1.  such requests essentially flatten the design hierarchy     e Inthe default mode  with neither FLAT nor BY CELL specified  the polygon  output may contain polygons belonging to a cell in two ways     o Ifa netin the cell violates ERC Pathchk requirements in some placements  of this cell  the polygons are written out for each placement where the  violation occurs in top level coordinates     o If  for a given net  a violation appears in every placement of a cell  the  polygons are written out once  in the lowest  leftmost placement     This can lead to confusion because  in the same cell  some polygons may be  displayed in many placements and others in only one placement  If the results are  difficult to interpret  the BY CELL option can be useful     The FLAT option can also be used to force Calibre to output cell specific results in all  placements  This increases both memory consumption and the size of the polygon  file  but can eliminate potential confusion caused by hierarchical output  However   output using the NETS option is unambiguous in all cases     ERC Pathchk statements are not executed if the specified net is not present  For  example  if there is no power net in the layout  then ERC PATHCHK   POWER  generates an error message and generates no output     Results Output Options  The output files are readable by RVE similar to a DRC Results Database     POLYGONS     The POLYGONS option specifies a file   named  ayout_primary pathchk erc  It is placed in the Mask S
2.  top level connectivity  Text Layer  text objects that are power and or  ground net labels to be present  Possible choices are     POWER     Reports nets with a path to a power net      POWER     Reports nets with no path to a power net    GROUND     Reports nets with a path to a ground net      GROUND     Reports nets with no path to a ground net   Where the exclamation mark     is synonymous with Boolean NOT     The labeled_flag and the power_ground_flag keywords  when not connected by  an operand  are called primitive conditions    e operand  An optional string of logical symbols that combine two primitive conditions  Possible  choices are      amp  amp      Selects nets that satisfy both primitive conditions  Boolean AND            Select nets that satisfy the first or second primitive condition  or both   Boolean OR   e POLYGONS NETS   POLYGONS   NETS  Specifies the type of results file to output  Possible choices are     POLYGONS     Generates an Calibre nmDRC results database in ASCII format that  contains the polygon output of all nets that satisfy the specified conditions     NETS     Generates a text file that contains a list of all nets that satisfy the specified  conditions     Both are specified by default     e BY LAYER  BY CELL   FLAT     An optional keyword set that specifies the type of output to include in the  generated ASCII results file  These pertain to the POLYGONS option only  Possible  choices are     BY LAYER     Generates a separate check for each l
3. ERC Pathchk    Specification statement    Reports nets in the layout that do or do not have a path to power  ground or  labeled nets  or that satisfy a combination of these conditions  Used during circuit  extraction in Calibre nmLVS  Calibre nmLVS H  and ICtrace Mask mode     Note                This statement is provided primarily for backward compatibility  The Pathchk layer stat  conducting ERC checks                    Usage    ERC PATHCHK   labeled_flag   power_ground_flag  operand power_ground_flag     POLYGONS NETS   POLYGONS   NETS    BY LAYER   BY CELL   FLAT    PORTS ALSO   NOFLOAT   EXCLUDE UNUSED    EXCLUDE SUPPLY        Parameters    e labeled_flag    A required string that specifies how the tool reports a net that does or does not  have a path to a top level labeled net  This option requires top level connectivity   Text Layer  text objects that are neither power nor ground net labels to be  present  Possible choices are     LABELED     Reports nets with a path to a labeled  Text Layer  net     LABELED     Reports nets with no path to any labeled  Text Layer  net     where the exclamation mark     is synonymous with Boolean NOT   A labeled_flag may not be specified with a power_ground_flag        power_ground_flag    A required string that specifies how the tool reports a net that does or does not  have a path to a top level supply net  Power and ground nets are top level nets  specified in the LVS Power Name and LVS Ground Name statement  This option  requires
4. VDB Directory if that  statement is specified  otherwise in the current working directory    If Jayout_primary is not specified  the word lvs is used instead  The file consists of  lines in the format     ERC PATHCHK condition   in cell cell_name     layer_name      where condition is the specified condition  such as   POWER or   POWER  amp  amp   GROUND  By default  results from each ERC Pathchk statement are written to one  check in the result file  If the BY CELL option is specified  then the results are  classified by cell and the ce  _name field indicates the cell name  If the BY LAYER  option is specified  then the results are classified by layer and the  Jayer_name field  indicates the layer  Empty checks are not written  If all checks are empty  no file is  created     All polygon results are shown in the top level coordinate space  and they are  written to a Calibre nmDRC results database in ASCII format  By default   hierarchical Calibre shows cell specific results only once in a representative  placement of the cell  The lowest  leftmost placement of each cell serves as its  representative  This is similar to Calibre nmDRC H  Results are cell specific if they  can be generated locally in the cell and occur in all placements of the cell in the  design     Note that polygon results generated by ERC Pathchk are not fully merged  This  means that polygons can abut or overlap     NETS     The NETS option specifies a file named  ayout_primary pathchk rep  It is  placed i
5. XCLUDE SUPPLY  An optional keyword that instructs the tool to exclude power and ground nets from  the results of an ERC Pathchk request containing at least one of the   keywords POWER or GROUND  not preceded by the   operator   Supply nets are  included if EXCLUDE SUPPLY is not specified     Description    Reports nets in the layout that do  or do not  have a path to top level power and or  ground nets  or labeled nets     By default  a path is any route that leads through source drain pins of built in MOS  devices or pos neg pins of built in resistor devices  To qualify  a MOS device  types  M  ME  MD  MN  MP  or any of the LDD type devices  must have at least the  following pins  G  or gate   S  or source   and D  or drain   Paths through LDD type  devices are formed in both directions  Capacitor  diode  or bipolar devices can also  be added to the path  as specified in ERC Path Also statements     If you want to enable user defined devices to participate in ERC Pathchk  user   defined devices do not participate by default   then you must map these devices  and their pins to built in devices and pins  This is done using the LVS Device   Type specification statement  See    User Defined Devices in Path Check Operations     in the Calibre Verification User   s Manual     Power and ground nets are specified with LVS Power Name and LVS Ground  Name specification statements  respectively  This statement utilizes wildcard  characters that appear in LVS Power Name and LVS Ground N
6. ame specification  statements  Power and ground nets break paths     The hierarchical level from which text objects are read is controlled by the Text  Depth statement     Power and ground nets are included in the result for the  keywords POWER and GROUND  For example  supply nets are included if you  specify     ERC PATHCHK POWER    You can exclude supply nets by specifying EXCLUDE SUPPLY  When specifying  EXCLUDE SUPPLY  at least one of the POWER or GROUND keywords must also be  specified in the statement   The EXCLUDE SUPPLY keyword does not apply to   the   POWER or   GROUND keywords   For example     ERC PATHCHK POWER  amp  amp    GROUND EXCLUDE SUPPLY    is allowed  However  this form causes a compiler error     ERC PATHCHK   POWER  amp  amp    GROUND EXCLUDE SUPPLY    bad  syntax    Power and ground nets are not included in the result for   POWER and    GROUND keywords  The supply net itself is not selected even if there is no path  from power to ground  For example     ERC PATHCHK   GROUND    If a net in the design matches more than one of LVS Power Name or LVS Ground  Name name patterns  a warning is issued and conflicts are resolved with power  names being given priority over ground names     The LABELED nets are those with connectivity extraction  Text Layer  text  but  they are not power or ground nets     By default  nets that are labeled by port objects alone  no Text Layer objects  are  not output  The PORTS ALSO option changes this behavior  All objects from n
7. ayer  If both BY CELL and BY  LAYER are specified  a check is generated for each layer in each cell  Empty checks  are not generated     BY CELL     Causes each cell that has cell specific results to be checked separately   The check contains nets reported in that cell  The results are reported in top level  coordinate space  BY CELL is ignored in flat execution     FLAT     Causes cell specific results to be replicated in every placement  FLAT has  no effect in flat execution    e PORTS ALSO  An optional keyword that specifies to output polygons on nets that are connected  only to port objects  nets having Text Layer objects on them are not included   By  default  such nets are not included in the output for any request  The PORTS ALSO  option removes the special treatment of port nets  This option affects both  POLYGONS and NETS output  Note that port objects are specified with the Port  Layer Text in Calibre  and the  make_port   command in Pyxis Layout     e NOFLOAT  An optional keyword that instructs the statement to ignore floating nets  Floating  nets are nets that are not connected to any devices    e EXCLUDE UNUSED    An optional keyword that instructs the statement to exclude unused nets from the  ERC Pathchk output  Unused nets are connected only to unused devices  Unused  devices are specified with LVS Filter Unused Option or equivalent LVS Filter Unused    statements  All options for LVS Filter Unused Option are supported except the INV   P  and Q options     e E
8. ets  connected to top level nets named by port objects alone are output     ERC Pathchk statements respect the LVS Compare Case statement  If either the  LVS Compare Case YES or LVS Compare Case NAMES statement is specified  then  power names and ground names are traced in a case sensitive manner  otherwise  they are case insensitive  These rules on case sensitivity apply to LVS Power Name  and LVS Ground Name nets     ERC Pathchk observes the Layout Preserve Case specification statement for case   sensitivity of net names  See    Case Sensitivity of Supply Net Names    in the Calibre  Verification User   s Manual for more details     This statement applies to Calibre nmLVS Calibre nmLVS H and ICtrace Mask mode   It is executed during circuit extraction and only when the layout is geometric  The  following Calibre commands execute this statement              calibre  lvs rules    executed flat  calibre  lvs  tl     rules    executed flat  calibre  lvs  hier     rules    executed hierarchically with             geometric Layout System  calibre  spice     rules    The following Pyxis Layout commands execute this statement     Slvs_mask      executed flat  Swrite_mask_cnet       executed flat                Note the following important considerations     e The POWER  GROUND  and LABELED options  without the   operator  are  not recommended because they can generate very large files  consume large  amounts of memory  and lead to long runtimes  In particular  in hierarchical  ERC 
9. n     Calibre issues the warning in both the transcript and the circuit extraction report     This limit applies only to polygon output  for example during the construction of a  result layer and when performing the POLYGONS option     Calibre always completes the net reporting part of this functionality  including the  functionality resulting from the NETS option     You should not reach this limit in normal operations  You see it only in  circumstances when a very large net is selected by the ERC Pathchk statement     See also ERC Summary Report  The search features Find Path and Isolate Path on  Layout Net in Calibre RVE for LVS may also be of interest     Examples    Example 1    The following statement outputs a text file listing all the nets with a path to a  labeled net     ERC PATHCHK LABELED NETS                   Example 2  When not using the       LABELED option  the following combinations are possible     POWER  amp  amp  GROUND  Nets with no path to power but with a path to ground      GROUND  amp  amp  POWER  Nets with no path to ground but with a path to power      GROUND  amp  amp    POWER  Nets with no path to ground and no path to power      GROUND      POWER  Nets with no path to ground or no path to power  or both     POWER  amp  amp  GROUND  Nets with a path to both power and ground    POWER    GROUND  Nets with path to power or a path to ground    
10. n the SVDB directory by default  otherwise in the current working directory   Iflayout_primary is not specified  the word lvs is used instead     In hierarchical execution  the report file format is this           ERC PATHCHK REPORT for layout_primary  ERC PATHCHK condition   cell cell_name  placement   netl  net2   cell cell_name  placement   netl  net2              where condition is the specified condition  such as GROUND AND     POWER  cell_name is a cell name where results were found  placement is a  representative placement of that cell  and net  is a net name or number  Cells are  listed in bottom up order  Net names and numbers are in the context of the  indicated cells  Cells for which no nets are found by ERC Pathchk are not written to  the report file     In flat execution  the report file format is     ERC PATHCHK REPORT for layout_primary  ERC PATHCHK condition   netl  net2        Nothing is reported for requests in which no nets are found in any cell  If all checks  are empty  no file is created     Requirements and Restrictions    Hierarchical Calibre operations impose a size limit on intermediate data structures  generated by ERC Pathchk  The limit is approximately 400 MB  This limit is applied  independently to each individual ERC Pathchk statement  Calibre generates  incomplete results  some polygons may be omitted from the output  and issues the  following warning if Calibre reaches this limit        WARNING  ERC operation exhausted allowed memory allocatio
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Questionnaire de Sensibilisation au Bon Usage des AVK dans les  株式会社 キクチ科学研究所 スプリングローラー型スクリーン 外観詳細図 SBSR  取扱説明書 MD(669KB  Manuale tecnico  Catálogo Instrumentos de medición de pH testo  Operating Instructions Spare Parts List  Philips LX9000R/25S Home Theater System User Manual  agendaculturel - Mairie d`Aix-en  Samsung Galaxy Tab (10.1) User Manual  SkyLink EQ User's Manual    Copyright © All rights reserved. 