Home

Instructions (PDF format)

image

Contents

1. The WT 009 also comes with additional 1 Input and 1 Output The output is connected to an on board relay which can be activated by sending an SMS command The Input can be used to generate alarms when triggered It also can be programmed to count the input active pulses up to 1ms fast or activate the output relay Note When used as counters input work only in ACTIVE HIGH mode they count ONLY High Going Pulses 5 1 I nput Settings One of the most important functions is to receive alarms In order to do this properly you must program the administrator numbers turn on the function of the input and tell the WT 009 which are the recipient numbers and who should receive the alert message for the particular input 5 1 1 Programming the Administrator Number The 8 administrator numbers can be programmed with a text command via SMS Text Command TEL N XXXXXXXXXX N stands for administrator number 1 8 position XXXXXXXXXX stands for the phone number you want to program as administrator e To add a number the syntax of the command is the following PWD123456 TEL1 3593334444 Example of Returned Message TELL 3593334444 Please note that it is possible to program up to a maximum of 16 digits for a number e To check all the administrator number in the list PWD123456 TEL Example of Returned Message TELL 3593334444 TEL2 0000000000 TEL3 0000000000 TEL4 0000000000 TELS 0000000000 TEL6 0000000
2. WT 009 GSM Dial to Open Device User Manual Dial2 pen WT 009 USER MANUAL y K l i gz Y gt oe o 4 os eas p i 7 s gS SEvieT at e ax AVS ae 6 se r E e t arere app my e Ea 1a f z gt ee FERIETAN S ie Electronic KIT to convert your gate into a GSM gate New Dial2Open WT009 2 Output 1 Input 2D lt OS amp Specifacations 2 Output Relays 240 Volts 1 Amp 1 Opto Coupler Alarm Input 12 24 Volts AC DC K 64 Caller ID Users ow C E raaskit m powes a A N G off Power and Connection Port Left Port Right Port 12 2 On Off Switch Power LED Network LED Sim Card Aerial Connector 4 Volts AC DC Normaly Open Dry Contacts connect the 2 wires of the relay contact in parallel with the gate opening button Common Ground Hormally Closed Contact and turns to Open Contact when activated Normally Opened Contact and turns to Close Contact when activated Alarm Input apply 12 Volts to activate text alert copyright dialZopen International 2008 WT 009 Dial to Open Device Diagram VEO GUICTION roana eeen i E et aaaan ATETA Advantages of WT 009 Dial to Open De VICE 0 acca esc nem ememtmemsmememenenememememes WT 009 Dial to Open Device Operating INStrUCTION 6 cen en ene emememrusmenens U AA U N e Sle INPUT CLI OS aran A A a 5 1 1 Programming the Administrator NUMDbeEr m a msmemememsmemememememenmenenrnen 5
3. PWD and it can be changed anytime with CAP command Example e To reset the unit with default password 123456 the syntax of the command is the following REST 123456 Returned Message REST OK 17 5 4 Reset the WT 009 Method 2 To reset the unit using this method you will need to supply a DC 12 40V at the input and turn on the unit The network LED will stay lit for 1 3 seconds and off Once the network LED stops lit the DC power supply at the input needs to disconnect immediately in order to successfully reset the unit Power an conne cigi Left Port 3 1 Er Turn On the unit when Network LED will there is a Stay lit for 1 3 voltage at the seconds and off input 12 24 Volts ACDC Ground Connect a DC 12 40 olts at the input 5 5 Auto Restart System The WT 009 can continuously monitor the system status of its own When there is a problem with system operation or the module is not working properly it will restart the system automatically to avoid the unit stopped working After 15 seconds of system failure it will restart the system for 30 seconds and then the system will be ready to use 18 Some phones cannot open the gate Verify that they send the caller ID when calling another phone Check that the number you ses in the othar phena is what you have programmed in the Dial to Open Device have inserted the SIM but the unit doesn t work Check to have
4. 1 2 Setting the Recipient that will Receive Alert Messag 0 0snsnenenes 5 L3 Editing the AICIE MeESSAge ideas iene aawaineeuten erate ra a a 5 1 4 Turn On the Function of NPU n seurnrmrninininsnrminrmrminsa annnm 5 1 5 Setting the Counter Alert Value for INPUt 0 cucu ewes emememememenen 5 1 6 Setting the Feature for INpUt n m mememenmenenimimimimeneninimimimrmememenrnrm 5 1 7 Reading the Total Increment Counter ValUe am m m emea eures orm rmrm emenn 5 1 8 Reading the Sub Increment Counter ValUe m m mememenmememrmrmemrmenenen 5 1 9 Reset the Total Counter ValUe m msmsninininininininininininininimimimemse S 2e OULDUL SCENO S e aaa aa a 5 2 1 Activate the Output Relay to Stay On for a Specific Time 0 000 5 2 2 Activate the Output Relay to Stay ON s m m mememememenmemimimimrmrneneninrm 5 2 3 Setting the Output Relay 2 to Supply Voltage or use Dry Contact 5 34 RESEE the WT 009 Method J cx ons ssae cient eee date EENE E 54 Reset Ine WI 009 MEENOG 2 ca dasnncuhndeas dives aaa SILAM ROS oy S LON rsa aa a e EETA 6 Most common problems and solutiOnS m m mes ememr rmnm ememoorsrmrmrmrmemememememrmrmne JW T 0009 Programming NStLUCHIONS i iii istdewnamnanun seen ee e a E Additional Input amp Output Programming INStruUCtiOnNS s a a eneun saeua an ene em emememememens 1 Introduction Dial to open Device is an electronic board manufactured by Witura Corporation
5. Sdn Bhd that links to a SIMCOM 300 GSM module supplied with it The purpose of this device is to be installed in parallel of the low voltage opening button of an electric gate to enable it to be opened by means of a GSM phone It has a relay whose contact has to be connected in parallel with the button which opens the gate It has a White List of numbers who are enabled to open the gate up to 99 When the Dial to Open Device receives a call it will check to see if the calling number is in the list If it is in the list it will reject the call so there will be no charge at least with today s charging procedures and click the relay momentarily 2 Advantages of WT 009 Dial to Open Device 1 Safe nobody can clone your phone as easily as they can do with a standard remote control 2 Flexible you can add or remove anybody number in a minute with an SMS 3 Cheap you don t need to buy a remote control for each member of your family 4 Convenient no matter if you change car or if you have different gates to open Your phone will always be with you all the times your remote controls were somewhere else 3 WT 009 Dial to Open Device Operating Instructions Installation To install the Dial to Open Device you need to connect the 2 wires of the relay contact in parallel with the gate opening button The relay contact can stand 48V 1A maximum this is enough for its operation but_don t try to
6. the relay has turned on off This is to notify the administrators when someone outside the list activates the relays 15 5 2 2 Activate the Output Relay to Stay On To activate the output relay to stay on you can send the following commands by SMS message to the unit Text Command RLOP N X N stands for number 1 or 2 of Output X stands for ON 1 or OFF 0 value e To activate the output relay number 2 to stay on indefinitely the syntax of the command is the following PWD123456 RLOP2 1 Returned Message RLOP2 ON Note The reply message will be send to the recipients The Administrators only when the relay has turned on off This is to notify the administrators when someone outside the list activates the relays 5 2 3 Setting the Output Relay 2 to Supply Voltage or use Dry Contact when Activated To set the output relay 2 to supply DC voltage when activated please adjust the jumper according to the below diagram 16 Note Relay 2 will supply DC voltage only according to the output DC voltage of adapter used When 24VAC adapter is used the voltage supplied would be 33VDC To set the output relay 2 to use dry contact Default when activated please adjust the jumper according to the below diagram 5 3 Reset the WT 009 Method 1 To reset the unit you can send the following SMS command to the unit Text Command REST XXXXXX XXXXXX stands for 6 digits password based on
7. 000 TEL7 0000000000 TEL8 0000000000 Note Programming the administrator numbers is necessary in order to operate all the below functions and to receive text alerts when the relays activated 5 1 2 Setting the Recipient that will Receive Alert Message The unit can only send text alerts to 1 or all 8 of the programmed administrator s mobile phone numbers and this function can be changed at any time by sending the following commands by SMS message to the unit Text Command 10 RERN XXXXXXXX XXXXXXXX stands for 8 digits value ON 1 or OFF 0 for the 8 administrators For example if we assume only administrators 1 2 3 and 4 are to receive text alerts you would send the following SMS message to the unit e PWD123456 RERN 11110000 Example of Returned Message RERN 11110000 Note You can only put 1 in the first 4 digits of the text command if there are only phone numbers stored in TEL1 TEL2 TEL3 and TEL4 The rest should be 0 e To check the setting of which recipient will receive alert messages PWD123456 RER Example of Returned Message RERN 11110000 5 1 3 Editing the Input Alert Message The Input Alert Message can be edited and programmed up to 100 characters long You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command STR XXXX x XXXXX stands for the di
8. 6 WHL01 3593334444 Where 01 is the position in the list and 3593334444 is the number enabled Please note that it is possible to program up to a maximum of 10 digits for a number If it has more digits you should use the rightmost ones For example if your number is 33446665555 you should program 3446665555 If your number appears as 393489999888 you should not program the country code 39 If your number has only 9 digits or less it is not a problem The important thing is that you don t exceed 10 digits e To check which is the number in a place of the list PWD123456 WHLO1 Example of Returned Message WHLOL 3446665555 e To erase a number PWD123456 WHLOLD Returned Message WHLO1 OK e To erase all number PWD123456 WHLIID Returned Message DELALL OK Note To erase the number stored in place 99 in the list only you would send the command PWD123456 WHL99 0000000000 ACM Access Mode This command allows you to open only to people that are in the white list or to anybody calling the SIM number e PWD123456 ACMO0 it is a zero Warning With the above command you allow free access to anybody calling Returned Message ACM OFF e PWD123456 ACM2 With the above command you allow only people that are in the white list and administrator list This is the standard and recommended option Returned Message ACM ON CAP Change Password Use this command to change the password with a new one that y
9. counter value you can send the following SMS message to the unit Text Command COT The syntax of the command is the following PWD123456 COT You will receive the sub increment value from the unit by SMS Example of Returned Message COT 00015 Note The sub increment counter value will be reset automatically each time the alarm counter reached the alert value 5 1 9 Reset the Total Counter Value To reset the total counter value you can send the following SMS message to the unit Text Command 14 e The syntax of the command is the following PWD123456 CLA Example of Returned Message RECO OK 5 2 Output Settings 5 2 1 Activate the Output Relay to Stay On for a Specific Time To activate the output relay you can send a text command via SMS specifying the number of seconds the output should stay on to the unit It is possible to set up to maximum of 65 535 seconds Text Command RLY N XXXXX N stands for number 1 or 2 of Output XXXXX stands for 5 digits value The number of seconds For example assume you want to turn on the output relay number 2 for 1 hour you would send the following SMS message to the unit e PWD123456 RLY2 03600 Example of Returned Message RLY2 03600 e To check the status of output relay PWD123456 RLY Example of Returned Message RLY1 03580 RLY2 00000 Note The reply message will be send to the recipients The Administrators only when
10. ou will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be sure you don t digit a wrong one Of course it must be preceded by the old password For example to change the password 123456 into the new password 333444 you need to send the following SMS e PWD123456 CAP333444 CAP333444 Example of Returned Message CAP 333444 GOT Gate pulse time This command is useful in case you need to keep the button pressed longer The standard time is 1 second Maximum 99 seconds You can change it with the GOT command The syntax of the command is the following e PWD123456 GOTO2 With the above command the opening time has been set to 2 seconds Returned Message GOT 02 CSQ Check GSM signal quality This command is useful to see what is the GSM network signal level your Dial to Open Device is receiving If you send the command PWD123456 CSQ You should receive an SMS with signal quality in range O to 31 if it is O we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external antenna if this is not the case or eventually even change operator with another that serves your area better Example of Returned Message CSQ lt 21 gt Additional I nput amp Output Programming I nstructions
11. put you can send the following commands by SMS message to the unit Text Command CTC F F stands for input function 1 5 Function Descriptions Function Ll Function as counter Sends a counter alert message once alarm counter reaches the alert value Function 2 Function as counter Activate the output relay 2 to stay on Sends a counter alert message once alarm counter reaches the alert value Function 3 Function as counter Activate the output relay 2 to stay on Sends an alert message once triggered Sends a counter alert message once alarm counter reaches the alert value Function 4 Function as counter Activate the output relay 2 for 1 second Sends a counter alert message once alarm counter reaches the alert value Function 5 Sends an alert message once triggered For example assume you want it to send an alert message each time the input triggered you would send the following SMS message to the unit e PWD123456 CTC 5 Example of Returned Message CTC lt 5 gt 13 5 1 7 Reading the Total Increment Counter Value To read the total increment counter value you can send the following SMS message to the unit Text Command COU 5 1 8 Reading the Sub Increment Counter Value The syntax of the command is the following PWD123456 COU You will receive the total increment value from the unit by SMS Example of Returned Message INC 00015 To read the sub increment
12. removed the PIN request from the SIM If you didn t do it and you have switched on the unit more than 3 times you may need to use the PUK Check with SIM instructions for details have checked in all possible ways but still the unit doesn t work Try to change operator Is it possible to open to anybody Yes you can do it using the ACM command Please be aware that some networks will disable a SIM if it is not used to make a call or send a text message over a period of time please check with your network Lg
13. splay text that you want to program For example if you want the alert message to display Garage Opened when received a text alert you would send the following SMS message to the unit e PWD123456 STR Garage Opened Example of Returned Message String Garage Opened 11 5 1 4 Turn On the Function of Input To turn on the function of input you can send the following commands by SMS message to the unit Text Command CTR X X stands for ON 1 or OFF 0 value e To turn on the input the syntax of the command is the following PWD123456 CTR 1 Returned Message CTR lt 1 gt 5 1 5 Setting the Counter Alert Value for I nput An alert message will be sent when the increment of alarm counter reaches the alert value Default 500 It is possible to set the alert value up to maximum value of 65535 times To set the counter alert value of input you can send the following commands by SMS message to the unit Text Command COA XXXXX XXXXX stands for 5 digits value The number of times For example assume you want it sends a counter alert message each time the input has triggered for 5 times you would send the following SMS message to the unit e PWD123456 COA 00005 Example of Returned Message COA 00005 5 1 6 Setting the Feature of Input This input can be programmed to behave differently it can count the input active high pulses generate an alarm message or activate relay To program the in
14. switch higher voltages or currents You also need to provide the power by means of 12 to 24 VAC or 12 to 24 VDC The power supply must be able to supply 2 4 Amps DO NOT USE A GATE CONTROL PANEL AS THE POWER SUPPLY Don t use telephone battery chargers Most of them rely on the phone battery and are unable to supply the power needed You should install the WT 009 Dial to Open Device in a place where there is GSM signal coming from the operator you want to use Check it with a phone before proceeding with the installation If you need to install the device in a place with little signal you may consider using an external antenna that we may supply as an option to be purchased separately with 5m cable You should then insert the SIM of the operator you want to use and program in the White List the numbers enabled to open the gate using the command WHL Note You must remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work In order to do so insert the SIM ina phone and disable the PIN request usually there is a security menu that enables you to do so If you don t do it and switch on the unit more than 3 times you will have to reset the PIN using the PUK 4 WT 009 Programming Instructions You can program the WT 009 with SMS commands using your phone It is safe to do SO because in addition to the fact that other people may not know the number of the SIM inserted in it
15. we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character Attention Please program the WT 009 unit systematically begin with programming the white list first The 2 SMS commands that you will certainly use in the Dial to Open Device are the following PWD Password WHL White List add or remove numbers You could also use the following though not necessarily ACM Access Mode CAP Change password GOT Gate pulse time CSQ Check Signal Quality Once you issue a command with an SMS you will receive a confirmation SMS PWD Password This command must always come first Use 6 digits as a password The standard default one when the device comes from the factory is 123456 We suggest that you change it using the CAP command In all the following examples we will use 123456 as an example of password WHL White List This is the command that you will use most It is used to add or remove numbers that are enabled to open the gate into the White List You can add up to 99 numbers in the list Every position must be indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position VN 009 U R MANUA e To add a number the syntax of the command is the following PWD12345

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Galaxy Tab 3 Lite (7.0, 3G) Керівництво користувача  Philips AZ2558  Avaya Activity Reporter User's Manual  ENVELOPE FEEDER AMC-2000-16 FOR HAMADA RS34 / VS34  Instruções para Carrinho de Bebê Multifuncional Liberty  Bedienungsanleitung Kommunal (320 - 1.000 kW)  Inter-Tech CI-01  Intel Server Board SE7501BR2 Motherboard  IMPLANTABLE PORT SYSTEMS  Avaya IP Phone 2007 Getting Started for Communication Server 1000 Getting Started Manual  