1. 2 System requirements Windows XP 7 or 8 32 or 64 bit IMB Ram Compatible with touch screen devices 3 Software Installation 1 Run the install bat file This creates a folder named Delta Dome The Delta Dome Overtravel Monitor application file DD exe will be located here Create a shortcut to the DD exe file on the desktop for ease of use Run the icalsetup exe file and follow on screen instructions to install InstaCal Note if installing on a computer that already has InstaCal such as a computer that already has the Free Stroke Analyser software installed this won t be necessary Connect the interface box to the computer using the USB cable supplied Wait until the hardware is detected and installed by Windows should take less than a minute Run InstaCal select Start gt All Programs gt Measurement Computing gt InstaCal If another device has previously been used such as the Free DELTA H TECHNOLOGY 4 Stroke Analyser a message will appear that the device has not been detected Click OK to delete that device The Delta Dome interface box should be automatically detected and be listed as Board 0 USB 1608FS InstaCal can then be closed If there are any communication problems between the computer and the interface board InstaCal can be run again as described above 5 If the Delta Dome Overtavel Monitor is to be used on the same computer as the Free Stroke Analyser bodymaker alignme
2. of the dome station housing On screen instructions are provided of how to reset the sensitivity This involves moving the dome station housing or the sensor a known distance DELTA H TECHNOLOGY 12 Enable Automatic Bodymaker Protection is only available for units supplied as a permanent installation on the bodymaker where outputs are linked to the bodymaker PLC to provide protection see Section 10 10 0pen Save Measurements can be saved onto the hard drive for future reference When saving all the measurements that are currently displayed in the graphs at the time of saving will be saved The signature of the last stroke will also be saved Saved measurements can be viewed on screen and also printed out in an A4 format The measurements are saved into a database on the hard drive The database is a series of folders in the C Delta Dome Data Files folder There are folders for plants lines and bodymakers The measurements are saved into the bodymaker folders The database can be setup using the Database Setup button from the Open Save window 11 Outputs If enabled in the Setup outputs from the device in the interface box provide signals for the bodymaker control software to for example stop the bodymaker when the overtravel is too high or too low DELTA H TECHNOLOGY zi The outputs switch between 0 and 24V There are 2 outputs The first will normally be at 24V switching down to OV when there is an overtravel alarm Th
3. Delta Dome Overtravel Monitor Version 2 03 June 2015 User s Manual Revision date 18 June 2015 DELTA H TECHNOLOGY LTD Contents 1 About the Delta Dome Overtravel Monitor 3 2 System requirements rennais tie 4 3 Software Installation 4 4 Fitting th CMSA unes 5 5 Connection Instructions 7 6 Sensor AdIUSIMRNL username 7 Te Man Display en ee 8 Ss SIS HUUTRS dde rm de 10 o OUR a 11 10 CODE SAVE Re ne 13 11 CAD nes med 13 12 SUP 010 a Las nes ne ira ane nat e st 14 DELTA H TECHNOLOGY EPT 1 About the Delta Dome Overtravel Monitor The Delta Dome Overtravel Monitor provides safe and accurate measurement of dome bottom former overtravel It is easy to fit to the bodymaker and measures every stroke at any bodymaker speed during normal continuous running There are two hardware variants available The first is a portable device for use as a setup tool One unit can be used for measuring dome overtravel on any bodymaker in the plant The other variant is a permanent installation on every bodymaker in the line The electrical hardware including a touch screen computer can be installed in existing control cabinets or in a dedicated enclosure close to each bodymaker Outputs from the device are linked to the bodymaker PLC to stop the bodymaker if the overtravel goes out of spec The software is the same for both variants DELTA H TECHNOLOGY 3
4. e second is set to OV when the sensor is out of range or the system is not actively monitoring the overtravel for example when Setup Open Save or Signature are selected The bodymaker PLC can be programmed to stop the bodymaker if either output is OV It should check on every stroke except the first 2 or 3 strokes This is to allow any alarms to be reset after the first stroke overtravel is measured Different messages can be displayed on the bodymaker fault display depending on which output is OV For example they could be programmed to say Dome Overtravel Fault and Overtravel Monitor Inactive 12 Support Web www deltahtechnology co uk Software updates can be downloaded from the website email davidharvey onetel com DELTA H TECHNOLOGY 14
5. e fitted whenever the connector is disconnected This prevents coolant contamination The interface box connects to the computer or tablet using the USB cable provided 6 Sensor Adjustment The main screen of the Delta Dome Overtravel Monitor software shows the sensor output in volts the dark blue DELTA H TECHNOLOGY LE bar This will be 10V when the gap between the sensor face and the dome station housing is more than about 5mm and drops as the gap is reduced With the bodymaker not running the sensor position should be adjusted to give an output of between 1 and 3 volts the top of the blue bar will then be within the green band The red Sensor Posn alarm in the top right corner of the screen will be shown if the sensor is not positioned correctly The sensor and bracket should then be locked in position by tightening the screws and locking nuts The gauge is then ready to begin making overtravel measurements 7 Main Display Overtravel measurements are shown in the top trend graph and the last measured overtravel is given numerically in the top left corner of the display The bottom trend graph shows the bodymaker speed in cycles per minute This is useful because dome overtravel is dependent on bodymaker speed The speed in calculated from the time between successive overtravel measurements The speed for single strokes will therefore not be measured or displayed on the graph DELTA H TECHNOLOGY 8 The g
6. e given in crank angle degrees Otherwise it will be shown in milliseconds A typical signature is shown in the picture Overtravel Profile of Last Stroke Zoom In Zoom Out INFO The Delta Dome software checks the signature and automatically disregards the measurement if it is not consistent with what should be obtained from dome overtravel This can happen if there is noise on the signal or if there is vibration possibly caused by the impact of the redraw hold down or the overtravel itself If the overtravel is very low around 0 002 or 0 05mm or less it is difficult to distinguish between real overtravel and DELTA H TECHNOLOGY 10 noise or vibration so it is worth checking the signature to make sure the measurement looks like a real overtravel measurement The signature should show the overtravel as a sharp spike at zero on the crank angle or time axis approximately 2 to 15 or 1 to 10 ms wide depending on the size of the overtravel and the speed if the x axis is in ms Any other movement shown on the signature may be caused by the outer domer vibration or electrical noise on the signal If the signature shows movement that is not typical this may indicate that there is a fault with the dome station 9 Setup Graph Range Units Overtravel Range C inches BM Speed Max amp thou 0 001 inch BM Speed Min Emm Max number of strokes Sensor Sensitivity Alarms About Delta Dome S
7. nt software which has a USB interface box similar to the Delta Dome interface box the following instructions will ensure that both will work With the Delta Dome interface box still connected connect the Free Stroke Analyser interface box using another USB port Run InstaCal and both interface boxes should be listed the Free Stroke Analyser one being Board 1 InstCal can then be closed In the Free stroke Analyser software under Options change the board number to number 1 4 Fitting the Sensor Using the bracket provided fit the sensor so that there is approximately a 2mm gap between the sensing face and the dome station housing The bracket provided will be suitable for either a CMB Microdomer or a Pride dome station DELTA H TECHNOLOGY 5 Fitted to CMB Microdomer Fitted to Pride Domer The exact position of the sensor needs to be set using the Delta Dome Overtravel Monitor software to check the output from the sensor The sensor cable needs to be fed out of the bodymaker guarding This should be done in such away that the cable will not get caught on any moving parts and also not damaged by trapping it between the guards DELTA H TECHNOLOGY 6 5 Connection Instructions The sensor cable is fitted with a water tight connector which connects to the cable of the interface box It is a push pull connector with a spring loaded locking sleeve The connectors also come supplied with protective caps which should b
8. pec Top Limit Spec Low Limit Double Dome Sensitivity Enable Automatic Bodymaker Protection DELTA H TECHNOLOGY ali Max number of strokes can be changed to enable the overtravel from more or less strokes to be seen in the graph It can be set to anything between 50 and 100000 The software records up to 100000 overtravel measurements in its memory and this is not affected by the value of Max number of strokes Therefore it can be changed to a high value to review the overtravel over a large period of time 100000 strokes is approximately a few hours of running or to a lower value to analyse any changes in overtravel over a shorter time period Note the trend graph is initially sized to show 50 strokes irrespective of the value of Max number of strokes and this automatically increases as more strokes are measured until it reaches the value of Max number of strokes Double Dome Sensitivity is the amount the overtravel has to increase between consecutive strokes for the Double Dome Alarm to be activated A double dome refers to the situation where the base of the can is not stripped off the punch or remains stuck in the dome die Sensor Sensitivity has a default setting of 2 6 V mm and this should give reasonable accuracy However it should be checked and reset when the gauge is initially used It will not require further resetting unless a different kind of sensor is used or there is a change in the material
9. reen band in the overtravel graph represents values between the top and bottom specification limits set in Setup If an overtravel measurement falls outside of these limits an alarm will be given at the top of the display The possible overtravel alarms are Over Spec Under Spec or Double Dome Once activated these alarms stay on for 20 strokes or until the bodymaker restarts after a stop The Double Dome alarm is given if the change in overtravel from the previous stroke is more than the value of Double Dome Sensitivity given in Setup There is also a No Overtravel alarm which is given when no overtravel is detected This alarm therefore always comes on when the bodymaker is not running but also when it is running but there is no overtravel The Sensor Posn alarm is explained in the Sensor Adjustment section If this alarm is shown the gauge may not measure correctly and the sensor position should be re adjusted If a measurement is incorrectly made this may happen when adjusting the sensor or if you just want to clear the data from the graph to start from fresh measurements can be deleted by selecting the Delete button DELTA H TECHNOLOGY 9 8 Signature The signature of the last measured overtravel can be viewed by selecting Signature This shows the overtravel movement for the last stroke before and after the point at which maximum overtravel was obtained Where it was possible to measure bodymaker speed the x axis will b
Download Pdf Manuals
Related Search
Related Contents
Réaliser un index des noms propres avec Word sous Mac 取扱説明書 [F-10A] Il ou elle a dit Descarga - Energy Sistem Mode d`emploi «Réservation de tournoi en ligne 取扱説明書 - SOOKI Samsung GT-S3650 Užívateľská príručka Manual de Instruções Help file for ex_RLC example SERVICE MANUAL iRC2380/2880/ 3080/3380/3580/i Copyright © All rights reserved.