1. Contact Information USA Canada 1 800 800 4272 Mexico 292 0253 292 0255 Brazil 0800 12 72 1 Worldwide 1 401 789 5735 Internet http www apc com Technical Support http www apc com support Copyright 2000 American Power Conversion All rights reserved
2. the Battery under Installation on the front page of this document It shows how to access the battery and connect the wires The Overload indicator is lit if equipment connected to the Battery Backup outlets is drawing more power than the Back UPS can pro vide Move one or more equipment power plugs to the Surge Only outlets Battery requires replacement The battery should be replaced within two weeks see Order Replacement Battery Failure to replace the battery will result in reduced run time during a power outage Red indicators are flashing Back UPS failure Call APC for service Replace Battery indicator lit and an alarm sounds when the Back UPS is turned on Internal battery not connected Check the battery connections Specifications Input Voltage on line 180 264 Vac default setting Frequency Limits on line 47 63 Hz autosensing On Battery Waveshape Stepped Sine Wave Maximum Load 350 VA 210W 500 VA 300 W Typical Recharge Time 8 Hours Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 5 to 45 C 23 to 113 F Operating and Storage 0 to 95 non condensing Relative Humidity Size H x W x D 16 5x9 2x28 5cm 6 5 x 3 6 x 11 2 inches Weight 350 VA 6 3 kg 13 8 Ibs 500 VA 13 8 lb 6 3 kg Shipping Weight 350 VA 7 0 kg 15 3 kg 500 VA 15 3 lb 7 0 kg EMI Classificatio
3. the date purchased Be prepared to troubleshoot the problem over the telephone with a technician If this is not successful the technician will issue a Return Merchandise Authorization Number RMA and a shipping address e Ifthe UPS is under warranty repairs are free If not there is a repair charge 4 Pack the UPS in its original packaging If the original packing is not available ask customer ser vice about obtaining a new set Pack the UPS properly to avoid damage in transit Note Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty insuring the package for full value is recom nn Write the RMA on the outside of the package Return the UPS by insured prepaid carrier to the address provided by customer service a Warranty The standard warranty is two 2 years from the date of purchase APC s standard procedure is to replace the original unit with a factory reconditioned unit Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative APC will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to APC APC pays ground freight transportation costs to ship the replacement to the customer APC
4. tripped Disconnect non essential equipment from the Back UPS Reset the circuit breaker located on the rear panel of the Back UPS by push ing the circuit breaker button fully inward until it catches aan The wall outlet that the Back UPS is connected to does not supply utility power to the unit Connect the Back UPS to another wall outlet or have a qualified electrician check the building wiring Back UPS does not provide expected backup time Back UPS is excessively loaded Unplug non essential Battery Backup connected equipment such as printers and plug them into Surge Only outlets Note Devices that have motors or dimmer switches laser printers heaters fans lamps and vacuum cleaners for example should not be connected to the Battery Backup outlets Back UPS battery is weak due to recent outage and has not had time to recharge Charge the battery The battery charges whenever the Back UPS is connected to a wall outlet Typically eight hours of charging time are needed to fully charge the battery from total discharge Back UPS run time is reduced until the battery is fully charged Battery requires replacement Replace battery see Order Replacement Battery Batteries typically last 3 6 years shorter if subjected to frequent power outages or ele vated temperatures A red indicator is lit Battery is not connected properly Check the battery connections Consult Connect
5. Switch on the Back UPS Note Allow the Back UPS to charge for a full eight hours prior to use Press the push button on the front panel of the Back UPS Xz ON LINE J ON BATTERY C OVERLOAD REPLACE BATTERY Observe that the following events occur after pressing and releasing the push button The green On Line indicator flashes e The yellow On Battery indicator lights while the Self Test is being performed e When Self Test has successfully completed only the green On Line indicator will be lit e Ifthe internal battery is not connected see Step 1 above the green On Line indicator and red Replace Battery indicator will light The Back UPS will also emit a chirping sound There are four status indicators lights on the front panel of the Back UPS On Line On Battery Overload and Replace Battery lt gt Xz ON LINE es AU ON BATTERY C OVERLOAD REPLACE BATTERY On Line green is lit whenever utility power is powering the Battery Backup outlets On Battery yellow is lit whenever the battery of the Back UPS is powering equipment connected to the Battery Backup Outlets Ag gt Four Beeps Every 30 Seconds this alarm is sounded whenever the Back UPS is running On Battery Consider saving work in progress Continuous Beeping this alarm is sounded whenever a low batt
6. ery condition is reached Battery run time is very low Promptly save any work in progress and exit all open applications Shutdown the operating Placement Power Avoid placing the Back UPS in e Direct sunlight e Excessive heat e Excessive humidity or in contact with fluids of any type died 0 oo Plug the Back UPS into a wall outlet as shown Your computer s power cord e The Back UPS charges the internal battery any time it is connected to a wall outlet Connect Equipment to the Back UPS The rear panel of the Back UPS consists of the following elements Battery Back Up Outlets qty of 3 These outlets provide battery back up surge protection and Electro magnetic Interference EMI filtering In case of power outage battery power is automatically provided to these outlets Power utility or battery is not supplied to these outlets when the Back UPS is switched Off Connect a computer monitor and external disk or CD ROM drive to these outlets Surge Only Outlet This outlet is always On when utility power is available and is not controlled by the On Off switch This outlet does not provide power during a power outage Connect a printer fax machine or scanner to this outlet Connect the Phone Line to Surge Protection The telephone ports provide lightning surge protection for any device connected to the telephone line computer modem fax or telephone The telephone port
7. he Run option Type lt CD ROM drive letter gt setup exe To replace the internal battery proceed as follows Mac OS 9 9 0 4 or higher Users APC Shutdown Manager software has been designed specifically to work with Mac OS 9 9 0 4 or higher except OS X There are builds of the Mac OS prior to Mac OS 9 0 4 with power drivers that have known problems Ensure that the most up to date version of Mac OS 9 9 0 4 or higher is installed on the system Insert the APC Installation CD ROM with the APC Shutdown Manager software into the CD ROM drive An icon called APC Shutdown Manager v1 0 will appear on the computer desktop Open the folder and double click the ReadMe file Ensure that the computer s hardware matches the requirements stated in the ReadMe file Double click on APC Shutdown lt Manager v1 0 to begin the installation of the software At the first dialog click on Continue Read the displayed license agreement and click Accept to agree to the terms Click on Install to begin After installation click on the Restart dialog button to restart the computer All Other Users The software is designed for the Windows and Macintosh operating systems mentioned in this section If one of these operating systems is not installed on the computer the Back UPS will still provide these primary features Battery backup surge protection and telephone line protection
8. n EN 55022 IEC 801 2 and 801 4 level IV and IEC 801 3 level HD On Battery Run Time 20 Minutes typical desktop computer and 15 inch 38 1 cm monitor Order Replacement Battery The typical battery lifetime is 3 6 years depending on the number of discharge cycles and operating temperature A replacement battery can be ordered over the phone from APC or the battery can be ordered on line from the APC web site see below a valid credit card is required When ordering please specify Battery Cartridge RBC2 In situations where the Back UPS or connected equipment appears too sensitive to input voltage it may be necessary to adjust the transfer voltage This is a simple task requiring use of the front panel pushbutton To adjust the transfer voltage proceed as follows 1 Plug the Back UPS into the utility power source The Back UPS will be in a Standby Mode no indicators lit 2 Press the front panel pushbutton fully inward for 10 seconds All indicators on the Back UPS will flash to acknowledge going into Programming Mode 3 The Back UPS will then indicate its current Lower Transfer Voltage as shown in the following table Indicators Lit Lower Transfer Voltage Use When 1 160 VAC Back UPS frequently goes On Battery due to low input voltage 2 180 VAC factory default Normal power conditions exist 3 196 VAC Connected equipment is sensitive to low voltage To select 160 vol
9. ng Windows Me For Windows 98 after connecting the USB cable the Add New Hardware Wizard dialog box is displayed Insert a Windows 98 operating system CD into the computer CD ROM drive before proceeding 2 Follow the installation instructions on the computer screen During installation Windows will need to search for new drivers When prompted make sure the CD ROM drive box is checked Overload red is lit whenever power demand has exceeded the capac ity of the Back UPS x lt Continuous Tone this alarm is sounded whenever the Battery Backup outlets are overloaded Circuit Breaker the circuit S A breaker button located on the rear er 8 panel of the Back UPS will stick 45 out if an overload condition forces the Back UPS to disconnect itself from utility power If the button sticks out disconnect non essential equipment Reset the circuit breaker by pushing the button inward Replace Battery red is lit when xX ever the battery is near the end of its use ful life or if the battery is not connected see above A battery that is near the end of its useful life has insufficient run time and should be replaced this alarm is sounded whenever the Z Chirps for 1 Minute Every 5 Hours failed the battery has automatic diagnostic test 3 After installation of the drivers is complete a Windows 98 CD ROM dialog box may appear If this happens j
10. s are compatible with Home Phoneline Networking Alliance HPNA and Digital Suscriber Line DSL standards as well as all modem data rates Connect as shown Wall Outlet Modem Phone Fax Connect USB Cable and Install Software optional Note The Back UPS software CD ROM provides data reporting and unattended shutdown of computers connected to the device The User s Guide contains additional information about the Back UPS software The User s Guide is contained in the main folder with the CD ROM Attention USB Hubs The Back UPS should be plugged into the USB port of the computer not into a USB hub The computer must be powered On before connecting the USB cable Connect the USB cable end USB symbol facing down to the rear panel USB port of the Back UPS Connect the other end of the USB cable to the USB port usually located on the rear panel of the computer Windows 98 and Windows Me Users The APC Power Management Extensions software has been designed specifically to work with Windows 98 build number 4 10 1998 Windows 98 SE Second Edition 4 10 2222A and Windows Me Millennium Edition To ascertain the build number go to the Control Panel open the System dialog and view the System information under the General tab of the dialog To install the software perform the following steps 1 Please skip to step 4 if runni
11. th problems that cannot be resolved using this document Possible Cause Procedure Back UPS will not switch on Back UPS not connected to an AC power source Check that the Back UPS power plug is securely connected to the wall outlet Back UPS circuit breaker tripped Disconnect non essential equipment from the Back UPS Reset the circuit breaker located on the rear panel of the Back UPS by push ing the circuit breaker button fully inward until it catches If the circuit breaker resets switch the Back UPS on and reconnect the equipment one at a time If the circuit breaker trips again it is likely that one of the connected devices is causing the overload Very low or no utility voltage Check the wall outlet that supplies power to the Back UPS using a table lamp If the lamp bulb is very dim have the utility voltage checked by a qualified electrician Back UPS does not power computer monitor external drive during an outage Internal battery is not connected Check the battery connections See Connect the Battery under Installation on the front page of this document Computer monitor or external disk CD ROM drive is plugged into a Surge Only outlet Move computer monitor or external drive power cord plug to the Battery Backup outlets Back UPS operates on battery although normal utility voltage exists Back UPS circuit breaker
12. to protect the entire desktop from lightning and power surges Runtime needed to work through brief power disturbances This allows time to manually save data and shut down safely The disabled features include Unattended Automatic Operating System Shutdown and Application Data Saving Status Indicators and Alarms Replace the Internal Battery Note Replacing the battery is a safe procedure However small sparks may occur during the process This is normal Place the unit on its side Slide the battery compartment cover upward and off of the UPS Pull the battery out exposing the battery terminals and wires Disconnect the wires from the terminals Slide the new battery into the battery compartment Connect the battery wires to the terminals as follows Black wire to Ground terminal Red wire to Positive terminal Align the battery compartment cover with the grooves system computer and the Back UPS nes in the UPS Slide the cover down until it locks APC Back UPS and PowerChute plus are registered trademarks of American Power Conversion All other trademarks are property of their respective owners Troubleshooting Transfer Voltage Adjustment optional Use the tables below to solve minor Back UPS installation and operation problems Consult APC On line Technical Support or call APC Technical Support for assistance wi
13. ts as the Lower Transfer Voltage press the pushbutton until 1 indicator is flashing To select 180 volts as the Lower Transfer Voltage press the pushbutton until 2 indicators are flashing To select 196 volts as the Lower Transfer Voltage press the pushbutton until 3 indicators are flashing DuA Once in Programming Mode if the pushbutton is not pressed within 5 seconds the Back UPS will exit the Programming Mode and all indicators will extinguish Back UPS Storage Before storing charge the Back UPS for at least eight hours Store the Back UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 5 to 30 C _ 23 to 86 F Every 6 months 8 hours 30 to 45 C 86 to 113 F Every 3 months 8 hours Please contact APC Technical Support to troubleshoot the unit before returning it to APC Note If the UPS requires service do not return it to the dealer The following steps should be taken pb Consult the Troubleshooting section to eliminate common problems 2 Determine if the circuit breaker is tripped If the circuit breaker is tripped reset the breaker and determine if the problem still exists 3 Ifthe problem persists consult the APC Worldwide Web site www apcc com or call customer service e Record the model number of the UPS the serial number and
14. ust close the box 4 Insert the APC Installation CD ROM into the computer s drive The software user documentation is a file on the main folder of the CD The filename is Users Guide pdf Follow the installation instructions on the computer screen Pi If the software does not automatically install the Windows autorun feature may have been disabled In this case Choose Start in the taskbar and then the Run option Type the following lt CD ROM drive letter gt setup exe Click OK 6 After the installation is complete the APC plug icon will appear in the taskbar near the clock To view the Power Management user interface double click on the APC plug taskbar icon or alternatively choose Start gt Settings gt Control Panel gt Power Management Note Windows 98 and Windows Me categorize a UPS as an HID Human Interface Device The Back UPS is listed in Control Panel gt System gt Device Manager gt HID category gt HID Compliant Device Windows 2000 Users The CD ROM included with this package contains a wizard that optimizes a computer system s power settings for operation with the Back UPS It does this by changing various settings in Power Options Properties in the Control Panel APC strongly advises that the computer system be reconfigured by running this wizard 1 Insert the APC Power Management CD ROM into the computer s drive 2 Choose Start and then t