1. Se SATEC Powerful Solutions Win a Tablet PM135 Quick Start Manual see back page This quick start manual is a short guide on how to mount connect configure and operate the PM135 It is not intended to replace reading the full user manual and particularly the safety precautions Mounting electrical connection and settings of the PM135 shall be made in A N accordance with all applicable laws and or regulations and be performed by authorized personnel only MOUNTING Position the PM135 meter in 92x92mm square or 4 round cutout Figure 1 If two PM135 are positioned side by side keep at least 150mm 5 9 between their centers to allow installation of add on modules 140mm 5 5 if only small form modules will be used Attach the PM135 unit using washers and nuts Make sure that the unit is securely attached into the wall or cabinet fixture FLAT WASHER WIDE 8 LOCK WASHER 8 PM NUT HEX 8 32 Ere Uo BGO517 REV A1 ENGLISH PM135 QuickStart www satec global com CONNECTION To connect follow these steps Figure 2 shows a 4W LV installation with conventional CTs Ensure that all incoming power sources are OFF Check that you have the appropriate power supply Connect the Power Supply inputs using 1 5 mm 14AWG dedicated wires and breaker Connect to the external CTs by passing the external CTs wires through the meter CT cores Observe the arrow that indicates the current direction Figure
2. 2A For HACS connect the red or white wire to the and orange or black wire to the terminal 5 In case of a retrofit application where each external CT ends with two wires Note 2B 5 1 Pass one wire through the meter CT core 5 2 Connect the wire to one of the meter optional CT wire termination screws 5 3 Connect the second wire from the external CT to the termination screw 6 Connect the measured voltage inputs Connect COM1 RS 485 communication port 8 To connect the optional module 8 1 Make sure that the power is turned off 8 2 Remove the module cover 8 3 Attach the module and fasten the screws 8 4 Connect the module I O or communication see Figure 2C for DI O wiring 9 Turn the power up 10 Make sure the diagnostic led is off and solid 123 phase indication is displayed BWN PR N Line 2 B Ie l Line 3 C O NG thie ae ey HTL Line 1 A Kann ine1 AVO Tho Figure 2 tS yet a SLAVE RS 485 UP TO 31 POWERMETERS CT MARKINGS The optional CT wire termination allows connection of the two wires from the CTs They have no internal connection and their use is optional PM135 QuickStart www satec global com OPERATION The PM135 is operated using the front panel which consists of an LCD display 12 LEDs and five keys as shown below PM135EH Diagnostic LED Off OK real time min max 10 1 n 100 AALI hai
3. Digital O Diagnostic Alarms Basic Settings Page1 Page2 Device Info Info Com PM135 QuickStart www satec global com CONFIGURATION The essential configuration includes 1 Basic measurement setup 2 Communication setup and testing 3 Resetting the min max energy demands etc Additional recommended configuration set points TOU and data logging Note It may be easier to configure communication first and use PAS software for setup Basic Measurement Setup In any display screen press MENU A V W 1to enter the Basic Settings Display Parameter Description Default Wiring Mode see below Network wiring configuration 4LN3 PT Ratio Transformation ratio of the Potential Transformers 1 PT Ratio Multiplier Additional PT factor for EHV network X1 CT Primary Current The Primary Rating Of The Current Transformers 5A Power Demand Period Duration in minutes of the power demand period 15 E amp EH models calculations E External pulse in DI1 Blocks in Sliding Demand The number of blocks to be averaged for sliding window 1 E amp EH models demands Volt Ampere Demand Period Duration in seconds for voltage and current demand 900 Nominal Frequency The nominal frequency 60 Hz Max Demand Load Current 0 CT primary current Other max current 0 Wiring Mode Setup 3 wire 2 element Delta direct connection using 2 CTs 3DIR2 4 wire 3 element Wye direct connection or 3PTs and 3 CTs 4LN3 or 4LL3 3 wire 2 element Open De
4. Temani Title displayed value units Load bar graph emi a full load according to un pies CT or in Display Setup SE Main display Em 0 So gt O Status line see below Communication Indication Select Enter TAB Change screen Calibration LED 1 pulse Wh or Varh Menu Escape Scroll up down Status Line Date time operation mode current tariff T1 T8 phase indicators and power flow direction Operation modes NORM and TEST In the TEST mode the energy registers are not accumulated and the calibration led is 10 times faster 10 pulses per Wh or varh Phase indication is on when voltage is ok blinking when below voltage dip set value or marked as when below the interruption set value Power flow direction Normal flow generation to load H reverse flow Ht or no load K Display Screens Group gt to change Screens A to go right V to go left Underlined included in Auto Scroll Voltages VL L VL N THD Ue Hz Phase Demand Currents Amps THD TDD K Factor Unbalance Demand Powers Total L1 L2 L3 Import Demand Export Demand Demands P Import P Export Amps Volts Min Max VL L VL N Amps neutral P PF Hz Energy Import Export TOU Import Export Reg 1 Reg 2 Harmonics 3 5 7 39 Spectrum V1 V2 V3 11 2 13 Waveform L1 L2 13 Phasor
5. lta connection using 2 PTs 2 CTs 30P2 4 wire 2 4 element Wye connection using 2 PTs 3 CTs 3LN3 or 3LL3 3 wire 2 element Open Delta connection using 2 PTs 3 CTs 30P3 4 wire 3 element Delta direct connection using 3 CTs 4LN3 or 4LL3 3 wire 2 element Broken Delta connection using 2 PTs 3 CTs 3bLN3 or 3bLL3 LN or LL denotes the default use of L L or L N voltages in thresholds min max demands etc Communication setup and testing In any display screen press MENU A 4 5 times A and to setup the built in RS 485 port COM1 If communication module is present configure also COM2 Resetting the min max energy demands etc Press MENU A 4 4 to enter the reset menu Select the value to be reset press 4 to select then press 4 for 5 seconds until the Do notification is changed to Done For a Chance to Win a Tablet Register Your Product Here www satec global com register Copyright 2013 SATEC Ltd PM135 QuickStart www satec global com

Download Pdf Manuals

image

Related Search

Related Contents

gebruiksaanwijzing instructions for use mode d`emploi  V660 Rundballenpresse Betriebsanleitung Version 5  Samsung MM-D430 Manuel de l'utilisateur  Dolphin&AquaRanger UM- SDP05812(Fre) copy  SV1107IPEXT - StarTech.com  VDP_mars09  HP ProLiant BL660c Gen8 Server Blade  Pioneer Kuro PRO-101FD User's Manual  