1. in frame and a hand controller The walling in frame and outer wall grille are built or screwed to the wall The mixing cabinet and the unit are then fitted See diagram 2 The control lever consists of a fixture arm a wall fixture a ball and two adherent joints A pull rod is used between the joints not included Function S Position of the output selector see 6 Toggle switch position C means the thermostat only controls the output the fan runs continuously E N In position C the fan is controlled by a special thermostat which only switches L J on the fan when the heat is on Th It is possible that the temperature limiter may have tripped during transport if the unit does not function the first time it s switched on Rectify as set out in the description under Overheating Fig 1 Overheating If the unit overheats the integrated temperature limiter will trip Reset the temperature limiter after the unit has cooled and the fault rectified Fig 1 NOTE All work inside the unit s connection area should be carried out by an authorized technical and the unit must be dead The temperature limiter is reset by removing the cover and pressing the button on the temperature limiter Fig 1 Care The heater fans do not normally need any maintenance Nevertheless dirt and dust can cause overheating and represent a f re risk Accordingly the unit should be
2. cleaned regularly Residual current circuit breaker E When the installation is protected by means of a residual current circuit breaker which trips when the appliance is connected this may be due to moisture in the heating element When an appliance containing a heater element has not been used for a long period or stored in a damp environment moisture can enter the element This should not be seen as a fault but is simply rectified by connecting the appliance to the mains supply via a socket without a safety cut out so that the moisture can be eliminated from the element The drying time can vary from a few hours to a few days As a preventive measure the unit should occasionally be run for a short time when it is not being used for extended periods of time Safety For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used e The unit has hot surfaces when running The unit must not be positioned so that inflammable material cam ignite The unit must mot covered fully or partially with clothes or similar material as overheating can result in a fire risk The unit must not be placed directly under fixed wall sockets This appliance is not intended for use by persons including children with reduced physical or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con
3. Original instructions CAT B mm mm mm 335 255 276 C5 335 255 276 c9 405 315 335 c9 127 121 121 Z min 300 mm min 300 mm Minimum distance in a permanent assembly 127 07 295 06 5 400 200 295 s 8 165 gt gt 1 ke el 295 Fig 2 Mixing cabinet accessory 70 8 160 Accessories EV300 CBT CMB35 Cat Typ E nr RSK nr EL nr NRF nr HxBxD SE SE NO NO mm 105 85 809 33 6728499 54911 12 85 024 49 80 80 31 105 85 809 34 6728500 5491113 85 024 51 80 80 31 00 87 513 93 54 910 57 100 80 90 87 511 87 5431202 85 021 79 155 87 43 CMB35 87 112 20 49 306 10 400x295x170 TP3 5 49 306 90 49 306 10 Technical data Type E nr SE EL nr NO Output Airflow Sound Voltage Amperage HxWxD Weight steps level kw m h dB A C IV A mm kg C3 871103 4930613 0 15 3 280 41 32 230V 400V3N 13 2 4 4 255x335x276 6 3 5 8711105 4930615 0 2 5 5 480 40 31 400V3N 73 255 335 276 6 7 c9 87 11109 4930619 0 4 5 9 720 44 37 400V3N 13 1 315x405x335 10 2 1 Conditions Distance to the unit 3 metres Directi
4. cerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Main office Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 2825 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se Art nr 201233 2014 04 03 HH AC SA SA
5. h at least a3 mm gap and preferably fitted with a status lamp The Cat fan heater is intended for permanent installation The knockouts at the rear of the unit are used to connect accessories 3 can also be connected to single phase 230V On the back of the appliance there are knock outs Cable glands used must guarantee the protection class requirements The heaters can be connected for either 230V3 and 400V3N Note Other models cannot be connected for single phase Start up E When the unit is used for the first time or after a long period of disuse smoke or odour may result from dust or dirt that has collected on the element This is completely normal and disappears after a short time Assembly The Cat fan heater is mounted on a wall and has a fixed tilt angle 10 downwards which gives balanced and good heat distribution e Note that the minimum distances sat out in the figure on page 2 must be maintained The unit must be installed with the connection area to the left as seen from the front e Mark out and drill the holes for the screws as set out in the diagram on page 2 Screw the screws for the keyholes so that approximately 10 mm remains Hang up the unit and tighten the screws e Screw the last screw Installation with mixing cabinet Mixing cabinet CMB35 fits and C5 The mixing cabinet is available as an accessory and consists of an outer wall grille a walling
6. onal factor 2 Equivalent absorption area 200 m 2 At temperature rise of passing air at maximum heat output 3 can be connected for 230V and 400V3N Other models should not be connected for single phase 230V Protection class Cat IP44 splash proof design CE compliant CAT 3 5 9 kW 230V3 400V 3N CBT EV300 230V3 400V3N Nj Assembly and operating instructions General Instructions Read these instructions carefully before installation and use Keep this manual for future reference The product may only be used as set out in the assembly and operating instructions The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions Application area Cat is a range of compact and quiet fan heaters for stationary use It is ideally suited for small stockrooms in a garage workshop or shop The mixing cabinet accessory allows heating and ventilation to be combined through mixing the return air and outdoor air Protection class IP44 Electrical Installation The installation should be permanent and carried out by a qualified technician according to applicable directives The installation should be preceded by a fully isolating switch wit
Download Pdf Manuals
Related Search
Related Contents
Un Quenal des Queneau Polycom CX5000 User Guide Samsung NV100HD Наръчник за потребителя 未命名 -1 - aebath.com Gigaset S100 /150 colour Benutzerhandbuch Sandfilteranlage performer rpm twin cam®cnc-machined Philips Humidification filter HU4102 Forno micro Istruzione - kramer italia srl Copyright © All rights reserved.