1. CTC UNION TECHNOLOGIES CO LTD V3 47 16 FRM 301 Fiber Optical Media Converter Ra Management kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkxk kkkkkkkkxk Main Menu and Rack Status Slot 1 gt gt Empty lt lt Slot 2 gt gt Empty lt lt Slot 3 gt gt Empty lt lt Slot 4 gt gt Empty lt lt Slot 5 gt gt Empty lt lt Slot 6 gt gt Empty lt lt Slot 7 gt gt Empty lt lt Slot 8 gt gt Empty lt lt Command Function Key 1 to 9 A to G I O Cards Setting P Show Fans and Powers Status R Refresh Status ESC Logout M Manager Configuration Setup S System Configuration and TFTP Setup Console On line Telnet Off line GUI Off line Slot 9 El BNC Slot 10 10 100 Slot 11 10 100 Slot 12 10 100 Slot 13 10 100 Slot 14 10 100 Slot 15 10 100 Slot 16 10 100 Q i Hi O A amp W gt L Note that the version is now 3 47 The 16 denotes that the Control Card s CPU firmware version is 2 16 This completes the SNMP upgrade procedure Fiber Series Units CTC Union Technologies Co Ltd Far Eastern Vienna Technologies Center Neihu Technology Park 8F No 60 Zhouzi St Neihu Taipei Taiwan Phone 886 2 2659 1021 Fax 886 2 2 799 1355 E mail info ctcu com http www ctcu com
2. Command Function Key 1 to 5 Configure Setting R Reset All Setting to Default S Store Setting and Reboot T TFTP and Flash ESC Main Menu Press T to start the TFTP upgrade Press Y to confirm Sure to TFTP and Reset Y N TFTP NOW LOADING Loading ok Please don t power off Flashing now 0000000000000000000000000000000 Flash completed System reset Please wait Attached TCP IP interface to secEnd unit 0 Attaching interface lo0 done To confirm that a TFTP transfer actually took place you may view the TFTP application on the PC before closing it inix About Name TFTP Manager IP Address 172 24 1 126 en 1 Opened 5 35 42 PM Action Session 0 Total Index Action P_ Type Tftp File Name Status 1 172 24 1 4 Get c frm3v3471 bin OK 5 41 32 PM Start transferring ot PM Transfer OK Note that one transfer did occur SNMP Upgrade Procedure FRM301 Watch the SNMP LED on the SNMP card of the FRM301 When the LED returns to a constant 1 blink per second the SNMP agent has rebooted If this is an online upgrade each line card will experience a brief 2 seconds loss in transmission while the card is polled by the SNMP at boot time You may now Close the TFTP server OK now let s verify the version number of the SNMP To do that just login to the terminal of the FRM301 KAKKKKKKKKKKKKKTKKTKKTK TE KK KK KK TE IT ET TI KT KT TI TE TAT N AU KU I
3. User Manual FRM301 SNMP Upgrade Procedure CIC CTC Union Technologies Co Ltd ISO 1 FRM301 SNMP Upgrade Procedure Version 1 0 July 2005 CTC Union Technologies Co Ltd 2005 All rights reserved The contents of this document are subject to change without notice SNMP Upgrade Procedure FRM301 1 0 Introduction The purpose of this document is to outline the procedures and pitfalls in upgrading the SNMP of the FRM301 1 1 Preconditions The FRM301 must be using hardware version 2 0 SNMP card The Control Card in the rack must be using version 2 16 CPU firmware version as of this writing If an SNMP option is being installed for the first time you will also be installing a Control Card Now would be the best time to be sure the Control Card has the latest firmware The Control Card s CPU firmware upgrade is support by chip replacement only The original version 2 0 hardware SNMP was released with SNMP code version 3 42 for the FRM301 The SNMP is upgraded by using TFTP Trivial File Transfer Protocol The SNMP agent provides the ability to upload the new code re flash the flash memory and reboot with the new SNMP operational code 1 2 Items required a The FRM301 unit with SNMP option installed and network connection Version 3 4X to be upgraded to version 3 47 as of July 2005 b A Windows based PC with a network connection and with at least one free Com port telnet and terminal emulation software such as HyperTer
4. a default gateway of 172 24 190 254 Our PC is set with an IP address of 172 24 1 126 and our FRM301 has an IP address of 172 24 1 4 SNMP Upgrade Procedure FRM301 3 0 Setup the FRM301 The following screens will show the detailed procedures to setup the networking for the FRM401 and prepare for TFTP upgrade of the SNMP Once the console port is connected to a terminal the following screen will display kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkxk kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk CTC UNION TECHNOLOGIES CO LTD v3 45 16 FRM 301 Fiber Optical Media Converter Rack Management kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkxk Main Menu and Rack Status Slot 1 gt gt Empty lt lt Slot 2 gt gt Empty lt lt Slot 3 gt gt Empty lt lt Slot 4 gt gt Empty lt lt Slot 5 gt gt Empty lt lt Slot 6 gt gt Empty lt lt Slot 7 gt gt Empty lt lt Slot 8 gt gt Empty lt lt Command Function Key l to 9 A to G I O Cards Setting P Show Fans and Powers Status R Refresh Status ESC Logout M Manager Configuration Setup S System Configuration and TFTP Setup Console On line Telnet Off line GUI Off line Slot 9 El BNC Slot 10 10 100 Slot 11 10 100 Slot 12 10 100 Slot 13 10 100 Slot 14 10 100 Slot 15 10 100 Slot 16 10 100 Q Ai Hi O A amp W gt L If you are pr
5. esented with login prompt please enter the unit s password If you forgot it the super user password for terminal mode is 1021 no quotes The actions we must first take are to configure the TCP IP settings of the FRM301 if they are not already set Next we will setup the information required to access the TFTP server Lastly once the TFTP server is running on our network we will execute the TFTP upgrade SNMP Upgrade Procedure FRM301 Select item S System Configuration and TFTP Setup La 2 2 2 2 2 2 22 22 2 2 2 22 22 2 2 22 2 2 2 2 2 22 22 22 2202 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 22 202 220 20203 x CTC UNION TECHNOLOGIES CO LTD V3 45 EX FRM 301 Fiber Optical Media Converter Rack Management kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkxk System Configuration and TFTP Setup Menu MAC Address 0002AB091234 IP Address 172 24 1 4 Subnet Mask 255 255 0 0 Gateway IP 172 24 190 254 TFTP Server IP 172 24 1 126 TFTP Server Path c f rm3v345 bin Command Function Key 1 to 5 Configure Setting R Reset All Setting to Default S Store Setting and Reboot T TFTP and Flash ESC Main Menu If the TCP IP settings are not already correct use menu items 1 3 to set the FRM401 for your network For menu items 4 and 5 set the IP address for the TFTP server or the PC running the TFTP Server daemon Enter the path and filename where the image file is placed on the TFTP ser
6. minal c Serial console cable DB9M to DB9F d Ethernet UTP cables e SNMP ver 3 47 binary image file f CTC Union TFTP server for Windows or other TFTP server 2 0 Equipment Setup The upgrade procedure could possibly have effect on the traffic passing through an online FRM301 unit It is recommended that the unit be taken offline for maintenance Obviously changing of Control Card firmware requires removing the card with power off The procedure for removing the Control Card is all outlined in the User s Manual and will not be repeated here If you are going to upgrade a unit s SNMP while the rack is online and transmitting traffic choose a time of day when the few seconds of traffic interruption will have minimal effect such as the middle of the night Two connections are required between the PC that will do the upgrade and the FRM301 that will be upgraded First a console connection with terminal emulation program such as HyperTerminal with settings of 38 4K baud 8 bits no parity 1 stop bit and no flow control The second connection is an Ethernet connection either through a network or with a direct connection and crossover UTP cable Check the Ethernet settings of the FRM301 through the console mode Either change the settings to match the network settings of your PC or set the PC s settings to match the FRM301 s network settings In the following example we are on a 172 24 0 0 network with a subnet mask of 255 255 0 0 and
7. ver For example to set the TFTP server s IP address press 4 TFTP Server IP gt 172 24 1 126 TFTP Server Path gt c frm3v3471 bin Enter the IP address of the PC running the TFTP service in our case 172 24 1 126 and the path to the upgrade file If you have made any changes to items 1 5 you must store and reboot the SNMP Press S to store the results and reboot the SNMP agent If this is an online upgrade each line card will experience a brief 2 seconds loss in transmission while the card is polled by the SNMP at boot time Start the TFTP server on the connected PC In our example we are using the CTC Union TFTP server inix About Name TFTP Manager IP Address 172 24 1 126 0 Opened 15 35 42 PM Action Session 0 Total Index ActionIP _ Type Titp File Name Status SNMP Upgrade Procedure FRM301 When the agent comes back up on our terminal enter the password if required and again go to the System Configuration and TFTP Setup menu kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkxk CTC UNION TECHNOLOGIES CO LTD V3 45 ER FRM 301 Fiber Optical Media Converter Rack Management kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk System Configuration and TFTP Setup Menu MAC Address 0002AB091234 IP Address 172 24 1 4 Subnet Mask 255 255 0 0 Gateway IP 172 24 190 254 TFTP Server IP 172 24 1 126 TFTP Server Path c rm3v3471 bin
Download Pdf Manuals
Related Search
Related Contents
NEC NP-V311X Installation and Setup Guide USER MANUAL - Hatteland Display AS US Stove MH6 Installation Guide SmartCom3 Installation and Operating Manual v2 XS Technical Reference – Hardware digital thermometer digitális termométer SAFETECH 2016 - Safe and Vault Technicians Association Lucasey FSCT flat panel ceiling mount Manual - Infusion Systems Copyright © All rights reserved.