ill 1 Stripping pliers PV AZM incl built in blade as well as hexagonal screwdriver A F 2 5mm Cable cross section 1 5 2 5 4 6 mm type PV AZM 1 5 6 Order No 32 6029 156 ill 2 Crimping tool incl locator and built in crimping insert PV CZM Crimping range
21. lishing suitability for VDE 0126 1 1 Grid Connection of the Inverter Switch in the DC Circuit Disconnects DC source DC Switch from Inverter May be integrated or external to Inverter unik Knee 13 Contact Suzhou Headquarter Xinghu Road No 218 bioBAY Park C2 101 215123 Suzhou China Tel 86 512 6295 6676 Fax 86 512 6295 6682 Email info omnik solar com www omnik solar com Omnik German Service Center A der Pikardie 6 01277 Dresden Deutschland Tel 49 0 351 30986031 Fax 49 0 351 30930022 Email service de omnik solar com Service line Tel 86 512 6295 6676 Fax 86 512 6295 6682 Email service omnik solar com 61
22. n Chapter 5 Installation e Chapter 5 and Chapter 6 are only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter unik EMG ee E amp NOTICE Hereby qualified personnel means he she has the valid license from the local authority in Installing electrical equipment and PV power systems up to 1000 V Applying all applicable installation codes Analyzing and reducing the hazards involved in performing electrical work Selecting and using Personal Protective Equipment PPE 2 Preparation 2 1 Safety Instructions DANGER DANGER due to electrical shock and high voltage DO NOT touch the operating component of the inverter it might result in burning or death TO prevent risk of electric shock during installation and maintenance please make sure that all AC and DC terminals are plugged out DO NOT stay close to the instruments while there is severe weather conditions including storm lighting etc unik KEE he A WARNING N The installation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to get the information of authorized repair facility for any maintenance or repairmen Any unauthorized actions including modification of product functionality of any form will affect the
23. ng integrated Unit RCMU Grid monitoring and protection Optional Electrical fuse protection Yes Protection Class I According to IEC 62103 Overvoltage Category Safety Standard PV II Mains Ill According to IEC 62109 1 EN 62109 AS NZS 3100 EMG Standard EN 61000 6 1 EN 61000 6 2 EN 61000 6 3 EN 61000 6 4 EN 61000 3 61000 3 3 Grid Standard Dimensions WxHxD VDE AR N4105 VDE 0126 1 1 G83 1 EN 50438 RD1699 CEI 0 21 AS4777 C10 G11 352x421x172 5mm Operating Temperature Range Weight 22kg Environmental Protection Rating 1P 65 According IEC 60529 Cooling Concept Fan cooling Mounting Information Wall bracket 20 C to 60 C above 45 C Relative Humidity 0 to 98 no condensation Max Altitude above sea level Noise Level Isolation Type Display 3 Data Communication Interfaces RS485 WiFi GPRS Wi Computer Communication RS232 USB Standard Warranty F ATi 5 25 4F 1 Mppt can reach rated Power for Omniksol 5k TL2 3P The AC voltage and frequency range depend on countries 14 unik Kas he 4 4 1 Packing checklist Assembly parts After you receive the Omnik inverter please check if there is any damage on the carton and then check the inside completeness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing fl j
24. nik i ee NEE Max PV Power 9000W 10000W Max DC Voltage 1000V 1000V Nominal DC Voltage 640V 640V Operating MPPT Voltage Range 150 800V 150 800V MPP voltage range at full load 380 800V 380 800V Start up DC Voltage 250V 250V Turn off DC Voltage 150V 150V Max DC Current A B 14A114A 14A114A Max Short Circuit Gurent or Z0A20A Z0AJ20A Number of MPP trackers 2 2 masdmum Taput power of Each r So Number of MPP trackers A 2 B 2 A 2 B 2 DC Connection Type MC4 connector MG4 connector a Max AC Apparent Power 8100VA 8200VA Nominal AC Power 8100W 8200W 3 N PE 220 380V SINIPE 220 380V Nominal AC Voltage 3 N PE 230 400V 3 N PE 230 400V 3 N PE 240 415V 3 N PE 240 415V Nominal Grid Frequency 50Hz 60Hz 50Hz 60Hz Max AG Current 13 8A 13 9A Grid Voltage Range 185 276V 185 276V Grid Frequency Range 45 55H2 55 65Hz 45 55H2 55 65Hz Power Factor 0 8 capacitive 0 8 inductive 0 8 capacitive 0 8 inductive Total Harmonic Distortion THD lt 2 lt 2 Feed in Starting Power 30W 30W Night time Power Consumption lt w lt w Standby Consumption lt 10W lt 10W AG Connection Type Plug in connector Plug in connector SS ee Max Efficiency 98 2 98 2 Euro Efficiency 97 5 97 5 MPPT Efficiency 99 9 99 9 13 unik Ok E E NEE DC Insulation Monitoring Yes DC Switch Optional Residual Current Monitori
25. ormation of current inverter as shown in figure 5 36 unik BE E NEE k KAN K YDE 4105 Eau A 50 01Hz tan nn nnn Ut ULI BL LIDI e 99 L2 EE 5251 6L 214 aad j 526 wg Aa a ts Figure 5 work state interface State Description wait Initialization waiting for the grid run Inverter has been connected to grid and is running normally fault Inverter malfunctions upgrade inverter is upgrading process 7 4 2 2 Menu interface The menu structure is the hierarchical consists of fault configuration and equipment as shown in figure 6 each main menu consists of several sub menu items on the left of vertical line is main menu item the right is submenu item corresponds to main menu item Select the main menu item by UP button and DOWN button and then enter a sub menu item through ENTER button 37 unik Bk E E NEE Figure 6 menu interface 1 Failure items Failure item is consist of three sub menu items clear current and history as shown in Figure 10 a Clear fault history System only can record at most 10 pes of fault information stored in the history menu To clear the fault history need password authentication as shown in figure 7 The factory password is 000000 users can change a single password by UP and DOWN button and then set the next digit password by ENTER button until six correct password is entered then pres
26. ound fault current monitoring e DC current monitoring e Integrated DC switch Optional unik LLELLE 3 3 Technical Data Max PV Power 5150W 6150W 8200W Max DC Voltage 7000V 7000V 7000V Nominal DC Voltage 640V 640V 640V Operating MPET voltage 150 800V 150 800V 150 800V Range CEMAS 260 800V 280 800V 360 800V Start up DC Voltage 250V 250V 250V Tum off DC Voltage 150V 150V 150V Max DG Current A B TIATIA TATTA TANT4A Max Short Circuit Current Max chot oia 16A 16A 16A 16A 20A 20A Number of MPP trackers 2 2 2 maximum Input power of on 5150w 4000w 5000w Number of DC Connection A2B2 A2B2 A2 B 2 DC Connection Type MGA connector MGA connector MGA connector Max AC Apparent Power 5000VA 6000VA 8000VA Nominal AC Power 5000W 6000W 8000W SNIPE 220 3807 SINIPE 220 3807 SNIPE 220 3800 Nominal AC Voltage 3INIPE 230 400V 3INIPE 230 400V 3 N PE 230 400V SINIPE 240 415V SIN PE 240 415V SIN PE 240 415V Nominal Grid Frequency 50H2 60Hz 50H2 60Hz 50H2 60Hz Max AC Current 88A 107A 136A Grid Voltage Range 185 276V 185 276V 185 276V Grid Freguency Range 45 55H2765 65H2 45 55H2155 65H2 45 55Hz 55 65Hz 0 8 capacitive 0 8 0 8 capacitive 0 8 0 8 capaciive 08 Power Factor inductive inductive inductive Total Harmonie Distortion 2 Rey 2 2 2 Feed in Starting Power 30wW 30W 30W Night time Power ai Zw SW Consumption Standby Consumption AW z10W z10w
27. s ENTER button can enter to clear fault interface as shown in Figure 8 Figure 7 Password authentication interface 38 unik i ee NEE Figure 8 Clear fault interface Choose YES button through UP and DOWN button then press ENTER button already clear the history fault information b Current fault information Current fault information records current fault code and content shown in Figure 10 If there is no fault then it will show no fault record Figure 9 Current fault record interface 39 OMNI Bk E E NEE Figure 10 Current fault record interface c History fault information This page provides the history fault record through UP and DOWN button to scroll up the records at most can display 10pcs of history fault information Every page will show single fault time fault code and fault content shown in Figure 11 Figure 11 History fault information interface 2 Setting item Setting menu is consist of fourteen sub items contains language setting communication safety regulation WiFi and so on shown in Figure 12 40 unik BE E NEE Figure 12 Setting item display interface a Language setting The inverter supports three languages Chinese English and Deutsch Select the language through UP and DOWN button then the set up is finished shown in Figure 13 Figure 13 Setting language interface b Set communicat
28. s Manual is to provide instructions and detailed procedures for installing operating maintaining and troubleshooting the following three types of Omnik New Energy Solar Inverters e Omniksol 5k TL2 3P e Omniksol 6k TL2 e Omniksol 8k TL2 e Omniksol 9k TL2 e Omniksol 10k TL2 Please keep this user manual all time available in case of emergency 1 2 Symbols Used A DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury a gt A WARNING WARNING indicates a hazardous situation which if not avoided can result in death or serious injury or moderate injury unik BE A CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury or moderate injury 1 NOTICE NOTICE indicates a situation that can result in property damage if not avoided A 1 3 Target Group Chapter 1 2 3 4 7 8 9 10 and Chapter 11 are intended for anyone who is intended to use Omnik Grid Tie Solar Inverter Before any further action the operators must first read all safety regulations and be aware of the potential danger to operate high voltage devices Operators must also have a complete understanding of this device s features and functions M WARNING Do not use this product unless it has been successfully installed by qualified personnel in accordance with the instructions i
29. s consist of 11pcs of protection items ISO GFCI DCI and so on user can turn on or off by themselves as shown in Figure 24 through UP and DOWN button can scroll up to view the state of protected item To reset a protected item need to press ENTER to go to the setup mode as shown in Figure 25 Figure 24 Set protection item interface In setting state through UP and DOWN button to turn on or off then press ENTER button to confirm and enter to set up the next protection item state until finish all the setup through ESC button to exit settings page 47 unik Bk E E NEE Figure 25 Set interface protection items 3 Equipment items Equipment menu is consists of four sub menus version WiFi model and serial number as shown in Figure 26 BBY oy 048 Figure 26 Equipment items Interface a Version NO The version number menu is consist of three sub menu the main CPU version number page Vice CPU version page CPU version number displayed page through UP and DOWN to scroll to view shown as figure 27 figure 28 and figure 29 48 unik BE E EE Figure 27 main CPU version interface Figure 28 Vice CPU interface version 49 unik B Fe E NEE b 50 Figure 29 display CPU version interface WiFi SN and add Figure 30 WiFi SN interface unik i E E NEE 131 WiFi AP add interface c Type of inverter Model information is shown in Figure 32
30. ual or other man made damage Operate the products beyond the applicable safety regulations The warranty card has been altered or its date is hard to recognize Change modification of repair attempts of the product without authorization Product description nonconformity from the content of warranty card Information on the original nameplate missing or not clear enough to identify the delivery date and product model Use non designed accessories Improper PV system design Force majeure e g lightening earthquake flood or fire Cosmetic changes to the unit from environmental conditions or accidents From the day the inverter is purchased please correctly fill in the Warranty Card and submit to the appointed installers to sign stamp and date Any changes need to be made by the appointed installers Please keep good custody of your Warranty Card and present it when you need the warranty service and keep the record provided by the service staff 59 unik Bk E E NEE 12 Abbreviation 60 LCD Liguid Crystal Display LED Light Emitting Diode MPPT Maximum Power Point Tracking PV Photovoltaic Vde Voltage at the DC side Vac Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point Alternating Current Form of electricity supplied by AC ah Utility Company Direct Current Form of electricity generated by DC PV modules German standard for estab
31. ure Grid frequency failure Fault Vac Failure Grid voltage failure Utility Loss No Utility amp Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal 54 unik BE E NEE Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC injection too high EEPROM RW Fail EEPROM problem SCI Failure Serial communication interface failure AC HCT Failure Output AC sensor abnormal GFCI Failure GFCI testing device abnormal Flash F W Updating Update About the further information for each fault please reference to Chapter 10 Troubleshooting 55 unik i ee E 8 56 Monitoring system Lavi b ff Castrol Receiver Inv n System configuration The system consists of Grid Radio Ripple Control receiver PMB Inverter Battery pack and so on view picture above for reference Introduction of sub element 1 PMB Power Management Box is core of the system It s used for managing power and monitoring working status of inverter 2 Radio Ripple Control Receiver receives managing instruction of power from grid operations and output digital switch amount to PMB Then PMB work on the output and send managing instruction of power to inverter 3 IE Firefox is a web browser for PC through which people can check PMB s built in webpage The webpage c
32. validation of warranty service Omnik may deny the obligation of warranty service K accordingly NOTICE Public utility only The PV inverter designed to feed AC power directly into the public utility power grid do not connect AC output of the device to any private AC equipment A CAUTION The PV inverter will become hot during operation please don t touch the heat sink or peripheral surface during or shortly after operation Risk of damage due to improper modifications Never modify or manipulate the inverter or other components of the system 2 2 Explanations of Symbols on Inverter KA E73 unik Bk E E NEE Dangerous electrical voltage This device is directly connected to public grid thus all work to the inverter shall only be carried out by qualified personnel 10min DANGER to life due to high electrical voltage There might be residual currents in inverter because of large capacitors Wait 10 MINUTES before you remove the front lid NOTICE danger This device directly connected with electricity generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating An error has occurred Please go to Chapter 10 Trouble Shooting to remedy the error This device SHALL NOT be disposed of in residential waste Please go to Chapter 9