Home
Chapter 1 - Champtek
Contents
1. 2 2 44 5 Chapter 2 Installation sse 7 2 1 UNPACKING U X IER ena dE pared 8 2 2 CONNECTING 424 01 10 2 3 ADJUSTING iieii iaia 11 2 4 POWERING eee rai 12 2 5 INITIALIZING 22 20 13 Chapter 3 Using LIBRA nano arn conc ccnnrccn nr ranancnnn 15 3 1 SCANNING BARCODES nn 16 3 2 CONTROLLING lac 17 3 3 MAINTAINING 2 024441 17 Chapter 4 Applications Heel 18 4 1 LIBRA AS A CORE MODULE OF YOUR APPLICATION SOLUTIONS19 APPENDICES ERO u X u um iu a dod tae 22 A CONNECTOR TYPES AND PIN DEFINITIONS 22 B TECHNICAL 5 24 C 2 2 008 26 Preface Scantech ID LIBRA is a high performance multi interface and omni directional scanner The unit comes with powerful reading sensitivity which allows hands free bar code scanning Bar code labels are read by presenting the label towards the scanner Scanning labels with LIBRA hardly requires any arm movement LIBRA reads all popular bar code symbologies An important feature of LIBRA is its auto sense mode If the scanner is not used withi
2. scanner is installed as described in Chapter 2 and that all cables are properly connected Problem Diagnostic Tips The scanner is on but a barcode e The scanner window is dirty Clean cannot be read the scanner window as described in section 3 3 e The presented barcode type is not enabled Select the barcode type with the Configuration Guide e The scanner is disabled by the host Refer to section 3 2 e The barcode type you presented to the scanner is not supported by LIBRA The scanner does not accept more e There is no proper handshaking with than two or three barcodes the host system Switch the host system on and check connection and communication settings A barcode is read by the scanner e The communication cable is not but not accepted by the host connected to the serial port of your system host system Refer to the manual of your host system to locate the serial port e The communication settings of the host and scanner do not match Ensure that the setting values for both devices are the same For proper adjustment values refer to the Configuration Guide e The communication cable does not suit your host system Contact your supplier for the correct communication cable LIBRA L 7050 27 The data format is not supported by the software running on the host system USB communication is not working In case of KB emulation you can select various keyboard language
3. ING LIBRA requires little maintenance Only occasional cleaning of the scanner window is necessary to remove dirt and fingerprints Cleaning can be performed during operation with a non abrasive glass spray cleaner and a soft lint free cloth NOTE Please contact your dealer for specific cleaning material Chapter 4 Applications 20 Applications 4 1 LIBRA AS A CORE MODULE OF YOUR APPLICATION SOLUTIONS Barcodes have become a distinguishing mark of modern civilization The familiar stripes are popping up almost everywhere in everyday life Libraries retail stores supermarkets post offices bill payment for services law firms shipping companies enterprises distributors manufacturers hospitals etc The benefits of bar coding are obvious improved data accuracy and accessibility enable a company to make correct decisions about future needs and actions Consequently profits are up Case Benefits of Bar Coding for Retail Stores e Building a competitive infrastructure e Synchronizing supply with demand e Creating high profitability e Trimming operational costs Appendices A Connection Types and Pin Definitions B Technical Specifications C Troubleshooting 22 Appendices A CONNECTOR TYPES AND PIN DEFINITIONS LIBRA supports multiple interface RS232 KBW Keyboard Wedge USB and Powered USB The various pin definitions for each type of interface are given below IMPORTANT Various interface cabl
4. ack and adjust the angle as shown below Front angle 22 max Back angle 80 max 12 Installation 2 4 POWERING LIBRA is designed to use a single cable for both data transmission and power supply This requires that your host system can provide sufficient power on its data port RS232 KBW or USB Power injector Some applicable LIBRA interface cables have a power injector to connect an external power supply in case the host system cannot supply sufficient power for the scanner 5 V AC adapter Cable Power injector RS232 Keyboard Wedge y Powered USB USB x Though some cables have a power injector this does not mean that you must use a power supply For safety reasons an automatic switch will disconnect the power provided by the host system as soon as a separate power adapter is connected to the power injector Changeable power plugs To change the power plug suited to your area follow the steps below 1 Press and hold the tab on the AC power adapter 2 Remove the changeable plug outwards Y 3 Replace with the desired power plug LIBRA L 7050 13 2 5 INITIALIZING When using LIBRA for the first time you need to initialize the communication parameters first Follow the steps below to initialize 1 Ensure that the desired interface cable is connected to LIBRA and your host system 2 Power up LIBRA 3 Initialize the communication parameters by scanning the programming b
5. arcode 1 1 and 1 3 on the Configuration Guide NOTE The procedure is required only once However when changing the cable from one type to another you need to perform the procedure again KBW mode In KBW Keyboard Wedge mode the scanner defaults to the International Keyboard layout ALT method for communication NOTE To change the settings to national keyboards in KBW mode refer to section 3 4 on the Configuration Guide RS232 mode In RS232 mode the default communication parameters are 9600 N 8 2 Using the Scantech ID Configuration Guide you may select one of the various presets or set each parameter by hand USB mode In USB mode the scanner defaults to Keyboard Emulation Mode LIBRA transmits the data in International Keyboard layout ALT method for communication NOTE The LIBRA USB must be directly connected to the host USB port and not through an un powered USB hub 14 Installation Other available USB communication selections are e USB IBM fixed POS scanner e USB IBM handheld scanner emulation e USB COM port emulation NOTE See section 3 5 USB communication on the Configuration Guide for more information Chapter 3 Using LIBRA 16 Using LIBRA 3 1 SCANNING BARCODES LIBRA is an omni directional presentation scanner featuring a 6 directional scan field with a 24 line scan pattern Barcode labels can easily be read by presenting them to the scanner NOTE Si
6. cable to a class lla laser product Avoid long term viewing of direct laser light SCANTECH ID BV The Netherlands PN XXXXXXXXXXXXXXX IIAII I IIII IIW III SN XXXXXXXXXXXX SW XXXXXXXX Made in Taiwan A The information about the serial and part numbers can be found on the product label These official registration numbers are strictly related to the device The supplier may ask for these numbers when the scanner needs servicing Chapter 2 Installation 8 Installation 2 1 UNPACKING Your package comes with the following items Scanning unit packed by plastic bag EPE packing foam AC adapter set for RS 232 model only Configuration Guide Ol OO N Interface Cable NOTE If anything is missing or appears to be damaged immediately contact your dealer You can mount LIBRA without the fit plate but the plate may be suitable for your special mounting requirements Contact your dealer for more information Store the original packaging box Use it to transport LIBRA for future servicing LIBRA L 7050 Exterior View Item Name Description Lights to indicate the scanner status 1 LED e Blue Standby mode ready to read e Orange Successful read Window Reads the bar code placed in front of the window Buzzer Beeps when data is read correctly Cable hook Use to align the cable NOTE LIBRA beeps whenever da
7. d Up to 230 mm 0 33mm 13mil PCS 90 Code39 Resolution 4mil 0 1mm PCS 30 Scan pattern 6 direction scan field 24 lines scan pattern Scan rate 2 000 scans per second Light level Up to 4 800 LUX EAS EAS compatible standard Barcode types Automatically discriminates standard 1D bar codes include GS1 Databar family Omnidirectional Omnidirectional stacked Expanded Expanded stacked Truncated and Limited Scan pattern 10 cm LIBRA L 7050 25 Physical Characteristics Depth 97 71 mm 3 84 inches Width 85 mm 3 35 inches scanner 94 mm 3 70 inches base Height 161 51 mm 6 36 inches Weight 350g 12 355oz Color available Black Scanner Base or Beige scanner Dark Grey base 97 71 69 83 161 51 Environmental Operating Temperature 0 C 40 C Storage Temperature 20 60 C Humidity 5 95 RH non condensing dew Laser Safety Class IEC60825 1 U S 21CFR1040 Class lla Electrical Safety EN 60950 1 2001 EM Compatibility Radio and TV Interference EN 55024 22 FCC Part 15 class B CNS 13438 Electro Static Discharge IEC 801 2 1991 ESD 26 Appendices C TROUBLESHOOTING This section contains information on solving problems you may encounter when using the scanner If troubles occur take a moment to read the information in this section However before referring to the diagnostic tips ensure that the
8. e revision or change A serial number appears on the product Make sure that this official registration number has not been removed It should be used whenever servicing by Scantech ID BV or an authorized Scantech dealer is necessary Important This equipm ent has been tested and found to comply with the limits for a Class B digital device pursuant to EN55022 and with the limits for a class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipm ent is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user s manual may cause harmful interference to radio communications Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any unauthorized changes or m odifications to this equipment could void the user s authority to operate this equipment For CE countries LIBRA is in conformity with the CE standards Please note that a Scantech CE marked power supply unit should be used to conform to these standards V5 0 Aug 2014 iii Table of contents ae ie 1 Chapter 1 Product 2 2 2 3 1 1 LASER SAFETY u u u e 4 1 2 DECLARATION OF
9. es are available depending on the kind of host system you are using Contact your supplier for availability In case you need a special purpose cable you can refer to the information below The Connector type of LIBRA RJ 48 10 pins Pin Definition for multiple interface Multiple Interface USB or RS 232 KBW Powered USB Pin Description Description Description Remark 1 IFID IFID Interface ID 2 CTS PC Clock 3 RxD PC Data 4 TxD KB Data IFID Interface ID 5 RTS KB Clock 6 Ground Ground Ground Ground 7 45V 45V 45V py May De u to power scanner 8 16V DC input to 8 D Power D Power D Power power scanner 9 I IFID connect D IFID Interface to 6 T ID D USB 10 D D USB data LIBRA only requires one single DC input LIBRA L 7050 23 Pin definition EAS connector ESA Pin Description Direction 1 C 2 I You can pull the EAS rubber cap out as shown below and can find the two Pins of the internal deactivation antenna which can be connected to an external EAS control unit EAS wired rubber cap 24 Appendices B TECHNICAL SPECIFICATIONS DC input to scanner 5 V DC 250 mA Power output Operating Power Standby Power 1 7 Watt 5 V DC DC 5 V 340mA typical DC 5 V 270mA typical Light source Scanner Characteristics 650 nm visible laser diode Depth of fiel
10. f A Y AA A ON N Da E EF fF NY SCANTECH ID SS Installation amp User s Manual Scantech ID LIBRA L 7050 Multi purpose Omni directional Scanner N Installation amp User s Manual Scantech ID LIBRA L 7050 Multi purpose Omni directional scanner Copyright 2010 Scantech ID BV This manual is copyrighted with all rights reserved Under the copyright laws this manual may not in whole or in part be copied photocopied reproduced translated or converted to any electronic medium or machine readable form without prior written consent of Scantech ID BV Limited Warranty Under all circumstances this manual should be read attentively before installing and or using the product In no event shall Scantech ID BV be liable for any direct indirect special consequential or incidental damages arising out of the use or inability to use this docum entation or product even if advised of the possibility of such dam ages In particular Scantech ID BV shall not be liable for any hardware software or data that is stored or used with the product including the cost of repairing replacing or recovering the above Scantech ID BV reserves the right to change parts of the device at any time without preceding or direct announcem ent to the client Scantech ID BV reserves the right to revise this m anual and to make changes in the contents without obligation to notify any person or entity of th
11. n a programmable period of time the scanner switches off automatically The scanner can be reactivated by placing a barcode towards the window of the LIBRA LIBRA is designed with a specific size for all kinds of store applications and ideal to use in check out services Features Integrability The compact design allows the unit to be mounted with ease on a host system with minimum space requirement Quality and Durability e The components are of top quality and the case is solid moist and dust resistant All of these secure a long and service free operation time e Durable characteristic with IP42 rating and drop resistance with cable e Automatic sleep and wake up mode which saves power and improves life time Flexibility and Connectivity The multiple connection interfaces RS232 Keyboard Wedge USB and Powered USB allow the unit to communicate with the host system with considerable flexibility Decoding Capability e barcode decoding capability is up to date including GS1 DataBar and all major 1D barcode symbologies e The Scantech ID STAR reconstruction software enables the reading of fragmented and damaged barcodes 2 About this manual This manual contains four chapters and three appendices e The first chapter provides the product safety information The second chapter describes LIBRA s general features and installation The third and forth chapters account for the use of LIBRA e The connector types a
12. nce LIBRA is a presentation scanner best results are obtained if the barcode is moved towards the scanner LIBRA s scan volume is illustrated in the figure below The scan depth varies depending on the size of the barcode Barcode minimum element 0 127mm 5mil code39 0 15mm 6mil code39 0 26mm 10mil EAN 0 33mm 13mil EAN 100mm 200mm 300mm 400 90 PCS Performance may be impacted by bar code quality and environmental conditions Resolutione DOF 0 127mm Smil Code39 50 90mm 1 96 3 54 inch 0 15mm 6mil Code39 50 100mm 1 96 3 93 inche 0 26mm 10mil 50 220mm 1 96 8 66 inch 0 33mm 13mil 50 230mm 1 96 9 06 inch LIBRA L 7050 17 3 2 CONTROLLING LIBRA can be controlled from the POS PC system via the RS232 interface or via USB while using comport emulation Control is achieved by transmitting single byte commands to the scanner The following commands are available ASCII code Function Byte is also called 05 Hex Power up re initialization ENQ or lt Ctrl E gt OE Hex Enable cancels disable Shift Out or lt Ctrl N gt OF Hex Disable Shift In or lt Ctrl O gt 12 Hex Sleep DC2 or Ctrl R 14 Hex Wake cancels sleep DC4 or lt Ctrl T gt POS system NOTE More commands are available upon request Please contact your dealer for more information 3 3 MAINTAIN
13. nd pin definitions technical specifications and troubleshooting can be found in the appendices Chapter 1 Product Safety 4 Product Safety 1 1 LASER SAFETY English LIBRA scanner complies with safety standard IEC60825 1 2001 for a Class laser product It also complies with U S 21CFR1040 as applicable to a Class lla laser product Avoid long term viewing of direct laser light Optical The use of optical instruments with this product will increase eye hazard Optical instruments include binoculars microscopes and magnifying glasses but do not include eye glasses worn by the user Radiant Energy LIBRA uses a low power laser diode operating at 650 nm in an opto mechanical scanner resulting in less than 0 6 mW peak output power Laser light observed at 13 cm 5 1 in above the window through a 7 mm 0 28 in aperture and averaged over 1000 seconds is less than 3 9 uW per CDRH Class lla specification Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8 mW could be accessible inside Laser Light Viewer The scanner window is the only aperture through which laser light may be observed on this product A failure of the scanner motor while the laser diode continues to emit a laser beam may cause emission levels to exceed those for safe operation The scanner has safeguards to prevent this occurrence If however a stationary laser beam is emitted the faili
14. ng scanner should be disconnected from its power source immediately Adjustments Do not attempt any adjustments to or alteration of this product Do not remove the scanner s protective housing There are no user serviceable parts inside WARNING Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure LIBRA L 7050 1 2 DECLARATION OF CONFORMITY Scantech ID B V Scantech ID BV Vanadiumweg 22 3821PZ Amersfoort The Netherlands Tel 31 0 33 4698400 Fax 31 0 33 4650615 Hereby declares under our sole responsibility that the product Product LIBRA Model number L 7050 and equivalent Product View Will comply with the following product specifications Laser Safety IEC60825 1 CFR 1040 Class lla CDRH Electrical Safety EN 60950 1 2001 EMC EN 55022 2006 A1 2007 EN 61000 3 1 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EN 55024 1998 A1 2001 A2 2003 Please note that a Scantech ID CE marked power supply unit should be used to confirm the product specifications stated above CE FCC BSMI and RoHs compliant 6 Product Safety SCANNER LABELING The product label and the laser safety label are on the back and the side of LIBRA as indicated in the illustration below All labels are attached by the manufacturer and should not be removed IEC825 class 1 laser product Complies with 21 CFR1040 as appli
15. s or the universal Alt input method default You may want to try programming barcodes from section 3 4 on the Configuration Guide In case of KB emulation in combination with the Alt input method check that Num Lock of your keyboard is on In MS windows environment verify with the device manager that the HID Human Interface Device is installed for the scanner Check that the scanner and the host system both expect the same USB protocol KB emulation RS232 emulation or IBM POS protocol See the Configuration Guide for setup codes and reset the scanner after making any changes When using a standard USB cable the scanner defaults to the USB KB emulation protocol with ALT method character transmission When using USB plus power cable with the green connector the scanner defaults to USB IBM POS protocol for tabletop scanners These settings are restored after programming back to default using the Configuration Guide Due to Champtek s Scantech ID s continuing product improvement programs specifications and features are subject to change without notice SCANTECH ID a Champtek company Scantech ID BV Vanadiumweg 22 3812 PZ Amersfoort The Netherlands Phone 31 0 33 469 84 00 Fax 31 0 33 465 06 15 Email info scantech id com Internet www scantech id com Internet www champtek com
16. ta is read correctly Both frequency and volume can be adjusted see section 2 1 1 Speaker frequency and 2 1 2 Speaker volume on the Configuration Guide 10 Installation 2 2 CONNECTING Interface Selection LIBRA allows you to connect your host system using four different interface cables RS232 Keyboard Wedge USB and Powered USB On powering up the scanner determines the type of the interface used and switches to the appropriate protocol Interface Cable Connector type RS232 Product Number 0114 SM01121 Sub D 9 pin St Keyboard Wedge Product Number 0114 SM02121 Standard PS2 USB Product Number 0114 SM04121 USB connector USB Cable 1 5M 3M optional Aa Ea Powered USB Powered USB Product Number 0114 S801121 connector pamm c n LIBRA L 7050 11 Changing the interface cables By default a USB cable is already attached to LIBRA upon receiving it To change the interface connection follow the steps below 1 Hold the LIBRA upside down 2 Remove the attached cable 3 Connect the desired interface cable to LIBRA Wall hooks 4 Align the cable through the cable hook 5 Connect the other end of the interface cable to your host system 6 If necessary mount the scanner on the wall using the wall hooks 2 3 ADJUSTING LIBRA s angle can be adjusted To do this hold LIBRA by its b
Download Pdf Manuals
Related Search
Related Contents
User Manual - LaserTouchOne Manuel d`utilisation des ordinateurs de poche Palm™ de la série Handset self diagnostics Motorola MU350R Two-Way Radio User Manual Gebrauchsanweisung für Kühl-Gefrier Zanussi ZEV6940FBA hob Manual de Usuario NOTARIOS Copyright © All rights reserved.
Failed to retrieve file