1.     WARNING   It is considered a safe practice  especially when using EAN  to open  A ithe cylinder valve slowly and let the first stage pressurize slowly  Rapid pressur     zation Causes adiabatic compression of the breathing gas  which generates heat   inside the first stage  Heat  along with elevated percentages of oxygen and an   ignition source  from contamination  are the ingredients that can cause com    bustion  This is why it is necessary to keep the interior of the regulator clean   and the fraction of oxygen below 40  along with the slow opening of the valve             ats Aqua LUNG    12 Back to the contents FIRST ho  DIVE    3 1 Mounting the First Stage Onto the Cylinder Valve  3 1 1 Yoke Connector       Partially unscrew the yoke screw of the first stage regu   lator so that the dust cap can be removed from the fil   ter and air inlet        With the cylinder valve facing away from you  release a small amount of air from  the cylinder by turning the handwheel counter clockwise to open the valve only  slightly  When air is heard exiting  immediately close the valve  This will clear any  moisture or debris that may be inside the cylinder valve outlet opening     Check the condition of the cylinder valve O ring    Place the first stage regulator over the cylinder valve so  that the inlet fitting aligns with the O ring of the cylinder  valve  and the LP hose of the primary second stage will  be routed over the right shoulder  While holding the  first stage in place
2.   The repair   modification  or replacement of parts during the guarantee period will not have  the effect of extending the guarantee period     e Our liability as a result of the sale is expressly limited to the above guarantee   and excludes all other penalties  damages and interests     e In order to benefit from the terms of the current guarantee when making a  guarantee claim  you must send the attached coupon  duly completed and  stamped by the retailer  together with a proof of purchase  cash register  receipt noting the date and the equipment purchased              Aqua LUNG    24 Back to the contents FIRST ho  DIVE       GUARANTEE COUPON     TO BE COMPLETED ON DAY OF PURCHASE   serial N   of first stage     serial N   of second stage     Regulator model      Purchase date      RETAILER STAMP    Name of the purchaser      Adress         25 Back to the contents    AQUALUNG    FIRST    TO    DIVE       10  Returning Your Regulator For Service    Whenever your regulator requires annual service or warranty repair  Aqua    Lung requires that you bring it or send it to your nearest Authorized Aqua Lung  Dealer     If you need to return products covered by this warranty  please provide your    dealer with photocopies of your original sales receipt and receipt from your last  annual service if the product is more than one year old     NOTE  Aqua Lung America  Inc  reserves the right to substantiate     the validity of the claim     11  Contacting Aqua Lung AMERICA via Electro
3.   turn the yoke screw clockwise  Ensure that the yoke screw  mates into the small dimple on the backside of the cylinder valve  and tighten  finger tight only        U Connector or Pr EN 144 3 connectc    Remove the protector cap from the cylinder valve     With the cylinder valve facing away from you  release a  small amount of air from the cylinder by turning the  handwheel counter clockwise to open the valve slightly   When air is heard exiting  immediately close the valve  This will clear any mois   ture or debris that may be inside the threaded cylinder valve opening        Check the condition of the cylinder valve O ring     Position the first stage near the cylinder valve so that  the LP hose of the primary second stage will be routed  over the right shoulder  Thread the first stage DIN  connector into the cylinder valve and turn the handw   heel clockwise by hand until it is lightly snug  DO NOT  use tools to tighten        Aqua LUNG    Back to the contents FIRST TO DIVE       l      14    3 2 Pre Dive Checks       1  Carefully inspect all hoses at their fittings to ensure they are securely  connected into their respective ports on the first stage  Inspect the length of  each hose to ensure that the hoses are not blistered  cut  or otherwise dama   ged  If hose protectors are present  slide the protectors back to expose the  hose fittings  and inspect the hoses as described above     2  Visually inspect both the first and second stage regulators for any signs of  exte
4.  SLOWLY     e NEVER lubricate any part of the regulator  particularly the O ring providing the  seal between the cylinder valve and the regulator  with any lubricant     e DO NOT apply any type of aerosol spray on the regulator  Doing so may cause  permanent damage to certain plastic components        e The user should not undertake any assembly  disassembly or adjustment    other than those prescribed     e Factory prescribed service for this regulator must be performed at least once  annually by a factory trained Aqua Lung Service Technician who is employed by  an Authorized Aqua Lung Dealer     e DO NOT use the regulator first stage as a carrying handle when lifting or  transporting the cylinder as this can damage the regulator or the cylinder  valve     e When diving in cold water  below 50  F  or 10  C   you must have received trai   ning and certification in the techniques of cold water diving from a recognized  training agency     e  f you are using a first stage in the Legend series  you are recommended to  use a compensated Octopus  LX Octopus  Legend Octopus  Kronos Octopus   Mikron Octopus  to avoid the possibility of a free flow at depth               as Aqua LUNG    4 Back to the contents FIRST ho  DIVE       1 2 ENRICHED AIR NITROX USE    DANGER   This chapter contains important information concerning use with oxy   gen enriched air  Nitrox  EAN   Do not attempt to use this product with enriched  air without having entirely read and understood this chapter  If y
5.  carries the  gt 10  C mark  this indicates that the regulator is not    intended for use in water at a temperature below 10  C    This mark can be found on the 1st stage body for Titan series regulators or on  the 2nd stage for regulators in the Titan LX or Legend series  See the photo          co gh C l         AQUALUNG    8 Back to the contents FURST TO DIVE          2 2 Features          Calypso Titan   Mikron Kronos   Legend  First stage Piston regulator Diaphragm regulator Diaphragm regulator  technolgy  Maximum working Yoke   232 bar Yoke   232 bar Yoke   232 bar  pressure USA   3300 PSI USA   3300 PSI USA   3300 PSI    DIN   200 bar DIN   300 bar DIN   300 bar    Number of ports 1 HP 7 16  4 MP 3 8   1HP 7 16  4 MP 3 8 2 HP 7 16   4 MP 3 8    Hose length 730 MM 730 MM 730 MM       2 3 VANE ADJUSTMENT SWITCH  VAS     The VAS can be found in one of two different locations depending upon which  model you have  lt can be located on the side opposite the hose connection OR  it can be found on top in front of the mouthpiece  It helps to maintain a high  flow of air once you have started to take a breath    When the VAS is set to the    MAX     or        position  the regulator will provide  maximum venturi assistance    When the VAS is set to the    MIN     or          position  breathing resistance is  increased    You should put it on the    MIN     or          position whenever the regulator second  stage is out of your mouth    You may put it on the    MAX     or       
6.  position whenever the mouthpiece is in  your mouth             Aova  tune    Back to the contents FURST TO DIVE       2 4 Valve Adjustment Knob  VAK     l       10       The VAK  located opposite of the hose connection on  certain model second stages  adjusts the effort required  to start the air flow at the beginning of the inhalation  cycle  As it is turned    in     clockwise   the opening effort  will increase  This will make the second stage less sensi   tive to sudden changes in ambient pressure  Turning the  knob    out     counter clockwise  will decrease the opening  effort to make breathing easier    This adjustment is particularly useful at deeper depths  or in variable conditions  that affect the opening effort of the second stage  such as strong currents or  while using a diver propulsion vehicle  DPV   It will also allow Compensation for a  difference in the hydrostatic pressure and the centre of your lungs  such as  when you are in a head down position  You can use the VAK to tune your regu   lator to maintain its peak performance throughout the course of your dive  or  you can leave it set in its mid range position and dive with as you would any non   adjustable second stage        33    2 Adjustment mm      The Dual Cam patented adjustment system combines  both the VAS and the VAK    In the         position  the VAS is maximum and the VAK is  minimum  This gives optimum performance  average   1 2j   according EN 250         In the         position   the VAS 
7.  to maintain the interior of the regulator in a clean state  see  chapter 6 Regular Care   Breathing air used in the production of a mixture  should be oxygen compatible and double filtered with a hydrocarbon content  not greater than 0 1 mg m3  Your Aqua Lung technical specialist should be  able to help you determine if the breathing air he supplies meets these criteria         Aqua LUNG    Back to the contents FIRST ho DIVE    2  INTRODUCTION    Congratulations   and thank you   for choosing Agua Lung  Your new regula   tor meets all existing standards for quality and performance and has been des   igned and manufactured with the greatest care        Perhaps  more than any other item of equipment that you have bought  the bet   ter care you take of your regulator  the better it will perform for you  Its perfor   mance will be guaranteed by regular servicing at an appointed Aqua Lung  service Centre  Before diving with your new Aqua Lung regulator it is important  that you read this manual in its entirety so that you can familiarise yourself with  its features and the rules for using the regulator before  during and after the  dive so as to retain optimum performance for the years to come     2 1 CE Conformity    This regulator has successfully passed all the tests required by the EN    2 50 2000 standard and has received certification for this type  The maximum    operating depth limit required by the standard for certifying the equipment is  o0 metres     If your regulator
8. Regulator  Owner s       AQUAZ gt  LUNG    Ri ey rOl DH YT E       Regulator Owner   s Manual       This owner s manual is protected by the law of 11 March 1957 concerning  literary and artistic property  It may not  in whole or part  be copied  photoco   pied  reproduced  without prior consent in writing from Aqua Lung        2006 Aqua Lung International  Inc   Regulator Owner s Manual  P N 127861 rev  10 07    Danger  warnings and Notes       A certain number of icons have been used in order to make this User Manual    easier to understand  They have the following meanings        DANGER indicates situations of risk or danger that could cause serious acci   dents or death if these indications are not followed correctly     WARNING indicates features or special situations in diving and aims to avoid    A risk situations     A NOTE is used to indicate information that will allow you to enjoy the best use  E  of your regulator        S Aqua LUNG    FIRST TO DIVE       Summary  to reach directly a chapter  click on the title     1 GENERAL PRECAUTION  amp  WARNINGS  1 2 ENRICHED AIR NITROX USE    1 2 1 Enriched Air Nitrox Use   Outside EEC Countries  1 2 2 Nitrox use for CEE  European Community  countries   EN 144 3 and EN 13949    2  Introduction  2 1 CE Conformity    2 2 Features   2 3 VANE ADJUSTMENT SWITCH  VAS    2 4 Valve Adjustment Knob  VAK    2 4 1 LEGEND LX Regulator   2 4 2 Kronos Second Stage Adjustment     Dual Cam       2 4 3 MIKRON Regulator   2 5 First Stage Envir
9. com     e     Aova  une    28 Back to the contents FIRST ho  DIVE    
10. ed in the United States  For warran     ties that may apply elsewhere  please contact your local representative     6  Failure to meet any of the above requirements will render the warranty null  and void          Aqua LUNG    Back to the contents FIRST ho  DIVE    8 2 Outside USA       e The operation of a regulator is guaranteed for one year from the date of pur   chase for use in sports diving non commercial  and non military     e The guarantee applies to any part found to be defective by our technical ser   vice following a manufacturing or material defect  with the exception of consu   mable parts     e The guarantee does not cover the cost of parts or labour associated with  periodic maintenance of the product  It does not cover damage caused by  incorrect use or negligence     e The operational guarantee excludes deterioration caused by normal use or  ageing of the product     e The guarantee does not apply if the product is not used or maintained in  accordance with the instructions in the user s guide supplied with the product   The guarantee will be voided by any attempt to open the regulator  all servicing  and replacement of parts should be carried out exclusively by a Spirotechnique    service agent     l  I    e The guarantee covers  at the choice of La Spirotechnique  the repair or repla   cement at our expense of defective parts  in our workshops  transport being at  the charge of the purchaser     e Replaced parts will become the property of the manufacturer
11. ement only at the discretion of Agua Lung  America  Inc     WARNING   It may be dangerous for untrained and uncertified persons to use  Atte equipment covered by this warranty  Use of SCUBA equipment by anyone   who is not a trained or certified diver  or is not currently receiving training   through a recognized certification agency  may lead to serious injury or death     This warranty gives you specific legal rights  You may have rights that vary from  state to state and country to country     AQUA LUNG AMERICA  INC  DISCLAIMS AND EXCLUDES ANY LIABILITY  FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES    Some states in the U S  and certain foreign countries do not allow exclusions or  limitations of liability for incidental or consequential damages  so this may not    apply to you               as Aqua JLunG    22 Back to the contents FIRST ho  DIVE    l      23    Restrictions       The following restrictions apply to this warranty     1  This warranty does not cover normal wear  Factory prescribed service by an  Authorized Aqua Lung Dealer is required at least once annually     2  This warranty does not extend to damages caused by improper use  impro   per maintenance  neglect  unauthorized repairs  modifications  accidents  fire   or casualty     3  Cosmetic damage  such as scratches  dents  and nicks are not covered by  this warranty     4  This warranty does not extend to equipment used for rental  commercial  or  military purposes     5  This warranty covers products purchas
12. ikron does not have a VAG  it is necessary to screw the VAK     all the way in when it is out of your mouth  Failure to do so could result in a free   flow situation should the regulator get bumped or the purge cover depressed     2 5 First Stage Environmental Protection series Titan        Kronos  Legend    supreme       For diving in cold water conditions  or commercial diving in contaminated water   Aqua Lung offers an environmental first stage protection feature that seals the  ambient chamber from the environment  This helps to prevent ice from for   ming and keeps contamination out of the main spring chamber     2 6 Registered patents      Comfobite mouthpiece  U S  Patent   4 662 903   Balanced HP seat  U S  Patent  5 746 198   Second stage thermal exchanger  U  S  Patent  5 265 596  Combined second stage adjustment for Kronos  patent applied for                ats Aqua LUNG    11 Back to the contents FIRST ho  DIVE    SS       3  PREPARATION AND SET UP    Aqua Lung America  Inc  recommends that you bring your regulator to your  Authorized Aqua Lung Dealer for the installation of any accessory items  including ins   trumentation  LP quick disconnect hoses  and alternate air sources     DANGER   Whatever the connector  when pressurizing your scuba system  be   A sure to open the cylinder valve slowly to minimize the generation of heat  Failure  to do so  with enriched air nitrox  EAN  present  increases the risk of combus   tion that can lead to serious injury or death 
13. is minimum and the VAK is  maximum  This reduces performance to the maximum allowed by EN 250  ave   rage  2 8  1   This offers a very effective pre dive position     LS N 1 Re    The VAK  located opposite of the hose connection on  certain model second stages  adjusts the effort required  to start the air flow at the beginning of the inhalation  cycle  As it is turned    in     clockwise   the opening effort  will increase  This will make the second stage less sensi   tive to sudden changes in ambient pressure  Turning the  knob    out     counter clockwise  will decrease the opening  effort to make breathing easier    This adjustment is particularly useful at deeper depths  or in variable conditions  that affect the opening effort of the second stage  such as strong currents or        k Aqua LUNG    Back to the contents FIRST ho DIVE       while using a diver propulsion vehicle  DPV   It will also allow compensation for a  difference in the hydrostatic pressure and the centre of your lungs  such as  when you are in a head down position  You can use the VAK to tune your regu   lator to maintain its peak performance throughout the course of your dive  or  you can leave it set in its mid range position and dive with as you would any non   adjustable second stage     When the VAK is completely unscrewed  counter clockwise   the regulator will  provide maximum performances    When the VAK is completely screwed  clockwise   breathing resistance is  increased     NOTE  Since the M
14. nic Mail    You can contact Aqua Lung by visiting our website at  www aqualung com          ee     Aova  une  26 Back to the contents    FIRST TO DIVE       12  ANNUAL INSPECTION  amp  SERVICE RECORD    Date Dealer Name Technician Name Observations stamp                    gt  sA oua LUNG    27 Back to the contents FIRST 10 DIVE       IMPORTANT NOTICE ABOUT MAIL ORDER SALES OF  AQUA LUNG AMERICA PRODUCTS    Beware of any retailer that offers to sell and ship our life support products by  mail  for orders placed by phone or the internet  These retailers are NOT  Authorized Agua Lung America dealers  All Authorized Agua Lung America  Dealers must execute a Dealer Agreement that does not allow the sale of Aqua  Lung America products except   in store    Many Aqua Lung dealers advertise  on the internet  but they are not allowed to deliver our products other than    over the counter    This is our assurance that you will receive the proper pre   sale  point of sale  and post sale assistance     If you obtain our product from one of these unauthorized retailers  your war   ranty is not valid and we cannot offer you the assurances of quality and satis   faction afforded by the Aqua Lung America Warranty program  If you would like  to verify whether or not a retailer is an Authorized Aqua Lung America Dealer   please call or write to Agua Lung America  Inc  using the adress or phone num   ber provided on the rear cover of this manual  Or  you can visit our website at   www aqualung 
15. onal safety and the mechanical  integrity of your regulator may depend on it         Aqua LUNG    Back to the contents FIRST ho  DIVE       8  WARRANTY INFORMATION  8 1 USA only    All warranty transactions must be accompanied by proof of original purchase from an  Authorized Aqua Lung Dealer  Be sure to save your sales receipt  and present it whe   never returning your regulator for warranty service     If any Agua Lung product that you have purchased from an Authorized Aqua Lung  Dealer fails to meet your expectations  Agua Lung America  Inc  will replace or  exchange the product free of charge within thirty  30  days of the original pur   chase  Exchanges will be made through the same Authorized Dealer for Aqua  Lung America  Inc   for merchandise of equal or lesser value  and will be made  only for Aqua Lung equipment  Agua Lung America  Inc  makes this guarantee of  satisfaction a part of all product warranties because of the confidence we have in  our products     ifetime Warr   Aqua Lung America  Inc  warrants to the original purchaser that the product  will remain free from defects in material and workmanship throughout its use      ful life  provided that it recieves normal use  proper care and prescribed dealer  service subject to those restrictions stated below              This limited warranty is extended only to the original purchaser for purchases  made from an Authorized Aqua Lung Dealer  and is not transferable  This war   ranty is limited to repair or replac
16. onmental Protection series Titan  Kronos  Legend    supreme     2 6 Registered patents    3  PREPARATION AND SET UP  3 1 Mounting the First Stage Onto the Cylinder Valve    3 1 1 Yoke Connector  3 1 2 DIN Connector or Pr EN 144 3 connector  3 2 Pre Dive Checks     3 3 Pressurising the regulator     3 4 Divisible mouthpiece    4 1  COLD WATER DIVING  5  AFTER THE DIVE    5 1 Removal of the Regulator from the Cylinder Valve  5 1 1 General Procedures  9 1 2 DIN Connector or Pr EN 144 3 connector  0 2 Disinfection    6  USER CARE  amp  MAINTENANCE  7  DEALER INSPECTION  amp  SERVICE    8  WARRANTY INFORMATION  8 1 USA only    8 1 1 The Aqua Lung Satisfaction Guarantee     8 1 2 The Aqua Lung Limited Lifetime Warranty  8 2 Outside USA   8 2 1 The Aqua Lung warranty    4  DIVING WITH THE REGULATOR    9  GUARANTEE COUPON   10  Returning Your Regulator For Service   11  Contacting Aqua Lung AMERICA via Electronic Mail  12  ANNUAL INSPECTION  amp  SERVICE RECORD      A oUa LUNG    FIRST TO DIVE          1 GENERAL PRECAUTION  amp  WARNINGS    e Before using this regulator  you must have successfully received training and  certification in the technique of SCUBA diving from a recognized certification  agency  Use of SCUBA equipment by uncertified  or untrained persons  is dan   gerous and can result in serious injury  or death     e This regulator is not configured for commercial use with surface supplied air     e Always pressurize the regulator gradually by opening the cylinder valve 
17. ou do not do this   you risk serious accident or death     DANGER   Obtain Nitrox Diving Certification   In order to gain a complete appreciation of the advantages of diving with Nitrox   it is ABSOLUTELY NECESSARY that you undergo special training and obtain cer   tification in Nitrox diving from a recognised training agency  The depth and time  limit of the dive depend on the oxygen content of the Nitrox mixture             Aqua LUNG  5 Back to the contents FiRST 10 DIVE          Your Agua Lung regulator has been prepared for use with Enriched Air Nitrox   EAN  where the percentage of oxygen in the EAN does not exceed 40   This is  possible because each regulator is built to a high standard of cleanliness using  EAN compatible components and lubricants  In addition  each regulator design  has passed stringent adiabatic compression testing to ensure its safety and  compatibility with increased percentages of oxygen     If it is your intention to use your new Aqua Lung regulator with Nitrox EAN  02  not to exceed 40    it is imperative that you maintain the internal cleanliness of  the regulator  See section on Care and Maintenance   If it is your intent to use  the regulator interchangeably with breathing air  the breathing air should be  oxygen compatible or    hyperfiltered    whereas the condensed hydrocarbons do  not exceed 0 1 mg m3  Your local authorized Aqua Lung dealer can help you  determine whether the breathing air that they provide meets this criterion     otanda
18. r at the time of charging  and is appropriate for your planned dive     5  Depress the purge button momentarily to ensure that sufficient airflow is pro   vided to blow out any dust or debris which may have entered the second stage     6  Put the regulator in your mouth and place the VAS in         position    for the  Mikron Regulator  unscrewed completely the VAK  counter clockwise      7  Inhale slowly and deeply from the regulator several times  The regulator must  deliver enough air for you to breathe easily without noticeable resistance                ats Aqua LUNG    15 Back to the contents FIRST ho  DIVE    3 4   Divisible mouthpiece       The Mikron for the lady is equipped with a specific mouthpiece  It will per   fectly fit the small jaw  The silicone bridge is in contact with the roof of the  mouth  if it is uncomfortable you have the opportunity to cut this bridge   Using a pair of scissors or a cutter you can cut the bridge  Just cut where  the furrow lines are            A oua LUNG  16 Back to the contents FiRST 10 DIVE       4  DIVING WITH THE REGULATOR    If the regulator is used as an alternative air source  it is recommended that you  fit a mouthpiece plug to prevent the entry of any foreign bodies while the VAS is  in         position    for the Mikron Regulator  screwed completely the VAK  clock   wise     While underwater the regulator may commence to free flow  If this happens  turn the regulator so that the mouthpiece points downward    When you place 
19. rd compressed breathing air meeting the EN 12021 standard  often  referred to as Grade E in the United States  does not necessarily meet this cri   terion  Grade E or EN 12021 breathing air may contain a certain level of hydro      carbons  including traces of compressor oils that while not considered harmful   to breathe  can pose a risk in the presence of elevated oxygen content  Passing    hydrocarbons through a valve and regulator creates a cumulative effect where  the hydrocarbons build up over time along the internal passageways of the  equipment  When these hydrocarbons come in contact with high pressure oxy   gen enriched air  they can pose a very real hazard that can lead to combustion     Therefore  if a regulator has had use with Grade E or EN 12021 breathing air   it should be returned to an authorized Aqualung dealer for overhaul service  including hydrocarbon cleaning  prior to being put back into nitrox service     Although second stage components are not exposed to high pressure EAN   Aqua Lung recommends that the same cleaning procedures be followed for the  complete regulator  This prevents the possibility of cross contamination and  guarantees the cleanliness of the entire regulator             ats Aqua LUNG    Back to the contents FIRST ho  DIVE    _   _    E  E    A          In CEE countries  diving with Nitrox Oe2 is controlled by Standards EN 144 3    Respiratory protective devices   Gas cylinder valves   Part 3  Outlet connections  for diving gases Nit
20. rnal damage     3  Visually inspect the mouthpiece to ensure that there are no tears or splits   4  Check that the needle of your submersible pressure gauge Is on zero     5  Check that your VAS or Dual Cam is set to        For the Mikron Regulator   check that your VAK is screwed  see chapter 2 4 3      6  Fit your regulator to the cylinder  see Chapter 3 1   checking that the hoses  are oriented correctly             k Aqua LUNG    Back to the contents FIRST ho  DIVE    3 3 Pressurising the regulator       DANGER   Before pressurizing the regulator check the condition of the hoses  fitted to the regulator     1  If a submersible pressure gauge is fitted check that its dial faces  away from you     2  SLOWLY open the cylinder valve by unscrewing to pressurize the regulator   When the valve is completely open  screw it back a quarter turn     3  Check that there are no leaks from any of the hoses or from any other acces   sories fitted  NEVER DIVE with a regulator that shows any leaks when placed  under pressure  If there is a leak between the regulator and the cylinder check  that the regulator is correctly fitted and that the O ring is in good condition     under pressure  If they are not correctly oriented  purge the regulator and      i WARNING   Never attempt to reposition the hoses once the regulator is    reposition them          L    4  Check to ensure that the submersible pressure gauge is displaying an accu     rate measurement of the air pressure inside the cylinde
21. rox and oxygen   and EN 13949   Respiratory equipment    Open circuit self contained diving apparatus for use with compressed Nitrox  and oxygen   Requirements  testing  marking     NOTE   The maximum depth of the dive is determined by the type  of mixture used     NOTE   Aqua Lung offers a range of regulators designed and manufactured spe   cially for use with oxygen enriched mixtures  over 21  and up to 100  oxygen   This range has been certified according to the EN 144 3 and EN 13949 stan   dards and meets the requirements of the adiabatic compression tests  They  have received CE certification for this type  For further information on this range   contact your Aqua Lung specialist centre     DANGER   These regulators fitted with special connections should be used only     with complementary equipment  tank valves  tanks  pressure gauges  etc   des   igned and prepared for use with an oxygen enriched mixture  These items are  marked Nitrox Qe2     DANGER   If the regulator that you use is fitted with a yoke or DIN connection  it  is designed for use only with compressed breathing air  21  oxygen and 79   nitrogen  which meets the EN 12021 standard  DO NOT USE this equipment  with other mixtures or with gases containing more than 21  oxygen   Disregarding this rule could result in serious accident or death caused by fire or  by an explosion     Every Nitrox O2 regulator is assembled in a clean workshop  using compatible  components and special lubricants     It is important
22. t is still connected to the cylinder valve     DANGER   Do not use any type of solvent or petroleum based substances to  A cican or lubricate any part of the regulator  Do not expose any part of the regu    lator to aerosol spray  as some aerosol propellants attack or degrade rubber    and plastic materials          S Aoua LUNG    20 Back to the contents FIRST ho  DIVE    l         21       7  DEALER INSPECTION  amp  SERVICE    It cannot be assumed that a regulator is in good working order on the basis  that it has received little use since it was last serviced  Remember that prolon   ged or improper storage can still result in internal corrosion and or deteriora   tion of O ring seals     You must obtain factory prescribed service for your regulator at least once a  year from an Authorized Aqua Lung Dealer  regardless of the amount of use it  has received  Your regulator may require this service more frequently  depen   ding on the amount of use it receives and the environmental conditions in which  it is used     lf the regulator is used for rental or training purposes  it will require complete  overhaul and factory prescribed service every three to six months  Chlorinated  Swimming pool water is an especially damaging environment for SCUBA equip   ment  due to the high levels of chlorine and pH balancing chemicals that cause  certain components to rapidly deteriorate     Obtain service for your regulator at least once a year  from an  Authorized Aqua Lung dealer  Your pers
23. the regulator in your mouth put the VAS in position         to  obtain maximum breathing comfort  For the Mikron Regulator  unscrewed com   pletely the VAK  counter clockwise      4 1  COLD WATER DIVING      In order to reduce the risks of regulator freezing when diving in cold water   below 50  F or 10  C   consider at least the following recommendations and  respect your dive training program procedure      1  Protect your regulator from any accidental entrance of water into the first    or second stages     2  Protect your equipment from cold before the dive  More precisely  keep your    regulator and all its accessories in a warm dry place     3  Carry out all pre dive checks of your equipment in a warm dry place  before  even going to the dive site     4  Avoid breathing through the regulator or pressing the purge button in very  cold air before entering the water     5  Avoid removing the regulator from your mouth during the dive  or when on  the surface  This will prevent cold water from entering the regulator second    stage     6  As far as Is possible  avoid excessive effort during the dive     7  Have your dive store check that the air in your cylinder meets EN 12021  and is is dry               as Aqua JLunG    Back to the contents FIRST ho  DIVE       5  AFTER THE DIVE  5 1 Removal of the Regulator from the Cylinder Valve    NOTE   If fresh water is available  rinse your regulator completely before depres      surizing it  This will help to prevent any contaminan
24. tion of glutaraldehyde produced by the Anios company  Sterianos  Agua Lung  reference 362062  following the procedure described on the package             Aqua LUNG    18 Back to the contents FIRST ho DIVE       l          6  USER CARE  amp  MAINTENANCE    It is important to provide the proper preventative maintenance in order to  ensure the best possible performance and maximum life of your Agua Lung  Regulator  The following maintenance procedures should be performed routi   nely after each use to ensure that the regulator is cleaned  inspected  and pre   pared for the next use or for storage     As soon as possible after diving  the regulator should be rinsed thoroughly with  fresh water while it is attached to a cylinder and pressurized with air     Rinsing alone  however  will not sufficiently clean the regulator  To clean the  regulator as thoroughly as possible Agua Lung recommends       Attach the regulator to a charged SCUBA cylinder  open the cylinder valve to  pressurize the regulator  and thoroughly soak both the first and second stages  in a bath of fresh water       While the regulator is soaking  move the vane adjustment switch on the   second stage  if present  back and forth several times from the    MIN     or            to the    MAX     or        settings  You may also turn the valve adjustment knob   adjustable models  slightly back and forth   no more than 1 4 turn     After the regulator has been properly soaked  It is important to rinse It vigo   rousl
25. ts from entering sealing sur   faces inside the regulator     NOTE   When you remove the regulator from the cylinder take care to prevent     the entry of water into the regulator  particularly via the filter     1  Shut off the cylinder air supply by turning the cylinder valve handwheel clock   wise until it stops    2  While observing the submersible pressure gauge  depress the purge button  of the second stage  When the gauge reads zero and airflow can no longer be  heard from the second stage  release the purge button          Pr EN 144 3 co           1  Turn the yoke screw counter clockwise to loosen and remove the first stage  from the cylinder valve   2  Dry the dust cap with a towel or other lint free cloth  While you may use air  from your tank valve to blow the water off the dust cap  you run the risk of blo   wing water into the filter   3  Place the dust cap over the first stage inlet fitting and seal it securely in  place by tightening down the yoke screw   4  Completely screw home the DIN handwheel onto the dust cap   5  With the cylinder valve facing away from you  open the valve slightly to  release a short burst of air  and then immediately close the valve  This will clear  any moisture that may have entered the valve opening  Immediately seal the  protector cap securely in place over the opening of the DIN valve to prevent the  entrance of moisture or debris     5 2 Disinfection    Aqua Lung recommend disinfecting the regulator second stage with a 2  solu   
26. y by flushing the mainspring cavity of the first stage regulator  non environ   mentally sealed models only   the second stage mouthpiece  and the openings  in the second stage front cover with a pressurized stream of water  This will  remove the deposits of salt and minerals that were loosened during soaking     DANGER   if you use a garden hose  do not use the high pressure Jet as this  could damage the diaphragm and the internal valve     WARNING   DO NOT depress the purge button  loosen the first stage yoke  screw  or turn the second stage adjustment knob all the way    out     adjustable  models  if the regulator is submerged unpressurized  Doing so will allow the  entrance of moisture  and will require that the regulator be returned to an  Authorized Aqua Lung Dealer for service             as Aqua JLuNG    Back to the contents FIRST ho DIVE       e Disconnect the regulator and wipe itr as dry as possible and then hang it by  the first stage to ensure that all remaining moisture drains from the second  stages     e Do not leave the regulator exposed to direct sunlight for long periods     e When the regulator is completely dry  store in a clean equipment box  or sea   led inside a plastic bag  Do not store it where it may be exposed to extreme  heat or an electric motor  which produces ozone  Prolonged exposure to  extreme heat  ozone  chlorine  and ultraviolet rays can cause premature degra   dation of rubber parts and components     e Never store the regulator while i
    