1. JP5A HO Hibyte Midbyte i JPS ADDR MOD S2 S1 H SHT STD un JP1 JP2 U27 U26 U25 U24 8 8 88 DEBUG B DEBUG A P4 ROBOT A ROBOT B Figure 1 Component locations 3 2 IACKOUT Jumper TACKIN and IACKOUT are daisy chained interrupt acknowledge signals specified in the VMEbus specification IACKOUT is hardwired through the card to IACKIN Therefore it is irrelevant whether the IACKIN IACKOUT jumper has been removed or not from the VME backplane pins A21 and A22 for the particular slot into which the TRC005 is inserted There is no jumper on the TRCO05 to configure IACKOUT 3 3 Address Space Selection The TRC005 can be addressed in either short 16 bit I O space or standard 24 bit memory space using supervisory or non privileged accesses There are a total of four different address modifier codes that the TRCO05 can respond to in the following combinations Address Modifier Codes Type of Access 2D only Short supervisory I O access 3D only Standard supervisory data access 2D or 29 Short supervisory or short non privileged I O access 3D or 39 Standard supervisory or standard non privileged data access Selection of the address size short or standard is determined by the position of jumper JP2 To select short addressing position JP2 over the center and left pins when viewing the board with the VME connector P1 at the top To select standard addressing position JP2 over the center and right pins when v
2. debugging aid is provided as an option to help monitor data flow to and from the TRC004 boards This option consists only of two seven segment LED s for each robot channel that display hexadecimal values The two displays latch data bits 0 3 and 8 11 for every access read or write to their respective TRC004 Bits 0 3 appear on U24 for robot A and U26 for robot B Bits 8 11 appear on U25 for robot A and U27 for robot B It is important to note that these LED s cannot be used to monitor general bus traffic They only latch data within the address space of the TRCOOS The displays can be turned on or off by switch 9 of switch block S2 When the switch is in the ON position the displays are on To reduce power consumption it is recommended that they remain off during normal operation TRC005 User s Manual Page 6 5 0 Troubleshooting 5 1 Problem Resolution The following represent a few common errors that may prevent normal operation of the board set This is not an exhaustive list of problems nor is it an exhaustive list of solutions for these problems Use of the debug option if installed can help determine if proper accesses are occurring on the VME bus and if the proper data is being sent to the TRC004 Problem Board does not respond to reads or writes Solution See next problem Problem Bus error occurs when attempting to read or write Solution 1 DIP switches and or jumpers are incorrectly set See section 3 2 DIP switches a
3. The DTACK jumper JP3 belongs in position 4 and should not be moved 3 6 Watchdog Timer The watchdog timer requires no configuration Its time out interval is fixed at the factory at between 20 and 100 milliseconds Connections are made with a miniature phone plug to J1 for robot A and J2 for robot B The phone jacks connect to both contacts of an SPST relay These contacts are electrically isolated from the TRCOO5 and the TRC004 The contacts are closed during normal operation when the timer is constantly reset The contacts open when write operations stop and the timer is allowed to time out The relay contacts of the watchdog timer are intended for low current operation Under no circumstances should the current through the relay contacts exceed 1 amp 3 7 Connections to TRC005 A 50 conductor ribbon cable connects the TRCOO5 to each of its associated TRC004 s This cable should be no longer than 3 meters There are no other connections between the TRC004 and TRCOOS The two watchdog timers have separate miniature phone jacks The SPST contacts of the TRC005 User s Manual Page 5 watchdog relay are connected to both terminals For operation with a PUMA robot connect the relay contacts in series with the arm power port See PUMA documentation 4 0 Operations 4 1 General Information To a host computer the TRC004 is characterized as a block of 16 bit memory locations as described in the TRC004 User s Manual These locations res
4. The information in this document is subject to change without notice Trident Robotics and Research Inc does not guarantee the accuracy of the information contained in this document and makes no commitment to keep it up to date Trident Robotics and Research Inc makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose This device is not intended for use in medical support equipment and should not be used in any application where intermittent malfunction or failure may directly jeopardize the health or well being of an individual or individuals Address comments concerning this document to Trident Robotics and Research Inc User Documentation Department 2516 Matterhorn Drive Wexford PA 15090 7962 412 934 8348 SlotSavr is a trademark of Trident Robotics and Research Inc PUMA is a trademark of Unimation Inc Unimate is a registered trademark of Unimation Inc Revised November 1993 TRC005 User s Manual Page i Contents 10 Introduccion ssl tri srt lis TET 2 1 1 General Informatica aiii 2 ZO PEC AL ONS dido 2 NOTAS AO A IA EA E LE E 2 3 1 General Information eaae a n a a a A a A E A A 2 3 2 IACKOUT Jumper vns darian 3 3 3 a A Vans in ann a E cae A SESER 3 3 4 Base Address Selection srn a en ae aiea ai EAA Eea E OR ES EANES 4 Oro DTFACK MP a a E a E E Sa 5 3 6 Watchdog TIMET ssivssecassescavessccissavevadnso
5. ect address bits A16 through A23 respectively only when standard accesses are selected as described in section 3 2 Sliding a switch toward the word on printed on the switch block selects the on position which corresponds to a logic zero 0 for the TRC005 User s Manual Page 4 respective address bit The remaining address bits AO through A6 select the appropriate board and register A6 selects robot A when logic zero 0 and robot B when logic one 1 Al through A5 are decoded by the selected TRC004 board These bits multiplex the desired word length register onto the data bus as determined by the TRC004 memory map Bit AO is not decoded at all therefore ALL ACCESSES MUST BE WORD LENGTH AND WORD ALIGNED NOTE THE TRC005 ONLY RESPONDS TO WORD 16 BIT ACCESSES Figure 4 shows example settings of S1 and S2 for a base address of OxFF5100 In this example robot A would respond to accesses in the range 0xFF5100 OxFF513E while robot B would respond to accesses in the range OxFF5140 OxFF517E The debug option switch S2 9 is off It is important to note that the entire address range OxFF5100 OxFF517E is consumed regardless of the number of TRC004 cards actually attached to the TRC005 Any word access to this range will generate a DTACK pulse from the TRC005 HIBYTE MIDBYTE 654321 H OFF 1 987 2a86B8BH8 ON B 0N 0 S2 S1 Figure 4 Example base address OxFF5100 3 5 DTACK Jumper
6. ia des pinin ter EEEa aa E iaaa ena 5 3 7 Connections to TRCO0S ooooonnnnnnnccnnnnnnnnononnnonenonoccccncncnnnnnnnnnnnnnnnonanaonnncnnoss 5 BAY COS A A O A ON 6 4 1 General Information cccccncnnnncnonncnnnnnnnnnnnononononcnnnnnnnnnnnnronoconnnnnnnnnnnnananinisos 6 4 2 Reads and WiiteS amianto das adds 6 4 3 Watchdog Timer its tas 6 A O aavsens 6 5 0 Troubleshooting oeiia ressaire saer erani a TOSS voce ad SEa Ee ra e erasi 7 SI Problem Resolution anita 7 3 2 a o Support rira A suis a e a gen Abas esas ase e A etna 7 GO SChematics A A AA 7i TRC005 User s Manual Page 1 Trident Robotics and Research Inc TRC005 VMEbus Interface Card A Member of the SlotSavr Family of Control Peripherals 1 0 Introduction 1 1 General Information The TRCO005 is a member of the SlotSavr family of control peripherals Its unique design allows for the connection of multiple input output I O cards to a single slot in the host backplane It is a VMEbus address decoder card designed specifically for use with the TRC004 1 O card It provides address decoding and bus buffering for up to two TRC004 s In addition it provides two watchdog timer circuits that automatically open if the respective TRC004 is not addressed for writing every 20 milliseconds This provides a safety feature to de energize power circuits in the event that the real time control hardware or software crashes The TRC004 also manufactured by Trident Robotics is a general
7. ide on 16 bit boundaries from the BASE address THE TRC004 DOES NOT EXAMINE ADDRESS BIT AO LSB FOR ADDRESS DECODING Therefore all data transfers through the TRCOOS must be word size and must be word aligned The TRC005 is transparent to this operation except for the establishing of the BASE address and the address modifier 4 2 Reads and Writes All reads and writes to and from the two TRC004 s occur within their specified address space subject to the selection of BASE address and address modifier as described in section 3 All accesses must be word size and word aligned 8 bit and 32 bit accesses are ignored 4 3 Watchdog Timer Two watchdog timers are installed on the TRCOOS Each timer operates independently of the other and is reset by any write to the 32 word address space of its corresponding TRC004 channel The timer controls a relay the SPST contacts of which are connected to the miniature phone jack on the card panel If the timer is not reset at least every 20 milliseconds this number may range from 20 100 milliseconds the timer opens the relay This relay can switch a maximum of amp The LED s D2 and D4 indicate the status of the respective watchdog relays for robots A and B When the LED is illuminated the relay is closed NOTE WRITE ACCESSES OCCURRING WITH A PERIOD SLIGHTLY LONGER THAN THE TIME OUT PERIOD WILL MAKE THE LED APPEAR TO BE ILLUMINATED WHEN IN FACT IT IS FLASHING AT THE ACCESS RATE 4 4 Debug Option A
8. iewing the board in the same orientation These jumper positions are illustrated in figure 2 TRC005 User s Manual Page 3 JP2 JP2 Short Addressing Standard Addressing Figure 2 JP2 jumper positions for short and standard addressing To select the appropriate address modifier codes install or remove jumpers on JP1 Jumpers on JP1 must only be installed vertically when viewing the board with the VME connector P1 at the top in positions AM2 or AM4 Figure 3 details these positions and orientations Any other orientation is invalid and may cause unpredictable operation Address modifier AM codes are selected according to Table 1 The default configuration will respond to AM codes 3D or 39 standard supervisory or non privileged data access memory space JP1 ZN NI ee O NI A AM2 Position Y N e Ol AM4 Position amp Figure 3 Jumper positions for JP1 AM Code Jumper AM2 Jumper AM4 2D only OUT IN 3D only OUT OUT 2D or 29 IN IN 3D or 39 IN OUT Table 1 Selecting address modifier codes 3 4 Base Address Selection The 128 byte window for the two robots can be arbitrarily located anywhere within the chosen 16 bit or 24 bit address space by adjusting the DIP switches of S1 and S2 Switches 1 through 9 of switch block S1 select address bits A7 through A15 respectively Switches 1 through 8 of switch block S2 sel
9. purpose interface board for servo applications It provides eight channels of buffered analog output eight channels of analog input six quadrature shaft encoder channels six bits of discrete input and six bits of open collector discrete output It is designed to be located physically close to the analog circuits it is controlling so it requires a separate bus interface card to sit on the real time bus VMEbus in the case of the TRC005 and perform address decoding and bus buffering functions 2 0 Specifications The TRCOOS is addressable in either short I O space 16 bit address or standard memory space 24 bit address No interrupt support is provided One or two TRC004 cards can be connected to a single TRCOOS and each occupies adjacent and contiguous 32 word 64 byte blocks of the space The base address of the TRCO05 is fully user selectable via DIP switches IACKOUT is hardwired through the card 3 0 Installation 3 1 General Information The TRC005 is transparent from a software standpoint There are no configuration registers that affect its operation All configuration is done by means of jumpers and DIP switches which are described below It s only purpose is to provide a base address for the memory map of the TRC004 s The locations of components important to the user are shown in figure 1 NOTE NEVER INSTALL OR REMOVE A CARD FROM A VME CHASSIS WITH POWER APPLIED TRC005 User s Manual Page 2 JP5B oo RISE FALL
10. re not fully seated in position Flip them back and forth 3 Invalid access mode Accesses must be 16 bits wide and must match the address modifier codes selected See section 3 4 DTACK jumper JP3 or JP4 is missing Problem Values read from TRCO004 appear noisy Solution Cable to TRC004 from P3 or P4 is too long Cable must not exceed 3 meters Problem Debug LED s U24 U27 are not present Solution Debug option was not ordered Call Trident Robotics to order Problem Debug LED s U24 U27 do not illuminate Solution Switch S2 9 is not on or is not fully seated in the ON position Flip switch to ON position or rapidly flip switch off and on Problem When used with PUMA robot arm power does not come on Solution Watchdog timer has timed out or arm power port is not connected correctly A write to the TRCOOS must occur approximately every 20 milliseconds to keep the watchdog energized 5 2 Technical Support If you are not able to resolve a problem yourself note the serial numbers and model numbers including any revision letters of all Trident products involved and contact technical support at 412 934 8348 If this application involves a PUMA robot also note the manufacturing date and model number from the side of the Unimate controller 6 0 Schematics Complete schematics of the TRC005 follow TRC005 User s Manual Page 7