1. Pattern Number Back Displays the pattern number value options are 001 004 Note There can be as many as 4 patterns recorded each no more than 3 minutes The dome camera can pan from one left point to right point and then pan back NOTE Camera pans only 22 XSD27ZIR Record Select to Record a pattern The following menu will pop up Call Preset 1 To Confirm X 100 The user can operate the dome with pan tilt zoom movements as needed The system will record the pattern of movement To end recording user can call preset 1 to confirm and save the recording Test Select to Test the recorded pattern Run Select to run the Pattern until another command is received Back Select to go back to the upper level menu i ZONE Main Menu gt Auto Running gt Zone Zone Number 001 Title 000000000000000 Left Limit Right Limit Remove Current Pan Speed 001 Run Back A zone is an area between two points The user can set a zone and scan it automatically Zone is similar to Cruise except that the user can assign a title for a ZONE Whenever the camera moves into the zone the title will display on the screen to alert the operator NOTE Camera scans horizontally only User can set up to 8 zones Zone Number Displays current zone number Values can range from 001 008 Move the joystick right th
2. If the backlight is too dark the object on the center of the picture may appear dark So backlight compensation can decrease the brightness of the object Select BLC MODE and the editing menu will pop up 000 Disables backlight compensation function 001 255 Choose a different backlight compensation level The greater the value means more backlight compensation will be set BLC Level 000 Back XSD27ZIR vision PAN TILT PARAMETERS MI PAN TILT MENU OPTIONS Main Menu gt lt Pan Tilt gt Auto Stop Time Off Speed Amplify Off Proportional P T Off Set North Back M AUTO STOP TIME Main Menu gt lt Pan Tilt gt gt Auto Stop Time For some particular protocols the dome will not stop moving even there is no operation on joystick This menu item sets the time after which the dome receives last control command Off Disables this function default setting 001 255 The time unit 50ms after which the speed dome will stop moving without receiving any commands SPEED AMPLIFY Main Menu gt Pan Tilt gt Speed Amplify gt Some protocols controlling speed is much lower set Speed Amplify to accelerate the speed dome s movement Options are as below Off Disable this function default setting 01x 32x x Times greater than the original speed 20 lI PROPORTIONAL P T Main Menu gt lt Pan Tilt gt gt Proportional P T gt
3. Main menu System gt gt Password Input Password Confirm pum PSWD Protection On Back Input Password Move the joystick right to enter submenu Old Password Back Old Password gt Enter the old password Back gt If old password is correct cursor goes back behind Input Password so that new password can be inputted If old Password is not correct cursor goes back to Input Password Password cannot be changed in this case Confirm When and only when the new password is entered can the user get to this menu If the password is not the same as entered the first time it remains unchanged lt PSWD Protection Password protection can be switched on and off When it is On user need to enter password to access main menu or save preset through the keyboard NOTE The dome s default password is 123456 Contact the supplier for the master password if the password is forgotten after changing it Select BACK to return to upper menu BI SET DEFAUT Main Menu gt System Info 2 Set Default Select Set Default to restore factory default settings List of Default Settings Item Default Value Zoom Speed High AI AF Resume Mode Both AF Resume Time 005 AF Resume Time 005 Iris ALC 084 Iris PIC 016 Day Night Auto all display config Off Fram
4. ON ON ON ON 82 ON ON ON 32 ON 83 ON ON ON ON 33 ON ON 84 ON ON ON 34 ON ON 85 ON ON ON ON 35 ON ON ON 86 ON ON ON ON 36 ON ON 87 ON ON ON ON ON 37 ON ON ON 88 ON ON ON 38 ON ON ON 89 ON ON ON ON 39 ON ON ON ON 90 ON ON ON ON 40 ON ON 91 ON ON ON ON ON 41 ON ON ON 92 ON ON ON ON 42 ON ON ON 93 ON ON ON ON ON 43 ON ON ON ON 94 ON ON ON ON ON 44 ON ON ON 95 ON ON ON ON ON ON 45 ON ON ON ON 96 ON TON 46 ON ON ON ON 97 TON ON TON 47 ON ON ON ON ON 98 ON ON TON 48 ON ON 99 ON ON ON ON 49 ON ON ON 100 ON ON ON 50 ON ON ON 101 ON ON ON ON 1 ON ON ON ON 102 ON ON ON ON E E CN E M M EN NE ON ON ON ON ON ON ON ON 26 ision X XSD27ZIR B8 ON B7 ON B6 ON B5 ON ON ON ON ON ON B4 ON ON ON ON ON ON B3 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON B2 B1 ON ID 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 19
5. Run auto scan 001 004 Tour 001 004 Run tour 001 004 Pat 001 004 Run pattern 001 004 Preset Tour Pattern Cruise Zone Park Time 010 Park Action Pat 001 Back In this example the system will run Preset 8 after 38 seconds of idle time 23 XSD27ZIR APPENDIX I DIP SWITCH SETTINGS This is the guide for setting protocol baud rate dome address video cable type and resistor jumper DIP Switch position The corresponding Dip Switch positions are shown below E Protocol and Baud Rate setting SW1 is for protocol and baud rate settings Bits 1 6 of SW1 are for protocol setting and bits 7 8 are for baud rate setting as shown in the chart below Default setting is 4800 bps vision Protocol Switch Number 3 4 5 6 ERNITEC YAAN ALEC ON PELCO_PD ON PELCO C ON VCL ON MOLYNX ON ON VICON ON ON DIAMOND KALATEL HUNDA ON LILIN ON SANTACHI ON PELCO_PDC ON UNIVISIONV1 ON ON UNIVISIONV2 ON ON OOOO O O AD ON Switch Digits Baud Rate o2 ex 1 2 3 6 4 5 ADT ON PANASONIC ON ON PHILIPS ON 7 2400 OFF 4800 ON 9600 OFF 19200 ON 2 25 5 o H Reset Button This button is for resetting the dome after changing th
6. 0 216 0 0 0 0 240 0 0 0 0 217 ON 0 0 0 0 241 ON 0 0 0 0 218 ON 0 0 0 0 242 ON 0 0 0 0 219 ON ON 0 0 0 0 243 ON ON 0 0 0 0 220 ON O 0 0 0 244 ON 0 0 0 0 221 ON ON O 0 0 0 245 ON ON 0 0 0 0 222 ON ON O 0 0 0 246 ON ON 0 0 0 0 223 ON ON ON O 0 0 0 247 ON ON ON 0 0 0 0 224 ON O 0 248 ON O 0 0 0 225 ON ON O 0 249 ON ON O 0 0 0 226 ON ON O 0 250 ON ON O 0 0 0 227 ON ON ON O 0 251 ON ON ON O 0 0 0 228 ON ON O 0 252 ON ON O 0 0 0 229 ON ON ON O 0 253 ON ON ON O 0 0 0 230 ON ON ON O 0 254 ON ON ON O 0 0 0 jos ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 28 XSD27ZIR Resistor Jumper Setting RS485 bus needs two 120 Ohm resistors at both ends Set the 120 Ohm resistors of the two devices keyboard or dome at the farthest distance on RS485 bus The default setting is OFF e wision When choosing the first and second pins in 2 the 120 Ohm termination resistor is connected When choosing the second and third pins in 2 the termination resistor is unconnected 29 XSD27ZIR e wision APPENDIX II WIRE DIAMETER amp TRANSMISSION CHART The transmission distances listed below are the farthest ones recommended for each given wire diameter when the 24V AC voltage loss ratio is below 10 for equipment powered by AC the maximum vo
7. The dome moves at a speed of certain degree per second Objects on screen move much faster in wide scope than in tele scope Even too faster in some case This function decreases the dome movement speed while zooming in On Enable default setting Off Disables this function M SET NORTH lt Main Menu gt gt lt Pan Tilt gt gt lt Set North gt User can set orientation on screen by using joystick to position north Back Select to go back to the main menu NOTE It is recommended that the camera is set to geographic north XSD27ZIR vision AUTO RUNNING MI AUTO RUNNING MENU OPTIONS lt Main Menu gt gt lt Auto Running gt Preset Tour Pattern Cruise Zone Park Time Off Park Action Off Back M PRESET Main Menu gt Auto Running gt lt Preset gt Preset Number 001 Title PRE1 Set Current Test Current Test Next Remove Current Back Preset is the point that user save for frequent use A preset saves both direction and zoom parameter the camera will quickly and precisely go and zoom to a specific point if a preset is called E g If you often want to watch the door you can set the point of door as a preset then you can quickly monitor the door simply by calling the preset NOTE 220 presets can be set Preset No Displays the current preset number The value ranges from 001 to 220 Move the joystick u
8. eirean r serren 15 Reset Button SSS 24 Changing Items 15 LEDGE SESS iit 24 Editing Titles nnm 15 Dome Address Setting eere 25 SYSTEM MENU 16 Address Setting Chart m 26 System Menu Options m m 16 Resistor Jumper Setting m 29 Site info 16 Display Setup emen 16 APPENDIX II WIRE DIAMETER amp o MRNA 9 TRANSMISSION CHART e 30 idee dete 17 APPENDIX Ill R 485 BUS BASIC KNOWLEDGE n 31 at Detalles esoo 17 APPENDIX IV TROUBLE SHOOTING 32 System Reboot eene 17 APPENDIX V LIGHTNING amp SURGE PROTECTION 33 LENS PARAMETERS 18 APPENDIX VI WARRANTY ecer 34 Joystick AF Al nnnnnnnnnnnnnnnn 18 AF Resume Time mnn 18 Al Resume Time nnn 18 Day Night pee 18 XSD27ZIR FEATURES Product Features vision Day Night Camera with 18x SRLEDs for an IR Multiple RS485 protocols range of 60m On Screen Display can be customized to suit user Offers High Resolution 550 600 TVL images OSD Menu for Programmable Functions Sleek design for professional applications Variable Cruise Speed 0 1 150 sec Cable Managed Bracket for external wall mounting Variable Pan Tilt Speed Features System Preheat for use in low Vertical Tilt Unobstructed 0 to 90 temperature environments Auto Running Memory Against Power Outage Programmable Multi protocol Features Auto Running for
9. for outdoor environment This speed dome runs on 24V AC Connect to power only after completing installation Disassemble can only be carried out by qualified personnel Use soft towel to clean the down cover when necessary Avoid using caustic detergent Avoid aiming camera to strong light XSD27ZIR INSTALLATION PREPARATION TOOL LIST Following tools may be needed for the installation 1 Screws and nuts 2 Philips screw driver 3 Standard screw driver 4 Wire scissors 5 Ladder 6 Drill 7 Saw CABLING 8 Video Coaxial Cable 9 759 impedance 10 Solid copper wire 11 95 braided copper shield Check the max transmission distance referring to the chart below Cable Type Distance RG 59 U 750ft 229m RG 6 U 4 000ft 305m RG 16 U 1 5000ft 457m 12 RS485 Cable 13 0 56mm 24AWG twisted pair wire DIP SWITCH SETTING See Appendix I 14 Protocol and Baud rate 15 Dome address 16 Video cable type 17 Resistor jumper vision XSD27ZIR vision WALL MOUNT supplied POLE MOUNT optional accessory AS CORNER MOUNT optional accessory PENDANT MOUNT optional accessory XSD27ZIR vision INSTALLATION GUIDE WALL MOUNT Check to make sure the wall surface is firm and does not flake off The wall must be able to withstand 8 times weight of the dome and its fixtures 1 Mark mounting position 2 Install bracket Use br
10. when the system is idle 360 continuous Pan 180 Tilt Auto Flip On Screen display for compass and tilt angle 220 presets 0 1 preset accuracy System and environment temperature amp fan status 300 Pan Tilt Preset Speed Designed for external wall mounting as supplied Canrecord up to 4 tours each with up to 27 Pole Mount Pendant Ceiling Mount and Corner presets points Mount brackets also available Supports up to 4 patterns 4 cruises 8 titled zones which can be set to specific requirements Password Protection Power 24V AC Input Power Power Consumption 10VA Heater OFF Built in surge protection 45VA Heater ON Limited lighting protection Fuse 1 25A Operating Temperature Model Absolute Max Sustained Max Absolute Min Sustained Min XSD27ZIR 140 F 60 C 122 50 C 60 F 51 C 50 F 45 C Note 1 Assume no wind chill factor 2 Prevents icing at sustained minimum of 50 F 45 C 3 De ices 0 1 inch 2 5 mm within 3 hours after power up XSD27ZIR TECHNICAL SPECIFICATIONS vision Image Sensor 1 4 Super HAD Image Resolution 550 600 TVL Lens 3 9 to 105 3mm Zoom 27x Zoom Speed 3 9 to 6 3 seconds Angle of View 1 to 60 Sync system Internal external Min Illumination 0 Lux with IR on S N Ratio gt 48db Iris Auto Manual White Balance Auto Manual Gain Auto AE Control Au
11. 4 195 196 197 198 199 200 201 202 203 204 205 206 Soft Add B8 B7 ON B6 ON B5 B4 ON ON ON ON B3 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON B2 B1 ON ID 03 04 05 06 07 08 09 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 Soft Add 27 XSD27ZIR ID B1 B2 B3 B4 B5 Bo B7 B8 ID B1 B2 B3 B4 B5 B6 B7 B8 207 ON ON ON ON 0 0 231 ON ON ON 0 0 0 208 0 0 0 232 0 0 0 0 209 ON 0 0 0 233 ON 0 0 0 0 210 ON 0 0 0 234 ON 0 0 0 0 211 ON ON 0 0 0 235 ON ON 0 0 0 0 212 ON 0 0 0 236 ON O 0 0 0 213 ON ON 0 0 0 237 ON ON O 0 0 0 214 ON ON 0 0 0 238 ON ON O 0 0 0 215 ON ON ON 0 0 0 239 ON ON ON O 0 0
12. In the main menu the cursor flashes on the left side Move the joystick up or down to point to the desired item Then move the joystick right to select the item Select an item to enter its sub menu or run a specific function or change its value or edit its title W CHANGING VALUES Move the joystick up or down to change the value move the joystick left to save the setting and exit In the case of multiple digits value move left or right to select digits move up or down to change value move left to save the setting and exit Note To increase the value changing speed hold the joystick up or down for more than 10 seconds For example In order to change BLC LEVEL please follow these steps 1 Call preset 95 or call preset 1 twice within 5 seconds to access the Main Menu System Lens Camera Pan Tilt Auto Running Exit 15 Camera move the joystick right to select it Select BLC MODE in the same way White Blance Auto BLC Mode Back NOTE In this manual menu paths are written in the following format Main Menu gt Camera gt 2 BLC Mode gt lt BLC Level 3 The BLC Level option blinks Move the joystick up or down to change the option move the joystick left to save the changing BLC Level 000 Back When finished select Back to return to upper menu XSD27ZIR vision SYSTEM MENU BI SYSTEM MENU OPTIONS Main Menu gt System g
13. NOWLEDGE 1 Basic Property RS485 Bus is specified by RS485 standards It is of half duplex data transmission cables with characteristic impedance as 120 The maximum load capacity is 32 effective loads including main controller and controlled equipment 2 Transmission Distance For 0 56mm 24AWG twisted pair wires as data transmission cable the maximum theoretical transmitting distances are as follows Baud Rate Max Transmit Distance 2400BPS 1200m 4800BPS 1000m 9600BPS 800m With thinner cables installation of the dome in an environment with strong electromagnetic interference or a large number of equipment connected to the RS485 Bus the maximum transmitting distance will be decreased 3 Connection and termination resistor 3 1 The RS485 standards require a daisy chain connection between the equipment There must be termination resistors with 120 Ohm impedance at both ends of the connection refer to following pictures Please refer to following picture for simple connection D should not exceed 7 metres TN YY VY eU B 31 4 Best Practice In some circumstances a star configuration connection is required The termination resistors must be connected to the two equipment that are farthest away from each other such as equipment 14 and 15 in the following diagram As the star configuration is not in conformity with the requirements of RS485 standards problems such as si
14. Names of the interfaces are marked on the terminal block eo em or Connect cables as shown in the diagram Make sure oa M e power is off before connecting AC24V GND AC24V 485 485 VIDEO VIDEO tooo 10 XSD27ZIR 6 Install black liner and Pan Tilt Module e Please inseret flat wire into socket strongly and be sure to be locked Please be sure that the connection between flat control wire and socket on base is fixed mPENDENT MOUNT vision 7 Install down cover Unscrew the two M4 screw on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws NOTE Apply lube to the O ring for external mounting For low ceiling installations dome can be mounted directly into the base flange 1 Mark the mounting position Use the bracket base to mark the fastener positions on ceiling 3 Install suspender Feed the cabling through the cavity of suspender and then turn the threaded pipe head into the bracket base and fasten the connection with a M5 screw NOTE Apply waterproof tape to the thread and put silica gel to the suspender for external mounting A Li L et 2 Install base Feed the cabling through the central hole of the bracket base and then fix it on ceiling NOTE Put silica gel along the top of bracket base for external mounting uc Silica Gel lt jn 4 Install housing Feed cables through the top
15. XSD27ZIR Day Night 550 600 TVL IR Speed Dome Camera with 27x Optical Zoom 50 Metres IR Night Vision amp Power Supply USER MANUAL e wision Please rea d this manual before you install or start using the XSD27ZIR Speed Dome XSD27ZIR fision CONTENTS FEATURES misessa ep intr retener rere 3 CAMERA PARAMETERS nnns 19 DECLARATION 4 White Balance rmn 19 seen etes 4 BLC MOE sissies 19 Warnings ene 4 PAN TIET PARAMETERS 2n tn tnnt 20 INSTALLATION PREPARATION nnn 5 Auto Stop Time mnn 20 Tool Listener tent rns 5 Speed Amplify nnn 20 Cables secet tree 5 Proportional P T enn 20 Dip Switch Setting A E 5 Set North MH 20 MOUNT TYPE aan 6 AUTO RUNNING SSN 21 INSTALLATION GUIDE siint rre 7 pt IH 21 Wall erret ttr et 7 TOUS eruere 21 Corner 8 22 Pole MOUNT 10 Pattern I 22 Pendent Mount nnn 11 Tone rindo 23 SYSTEM CONNECTION nnn 13 Park Tim ert ttti tnn 23 OPERATION INSTRUCTION nnn 14 Park Action enn 23 Preheating Screen 14 Boot up Screen eem ene 14 APPENDIX I DIP SWITCH SETTING HARI 24 Access Main Menu nnn 14 Dip Switch Position m n 24 MENU OPERATION eodeni ertet 15 Protocol and Baud Rate Setting 24 Selecting
16. acket to mark the mounting position on wall Feed all cables through the hole of bracket and fix the bracket MUST on the wall s 3 Install housing 4 Set dome ID baud rate and protocol Feed the cables through the hole on top of the housing Set dome ID bard rate and protocol by configuring DIP switches Align the dome casing to the bracket and fix with 2 M5 see APPENDIX I screws as shown NOTE Remove the packing sponges NOTE Apply water proof tape to the thread when mounting externally M5 Screw Tane Thread m T 5 Connect cables E us ea Plug cables into corresponding sockets on circuit board Reinstall 00 N the circuit board and turn on the power Turn off the power after rad IEIET on JE checking me ee o e 000000 e NOTE Names of the interfaces are marked on the terminal block E or PCB Connect cables as shown in the diagram Make sure power is off before connecting C24V GND AC24V 485 485 VIDEO VIDEO XSD27ZIR vision 6 Install black liner and Pan Tilt Module 7 Install down cover Unscrew the two M4 screw on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws NOTE Apply lube to the O ring for external mounting Please inseret flat wire into Socket strongly and be sure to be locked Please be sure that
17. ber Values can be set to 001 004 lt Dwell gt Sets the default dwell time in seconds for each preset Values can range from 0 99 seconds For example DEFAULT DWELL 001 all presets dwell time is set as 1 second but user can still set independent dwell times for each preset in the Edit menu XSD27ZIR Cision lt Edit gt NOTE If the speed dome has been zoomed in and Edit presets and corresponding dwell times in a tour as lt Cruise gt is selected the camera will keep that zoom follows throughout the camera s movement The speed dome has a maximum of 4 cruise lines Preset Dwell 001 001 002 004 003 002 004 001 000 001 000 001 lt Cruise Number gt o ae COR Displays the current auto scan number The value can 000 001 000 001 000 001 be set to 001 004 Move the joystick right then up or 000 001 000 001 000 001 inn 000 00 down to select values 000 001 000 001 000 001 000 001 000 001 000 001 lt Left Position S Select to set the position of site A The followi Cancel And Back elect to set the position of site A The following menu will pop up The format for the information is displayed as Preset number Dwell time Call Preset 1 To Confirm For example 003 02 means go to preset 003 and dwell for 2 seconds Move joystick left or right to select editing item Move up or down to change the value Move the camera to the desired position and call preset 1 to save In the above
18. e dipswitch setting The new setting works only after reboot finishes LEDs The flashing Green light means the control commands have reached the dome The Red light is on when effective command is received This Speed Dome supports multi protocol The settings are shown in the chart opposite 24 Reserved4 Reserved5 Reserved6 Reserved7 Reserved8 Reserved9 Reserved10 Reserved11 Reserved12 Reserved13 Reserved14 Reserved 15 XSD27ZIR Dome Address Setting The control commands contain target dome s ID The dome only reacts to the command sent to its own address or broadcast address Each dome should be assigned an address Four kinds of IDs are applicable for domes 1 Hard ID Hard ID is set via DIP SW2 cannot be changed from OSD menu Hard ID ranges from 1 to 254 2 Programmable ID Set all 8bits of SW2 to ON to activate soft address Input 10 bit camera SN number and then set dome ID by controller The dome SN number can be found on the side of the camera or on the package and user manual 3 Broadcast ID The Broadcast ID is programmable When the broadcast ID is available all domes connected to the control bus will react to the command The default broadcast ID is 255 4 SW2 ID SW2 is for Dome ID setting The setting is strictly according to binary system If you are not familiar with binary syst
19. e Limit 1 25 Shutter Off Exposure Off White Balance Auto BLC Level 000 Speed Amplify Off Proportional P T On Pswd Protection Off Park Time Off Park Action Off Arm Disarm Disarm Reset Delay 004 IBI SYSTEM REBOOT Main Menu gt System gt System Reboot Select System Reboot to reboot the dome Settings will not change after restarting 17 XSD27ZIR vision LENS PARAMETERS MENU lI LEN MENU OPTIONS AI RESUME TIME Main Menu gt Lens Joystick AF AI Both AF Resume Time Off Light goes through the iris and reaches the CCD to form RM an image A larger iris lets more light go through and a Resume 00 the image will be brighter The Iris can be controlled Day Night Auto automatically or manually For manual operation detail Back please refer to keyboard or matrix manual Off Never restore auto iris after switch to manual 001 255 The dome will start Auto Iris this number of B JOYSTICK AF AI seconds after user manually adjusts the iris Main Menu gt Lens gt Joystick AF Al gt B DAY NIGHT Main Menu gt Lens AI Resume Time Set automatic restore mode When the joystick moves Main Menu gt Lens gt lt Day Night gt the selected function will be triggered Set the dome color mono chrome switching mode Options are Color mode is suitable to work in daytime because it needs higher illumination Both Joystick movement triggers bot
20. e is no AC power connected to the PCB Board There is a power outage or problem of the transformer Camera module is not correctly connected Output Voltage of transformer is too low The power board is not working Check the power connection and outlet make sure they are working properly Check power supply and transformer to see is they are working properly Check all power related cable Examine the power on the dome side making sure it is above 16V Self test is ok but dome cannot be controlled Wrong dip switch setting Control cable reversely connected or disconnected Set the dip switch correctly according to operation manual Check the control cable making sure it is correctly and firmly connected Fan speed under 1000 rpm Fan not firmly connected Connect fan correctly If speed is still under 1000 rpm please contact dealer to replace the fan Blurred picture Dome in manual focus mode or bubble is stained Set focus to auto mode Clear the bubble 32 XSD27ZIR amp wisiori APPENDIX V LIGHTNING amp SURGE PROTECTION The product features TVS lightning proof technology to prevent from damage by lightning strike below 1500W and impulse signals such as surge It is necessary to abide by the following precautions to ensure electrical safety based on practical circumstances 1 Keep the communication cables at least 50 meters away from high voltage equipme
21. em please look up the address setting chart shown on the next page 25 vision XSD27ZIR amp wisiori 4 Address setting chart ID B1 B2 B3 B4 B5 B6 B7 B8 ID B1 B2 B3 B4 B5 B6 B7 B8 1 ON 52 ON ON ON 2 ON 53 ON ON ON ON 3 ON ON 54 ON ON ON ON 4 ON 55 ON ON ON ON ON 5 ON ON 56 ON ON ON 6 ON ON 57 ON ON ON ON 7 ON ON ON 58 ON ON ON ON 8 ON 59 ON ON ON ON ON 9 ON ON 60 ON ON ON ON 0 ON ON 61 ON ON ON ON ON 11 ON ON ON 62 ON ON ON ON ON 2 ON ON 63 ON ON ON ON ON ON 13 ON ON ON 64 ON 14 ON ON ON 65 ON ON 5 ON ON ON ON 66 ON ON 16 ON 67 ON ON ON 7 ON ON 68 ON ON 8 ON ON 69 ON ON ON 19 ON ON ON 70 ON ON ON 20 ON ON 71 ON ON ON ON 21 ON ON ON 72 ON ON 22 ON ON ON 73 ON ON ON 23 ON ON ON ON 74 ON ON ON 24 ON ON 75 ON ON ON ON 25 ON ON ON 76 ON ON ON 26 ON ON ON 77 ON ON ON ON 27 ON ON ON ON 78 ON ON ON ON 28 ON ON ON 79 ON ON ON ON ON 29 ON ON ON ON 30 ON ON 30 ON ON ON ON 81 ON ON ON 31 ON
22. en up or down to select desired value Title Select to set the zone title Left Limit Right Limit Set the position of the first and second point The following menu will pop up vision Call Preset 1 To Confirm Move to the desired point and call preset 1 to confirm Pan Speed gt Select to set the pan speed camera movement speed Values can range from 001 to 255 the greater number represents the higher speed Move the joystick right to select then up or down to change value Run Select to start scanning the current zone set Back Select to go back to the upper level menu M PARK TIME Main Menu gt Auto Running gt Park Time This function lets the system automatically run an assigned function after a specific period of idle time For example if the dome is running a tour and an operator breaks the tour to do other work the dome can automatically carry on the tour within a period of time after the operator stops the break Park time is a period of idle time without any operation Off Disable this function 001 255 Auto runs the Park Action after this number of seconds of idle time MI PARK ACTION Main Menu gt Auto Running gt Park Action Park action refers to the function that system will automatically run when park time is up Off Disable this function Pre 001 220 Call preset 001 220 Scan 001 004
23. example the tour starts from preset 1 dwells for 1 second then goes to preset 2 dwell for 5 Right Position seconds then preset 3 for 2 seconds and finally preset Select to set the position of site B Set it in the same 4 for 1 second way as Left Position Save and Back Save the tour and exit Cruise Speed Cancel and Back gt Quit without saving s as Select to set the scanning speed camera movement speed Values can be set ranging from 001 to 255 the greater number represents the higher speed Move joystick right to select up or down to change the value NOTE When a preset dwell time is set 0 system will skip that preset System will consider preset 0 as the end of a tour Run NOTE No delete function applied to tour edit it again Start the current auto scan 001 004 to replace the previous data cr Back Select to run the current tour once Use this function to SEES cota check the tour M PATTERN Run Main Menu gt Auto Running Pattern Select to run the current tour continuously The system will loop the tour N Number 001 Back lis Select to go Back to the upper menu Sek M CRUISE Pattern is a replay of recorded irregular pan tilt zoom movements It is useful when repeating variable speed Main Menu gt Auto Running Cruise movement of the pan tilt zoom Cruise Number 001 Left Position Right Position
24. gnal reflections lower anti interference performance arise when the cables are long in the connection The reliability of control signals is decreased with the phenomena that the dome does not respond to or just responds at intervals to the controller or does continuous operation without stop refer to following picture gt 32 b er Ir 164 5 RS485 Troubleshooting Trouble Possible Cause Solution 1 The address and baud 1 Change the address rate settings of dome and and baud rate of the controller do not controller or dome Dome can do match 2 Correct the self testing 2 The and connection connection but cannot be of RS485 cable is 3 Make sure the controlled incorrect connections are fully 3 Wiring is not fully connected connected 4 Try using a new or 4 There is break in the shorter length of RS485 cable RS485 cable 1 The RS485 cable is not fully connected 1 Secure the 2 The wire on the RS485 connection The dome cable is broken 2 Replace RS485 cable can be 3 The dome is very far 3 Add termination controlled but away from controller resistors to the system the operation 05485 is not smooth There are too many ja domes connected in the system XSD27ZIR APPENDIX IV TROUBLE SHOOTING vision Problem Cause Solution No movements no video after power on Red LED on circuit board is off Ther
25. h auto Light sensitivity of mono mode is much higher It is focus and auto iris default suitable to work at night without illumination but the Focus Joystick movement triggers auto focus only video is black and white Iris Joystick movement triggers auto iris only None Joystick movement triggers none of the functions lt Auto gt The dome will automatically change modes according to the environment illumination Default setting AF RESUME TIME s Main Menu gt Lens gt AF Resume time gt The dome will always be in monochrome mode System defaults to Auto Focus mode which NOTE Iris ALC Iris PLC Day Night works only for automatically adjusts the focus to get the clear image limited model of camera module Please check Focus can also be manually controlled by keyboard or specification matrix For manual operation details please refer to keyboard or matrix operation manual This item sets the time to restore auto focus after focus is manually changed The default setting is 005 Off Never restore auto focus after switch to manual 001 255 The dome will start auto focus this number of seconds after user manually adjusts the focus NOTE The camera may not be able to auto focus in the following circumstances Target is not in the center of image Near and far targets in the same picture cannot be both clear Target is a strong light object Such as spotlight etc Target is behi
26. hole of the housing and then turn the housing thread pipe head into suspender and fasten the connection with two M5 screws NOTE Apply waterproof tape to the thread for external moutning If installation height is not high enough mount housing directly into the base XSD27ZIR 5 Set dome ID baud rate and protocol Set dome ID bard rate and protocol by configuring DIP Switches see APPENDIX I NOTE Remove the packing sponges 6 Connect cables Plug cables into corresponding sockets on circuit board Reinstall the circuit board and turn on the power Turn off the power after checking NOTE Names of the interfaces are marked on terminal block or PCB Connect cables as picture shows Make sure power is off before connecting 7 Install black liner and Pan Tilt Module Please inseret flat wire into Socket strongly and be sure to be locked Please be sure that the connection between flat control wire and socket on base is fixed gs An 485 485 VIDEO VIDEO vision AC24V GND AC24 8 Install down cover Unscrew the two M4 screws on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws NOTE Apply the lube to the O ring in the case of outdoor dome Lube XSD27ZIR amp wisiori SYSTEM CONNECTION syboard Monitor XSD27ZIR vision OPERATION INSTRUCTIONS The Speed Dome can be controlled through combination of hot key
27. ltage loss ratio allowed is 10 For example a set of equipment with nominal power as 80VA installed 35 feet 10m away from transformer needs a wire with a minimum diameter of 0 8000mm Minimum Diameter of Wire mm Nominal Power VA 0 8000 1 000 1 250 2 000 10 283 ft 86m 451 ft 137m 716 ft 218m 1811 ft 551 m 20 141 ft 42m 225 ft 68m 358 ft 109m 905 ft 275 m 30 94 ft 28m 150 ft 45m 238 ft 72m 603 ft 183m 40 70 ft 21m 112 ft 34m 179 ft 54m 452 ft 137 m 50 56 ft 17m 90 ft 27m 143 ft 43m 362 ft 110m 60 47 ft 14m 75 ft 22m 119 ft 36m 301 ft 91m 70 40 ft 12m 64 ft 19m 102 ft 31m 258 ft 78 m 80 35 ft 10m 56 ft 17m 89 ft 27m 226 ft 68m 90 31 ft 9m 50 ft 15m 79 ft 24m 201 ft 61m 100 28 ft 8m 45 ft 13m 71 ft 21m 181 ft 55m 110 25 ft 7m 41 ft 12m 65 ft 19m 164 ft 49m 120 23 ft 7m 37 ft 11m 59ft 17m 150 ft 45 130 21 ft 6m 34 ft 10m 55ft 16m 139 ft 42m 140 20ft 6m 32 ft 9m 51 ft 15m 129 ft 39m 150 18 ft 5m 30 ft 9m 47 ft 14m 120 ft 36m 160 17 ft 5m 28 ft 8m 44 ft 13m 113 ft 34m 170 16 ft 4m 26 ft 7m 42 ft 12m 106 ft 32m 180 15 ft 4m 25 ft 7m 39 ft 11m 100 ft 30m 190 14ft 4m 23ft 7 m 37 ft 11m 95 ft 28m 200 14ft 4m 22 ft 6m 35ft 10m 90 ft 27m 30 XSD27ZIR e wision APPENDIX III RS485 BUS BASIC K
28. m Tem 027C 080F Booting Up Protocol Dome control protocol 14 Baud Rate Dome control baud rate Camera ID The dome ID address set by dip switch or keyboard See APPENDX I Camera S N Camera serial number Model Speed dome model number Version Hardware and software version Protocol Ernitec Baud Rate 4800BPS Camera ID 001 Camera S N 8888888888 Mode Version 8 01 Outer Temp 022C 071F System Tem 027C 080F Bootup Success MB ACCESSING MAIN MENU Display the dome s main menu on your monitor by calling preset 95 or calling preset 1 twice within 5 seconds Note For third party keyboard controllers please read user manuals as command to a preset may not be the same among different manufacturers In case password protection is in effect input the correct 6 bit password to enter the OSD menu Default password is 123456 Toenter password move the joystick up or down to select number 0 9 move the joystick left or right to choose password the digits If the input password is wrong the password input window will disappear The OSD menu will close automatically after 1 minute without any operation All the settings will be saved automatically to protect against power outage XSD27ZIR vision MENU OPERATION 2 Move the joystick down to point the cursor to MI SELECTING A MENU ITEM
29. nd the glass with water drop or dust Target moves too fast Large area target such as wall Target is too dark or vague Joystick AF Al gt is set None or Joystick AF Al is set Iris and Auto Focus is set to off 18 XSD27ZIR vision CAMERA PARAMETERS MENU il CAMERA MENU OPTIONS Main Menu gt Camera White Balance Auto BLC Mode Back H WHITE BALANCE Main Menu gt Camera gt White Balance White balance is normally compensated for by the automatic white balance gain control In some lighting conditions user may want to manually adjust the red and blue settings for optimal viewing The setting options are Auto Auto White Balance default setting Manual Manually set the red and blue values Move the joystick right to enter the manual setting The following window will appear WB R 000 WB B 000 Back R Gain 000 255 Adjusts RED color depth B Gain 000 255 Adjust BLUE color depth 19 ii BLC MODE Main Menu gt Camera gt BLC Mode R Gain 000 255 Adjusts RED color depth B Gain 000 255 Adjusts BLUE color depth If the backlight is bright the objects in the center of the picture may appear dark The dome can auto adjust the brightness of the whole image according to the brightness of center point Thus backlight compensation can increase the brightness of the objects in the center of the picture
30. nt or cables 2 Install outdoor cable laying out under eaves as possible as you can 3 In open areas shield cables in a steel tube and conduct a single point ground to the tube Using trolley wire is forbidden in such circumstances 4 In areas with high risk of strong thunderstorm or in high faradic areas such as high voltage transformer substation extra strong lightning proof equipment must be installed 5 the building s lightning proof requirements into account when surveying the lightning proof levels and the grounding of outdoor equipment and cable Install in accordance with the national and industrial standards 6 system must be grounded with equal potentials The earth ground connection must satisfy the anti interference and electrical safety requirements and must not short circuit with high voltage electricity When the system is grounded separately the resistance of down conductor should be 4 Ohms Video cable lightning conductor Com n unication cable lightning conductor Lightning md Powercabk lg htng conduc tor 15 i E The dom em ust be N hstaledw ithin the en M5 anglearea oder the lighta ng ma ith the vertical 1 Inetas the bise tor Ihe msistance of N Jown conductor shouk be S49 N D Sh H Stee Lube 33 XSD27ZIR vision APPENDIX VI WARRANTY TECHNICAL SUPPORT For Technical Support for any Xvision product please contact your l
31. ocal distributor LIMITED WARRANTY This product is supplied with a 1 Year warranty The Warranty excludes products that have been misused including accidental damage and damage caused by normal wear and tear In the unlikely event that you encounter a problem with this product it should be returned to the place of purchase 34 XSD27ZIR amp wisiori 35 XSD27ZIR Manufactured exclusively for Xvision www x vision co uk vision MIN UK Europe Xvision Group UK Unit 2 Valley Point Beddington Farm Road Croydon Surrey CRO 4WP Email sales x vision co uk Far East Kyoung Am Building 157 27 Samsung dong Kangnam ku 135 090 Seoul Korea Email globalsales x vision co uk 36 Middle East Burjuman Tower 18th Floor PO Box 121828 Dubai 43659 United Arab Emirates Email mesales x vision co uk North America 100 Park Avenue New York City New York 10017 United States Email usasales x vision co uk
32. p or down to select desired number Title To set the current preset title Move the joystick right to enter Title then move joystick right to desired bit and move the joystick up or down to select the letters you require NOTE You can input a maximum of 16 letters If you are not familiar with the editing please refer to Operating Instructions Setting Select this item to set the preset position and zoom The following menu will pop up when Set Current is selected Call Preset 1 To Confirm Move the camera to the desired position and zoom to a suitable level call preset 1 to save the current preset Remove Current gt Select this to delete the preset with the number and title displayed above Back Select to go back to the upper menu i TOUR Main Menu Auto Running Tour Tour Number 001 Dwell 001 Edit Test Run Back A tour is a sequence of presets When running a tour the camera moves from preset to preset and will dwell for a specific time for each preset It is useful if you need to repeat switching among a number of presets E g A shopping mall has several entrances A tour can automatically loop the position of each entrance NOTE 4 tours can be set in the system Each tour can contain up to 27 presets The dwell time for each preset is independent Tour Number Displays the current tour num
33. s on a keyboard controller It can also be controlled through the OSD menu The OSD menu can be activated by preset 495 call or double calling preset 1 call twice within 5 seconds Preset calling can be done through a keyboard controller or any other device e g a computer that can send commands to the speed dome OSD menu operations are specified as follow MB PREHEATING SCREEN When power on the dome and system temperature is under 15C 5F following screen shows up Outer Temp 030C 022F System Temp 020C 004F Fan Speed 6480rpm System Under 15C 5F System Heating Up Please Wait The system will heat up until the system temperature is above 15C 5F System starts to boot up after heating up finishes lt Outer Temp gt Environment temperature XXC XXF C Celsius F Fahrenheit System Tem gt System inner temperature lt Fan Speed gt The rotating speed of the fan M BOOT UP SCREEN When power on or restart the dome the boot up information will display on screen and then the dome will begin self testing System booting up will show on the screen until boot up success shows up The whole boot up process lasts about 40 seconds This screen display disappears once the dome receives any effective command Protocol Ernitec Baud Rate 4800BPS Camera ID 001 Camera S N 8888888888 Mode Version 8 01 Outer Temp 022C 071F Syste
34. t Site Info Display Setup Bootup Screen Password Set Default System Reboot Back SYSTEM INFO includes following settings Site Info Dome ID name broadcast address Display Setup Screen display Bootup Screen Display boot up information Password Change password Set Default gt Restore factory default settings Reboot System Reboot dome system BI SITE INFO Main Menu gt System gt Site Info Site ID 007 Name Is Bond Broadcast Add 255 Back Site ID Shows the current dome s ID Each dome has its unique ID ID ranges from 001 to 254 NOTE Site ID can be set by menu only when DIP switch is set to programmable ID Move the cursor to lt Site ID gt and then move the joystick right to enter dome ID setting sub menu as follow Site S N 8888899999 Input S N 0000000000 Back Move the cursor to lt Input S N gt then move the joystick right input the serial number according to the lt Site S N gt and then move the joystick left to exit setting Go to lt Back gt and move joystick right to exit Finally 16 move joystick up or down to select desired ID number Move the joystick left to save the settings lt Name gt Name refers to the title of the dome Assign a dome name to remember which dome it is lt Broadcast Add gt Used to set the broadcast ID number The ID f
35. the connection between flat control wire and socket on base is fixed M CORNER MOUNT Check carefully to make sure the wall is firm and does not peel off It is required that the wall can withstand 8 times weight of the dome set 1 Mark the fastener positions 2 Install base Use the corner mount base as the template to mark Feed the Power RS485 Video cables through the hole of the mounting positions on wall corner mount base and use M8 nuts to fasten corner base on the mounting surface NOTE Put cables through the wall of aside the corner base 3 Install bracket 4 Install housing Put cables through the cavity of bracket and fasten Feed the cables through the hole on top of the housing Align bracket on base the dome casing to the bracket and fix with 2 M5 screws as shown NOTE Apply water proof tape to the thread in the case of EN 13 outdoor dome XSD27ZIR e wision 5 Set dome ID baud rate and protocol Set dome ID bard rate and protocol by configuring DIP Switches see APPENDIX I NOTE Remove the packing sponges 6 Connect cables Plug cables into corresponding sockets on circuit board Reinstall the circuit board and turn on the power Turn off the power after checking NOTE Names of the interfaces are marked on the terminal block or PCB Connect cables as shown in the diagram Make sure power is off before connecting 7 Install black liner and Pan Tilt Mod
36. to Manual BLC On Off Privacy Mask No Focusing system Auto Manual Video Output BNC Output DECLARATION This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense PRECAUTIONS Only qualified and experienced person can carry out the installation In many countries and areas licensed personnel is required Always take safety codes into consideration during installation Use reliable tools only poor quality tools may cause damage to both human and property Check the strength of all item onsite that are related to installation in advance It is recommended that the stand of dome be 8 times stronger than the weight of the dome and its accessories Keep all the original dome package materials in case of future repacking and transportation Choose and install speed dome according to environment requirement Refer to the Product Features This product conforms to IP66 standard as specified in Housing Protection Classification IP code WARNINGS Avoid installing this speed dome in hazardous places where inflammable or explosive materials are stored or used Indoor dome is not designed
37. ule Please inseret flat wire into socket strongly and be sure to be locked Please be sure that the connection between flat control wire and socket on base is fixed C24V GND AC24V 485 485 VIDEO VIDEO too 8 Install down cover Unscrew the two M4 screw on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws NOTE Apply lube to the O ring for external mounting XSD27ZIR vision MPOLE MOUNT The Pole mount can be installed on pole with diameter of 130 to150mm 5 12 to 6 1 Install base 2 Install bracket Feed the Power RS485 Video cables through the central Put cables through the cavity of bracket and fasten it on base hole of the bracket base and then fix it to the pole L 3 Install housing 4 Set dome ID baud rate and protocol Conduct cables through the hole on top of the housing Set dome ID bard rate and protocol by configuring DIP switches Align the fast connector to bracket and fix with 2 M5 see APPENDIX Screws NOTE Remove the packing sponges NOTE Apply water proof tape to the thread for external mounting M5 Screw 5 Connect cables Plug cables into corresponding sockets on circuit board Reinstall gt EE dy 2 dai the circuit board and turn on the power Turn off the power after HE ee checking e ee 9 s AIE ou o e NOTE
38. unctions the same as dome s site ID default setting is 255 The dome responds to commands sent to either ID Refer to Changing Values to learn how to set the broadcast address Select BACK to return to upper menu II DISPLAY SETUP Main Menu System gt gt Display Setup Site Name On Preset Title On Cruise Title On Pattern Name On Orientation On Zone Name On Cross Curser On Off Back The on screen display can be customized using this menu lt Site Name gt Choose to display the site name lt Preset Title gt Choose to display cruise title when the dome is in cruise mode lt Cruise Title gt Choose to display preset title when calling preset lt Pattern Name gt Choose to display pattern title when the dome is replaying pattern sequences lt Orientation gt Choose to display the current lens pointing direction lt Zone Name gt Choose to display the current zone title Select BACK to return to upper menu XSD27ZIR vision M BOOT UP SCREEN Main Menu gt System gt gt Bootup Screen Camera S N 8888888888 Camera ID 001 Baud Rate 9600bps Model Version 8 01 Outer Temp 022C 071F System Tem 027C 080F Call Preset 1 To Back Bootup screen displays summary information of the dome Values are fixed in this sub menu Refer to Bootup Screen to check the item Call preset 1 to return to upper menu ill PASSWORD