Home
        MB150 User Manual
         Contents
1.       p    Cardinal  DETECTO       Model MB150  Mother Baby Scale    User Manual          CARDINAL SCALE MFG  CO     8535 M212 O1 Rev B PO BOX 151    WEBB CITY  MO 64870  03 15 PH  417  673 4631 e FAX  417  673 5001  www detectoscale com    Technical Support  Ph  866 254 8261 e techsupport cardet com    TABLE OF CONTENTS  INTRODUCTION onanan nananana eeaeee een    SPECIFIGAMONS ii a av ede eb Dein  BABY TRAY INSTALLATION cuco a ad  AGPOWERADAPTOR 23 55  15 34 Renee  INSTALLING REPLACING THE                                          IE PONG TIONS ca SEE Eee ernennen en  DISPLAY ANNUNCIATORS ooo   LEVEILINDIGATOR  3 222232448 82 42 22H 1 a Shee Bir  WEIGHT UNIESWITER  airport Pope              HOW      USE BMI FEATURE                                   SETTING THE AUTO OFF TIME             leeren    ERROR EE    8535 M212 O1 Rev B    MB150    FCC COMPLIANCE STATEMENT    WARNING  This equipment generates uses and can radiate radio frequency and if not  installed and used in accordance with the instruction manual  may cause interference to radio  communications  It has been tested and found to comply with the limits for a Class A  computing device pursuant to Subpart J of Part 15 of FCC rules  which are designed to provide  reasonable protection against such interference when operated in a commercial environment   Operation of this equipment in a residential area may cause interference in which case the  user will be responsible to take whatever measures necessary to correct the int
2.  body fat     6  Hold This annunciator will be turned on and Hat d be shown on the display for a few  seconds to indicate that the weight from the last weighing operation is being  held and the baby  child or adult can be removed from the scale  This feature  is useful if the baby or child is very active     7   gt 0    This annunciator is on the side of the display  An arrow will be turned on to  indicate the weight is at zero and the scale is ready to use     8  Net        annunciator is on the side of the display  An arrow will be turned on to  show that the weight displayed is net weight  Net weight is determined by  zeroing the weight of an item from the scale such as protective paper  blankets   pads or toys  This insures that only the baby or adult s weight is displayed     kg The kg annunciator is turned on to indicate the weight shown is in kilograms     Ib The Ib annunciator is turned on to indicate the weight shown is in pounds     LEVEL INDICATOR    9  Level The level indicator is located to the side of the  Indicator display  If the scale is not level  bubble will not be  centered   adjust mounting feet as required to center  bubble and attain a level scale        Not Level Level    WEIGHT UNIT SWITCH    The Weight Unit Switch is located on the lower front right of the scale next to the AC power  adapter jack  It allows to operator to easily change the weight units from pound to kilograms or  kilograms to pounds        Mounting Foot    AC Power Weight Unit  Adapt
3. E BATTERIES    The scale use six  AA  alkaline batteries  not included   You must first obtain and install  batteries before operations can begin  Batteries are contained in a battery holder inside the  scale  Access is via a removable panel on the bottom of the scale    1  Turn the scale over so that the display is 7  facing down        2  Locate the rectangular panel on the bottom of  the scale     3  To install or replace the batteries  first remove  the battery holder cover by pushing in on the  tab and lifting it up     4  If installing new batteries  proceed to step 5   If replacing the batteries  remove all 6 batteries  from the battery holder and then proceed to  step 5     5  Install the 6 new  AA  batteries in the battery holder  noting the polarity markings located in  the battery holder     6  After placing all 6 batteries in the holder   replace the battery cover     T  Turn the scale over  display facing up  and  press the On Off key     8  If the scale turns on  the batteries have been  installed correctly  If not  remove the panel  and check for one or more improperly  positioned batteries     9  The scale is now ready for normal weighing  operations     8535 M212 O1 Rev B    MB150 5    KEY FUNCTIONS    3 mr    qi Z O x al o              x BY OSL    Ayoede  5              INg   PIOH   f NY          Capaclty         j S 20 kg x 0 01 kg  Hold 44 Ib x 0 02 Ib    B    y DETECTO         2 www detecto com            Weigh   Baby Mode      NEVER leave      infant  ch
4. d  press the Tare key    The display will change to A  UFF    Press the Hold or Hold BMI key  The display will change to End    Press the Tare key  The scale will reset     The scale is ready for normal weighing operations     T IMPORTANT  The Auto Off feature ONLY works when the    scale is powered by the six  AA  batteries        8535 M212 O1 Rev B    MB150    ERROR MESSAGES    Low Battery   This message indicates that the battery should be  replaced soon  If the battery voltage drops too low   continued use with a low battery can affect weighing  accuracy  Remove the old battery and replace with a  new battery for operation     Over Load   The load is over the scale capacity  Reduce the load  and try again  If the trouble still exists  please call  your scale service representative     Over Zero   The load is over the limit the scale can zero when  powering on  Reduce the load and try again  If the  trouble still exists  please call your scale service  representative     Under Zero   The load is under the limit when powering on  Power  OFF scale and try again  If the trouble still exists  call  your scale service representative     8535 M212 O1 Rev B    MB150                00000    mm  um    
5. er Jack Switch    8535 M212 O1 Rev B    MB150 H     gt       m    O         p    11     1     2      4  5  6   7  8  9    10     HOW TO USE THE BMI FEATURE    Press the Adult mode On Off button   Make sure the display is showing DUU If not  press the Tare key   Press and hold the Hold BMI key     The display will momentarily show      d and then change to show the last height  Note  that the BMI annunciator will be turned on and that the height value will be flashing    Enter the new height by pressing the      key to increase the value or by pressing the          key to decrease the value     NOTE  Press and hold the       or        key to change the rapidly change the value   When the correct value for the height is displayed  press the Hold BMI key    The display will change to show HUL d and the Hold annunciator will be blinking   Have the patient step on to the scale     The scale will show the weight and then change to show the BMI value alternating  between the weight and BMI value       Press Hold BMI button to return the normal weighing mode     The patient can now step off the scale     SETTING THE AUTO OFF TIME    Press either the Adult or the Baby mode On Off key    Press and hold the Tare key until the display shows SEE    Release the Tare key  The display will change to A  GFF    Press the Tare key  The display will change to show the current setting   Press the Hold or Hold BMI key to step through the available auto off times   When the desired time is displaye
6. erference     You may find the booklet  How to Identify and Resolve Radio TV Interference Problems   prepared by the Federal Communications Commission helpful  It is available from the U S   Government Printing Office  Washington  D C  20402  Request stock No  001 000 0031 5 4     PROPER DISPOSAL    When this device reaches the end of its useful life  it must be properly disposed of  It must not  be disposed of as unsorted municipal waste  Within the European Union  this device should  be returned to the distributor from where it was purchased for proper disposal  This is in  accordance with EU Directive 2002 96 EC  Within North America  the device should be  disposed of in accordance with the local laws regarding the disposal of waste electrical and  electronic equipment     It is everyone s responsibility to help maintain the environment and  to reduce the effects of hazardous substances contained in electrical  and electronic equipment on human health  Please do your part by  making certain that this device is properly disposed of  The symbol  shown to the right indicates that this device must not be disposed of  in unsorted municipal waste programs        All rights reserved  Reproduction or use  without expressed written permission  of editorial or  pictorial content  in any manner  is prohibited  No patent liability is assumed with respect to  the use of the information contained herein  While every precaution has been taken in the  preparation of this manual  the Selle
7. ild      patient unattended while on the scale     Failure to maintain control of infant  child or patient at all times while they  are on the scale can result in serious injury to infant  child or patient        1  On Off  Baby Mode   1  Press this key to turn the scale ON     2  With scale on  press this key to turn the scale OFF   2  Hold  Baby Mode    1  Press this key to hold the weight value while weighing    2  Press this key again to disable the weight hold function    Hold BMI  Adult Mode    1  Press this key to hold the weight value while weighing    2  Press this key again to disable the weight hold function    3  Press and hold this key for 3 seconds to enter the BMI  Body Mass Index  mode to   calculate body fat     3  Tare  Baby and Adult Mode   Press this key to zero the scale before starting the weighing operation or to zero off the  weight of any item  i e  protective paper  blanket or pad  on the scale or in the baby tray     4  On Off  Adult Mode   1  Press this key to turn the scale ON   2  With scale on  press this key to turn the scale OFF          Minus Sign  Adult Mode  In the Adult mode  this key is used with the BMI feature to  decrease  the height value            Plus Sign  Adult Mode   In the Adult Mode  this key is used with the BMI feature to  increase  the height value     6 8535 M212 O1 Rev B    MB150    DISPLAY ANNUNCIATORS    5  BMI This annunciator is turned on when entering the height for the BMI feature and  when displaying the calculated
8. ns information on the operation of this scale  Please read it before  attempting to use the scale and keep it handy for future reference     SPECIFICATIONS    Adult  33010 x 0 216  150kg x 0 1kg   Baby  44lb x 0 02lb  20kg x 0 01kg     Function Keys  Adult  On Off  Hold BMI  Tare  Baby  On Off  Hold  Tare    Stabilization Time  1 to 2 Seconds    D    32 to 104  F  0  to 40  C   Display  1 0   25 mm  LCD display with 5 active digits  Power 15VDC   300mA AC Power Adapter  included  or  Requirements  Six    AA    alkaline batteries  not included   Dimensions   Tray  23    Lx 11    W x 4 3 4      585 x 280 x 120 mm   Scale  13 3 8  L x 13  W x 2    H   340 x 330 x 50 mm        8535 M212 O1 Rev B e MB150 1    BABY TRAY INSTALLATION    1  Install tray from the rear of scale  sliding it to the front of scale  toward the display   Note  that arrow on tray should point to front of scale        1  Turn scale upside down to screw tray and platform together properly        2 8535 M212 O1 Rev B    MB150    BABY TRAY INSTALLATION  CONT     3  Hand tighten the screws to secure the tray to the platform       8535 M212 O1 Rev B    MB150    AC POWER ADAPTOR    2  Locate AC Power adaptor jack at front of scale  The AC power jack is located on the lower  front right of the scale next to the Weight Unit Switch           AC Power Weight Unit  Adapter Jack Switch    2  Install AC Power Adaptor into jack on front of scale as shown below        4 8535 M212 O1 Rev B    MB150    INSTALLING REPLACING TH
9. r assumes no responsibility for errors or omissions   Neither is any liability assumed for damages resulting from use of the information contained  herein  All instructions and diagrams have been checked for accuracy and ease of application   however  success and safety in working with tools depend to a great extent upon the individual  accuracy  skill and caution  For this reason the Seller is not able to guarantee the result of any  procedure contained herein  Nor can they assume responsibility for any damage to property or  injury to persons occasioned from the procedures  Persons engaging the procedures do so  entirely at their own risk     Serial Number PRECAUTIONS    Date of Purchase Before using this indicator  read this manual               pay special attention to all  WARNING     Purchased From symbols     IMPORTANT A ELECTRICAL    RETAIN THIS INFORMATION FOR FUTURE USE WARNING          8535 M212 O1 Rev            150    INTRODUCTION    The Model MB150 Mother Baby Scale is a dual purpose battery operated scale  The scale  has two modes of operation  One mode will weight and compute the BMI  Body Mass Index   of an adult up      330lb  150kg   The second mode will weight a baby up to 44lb  20kg   The  scale is also equipped with a removable baby tray to allow weighing small children     The scale can be used in a fixed location with the included 15VDC AC Power Adapter or it can  be used as a portable scale with six  AA  batteries  not included      This manual contai
    