Home

Manual Media Converter EasyCON

image

Contents

1. Easy CON Media Converter User Manual Translation of Original docu Document Version 1 2 3 GOPEL GOEPEL electronic GmbH Goeschwitzer Str 58 60 eD 07745 Jena electronics 49 3641 6896 597 e ats_support goepel com e www goepel com O 2015 GOEPEL electronic GmbH All rights reserved The software described in this manual as well as the manual itself are supplied under license and may be used or copied only in accordance with the terms of the license The customer may make one copy of the software for safety purposes The contents of the manual is subject to change without prior notice and is supplied for information only The hardware and software might be modified also without prior notice due to technical progress In case of inaccuracies or errors appearing in this manual GOEPEL electronic GmbH assumes no liability or responsibility Without the prior written permission of GOEPEL electronic GmbH no part of this documentation may be transmitted reproduced or stored in a retrieval system in any form or by any means as well as translated into other languages except as permitted by the license GOEPEL electronic GmbH is neither liable for direct damages nor consequential damages from the company s product applications Printed 22 09 2015 All product and company names appearing in this manual are trade names or registered trade names of their respective owners Issue September 2015 Table of Contents 1 CONCEPT OF TH
2. as well as a stable Network connection have been established You may dowload this documentation also under www goepel com automotive test solutions easycon brr 2 6 Easy CON Media Converter Oe Accessories 3 Accessories As accessory for Easy CON the following devices are delivered 1 Wall Power Supply Figure 2 1 1 Adapter cable RJ45 to D Sub 9 poles GOPEL Qi Easy CON Media Converter 3 1 G GOPEL electronic A Accessories c ooccconcocnnononanonns 3 1 Adapter cable 2 4 C Concept of the device 1 1 Conections 2 2 E Easy CON Technical data 2 1 Easy CON Media Converter Index F First steps 2 6 I Interfaces iii 2 3 L LEDS nana 2 5 WwW Wall power supply 3 1
3. 1 2 2 2 Node 2 O GOPEL electronic 2 2 Interfaces Ethernet socket Physical layer 10Base T 100Base Tx Fast Ethernet Auto crossover MDI X Connector type R45 socket with Status LEDs Pin 10 100 BaseTx Tx Tx Rx not connected not connected Rx not connected COINID OA BR WIN not connected Physical layer BroadR Reach one pair Ethernet Connector type R45 socket with Status LEDs Pin BroadR Reach TRx TRx not connected not connected not connected not connected not connected COIN AD UI P wWIN re not connected Easy CON Media Converter Use of the Device 2 3 Use of the Device 2 4 Adapter cable RJ45 to D Sub 9 poles included in delivery CAT6 Patch cable truncated to D Sub 9 poles TRx Pin 4 and TRx Pin 5 Shield Pin 3 plastic cover Pin out D Sub Adapter cable D Sub plug RJ45 Pin BroadR Reach Pin BroadR Reach 1 not connected 1 TRx 2 not connected 2 TRx 3 Shield 3 not connected 4 TRx 4 not connected 5 TRx 5 not connected 6 not connected 6 not connected 7 not connected 7 not connected 8 not connected 8 not connected 9 not connected Easy CON Media Converter O GOPEL electronic Use of the Device 2 2 3 Status O GOPEL electronic Easy CON provides some info
4. E DEVICE rrr nnn 1 1 2 USE OF THE DEVICE s naexucna un Gu uauu na ii 2 1 2 1 SPECIFICATIONS AND CONNECTIONS AAA 2 1 2 1 1 Technical Data ANEREN 2 1 2 1 2 Conechon ANERER 2 2 2 13 Liability and Warranty Limitatioun 2 2 2 2 INTERFACES 2525522 aka nin a Ex Eua aaa ERR SERE RXE XY EE YE Rana anciana ionidacicasad 2 3 22 1 NOTE 2 3 22 2 NOTE 2 3 22 3 Kee rir ia DE RENE iat eee 2 5 2 3 FIRST STEPS iaa 2 6 3 ACCESSORIES E 3 1 GOPEL e Qi Easy CON Media Converter I Concept of the Device 1 Concept of the Device The Easy CON device from GOEPEL electronics connects automotive Ethernet networks using one pair BroadR Reach Ethernet as physical layer to standard LAN networks with 10Base T 100Base Tx physical layer The device comes with RJ45 connectors on both links This allows the use of shielded standard low cost high quality cables CAT5 or CAT6 for the test setup For easy connection to the ECU cabling harness an adapter cable with 9 Pol D Sub connector is included The Easy CON Media Converter can be operated as BroadR Reach Master or Slave Selection is easily done via a switch on the device s rear plate not visible in the following figure Figure 1 1 Easy CON GOPEL O Sectronic Easy CON Media Converter 1 1 Use of the Device 2 Use of the Device 2 1 Specifications and Connections 2 1 1 Technical EasyCON Media Convert
5. er Data Baud rate 10 MBit s 100 MBit s full duplex Forward Delay BroadR Reach to 100Tx 940 ns Forward Delay 100Tx to BroadR Reach 280 ns DC Supply voltage 4 75 V 5 25 V according to USB Specification micro USB socket DC Input power 2 W Operating temperature 40 C 80 C Protection IP 20 Dimensions 24 mm x 63 6 mm x 80 mm H x W x D Weight 112 g Power supply Figure 2 1 Power supply Cable length 1 m Output connector micro USB AC Input voltage 90 V 264 V AC Input current max 250 mA DC Output voltage 5 V DC Output current max 1000 mA Plug type Euro Power rating 5 W Ripple and Noise 200 mV Pk Pk Efficiency 74 Type Switch mode Class 2 Weight 80 g Input plug type EU US UK SAA Interchangeable Mains Connectors included Safety Approval IEC60950 1 UL cUL60950 1 LPS Be GOPEL e Qi Easy CON Media Converter 2 1 Use of the Device 2 1 2 Connection 2 2 2 1 3 Liability and Warranty Limitation Node 1 Ethernet socket must be connected to a 10Base T 100Base Tx Fast Ethernet device This can be an Ethernet Switch or another Ethernet card e g PC Most Ethernet cards will support 10Base T 100Base Tx Baud rate otherwise use an Ethernet Switch to connect to 1000Base Tx networks Use CAT5 or CAT6 patch cables The use of crossover cables is not required The Easy CON device has an integrated Auto crossover Switch detects the required connect
6. ion type and configures the connection appropriately Node 2 BroadR Reach socket must be connected to a BroadR Reach Ethernet device Use CAT5 or CAT6 patch cables or the provided D Sub 9 pol Adapter Please note BroadR Reach Ethernet devices can be either link master or link slave If the connecting device is a link master then the Easy CON device must be configured as slave If the connecting device is a link slave then the Easy CON device must be configured as master Use the Master Slave sliding switch at the rear plate near the BroadR Reach socket for this Please connect the micro USB connector to the Easy CON device and plug the enclosed power supply into a wall outlet The Easy CON media converter is not intended and has not been designed and tested for use in a safety relevant application Do not use the device for any safety relevant system or sub system inside a vehicle Using such a device inside a vehicle to control vehicle main functions can be dangerous and cause the whole vehicle to malfunction In no event shall GOEPEL electronics be liable for any direct indirect incidental special exemplary or consequential damages including but not limited to procurement of substitute goods or services loss of use data or profits business interruption injury or possible loss of life arising in any way resulting from the use of the Easy CON media converter device GO Easy CON Media Converter ON 2 2 1 Node
7. rmation regarding the device operating status and the status of the two links The individual Status LED at the front side indicates the following states YELLOW constant on Device initialization after RESET GREEN alternating BroadR Reach Link search GREEN constant on Broad R Reach Link no 10BaseT 100BaseTx Link BLUE constant on Broad R Reach Link 10BaseT 100BaseTx Link stable RED alternating Operational malfunction RED constant on Hardware malfunction 10BaseT 100BaseTx Phy Status LEDs socket near power supply 10BaseT 100BaseTx Phy Status LED 1 left GREEN constant on 10BaseT 100BaseTx Link stable GREEN alternating Link activity carrier found 10BaseT 100BaseTx Phy Status LED 2 right YELLOW constant on Link speed 100 Mbps OFF Link speed 10 Mbps BroadR Reach Phy Status LEDS socket near sliding switch BroadR Reach Phy Status LED 1 left YELLOW constant on Broad R Reach Link stable BroadR Reach Phy Status LED 2 right GREEN alternating Link activity Easy CON Media Converter 2 5 Use of the Device 2 3 First Steps 1 Connect your Easy CON device via the supplied USB cable with the supplied Wall Power Supply 2 Set the Sliding switch at the Easy CON to Master or Slave according to the application 3 Plug in the Network cable and BroadR Reach Adaptor according to the inscription of the casting 4 In the case the Status LED shines blue a stable BroadR Reach connection

Download Pdf Manuals

image

Related Search

Related Contents

75m/80m ロータリーダイポール CD78の修理  Hitachi GXV3140 User's Manual  Garmin Appliance Data Pilot's Guide Supplement    433MHz SINGLE CHANNEL, 1000 USER RECEIVER  VA TECH WABAG LIMITED  User Manual  Keysight 42941A Impedance Probe Kit  Kenmore Elite 30'' Down Draft Hood 59960 Specifications  Standard-Trainingskonsole – Bedienungsanleitung  