Home

User Manual Power Distribution Unit

image

Contents

1. 17 Metered Readout ssssssseeereneenerenns 17 Basic OPGratlo Misiecscesisscaccncvactvcndsetvvencoaeaieriyecascsceae 17 PDU Status Screen eee te 17 Current Level ssssseeeeeeeeene 17 Input Voltage eter rire xen 17 POW GW Screens E etu e Eee 17 IP Address nente 17 Outlet Control switched series only 17 LED Reversal OU series only 17 Environmental Monitoring optional 18 LED Indicators re terrere terrens 18 Device Reset eee reet erre tenet Ede ere 18 Remote Management eese 18 Unattended Automatic Shutdown 19 Firmware Upgrade e eeeeeeeeeeeeeee 19 Troubleshooting eeeeeee eere 20 Frequently Ask Questions FAQ 20 Conformance Approvals eeeeeees 20 Customer Service amp Warranty 21 Product Registrato N ssis 21 CyberPower International seeeeeeeeee 21 Limited Warranty 3a exire tve e ted tueeea 21 Appendix A Hyper Terminal 22 Appendix B Power Device Network Utility 23 eu e ais 23 Instalati ier ri re pene err aeree 23 Launch Program erst ri in t ccn t e a 24 Getting Started sss 24 Advanced Settings ccena nes 25 Model List
2. Use only the supplied hardware to attach the mounting brackets The PDU must be plugged into a three wire grounded outlet on a circuit that is protected by a fuse or circuit breaker For PDU15xxxxx series please use 15A circuit protector For PDU20xxxxx series please use 20A circuit protector For PDU30xxxxx series please use 30A circuit protector Connection to any other type of power outlet may result in a shock hazard Do not use extension cords or adapters with this PDU Never install a PDU or associated wiring or equipment during a lightning storm Ensure that the power cord plug and socket are in good condition To prevent the risk of fire or electric shock this PDU should be installed in a CAUTION temperature and humidity controlled indoor area free of conductive contaminants Do LL not install this PDU where excessive moisture or heat is present For more information on CyberPower products visit www CPSww com Prod Features Front panel description NEMA Type Series E owo 91 2 4 5 2 6 2 7 7 8 o A e A Power Cord Link Indicator B AC Output Outlets J Outlet Indicator
3. 1U Switched Series OU Monitored Series PDU15SWSFNET PDU15MV16FNET PDU15SWHVIEC8FNET PDU20MVT24FNET PDU20SWSFNET PDU20MVHVT24FNET PDU20SWT8FNET PDU3OMVT24FNET PDU20SWHVIEC8FNET PDU3OMVHVT24FNET 1U Monitored Series 2U Switched Series PDU15M8FNET PDU30SWT16FNET PDU15MHVIEC8FNET PDU3OSWHVT16FNET PDU20MSFNET PDUZOMTSENET 2U Monitored Series PDU20MHVIEC8FNET PDU30MT16FNET r PDU30MHVT16FNET OU Switched Series PDU15SWV16FNET PDU20SWVT24FNET PDU20SWVHVT24FNET PDU3OSWVT24FNET PDU3OSWVHVT24FNET Introduction Package Contents For 1U Series rr 49 PLV P 6 M3x6 Cord Retention Tray Mounting Screws Includes two spares 996999969 PPPLPPP P 6 M5x12 Screws 6 Washers Includes two spares for each PDU aa A g Mounting Bracket 2 short amp 2 long RJ45 DB9 Serial Port Connection Cable Od re V eC Cassia o 10 Flat Head M4x8 Bracket Mounting Power Cord 10 feet Screws Includes two spares IEC 320 C13 IEC 320 C14 PDU15SWHVIECSFNET PDU15MHVIEC8FNET Model Only Cem Power Cord 10 feet Cord Retention Tray IEC 320 C19 IEC 320 C20 PDU20MHVIEC8FNET Model Only PDU20SWHVIEC8FNET Card Cable Ties Qty 10 User Manual Registration Card CD Documentation For more information on CyberPower products visit www CPSww com Introduction Package Contents For OU Series 16 Outlets 24 Outlets 6 Flat Head M4x4 Bracket Mounting Screws Includes two spares Cord R
4. ENVIROSENSOR Port RJ45 modular port M Select Button Irt N PDU Status Screen uii O Reset Button Iia i C E w Technical Specifications Switched Series 0U 30A Monitored Series 0U 30A Model Name PDU30SWVT24FNET PDU30SWVHVT24FNET PDU30MVT24FNET PDU30MVHVT24FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 24A Plug Type NEMA L5 30P NEMA L6 30P NEMA L5 30P NEMA L6 30P Power Cord Type SR 10 AWG Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 24A penne ae Current 20A 15A 20A 15A Bank Number 2 Outlet Type NEMA 5 20R E A NEMA 5 20R E Outlet Number 24 21 3 24 20 4 Circuit Breaker Yes Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension itt 1778mm x Smm x d m 1690mm Son AA Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years 8 For more information on CyberPower products visit www CPSww com Product Features 2U Series Front panel description NEMA Type Ej A Power Cord J Lin
5. C Current Level switched series only D Input Voltage K Serial ENVIROSENSOR Port E Power RJ45 modular port F Load Indicator L Select Button G Ethernet Port M PDU Status Screen H Tx Rx Indicator N Reset Button Rear panel description a A External Site Ground Technical Specifications Switched Series 1U 15A Monitored Series 1U 15A Model Name PDU15SW8FNET PDU15SWHVIEC8FNET PDU1SM8FNET PDU15MHVIECSFNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 12A 12A UL 10A CE 12A 12A UL 10A CE Plug Type NEMA 5 15P IEC 320 C14 NEMA 5 15P IEC 320 C14 Power Cord Type SR 14 AWG Socket SR 14 AWG Socket Power Cord Length 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 12A 12A UL 10A CE 12A 12A UL 10A CE Outlet Type NEMA 5 15R IEC 320 C13 NEMA 5 15R IEC 320 C13 Outlet Number 8 Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension HxWxD 1 75 x 17 05 x 4 41 44mm x 433mm x 112mm Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals UL 60950 1 UL 60950 1 UL 60950 1 UL 60950 1 Certifications CSA C22 2 CSA C22 2 CSA C22 2 CSA C22 2 FCC Class A CE FCC Class A FCC Class A CE FCC Class A Warranty Product Warranty 3 years For more information on C
6. Enabled 3 Make sure the network connection is ready and power on the PDU 4 The PDU will obtain an IP address from the DHCP server automatically Option 3 Address Resolution Protocol ARP Command 1 Obtain the MAC address from the sticker on the PDU 2 Open a command prompt as an administrator and type the following arp s available IP address MAC address of PDU Example arp s 192 168 20 240 00 0c 15 80 00 01 IP Address MAC Address 3 Use the Ping command to assign a size of 123 bytes to the IP Type in ping 192 168 20 240 123 then press Enter If the replies are received your computer can communicate with the IP address Option 4 Hyper Terminal or Terminal Emulator In order for Hyper Terminal to interface with the PDU the PC server must be connected directly to the PDU via the serial port 1 Use the included RJ45 DB9 serial port connection cable attach one end to the serial port on the front of the PDU and the other end to the PC server 2 Open the Hyper Terminal software on your PC and select a name and icon for the connection 3 Setup the COM port settings using the following values Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None 16 For more information on CyberPower products visit www CPSww com Installation Guide 4 Type setup and press Enter to enter the Authentication menu 5 Enter the user name and password of the PDU device at the Authenticatio
7. Unit allows administrators an easy way to control AC power for various connected devices via network Installing the below software helps users to strengthen the PDU functions Power Device Network Utility The Power Device Network Utility gives users an easy to use interface to establish SNMP and network settings onthe PDU Install Power Device Network Utility PowerPanel Business Edition PowerPanel Business Edition provides the capability of unattended automatic shutdown of connected PCs servers to the PDU Install PowerPanel Business Edition Read Installation Guide Browse this CD Figure 1 Installation Menu Step 3 Select Next in the software wizard Step 4 Choose an installation directory and user settings Select Next Shown in Figure 2 i9 Power Device Network Utility Select Installation Folder The installer will install Power Device Network Utility to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder Install Power Device Network Utiity for yourself or for anyone who uses this computer Q Everyone Just me CAProgram Files CyberPower Power Device Network Utility Figure 2 Installation folder and settings Step 5 Select Next to comfirm the settings and install Step 6 Select Close to finalize the installation For more information on CyberPower products visit www CPSww com 23
8. equipment has been tested and found to comply with the limits fora Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any special accessories needed for compliance must be specified in the instruction This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice 1 An unshielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception It is essential that only the supplied power cord by used 2 Use only shielded cables to connect I O devices to this equipment Note THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPER
9. laser printers appliances aquariums medical or life support devices etc For more information on CyberPower products visit www CPSww com Customer Service amp Warranty What Are The Limitations 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been used at all times within the limitations on the Product s VA capacity 5 The sole and exclusive remedies of the Initial Customer are those provided by this Warranty Appendix A Hyper Terminal Hyper Terminal software can be used for basic PDU configuration It utilizes a text based interface and menu system Navigation through the
10. the PDU Input USER NAME and PASSWORD Upload cpspdubdata XXX bin ftp bin ftp gt put cpspdubdata XXX bin 10 Upgrade complete type ftp quit 11 The system will reboot after you type quit wo You can check to see if the firmware upgrade is successful by checking the Firmware version on the System gt About webpage Note Please do not turn the PDU off when processing the Firmware upgrade For more information on CyberPower products visit www CPSww com Troubleshooting Problem Possible Cause Solution PDU outlets do not 1 Breaker tripped Reset Breaker check if plug is provide power to 2 Loose power cord completely connected If the connected equipment problem remains contact tech support Amperage displayed 1 Overload The load indicator shows red on Metered Readout when overload Reduce the load exceeds the units on the PDU until the overload capability is gone If the problem remains contact technical support Circuit breakers have 1 Sustained overload Reset Breaker tripped 2 Excessive ambient or If the problem remains contact internal temperatures technical support 3 Faulty breaker Frequently Ask Questions FAQ Q What do do if I ve lost the Administrator username and or password A Resetting the PDU will set the username and password back to system default Please see the Device Reset section to reset the PDU Conformance Approvals WARNING This
11. within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our liability is limited to the amount if any stated in the Technical Specifications Who Pays for Shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as
12. ATE THE EQUIPMENT The Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada 20 For more information on CyberPower products visit www CPSww com Customer Service amp Warranty Product Registration Thank you for purchasing a CyberPower product Prompt product registration entitles coverage under the Limited Warranty and also allows the opportunity to be notified of product enhancements upgrades and other announcements Registration is quick and easy at www cpsww com support warranty registration html CyberPower International Feel free to contact our Tech Support department with installation troubleshooting or general product questions CyberPower Taiwan Phone 0800 288 966 Email sales cpsww com tw Web www cpsww com tw CyberPower North America Phone 952 403 9500 Toll free 877 297 6937 Email tech cpsww com Web www CPSww com Add 4241 12th Avenue E Suite 400 Shakopee MN 55379 Hours of Operation Monday Friday 8 00 AM 5 00 PM CST CyberPower Europe Email sales cpsww eu Web www cpsww eu Limited Warranty Read the following terms and conditions carefully before using the CyberPower PDU series By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty If you do n
13. Appendix B Power Device Network Utility Launch Program To launch the Power Device Network Utility and get started select Programs from the Start menu in Windows and locate the new folder and icons for Power Device Network Utility Select Power Device Network Utility from the program folder Shown in Figure 3 internet Set Program Access and Defaults Internet Explorer W Windows Catalog E mail a Outlook Express AM Windows Update Accessories WordPad e G Bi Microsoft Platform SDK For Windows Server 2003 R2 8 Startup Internet Explorer LECI ES Outlook Express Remote Assistance Windows Media Player 43 Windows Messenger Wy Windows Movie Maker Debugging Tools For Windows k Utili n Figure 3 Power Device Network Utility Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and gateway address This allows the device s to function properly on the network and interface with CyberPower Management Console Step 1 Select the appropriate PDU device from the Equipment List Shown in Figure 4 Power Device Network Utility IP Address Subnet Mask Gateway DHCP Nam gOD 0C 15 40 09 A9 1921682420 255 255 255 0 19216824254 Enable PDU2 Figure 4 Equipment List Note If the PDU does not appear o
14. CyberPower yDEY 1 Quality Value User Manual Power Distribution Unit Table of Contents MOGI LISt q 1 Titre fast p sa 1 Package Contents inss e precor eee e eden egere 1 For 1U S ries ciere rer eer ees 1 F r OU Series incer edet pe ee een 2 F r 2U SOLOS iei rr E REP aes 3 Safety Precautions sisestus 3 Proruct FEATURES is une tn e rx nhe ees 4 TU 15A Serles eee teer erre 4 Technical Specifications eesessssssse 4 TU20A SSFIGS iiu coe o rete eee n 5 Technical Specifications sseesssss 5 OU TSA SOFIE neie eR ue 6 Technical Specifications cccccccccceseestseeeeeeeeeees 6 OU 20A Serles osos eterne e edes 7 Technical Specifications eesessssssse 7 OU SOA SERIES orsi peteret oret reus 8 Technical Specifications eeeesssessse 8 2U Series ust ere rene iei tures 9 Technical Specificato ssion iiia 9 Installation Guide eee eere 10 Horizontal Installation eene 10 For IU Model neret oec e 10 For 2U Model 11 Vertical installation 5 rtt es 13 For TU Model a i ete ehe ree teret 13 For OU Model with Bracket ss 13 For OU Model with Keyhole Mount 15 Electrical installati n rreri isinan tene 15 Network Installation cessere 16 lenricu
15. P UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension HxWxD 1 75 x 17 05 x 4 41 44mm x 433mm x 112mm Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals UL 60950 1 UL 60950 1 UL 60950 1 UL 60950 1 Certifications CSA C22 2 CSA C22 2 CSA C22 2 CSA C22 2 FCC Class A CE FCC Class A FCC Class A CE FCC Class A Warranty Product Warranty 3 years For more information on CyberPower products visit www CPSww com Product Features OU 15A Series Front panel description Ho Rear panel description A Power Cord A Bracket Screw Hole B AC Output Outlets B Keyhole Mount Peg C Current Level Screw Hole D Input Voltage p 5 lo E Power F Load Indicator To G Ethernet Port I H Tx Rx Indicator Link Indicator J Outlet Indicator switched series only T K Serial He ENVIROSENSOR Port zi RJ45 modular port 9 w L Select Button o L Ours M PDU Status Screen o laor N Reset Button Te mas B BOR slm IN 9 o FI _ b z o BL NRI loo lo A Bi loo sa Technical Specifications Switched Series 0U 15A Monitored Series 0U 15A Model Name PDU15SWV16FNET PDU15MV16FNET Input Nominal Voltage 100 120V Frequency 50 60Hz Derat
16. cable attach one end to the Ethernet port on the front of the PDU and the other end to a network port Step 2 Establish the PDU IP address Assigning an IP address to the CyberPower PDU requires the user to have an available IP address that is valid on the respective network If an available IP address is unknown contact the network administrator to obtain one The default IP is 192 168 20 177 and the default DHCP function is on There are multiple methods for setting up the IP address on the PDU Please follow the instructions below for the method that is appropriate for your application Please make sure the PDU is powered on during this process Option 1 recommended Power Device Network Utility 1 Use the included PDU Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start gt Power Device Network Utility 3 Highlight the PDU device from the list and select Edit and Setup device gt Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your network settings 5 Enter the user name and password of the PDU device at the Authentication menu Note The default username is cyber and the default password is cyber For further information and installation instructions see Appendix B Option 2 DHCP Server 1 Ask your administrator if there is DHCP server on the LAN 2 Make sure the DHCP is
17. configuration please refer to the PDU Software Installation CD LED Indicators Indicator Status Description Green The total PDU power load is normal Load Orange Near overload Red Overload Off The PDU power is off On Green The PDU power is on Tx Rx Elash Receiving transmitting data packet as Reset finished On Indicates the PDU is connected to the LAN LINK P Off Indicates the PDU is not connected to the LAN On The outlet is on and providing power Outlet Off The outlet is off Device Reset To reset all the settings to default except for the IP address press and hold the Reset Button for 3 seconds To reset all the settings to default press and hold the Reset Button for 6 seconds Remote Management The remote management function of the CyberPower PDU provides for monitoring the PDU vitals controlling outlets and utilizing SNMP functionality Remote management is performed via the web interface To access the web interface please follow the instructions below 1 Enter the IP address of the PDU into a web browser Internet Explorer Firefox 2 Enter the user name and password of the PDU device at the authentication screen Note The default username is cyber and the default password is cyber For additional information about the features and functionality of CyberPower Management Console please refer to the PDU Softwar
18. e Installation CD 18 For more information on CyberPower products visit www CPSww com Operation Unattended Automatic Shutdown PowerPanel Business Edition software automatically intitiates a graceful shutdown on the operating system in an orderly fashion PowerPanel must be installed on every PC for which the shut down is to take place The PC receives SNMP messages directly from the PDU and these messages can be scheduled for an exact date time or can be performed immediately Follow the directions below for setting up Unattended Automatic Shutdown Step 1 PC Configuration 1 Install PowerPanel Business Edition Client on every PC that will be part of the shut down process Follow the instructions in the PowerPanel Business Edition Client user manual 2 Configure the settings in PowerPanel Business Edition Client See the PowerPanel Business Edition Client User Manual for additional help Step 2 PDU Configuration 1 Verify that the IP address of all PCs that will be part of the shut down process are included in the Client List of web interface For additional information please refer to the user s manual in the PDU Software Installation CD Step 3 Notification Notifying the PCs of potential outlet shutdown can be accomplished using the following methods Outlets Control Menu Performing the task of turning off or rebooting outlets Scheduling Menu Setting the scheduler to perform the task of turning off or rebooting o
19. ed Input Current 12A Plug Type NEMA 5 15P Power Cord Type SR 14 AWG Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V Derated Output Current 12A Outlet Type NEMA 5 15R Outlet Number 16 Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension HxWxD 49 x 2 20 x 1 75 1245mm x 56mm x 44mm Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years For more information on CyberPower products visit www CPSww com Product Features OU 20A Series Front panel description NEMA Type IEC Type Rear panel description A Power Cord B AC Output Outlets 40 C Current Level D Input Voltage E Power A Bracket Screw Hole F Load Indicator B Keyhole Mount Peg G Ethernet Port Screw Hole H Tx Rx Indicator Link Indicator J Outlet Indicator switched series only K Serial ENVIROSENSOR Port RJ45 modular port L Select Button M PDU Status Screen N Reset Button TO o Technical Specifications Switched Series OU 20A Monitored Series OU 20A Model Name PDU20SWVT24FNET PDU20SWVHVT24FNET PDU20MVT24FNET PDU20MVHVT24FNET Inpu
20. etention Trays Qty 2 16 Outlets Qty 3 24 Outlets Cable Ties Qty 20 16 Outlets Qty 30 24 Outlets rrr q9 o5 rr PSF e Cord Retention Tray Mounting Screws M3x6 Qty 10 for 16 Outlets Qty 14 for 24 Outlets Includes two spares 999999 db d d d M 6 M5x12 Screws 6 Washers Includes two spares for each DD rere amp 2 Keyhole Mounting Pegs with 4 M4x5 Screws Includes two spares RJ45 DB9 Serial Port Connection Cable Registration Card User Manual Registration Card CD Documentation For more information on CyberPower products visit www CPSww com Introduction Package Contents For 2U Series e e rr Fr 9 9 Ky i rr rrF Mounting Brackets x 2 10 M3x6 Cord Retention Tray Mounting Screws P 2 Includes two spares lS v oT v 000000 M3 J ap d Pr SPP SF 9 o9 10 Flat Head M4x8 Bracket Mounting 6 M5x12 Screws 6 Washers Screws Includes two spares Includes two spares for each Cord Retention Trays x2 RJ45 DB9 Serial Port Connection Cable Cable Ties Qty 20 User Manual Registration Card CD Documentation Before using please check to ensure the package contains all the items shown above If there are missing parts please contact your local CyberPower refer to CyberPower International P 21 Check for technical support Safety Precautions Read the following before installing or operating the Power Distribution Units PDU
21. interface is done by typing the number of the menu option and pressing the Enter key Note The session will timeout and logout after 3 minutes of inactivity Menu options are shown below Main Menu 1 Outlet Manager Switched Series Only 2 Network Settings 3 System Configuration 4 Account Settings 5 Configure System to Default 6 Logout Outlet Manager 1 Outlet Control 2 Outlet Configuration Network Setting Physical MAC Address 00 0C 15 40 08 A9 1 System IP 192 168 24 20 2 Subnet Mask 255 255 255 0 3 Default Gateway 192 168 24 254 4 DHCP Enabled 5 Http Port 80 6 Http Access Enabled System Configuration 1 Date mm dd yyyy 11 11 2011 2 Time hh mm ss 17 17 25 3 Name PDU20SW8FNET 4 Contact Administrator 5 Location Server Room Account Setting 1 Administrator 2 Viewer Web Only Configure System to Default Sure to Configure System to Default 1 Yes 2 NO 22 For more information on CyberPower products visit www CPSww com Appendix B Power Device Network Utility Overview The CyberPower Power Device Network Utility is an easy to use interface which is used for establishing IP addresses on CyberPower PDU devices Installation Step 1 Insert the CD labeled PDU Software Installation CD into the CD DVD drive Step 2 Select Power Device Network Utility from the installation menu Shown in Figure 1 A The PDU Power Distribution
22. k Indicator B AC Output Outlets K Outlet Indicator C Input Circuit Breaker switched series only D Current Level L Serial ENVIROSENSOR Port E Input Voltage RJ45 modular port F Power M Select Button G Load Indicator N PDU Status Screen H Ethernet Port O Reset Button Tx Rx Indicator Rear panel description com x o A External Site Ground Technical Specifications Switched Series 2U Monitored Series 2U Model Name PDU30SWT16FNET PDU30SWHVT16FNET PDU30MT16FNET PDU30MHVT16FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 24A Plug Type NEMA L5 30P NEMA L6 30P NEMA L5 30P NEMA L6 30P Power Cord Type SR 10 AWG Power Cord Length 10 ft 3 05 m 12 ft 3 65 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 24A penne a Current 20A 15A 20A 15A Bank Number 2 Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R piri d Outlet Number 16 Circuit Breaker Yes Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension HxWxD 3 5 x 17 05 x 4 41 88mm x 433mm x 112mm Environmental Humidity 0 to 9596 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 104 F 0 C to 40 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years For more inf
23. k Setting Menu Device Setup Note The DHCP option is not available for all power devices Step 3 Authentication Enter the user name and password of the PDU device at the Authentication menu Shown in Figure 7 Note The default username is cyber and the default password is cyber Authentication Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit gt Timeout Settings is used to specify the wait time when scanning for network PDU devices When there are many devices on the local network it may take extended periods of time to locate all the devices The timeout function is used to limit the search time The default setting is 3 seconds Valid values are 3 to 60 seconds Timeout Setting Figure 8 Timeout Setting For more information on CyberPower products visit www CPSww com CyberPower Reliability Quality Value CyberPower Systems Inc www CPSww com K01 0000181 03
24. lied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray 14 For more information on CyberPower products visit www CPSww com Installation Guide For OU Model with Keyhole Mount Step 1 Keyhole Mount Installation Use the provided Screws 2 to attach the Keyhole Mounting Pegs 2 to the PDU Step 2 PDU Mounting Align the Keyhole Mounts to the Keyhole Slots on the rack Insert and slide down to lock firmly into the place E e Electrical Installation Step 1 Receptacle evaluation Ensure that the plug type of your PDU unit matches the wall receptacle type that you are using The PDU must be plugged into a three wire grounded wall receptacle only The wall receptacle must also be connected to CAUTION a appropriate branch circuit main with fuse or circuit breaker L 3 protection Connection to any other type of wall receptacle may result in a shock hazard Step 2 Plug the PDU into the wall receptacle For more information on CyberPower products visit www CPSww com 15 Installation Guide Step 3 Attach equipment It is extremely important not to exceed the PDUs maximum current load as outlined in the Specifications section In order to determine your total load simply use the Metered Readout on the front of the PDU Network Installation Step 1 Attach the LAN Cable Using a CAT5 RJA5
25. n menu Note The default username is cyber and the default password is cyber For further information and configuration via Hyper Terminal see Appendix A Hyper Terminal Operation Metered Readout The Metered Readout provides instant status updates of the PDU s Voltage Current Power conditions as well as the local IP address of the unit to the user In addition it also allows the user to control each outlet of the PDU Basic Operation Screen Selection To toggle the different status screens press the Select button next to the PDU status screen Pressing the Select button once will toggle to the next status screen Pressing and holding the Select button for 3 seconds will display the local IP address of the unit Pressing and holding the Select button for 6 seconds will enter the outlet control mode PDU Status Screen Current Level Amps Volts KW The Current Level screen shows the total current draw of the connected equipment Units are listed in Amps Input Voltage The Input Voltage screen measures the AC voltage that the aes system is receiving from the utility wall receptacle This KW can be used as a diagnostic tool to identify poor quality input power Units are listed in Volts Power Amps The Power screen shows the total power that the devices KW connected to the PDU consumes Units are listed in kilowatts IP Address Amps The IP Address screen displays the local IP address
26. n the list click the Refresh button to rescan the network If it still does not appear ensure that the PDU is turned on and was installed correctly Pressing Stop will cancel the scan refresh process Note If your computer has a software firewall installed you may see a Windows Security Alert message Shown in Figure 5 In Windows XP SP2 the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Windows Security Alert x T To help protect your computer Windows Firewall has blocked Y J some features of this program NA Do you want to keep blocking this program ay Name Power Device Network Utility Publisher Unknown Windows Firewall has blocked this program from accepting connections from the ream O a pde If oa Tecos Mon roam ot tt Us eet JO n unblock R When should unblock a program Figure 5 Windows Security Alert 24 For more information on CyberPower products visit www CPSww com Appendix B Power Device Network Utility Step 2 Assign a valid IP Address to the PDU Option 1 Assisted Setup recommended With the appropriate device selected from the Equipment List open the Network Settings menu Shown in Figure 6 Tools gt Device Setup In the Device Network Setting Menu enter a valid IP address subnet mask and gateway address to setup the PDU device Device Network Settings Come Cancer Figure 6 Networ
27. ntion Tray Installation optional Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray Ce s 12 For more information on CyberPower products visit www CPSww com Installation Guide Vertical Installation For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU Step 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system Veooorrrrcccce f 20 00000000000000000000000000000000000000000000000000000000000 9000000000000000000 Bue Cure For OU Model with Bracket Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 4 to attach the Mounting Brackets 2 to the PDU For more information on CyberPower products visit www CPSww com Installation Guide Step 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system yivoccooco 909209000000009000090000090009000000090090000000000090920 v NN 90000000000000900000000000000000000000000000000000000000000000 Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the supp
28. of the Volts PDU unit Note If the PDU is not connected to a LAN the readout will display the default IP address Outlet Control switched series only The Outlet screen shows the condition of each outlet in vos 540 sequence When the outlet is on the light below this outlet will be on and a square appears in the upper right re EEA area next to the number of the outlet To switch the outlet Volts off press the Select button once and the square will move M to the lower right After 1 second the outlet will turn off LED Reversal OU series only The LED status screen can be set to display upside down from standard through the Web Interface as shown in figures below Note the decimal point will not be moved and will instead be on the top if this option is enabled For more information on CyberPower products visit www CPSww com Operation Environmental Monitoring optional CyberPower PDUs along with the environment sensor ENVIROSENSOR provide the function of temperature and humidity monitoring in a server closet and or datacenter remotely To connect the PDU with ENVIROSENSOR use the RJ45 Ethernet Cable Plug one end into the Serial ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR as shown in figures below When the PDU correctly connects to the ENVIROSENSOR users can see the temperature and humidity data on the Web Interface For further information regarding ENVIROSENSOR
29. ormation on CyberPower products visit www CPSww com Installation Guide CAUTION Please use only the provided screws through the entire L a installation process Horizontal Installation For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU If you plan on attaching the Cord Retention Tray to the PDU you will need to use the LONG Mounting Brackets 2 Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system EN 292992922 7 wo o o o o o o o 10 For more information on CyberPower products visit www CPSww com Installation Guide Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 4 supplied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray EN 222992 Oo O O O O O O Oo For 2U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the Mounting Brackets 2 to the PDU For more information on CyberPower products visit www CPSww com Installation Guide Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system Y ooecooocoooc000000000 Step 3 Cord Rete
30. ot agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who Is Providing This Warranty CyberPower Systems Taiwan Inc CyberPower Systems USA Inc CyberPower Europe CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions What Is the Period of Coverage CyberPower provides a 3 Year warranty to the original purchaser who owns the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 You can use the contact information mentioned above for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a purchase receipt or other proof of the original purchase and provide a description of the defect What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective
31. t Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 16A Plug Type NEMA L5 20P NEMA L6 20P NEMA L5 20P NEMA L6 20P Power Cord Type SR 12 AWG Power Cord Length 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 16A Outlet Type NEMA 5 20R Races NEMA 5 20R pae ise Outlet Number 24 2143 24 2044 Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical Dimension HxWxD 66 53 x 2 20 x 1 75 1690mm x 56mm x 44mm Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 113 F 0 C to 45 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years For more information on CyberPower products visit www CPSww com Product Features OU 30A Series Front panel description Rear panel description NEMA Type IEC Type A Bracket Screw Hole B Keyhole Mount Peg A Power Cord B AC Output Outlets C Input Circuit Breaker Screw Hole D Current Level E Input Voltage F Power G Load Indicator H Ethernet Port Tx Rx Indicator J Link Indicator K Outlet Indicator switched series only L Serial
32. utlets The notification will occur prior to the scheduled date time Outlet Overload In event of a PDU overload notification will be sent prior to the PDU shutting down Firmware Upgrade By upgrading the Firmware you can obtain new features and updates improvements to existing functionality There are two files to update in order to upgrade the firmware version cpspdubfw_XXX bin cpspdubdata_XXX bin Note that the XXX is not part of the file name but is where the version number in the filename is given Use the following steps to upgrade the firmware 1 Download the latest firmware from cpsww com 2 Extract the file to C 3 Open a command prompt window and navigate to C 4 Login to the PDU with FTP command type ftp after entering ftp mode ftp gt will display in the command prompt as shown below instead of C ftp gt open To current IP of the PDU port for example To 192 168 22 12 21 21 is the default ftp port for the PDU Input USER NAME and PASSWORD same as the administrator account in Web interface default cyber cyber Upload the cpspdubfw XXX bin type ftp bin ftp gt put cpspdubfw XXX bin 6 Upgrade complete type ftp quit Un 7 The system will reboot after you type quit This reboot will take approx 30 seconds 8 Login to the FTP again ftp ftp open To current IP of the PDU port for example To 192 168 22 12 21 21 is the default ftp port for
33. yberPower products visit www CPSww com Prod Features 1U 20A Series Front panel description NEMA Type C Jogoo 92 o3 04 05 6 7 8 a A Q A Power Cord I Link Indicator B AC Output Outlets J Outlet Indicator C Current Level switched series only D Input Voltage K Serial ENVIROSENSOR Port E Power RJ45 modular port F Load Indicator L Select Button G Ethernet Port M PDU Status Screen H Tx Rx Indicator N Reset Button Rear panel description A External Site Ground Technical Specifications Switched Series 1U 20A Monitored Series 1U 20A Model Name EDUZOSWBENEL PDU20SWHVIECSFNET POUZOMBENEL PDU20MHVIECSFNET PDU20SWTSFNET PDU20MT8FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current 16A Plug Type _NEMAS20P ecazacea BAS 20P IEC 320C20 NEMA L5 20P NEMA L5 20P Power Cord Type SR 12 AWG Socket SR 12 AWG Socket Power Cord Length 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current 16A Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R IEC 320 C13 Outlet Number 8 Networking Protocol Support TCP I

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 生垣バリカン  Racing Wheel for PS®3/PS®2/PC  Planar Systems PX2491W  GP7000F M800, M1000, M2000  Samsung S32D850T מדריך למשתמש  Manual-I: IG for QuadroFXO  Thermalright HR-55  Precision Physical Users Manual    Manual de usuario sistema Geoportal Versión 1  

Copyright © All rights reserved.
Failed to retrieve file