Home

USER MANUAL - Pool Technologie

image

Contents

1. ventilate the pool regularly so as to avoid dissolved gases accumulating which could disrupt the measurements of pH or chlorine probes The manufacturer is not liable for the non observance of the maintenance instructions Your device allows you to carry out different operations detailed below Button C allows to you stop an operation which is running at any time so you can go back to the main menu A INTRODUCTION Depending on the model 1 2 or 3 pumps the device may have the following functions disinfection pH algaecide Select a function with the buttons To make it easier the display shows differently according to the functions Single flash pH function displayed Double flash disinfectant function displayed Triple flash algaecide function displayed For each of these functions the following table shows the parameters which can be modified by the user Parameters which can be modified Algaecide Manual injection dose in ml upon each MA do Start up Manual injection dose in ml hour MA do pH Manual injection pool volume pH probe MA SE CP Ad adjustment probe calibration pH corrector CA Co B INSTRUCTIONS To modify the parameters of a function Choose the function using the buttons Then hold the button V for 3 secs to access the parameters which can be modified Choose the code of the parameter to modify using the buttons then confirm with V The pa
2. country Do not cover it A Any contact between the controller and the water in the pool may risk electrocution v The pH controller must be permanently connected to the filtration controller and slaved to the pump contactor Do not use an extension cord with a plug or use a plug to connect the unit Turn off the differential circuit breaker beforehand Ensure that the controller switches off when the filtration pump stops 2 Attachments Type 1 pump disinfectant v Place the pipe collar for the disinfectant injection on the pipe beside the pool turning the opening 1 2 preferably upwards Mark then drill the pipe Mount the injection connector on to the pipe collar with Teflon v Connect the inlet filter to the pump with a part of the colored tubing supplied Follow the direction of the arrows on the cover of the pump v Connect the outlet of the pH pump to the injection connector with a piece of the tubing supplied v Connect the pump to the controller Type 2 pumps disinfectant pH v Place the first pipe collar in the middle of a horizontal pipe of a minimum of 40 cm Turn the opening 2 upwards Mark then drill the pipe Mount the probe holder on the pipe collar with Teflon Take off the rubber protection from the pH probe then mount it on the probe holder Ensure it is not stuck in the pipe SN Connect the cable from the pH probe BNC plug to the bottom of the controller Keep it away from all other ele
3. maintenance kit R f KITO2MAINMTP contains all of the parts necessary for annual maintenance operation 12 IX WARRANTY All our care and technical expertise has gone into making this device It has undergone quality control If in spite of all care and knowledge which has gone in to its manufacture you have to use our warranty free replacement only applies to parts of our equipment which are defective Duration of the warranty 2 YEARS for New material controller 1 YEAR for the pH probe basic probe excluded 1 Month for After Sales Repairs and spare parts Authentic invoice date Warranty objects The warranty applies to all parts with the exception of consumables which must be replaced regularly The device is covered for any manufacturing defect only when it has been used normally in a family pool Use in public pools voids the warranty After sales service v All repairs are done in our work shop All transport fees are payable by the user There will be no compensation for immobilisation and privation of the equipment when it is being repaired v In any case the equipment is always carried at the user s own risk It is up to the latter to check that it is in perfect condition before the order is collected and if need be to state any reservations on the carrier s slip Confirm this with the carrier within 72 hours by registered letter with an acknowledgement of receipt IMPORTANT A replacement under guarant
4. TALLATION A INTRODUCTION This manual covers the three automatic dosing models e Model pump for the simple disinfection of the pool e Model 2 pumps for the disinfection and the pH regulation of the pool e Model 3 pumps for the disinfection the pH regulation and the algaecide treatment of the pool serre proceeding with the installation of the device it is very important to check the following points v The technical area should be dry and properly ventilated protected from rain splashes discharges of water and UV radiation Provide a space for the tank with the pH corrector which is a sufficient distance from the electrical appliances or any other chemical containing product Non compliance with this instruction will lead to abnormal oxidation of the metallic parts which may result in the device break down v Assembly of the dosing controller and its attachments must strictly conform to the following installation diagram Installation diagram JUSTDOSING 3 pumps CONTROLLER PUMP TIMER 230 V il FLOW OUT Ty E FILTER RAE 7 JP ALGICIDE CONTAINER DESINFECTANT LE td bal CONTAINER pH CORRECTOR FLOW IN B INSTRUCTIONS 1 Controller v Choose an area which is easily accessible close to the electronic filtration box Install the controller vertically far enough away from the pool to respect the regulation distances of your own
5. USER MANUAL AUTOMATIC DOSAGE 1 pump 2 pumps 3 pumps if FAMILY POOLS UP TO 100 m Ref PAPI004051 GB REV 11 08 TABLE OF CONTENTS I SAFETY INSTRUCTIONS II PACKING LIST II INSTALLATION IV ACTIVATION V MAINTENANCE VI ALARMS VI WINTERING Vill WARRANTY IX ENVIRONMENT PRESERVATION Pool Technologies declares this equipment complies with the following E U directives Electromagnetic Compatibility Directive 89 336 EEC modified 92 31 EEC and 93 68 EEC Low Voltage Directive 73 23 CEE modified 93 68 EEC Chief Executive TE aes nn M a To improve product quality the manufacturer reserves the right to modify production at any time and without notice I SAFETY INSTRUCTIONS READ AN FOLLOW ALL INSTRUCTIONS SAVE ALL INSTRUCTIONS A In the manual this symbol indicates a WARNING It informs you of the risk of damage to the equipment or of serious injury It is very IMPORTANT that you pay attention to these warnings WARNING RISK OF ELECTRIC SHOCK The safety instructions outlined in this manual are not exhaustive They highlight the most common risks of using electrical equipment in presence of water Any installation and use of this equipment should be carried out with caution and common sense To prevent injury or accident install the equipment out of the reach of children Ensure that the installation conforms to the regulation in force in the region concerned The filtration box p
6. ctric cables to avoid any electromagnetic disturbance which may distort measurements v Place the second pipe collar at a minimum distance of 50 cm from the first Adjust the opening preferably 1 2 upwards Mark then drill the pipe Mount the injection connector Y joint with Teflon Mount everything on the pipe collar The injection connector should be as close as possible to water pushing in to the pool Connect the suction strainer to the pH pump with a part of the tubing supplied The arrow on the pH pump cover indicates the flow direction v Connect the outlet of the pH pump to the injection connector with a piece of the tubing supplied v Connect the pump to the controller For the disinfectant follow the instructions outlined for the type 1 pump using the colored tubing Type 3 pumps disinfectant pH algaecide v For the disinfectant and pH follow the instructions outlined for the type 2 pumps v For the algaecide follow the instructions outlined for the type 1 pump IV ACTIVATION A INTRODUCTION When installing the device for the first time or at the start of a new season it is imperative to check and adjust the following 3 points v The pool water must be clear and free from algae or sediment v The water should be correctly balanced alkalimetry hydrometry e Alkalimetry shows the level of bicarbonates dissolved in the water e Hydrometry shows the water hardness that is the l
7. d by POOL TECHNOLOGIE Zac des Jasses 115 rue de Oliveraie 34130 Valergues France www pool technologie com 16
8. ee will on no account extend the initial warranty Limit of the warranty Not included in the warranty 1 Equipment and labour provided by a third party at the time of the installation of the equipment 2 Damage caused by an installation which is non compliant 3 Problems caused by deterioration accident harsh treatment professional negligence or by the final user non authorised repairs fire floods lightening frost armed conflict or any other force majeure ATTENTION The warranty does not cover any damaged equipment further to non respect of security use rules use and maintenance stated in the current manual Every year we improve our products and software These new versions are compatible with previous models New versions of equipment and software are not added to the warranty from the previous models 13 Implementation of the warranty v For more information on the current warranty contact your professional or our After Sales Service Any request should be accompanied by a copy of your proof f purchase Y Do not hesitate to activate your guarantee on www pool technologie com It will enable you to receive information on your device v No part replacement will be made without the defective part being returned beforehand Any part which is not returned will be charged at the current tariff Laws and disputes v The present warranty is subject to French law and all other European directives or international treatie
9. evel of calcium or magnesium salts dissolved in the water v The pH of water should be stabilised between 7 0 and 7 2 A The efficiency of a chlorine chemical treatment is rapidly decreased by the increase in pH and scale precipitates more quickly when pH is high or unstable Effecthveness of chlonne 6 ri foe 4 Th F8 HU Source French Ministry of Health B INSTRUCTIONS Model 2 and 3 pumps the pH probe has been calibrated in the factory no calibration needs to be carried out to regulate pH before first using it All models it is necessary to adjust the dose of the disinfectant and or algaecide according to the instructions of paragraph V The activation of your device is now completed We recommend you to activate your guarantee on www pool technologie com It will enable you to receive information on your device V MAINTENANCE A Never use hydrochloric acid Only use a pH corrector product acid or base which is recommended by your professional The use of any other chemical product can lead to irreversible damage to the device It is IMPERATIVE to check the levels of chlorine and pH each week with your usual analysis kit An excessive level of chlorine and or a low pH is likely to cause oxidation of the metal parts and can lead to non reversible deterioration of the pool surface axes and automatic shutter flaps telescopic shelters thermal exchangers If you are covering the pool shutter tarpaulin cover
10. evice If the pH is normal adjust or calibrate the pH probe 2 Flashing AL display The device has detected that the previous attempts to correct pH have not been successful Y Check that the pH corrector tank is not empty v Check that the pH pump is injecting properly cf paragraph V 2 v Check the pH probe comparing the value indicated by the device with the pH measured in the pool with your usual analysis kit v Check the condition of the extraction and injection valves v Check the volume of the pool refer to paragraph V 5 Y Do not hesitate to visit our FAQ on www pool technologie com If you do not find solution to your problem contact our Technical Assistance Service on N INDIGO 0 892 705 520 from France 0 34 TTC MN Please supply v Proof of purchase v Serial number of the controller and the pH probe v Date when the device was installed v Name of the professional shop where it was purchased and or who installed the equipment pH chlorine level water temperature stabiliser level pool volume time of daily filtration VII WINTERING When wintering the pool emptying the pool and or stopping filtration carry out the following maintenance operations v Remove the pH probe and keep it in the rubber protection or filled with tap water v Rinse the flexible tube of the peristaltic pump with clean water Changing the pump tubing Replace the flexible tubing from the peristaltic pump each season the check valves The
11. o adapt the timing to the pre selected method e Choosing the pH corrector The device has a default setting for using an acid corrector product It may be necessary to modify this regulation acid base adapt it to the characteristics of the water in your pool v Press button V for 3 seconds MA flashes in the display vV Select the function Co with the buttons then confirm with V V Select by an acid product AC or base bA then confirm with V The display stops flashing and after 3s the device automatically goes to regulation mode f Regulating pH The pH of the water in the pool is by default automatically regulated around 7 2 It is however possible to modify this point de consigne to adapter it to the characteristics of the water in your pool v Press the V button for 3 seconds MA flashes in the display Y Choose the SE function with the buttons then confirm with V v The display flashes with the stored details v Choose the value you want with within 6 8 to 7 6 then confirm with V pH regulation will from now on be at the new value chosen 11 VII ALARMS 1 Flashing pH displa The device has detected a value of pH gt 1 Alarm pH high or pH lt 1 Alarm pH low Check the value of the pH in the pool using your usual analysis kit If the pH abnormal stop the device Add a pH acid corrector Alarm pH high or pH base Alarm pH low to the pool through the refoulement pipes Restart the d
12. ower supply line should be protected by a differential circuit breaker with a release security of 30 mA maximum with an opening distance of at least 3 mm on all poles This circuit breaker has nothing to do with the house s one from 300 to 500 mA In case of doubt get a qualified electrician to look at the installation The electrical installation of this equipment should be performed by a qualified person in accordance with the regulation in force in the region concerned The power supply cables must be protected against accidental damage A damaged cable should be replaced immediately and exclusively with an original cable Never cut or extend the cables It is important to turn off the power supply before carrying out any technical work Do not modify the device Any modification may cause damage or be dangerous Only qualified personnel should carry out maintenance in case of break down This device is intended for use in family pools only NON OBSERVANCE OF THESE INSTRUCTIONS MAY CAUSE DAMAGE TO THE DEVICE OR SERIOUS INJURY Il PACKING LIST Before starting installation ensure that the box contains _pH probe 5 m colored tubing 10 m tubing 15 m tubing 5 m transparent tubing for pH 10 m transparent tubing for pH 5 m colored tubing for and algicide disinfectant 5 m colored tubing for disinfectant N A 1 pipe collar diam 50 mm x 12 3 pipe collars diam 50 mm x 4 pipe collars diam 50 mm x 1 2 2 II INS
13. rameter to modify flashes Choose the desired value using the buttons then confirm with V The value will flash for 3 secs The device then automatically returns to the default function Button C allows you to stop the operation in progress at any time and return to the main menu Se NR NN NN 1 Start Stop This function allows you to stop or start the device again at any time v Press and hold C for 3 seconds 2 Disinfection or Algaecide Injection of disinfectant takes place every hour according at the dose which the user has set see the disinfectant product user advice to determine the necessary hourly dose Injection of algaecide occurs each time the device is started in a dose which the user has set see the disinfectant product user advice to determine the necessary daily dose a Manual injection This function allows you to carry out manual injection of disinfectant or algaecide for an adjustable amount of time vV Select the function you want then press button V for 3 seconds MA flashes in the display VY Select the MA parameter and confirm with V v 01 is displayed by default or the last saved value in ml vV Select the dose from 0 to 990 ml using the buttons then confirm with V Attention a display of 15 means 150 ml v Injection starts When it is finished after 3secs the device automatically goes into regulation mode b Regulating the dose VY Select the desired function then press b
14. s which are in force at the moment of complaint and which are applicable in France In the event of dispute with regard to its interpretation or its execution this is the remit of TGI de Montpellier 14 IX ENVIRONMENT PRESERVATION Environment preservation is essential Our company is very much involved in this Our products are designed and manufactured with materials and components which are of a high quality respect the environment and are reusable and recyclable However the different components of which they consist may not be biodegradable Our products should not just be discarded European environmental directives set for each product category appropriate methods of managing and disposing of waste material The aim is to reduce waste material and to use it avoid making their components become a danger and to encourage the products to be reused To carry out this policy successfully product manufacturers distributors users and even professionals are involved in managing waste material from these products Since August 13 2005 a European directive means you can dispose of your used product free of charge e If you buy anew product which is more or less the same you can bring it back to the distributor when you are buying a new one e Take it to a waste recycling facility The symbol stamped on a product means that a selective collection is necessary and that it must be sorted from other household waste 15 Manufacture
15. ter 3 secs Stop the filtration Put the probe back into its holder then put filtration to lt AUTO gt mode LN NAA S D If the calibration does not work v The display reads Er for Error Pressing Stop Start or V will clear the message v The previous parameters will be stored v Contact a professional You may need to replace your pH probe The calibration solutions are disposable They can be kept for year in their vacuum sealed packet stored away from light and heat Dispose after use 10 A Never dry the pH probe with a cloth or absorbent paper since it may damage it Leave it to drip dry d Regulating the pool volume This function allows you to adapt the quantity of corrective product injected to the volume of the pool The volume by default corresponds to pools from 30 to 35 m code 15 Press the V button for 3 seconds MA flashes Choose CP using the buttons then confirm with V The display flashes and shows the default value code 15 when first installed Choose the code which corresponds to the volume of the pool using the QO Y buttons then confirm with V The display stops flashing After 3s the device automatically goes to regulatory mode Y VVV WV Sm to6m 06 35m to40m 110 m to 120 m 6m to7 m 7mto8m 08 45m to50m 18 130m t0140m 28 8mto9m 09 Each code represents the injection time for the pH corrector product Due to the nature of water it may be necessary t
16. tomatically goes to regulatory mode NN NRN In case of failure in adjusting the pH probe v The display shows Er for Error Push the button ON OFF or V to erase the message v The previous value is kept v Calibrate the probe c Calibrating the pH probe Each pH probe has its own characteristics To regulate pH satisfactorily it is recommended that a calibration pH probe be made at the start of the season and after any change to the pH probe v Check that you have pH7 and pH10 solutions not supplied vV Stop filtration Remove the probe from its holder and replace it with a coin Then set filtration to MANUAL mode Hold down the V button for 3 seconds MA flashes Choose function CA using the buttons then confirm with V The display shows the 1 point of calibration by flashing 7 Place the pH probe in a standard pH 7 solution then confirm by V Please wait Calibration is automatic the display will flash alternatively 7 and If the measured value is correct the display will read Oh Rinse the pH probe then let it drain After 3 s the display will then show the 2nd calibration point by flashing 10 Place the pH probe in the pH 10 solution then confirm with V Please wait Calibration is automatic the display will flash alternately 10 and If the measured value is acceptable the display will read Oh for 3 s The new parameters are then stored v The device will automatically move into regulation mode af
17. utton V for 3 seconds MA flashes in the display Select the do parameter and confirm with V 00 is displayed as default or the last saved value in ml Select the dose from 0 to 990 ml using the buttons then confirm with V Attention a display of 15 means 150 ml v After 3 secs the device automatically goes to the main menu SSS 3 pH regulation a Manual injection This function allows you to carry out manual injection of a corrector product for an adjustable amount of time Y Select pH regulation function then press button V for 3 seconds MA flashes in the display VY Select the MA parameter and confirm with V 60 flashes by default or the value saved in s Y Select the time desired with the buttons from 0 to 9 5 mins then confirm with V v Injection starts Important over 60 s the read out is in minutes and seconds 1 1 means minute and 10 seconds v After 3secs the device automatically goes to the main menu b Adjusting the pH probe This function allows the display to show the pH value you have measured in your pool with your usual analysis kit Press button V for 3 seconds Ma starts to flash Choose function Ad using the buttons then confirm with V The display flashes the value 7 0 Select the desired value using the buttons then confirm with V If the selected value is acceptable then the display shows Oh during 3 s The new value is then saved v After 3 secs the device au

Download Pdf Manuals